Loading...
HomeMy WebLinkAboutsurvey freestanding signSteel Tube Post with Surrounding Brick Structure -32"- fl1 Construction Aluminum Construction Cabinet White Lexan Pan Faces White LED's Prefinish Metal Frame -39" 39" 150" 150" g gaadwill GOODWILL ffl Graphics Vinyl Graphics 230-Dark Blue Transulcentto MatchPMS Reflex Blue UBlack Translucent [ii I n sta II Need Engineering for Base 240" DATE 8.9.2023 CLIENT GOODWILL - Lakeville SIGN TYPE Pylon Sign - Pan Face or a Flex face QUANTITY 1 DIS TYPESET Helvetica Bold Condensed LINE ADVE R T I S I N G 16703 Aberdeen St. NE Ham Lake MN 55304 763.428.5067 www. top lines i g n. com LA218207 12'-6"2'-8" TYP. 15'-2" O.C. 3'-3" TYP. MASONRY BASE BY OTHERS CABINET 8 STD. PIPE OD: 8.63" WALL: 0.322" TYP.4'-0"±20'-10" OAH8'-0"20'-0"18'-6"X5'-0"X4'-0" DEEP SPREAD FOOTING W/ #4 @12" O.C. EACH WAY TOP & BOTTOM MAT18'-6" ELEVATION1-6"14'-4"11545 W. BERNARDO COURT, SUITE 201 SAN DIEGO, CA 92127 PROJECTMANAGER@SULLAWAYENG.COM PHONE: 1-858-312-5150 FAX: 1-858-777-3534 PROJECT: PROJECT #: CLIENT: DATE: ENGINEER: LAST REVISED: GOODWILL, 11578 207TH STREET W., LAKEVILLE, MN 41788 SIGN ART USA 08/11/2023 PRC GENERAL NOTES 1. DESIGN CODE: : IBC 2018 & MINNESOTA STATE BC 2020 2. DESIGN LOADS: ASCE 7-16 3. WIND VELOCITY 110 MPH EXPOSURE C 4. CONCRETE 2500 PSI MINIMUM 5. PIPE STEEL ASTM A53 GR. B, Fy = 35 KSI MIN. 6. STEEL REINFORCEMENT IN CONCRETE ASTM A615 GR 60 7. PROVIDE MIN. 3" CLEAR COVER ON ALL STEEL EMBEDDED IN CONCRETE WHEN CAST AGAINST SOIL 8. VERTICAL SOIL BEARING PER IBC CLASS 4 (2000 PSF) 9. PROVIDE PROTECTION AGAINST DISSIMILAR METALS 10. ALL DIMENSIONS TO BE VERIFIED PRIOR TO FABRICATION Page 1 of 3 PROJECT: GOODWILL DATE: 08/11/23 PROJ. NO.: 41788 ENGINEER: PRC CLIENT: SIGN ART USA V5.5 units; pounds, feet unless noted otherwise Applied Wind Loads; from ASCE 7-16 F=qz*G*Cf*Af with qz = 0.00256KzKztKdV2 (29.3.2 & 29.4) Cf=1.708 (Fig. 29.3-1) 2 pole Cf factor= 0.97 15.1667 max. height= 20.833 1.0 Kzt=1.0 (26.8.2) (=1.0 unless unusual landscape)s= 8.00 Kz=from table 28.3-1 Exposure= c 2 Kd=0.85 for signs (table 26.6-1) Lz= V= 110 mph G= 0.85 (26.9)weight= 2.108 kips s/h= 0.384 MDL=0.00 k-ft (see Page #3) B/s= 1.56 Pole structure height at Wind Loads component section c.g Kz qz Af shear Moment MW 1 6.00 0.85 22.38 64.00 2080 12480 2 13.50 0.85 22.38 53.50 1739 23473 3 17.50 0.88 23.06 89.17 2987 52264 4 20.42 0.90 23.82 4.17 144 2943 sums: 210.83 6949 91.16 (Mw)ŬͲĨƚ arm= 13.1 two pole distribution factor *b*s (asce fig. 29.4-1 ):x 0.57 3931 51.56 Pu=2.53 kip M= 51.56 k-ft M=sqrt(MDL 2+Mw 2) Mu=sqrt(1.2MDL 2+1.0MW 2) =51.56 k-ft Pole Design section; pipe Mu < IMn with Mn = fyZfy=35 ksi ϕ=0.9 H Mu(k-ft)t (in) Z hƐĞ at grade 51.56 0.322 20.80 8 Std. Pipe, ϕMn = 54.6 k-ft Footing Design footprint:round Z=1.3 IBC 1605.3.2 IBC Table 1806.2, sections 1806.3.4, 1807.3.2 S=(1.3x2x150psf/ft) P=3.07 kip S1 = S x d / 3 A = 2.34 x P / (S1 x b) S= 400 S1=1133 d =0.5xA (1+ (1+4.36x h/A) ^.5) IBC 1807.3.2.1 A=3.17 footing:2' - 0" dia. 8' - 6" deep Z req'd. (in) Size(in) 19.64 8 32.50 pressure qz*G*Cf 32.50 33.49 34.59 Page 2 of 3 PROJECT: GOODWILL DATE: PROJ. NO.: 41788 ENGINEER: CLIENT: SIGN ART USA V5.5 units; pounds, feet unless noted otherwise Longitude Direction applied shear at grade v=4.343 kip unfactored load 6.949 k (factored) applied moment at grade m=56.97 kip-ft unfactored load 91.16 k-ft (factored) depth of soil above footing hs=0.00 ft allowable soil bearing p=2.000 ksf (i.e., 2000 x 1.333 = 2667 psf) (use a factor of 1.33 for wind or seismic) Signage Weight w1 =2.108 k (See Page #2) Brick Weight w2 =12.740 k ((2'-8")*(2'-8")*(14'-4")*0.125k/ft^3) Spread Footing Design moment m= 74.35 k-ft Footing size (ft) b=18.50 L=5.00 h=4.00 S= 77.1 Footing Weight= 55.5 k See Above ,w1+w2=14.849 k soil 0.00 total= 70.35 Overturning;Mcс 175.87 Mcхϭ͘ϱD 2.366 ok soil pressure; max= 1.757 ksf min= -0.2 ksf ok forces on concrete pad; V= 57.47 k Vrс 91.96 k (=1.6V) M=71.84 k-ft Mrс 114.95 k-ft Check Slab; ϕ=0.9 fy=60 ksi fc=2.5 ksi 150 lbs/ft3 Flexure Asс 0.600 d= 44.0 in IMn=IAsfy(d-a/2)=1424 k-in = 118.70 k-ft MrIMn ok a=Asfy/0.85fcb=0.076 in Check minimum Asmin=3sqrt(fc)bd/fy =24.42 200bd/fy=32.56 or 1.333As=0.80 in2 ACI 10.3.1 Use As=0.80 in2 short direction JsсϮͬ;E нϭͿс 0.8 with E с 1.5 short direction;Jsс 0.64 in2 Use #4@12" each direction Shear;IsnсIϮƐƋƌƚ;ĨcͿďĚ Iscс ϕ=0.75 VrIVn ok Top Slab Assume half of footing is in uplift weight= 27.75 kip arm= 1.25 ft M= 34.69 k-ft Mrс 41.63 k-ft Flexure Asс 0.300 IMn=IAsfy(d-a/2)=711.66 k-in = 59.305 k-ft MrIMn ok a=Asfy/0.85fcb=0.141 in Check minimum Asmin=2sqrt(fc)bd/fy =6.6 200bd/fy=8.80 or 1.333As=0.4 in2 Use As=0.40 in2 short direction JsсϮͬ;E нϭͿс 0.8 with E с 1.5 short direction;Jsс 0.32 in2 Use #4@12" each direction 08/11/23 PRC 732.6 Page 3 of 3