Loading...
HomeMy WebLinkAboutLA217902-APPROVED - Matthew BraunCity of Lakeville Building Permit ApplicationRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ HOME PHONE _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ INTEREST EARNINGS ON THE ESCROW ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT (Please Print)DATE APPLICANT’S SIGNATURE: www.lakevillemn.gov Submit to: permits@lakevillemn.gov LH - email 9/1/2023 $201.00 RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT DECK FOOTING CONDO FIREPLACE ACESSORY BUILDING FOOTING REROOF FOUNDATION RESIDE FRAMING PORCH FRAMING GARAGES INSULATION RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LATH LOWER LEVEL FINISH LOWER LEVEL FINAL ADDITION OTHER FOUNDATION ONLY PORCH FOOTING MISCELLANEOUS POURED WALL DEMO SEPTIC TANK REMOVAL MOVED SITE MECHANICAL CITY BUILDING VALUATION: $AIR TEST FINAL BUILDING PERMIT FEES ROUGH-IN $PERMIT FEE PLUMBING $PLAN CHECK FINAL $SURCHARGE ROUGH-IN $METRO SAC METER SIZE $CITY WATER HOOKUP UNIT PRESSURE REDUCING VALVE $CITY SEWER HOOKUP UNIT SEWER/WATER $LANDSCAPE ESCROW SEWER/WATER $TREE ESCROW FINAL $MISC ESCROW STREET DRAINTILE $PLUMBING BUILDING INFORMATION $MECHANICAL TYPE OF CONSTRUCTION $SEWER WATER ZONING $OTHER CODE EDITION $TOTAL FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: :(676+25( '(6,*1(1*,1((563& 100 GREAT OAKS BLVD. ͿSUITE 115 ALBANY Ϳ NEW YORK Ϳ 12203 :HVW6KRUH'HVLJQ(QJLQHHUVۅ*UHDW2DNV%OYGۅ6XLWHۅ$OEDQ\1<ۅ  6XEMHFW %UDXQ5HVLGHQFH   'UDIW+RUVH%OYG   /DNHYLOOH01  7R:KRP,W0D\&RQFHUQ  7KHIROORZLQJUHIHUHQFHVWKH%UDXQ5HVLGHQFHLQ/DNHYLOOH01  ([LVWLQJURRIIUDPLQJ 5RRIV3UHIDEULFDWHGHQJLQHHUHGZRRGWUXVVLV[DW´RF7KLVH[LVWLQJVWUXFWXUHLV FDSDEOHRIVXSSRUWLQJDOOWKHORDGVLQGLFDWHGEHORZIRUWKLVSKRWRYROWDLF 5RRI/RDGLQJ SVIGHDGORDG VRODUPRGXOHVSOXVPRXQWLQJKDUGZDUH  SVIJURXQGVQRZORDG SVIURRIPDWHULDOV SVI[SVIVKHDWKLQJSVIDVSKDOWVKLQJOHV  ([SRVXUH&DWHJRU\%PSKZLQG VHF   7KLVLQVWDOODWLRQGHVLJQZLOOEHLQJHQHUDOFRQIRUPDQFHWRWKHPDQXIDFWXUHU¶VVSHFLILFDWLRQVDQGFRPSOLHV ZLWKDOODSSOLFDEOHODZVFRGHVDQGRUGLQDQFHVVSHFLILFDOO\WKH,QWHUQDWLRQDO%XLOGLQJ&RGH,%& DQG,QWHUQDWLRQDO5HVLGHQWLDO&RGH,5&LQFOXGLQJDOO01UHJXODWLRQVDQGDPHQGPHQWV7KHVSDFLQJ DQGIDVWHQLQJRIWKHPRXQWLQJEUDFNHWVLVWRKDYHDPD[LPXPRI´RFVSDQEHWZHHQPRXQWLQJEUDFNHWV VWDJJHUHGDQGVHFXUHGXVLQJ´GLDPHWHUFRUURVLYHUHVLVWDQWVWHHOODJEROWVDQGD´HPEHG6QDS1 5DFN6SHHGVHDOGHFNDWWDFKPHQWVRULQGXVWU\VLPLODULQOLHXRI/IRRWDQFKRUVLQVWDOOHGSHUPDQXIDFWXUHU VSHFLILFDWLRQVDQGUHFRPPHQGDWLRQV  7KDQN\RX  :HVWVKRUH'HVLJQ(QJLQHHUV  ,KHUHE\FHUWLI\WKDWWKLVSODQVSHFLILFDWLRQRUUHSRUWZDVSUHSDUHGE\PHRUXQGHUP\GLUHFWVXSHUYLVLRQ DQGWKDW,DPGXO\/LFHQVHG3URIHVVLRQDO(QJLQHHUXQGHUWKHODZVRIWKHVWDWHRI0LQQHVRWD   6LJQDWXUHBBBBBBBBBBBBBBBBBBBB 1DPH1LFRODV1LWWL 'DWH /LFHQVH1XPEHU -RKQ(LEHUW1LFRODV1LWWL3( 3URMHFW&RRUGLQDWRU3UHVLGHQW 7R $OO(QHUJ\6RODU  '0DLQOLQH'U  :HVWILHOG0$  'DWH$XJXVW 5HI  DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE-LINE DIAGRAM PV-4 PV SAFETY LABELS PV-5.1-4 ATTACHMENT PLANS PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN APPENDIXANCHOR DATASHEET ARRAY WIRING BOX DATASHEETS DISCONNECT DATASHEET INVERTER DATASHEET MODULE DATASHEET MOUNTING SYSTEM DATASHEET MOUNTING SYSTEM ENGINEERING LETTER UL 2703 CLASS A FIRE CERTIFICATION UL 2703 GROUNDING AND BONDING CERTIFICATION PROJECT DETAILS PROPERTY OWNER MATTHEW J & CHRISTINA M BRAUN PROPERTY ADDRESS 16389 DRAFT HORSE BLVD, LAKEVILLE, MN 55044 APN 227134402130 ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) AHJ CITY OF LAKEVILLE UTILITY COMPANY DAKOTA ELECTRIC ASSOCIATION METER SERIAL NUMBER 1ND90305577 ELECTRICAL CODE 2020 NEC (NFPA 70) FIRE CODE 2018 IFC OTHER BUILDING CODES 2020 MN BUILDING CODE 2020 MN RESIDENTIAL CODE 2020 MN PLUMBING CODE 2020 MN MECHANICAL CODE SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A GRID- INTERACTIVE PV SYSTEM. PV MODULES WILL BE MOUNTED USING A PREENGINEERED MOUNTING SYSTEM. THE MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED TO DESCRIBE THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO ENERGY STORAGE DC RATING OF SYSTEM 13.44KW AC OUTPUT RATINGS 10.08KW, 41.9A INVERTER(S)32 X ENPHASE IQ7X-96-2-US MODULE(S)32 X REC SOLAR REC420AA PURE-R ARRAY WIRING (2) BRANCH OF 11 IQ7X-96-2-US MICROINVERTERS (1) BRANCH OF 10 IQ7X-96-2-US MICROINVERTERS INTERCONNECTION DETAILS POINT OF INTERCONNECTION NEW SUPPLY SIDE AC CONNECTION PER NEC 705.11 UTILITY SERVICE 120/240V 1Φ UTILITY METER FUSED EATON DG222NRB DISCONNECT, 2-POLE, 60A, 240VAC SITE DESIGN PARAMETERS ASHRAE EXTREME LOW -29°C (-20°F) ASHRAE 2% HIGH 32°C (90°F) CLIMATE DATA SOURCE AIRLAKE AIRPORT WIND (ASCE 7-16)109 MPH, EXPOSURE CATEGORY B, RISK CATEGORY II GROUND SNOW LOAD 50 PSF 48401 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 GRID-TIED PV SYSTEMM. BRAUN16389 DRAFT HORSE BLVDLAKEVILLE, MN 55044PROJECT SUMMARY DOC ID:DDBF73-1 DATE:8/30/23 CREATOR:A.F. REVIEWER: REVISIONS PV-1 Account: 200010042605 Meter: 1ND90305577 Premise: 124029 Concept Approval ONLY Subject to Field Inspection Inspector Date 2015 MN Bldg Code 09/13/2023jnuetzman DISTANCE TO NEAREST CROSS STREET FROM ADDRESS DRYDEN ROAD PROJECT INFORMATION CONTRACTOR NAME ALL ENERGY SOLAR CONTRACTOR PHONE (800) 620-3370 GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MIN. WORKING CLEARANCES PER NEC 110.26. 2 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL DAKOTA ELECTRIC ASSOCIATION EQUIPMENT. 3 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 4 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. 5 ALL EXPOSED PV ROOFTOP CONDUCTORS NOT UNDER THE ARRAY SHALL BE PROTECTED BY A RACEWAY WITH A LISTED JUNCTION BOX AT BOTH ENDS AND COMPLY WITH NEC 690.31(A). 6 ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS WEATHERPROOF FITTINGS AND INSTALLED TO ENSURE A RAINTIGHT FIT, PER NEC 358.42. 7 SITE SHALL MEET NESC CLEARANCE REQUIREMENTS (E) MAIN SERVICE PANEL (MSP), INDOOR (N) READILY ACCESSIBLE PRODUCTION METER LOCATED WITHIN 10 FT OF UTILITY METER (M2), OUTDOOR (N) VISIBLE-OPEN TYPE, LOCKABLE, READILYACCESSIBLE, LABELED UTILITY PV DISCONNECTLOCATED WITHIN 10 FT OF UTILITY METER (SW1),OUTDOOR (N) AC COMBINER (C1), OUTDOOR (E) UTILITY METER, OUTDOOR (N) TRANSITION BOX, OUTDOOR, OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN EMT CONDUIT THROUGH THE INTERIOR OF THE BUILDING (N) PROPOSED ROOF-MOUNTED PV ARRAY. 10/12 (39.8°) SLOPED ROOF, (8) REC SOLAR REC420AA PURE-R MODULES (BLACK FRAME, BLACK BACKSHEET), 90° AZIMUTH (N) PROPOSED ROOF-MOUNTED PV ARRAY. 12/12 (45.0°) SLOPED ROOF, (3) REC SOLAR REC420AA PURE-R MODULES (BLACK FRAME, BLACK BACKSHEET), 180° AZIMUTH (N) PROPOSED ROOF-MOUNTED PV ARRAY. 10/12 (39.8°) SLOPED ROOF, (12) REC SOLAR REC420AA PURE-R MODULES (BLACK FRAME, BLACK BACKSHEET), 180° AZIMUTH (N) PROPOSED ROOF-MOUNTED PV ARRAY. 10/12 (39.8°) SLOPED ROOF, (9) REC SOLAR REC420AA PURE-R MODULES (BLACK FRAME, BLACK BACKSHEET), 90° AZIMUTH ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. 48401 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 GRID-TIED PV SYSTEMM. BRAUN16389 DRAFT HORSE BLVDLAKEVILLE, MN 55044SITE PLAN DOC ID:DDBF73-1 DATE:8/30/23 CREATOR:A.F. REVIEWER: REVISIONS PV-2 Account: 200010042605Meter: 1ND90305577 Premise: 124029 PV MODULE MICRO- INVERTER PM1-32 420W 11 IN BRANCH 10 IN BRANCH 11 IN BRANCH 21 1 1 2 3 4 5 6 7 JUNCTION BOXES 4 3 5 JB1-2 AC COMBINER COMM GATEWAY C1CB3 20A 6 CB1 20A CB2 20A 8 9 PoC RPA PoC RPA NN UTILITY PV DISCONNECT EATON DG222NRB SW1 60A 7 F1-2 60A 10 11 UTILITY METER LOAD KWHRKWHR GENERATIONMETER LINE KWHR LOAD LINE KWHR LOAD LINE (E) ACGEC S/N: 1ND90305577 120/240V 1ɸ, 3W (200A MSP W/200A MCB) 8 12 MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-32 32 REC SOLAR REC420AA PURE-R 420W 402W 8.89A 8.40A 59.4V 50.0V -0.1408V/°C (-0.24%/°C)25A INVERTERS REF.QTY .MAKE AND MODEL AC VOLTAGE GROUND RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-32 32 ENPHASE IQ7X-96-2-US 240V NOT SOLIDLY GROUNDED 315W 1.31A 10.0A 80V 97.5% DISCONNECTS REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 EATON DG222NRB OR EQUIV.60A 240VAC OCPDS REF.QTY.RATED CURRENT MAX VOLTAGE CB1-3 3 20A 240VAC F1-2 2 60A 240VAC PASS-THRU BOXES AND COMBINERS REF.QTY .MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE JB1-2 2 SOLADECK 0799-5 WITH 01611 KIT OR EQUIV.30A 240VAC / 600VDC C1 1 ENPHASE IQ COMBINER 4 W/ IQ GATEWAY FOR PRODUCTION MONITORING 64A 240VAC SYSTEM SUMMARY BRANCH 1 BRANCH 2 BRANCH 3 INVERTERS PER BRANCH 11 10 11 MAX AC CURRENT 14.41A 13.10A 14.41A MAX AC OUTPUT 3,465W 3,150W 3,465W ARRAY STC POWER 13,440W ARRAY PTC POWER 12,880W MAX AC CURRENT 41.92A MAX AC POWER OUTPUT 10,080W DERATED AC POWER OUTPUT 10,080W RAPID SHUTDOWN DEVICES COMPLIANT WITH REQUIREMENTS AS PER NEC 690.12(B)(2). PV CIRCUIT CONDUCTORS LOCATED OUTSIDE THE ARRAY BOUNDARY (DEFINED AS 3 FEET FROM THE POINT OF PENETRATION INTO A BUILDING OR MORE THAN 3 FEET FROM AN ARRAY) SHALL BE LIMITED TO NOT MORE THAN 30V WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION. CONDUCTORS LOCATED INSIDE OF THE ARRAY BOUNDARY SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS WITHIN 30 SECONDS OF SHUTDOWN. 1 ENPHASE SYSTEM MEETS REQUIREMENTS FOR PV HAZARD CONTROL SYSTEM, AS PER NEC 690.12(B)(2).2 THE DC AND AC CONNECTORS OF THE ENPHASE IQ7X-96-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(C). MATING CONNECTORS SHALL COMPLY WITH NEC 690.33.3 THE ENPHASE IQ7X-96-2-US HAS A CLASS II DOUBLE-INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS (EGC). THE RATING INCLUDES GROUND FAULT PROTECTION (GFP). TO SUPPORT GFP, USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV WIRE OR PV CABLE.4 MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL 3003 AND UL 9703.5 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND PART III OF ARTICLE 250 AND DC EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A) AND NEC 250.169 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. 6 MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 67.0V AT -29°C (-28.9°C - 25°C) X -0.141V/C + 59.4V = 67.0V).7 AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH NEC 705.12(B)(3)(3).8 THE ENPHASE IQ COMBINER 4 CONTAINS A FACTORY-INSTALLED COMMUNICATIONS GATEWAY WITH AN OCPD RATED NO MORE THAN 20A.9 UTILITYPV DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY IN ACCORDANCE WITH NEC 690.13(E). THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER AND INSTALLED IN COMPLIANCE WITH NEC 705.20 AND GROUPED AS REQUIRED BY NEC 230.72. GROUNDED CONDUCTOR SHALL BONDED INSIDE DISCONNECT PER NEC 250.24(B) AND NEC 250.24(C) AS REQUIRED BY NEC 250.25. 10 11 UTILITY PV DISCONNECT MEETS NEC 690.12(C) REQUIREMENT FOR A RAPID SHUTDOWN INITIATION DEVICE POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT, AT METER BASE TERMINALS THAT ARE SUITABLE FOR DOUBLE LUGGING OR USING ANOTHER LOCALLY-APPROVED METHOD, IN COMPLIANCE WITH NEC 705.11.12 ALL AC EQUIPMENT SHALL BE 3-WIRE, SINGLE-PHASE 120/240 V.13 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYP CONDUCTOR CONDUIT / CABLE CURRENT-CARRYING CONDUCTORS IN CONDUIT/CABLE. OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP.DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING LEN. V.D. 1 2 10 AWG THHN/THWN-2 IN ENPHASE Q CABLE, COPPER CABLE 2 20A 10 AWG BARE, COPPER 0.76 (54°C)1.0 14.41A 18.01A 30A 23A 90°C 30A 144.4FT 1.71% 2 1 10 AWG THHN/THWN-2 IN ENPHASE Q CABLE, COPPER CABLE 2 20A 10 AWG BARE, COPPER 0.76 (54°C)1.0 13.1A 16.38A 30A 23A 90°C 30A 65.6FT 1.42% 3 1 10 AWG THWN-2, COPPER 0.75" DIA. EMT 2 20A 10 AWG THWN-2, COPPER 0.76 (52°C)1.0 14.41A 18.01A 40A 30.4A 90°C 40A 103.3FT 1.54% 4 1 10 AWG THWN-2, COPPER 0.75" DIA. EMT 4 20A 10 AWG THWN-2, COPPER 0.76 (52°C)0.8 13.1A 16.38A 40A 24.32A 90°C 40A 78.7IN 0.09% 5 1 10 AWG THWN-2, COPPER 0.75" DIA. EMT 4 20A 10 AWG THWN-2, COPPER 0.76 (52°C)0.8 14.41A 18.01A 40A 24.32A 90°C 40A 78.7IN 0.1% 6 1 6 AWG THWN-2, COPPER 0.75" DIA. EMT 2 60A 10 AWG THWN-2, COPPER 0.96 (32°C)1.0 41.92A 52.4A 75A 72A 75°C 65A 48IN 0.07% 7 1 6 AWG THWN-2, COPPER 0.75" DIA. EMT 2 60A 10 AWG THWN-2, COPPER 0.96 (32°C)1.0 41.92A 52.4A 75A 72A 75°C 65A 48IN 0.07% 8 1 6 AWG THWN-2, COPPER 1.0" DIA. PVC-80 2 60A N/A 0.96 (32°C)1.0 41.92A 52.4A 75A 72A 75°C 65A 48IN 0.07% REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE: SCALE:GRID-TIED PV SYSTEMLAKEVILLE, MN 5504416389 DRAFT HORSE BLVDPV-3 48401 8/30/23 A.F. DDBF73-1 SINGLE-LINE DIAGRAMM. BRAUN 1 PV-3 SINGLE-LINE DIAGRAM NTS 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 5 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 6 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 3 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). Account: 200010042605 Meter: 1ND90305577 Premise: 124029 PV MODULEMICRO-INVERTERPM1-32420W11 INBRANCH10 INBRANCH11 INBRANCH2111234567JUNCTION BOXES435JB1-2AC COMBINERCOMMGATEWAYCB3 C120A6CB120ACB220A89PoCPoCRPARPANNUTILITY PV DISCONNECT EATON DG222NRBSW160A7F1-260A1011UTILITY METERLOADKWHRKWHR GENERATIONMETERLINEKWHRKWHRLOADLOADLINELINE(E) AC GECS/N: 1ND90305577120/240V 1ɸ, 3W(200A MSP W/200A MCB)812CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYP CONDUCTOR CONDUIT / CABLE CURRENT-CARRYING CONDUCTORS IN CONDUIT/CABLE. OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP.DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING LEN. V.D. 1 2 10 AWG THHN/THWN-2 IN ENPHASE Q CABLE, COPPER CABLE 2 20A 10 AWG BARE, COPPER 0.76 (54°C)1.0 14.41A 18.01A 30A 23A 90°C 30A 144.4FT 1.71% 2 1 10 AWG THHN/THWN-2 IN ENPHASE Q CABLE, COPPER CABLE 2 20A 10 AWG BARE, COPPER 0.76 (54°C)1.0 13.1A 16.38A 30A 23A 90°C 30A 65.6FT 1.42% 3 1 10 AWG THWN-2, COPPER 0.75" DIA. EMT 2 20A 10 AWG THWN-2, COPPER 0.76 (52°C)1.0 14.41A 18.01A 40A 30.4A 90°C 40A 103.3FT 1.54% 4 1 10 AWG THWN-2, COPPER 0.75" DIA. EMT 4 20A 10 AWG THWN-2, COPPER 0.76 (52°C)0.8 13.1A 16.38A 40A 24.32A 90°C 40A 78.7IN 0.09% 5 1 10 AWG THWN-2, COPPER 0.75" DIA. EMT 4 20A 10 AWG THWN-2, COPPER 0.76 (52°C)0.8 14.41A 18.01A 40A 24.32A 90°C 40A 78.7IN 0.1% 6 1 6 AWG THWN-2, COPPER 0.75" DIA. EMT 2 60A 10 AWG THWN-2, COPPER 0.96 (32°C)1.0 41.92A 52.4A 75A 72A 75°C 65A 48IN 0.07% 7 1 6 AWG THWN-2, COPPER 0.75" DIA. EMT 2 60A 10 AWG THWN-2, COPPER 0.96 (32°C)1.0 41.92A 52.4A 75A 72A 75°C 65A 48IN 0.07% 8 1 6 AWG THWN-2, COPPER 1.0" DIA. PVC-80 2 60A N/A 0.96 (32°C)1.0 41.92A 52.4A 75A 72A 75°C 65A 48IN 0.07% AC COMBINER SW1 - DISCONNECT (EATON DG222NRB) UTILITY METER MAIN SERVICE PANEL SEE NOTE NO. 4 (SW1, MSP) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. NEC 690.56(C)(1) AND IFC 1204.5.1 AC COMBINER PANEL (C1) ! WARNING ! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. NEC 705.12(B)(3)(3) POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT (MSP, UM) ! CAUTION: MULTIPLE SOURCES OF POWER ! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF-MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN 16389 DRAFT HORSE BLVD, LAKEVILLE • INSTALLED BY ALL ENERGY SOLAR • (800) 620-3370 NEC 690.56(B) AND NEC 705.10 SEE NOTE NO. 5 (SW1) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM NEC 690.56(C)(3) AND IFC 1204.5.3 AC DISCONNECT (SW1) MAXIMUM AC OPERATING CURRENT: 41.9A MAXIMUM AC OPERATING VOLTAGE: 240V NEC 690.54 EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (SW1) ! WARNING ! ELECTRIC SHOCK HAZARD. TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NEC 690.13(B) PV SYSTEM DISCONNECT (SW1) PV SYSTEM DISCONNECT NEC 690.13(B) ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (SW1, MSP) ! CAUTION ! MULTIPLE SOURCES OF POWER NEC 705.10 LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2020 NEC AND 2018 IFC WILL BE INSTALLED AS REQUIRED. 2 LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC 110.21(B). 3 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). 4 LABEL(S) WITH MARKING, "TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY," SHALL BE LOCATED WITHIN 3 FT OF SERVICE DISCONNECTING MEANS THE TITLE SHALL UTILIZE CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8″ IN BLACK ON A YELLOW BACKGROUND, AND REMAINING TEXT SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16″ IN BLACK ON WHITE BACKGROUND. 5 LABEL(S) WITH MARKING, "RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM," SHALL BE LOCATED WITHIN 3 FT OF RAPID SHUTDOWN SWITCH. THE LABEL SHALL HAVE 3/8″ TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND. 48401 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 GRID-TIED PV SYSTEMM. BRAUN16389 DRAFT HORSE BLVDLAKEVILLE, MN 55044SAFETY LABELS DOC ID:DDBF73-1 DATE:8/30/23 CREATOR:A.F. REVIEWER: REVISIONS PV-4 Account: 200010042605 Meter: 1ND90305577 Premise: 124029 AC COMBINER SERVICE DISCONNECT (INSIDE) UTILITY PV/PV SERVICE DISCONNECT STRUCTURAL DESIGN PARAMETERS ELEVATION 937 FT SEISMIC 0.051 SDS WIND (ASCE 7-16)109 MPH, EXPOSURE CATEGORY B, RISK CATEGORY II GROUND SNOW LOAD 50 PSF ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 10/12 (39.8°) MEAN ROOF HEIGHT 17FT ROOF DECKING 15/32" OSB CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL REC SOLAR REC420AA PURE-R DIMENSIONS (AREA) 68.1IN X 44.0IN X 1.2IN (20.8 SQ FT) WEIGHT 47.4 LBS MOUNTING SYSTEM PROPERTIES RAIL MODEL SNAPNRACK UR-40 ANCHOR MODEL SNAPNRACK 242-02174 (FLASHED), 4.5IN AIR GAP FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES OR DECKING WITH (4) 1/4IN DIA. FASTENERS GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 9 47.4 426.6 MICROINVERTERS 9 2.4 21.4 LINEAR FEET OF RAIL 69 FT 0.4 29.0 ANCHORS 28 0.6 18.2 MISC. HARDWARE 7.1 7.1 TOTAL ARRAY WEIGHT 502.3 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 9 20.8 187.2 POINT LOAD (502.3 LBS / 28 ATTACHMENTS) 17.9 LBS DIST. LOAD (502.3 LBS / 187.2 SQFT)2.68 PSF NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ANCHORS MAY BE FASTENED TO DECKING WHERE NEEDED. IN NO CASE SHALL THE ANCHOR SPACING EXCEED "MAX. ANCHOR SPACING" ANCHOR PLACEMENT PARAMETERS (ASCE 7-16) WIND PRESSURE ZONE MODULE WIND EXPOSURE MAX. ALLOWABLE RAIL SPAN MAX. ANCHOR SPACING MAX. ALLOWABLE CANTILEVER ZONES 1, 2N, 2R, 3E, 3R NORMAL 48.0IN 48.0IN 16.3IN DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION ("LHD") OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LHD OR 3 FT. THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ROOF PLANES IN ACCORDANCE WITH GUIDANCE PROVIDED BY ASCE 7-16 FIGURES 30.3-2B–I. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT) 5.3 FT = MAX(MIN(0.4 * 17.0 FT, 0.1 * 53.2 FT), 0.04 * 53.2 FT, 3 FT) 48401 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 GRID-TIED PV SYSTEMM. BRAUN16389 DRAFT HORSE BLVDLAKEVILLE, MN 55044ATTACHMENT PLAN DOC ID:DDBF73-1 DATE:8/30/23 CREATOR:A.F. REVIEWER: REVISIONS PV-5.1 18" ≈3" ≈3" STRUCTURAL DESIGN PARAMETERS ELEVATION 937 FT SEISMIC 0.051 SDS WIND (ASCE 7-16)109 MPH, EXPOSURE CATEGORY B, RISK CATEGORY II GROUND SNOW LOAD 50 PSF ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 12/12 (45.0°) MEAN ROOF HEIGHT 17.3FT ROOF DECKING 15/32" OSB CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL REC SOLAR REC420AA PURE-R DIMENSIONS (AREA) 68.1IN X 44.0IN X 1.2IN (20.8 SQ FT) WEIGHT 47.4 LBS MOUNTING SYSTEM PROPERTIES RAIL MODEL SNAPNRACK UR-40 ANCHOR MODEL SNAPNRACK 242-02174 (FLASHED), 4.5IN AIR GAP FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES OR DECKING WITH (4) 1/4IN DIA. FASTENERS GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 3 47.4 142.2 MICROINVERTERS 3 2.4 7.1 LINEAR FEET OF RAIL 23 FT 0.4 9.7 ANCHORS 10 0.6 6.5 MISC. HARDWARE 2.6 2.6 TOTAL ARRAY WEIGHT 168.1 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 3 20.8 62.4 POINT LOAD (168.1 LBS / 10 ATTACHMENTS) 16.8 LBS DIST. LOAD (168.1 LBS / 62.4 SQFT)2.69 PSF NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ANCHORS MAY BE FASTENED TO DECKING WHERE NEEDED. IN NO CASE SHALL THE ANCHOR SPACING EXCEED "MAX. ANCHOR SPACING" ANCHOR PLACEMENT PARAMETERS (ASCE 7-16) WIND PRESSURE ZONE MODULE WIND EXPOSURE MAX. ALLOWABLE RAIL SPAN MAX. ANCHOR SPACING MAX. ALLOWABLE CANTILEVER ZONES 2N, 2R, 3R NORMAL 48.0IN 48.0IN 16.3IN DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION ("LHD") OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LHD OR 3 FT. THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ROOF PLANES IN ACCORDANCE WITH GUIDANCE PROVIDED BY ASCE 7-16 FIGURES 30.3-2B–I. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT) 5.3 FT = MAX(MIN(0.4 * 17.3 FT, 0.1 * 53.2 FT), 0.04 * 53.2 FT, 3 FT) 48401 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 GRID-TIED PV SYSTEMM. BRAUN16389 DRAFT HORSE BLVDLAKEVILLE, MN 55044ATTACHMENT PLAN DOC ID:DDBF73-1 DATE:8/30/23 CREATOR:A.F. REVIEWER: REVISIONS PV-5.2 ≈3" 18" STRUCTURAL DESIGN PARAMETERS ELEVATION 937 FT SEISMIC 0.051 SDS WIND (ASCE 7-16)109 MPH, EXPOSURE CATEGORY B, RISK CATEGORY II GROUND SNOW LOAD 50 PSF ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 10/12 (39.8°) MEAN ROOF HEIGHT 17FT ROOF DECKING 15/32" OSB CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL REC SOLAR REC420AA PURE-R DIMENSIONS (AREA) 68.1IN X 44.0IN X 1.2IN (20.8 SQ FT) WEIGHT 47.4 LBS MOUNTING SYSTEM PROPERTIES RAIL MODEL SNAPNRACK UR-40 ANCHOR MODEL SNAPNRACK 242-02174 (FLASHED), 4.5IN AIR GAP FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES OR DECKING WITH (4) 1/4IN DIA. FASTENERS GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 12 47.4 568.8 MICROINVERTERS 12 2.4 28.6 LINEAR FEET OF RAIL 91 FT 0.4 38.3 ANCHORS 30 0.6 19.5 MISC. HARDWARE 7.3 7.3 TOTAL ARRAY WEIGHT 662.5 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 12 20.8 249.6 POINT LOAD (662.5 LBS / 30 ATTACHMENTS) 22.1 LBS DIST. LOAD (662.5 LBS / 249.6 SQFT)2.65 PSF NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ANCHORS MAY BE FASTENED TO DECKING WHERE NEEDED. IN NO CASE SHALL THE ANCHOR SPACING EXCEED "MAX. ANCHOR SPACING" ANCHOR PLACEMENT PARAMETERS (ASCE 7-16) WIND PRESSURE ZONE MODULE WIND EXPOSURE MAX. ALLOWABLE RAIL SPAN MAX. ANCHOR SPACING MAX. ALLOWABLE CANTILEVER ZONES 1, 2E, 2N, 2R, 3E, 3R NORMAL 48.0IN 48.0IN 16.3IN DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION ("LHD") OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LHD OR 3 FT. THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ROOF PLANES IN ACCORDANCE WITH GUIDANCE PROVIDED BY ASCE 7-16 FIGURES 30.3-2B–I. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT) 5.3 FT = MAX(MIN(0.4 * 17.0 FT, 0.1 * 53.2 FT), 0.04 * 53.2 FT, 3 FT) 48401 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 GRID-TIED PV SYSTEMM. BRAUN16389 DRAFT HORSE BLVDLAKEVILLE, MN 55044ATTACHMENT PLAN DOC ID:DDBF73-1 DATE:8/30/23 CREATOR:A.F. REVIEWER: REVISIONS PV-5.3 18" ≈3" STRUCTURAL DESIGN PARAMETERS ELEVATION 937 FT SEISMIC 0.051 SDS WIND (ASCE 7-16)109 MPH, EXPOSURE CATEGORY B, RISK CATEGORY II GROUND SNOW LOAD 50 PSF ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 10/12 (39.8°) MEAN ROOF HEIGHT 15.9FT ROOF DECKING 15/32" OSB CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL REC SOLAR REC420AA PURE-R DIMENSIONS (AREA) 68.1IN X 44.0IN X 1.2IN (20.8 SQ FT) WEIGHT 47.4 LBS MOUNTING SYSTEM PROPERTIES RAIL MODEL SNAPNRACK UR-40 ANCHOR MODEL SNAPNRACK 242-02174 (FLASHED), 4.5IN AIR GAP FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES OR DECKING WITH (4) 1/4IN DIA. FASTENERS GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 8 47.4 379.2 MICROINVERTERS 8 2.4 19.0 LINEAR FEET OF RAIL 93 FT 0.4 39.2 ANCHORS 32 0.6 20.8 MISC. HARDWARE 6.0 6.0 TOTAL ARRAY WEIGHT 464.3 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 8 20.8 166.4 POINT LOAD (464.3 LBS / 32 ATTACHMENTS) 14.5 LBS DIST. LOAD (464.3 LBS / 166.4 SQFT)2.79 PSF NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ANCHORS MAY BE FASTENED TO DECKING WHERE NEEDED. IN NO CASE SHALL THE ANCHOR SPACING EXCEED "MAX. ANCHOR SPACING" ANCHOR PLACEMENT PARAMETERS (ASCE 7-16) WIND PRESSURE ZONE MODULE WIND EXPOSURE MAX. ALLOWABLE RAIL SPAN MAX. ANCHOR SPACING MAX. ALLOWABLE CANTILEVER ZONES 1, 2E, 2N, 2R, 3E, 3R NORMAL 48.0IN 48.0IN 16.3IN DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION ("LHD") OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LHD OR 3 FT. THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ROOF PLANES IN ACCORDANCE WITH GUIDANCE PROVIDED BY ASCE 7-16 FIGURES 30.3-2B–I. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT) 5.3 FT = MAX(MIN(0.4 * 15.9 FT, 0.1 * 53.2 FT), 0.04 * 53.2 FT, 3 FT) 48401 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 GRID-TIED PV SYSTEMM. BRAUN16389 DRAFT HORSE BLVDLAKEVILLE, MN 55044ATTACHMENT PLAN DOC ID:DDBF73-1 DATE:8/30/23 CREATOR:A.F. REVIEWER: REVISIONS PV-5.4 18" ≈3" REC 420 BOB REC420AA PURE-R Drive Link L= 68.10” W= 44” D= 1.20” Weight= 47.4 lbs Short Side Mounting - Yes L 20.4”11.41” S 7.9” 11.8” 48401 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 GRID-TIED PV SYSTEMM. BRAUN16389 DRAFT HORSE BLVDLAKEVILLE, MN 55044ATTACHMENT DETAILS DOC ID:DDBF73-1 DATE:8/30/23 CREATOR:A.F. REVIEWER: REVISIONS PV-6 GENERAL NOTES 1 AT LEAST TWO 3′-WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS, WITH AT LEAST ONE PATHWAY ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PV ARRAY, AT LEAST ONE SUCH PATHWAY FROM LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE, OR ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. (IFC 1204.2.1.1) 2 FOR PV ARRAYS OCCUPYING 33% OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A MIN. 18″-WIDE SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. (IFC 1204.2.1.2) 3 PV MODULES SHALL NOT BE PLACED BELOW AN EMERGENCY ESCAPE/RESCUE OPENING. A 3′-WIDE PATHWAY SHALL BE PROVIDED TO SUCH AN OPENING. (IFC 1204.2.2) 4 ROOF FACES WITH NO PV ARE DESIGNATED FOR FIRE VENTILATION AND ACCESS 1.5′ WIDE SMOKE-VENTILATION SETBACK, PER IFC 1204.2.1.2 PV MODULES INSTALLED ON ROOF WITH SNAPNRACK ULTRA RAIL MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 2703 CLASS A FIRE RATED ON THIS STEEP-SLOPED ROOF WHEN INSTALLED WITH TYPE 1 OR 2 MODULES. THE REC SOLAR REC420AA PURE-R IS UL 61730-1 CERTIFIED TYPE 2. 3.0′ WIDE FIRE ACCESS PATHWAY, PER IFC 1204.2.1.1 ROOF ACCESS POINT BUILDING IS 1-STORY, GROUP R3 TOTAL PLAN VIEW ARRAY AREA IS 507.9 SQ.FT, WHICH REPRESENTS 20.9% OF TOTAL PLAN VIEW ROOF AREA (2432.9 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS. THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. 48401 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 GRID-TIED PV SYSTEMM. BRAUN16389 DRAFT HORSE BLVDLAKEVILLE, MN 55044FIRE SAFETY PLAN DOC ID:DDBF73-1 DATE:8/30/23 CREATOR:A.F. REVIEWER: REVISIONS PV-7 COMPACT PANEL Size9 A module Current compatible with MLPErec Alpha Pure-R SERIESProduct Specificationsα experienceperformancewp43020.7w ft2ELIGIBLELEAD-FREErohs cOMPLIANT22.3%Efficiency Ref: PM-DS-12-06-Rev- B 08.22www.recgroup.comGENERAL DATACell type:80 half-cut REC bifacial, heterojunction cells with lead-free, gapless technologyGlass:0.13 in (3.2 mm) solar glass with anti-reflective surface treatment in accordance with EN 12150Backsheet:Highly resistant polymer (black)Frame:Anodized aluminum (black)Junction box:4-part, 4 bypass diodes, lead-free IP68 rated, in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4 (4 mm²) in accordance with IEC 62852, IP68 only when connectedCable:12 AWG (4 mm²) PV wire, 67 + 67 in (1.7 + 1.7 m) in accordance with EN 50618Dimensions:68.1 x 44.0 x 1.2 in (20.77 ft2) / 1730 x 1118 x 30 mm (1.93 m2)Weight:47.4 lbs (21.5 kg)Origin:Made in SingaporeSpecifications subject to change without notice.Measurements in inches [mm]LOW LIGHT BEHAVIOURTypical low irradiance performance of module at STC:WARRANTYStandardREC ProTrustInstalled by an REC Certified Solar ProfessionalNoYesYesSystem Size All≤25 kW25-500 kWProduct Warranty (yrs)202525Power Warranty (yrs)252525Labor Warranty (yrs)02510Power in Year 198%98%98%Annual Degradation0.25%0.25%0.25%Power in Year 2592%92%92%See warranty documents for details. Conditions apply Irradiance (W/m²)Rel. Efficiency (%)TEMPERATURE RATINGS*Nominal Module Operating Temperature:44°C (±2°C)Temperature coefficient of PMAX:-0.26 %/°CTemperature coefficient of VOC:-0.24 %/°CTemperature coefficient of ISC:0.04 %/°C*The temperature coefficients stated are linear valuesCERTIFICATIONSIEC 61215:2016, IEC 61730:2016, UL 61730IEC 62804PIDIEC 61701 Salt MistIEC 62716Ammonia ResistanceUL 61730Fire Type Class 2IEC 62782 Dynamic Mechanical LoadIEC 61215-2:2016Hailstone (35mm)IEC 62321Lead-free acc. to RoHS EU 863/2015ISO 14001, ISO 9001, IEC 45001, IEC 62941MAXIMUM RATINGSOperational temperature:-40 ... +85°CSystem voltage:1000 VTest load (front): + 7000 Pa (146 lbs/ft2)*Test load (rear):- 4000 Pa (83.5 lbs/ft2)*Series fuse rating:25 AReverse current:25 A* See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) STC NMOTFounded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific.8590951001052001003004005006007008009001000Lead-FreeELECTRICAL DATAProduct Code*: RECxxxAA PURE-RPower Output - PMAX (Wp) 400410420430Watt Class Sorting - (W)0/+100/+100/+100/+10Nominal Power Voltage - VMPP (V) 48.849.450.050.5Nominal Power Current - IMPP (A) 8.208.308.408.52Open Circuit Voltage - VOC (V) 58.959.259.459.7Short Circuit Current - ISC (A) 8.738.818.898.97Power Density (W/ft2)19.2619.7420.2220.7Panel Efficiency (%) 20.721.221.822.3Power Output - PMAX (Wp)305312320327Nominal Power Voltage - VMPP (V) 46.046.647.147.6Nominal Power Current - IMPP (A) 6.646.706.786.88Open Circuit Voltage - VOC (V) 55.555.856.056.3Short Circuit Current - ISC (A) 7.057.127.187.24Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above.GR GRGR GRGR11±0.2[0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5[0.8±0.02]6.0±0.2[0.24±0.01]1700 [67]1700 [67]Lorem ipsum1730±2.5 [68.1±0.1]880 [34.6]425 [16.7]1077±2.5 [42.4±0.1]22.5 [0.9] 594±3 [23.4±0.12] 1118±2.5 [44.0±0.1]17 [0.7]45 [1.8] 30 [1.2]DELIVERY INFORMATIONPanels per pallet:33Panels per 40 ft GP/high cube container:858 (26 pallets)Panels per 53 ft truck:858 (26 pallets)REC Alpha PURE-R Series Product SPECIFICATIONSAvailable from: The high-powered smart grid-ready Enphase IQ 7X Micro™ dramatically simplifies the installation process while achieving the highest system efficiency for systems with 96-cell modules.Part of the Enphase IQ System, the IQ 7X Micro integrates with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software.The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7X MicroinverterTo learn more about Enphase offerings, visit enphase.comData SheetEnphase MicroinvertersRegion: AMERICASEasy to Install• Lightweight and simple• Faster installation with improved, lighter two-wire cabling• Built-in rapid shutdown compliant (NEC 2014 & 2017)Efficient and Reliable• Optimized for high powered 96-cell* modules• Highest CEC efficiency of 97.5%• More than a million hours of testing• Class II double-insulated enclosure• UL listedSmart Grid Ready• Complies with advanced grid support, voltage and frequency ride-through requirements• Remotely updates to respond to changing grid requirements• Configurable for varying grid profiles• Meets CA Rule 21 (UL 1741-SA)* The IQ 7X is required to support 96-cell modules.1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.To learn more about Enphase offerings, visit enphase.com© 2019 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2019-3-26INPUT DATA (DC)IQ7X-96-2-USCommonly used module pairings¹320 W - 460 W +Module compatibility96-cell PV modulesMaximum input DC voltage79.5 VPeak power tracking voltage53 V - 64 VOperating range25 V - 79.5 VMin/Max start voltage33 V / 79.5 VMax DC short circuit current (module Isc)10 AOvervoltage class DC portIIDC port backfeed current0 APV array configuration1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC)@ 240 VAC@ 208 VACPeak output power320 VAMaximum continuous output power315 VANominal (L-L) voltage/range²240 V / 211-264 V208 V / 183-229 VMaximum continuous output current1.31 A (240 VAC)1.51 A (208 VAC)Nominal frequency60 HzExtended frequency range47 - 68 HzAC short circuit fault current over 3 cycles5.8 ArmsMaximum units per 20 A (L-L) branch circuit³12 (240 VAC)10 (208 VAC)Overvoltage class AC portIIIAC port backfeed current18 mAPower factor setting1.0Power factor (adjustable)0.85 leading ... 0.85 laggingEFFICIENCY@240 VAC@208 VACCEC weighted efficiency97.5 %97.0 %MECHANICAL DATAAmbient temperature range-40ºC to +60ºCRelative humidity range4% to 100% (condensing)Connector type (IQ7X-96-2-US)MC4 (or Amphenol H4 UTX with optional Q-DCC-5 adapter)Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket)Weight1.08 kg (2.38 lbs)CoolingNatural convection - No fansApproved for wet locationsYesPollution degreePD3EnclosureClass II double-insulated, corrosion resistant polymeric enclosureEnvironmental category / UV exposure ratingNEMA Type 6 / outdoorFEATURESCommunicationPower Line Communication (PLC)MonitoringEnlighten Manager and MyEnlighten monitoring optionsCompatible with Enphase IQ EnvoyDisconnecting meansThe AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690.ComplianceCA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions.Enphase IQ 7X Microinverter X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018)The IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure. It streamlines IQ Microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly.IQ Combiner 4/4CTo learn more about Enphase offerings, visit enphase.comData SheetEnphase NetworkingSmart• Includes IQ Gateway for communication and control• Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C• Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat• Supports Wi-Fi, Ethernet, or cellular connectivity• Optional AC receptacle available for PLC bridge• Provides production metering and consumption monitoringSimple• Mounts on single stud with centered brackets• Supports bottom, back and side conduit entry• Allows up to four 2-pole branch circuits for 240VAC plug-in breakers (not included)• 80A total PV or storage branch circuitsReliable• Durable NRTL-certified NEMA type 3R enclosure• Five-year limited warranty• Two years labor reimbursement program coverage included for both the IQ Combiner SKU's• UL listed • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with IEEE 1547:2018 (UL 1741-SB, 3rd Ed.)X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018)IQ-C-4-4C-DS-0103-EN-US-12-29-2022© 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change.MODEL NUMBERIQ Combiner 4 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018)IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to deflect heat.IQ Combiner 4C X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018)IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat.ACCESSORIES AND REPLACEMENT PARTS(not included, order separately)Supported microinvertersIQ6, IQ7, and IQ8. (Do not mix IQ6/7 Microinverters with IQ8)Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan- 4G based LTE-M1 cellular modem with 5-year Sprint data plan- 4G based LTE-M1 cellular modem with 5-year AT&T data planCircuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-BSupports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit supportXA-SOLARSHIELD-ESReplacement solar shield for IQ Combiner 4/4CXA-PLUG-120-3Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01)X-IQ-NA-HD-125AHold-down kit for Eaton circuit breaker with screwsConsumption monitoring CT (CT-200-SPLIT/CT-200-CLAMP)A pair of 200A split core current transformersELECTRICAL SPECIFICATIONSRatingContinuous dutySystem voltage120/240VAC, 60 HzEaton BR series busbar rating125AMax. continuous current rating65AMax. continuous current rating (input from PV/storage)64AMax. fuse/circuit rating (output)90ABranch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included)Max. total branch circuit breaker rating (input)80A of distributed generation/95A with IQ Gateway breaker includedIQ Gateway breaker10A or 15A rating GE/Siemens/Eaton includedProduction metering CT200A solid core pre-installed and wired to IQ GatewayMECHANICAL DATADimensions (WxHxD)37.5 cm x 49.5 cm x 16.8 cm (14.75 in x 19.5 in x 6.63 in). Height is 53.5 cm (21.06 in) with mounting brackets.Weight7.5 kg (16.5 lbs)Ambient temperature range-40ºC to +46ºC (-40ºF to 115ºF)CoolingNatural convection, plus heat shieldEnclosure environmental ratingOutdoor, NRTL-certified, NEMA type 3R, polycarbonate constructionWire sizes• 20A to 50A breaker inputs: 14 to 4 AWG copper conductors• 60A breaker branch input: 4 to 1/0 AWG copper conductors• Main lug combined output: 10 to 2/0 AWG copper conductors• Neutral and ground: 14 to 1/0 copper conductors• Always follow local code requirements for conductor sizing.AltitudeUp to 3,000 meters (9,842 feet)INTERNET CONNECTION OPTIONSIntegrated Wi-FiIEEE 802.11b/g/nCellularCELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Mobile Connect cellular modem is required for all Enphase Energy System installations.EthernetOptional, IEEE 802.3, Cat5E (or Cat6) UTP Ethernet cable (not included)COMPLIANCECompliance, IQ CombinerCA Rule 21 (UL 1741-SA)IEEE 1547:2018 - UL 1741-SB, 3rd Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C)CAN/CSA C22.2 No. 107.1, Title 47 CFR, Part 15, Class B, ICES 003Production metering: ANSI C12.20 accuracy class 0.5 (PV production)Consumption metering: accuracy class 2.5Compliance, IQ GatewayUL 60601-1/CANCSA 22.2 No. 61010-1IQ Combiner 4/4CIQ-C-4-4C-DS-0103-EN-US-12-29-2022 567&(QWHUSULVHV,QF +HLPVWHDG5RDG (DX&ODLUH:, -- 2XWGRRU3KRWRYROWDLF(QFORVXUHV 6HULHV (7/OLVWHGDQGODEHOHG 5HSRUW357-5HYLVHG0D\ · 8/7\SH5(GLWLRQ(OHFWULFDOHTXLSPHQWHQFORVXUHV · &6$&1R1HPD7\SH5 · &RQIRUPVWR8/6WDQGDUG &RPSRVLWLRQ&HGDU5RRI6\VWHP %DVLF6SHFLILFDWLRQV 0DWHULDORSWLRQV · 3RZGHUFRDWHGJDXJHJDOYDQL]HGVWHHO  KRXUVVDOWVSUD\ · 6WDLQOHVVVWHHO 3URFHVV-6HDPOHVVGUDZ VWDPSHG )ODVKLQJ-´[´ +HLJKW-´ &DYLW\-&XELFLQFKHV %DVH3ODWH · )DVWHQHGWREDVHXVLQJWRJJOHIDVWHQLQJV\VWHP · URRIGHFNNQRFNRXWV · .QRFNRXWVL]HV  ´  ´DQG  ´ · ´PPVORWWHGGLQUDLO · *URXQG%ORFN 6HULHV,QFOXGHV - :LUHVL]H- - :LUHVL]H- -' :LUHVL]H- DŽĚĞůƐĂǀĂŝůĂďůĞŝŶ'ƌĞLJ͕ůĂĐŬŽƌ^ƚĂŝŶůĞƐƐ^ƚĞĞů ^ŽůĂĞĐŬϬϳϵϵ-Ϯ^ ^ŽůĂĞĐŬϬϳϵϵ-' 3DVVWKURXJKDQGFRPELQHUNLWVDUHDYDLODEOHIRUHLWKHU $&RU'&DSSOLFDWLRQV ^ŽůĂĞĐŬϬϳϵϵ-ϱ' pe.eaton.com Eaton general duty cartridgefuse safety switchDG222NRBUPC:782113144221Dimensions:Height: 14.38 INlLength: 14.8 INlWidth: 9.7 INlWeight:10 LBNotes:Maximum hp ratings apply only when dualelement fuses are used. 3-Phase hp rating shown isa grounded B phase rating, UL listed.Warranties: Eaton Selling Policy 25-000, one (1) year fromthe date of installation of the Product oreighteen (18) months from the date of shipmentof the Product, whichever occurs first.lSpecifications:Type: General duty, cartridge fusedlAmperage Rating: 60AlEnclosure: NEMA 3RlEnclosure Material: Painted galvanized steellFuse Class Provision: Class H fuseslFuse Configuration: Fusible with neutrallNumber Of Poles: Two-polelNumber Of Wires: Three-wirelProduct Category: General duty safety switchlVoltage Rating: 240VlSupporting documents:Eatons Volume 2-Commercial DistributionlEaton Specification Sheet - DG222NRBlCertifications: UL ListedlProduct compliance: No Data______________________________________________________________________© 2016 Eaton. All rights reserved. snapnrack.comUltra RailIndustry leading Wire Management SolutionsSingle Tool Installation Mounts available for all roof typesAll SnapNrack Module Clamps & Accessories are compatible with both raiil profi lesStart Installing Ultra Rail TodayUR-40UR-60The Ultimate Value in Rooftop SolarSolar Mounting Solutions© 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.comSnapNrack_Ultra Rail Sales Brochure_v.1.4SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety.Quality. Innovative. Superior. Unparalleled Wire Management• Open rail channel provides room for running wires resulting in a long-lasting quality install• Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps• System is fully bonded and listed to UL 2703 Standard© 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.comSnapNrack Ultra Rail SystemA sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install.The Entire System is a Snap to Install• New Ultra Rail Mounts include snap-in brackets for attaching rail• Compatible with all the SnapNrack Mid Clamps and End Clamps customers love• Universal End Clamps and snap-in End Caps provide a clean look to the array edgeHeavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le-specifi c rail splice and end cap• All existing mounts, module clamps, and accessories are retained for the same great install experience July 7, 2020 SnapNrack 775 Fiero Lane, Ste. 200 San Luis Obispo, CA 93401 TEL: (877) 732-2860 Attn.: SnapNrack - Engineering Department Re: SnapNrack pre-engineered PV racking systems: · RL Universal System (Report # 2019-02916A.01 and B.01) · S200 Ground Mount System (Report # 2017-00240-D.02) · UR40 Railed System (Report # 2017-03227.11) · UR60 Railed System (Report # 2018-11940.03) Subject: Engineering certification for the State of Minnesota. PZSE, Inc. - Structural Engineers has provided engineering and span tables as presented in the above referenced reports. All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications: Building Codes: 1. ASCE/SEI 7-16, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2. 2020 Minnesota Building Code, by Minnesota Department of Labor & Industry 3. 2018 International Building Code, by International Code Council, Inc. 4. 2018 International Residential Code, by International Code Council, Inc. 5. AC428 Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012, by ICC-ES 6. Aluminum Design manual 2015, by The Aluminum Association, Inc. 7. ANSI/AWC NDS-2018, National Design Specification for Wood Construction, by the American Wood Council This letter certifies that the design criteria and design methodology for the SnapNrack product span tables are in compliance with the above codes. Please refer to the system specific Engineering Certification Reports (listed above) for system specific design criteria and limitations. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. – Structural Engineers Roseville, CA S T ATEOFMINNESOTA52544ENGINEERPAULK.ZACHER PROFESSIONALLICENSEDI hereby certify that this plan, specification, or report wasprepared by me or under my direct supervision and that Iam a duly Licensed Professional Engineer under the laws ofthe state of Minnesota.Signature: _______________________________________Typed or Printed Name: ____________________________Date: _______________ License Number:______________52544EXP. 06/30/202207/07/2020Paul Zacher snapnrack.comCertification DetailsSnapNrack Ultra Rail system has been evaluated by Underwriters Laboratories (UL) and Listed to UL/ANSI Standard 2703 for Grounding/Bonding, Mechanical Loading, and Fire Classification.The Ultra Rail system has been designed in compliance with UL Standard 2703 Section 9.1 Exception, which permits accessible components that are not part of the fault current ground path to not be electrically bonded to the mounting system (e.g. roof attachments, array skirt, etc.). For more details on the integrated grounding functionality see the Grounding Specifications section.This racking system may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. See the Grounding Specifications for the list of modules tested with the Ultra Rail system for integrated grounding.Ground Lugs have been evaluated to both UL 467 and UL 2703 Listing requirements.Ultra Rail has been listed with a number of Module Level Power Electronic (MLPE) devices. A complete list can be found in the Grounding Specifications section.The mounting system Bonding Listing is only valid when installed with a Non-Separately Derived PV system. The PV system is required to have a direct electrical connection to another source, such as connecting to the grid via a grid interactive inverter.SnapNrack recommends that bare copper never come into contact with aluminum.Grounding/BondingThe Ultra Rail system is Listed for mechanical loading for dierent load ratings depending on the mounting configuration and PV module installed. For more details on the mechanical loading details see the Mechanical Loading Specifications section.SnapNrack engineered systems should only be used with SnapNrack components and hardware. Any application outside of those specified in this Installation Manual and the Structural Engineering Report may void the warranty and structural certification could become invalid.If the module clamps have been engaged and need to be loosened and reengaged, SnapNrack recommends moving the module frame 3mm to engage the bonding pin in a new location.The UL Listing covers mechanical load ratings for the various span lengths, module orientations and positive, negative, and side load ratings. These values can be found in the Mechanical Loading Specifications section.SnapNrack recommends a periodic re-inspection of the completed installation for loose components, loose fasteners, and any corrosion, such that if found, the aected components are to be immediately replaced.Mechanical LoadingFireThe Ultra Rail system has been evaluated for a Class A System Fire Classification for a Steep-Sloped Roof (≥ 2:12 pitch) using Type 1 and Type 2 modules. In order to maintain the System Classification, modules are clamped to the mounting rails between 0 and 12 inches from the top and bottom edges of the module.The Ultra Rail system has been evaluated for a Class A System Fire Classification for a Low-Sloped Roof (< 2:12 pitch) using Type 1 and Type 2 modules. In order to maintain the System Classification, modules are clamped to the mounting rails be-tween 0 and 16.3 inches from the top and bottom edges of the module.The optional Array Skirt accessory has also been evaluated and the Ultra Rail system will maintain the Class A System Fire Classification detailed above if installed with the Skirt.Because the system was tested at 5 inches above the test roof fixture Ultra Rail can be installed without any height restric-tions and will maintain the Class A System Fire Classification. See Rail Installation section for potential module-specific height restrictions due to module temperature. snapnrack.com63Ultra Rail has been tested with the following UL Listed modules:The Ultra Rail System employs top-down clamps which have been evaluated for frame-to-system bonding, at specific mounting torques and with the specific modules listed below. Ultra Rail has been tested with the following UL Listed module series: The Ultra Rail System employs top-down clamps which have been evaluated for frame-to-system bonding, at specific mounting torques and with the specific module series listed below. All wattage values are covered.ManufacturerModelAptos SolarDNA-120-MF23-XXXDNA-120-BF26-XXXWDNA-120-BF23-XXXDNA-144-BF26-XXXWDNA-144-MF23-XXXDNA-108-BF10-xxxWDNA-144-BF23-XXXDNA-120-BF10-xxxWDNA-120-MF26-XXXWDNA-108-MF10-xxxWDNA-144-MF26-XXXWBoviet SolarBVM6610P-XXXBVM6612P-XXXBVM6610M-XXXBVM6612M-XXXCanadian SolarCS6K-XXX-MCS3U-XXX-MSCS6K-XXX-M-SDCS3U-XXX-PCS6K-XXX-PCS1K-XXX-MSCS6K-XXX-P-SDCS1H-XXX-MSCS6K-XXX-MSCS1H-XXX-MS-ABCS6P-XXX-MCS3W-XXX-PCS6P-XXX-PCS3N-XXX-MSCS6P-XXX-P-SDCS1Y-XXX-MSCS6V-XXX-MCS3W-XXXMB-AGCS6V-XXX-PCS3Y-XXXMB-AGCS6X-XXX-PCS6W-XXXMB-AGCS3K-XXX-PCS6R-XXXMS-HLCS3K-XXX-MSCS3W-XXX-MSCertainTeedCTXXXHC11-06Chint SolarCHSM6612M-XXXCHSM72M-HC-XXX* (Astro 4)CHSM6612M(BL)-XXXCHSM72M-HC-XXX* (Astro 5)CHSM6612M/HV-XXXDehui SolarDH-M760B-XXXWDH-M760F-XXXW*DH-M760W-XXXWDH-M772F-XXXW*DH-M772W-XXXWET SolarET-P660XXXBBP660XXXWB/WWET-P660XXXWBP660XXXWWGET-P660XXXWWM660XXXBBET-P660XXXWWGM660XXXWWFreedom ForeverFF-MP-BBB-xxxHanwha Q CellsQ.PEAK BLK-G3.1-XXXQ.PEAK DUO-L-G7.2-XXXQ.PEAK G3.1-XXXQ.PEAK DUO-L-G7.3-XXXQ.PLUS BFR-G3.1-XXXQ.PEAK DUO-L-G6-XXXGrounding Specificationssnapnrack.com64Grounding SpecificationsManufacturerModelHanwha Q CellsB.LINE PLUS BFR-G4.1-XXXQ.PEAK DUO-L-G6.2-XXXB.LINE PRO BFR-G4.1-XXXQ.PEAK DUO-L-G6.3-XXXQ.BASE GY-XXXQ.PEAK DUO-L-G8-XXXQ.PEAK BFR-G4-XXXQ.PEAK DUO-L-G8.1-XXXQ.PEAK BFR-G4.1-XXXQ.PEAK DUO-L-G8.2-XXXQ.PEAK BLK-G4.1-XXXQ.PEAK DUO-L-G8.3-XXXQ.PEAK BLK-G4.1/TAA-XXXQ.PEAK DUO-G5/SC-XXXQ.PEAK G4-XXXQ.PEAK DUO-BLK-G5/SC-XXXQ.PEAK G4.1-XXXQ.PEAK DUO-G6+/SC-XXXQ.PEAK G4.1/MAX-XXXQ.PEAK DUO-BLK-G6+/SC-XXXQ.PEAK G4.1/TAA-XXXQ.PEAK DUO BLK-G6+/AC-XXXQ.PLUS BFR-G4-XXXQ.PEAK DUO-ML-G9-XXXQ.PLUS BFR-G4.1-XXXQ.PEAK DUO-BLK-ML-G9-XXXQ.PLUS BFR-G4.1/TAA-XXXQ.PEAK DUO-BLK-G9-XXXQ.PLUS G4-XXXQ.PEAK DUO-BLK-G9+-XXXQ.PLUS GY-XXXQ.PEAK DUO-ML-G9+-XXXQ.PLUS BFR-GY-XXXQ.PEAK DUO-BLK-ML-G9+-XXXQ.PRO BFR-G4-XXXQ.PEAK DUO-G5/TS-XXXQ.PRO BFR-G4.1-XXXQ.PEAK DUO BLK-G5/TS-XXXQ.PRO BFR-G4.3-XXXQ.PEAK DUO-G6/TS-XXXQ.PRO BFR-GY-XXXQ.PEAK DUO BLK-G6/TS-XXXQ.PRO BLK-GY-XXXQ.PEAK DUO-G6+/TS-XXXQ.PRO G4-XXXQ.PEAK DUO BLK-G6+/TS-XXXQ.PRO GY-XXXQ.PEAK DUO XL-G9.2-XXXQ.PRO GY/SC-XXXQ.PEAK DUO XL-G9.3-XXXQ.PEAK DUO-G5-XXXQ.PEAK DUO XL-G9.3/BFG-XXXQ.PEAK DUO-BLK-G5-XXXQ.PEAK DUO XL-G10.2-XXXQ.PLUS DUO-G5-XXXQ.PEAK DUO XL-G10.3/BFG-XXXQ.PEAK DUO-G7-XXXQ.PEAK DUO XL-G10.3-XXXQ.PEAK DUO-BLK-G7-XXXQ.PEAK DUO XL-G10.c-XXXQ.PEAK DUO-G7.2-XXXQ.PEAK DUO XL-G10.d-XXXQ.PEAK DUO-G6+-XXXQ.PEAK DUO L-G8.3/BFG-XXXQ.PEAK DUO-BLK-G6+-XXXQ.PEAK DUO L-G8.3/BGT-XXXQ.PEAK DUO-G6-XXXQ.PEAK DUO ML-G10-XXXQ.PEAK DUO-BLK-G6-XXXQ.PEAK DUO BLK ML-G10+-XXXQ.PEAK DUO-G8+-XXXQ.PEAK DUO ML-G10+-XXXQ.PEAK DUO-BLK-G8+-XXXQ.PEAK DUO BLK ML-G10-XXXQ.PEAK DUO-G8-XXXQ.PEAK DUO ML-G10.a+-XXXQ.PEAK DUO-BLK-G8-XXXQ.PEAK DUO BLK ML-G10.a+-XXXQ.PLUS L-G4-XXXQ.PEAK DUO ML-G10.a-XXXQ.PLUS L-G4.1-XXXQ.PEAK DUO BLK ML-G10.a-XXXQ.PLUS L-G4.2-XXXQ.PEAK DUO BLK ML-G10.a+/TS-XXXQ.PEAK L-G4.1-XXXQ.PEAK DUO G10-XXXQ.PEAK L-G4.2-XXXQ.PEAK DUO BLK G10-XXXQ.PLUS DUO-L-G5-XXXQ.PEAK DUO G10+-XXX snapnrack.com65Grounding SpecificationsManufacturerModelHanwha Q CellsQ.PLUS DUO-L-G5.1-XXXQ.PEAK DUO BLK G10+-XXXQ.PLUS DUO-L-G5.2-XXXQ.PEAK DUO BLK G10+/AC XXXQ.PLUS DUO-L-G5.3-XXXQ.PEAK DUO BLK G10+/HL XXXQ.PEAK DUO-L-G5.2-XXXQ.PEAK DUO XL-G11.3 XXXQ.PEAK DUO-L-G5.3-XXXQ.PEAK DUO XL-G11.3 BFG XXXQ.PEAK DUO-L-G7-XXXQ.TRON-G1+ XXXQ.PEAK DUO-L-G7.1-XXXQ.TRON BLK-G1+ XXXHanwha SolarOneHSL60P6-PB-2-XXXQHSL60P6-PB-4-XXXQHeliene60M-XXX72M-XXX60P-XXX72P-XXXHT-SAAEHT60-166M-XXXHT60-182M-XXXHyundaiHiS-MXXXRGHiA-SXXXMSHiS-SXXXRGHiS-SXXXXYHiS-SXXXRWHiS-SXXXYIHiS-MXXXMGHiS-SxxxYH(BK)HiS-SXXXMGAll may be followed by (BK)HiD-SXXXRGHyperion/RunergyHY-DH108P8-XXX(Y)JA SolarJAM6-60-XXX/SIJAM72S10-XXX/MRJAP6-60-XXX/3BBJAM72S10-XXX/PRJAM60S09-XXX/PRJAM72S12-XXX/PRJAM60S10-XXX/MRJAP6(k)-72-XXX/4BBJAM60S10-XXX/PRJAM60S17-XXX/MRJAM60S12-XXX/PRJAM54S30-XXX/MRJAP72S01-XXX/SCJAM54S31-XXX/MRJAM72S09-XXX/PRJAM72D30-XXX/MBJinko SolarJKMXXXM-60JKMXXXP-72-VJKMXXXM-60LJKMXXXPP-72JKMXXXM-60HLJKMXXXPP-72-VJKMXXXM-60HBLJKMSXXXP-72JKMXXXP-60JKMXXXM-72HL-VJKMXXXP-60-J4JKMXXXM-72HL-TVJKMXXXP-60-VJKMXXXM-72HBLJKMXXXP-60B-J4JKMXXXM-6TL3-BJKMXXXPP-60JKMXXXM-6RL3-BJKMXXXPP-60-VJKMXXXM-7RL3-VJKMXXXM-72JKMXXXM-7RL3-TVJKMXXXM-72L-VJKMXXXM-72HL4-VJKMXXXP-72JKMXXXM-72HL4-TVKyoceraKUXXX-6YYYKUXXX-8YYYLGLGXXXN1C-A5LGXXXA1C-V5LGXXXN1K-A5LGXXXM1C-L5LGXXXQ1C-A5LGXXXM1K-L5LGXXXQ1K-A5LGXXXN1C-N5snapnrack.com66Grounding SpecificationsManufacturerModelLGLGXXXS1C-A5LGXXXN1K-L5LGXXXN2C-B3LGXXXN1K-A6LGXXXN2W-B3LGXXXN1C-A6LGXXXN1C-G4LGXXXN1W-A6LGXXXN1K-G4LGXXXQ1C-A6LGXXXS1C-G4LGXXXQ1K-A6LGXXXN2C-G4LGXXXM1K-A6LGXXXN2K-G4LGXXXM1C-A6LGXXXN2W-G4LGXXXA1C-A6LGXXXS2C-G4LGXXXQAC-A6LGXXXS2W-G4LGXXXQAK-A6LGXXXN1C-V5LGXXXN1K-B6LGXXXN1W-V5LGXXXN2W-E6LGXXXN2T-V5LGXXXN2T-E6LGXXXN2T-J5LGXXXN1K-E6LGXXXN1T-V5LGXXXN3K-V6LongiLR6-60-XXXMLR4-60HPB-XXXMLR6-60BK-XXXMLR4-60HIB-XXXMLR6-60HV-XXXMLR4-60HPH-XXXMLR6-60PB-XXXMLR4-60HIH-XXXMLR6-60PE-XXXMLR6-60HIH-XXXMLR6-60PH-XXXMLR6-60HIB-XXXMLR6-60HPB-XXXMLR4-72HPH-XXXMLR6-60HPH-XXXMMeyer BurgerMeyer Burger Black*Meyer Burger White*mSolarTX16-XXX120BBMission SolarMSEXXXSO5TMSEXXXSR8KMSEXXXSO5KMSEXXXSR8TMSEXXXSQ5TMSEXXXSR9SMSEXXXSQ5KMSE60AXXXMSEXXXMM4JMSEXXXTS60MSEXXXMM6JMSEXXXSX5KMSEXXXSO6WMSEXXXSX5TMSEXXXSO4JMSEXXXSX6SMSEXXXSO6JMSEXXXSX6WMSEXXXSQ6SMSExxxSX5RMSEXXXSQ4SNext Energy AllianceUSNEA-XXXM3-60USNEA-XXXM3-72USNEA-XXXM3B-60USNEA-XXXM3B-72PanasonicVBHNXXXKA01VBHN325SA17EVBHNXXXKA02VBHXXXRA18NVBHNXXXSA16VBHXXXRA03KVBHNXXXKA03EVPVXXX(K) snapnrack.com67Grounding SpecificationsManufacturerModelPanasonicVBHNXXXKA04EVPVXXXHVBHNXXXSA17EVPVXXXPKVBHNXXXSA18Phono SolarPSXXXM-20/UPSxxxM8GF-18/VHPSXXXMH-20/UPSxxxM8GFH-18/VHPSxxxM8GF-24/THPSxxxM6-24/THPSxxxM8GFH-24/THRECRECXXXPERECXXXTP2M 72 BLK2RECXXXPE-BLKRECXXXTP2SM 72RECXXXTPRECXXXTP2SM 72 BLKRECXXXTP-BLKRECXXXTP2SM 72 BLK2RECXXXTP IQRECXXXAARECXXXTP2RECXXXTP3RECXXXTP2-BLKRECXXXTP3MRECXXXNPRECXXXTP4RECXXXTP2MRECXXXAA PureRECXXXTP72RECxxxAA Pure-RRECXXXPE72RECXXXNP2RECXXXPE72XVRECxxxNP3RECXXXTP2M 72All may be followed by BLK or BLACKRECXXXTP2M 72 BLKRenesolaJCXXXM-24/BbJCXXXM-24/BBhSEG SolarSEG-400-BMB-HVSEG-xxx-BMD-HVSEG-400-BMB-TBSEG-xxx-BMD-TBSilfabSLAXXX-MSILXXXNTSLAXXX-PSILXXXHLSSAXXX-MSILXXXBKSSAXXX-PSILXXXHCSILXXXBLSILXXXNUSILXXXMLSILXXXNXSILXXXNLSILXXXHNSLGXXX-MSILXXXBGSLGXXX-PSIL-xxxHC+SSGXXX-MSIL-xxxHMSSGXXX-Psnapnrack.com68ManufacturerModelSolariaSolaria PowerXT-XXXR-PXSolaria PowerXT-XXXR-PMSolaria PowerXT-XXXR-BXSolaria PowerXT-XXXR-PM-ACSolaria PowerXT-XXXR-ACSolarWorldSWXXX-MonoSWXXX-Mono XLSunivaMVX-XXX-60-5-701OPT-XXX-60-4-1B0MVX-XXX-60-5-7B1OPT-XXX-60-4-800OPT-XXX-60-4-100OPT-XXX-60-4-8B0SunpowerSPR-EYY-XXXSPR-AXXXSPR-XYY-XXXSPR-AXXX-BLK-G-ACSPR-EYY-XXXSPR-AXXX-BLKSPR-XYY-XXXSPR-MXXX-H-ACSPR-P17-XXX-COMSPR-MXXXSPR-P19-XXX-COMSPR-MXXX-BLK-H-ACSPR-AXXX-G-ACSPR-MXXX-BLKSunSparkSST-XXXM3-60SST-XXXM3-72SST-XXXM3B-60SST-XXXM3B-72TalesunTP660M-XXXTP672M-XXXTP660P-XXXTP672P-XXXTeslaTXXXSTXXXHTrinaTSM-XXXDD05(II)TSM-XXXDD06M.05(II)TSM-XXXDD05A.05(II)TSM-XXXDE15H(II)TSM-XXXDD05A.08(II)TSM-XXXDE15M(II)TSM-XXXDD05A.082(II)TSMXXXDD05H.05(II)TSM-XXXPA05TSMXXXDE06X.05(II)TSM-XXXPA05.05TSMXXXDE09.05TSM-XXXPA05.08TSMXXXDE15V(II)TSM-XXXPD05TSMXXXDEG15VC.20(II)TSM-XXXPD05.002TSMXXXDEG18MC.20(II)TSM-XXXPD05.05TSM-XXXDE19TSM-XXXPD05.05STSMXXXDEG19C.20TSM-XXXPD05.08TSMXXXDEG21C.20TSM-XXXPD05.082TSMXXXDE09C.05TSM-XXXPD05.08DTSMXXXDE09C.07TSM-XXXPD05.08STSM-xxxNE09RC.05Grounding Specifications snapnrack.com69Grounding SpecificationsManufacturerModelVikram SolarSOMERA VSMHBB.60.XXX.05PREXOS VSMDHT.60.XXX.05SOMERA VSMH.72.XXX.05PREXOS VSMDHT.72.XXX.05VSUNVSUNXXX-144BMH-DGVSUNXXX-108BMHVSUNXXX-120BMHYingliYLXXXA-29bYLXXXP-29bZNShineZXM6-60-XXX/MZXM6-NH144-XXXMZXM6-NH120-XXXMZXM7-SH108-XXXM snapnrack.comSpeedSealTM DeckFootEliminates locating rafters & pilot holes Features SpeedSealTMTechnology Ability to mount on specialty roof typesPre-assembled with L Foot & Ultra Rail MountStart Installing the DeckFoot Today Ultra RailDirect to Deck Attachment for Ultra Rail© 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.comSnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety.Quality. Innovative. Superior. Eliminate Disruption on the Roof• Maintain the roof integrity, no prying up shingles• Each screw independently sealed• Sealant venting ports indicate proper seal © 2021 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.comThe SpeedSealTM DeckFootis part of a new generation of roof attachments for Ultra Rail, featuring an innovative design that incorporates SpeedSealTM Technology into a single roof attachment that mounts directly to the deck. Rafter Independent Attachment• Eliminates the need to locate or find rafters for pilot holes• Single attachment secured straight to the roofUltimate Rooftop Versatility • Allows for layout adjustability on the roof without the need to locate & attach to rafters• Familiar SpeedSealTM Technology with compressible barrier that secures sealant in place & fills voids • Ability to mount on specialty roof structures without standard rafters including TJI’s, metal rafters, tongue & groove, and manufactured homes