HomeMy WebLinkAboutLA218130 - 5364 177th St W Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
_____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
NAME OF APPLICANT (Please Print)DATE
I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS
APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO
COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH
LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED
PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE
CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE
ESCROW APPLICATION AND REFUND.
OFFICE PHONE #:_
OFFICE PHONE #:_
*Entering your name affirms your intent to comply with the statement above.
*
Submit Application To: permits@lakevillemn.gov
paul@pinnaclefamilyhomes.com
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT
CONDO
REROOF
RESIDE
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES
LOWER LEVEL FINISH
ADDITION
FOUNDATION ONLY
MISCELLANEOUS
DEMO
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
CITY BUILDING VALUATION: $
BUILDING PERMIT FEES
$PERMIT FEE
$PLAN CHECK
$SURCHARGE
$METRO SAC
$CITY WATER HOOKUP UNIT
$CITY SEWER HOOKUP UNIT
$LANDSCAPE ESCROW
$TREE ESCROW
$MISC ESCROW
$PLUMBING
$MECHANICAL
$SEWER WATER
WATER METER
PRESSURE REDUCING VALVE
$OTHER
$TOTAL
METER SIZE
PRESSURE REDUCING VALVE
SEWER/WATER
SEWER/WATER
FINAL
STREET DRAINTILE
BUILDING INFORMATION
TYPE OF CONSTRUCTION
ZONING
CODE EDITION
FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
MECHANICAL
AIR TEST
FINAL
ROUGH-IN
PLUMBING
FINAL
ROUGH-IN
INSULATION
LATH
DECK FOOTING
FIREPLACE
FOOTING
FOUNDATION
FRAMING
PORCH FRAMING
PORCH FOOTING
POURED WALL
SITE
LOWER LEVEL FINAL
OTHER
DECK FRAMING
LOWER LEVEL FRAMING
LANDSCAPING
DECK FINAL
$
$
ACCESSORY BUILDING
EGRESS WINDOW
UNDERGROUND
12
10
12
8
12
10
12
7
Main Level Floor
2' - 2 1/4"
Basement Level Clg
0' - 7 1/2"Garage Floor
0' - 0"
Upper Level Floor
12' - 4"
Upper Level Floor
12' - 4"Main Level Clg
11' - 3 3/8"APPROX. 9'-1 1/8"Upper Level Clg
20' - 5 1/8"
Upper Level Clg
20' - 5 1/8"APPROX. 8'-1 1/8"APPROX. 10'-3 3/8"APPROX. 8'-1 1/8"7" / 12"7" / 12"16'-0"8'-0"
1'-4"1'-0"
ASPHALT
SHINGLES
ASPHALT
SHINGLES
VINYL
LAP SIDING
VINYL VERTICAL
SIDING
VINYL
LAP SIDING
VINYL
LAP SIDING
VINYL VERTICAL
SIDING
6"
F
R
I
E
Z
E
B
O
A
R
D
Garage Clg
10' - 3 3/8"
1'-4"6" FRIEZE BOARD6"
F
R
I
E
Z
E
B
O
A
R
D
4'-0"6" FRIEZE BOARD
14" MIRATEC COLUMNPANEL DOOR
ASPHALT
SHINGLES
METAL ROOFING
VINYL
LAP SIDING
8'-0"Main Level Floor
2' - 2 1/4"
Basement Level Flr
-7' - 2 1/2"
Basement Level Clg
0' - 7 1/2"Garage Floor
0' - 0"
Upper Level Floor
12' - 4"Main Level Clg
11' - 3 3/8"
Upper Level Clg
20' - 5 1/8"APPROX. 8'-1 1/8"APPROX. 9'-1 1/8"APPROX. 7'-10"8" / 12"APPROX. 10'-3 3/8"1'-4"
VINYL
LAP SIDING
VINYL
LAP SIDING
VINYL
LAP SIDING
VINYL
LAP SIDING
ASPHALT
SHINGLES
ASPHALT
SHINGLES
1'-0"
Garage Clg
10' - 3 3/8"
1'-0"4'-0"10" / 12"10" / 12"8'-0" WDW HEAD HT (TYP)1'-2"2'-6"2"6"4x4 CEDAR POST
6x6 TREATED POST
- BOXED w/DBL. 2x4 TRT. NAILERS AT 20.5" O/C
- L.P. PANEL BOARD OVER 2x4 NAILERS
- 5/4x6 MIRATEC TRIM AT TOP OVER PLYWOOD
- 5/4x10 MIRATEC TRIM AT BOTTOM OVER PLYWOOD
- 5/4x3 MIRATEC TRIM BETWEEN & TOP TRIM
5/4x10 MIRATEC
4/4x2 & 4/4x3 MIRATEC CORNER
6x6 TREATED POST
DBL. 2x4 TRT. NAILERS AT 20.5" O/C
5/4x6 MIRATEC
FINISHED
15 1/4 "
14 1/4
1/4" = 1'-0"A1
1FRONT ELEVATION OFFICE: (952) 746-7702 | FAX: (952) 746-7703CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE:DRAWN BY: c 2023 BEHR DESIGN, INC.THIS DRAWING AND DESIGN LAYOUT IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN CONSENT FROM BEHR DESIGN, INC.PROJECT FILE: BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.A1
Ext ElevationsPinnacle Family HomesCharleston Model5364 177th St.Lakeville, MNPeter K.9/19/202323-PFH 1/4" = 1'-0"A1
2RIGHT SIDE ELEVATION
1/2" = 1'-0"A1
4 BRACKET DETAIL
1/2" = 1'-0"A1
5 COLUMN DETAIL
A1
3 FRONT 3D VIEW
Concept Approval
ONLY
Subject to Field Inspection
Inspector Date
2020
MN Bldg
Code
09/19/2023dmathews
12
7
Main Level Floor
2' - 2 1/4"
Basement Level Flr
-7' - 2 1/2"
Basement Level Clg
0' - 7 1/2"Garage Floor
0' - 0"
Upper Level Floor
12' - 4"Main Level Clg
11' - 3 3/8"
Upper Level Clg
20' - 5 1/8"APPROX. 7'-10"APPROX. 9'-1 1/8"APPROX. 8'-1 1/8"7" / 12"7" / 12"1'-0"
1'-4"
1'-0"
ASPHALT
SHINGLES
ASPHALT
SHINGLES
VINYL
LAP SIDING
VINYL
LAP SIDING
VINYL
LAP SIDING
Garage Clg
10' - 3 3/8"8'-0" WDW HEAD HT (TYP)6'-8" WDW HEAD HT (TYP)APPROX. 10'-3 3/8"Main Level Floor
2' - 2 1/4"
Basement Level Flr
-7' - 2 1/2"
Basement Level Clg
0' - 7 1/2"Garage Floor
0' - 0"
Upper Level Floor
12' - 4"Main Level Clg
11' - 3 3/8"
Upper Level Clg
20' - 5 1/8"APPROX. 8'-1 1/8"APPROX. 9'-1 1/8"APPROX. 7'-10"10'-3 3/8"1'-0"
1'-4"8" / 12"ASPHALT
SHINGLES
VINYL
LAP SIDING
VINYL
LAP SIDING
VINYL
LAP SIDING10" / 12"Garage Clg
10' - 3 3/8"8'-0" WDW HEAD HT (TYP)6'-8" WDW HEAD HT (TYP)OFFICE: (952) 746-7702 | FAX: (952) 746-7703CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE:DRAWN BY: c 2023 BEHR DESIGN, INC.THIS DRAWING AND DESIGN LAYOUT IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN CONSENT FROM BEHR DESIGN, INC.PROJECT FILE: BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.A2
Ext ElevationsPinnacle Family HomesCharleston Model5364 177th St.Lakeville, MNPeter K.9/19/202323-PFH 1/4" = 1'-0"A2
1REAR ELEVATION
1/4" = 1'-0"A2
3LEFT SIDE ELEVATION
A2
2 REAR 3D VIEW
Secure door closed until deck is
constructed with a separate permit.
FD
WH
16'-0"5'-10"28'-2"50'-0"20'-0"30'-0"21'-10"28'-2"50'-0"17'-0"11'-2"2
A6
UP
4'-6"12'-6"3'-9"6'-0"4'-2"4'-2"4'-0"8'-7"
50'-0"
11'-10"14'-0"14'-0"7'-10"
60" FIBERGLASS
SHOWER
REC ROOM
BEDROOM
MECH
5040
5'-0"x4'-0"
5040
5'-0"x4'-0" 8'-0"x6'-8" GLIDING DOOR
UNEXCAVATED
UNEXC.13'-0"4'-0"11'-2"4'-0"x1'-10" VANITY 2468266826682868266826681'-10 1/2"16'-3"1'-9"8'-3"1'-10 1/2"
FURN.
SUMP
47'-8"2'-2"
49'-10"
FUTURE
FUTURE
5
A6
BATHFUTURE
DROPPED HEADER OFFICE: (952) 746-7702 | FAX: (952) 746-7703CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE:DRAWN BY: c 2023 BEHR DESIGN, INC.THIS DRAWING AND DESIGN LAYOUT IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN CONSENT FROM BEHR DESIGN, INC.PROJECT FILE: BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.A3
Basement PlanPinnacle Family HomesCharleston Model5364 177th St.Lakeville, MNPeter K.9/19/202323-PFH 1/4" = 1'-0"A3
1BASEMENT PLAN
NOTES:
1.) ALL BRG. HEADERS ARE TO BE (2)-2x10 UNLESS NOTED OTHERWISE (UNO).
2.) OWNER/CONTRACTOR TO VERIFY ALL WINDOW & DOOR SIZES.
3.) OWNER/CONTRACTOR TO SPEC. ALL FLOORING MATERIAL.
4.) OWNER/CONTRACTOR TO VERIFY ALL DIMENSIONS.
5.) ALL BRG WALL WINDOW & DOOR OPNG'S WIDER THAN 60" REQUIRE (2) TRIMMERS MIN.
UNDER EA. SIDE OF HEADER.
6.) (FL) - FLUSH BEAM, (DR) DROPPED BEAM
7.) ALL HEADERS ARE DROPPED UNLESS NOTED (FL)
8.) USE ENERGY HEEL HEIGHT ON ROOF TRUSSES.
-
48'-0"2'-0"22'-0"28'-0"16'-0"6'-0"28'-0"50'-0"20'-0"30'-0"
50'-0"
50'-0"50'-0"5'-7"5'-5"17'-0"6'-11"8'-4"5'-6"7'-3"2'-0"
2
A6
16'-0"x8'-0" OVERHEAD DOOR 8'-0"x8'-0" OVERHEAD DOOR
2'-0"16'-0"2'-0"8'-0"2'-0"
DNUP
FOYER
GREAT ROOM
DININGKITCHEN
MUD
PANTRY POWDEROFFICE
11'-0"16'-0"13'-0"8'-0"
DW
30" RANGEw/HOOD ABOVEREFG
5'-6"6'-6"6'-0"2'-0"3'-6"6'-6"3'-0"4'-6"11'-0"17'-0"3060-SH
3'-0"x6'-0"
6046 FIXED
6'-0"x4'-6" 6'-0"x8'-0" GLIDING DOOR
2640-CSMT
2'-6"x4'-0"
3'-0"x1'-10"
VANITY
2480
30685080 OPG
6020 FIXED6'-0"x2''-0" 24802480
28685'-4"5'-8"GAS FIREPLACE
COVERED
PORCH
GARAGE
2'-0"8'-2"7'-8"1'-10"9'-3"8'-4"5'-6"7'-3"11'-0"17'-0"268012"x12" SOFFITDROPPED HEADER
2'-8"5'-6"7'-8"11'-1"
FLOOR LINE ABOVE
8'-0"8'-0"4'-0"BENCH w/CUBBIES UNDER24" UPPER TO EXTEND
DOWN TO COUNTERTOP
18"
LINEN
1'-8"3'-9"2'-10"11'-1"3'-1"4080 OPG
5
A6
3060-SH
3'-0"x6'-0"
4060
4'-0"x6'-0"
3040-CSMT
3'-0"x4'-0"2040-SH2'-0"x4'-0"3050-FIXED3'-0"x5'-0"3050-FIXED3'-0"x5'-0"SHIPLAP FIRPLACE
FULL FRONT AND SIDES OFFICE: (952) 746-7702 | FAX: (952) 746-7703CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE:DRAWN BY: c 2023 BEHR DESIGN, INC.THIS DRAWING AND DESIGN LAYOUT IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN CONSENT FROM BEHR DESIGN, INC.PROJECT FILE: BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.A4
Main Floor PlanPinnacle Family HomesCharleston Model5364 177th St.Lakeville, MNPeter K.9/19/202323-PFH 1/4" = 1'-0"A4
1 MAIN FLOOR PLAN
NOTES:
1.) ALL BRG. HEADERS ARE TO BE (2)-2x10 UNLESS NOTED OTHERWISE (UNO).
2.) OWNER/CONTRACTOR TO VERIFY ALL WINDOW & DOOR SIZES.
3.) OWNER/CONTRACTOR TO SPEC. ALL FLOORING MATERIAL.
4.) OWNER/CONTRACTOR TO VERIFY ALL DIMENSIONS.
5.) ALL BRG WALL WINDOW & DOOR OPNG'S WIDER THAN 60" REQUIRE (2) TRIMMERS MIN.
UNDER EA. SIDE OF HEADER.
6.) (FL) - FLUSH BEAM, (DR) DROPPED BEAM
7.) ALL HEADERS ARE DROPPED UNLESS NOTED (FL)
8.) USE ENERGY HEEL HEIGHT ON ROOF TRUSSES.
BASEMENT LEVEL SQUARE FEET = 0 sq ft
MAIN LEVEL SQUARE FEET = 1344 sq ft
UPPER LEVEL SQUARE FEET = 1372 sq ft
TOTAL SQUARE FEET = 2716 sq ft
GARAGE SQUARE FEET = 660 sq ft
2
A6 30'-0"DN
48'-0"
10'-8"5'-0"10'-10"7'-0"14'-6"13'-2"4'-10"12'-0"2'-0"28'-0"30'-0"11'-2"16'-10"48" FIBERGLASS SHOWER PANw/TILE WALLS14'-0"34'-0"
48'-0"
13'-0"8'-4"6'-0"6'-8"
5'-0"2'-0"3'-8"
6'-2"6'-10"7'-0"6'-6"14'-6"6'-2"5'-10"5'-0"x1'-10" VANITY 60"x30"TUB/SHOWER7'-0"x1'-10" VANITY 6040
6'-0"x4'-0"
BEDROOM #2BEDROOM #3
PRIMARY SUITE
BATH LAUNDRY
BEDROOM #4
PRIMARY
BATH60" SOAKING TUB TILE SURROUNDHALF WALL
w/GLASS
7'-0"7'-0"
5'-6"5'-2"5'-5"5'-5"7'-1"7'-5"4026 FIXED4'-0"x2'-6" 246826682468
26682668
26682868246824682468
2668 OPG
24682868
8'-1"3'-1"24684'-0"9'-0"
RAILING
TYP.
2'-0"
12" BOX VAULT
2640-CSMT
2'-6"x4'-0"
5
A6
WASHER
DRYER
5040
5'-0"x4'-0"
5040
5'-0"x4'-0"
CHAIR RAIL IN HALL HALL
BARN D00R
PRIMARY
CLOSET
8040 (XOX) 1:2:1
8'-0"x4'-0"OFFICE: (952) 746-7702 | FAX: (952) 746-7703CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE:DRAWN BY: c 2023 BEHR DESIGN, INC.THIS DRAWING AND DESIGN LAYOUT IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN CONSENT FROM BEHR DESIGN, INC.PROJECT FILE: BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.A5
Upper Floor PlanPinnacle Family HomesCharleston Model5364 177th St.Lakeville, MNPeter K.9/19/202323-PFH 1/4" = 1'-0"A5
1UPPER FLOOR PLAN
NOTES:
1.) ALL BRG. HEADERS ARE TO BE (2)-2x10 UNLESS NOTED OTHERWISE (UNO).
2.) OWNER/CONTRACTOR TO VERIFY ALL WINDOW & DOOR SIZES.
3.) OWNER/CONTRACTOR TO SPEC. ALL FLOORING MATERIAL.
4.) OWNER/CONTRACTOR TO VERIFY ALL DIMENSIONS.
5.) ALL BRG WALL WINDOW & DOOR OPNG'S WIDER THAN 60" REQUIRE (2) TRIMMERS MIN.
UNDER EA. SIDE OF HEADER.
6.) (FL) - FLUSH BEAM, (DR) DROPPED BEAM
7.) ALL HEADERS ARE DROPPED UNLESS NOTED (FL)
8.) USE ENERGY HEEL HEIGHT ON ROOF TRUSSES.
12
7
Main Level Floor
2' - 2 1/4"
Basement Level Flr
-7' - 2 1/2"
Basement Level Clg
0' - 7 1/2"Garage Floor
0' - 0"
Upper Level Floor
12' - 4"Main Level Clg
11' - 3 3/8"
Upper Level Clg
20' - 5 1/8"APPROX. 7'-10"APPROX. 9'-1 1/8"APPROX. 8'-1 1/8"Garage Clg
10' - 3 3/8"APPROX. 10'-3 3/8"HEEL HT.1'-0"FRAME GARAGE WALLS
1'-0" LOWER THE MAIN WALLS1'-0"FROST FTG3'-6" MIN.ASPHALT SHINGLES
15# FELT
15/32" OSB ROOF SHEATHING
PRE-ENGINEERED/PREMANUF.
ROOF TRUSSES @ 24" O.C.
(R49) BLOWN-IN INSULATION
31/2" POURED CONC OVER
6 MIL POLY VAPOR BARRIER w/ 12" LAP OVER
4" CLEAN GRANULAR FILL
CLOSED CELL
SPRAY FOAM (R21 MIN)
3/4" PLYWOOD SUBFLOOR
18"d FLOOR TRUSSES @ 19.2" O.C.
EXTERIOR WATERPROOFING
TO FINISH GRADE
1/2" GYPSUM BOARD
HOUSE WRAP
7/16" OSB EXT WALL SHEATHING
2x6 STUDS @ 16" O.C.
(R21) BATT INSULATION
4 MIL POLY VAPOR BARRIER
1/2" GYPSUM BOARD (AIR BARRIER)
SEE PLAN FOR FTG SIZE
4" DRAIN TILE
CONT RIDGE VENT
8" POURED CONC. FDN WALL
w/ 2" (R10) RIGID INSULATION ON EXTERIOR
ICE & WATER BARRIER TO 24"
FROM INSIDE FACE OF EXT WALL
AIR BAFFLES FULL WIDTH
OF TRUSS SPACING
EXTERIOR SIDING, SEE ELEV
HOUSE WRAP
7/16" OSB EXT WALL SHEATHING
2x6 STUDS @ 16" O.C.
(R21) BATT INSULATION
4 MIL POLY VAPOR BARRIER
1/2" GYPSUM BOARD (AIR BARRIER)
1/2" GYPSUM BOARD
CLOSED CELL
SPRAY FOAM (R21 MIN)
1/2" GYPSUM BOARD
FLUSH BEAM SEE
PLAN FOR SIZE
EXTERIOR SIDING, SEE ELEV
HOUSE WRAP
7/16" OSB EXT WALL SHEATHING
2x6 STUDS @ 16" O.C.
(R21) BATT INSULATION
4 MIL POLY VAPOR BARRIER
1/2" GYPSUM BOARD (AIR BARRIER)
3/4" PLYWOOD SUBFLOOR
117/8" TJI JOISTS @ 16" O.C.APPROX. 5'-0 7/8"APPROX. 5'-0 7/8"APPROX. 5'-0 3/8"APPROX. 4'-4 3/8"ROOF TRUSS
SIDING (SEE ELEV.)
7/16" OSB EXTERIOR WALL SHEATHING
2x6 STUD WALL
1/2" GYPSUM BOARD WALL SHEATHING
1/2" GYPSUM BOARD
15/32" OSB ROOF SHEATHING
2x6 SUB-FASCIA BOARD
ASPHALT ROOF SYSTEM
ALUM. VENTED SOFFIT
R49 BLOWN-IN INSULATION
ALUM. FASCIA
SEE PLAN
SEE PLAN
ASPHALT ROOF SYSTEM
15/32" OSB ROOF SHEATHING
2x6 OUTRIGGERS
GABLE END ROOF TRUSS
ALUM. FASCIA
ALUM. SOFFIT
7/16" OSB EXTERIOR WALL SHEATHING
2x6 SUB-FASCIA
BOARD
8" FRIEZE BD
SIDING (SEE ELEV.)
DRIP EDGE
RADON VENT PIPE MIN. 12"
ABOVE ROOF SURFACE (AF103.6.1)
PROVIDE SPACE FOR FUTURE FAN INSTALLATION
-MIN. 24" DIA. CENTERED ON THE AXIS OF THE VENT STACK
-MIN. VERTICAL DISTANCE OF 3 FEET (AF103.8)
INSTALL OUTLET FOR FUTURE FAN
IN ATTIC (AF103.12)
3" MIN. DIA. PVC PIPE (AF103.6.1)RADON PIPE SHALL BE IDENTIFIED w/ LABEL ON EACH
FLOOR & ACCESSIBLE ATTICS.
LABEL TO READ "RADON REDUCTION SYSTEM".
(AF103.9)
PROVIDE A 4" MIN. THICK LAYER OF CLEAN
AGGREGATE UNDER ENTIRE BASEMENT SLAB
THE AGGREGATE TO BE 1/4" TO 2" IN SIZE. (AF103.2.1)
INSTALL A MINIMUM 6 MIL POLY UNDER SLAB.
MINIMUM 12" LAP OF ALL SEAMS. (AF103.3)
SEAL ALL JOINTS, CRACKS, OR OTHER OPENINGS
w/ POLYURETHANE CAULK OR ELASTOMERIC SEALANT
PER MANUFACTURER. (AF103.4 TO AF103.4.5)
INSTALL VENT PIPE INTO SEALED SUMP BASKET
DRAIN TILE LOOP. (AF103.6.1)
Main Level Floor
2' - 2 1/4"
Basement Level Flr
-7' - 2 1/2"
Basement Level Clg
0' - 7 1/2"
Upper Level Floor
12' - 4"Main Level Clg
11' - 3 3/8"
Upper Level Clg
20' - 5 1/8"APPROX. 7'-10"APPROX. 9'-1 1/8"APPROX. 8'-1 1/8"ASPHALT SHINGLES
15# FELT
15/32" OSB ROOF SHEATHING
PRE-ENGINEERED/PREMANUF.
ROOF TRUSSES @ 24" O.C.
(R49) BLOWN-IN INSULATION
1/2" GYPSUM BOARD
31/2" POURED CONC OVER
6 MIL POLY VAPOR BARRIER w/ 12" LAP OVER
4" CLEAN GRANULAR FILL
CLOSED CELL
SPRAY FOAM (R21 MIN)
3/4" PLYWOOD SUBFLOOR
18"d FLOOR TRUSSES @ 19.2" O.C.
EXTERIOR WATERPROOFING
TO FINISH GRADE
EXTERIOR SIDING, SEE ELEVHOUSE WRAP
7/16" OSB EXT WALL SHEATHING
2x6 STUDS @ 16" O.C.
(R21) BATT INSULATION4 MIL POLY VAPOR BARRIER
1/2" GYPSUM BOARD (AIR BARRIER)
SEE PLAN FOR FTG SIZE
4" DRAIN TILE
CONT RIDGE VENT
8" POURED CONC. FDN WALL
w/ 2" (R10) RIGID INSULATION ON EXTERIOR
ICE & WATER BARRIER TO 24"
FROM INSIDE FACE OF EXT WALL
AIR BAFFLES FULL WIDTH
OF TRUSS SPACING
EXTERIOR SIDING, SEE ELEV
HOUSE WRAP
7/16" OSB EXT WALL SHEATHING2x6 STUDS @ 16" O.C.
(R21) BATT INSULATION
4 MIL POLY VAPOR BARRIER
1/2" GYPSUM BOARD (AIR BARRIER)FROST FTG3'-6" MIN.1/2" GYPSUM BOARD
CLOSED CELL
SPRAY FOAM (R38 MIN)
CLOSED CELL
SPRAY FOAM (R21 MIN)
1/2" GYPSUM BOARD
DROPPED BEAM
SEE PLAN FOR SIZE
EXTERIOR SIDING, SEE ELEV
HOUSE WRAP
7/16" OSB EXT WALL SHEATHING
2x6 STUDS @ 16" O.C.
(R21) BATT INSULATION
4 MIL POLY VAPOR BARRIER
1/2" GYPSUM BOARD (AIR BARRIER)
3/4" PLYWOOD SUBFLOOR
117/8" TJI JOISTS @ 16" O.C.
31/2" POURED CONC OVER
4" CLEAN GRANULAR FILL
BEARING COLUMN BEYOND
FROST FTG3'-6" MIN.DROPPED BEAM
SEE PLAN FOR SIZE OFFICE: (952) 746-7702 | FAX: (952) 746-7703CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE:DRAWN BY: c 2023 BEHR DESIGN, INC.THIS DRAWING AND DESIGN LAYOUT IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN CONSENT FROM BEHR DESIGN, INC.PROJECT FILE: BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.A6
Building SectionsPinnacle Family HomesCharleston Model5364 177th St.Lakeville, MNPeter K.9/19/202323-PFH 1/4" = 1'-0"A6
2 Section @ Stairs
3/4" = 1'-0"A6
3ROOF EAVE SOFFIT & FASCIA DETAIL
3/4" = 1'-0"A6
4ROOF RAKE SOFFIT & FASCIA DETAIL
1/4" = 1'-0"A6
1Sub-Slab Depressurization
1/4" = 1'-0"A6
5 Section @ House
2
A6
16'-0"5'-10"11'-2"17'-0"50'-0"20'-0"30'-0"21'-10"28'-2"50'-0"47'-8"2'-2"17'-0"11'-2"5'-10"16'-0"4'-6"12'-6"9'-9"4'-2"4'-2"12'-7"
50'-0"
49'-10"17'-0"11'-2"1'-10 1/2"16'-3"1'-9"8'-3"1'-10 1/2"
8" POURED CONC FDN WALL
w/ 2" RIGID INSULATION ON EXTERIOR
2" LEDGE FOR CONCRETE SLAB
20"x8"d FTG.
4"x6" CURB
20"x8"d FTG.
8" POURED CONC FDN WALL
w/ 2" RIGID INSULATION ON EXTERIOR
20"x8"d FTG.
8" POURED CONC FDN WALL
w/ 2" RIGID INSULATION ON EXTERIOR
20"x8"d FTG. @ WALKOUT WALLS
8" POURED CONC. FDN WALL
2" LEDGE FOR CONCRETE SLAB
20"x8"d FTG.
8" POURED CONC FDN WALL
w/ 2" RIGID INSULATION ON EXTERIOR
20"x8"d FTG.
8" POURED CONC. FDN WALL
20"x8"d FTG.
4"x6" CURB
20"x8"d FTG.
4"x6" CURB
20"x8"d FTG.
8" POURED CONC. FDN WALL
2" LEDGE FOR CONCRETE SLAB
20"x8"d FTG.
MIN (2) 3500 LB STRAP-TYPE HOLD-DOWNS
(EMBEDDED INTO CONCRETE AND NAILED TO
FRAMING) - TYP @ EA SIDE OF GARAGE DOOR OPN'G
UNEXC
31/2" POURED
CONCRETE SLAB
ON GRADE
31/2" POURED
CONCRETE SLAB
ON GRADE
5
A617'-0"6'-1"5'-1"UNEXCAVATED
8" POURED CONC FDN WALL
w/ 2" RIGID INSULATION ON EXTERIOR
2" LEDGE FOR CONCRETE SLAB
20"x8"d FTG.
3'-6"x3'-6"x12"d FTG OFFICE: (952) 746-7702 | FAX: (952) 746-7703CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE:DRAWN BY: c 2023 BEHR DESIGN, INC.THIS DRAWING AND DESIGN LAYOUT IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN CONSENT FROM BEHR DESIGN, INC.PROJECT FILE: BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.S1
Foundation PlanPinnacle Family HomesCharleston Model5364 177th St.Lakeville, MNPeter K.9/19/202323-PFH 1/4" = 1'-0"S1
1FOUNDATION PLAN
UFER Ground
-Provide 20' Rebar in footing and stub
up near electrical service panel.
2
A6
16'-0"5'-10"28'-2"50'-0"20'-0"30'-0"21'-10"28'-2"50'-0"47'-8"2'-2"17'-0"11'-2"4'-6"12'-6"3'-9"6'-0"4'-2"4'-2"12'-7"
50'-0"
49'-10"
11'-10"14'-0"14'-0"7'-10"13'-0"4'-0"11'-2"2x6 BEARING WALL
(2) 2x10's(HDR)
(3) 13/4"x14"d LVL (DR)
(2) 13/4"x 91/2"d LVL (HDR)
TOP CHORD BEARING
TRUSS AT FLUSH BEAM
2x6 BEARING WALL
(2) 2x10's(HDR)(2) 2x10's(HDR)
(2) 13/4"x 91/2"d LVL (HDR)(2) 13/4"x 91/2"d LVL (HDR)
(2) 13/4"x 91/2"d LVL (FL)
31/2" POURED
CONCRETE SLAB
ON GRADE
31/2" POURED
CONCRETE SLAB
ON GRADE
5
A618"d FLOOR TRUSSES@ 19.2" O.C.18"d FLOOR TRUSSES@ 19.2" O.C.18"d FLOOR TRUSSES@ 19.2" O.C.18"d FLOOR TRUSSES@ 19.2" O.C.1'-10 1/2"16'-3"1'-9"8'-3"1'-10 1/2"OFFICE: (952) 746-7702 | FAX: (952) 746-7703CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE:DRAWN BY: c 2023 BEHR DESIGN, INC.THIS DRAWING AND DESIGN LAYOUT IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN CONSENT FROM BEHR DESIGN, INC.PROJECT FILE: BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.S2
First Floor Framing PlanPinnacle Family HomesCharleston Model5364 177th St.Lakeville, MNPeter K.9/19/202323-PFH 1/4" = 1'-0"S2
1MAIN FLR FRAMIMG PLAN
Smoke
-
2
A6
48'-0"2'-0"22'-0"28'-0"16'-0"6'-0"28'-0"50'-0"20'-0"30'-0"
50'-0"
50'-0"50'-0"11'-0"17'-0"2'-0"16'-0"2'-0"8'-0"2'-0"
11'-0"16'-0"13'-0"8'-0"
5'-6"6'-6"6'-0"2'-0"28'-0"22'-4"5'-8"11'-0"17'-0"2x6 BEARING WALL
(2) 2x10's(HDR)(2) 13/4"x 91/2"d LVL (HDR)(2) 13/4"x 91/2"d LVL (HDR)(2) 13/4"x 91/2"d LVL (HDR)
2x6 BEARING WALL
(2) 2x10's(HDR)(2) 2x10's(HDR)(2) 2x10's(HDR)(2) 2x10's(HDR)(2) 2x10's(HDR)
(2) 2x10's(HDR)(2) 2x10's(HDR)
(2) 13/4"x 91/2"d LVL (HDR)(2) 13/4"x117/8"d LVL (FL) (2) 13/4"x117/8"d LVL (DR) (2) 2x10's(HDR)
TOP CHORD BEARING
TRUSS AT FLUSH BEAM 3'-1"11'-1"2'-10"3'-9"7'-3"(2) 13/4"x 91/2"d LVL (FL)(2) 13/4"x 91/2"d LVL (FL)
(2) 13/4"x117/8"d LVL (HDR) (2) 13/4"x117/8"d LVL (HDR)
5
A6
(2) 2x10's(HDR)
FLOOR LINE ABOVE
6x6 TREATED POST
MONO TRUSSES TO HANG OFF
OF JOISTS CANT. 11 7/8" TJIJOISTS @ 16" O.C.11 7/8" TJIJOISTS @ 16" O.C.11 7/8" TJIJOISTS @ 16" O.C.11 7/8" TJIJOISTS @ 16" O.C.11 7/8" TJIJOISTS @ 16" O.C.MONO TRUSSES@ 24" O.C.ROOF TRUSSES@ 24" O.C.
ROOF TRUSSES@ 24" O.C.
2'-9 3/4"4'-0"
11 1/2"
2'-6" 2'-8"7'-11 1/2"1'-10 1/2" 5'-0"2'-6 3/4"9'-6"8'-2"OFFICE: (952) 746-7702 | FAX: (952) 746-7703CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE:DRAWN BY: c 2023 BEHR DESIGN, INC.THIS DRAWING AND DESIGN LAYOUT IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN CONSENT FROM BEHR DESIGN, INC.PROJECT FILE: BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.S3
Second Floor FramingPinnacle Family HomesCharleston Model5364 177th St.Lakeville, MNPeter K.9/19/202323-PFH 1/4" = 1'-0"S3
1UPPER FLR FRAMING PLAN
BWPs
Above
16
FAN
Smoke
CS-PFCS-PF CS-PF
8
2
A6 30'-0"48'-0"
10'-8"5'-0"10'-10"7'-0"14'-6"13'-2"4'-10"12'-0"2'-0"28'-0"30'-0"11'-2"16'-10"14'-0"34'-0"
48'-0"
6'-0"7'-0"8'-4"6'-0"6'-8"
7'-0"7'-0"4'-0"2'-0"
5'-6"5'-2"5'-5"5'-5"7'-1"7'-5"8'-1"3'-1"(2) 2x10's(HDR)(2) 13/4"x 91/2"d LVL (HDR)(2) 13/4"x 91/2"d LVL (HDR)(2) 13/4"x 91/2"d LVL (HDR)
(2) 13/4"x 91/2"d LVL (HDR)
(2) 2x10's(HDR)GIRDER TRUSS
2'-0"
12" BOX VAULT
5
A6
ROOF TRUSSES@ 24" O.C.ROOF TRUSSES@ 24" O.C.ROOF TRUSSES@ 24" O.C.ROOF TRUSSES@ 24" O.C.ROOF TRUSSES@ 24" O.C.OFFICE: (952) 746-7702 | FAX: (952) 746-7703CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE:DRAWN BY: c 2023 BEHR DESIGN, INC.THIS DRAWING AND DESIGN LAYOUT IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN CONSENT FROM BEHR DESIGN, INC.PROJECT FILE: BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.S4
Roof FramingPinnacle Family HomesCharleston Model5364 177th St.Lakeville, MNPeter K.9/19/202323-PFH 1/4" = 1'-0"S4
1ROOF FRAMING PLAN
-Min. 15" clearance to any
obstruction from center of
W.C., 24" in front(typ).
Temper if
within 60"
of tub floor.
Smoke
COSmoke
Smoke Smoke
Smoke
FAN
FAN
FAN
-
END CONDITION 1
BWL-1
BWL-228'-0"CS-WSP
4'-0"13'-10"
CS-WSP
4'-0"8'-4"
CS-WSP
4'-0"9'-10"
CS-WSP
4'-0"
48'-0"
END CONDITION 1BWL-BBWL-AEND CONDITION 1&4
BWL-1
BWL-2
BWL-3
48'-0"
CS-WSP
4'-0"15'-10"
CS-WSP
4'-0"20'-2"
CS-WSP
4'-0"22'-0"28'-0"CS-WSP4'-0"11'-4"CS-WSP8'-0"4'-8"CS-WSP
3'-10"9'-10"
CS-WSP
2'-10"4'-0"
DS-GB
16'-0"7'-8"
DS-GB
3'-4"2'-6"CS-WSP4'-0"14'-6 1/2"CS-WSP4'-0"7'-5 1/2"CS-WSP4'-0"12'-0"CS-WSP4'-0"20'-0"28'-0"CS-WSP4'-0"14'-0"CS-WSP4'-0"END CONDITION 1
END CONDITION 1
END CONDITION 1END CONDITION 1 CS-PF
1'-10"16'-4"
CS-PF
1'-8"8'-4"
CS-PF
1'-10"BWL-CBWL-ABWL-BBWL-ABWL-COFFICE: (952) 746-7702 | FAX: (952) 746-7703CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE:DRAWN BY: c 2023 BEHR DESIGN, INC.THIS DRAWING AND DESIGN LAYOUT IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN CONSENT FROM BEHR DESIGN, INC.PROJECT FILE: BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.S5
Braced Wall DetailsPinnacle Family HomesCharleston Model5364 177th St.Lakeville, MNPeter K.9/19/202323-PFH 3/16" = 1'-0"S5
1Braced Wall -Basement
3/16" = 1'-0"S5
2 Braced Wall -Main Floor
END CONDITION 1
BWL-1
BWL-228'-0"CS-WSP
2'-8"11'-6"
CS-WSP
4'-0"14'-1"
CS-WSP
4'-0"8'-2"
CS-WSP
3'-4"
48'-0"2'-0"CS-WSP4'-0"20'-0"CS-WSP4'-0"CS-WSP4'-0"20'-0"CS-WSP4'-0"CS-WSP
3'-10"16'-2"
CS-WSP
4'-0"20'-0"
CS-WSP
4'-0"
END CONDITION 1& 4
END CONDITION 1
END CONDITION 1 BWL-BBWL-AOFFICE: (952) 746-7702 | FAX: (952) 746-7703CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE:DRAWN BY: c 2023 BEHR DESIGN, INC.THIS DRAWING AND DESIGN LAYOUT IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN CONSENT FROM BEHR DESIGN, INC.PROJECT FILE: BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.S6
Braced Wall PlansPinnacle Family HomesCharleston Model5364 177th St.Lakeville, MNPeter K.9/19/202323-PFH 3/16" = 1'-0"S6
1 Braced Wall -Upper Floor
-SA/C HOOK UPSSS3 S
R
F
P
S3S S3S
R R
OUTLET FOR
GARAGE OPENER
OUTLETS PER CODE
S3S
SSS
S S
FIREPLACE
S3S3S3R
RR
DW
GARBAGE
DISPOSAL
SS
R
R
R
P
P
SSS
S3R
SPANEL
OUTLETS PER CODE
F
FAN W/LIGHT
FAN W/LIGHTS3S3SSSS
S
S
S S S
SSSSS
S
W.
D.
PUCK
LIGHTS3 S3
S3S OFFICE: (952) 746-7702 | FAX: (952) 746-7703CELL: (952) 994-6682 | E-MAIL: mikeb@behr-design.comSHEET NO.DATE:DRAWN BY: c 2023 BEHR DESIGN, INC.THIS DRAWING AND DESIGN LAYOUT IS PROTECTED UNDER STATE AND FEDERAL COPYRIGHT LAWS. IT MAY NOT BE REPRODUCED OR USED FOR ANY PURPOSE WITHOUT PRIOR WRITTEN CONSENT FROM BEHR DESIGN, INC.PROJECT FILE: BEHR DESIGN, INC. NOR ITS EMPLOYEES ASSUME ANY RESPONSIBILITY FOR VARIOUS CONSTRUCTION TECHNIQUES AND/OR QUALITY OF MATERIALS AND WORKMANSHIP. RESIDENTIAL DESIGNERS OR DRAFTSPERSONS ARE NOT ENGINEERS. BEHR DESIGN, INC. RECOMMENDS THAT A QUALIFIED, LICENSED STRUCTURAL ENGINEER BE RETAINED TO INSURE THE STRUCTURAL INTEGRITY OF ALL BUILDINGS. BEAMS AND STRUCTURAL MEMBERS SPECIFIED ON THESE PLANS ARE FOR BID PURPOSE ONLY AND SHOULD BE SIZED BY THE MANUFACTURERS ENGINEERING STAFF AND/OR A LICENSED ENGINEER. SIZES OF MATERIALS AND PRODUCTS SPECIFIED ON THESE PLANS REFLECT ACCEPTED INDUSTRY STANDARDS AND IN NO WAY INDICATE A SPECIFIC MANUFACTURER, UNLESS REQUESTED BY THE CLIENT. IN THE CASE OF DOORS AND WINDOWS, GENERIC SIZES ARE SPECIFIED UNLESS NOTED OTHERWISE AND IT IS ASSUMED THAT THE SUPPLIER WILL BID AND USE THE CLOSEST SIZE AVAILABLE. THE GENERAL CONTRACTOR AND/OR HOMEOWNER SHALL ASSUME FULL RESPONSIBILITY FOR THE CHECKING AND VERIFICATION OF DIMENSIONS, DETAILS, AND NOTES, AS WELL AS CONSTRUCTION TECHNIQUES, SPECIFICATIONS, STRUCTURAL AND/OR SAFETY REQUIREMENTS AND CONFORMITY TO ALL FEDERAL, STATE AND LOCAL BUILDING CODES, LAWS AND ORDINANCES. HOMES WHICH ARE TO BE CONSTRUCTED IN AREAS THAT ARE SUBJECT TO EXTRAORDINARY SEISMIC, WIND, SNOWFALL, COLD OR FLOOD ISSUES SHOULD BE ENGINEERED AND INSPECTED BY A CONSTRUCTION PROFESSIONAL FAMILIAR WITH THE PARTICULAR CONDITIONS OF THAT REGION. THESE PLANS SHALL REMAIN THE PROPERTY OF BEHR DESIGN, INC., SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF BEHR DESIGN, INC. OR THE CLIENT FOR WHICH THEY WERE PREPARED FOR.E1
Electrical PlansPinnacle Family HomesCharleston Model5364 177th St.Lakeville, MNPeter K.9/19/202323-PFH 3/16" = 1'-0"E1
1Electrical -Basement Plan
3/16" = 1'-0"E1
2 Electrical -Main Floor
3/16" = 1'-0"E1
3 Electrical -Upper Floor Plan
40,000
X
X
40,000
40,000
3000
3000
3000
40,000
40,000 13.33
13.33
88,000
1144
1144 .38
.38 .62
.62 8.26
3.2
240
375
375
3916
587
587
-212
NR
170
85