HomeMy WebLinkAboutLA218920 - 19558 Harbor Dr Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
_____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
NAME OF APPLICANT (Please Print)DATE
I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS
APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO
COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH
LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED
PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE
CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE
ESCROW APPLICATION AND REFUND.
OFFICE PHONE #:_
OFFICE PHONE #:_
*Entering your name affirms your intent to comply with the statement above.
*
Submit Application To: permits@lakevillemn.gov
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT
CONDO
REROOF
RESIDE
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES
LOWER LEVEL FINISH
ADDITION
FOUNDATION ONLY
MISCELLANEOUS
DEMO
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
CITY BUILDING VALUATION: $
BUILDING PERMIT FEES
$PERMIT FEE
$PLAN CHECK
$SURCHARGE
$METRO SAC
$CITY WATER HOOKUP UNIT
$CITY SEWER HOOKUP UNIT
$LANDSCAPE ESCROW
$TREE ESCROW
$MISC ESCROW
$PLUMBING
$MECHANICAL
$SEWER WATER
WATER METER
PRESSURE REDUCING VALVE
$OTHER
$TOTAL
METER SIZE
PRESSURE REDUCING VALVE
SEWER/WATER
SEWER/WATER
FINAL
STREET DRAINTILE
BUILDING INFORMATION
TYPE OF CONSTRUCTION
ZONING
CODE EDITION
FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
MECHANICAL
AIR TEST
FINAL
ROUGH-IN
PLUMBING
FINAL
ROUGH-IN
INSULATION
LATH
DECK FOOTING
FIREPLACE
FOOTING
FOUNDATION
FRAMING
PORCH FRAMING
PORCH FOOTING
POURED WALL
SITE
LOWER LEVEL FINAL
OTHER
DECK FRAMING
LOWER LEVEL FRAMING
LANDSCAPING
DECK FINAL
$
$
ACCESSORY BUILDING
EGRESS WINDOW
UNDERGROUND
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:04:45 PM01 Front PersepctivePFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05W H I T E O A K M O D E L
BERRES RIDGE 8th ADDITION
BLOCK 02 LOT 05
LAKEVILLE, MN 55044
S H E E T L I S T
Number Name
01 Front Persepctive
02 Rear Perspective
03 Front & Rear Elevations
04 Left & Right Elevations
05 Ext. Attachement Details
06 Roof Plan
07 Foundation Plan
08 Foundation Details
09 Lower Level
10 Lower Level Structural
11 Lower Level Recessed Can Layout
12 Main Level
13 Main Level Structural
14 Main Level Recessed Can Layout
15 Upper Level
16 Upper Level Structural
17 Upper Level Recessed Can Layout
18 Cross Sections
19 Cross Sections
20 Cross Sections
21 Schedules & Details
22 Square Footage Calculations
Grand total: 22
REVISION SCHEDULENumberDate Issued by
Concept Approval ONLY
Subject to Field Inspection
Inspector Date
2020
MN Bldg
Code
10/11/2023dmathews
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:04:53 PM02 Rear PerspectivePFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05W H I T E O A K M O D E L
BERRES RIDGE 8th ADDITION
BLOCK 02 LOT 05
LAKEVILLE, MN 55044 REVISION SCHEDULENumberDate Issued by
Deck not part of
permitted project per
applicatnt 10/5/23
First Floor0' - 0"
Second Floor10' - 7 7/8"
Roof18' - 9"
Basement-10' - 4 3/4"
T.O. Footing-10' - 8 1/4"
B.O. Footing-11' - 4 1/4"
Top of Foundation-1' - 8 1/4"
First Floor Clg.9' - 1 1/8"
Basement Clg.-1' - 6 3/4"
Roof Peak25' - 8 5/8"
Grade-2' - 2 1/4"Upper Level Clg. Hgt.8' - 1 1/8"1' - 6 3/4"Main Level Clg. Hgt.9' - 1 1/8"1' - 6 3/4"Lower Level Clg. Hgt8' - 10"Typical Foundation Wall Hgt.9' - 0"Upper Level Wdw Frame Hgt.7' - 0"Main Level Wdw Frame Hgt.8' - 0"Lower Level Wdw Frame Hgt.7' - 0"8' - 0"A
A
AAA
AA
B
B
B
C
C
C
CCC
C
C
5/4" X 6" TRIM BD.5/4" X 6" TRIM BD.
5/4" X 6" TRIM BD.
DD
2-1/4" SLOPED STONE CAP
2-1/4" SLOPED STONE CAP
/(SEE 3 A20)
/(SEE 2 A20)
12"96"6 1/2"
10' - 0"/(SEE 3 A18)/(SEE 3 A18)
10"x10" TIMBER BEAM
2)10"x10" TIMBER COLUMNS
111
103102
35313034 37 38
36
32
2018
1917
1413
101
19
4
SIMPSON MSTC36 STRAP @ ROOF LINE TYP.
SIMPSON MSTC36
STRAP @ ROOF LINE
TYP.
SIMPSON MSTC42 STRAP @ FLOOR LEVEL TYP.
SIMPSON MSTC42 STRAP @ FLOOR LEVEL TYP.
A
AA A
A
A
AAA
A
A
5/4" X 6" TRIM BD.5/4" X 6" TRIM BD.
5/4" X 6" TRIM BD.
5/4" X 6" TRIM BD.
5/4" X 6" TRIM BD.
5/4" X 6" TRIM BD.
5/4" X 6" TRIM BD.
5/4" X 12" TRIM BD.
CC
01 01 02 02
23 24 26
08 10 08
07 09 07
0404
0303
108
001
AC PROPOSED LOCATION
SIMPSON MSTC36 STRAP @ ROOF LINE TYP.
SIMPSON MSTC42 STRAP @
FLOOR LEVEL TYP.DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:01 PM03 Front & Rear ElevationsPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05STONE ATTACHMENT
1. VERIFY COMPLIANCE WITH INSPECTOR WHEN PAPER IS COMPLETE IN ONE WINDOW AREA.
2. WEATHER RESISTIVE BARRIERS:INCLUDE 2 LAYERS OF GRADE D PAPER WITH WEATHER RESISITVE BARRIERS OVER WOOD BASED SHEATHING. 15 OR 15# IS NOT GRADE D PAPER. LAP VERTICAL JOINTS IN PAPER AT LEAST 2 INCHES.
3. EXTERIOR OPENINGS FLASHED:FLASH ALL EXTERIOR OPENINGS. THE NAILING FLANGE ON WINDOWS WILL NOT BE ACCEPTED FOR FLASHING UNLESS THE MANUFACTURERS INSULATION INSTRUCTIONS ARE PROVIDED ON SITE STATING THE FLANGE IS ACCEPTABLE AS FLASHING.
4. WINDOW FLANGES:INSTALL PAPER ON BOTTOM AND SIDES OF WINDOW BEFORE INSTALLING WINDOW. PAPER LOCATED ON TOP OF WINDOW SHALL GO OVER THE WINDOW FLASHING. INSTALL A SECOND LAYER OF PAPER OVER SIDE WINDOW FLANGES.
5. WINDOW OPENINGS:WATERPROOF WINDOW OPENINGS WITH CAULK, TAPE, OR LIKE MATERIAL. ALL OTHER OPENINGS MUST BE WATERPROOFED WITH CAULK, TAPE, OR LIKE MATERIAL.
6. PAPER ENTIRE WALL:BUILDING PAPER MUST BE INSTALLED ON ALL EXTERIOR WALLS INCLUDING WITHIN THE SOFFIT. INSTALL PAPER IN SHINGLE FASHION TO ENSURE PROPER WATER DRAINIAGE.
7. FLASHING:AT ALL WALL/ROOF INTERSECTIONS WHERE ROOF LINE DOES NOT EXTEND PAST WALL, KICKOUT FLASHING IS REQUIRED. ALL OTHER OPENINGS MUST BE FLASHED TO ENSURE PROPER WATERPROOFING.
8. WEEP SCREED:PROVIDE A CORROSION RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2" AT OR BELOW THE FOUNDATION PLATE. TO ENSURE TRAPPED WATER HAS PROPER DRAINAGE TO EXTERIOR, SCREED SHALL BE A TYPE THAT ALLOWS FOR DRAINAGE AND MUST BE PLACED A MINIMUM OF 4" ABOVE EARTH OR 2" ABOVE CONCRETE. PLACE WEEP SCREEDS JUST BELOW PLATE LINE. IF PAPER HAS BEEN INSTALLED ON FOUNDATION, EXTEND WEEP SCREED ONTO FOUNDATION. ALL STONE MUST NOT EXTEND BELOW, BUT MUST COVER, ALL LATH AND PAPER.
DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR STONE INSTALLATION OR WATERPROOFING TECHNIQUES.
REFER TO MANUFACTURER AND INSTALLERS FOR PREFERRED INSTALLATION METHODS WHICH WILL DIFFER FROM WHAT IS SHOWN.
FOUNDATION WALL HEIGHTS ARE SUBJECT TO CHANGE DUE TO GRADE AND SITE CONDITIONS.
ALL FOUNDATION WALL HEIGHTS MUST BE VERIFIED ON SITE BY THE CONTRACTOR AND SITE SURVEYOR PRIOR TO CONSTRUCTION.
FOUNDATION CONTRACTOR WILL STEP FOUNDATION WALLS AS NECESSARY TO MAINTAIN PROPER FROST PROTECTION (42" BELOW GRADE) IN ACCORDANCE TO CURRENT MINNESOTA CODE, REGULATIONS, AND ZONING.
FOUNDATION WALLS DISCLOSURE:
1/4" = 1'-0"
1 Front Elevation
1/4" = 1'-0"
2Rear Elevation
TYPICAL EXTERIOR MATERIALS
ASPHALT SHINGLES W/ NATURAL SHADOW ARCHITECTURAL GRADE
6" EXPOSURE HARDIELAP SIDING PER ELEVATION
6" EXPOSURE NICHIHA NICHIBOARD SIDING PER ELEVATION
HARDIEPANEL SMOOTH w/FRY REGELT DETAILS (a05) PER ELEVATION
2" STONE VENEER PER ELEVATION
CORNER WINDOW TRIM DETAIL SUPPLIED BY WINDOW MFG.SEE DETAIL 01/a05
INSTALL KICK OUT FLASHING & TWO MEMBRANE TAR PAPER BACKING IN ALL STONE AREAS
5/4" x 2" HARDIE WINDOW & DOOR WRAPS PER ELEVATION
SERIES 199 METAL CORNERS PER ELEVATION
1X8 HARDIE FASCIA w/5"x5" SQUARE GUTTERS & DOWNSPOUTS PER ELEVATION
HARDIE VENTED SOFFITS PER ELEVATION
EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION
HOUSE WRAP AND/OR TAR PAPER IN PROPER FORM ON ENTIRE EXTERIOR
B
C
D
A
SEE "TYPICAL EXTERIOR MATERIALS" FOR ALL CLADDING SHOWN
SEE FINAL PAGE FOR SQUARE FOOTAGE CALCULATIONS
METAL FASCIAS AND ROOFS HAVE THE TENDENCY TO OIL CAN UNDER CERTAIN WEATHER CONDITIONS. CONSULT CONTRACTOR FOR METAL GAUGE THICKNESS OPTIONS TO REDUCE WEATHER RELATED CONCERNS (BUBBLING, WARPING, ETC.)
GENERAL CONTRACTOR TO ENSURE THAT ALL ROOF PENETRATIONS (VENT PIPES, EXHAUST FANS, FURNACE/AC PIPES, ETC) ARE PLACED IN INCONSPICUOUS LOCATIONS ON ROOF TO MINIMIZE THE SIGHT OF PENETRATIONS FROM MAIN ARCHITECTURAL VIEWS OF HOME.
DAVID CHARLEZ DESIGNS RECOMMENDS MASONRY CONCRETE LEDGES FOR ALL EXTERIOR MASONRY CLADDING PRODUCTS. WHEN MASONRY CONCRETE LEDGES ARE NOT PROVIDED PER GENERAL CONTRACTOR ’S REQUEST, DAVID CHARLEZ DESIGNS DOES NOT ACCEPT RESPONSIBILITY FOR ANY EXTERIOR MASONRY CLADDING FAILURES.
elevation notes:REVISION SCHEDULENumberDate Issued by
A
A
AA
AA
A
B
B
C
5/4" X 6" TRIM BD.
5/4" X 6" TRIM BD.
5/4" X 6" TRIM BD.5/4" X 12" TRIM BD.
39
22
5/4" X
6
"
T
R
I
M
B
D
.
SIMPSON MSTC36 STRAP @ ROOF LINE TYP.
SIMPSON MSTC42 STRAP @ FLOOR LEVEL TYP.
A
5/4" X 6" TRIM BD.
41 40
AAA
AA
AAA
A
A A
A
C
C
C
5/4" X 6" TRIM BD.5/4" X 6" TRIM BD.
5/4" X 6" TRIM BD.
5/4" X 6" TRIM BD.
5/4" X 6" TRIM BD.5/4" X 12" TRIM BD.
/(SEE 3A18)
2527 28 29 33
12 16
15
11 11
06
05
5/4" X 6" TR
I
M
B
D
.
SIMPSON MSTC36 STRAP @ ROOF LINE TYP.
SIMPSON MSTC42 STRAP @ FLOOR LEVEL TYP.
SIMPSON MSTC36 STRAP @ ROOF LINE TYP.
SIMPSON MSTC42 STRAP @ FLOOR LEVEL TYP.DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:09 PM04 Left & Right ElevationsPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05TYPICAL EXTERIOR MATERIALS
ASPHALT SHINGLES W/ NATURAL SHADOW ARCHITECTURAL GRADE
6" EXPOSURE HARDIELAP SIDING PER ELEVATION
6" EXPOSURE NICHIHA NICHIBOARD SIDING PER ELEVATION
HARDIEPANEL SMOOTH w/FRY REGELT DETAILS (a05) PER ELEVATION
2" STONE VENEER PER ELEVATION
CORNER WINDOW TRIM DETAIL SUPPLIED BY WINDOW MFG.SEE DETAIL 01/a05
INSTALL KICK OUT FLASHING & TWO MEMBRANE TAR PAPER BACKING IN ALL STONE AREAS
5/4" x 2" HARDIE WINDOW & DOOR WRAPS PER ELEVATION
SERIES 199 METAL CORNERS PER ELEVATION
1X8 HARDIE FASCIA w/5"x5" SQUARE GUTTERS & DOWNSPOUTS PER ELEVATION
HARDIE VENTED SOFFITS PER ELEVATION
EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION
HOUSE WRAP AND/OR TAR PAPER IN PROPER FORM ON ENTIRE EXTERIOR
B
C
D
A
STONE ATTACHMENT
1. VERIFY COMPLIANCE WITH INSPECTOR WHEN PAPER IS COMPLETE IN ONE WINDOW AREA.
2. WEATHER RESISTIVE BARRIERS:INCLUDE 2 LAYERS OF GRADE D PAPER WITH WEATHER RESISITVE BARRIERS OVER WOOD BASED SHEATHING. 15 OR 15# IS NOT GRADE D PAPER. LAP VERTICAL JOINTS IN PAPER AT LEAST 2 INCHES.
3. EXTERIOR OPENINGS FLASHED:FLASH ALL EXTERIOR OPENINGS. THE NAILING FLANGE ON WINDOWS WILL NOT BE ACCEPTED FOR FLASHING UNLESS THE MANUFACTURERS INSULATION INSTRUCTIONS ARE PROVIDED ON SITE STATING THE FLANGE IS ACCEPTABLE AS FLASHING.
4. WINDOW FLANGES:INSTALL PAPER ON BOTTOM AND SIDES OF WINDOW BEFORE INSTALLING WINDOW. PAPER LOCATED ON TOP OF WINDOW SHALL GO OVER THE WINDOW FLASHING. INSTALL A SECOND LAYER OF PAPER OVER SIDE WINDOW FLANGES.
5. WINDOW OPENINGS:WATERPROOF WINDOW OPENINGS WITH CAULK, TAPE, OR LIKE MATERIAL. ALL OTHER OPENINGS MUST BE WATERPROOFED WITH CAULK, TAPE, OR LIKE MATERIAL.
6. PAPER ENTIRE WALL:BUILDING PAPER MUST BE INSTALLED ON ALL EXTERIOR WALLS INCLUDING WITHIN THE SOFFIT. INSTALL PAPER IN SHINGLE FASHION TO ENSURE PROPER WATER DRAINIAGE.
7. FLASHING:AT ALL WALL/ROOF INTERSECTIONS WHERE ROOF LINE DOES NOT EXTEND PAST WALL, KICKOUT FLASHING IS REQUIRED. ALL OTHER OPENINGS MUST BE FLASHED TO ENSURE PROPER WATERPROOFING.
8. WEEP SCREED:PROVIDE A CORROSION RESISTANT WEEP SCREED WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2" AT OR BELOW THE FOUNDATION PLATE. TO ENSURE TRAPPED WATER HAS PROPER DRAINAGE TO EXTERIOR, SCREED SHALL BE A TYPE THAT ALLOWS FOR DRAINAGE AND MUST BE PLACED A MINIMUM OF 4" ABOVE EARTH OR 2" ABOVE CONCRETE. PLACE WEEP SCREEDS JUST BELOW PLATE LINE. IF PAPER HAS BEEN INSTALLED ON FOUNDATION, EXTEND WEEP SCREED ONTO FOUNDATION. ALL STONE MUST NOT EXTEND BELOW, BUT MUST COVER, ALL LATH AND PAPER.
DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR STONE INSTALLATION OR WATERPROOFING TECHNIQUES.
REFER TO MANUFACTURER AND INSTALLERS FOR PREFERRED INSTALLATION METHODS WHICH WILL DIFFER FROM WHAT IS SHOWN.
FOUNDATION WALL HEIGHTS ARE SUBJECT TO CHANGE DUE TO GRADE AND SITE CONDITIONS.
ALL FOUNDATION WALL HEIGHTS MUST BE VERIFIED ON SITE BY THE CONTRACTOR AND SITE SURVEYOR PRIOR TO CONSTRUCTION.
FOUNDATION CONTRACTOR WILL STEP FOUNDATION WALLS AS NECESSARY TO MAINTAIN PROPER FROST PROTECTION (42" BELOW GRADE) IN ACCORDANCE TO CURRENT MINNESOTA CODE, REGULATIONS, AND ZONING.
FOUNDATION WALLS DISCLOSURE:
1/4" = 1'-0"
1Right Elevation
1/4" = 1'-0"
2Left Elevation
SEE "TYPICAL EXTERIOR MATERIALS" FOR ALL CLADDING SHOWN
SEE FINAL PAGE FOR SQUARE FOOTAGE CALCULATIONS
METAL FASCIAS AND ROOFS HAVE THE TENDENCY TO OIL CAN UNDER CERTAIN WEATHER CONDITIONS. CONSULT CONTRACTOR FOR METAL GAUGE THICKNESS OPTIONS TO REDUCE WEATHER RELATED CONCERNS (BUBBLING, WARPING, ETC.)
GENERAL CONTRACTOR TO ENSURE THAT ALL ROOF PENETRATIONS (VENT PIPES, EXHAUST FANS, FURNACE/AC PIPES, ETC) ARE PLACED IN INCONSPICUOUS LOCATIONS ON ROOF TO MINIMIZE THE SIGHT OF PENETRATIONS FROM MAIN ARCHITECTURAL VIEWS OF HOME.
DAVID CHARLEZ DESIGNS RECOMMENDS MASONRY CONCRETE LEDGES FOR ALL EXTERIOR MASONRY CLADDING PRODUCTS. WHEN MASONRY CONCRETE LEDGES ARE NOT PROVIDED PER GENERAL CONTRACTOR ’S REQUEST, DAVID CHARLEZ DESIGNS DOES NOT ACCEPT RESPONSIBILITY FOR ANY EXTERIOR MASONRY CLADDING FAILURES.
elevation notes:REVISION SCHEDULENumberDate Issued by
FRAMED CORNER
WINDOW MANUFACTURE TO SUPPLY CORNER CLADDING FOR CORNER WINDOW DESIGN(MATCH WINDOW CLADDING COLOR & ASSEMBLY OF CORNER MAY VARY PER MANUFACTURE INSTALL PER MFG. SPEC.)
WEATHER RESISTANT BARRIER
FRAMING MEMBER
NICHIHA ULTIMATE CLIP LOCATED ON STUD
SHEATHING
SCALE: 1 1/2" = 1'-0"
MIN. 2" ABOVE HARD SURFACE OR MIN. 6" ABOVE FINAL GRADE (FINAL GRADE VARIES)
NICHIHA - HORIZONTAL AWP - WALL SECTION - SOFFIT
STARTERTRACK DETAIL
SUPPORT CLIPDETAIL
TOP OF WALL DETAIL
1.
2.
3.
4.
5.
NOTES:
THIS CONCEPTUAL DETAIL IS A GUIDE FOR INSTALLATION OF NICHIHA PRODUCTS. ARCHITECTS/ENGINEERS/CONTRACTORS ARE RESPONSIBLE FOR SUCCESSFUL APPLICATION WHICH DEPENDS UPON SUBSTRATE DESIGN AND CONSTRUCTION BUILT IN ACCORDANCE WITH BEST PRACTICES AND LOCAL BUILDING CODES.SHEATHING REPRESENTED HERE IS 5/8" EXTERIOR GYPSUM WALLBOARD, IF USING OSB OR PLYWOOD ADJUST ACCORDINGLY.WOOD OR METAL FRAMING (METAL FRAMING MEMBERS MUST BE A MINIMUM OF 18 GA.)NICHIHA PANEL (REPRESENTED HERE IS 5/8" NICHIHA PRODUCT, ADJUST ACCORDINGLY FOR OTHER NICHIHA PRODUCT THICKNESSES).FOLLOW WEATHER RESISTANT BARRIER BEST PRACTICES INSTRUCTIONS.
NICHIHA STARTER TRACK FASTENER LOCATED ON STUD
FACE FASTENER THROUGH PRE-DRILLED HOLES
0' - 2"0' - 6"NICHIHA 10MM SPACER
FASTENERS APPLIED TO FRAMING
NICHIHA ESSENTIAL STARTER FLASHING
NICHIHA PANEL
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:10 PM05 Ext. Attachement DetailsPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05NOT TO SCALE
2" Stone Installation Details
NOT TO SCALE
Fry Reglet Panel Details
NOT TO SCALE
1Detail - Corner Window Cladding Installation
1 1/2" = 1'-0"
Nichia Installation Detail REVISION SCHEDULENumberDate Issued by
48"48"24"24"
24"24"48"48"48"48"12"24"24"
24"24"24"
48"48"12"48"48"16' - 0"4" / 12"4" / 12"
4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"
4" / 12"
4" / 12"1/4" / 12"1/4" / 12"
RIDGE VENT
RIDGE VENTRIDGE VENTCROSS HATCH INDICATES 1/4" / 12" FLAT ROOF CONSTRUCTION BELOW OVERHANG
10 3/4"43 1/4"36"156"
13' - 10 3/4"
LOW SLOPE ROOFING DISCLOSURE:
CLIMATE CONDITIONS IN MN CAN MAKE LOW SLOPE ROOFING CONDITIONS CHALLENGING FOR TYPICAL ASPHALT SHINGLES APPLICATIONS. THE DESIGNER OF THIS HOME DOES NOT RECOMMEND USING ASPHALT SHINGLES FOR ROOF SLOPES WITH LESS THAN 4/12 PITCH. STANDING SEAM METAL ROOFS DESIGNED FOR LOW SLOPE APPLICATIONS WOULD BE PREFERRED. IF THE CLIENT CHOOSES TO USE ASPHALT SHINGLES, PLEASE FOLLOW THE MN DEPARTMENT OF LABOR AND INDUSTRY GUIDELINES FOR LOW SLOPE ASPHALT SHINGLES ROOF APPLICATIONS: WWW.DLI.MN.GOV/CCLD/PDF/EDU_ROOFING.PDF
SPECIAL UNDERLAYMENT TECHNIQUES, FLASHING, ETC. WILL BE REQUIRED
DESIGNER OF THE HOME DOES NOT MAKE ANY GUARANTEE FOR THE PERFORMANCE OF LOW SLOPE ASPHALT SHINGLES ROOF IN THE STATE OF MN.
10"x10" TIMBER POSTS 2' - 0"4" / 12"4" / 12"4"
12"
METAL DRIP EDGE
Overhang
24"
5/4"x6" TRIM BD
2x4 LOOKOUTS
COMPOSITE VENTED SOFFITS7 1/4"ARCHITECTURAL GRADE ASPHALT SHINGLES#15FELT & ICE & WATER SHIELD (6'-0")1/2" OSB SHEATHING w/STEEL CLIPSTRUSSES @ 24" O.C. (PER MFG. SPEC.)BAFFLES w/1" AIR SPACE2X4 LOOKOUTS2X8 SUB FASCIA w/ 4/4" x 8" COMPOSITE FASCIA COMPOSITE VENTED SOFFITSCOMPOSITE FRIEZE BOARDSR-50 BLOWN INSULATIONPOLY VAPOR BARRIER5/8" GYP. BRD. CEILINGE.H.7 13/16"ENERGY HEEL MAY VARY PER LOCATION
E.H.15 13/16"Overhang
48"
METAL DRIP EDGE
5/4"x6" TRIM BD
2x4 LOOKOUTS
COMPOSITE VENTED SOFFITS
ENERGY HEEL MAY VARY PER LOCATION
4"
12"
ARCHITECTURAL GRADE ASPHALT SHINGLES#15FELT & ICE & WATER SHIELD (6'-0")1/2" OSB SHEATHING w/STEEL CLIPSTRUSSES @ 24" O.C. (PER MFG. SPEC.)BAFFLES w/1" AIR SPACE2X4 LOOKOUTS2X8 SUB FASCIA w/ 4/4" x 8" COMPOSITE FASCIA COMPOSITE VENTED SOFFITSCOMPOSITE FRIEZE BOARDSR-50 BLOWN INSULATIONPOLY VAPOR BARRIER5/8" GYP. BRD. CEILING7 1/4"DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:15 PM06 Roof PlanPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05ENGINEERED ROOF TRUSSES PER MFG. SPEC. MANUFACTURE WILL PROVIDE ALL ENGINEERING DRAWING AND SPECIFICS
OVERHANG DIMENSIONS ARE TO FACE OF SHEATHING
ICE AND WATER ALL ADJOINING ROOFS
TRUSS MANUFACTURER TO VERIFY ALL ENERGY HEELS SHOWN TO ENSURE FINAL EAVE FRAMING DOES NOT CONFLICT WITH FINISHED EXTERIOR WINDOW TRIM AS SHOWN ON ELEVATIONS.
METAL FASCIAS AND ROOFS HAVE THE TENDENCY TO OIL CAN UNDER CERTAIN WEATHER CONDITIONS. CONSULT CONTRACTOR FOR METAL GAUGE THICKNESS OPTIONS TO REDUCE WEATHER RELATED CONCERNS (BUBBLING, WARPING, ETC.)
GENERAL CONTRACTOR TO ENSURE THAT ALL ROOF PENETRATIONS (VENT PIPES, EXHAUST FANS, FURNACE/AC PIPES, ETC) ARE PLACED IN INCONSPICUOUS LOCATIONS ON ROOF TO MINIMIZE THE SIGHT OF PENETRATIONS FROM MAIN ARCHITECTURAL VIEWS OF HOME.
roof plan notes:
1/4" = 1'-0"
1Roof Plan
1" = 1'-0"
2Detail - 24" Cornice
1" = 1'-0"
3Detail - 48" Cornice REVISION SCHEDULENumberDate Issued by
16' - 0"28' - 0"26' - 0"70' - 0"1' - 10 1/2"16' - 3" M.O.2' - 3"9' - 3" M.O.2' - 6 1/2"
8 1/2"M.O.
3' - 3"1' - 0 1/2"
32' - 2"5' - 0"12' - 0"14' - 10"
64' - 0"3' - 2"2' - 10"7' - 10"16' - 0"8' - 0"38' - 2"7' - 10"70' - 0"2"
20' - 0"16' - 9"7' - 7 1/4"4' - 7 3/4"14' - 10"
63' - 10"3 1/4"3 1/4"3 1/4"3 1/4"3 1/4"3 1/4"3 1/4"3 1/4"
2 3/4"2 3/4"2 3/4"2 3/4"2 3/4"2 3/4"4' - 0"12' - 0"- UNEXCAVATED -
- UNEXCAVATED -
2" SLAB LEDGE
2" SLAB LEDGE2" SLAB LEDGE2" SLAB LEDGE4"LEDGE(2" INSUL./2" SLAB)4" LEDGE(2" INSUL./2" SLAB)12' - 3"13' - 3"31' - 4"5' - 6 1/2"
3 1/2"
W.O.W.O.W.O.
11' - 0 1/2"8' - 0 3/4"5' - 6 3/4"7' - 10 1/2"4' - 5 1/2"20' - 3 1/4"7' - 10 1/4"12' - 2 1/4"1' - 7 3/4"5' - 3 1/4"
13' - 4 3/4"11' - 0 1/2"2' - 9 1/2"5' - 3 1/4"20' - 3 1/4"17' - 0 1/4"8' - 6 1/2"4" LEDGE(2" INSUL./2" SLAB)
4" LEDGE(2" INSUL./2" SLAB)53' - 10"MECH. F.D.
SHWR F.D.
SFTG #2
SFTG #1SFTG #1
SFTG #1SFTG #1SFTG #12" STONE LEDGE
F1
F1
F2
F2
F2
F3
F3
F5
F5
F5
F7
F7
F7
F7F8F8F9
F940' - 3 3/4"PIER #1PIER #1
PIER #1PIER #1
PIER #1PIER #1
PIER #1LINE OF DECK ABOVE
LINE O
F
P
A
TI
O
1
19
4
18
1
20
1
18
4
20
5
19
2
19
1
21
2
1810"10"10"8"
8"10"8"8"10"8"8"
8"8"8"8"8"10"10"8"8"
PFTG #1
PFTG #1PFTG #1PFTG #1PFTG #1PFTG #1PFTG #2
PFTG #2
CROSS HATCH INDICATES#5 L-BARS @ 24" O.C.
36"
36”
63' - 10"3 1/4"3 1/4"
PIER #1LINE OF DECK ABOVE18' - 10"15' - 10"9' - 2"20' - 0"
2"
2"
8"
F1
F2
2' - 2"29' - 2"6"27' - 6"foundation wall legend:
F1
9’-0” x 8” POURED CONCRETE WALL PULLED INTO HOUSE 2” (APPLY 2” CERTISTUDS IN AREAS w/ SLOPING GRADE FOR FLUSHED SIDING APPLICATION) ON20” x 8” CONCRETE FOOTING. REBAR PER CODE.- TYPICAL FOUNDATION WALL (MAINTAIN FROST PROTECTION)
N/A
9’-0” x 8” POURED CONCRETE WALL w/ 2” INTERIOR LEDGE (GARAGE SLAB) ON 20” x 8” CONCRETE FOOTING. REBAR PER CODE.- GARAGE / HOUSE COMMON WALL
9’-0” x 10” POURED CONCRETE WALL w/ 4” EXTERIOR LEDGE (2” SLAB, 2” INSULATION) ON 20” x 8” CONCRETE FOOTING REBAR PER CODE.- FRONT PORCH / HOUSE FOUNDATION WALL
-N/A-
3’-6” x 10” POURED CONCRETE WALL w/ 4” INTERIOR LEDGE (2" SLAB, 2" INSULATION) ON 20” x 8” CONCRETE FOOTING. REBAR PER CODE.- TYPICAL WALK-OUT FOUNDATION WALL #1
3’-6” x 12” POURED CONCRETE WALL w/ 4” INTERIOR LEDGE (2" SLAB, 2" INSULATION) ON 20” x 8” CONCRETE FOOTING. REBAR PER CODE.- TYPICAL WALK-OUT FOUNDATION WALL #2
3’-6” x 8” POURED CONCRETE WALL w/ 2” INTERIOR LEDGE (GARAGE SLAB) ON 20” x 8” CONCRETE FOOTING.REBAR PER CODE.- TYPICAL GARAGE FOUNDATION WALL #1
3’-6” x 10” POURED CONCRETE WALL w/ 2” EXTERIOR LEDGE (STONE) & 2” INTERIOR LEDGE (GARAGE SLAB) ON20” x 8” CONCRETE FOOTING. REBAR PER CODE.- GARAGE FOUNDATION w/STONE
3’-6” x 8” POURED CONCRETE WALL ON20” x 8” CONCRETE FOOTING. REBAR PER CODE.- TYPICAL FRONT PORCH FOUNDATION
F2
F3
F4
F5
F6
F7
F8
F9
SEE REINFORCING SCHEDULE A07
F1.A
concrete pad footing legend
PFTG #1 36”x36”x12” POURED CONCRETE PAD FOOTINGw/ 4) #5 BARS EACH WAY.
PFTG #2 42”x4212” POURED CONCRETE PAD FOOTINGw/ 5) #5 BARS EACH WAY.
concrete STRIP footing legend
4"x4" TREATED WOOD CURB20" x 8" POURED CONCRETE FOOTING w/ 2) #5 BARS EACH WAY.SFTG. #1
6"x4" TREATED WOOD CURB20" x 8" POURED CONCRETE FOOTING w/ 2) #5 BARS EACH WAY.SFTG. #2
foundation PIER legend:
PIER #1 6x6 TRD. POST ON 12" BELL BOTTOM TO 18” @ 42" BELOW GRADE.DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:17 PM07 Foundation PlanPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05 1/4" = 1'-0"
1Foundation Plan
DIMENSIONS ARE FROM FACE OF CONCRETE TO FACE OF CONCRETE
ALL WALLS SHOWN ARE POURED CONCRETE. ALL WALLS, FOOTINGS, AND PADS TO HAVE REBAR AS SPECIFIED BY CODE AND A LICENSED STRUCTURAL ENGINEER.
GRAYED OUT FOUNDATION WALLS ARE PULLED INTO HOUSE 2” w/ A CANTILEVERED 2X8 SILL PLATE
REFER TO SILL PLATE AND FLOOR DETAILS LOCATED ON PAGE A08 AND STRUCTURAL DRAWINGS FOR ADDITIONAL DETAILS
foundation plan notes:
FOUNDATION WALL HEIGHTS ARE SUBJECT TO CHANGE DUE TO GRADE AND SITE CONDITIONS.
ALL FOUNDATION WALL HEIGHTS MUST BE VERIFIED ON SITE BY THE CONTRACTOR AND SITE SURVEYOR PRIOR TO CONSTRUCTION.
FOUNDATION CONTRACTOR WILL STEP FOUNDATION WALLS AS NECESSARY TO MAINTAIN PROPER FROST PROTECTION (42" BELOW GRADE) IN ACCORDANCE TO CURRENT MINNESOTA CODE, REGULATIONS, AND ZONING.
FOUNDATION WALLS DISCLOSURE:
DAVID CHARLEZ DESIGNS RECOMMENDS MASONRY CONCRETE LEDGES FOR ALL EXTERIOR MASONRY CLADDING PRODUCTS.
WHEN MASONRY CONCRETE LEDGES ARE NOT PROVIDED PER GENERAL CONTRACTOR’S REQUEST DAVID CHARLEZ DESIGNS DOES NOT ACCEPT RESPONSIBILITY FOR ANY EXTERIOR MASONRY CLADDING FAILURES.
MASONRY CLADDING CONCRETE LEDGES DISCLOSURE:REVISION SCHEDULENumberDate Issued by
Concrete Reinforcing Schedule
Wall Type
Wall Footing Size
NotesHeight Thickness.
Vertical
Reinf.
Horizontal
Reinf.Width Depth
Reinforcin
g
F1 9'-0" 8" #5 @ 24" #4 @ 48" 20" 8" 2) #5
F2 9'-0" 8" #5 @ 24" #4 @ 48" 20" 8" 2) #5
F3 9'-0" 10" #5 @ 24" #4 @ 48" 20" 8" 2) #5
F4 - N/A
F5 3'-6" 10" #4 @ 48" #4 @ 48" 20" 8" 2) #5
F6 3'-6" 12" #4 @ 48" #4 @ 48" 20" 8" 2) #5
F7 3'-6" 8" #4 @ 48" #4 @ 48" 20" 8" 2) #5
F8 3'-6" 10" #4 @ 48" #4 @ 48" 20" 8" 2) #5
F9 3'-6" 8" #4 @ 48" #4 @ 48" 20" 8" 2) #5
*** ALL BARS TO BE ON THE INSIDE
FACE, UNO
*** ALL WALLS TO HAVE WALL DOWELS
EMBEDDED IN FOOTING 7" MIN.
SPACED TO MATCH VERTICAL
REINFORCING SPACING
*** ALL CORNERS TO HAVE 24"x24"
L-BARS @ HORIZONTAL REINFORCING
SPACING
UFER Ground
-Provide 20' Rebar in footing and stub
up near electrical service panel.
PFTG #136”x36”x12” POURED CONCRETE PAD FOOTINGw/ 4) #5 BARS EACH WAY.
PFTG #1 36”x36”x12” POURED CONCRETE PAD FOOTINGw/ 4) #5 BARS EACH WAY.
PFTG #242”x4212” POURED CONCRETE PAD FOOTINGw/ 5) #5 BARS EACH WAY.
2" RIGID INSULATION
EXTERIOR CLADDING PER PLAN
1/2" SHEATHING 2X8 CANTILEVEREDSILL PLATE
1/2" ANCHOR BOLT
BUILDING PAPER
2"
FOUNDATION WALL PULLEDINTO HOUSE 2"
2X6 SOLE PLATE
2X8 SILL PLATE LOOKOUT WALL
NOTE:ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL. FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH GENERAL CONTRACTOR.
NOTE:
NOTE:FOUNDATION WALL SIZE MAY VARY PER LOCATION. SEE FOUNDATION PLAN
INSULATION PER CODE
2X6 STUDS @ 16" O.C.
1/2" GYP. BRD.
DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE.
NOTE:
6"4"
10"3 1/2"2" INSULATION2" INSULATION @ 45 DEGREE ANGLE
4" SAND
10" WALKOUT WALL
NOTE:ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL. FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH GENERAL CONTRACTOR.
NOTE:
EXTERIOR CLADDINGPER PLAN
BUILDING PAPER
1/2" PLYWOOD
2X6 STUDS @ 16" O.C.
INSULATION PER CODE
METAL FLASHING
1/2" GYP. BRD.
1/2" ANCHOR BOLT
2X6 SILL PLATE
DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE.
NOTE:
8"4"
12"3 1/2"2" INSULATION2" INSULATION @ 45 DEGREE ANGLE
4" SAND
12" walkout wall w/ 2x8 plate
NOTE:ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL. FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH GENERAL CONTRACTOR.
NOTE:
EXTERIOR CLADDINGPER PLAN
BUILDING PAPER
1/2" PLYWOOD
2X8 STUDS @ 16" O.C.
INSULATION PER CODE
METAL FLASHING
1/2" GYP. BRD.
1/2" ANCHOR BOLT
2X8 SILL PLATE
DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE.
NOTE:3 1/2"LAP SIDINGPER PLAN
BUILDING PAPER
1/2" PLYWOOD
2X6 STUDS @ 16" O.C.
INSULATION PER CODE(IF APPLICABLE)
METAL FLASHING
5/8" TYPE X.GYP. BRD.
1/2" ANCHOR BOLT
4" SAND BED
GARAGE SLAB CONSTRUCTION
NOTE:ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL. FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH GENERAL CONTRACTOR.
NOTE:
NOTE:FOUNDATION WALL SIZE MAY VARY PER LOCATION. SEE FOUNDATION PLAN
6"2"6"DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE.
NOTE:
GARAGE FLOOR:SLOPE GARAGE FLOOR TOWARDS OVERHEAD DOORS. SLOPE IN SLAB NOT SHOWN IN CROSS SECTIONS.
2" RIGID INSULATION
EXTERIOR CLADDING PER PLAN
1/2" SHEATHING
2X8 CANTILEVEREDSILL PLATE
1/2" ANCHOR BOLT
BUILDING PAPER
2"
FOUNDATION WALL PULLEDINTO HOUSE 2"
2x8 plate w/ bottom chord
NOTE:ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL. FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH GENERAL CONTRACTOR.
FLOOR TRUSSES PER PLAN
METAL FLASHING
NOTE:FOUNDATION WALL SIZE MAY VARY PER PROJECT. SEE FOUNDATION PLAN
2X6 SOLE PLATE
INSULATION PER CODE
2X6 STUDS @ 16" O.C.
1/2" GYP. BRD.
DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE.
NOTE:
2X6 SILL PLATE
1/2" ANCHOR BOLT6"2"6"2" RIGID INSULATION
5/8" TYPE XGYP. BRD.
FLOOR TRUSSES PER PLAN
2X6 SOLE PLATE
3-1/2" POUREDCONCRETE SLAB
NOTE:FOUNDATION WALL SIZE MAY VARY PER LOCATION. SEE FOUNDATION PLAN
BOTTOM CRD TRUSS @ GARAGE
NOTE:ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL. FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH GENERAL CONTRACTOR.
NOTE:3 1/2"1/2" GYP. BRD.
2X6 STUDS @ 16" O.C.
INSULATION PER CODE
DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE.
NOTE:
GARAGE FLOOR:
SLOPE GARAGE FLOOR TOWARDS OVERHEAD DOORS. SLOPE IN SLAB NOT SHOWN IN CROSS SECTIONS.
REINFORCING PER PLAN w/#5 L-BARS @ 24" O.C.
36
36
2" RIGID INSULATION
1/2" ANCHOR BOLT
SLAB @ BOTTOM CHORD TRUSS
SPECIAL FOUNDATION:ALL NON-STRUCTURAL EXTERIOR FOUNDATION WALLS NOT MORE THAN 2 STORIES HIGH WITH A GABLE ROOF (HIP ROOFS EXEMPT) ARE PULLED INTO THE HOUSE 1-1/2"
NOTE:
DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT TO CHANGE. ALL FOUNDATION WALLS (STRUCTURAL AND NON-STRUCURAL) MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR FOUNDATION WALLS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE.
FLOOR TRUSSESPER PLAN
4"6"
10"
4" CONC. FLOOR
2X8 SILL PLATE
NOTE:FOUNDATION WALL SIZE MAY VARY PER LOCATION. SEE FOUNDATION PLAN
EXTERIOR CLADDING PER PLAN
1/2" SHEATHING
BUILDING PAPER
2X6 SOLE PLATE
INSULATION PER CODE
2X6 STUDS @ 16" O.C.
1/2" GYP. BRD.
METAL FLASHING
2"
2"6" 2"3 1/2"4" SAND
10" garage slab w/ 2" ledge
NOTE:ALL APPLICABLE AREAS ON THIS PLAN TO BE BUILT ACCORDING TO THIS DETAIL. FOR AREAS THAT DO NOT APPLY TO THIS DETAIL, REFERENCE ANOTHER DETAIL PROVIDED ON PLANS OR CONSULT WITH GENERAL CONTRACTOR FOR PERFERRED CONSTRUCTION METHODS. ALL DETAILS TO BE VERIFED AND CONFIRMED WITH GENERAL CONTRACTOR.
NOTE:
1/2" PLYWOOD
2X6 STUDS @ 16" O.C.
INSULATION PER CODE
METAL FLASHING
1/2" GYP. BRD.
1/2" ANCHOR BOLT
2X6 SILL PLATE
DRAWINGS HAVE NOT BEEN DRAWN OR APPROVED BY A STRUCURAL ENGINEER. SUBJECT TO CHANGE. ALL ITEMS SHOWN MUST BE VERIFIED WITH STRUCTURAL ENGINEER FOR SAFETY AND CODE COMPLIANCE BEFORE, DURING, AND AFTER CONSTRUCTION. DAVID CHARLEZ DESIGNS DOES NOT ACCEPT ANY RESPONSIBILITY FOR ANY STRUCTURAL MEMBERS NOT PROPERLY ENGINEERED AS REQUIRED FOR STRUCTURE.
NOTE:
10"
2" STONE VENEER w/ GROUTED JOINTS
WOW-3639 SPACED 10" ON CENTER
EMC-3639 DRAINAGE FABRIC
2)LAYERS GRADE "D" CONSTRUCTION PAPER OR CODE REQUIRED WRB
HEAVY MOISTURE RESISTANT COATING
STRUCTURAL NOTESUNLESS NOTED OTHERWISE ON THE PLANS AND/OR IN THE DETAILS, THESE NOTES SHALL APPLY. IF THERE ARE DISCREPANCIES BETWEEN THE PLANS, DETAILS, SPECIFICATIONS, AND THESE NOTES, THE CONTRACTOR SHALL CONFORM TO THE MORE STRINGENT REQUIREMENTS, UNLESS CLARIFIED WITH THE STRUCTURAL ENGINEER OF RECORD (SER) PRIOR TO WORK.
MATERIAL STRENGTHS
STRUCTURAL STEELHSS RECTANGULAR AND SQUARE - ASTM A500 GR. C, FY = 50 KSIW AND WT SHAPES - ASTM A992, FY = 50 KSIMISC. STRUCTURAL STEEL - ASTM A36, FY = 36 KSI
STRUCTURAL STEEL FASTENERSCONNECTION BOLTS - ASTM A325 OR F1852, FU = 120 KSIANCHOR RODS - ASTM F1554, GR. 36, FY = 36 KSITHREADED RODS - ASTM A36, FY = 36 KSI
REINFORCING STEELDEFORMED BARS - ASTM A615, GR. 60, FY = 60 KSIFABRIC - ASTM A185, FY = 70 KSI
CONCRETEF 'C = COMPRESSIVE STRENGTH IN 28 DAYS4,000 PSI UNLESS NOTED OTHERWISE5,000 PSI FOR FOOTINGS
STRUCTURAL LUMBERALL DIMENSIONAL LUMBER - #2 SPRUCE PINE FIR (SPF) OR EQUALLAMINATED VENEER LUMBER (LVL)E = 2,000,000 PSIFB = 2600 PSILAMINATED STRAND LUMBER (LSL)E = 1,550,000 PSIFB = 2,325 PSIPARALLEL STRAND LUMBER (PSL)E = 2,000,000 PSIFB = 2900 PSITREATED LUMBER - #2 SOUTHERN PINE OR EQUAL
DESIGN LOADS
ROOFDEAD LOAD17 PSF (7 PSF TOP CHORD + 10 PSF BOTTOM CHORD)SNOW LOADROOF SNOW LOAD = 42 PSFFLOORSDEAD LOAD20 PSF (10 PSF TOP CHORD + 10 PSF BOTTOM CHORD)LIVE LOADS40 PSFWINDULTIMATE DESIGN WIND SPEED 115 MPH3 SECOND GUST.EXPOSURE C, I = 1.0RISK CATEGORY II
EXISTING CONDITIONS
CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND DETAILS OF EXISTING STRUCTURE WHERE THEY AFFECT THIS CONSTRUCTION PRIOR TO FABRICATION. CONTRACTOR SHALL TAKE PRECAUTIONS TO AVOID ADDING LOAD OR STRESS TO ANY ADJACENT STRUCTURES DURING CONSTRUCTION.
TEMPORARY BRACING
CONTRACTOR IS RESPONSIBLE FOR BRACING, WITHOUT OVERSTRESSING, ALL STRUCTURAL ELEMENTS AS REQUIRED AT ALL STAGES OF CONSTRUCTION UNTIL COMPLETION OF THIS PROJECT. PROVIDE TEMPORARY LATERAL SUPPORT FOR ALL WALLS UNTIL WALLS ARE ADEQUATELY BRACED BY PERMANENT STRUCTURE. SHORE FOUNDATION WALLS RETAINING EARTH UNTIL FLOOR FRAMING AND BASEMENT SLAB ARE IN PLACE. USE CAUTION WHEN OPERATING EQUIPMENT ADJACENT TO FOUNDATION WALLS.
GENERAL SOIL NOTES
THE STRUCTURE HAS BEEN DESIGNED USING A PRESUMPTIVE LOAD-BEARING VALUE OF 2000 PSF IN ACCORDANCE WITH TABLE R401.4.1 OF THE 2012 IRC ON VIRGIN SOIL OR COMPACTED GRANULAR FILL FOR FOOTINGS. PRESUMPTIVE SOIL BEARING VALUE TO BE VERIFIED BY A GEOTECHNICAL ENGINEER WHERE REQUIRED BY THE BUILDING OFFICIAL PER R401.4.ANY DISCREPANCIES IN THE ASSUMED ALLOWABLE SOIL BEARING PRESSURE SHALL BE REPORTED IMMEDIATELY.THE EXISTING FOOTINGS HAVE BEEN ASSUMED TO BE TYPICAL SPREAD FOOTINGS ON GOOD SOILS THAT ARE ASSUMED TO BE PERFORMING ADEQUATELY.REMOVE ALL TOP SOIL, UNCOMPACTED FILL, OR OTHER POOR SOIL FROM THE CONSTRUCTION AREA.SLOPE THE SITE TO DRAIN AWAY FROM THE BUILDING.INSTALL GUTTERS AND DOWNSPOUTS WITH LONG EXTENSIONS RECOMMENDED.INSTALL DRAIN TILE RECOMMENDED.BACKFILL WITH GRANULAR SOILS RECOMMENDED.
FOOTINGS/FOUNDATIONS
ALL FOOTINGS ARE TO BE FORMED. ALL STUMPS, ROOTS AND DEBRIS MUST BE REMOVED FROM THE SOIL TO A DEPTH OF AT LEAST 12" BELOW THE SURFACE OF THE GROUND IN THE AREA OCCUPIED BY THE BUILDING. FOOTINGS SHALL BE PLACED ON VIRGIN SOIL OR COMPACTED GRANULAR FILL.WALL FOOTINGS ARE CAST-IN-PLACE CONCRETE WITH CONTINUOUS REINFORCING PLACED 3" CLEAR OF BOTTOM AND 2" CLEAR AT TOP AND SIDES.WALL FOOTINGS ARE CENTERED UNDER WALLS AND COLUMN FOOTINGS UNDER COLUMNS.WALL FOOTINGS SHALL BE A MINIMUM OF 8" THICK WITH A 4" PROJECTION EACH SIDE OF WALL. REINFORCE WITH 2 - #4 CONTINUOUS BOTTOM BARS.COLUMN FOOTINGS SHALL BE A MINIMUM OF 10" THICK, WITH PLAN DIMENSIONS AS SHOWN ON DRAWING. REINFORCE WITH #4 BOTTOM BARS AT 8" O.C. EACH WAY.PROVIDE 30 BAR DIAMETER LAP AT SPLICES AND FULL CROSSING LAP AT CORNERS AND INTERSECTIONS. TIE ALL REINFORCING IN PLACE. SET FOOTING REINFORCING ON CHAIRS OR MASONRY BRICK TO OBTAIN 3" CLEARANCE FROM BOTTOM OF FOOTING.MAINTAIN MINIMUM FROST DEPTH OF 42" FOR ALL EXTERIOR FOOTINGS.TOP OF FOOTING SHALL BE PLACED 8" BELOW THE TOP OF SLABS ON GRADE, OR PLACED TO MAINTAIN FROST DEPTH, WHICHEVER IS DEEPER.STEP FOOTINGS IN A UNIFORM MANNER USING A 2:1 HORIZONTAL TO VERTICAL SLOPE.CAST DOWELS IN FOOTING FOR FOUNDATION WALLS ABOVE. DOWELS SHALL BE THE SAME QUANTITY, SIZE, AND SPACING AS THE VERTICAL WALL REINFORCING.DOWELS SHALL BE 30" LONG AND EXTEND TO 3" CLEAR OF BOTTOM OF FOOTING.CONTRACTOR SHALL BE RESPONSIBLE FOR IMPLEMENTING HOT WEATHER CONCRETE REQUIREMENTS PER ACI 305 AND COLD WEATHER CONCRETE REQUIREMENTS PER ACI 306.SHORE ALL FOUNDATION WALLS APPROPRIATELY BEFORE BACKFILLING AND COMPACTING.FOUNDATIONS SUPPORTING WOOD SHALL EXTEND AT LEAST 6" ABOVE THE ADJACENT FINISHED GRADE.THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES AND TANKS PRIOR TO BEGINNING EXCAVATION.THE CONTRACTOR SHALL FOLLOW IRC FIGURE R403.1.7.1 FOR FOUNDATION CLEARANCES TO SLOPES UNLESS INDICATED OTHERWISE BY THE SOILS ENGINEER.
CONCRETE
PROVIDE READY-MIXED CONCRETE PER ASTM C94. PORTLAND CEMENT SHALL BE ASTM C150, TYPE I. USE ONLY ONE BRAND OF CEMENT THROUGHOUT THE WORK. PROVIDE CONCRETE AGGREGATES MEETING THE REQUIREMENTS OF ASTM C33.MAXIMUM AGGREGATE SIZE SHALL BE 3/4" FOR GRADE BEAMS AND SLABS. WATER SHALL BE CLEAN, FREE OF DELETERIOUS AMOUNTS OF ACIDS, ALKALIS, OR ORGANIC MATERIALS, AND SHALL BE CONSIDERED POTABLE. PROVIDE ADMIXTURES TO REDUCE WATER CONTENT, PROVIDE AIR-ENTRAINMENT, OR ALTER THE QUALITY OF THE CONCRETE TO MEET THE JOB CONDITIONS.PLACE REINFORCING 2" CLEAR TO OUTSIDE FACE AND 1 1/2" CLEAR TO INSIDE FACE OF CONCRETE WALL.PROVIDE #4 X 4'-0" LONG (EQUAL LEGS) HORIZONTAL REINFORCING CORNER BARS AT 18" O.C. AT OUTSIDE CORNER OF WALL AND 2 - #4 VERTICAL SUPPORT BARS.ALL WALL OPENINGS LARGER THAN 12" SHALL HAVE 2 - #5 AT ALL SIDES EXTENDING 2'-0" BEYOND EACH EDGE OF OPENING WITH 2 - #5 X 4'-0" DIAGONAL BARS AT EACH CORNER OF OPENING.WALL REINFORCING SHALL BE CONTINUOUS THROUGH COLUMNS AND PILASTERS.PROVIDE FULL DEVELOPMENT AND SPLICE LENGTHS PER CONCRETE REINFORCING STEEL INSTITUTE (CRSI) OR ACI 318 REQUIREMENTS.ALL CONCRETE EXPOSED TO WEATHER, FREEZE-THAW CONDITIONS OR DE-ICING CHEMICALS SHALL CONTAIN 5% - 7% ENTRAINED AIR.SLUMP SHALL BE DETERMINED BY ASTM C143 AS FOLLOWS:FOOTINGS 3" - 4"WALLS, COLUMNS 3" - 5"SLABS ON GRADE 3" - 4"STRUCTURAL SLABS, BEAMS 3" - 4"CONCRETE SHALL NOT BE LAID WHEN THE TEMPERATURE OF THE OUTSIDE AIR IS BELOW 40 DEGREES FAHRENHEIT, UNLESS APPROVED METHODS ARE USED DURING CONSTRUCTION TO PREVENT DAMAGE TO THE CONCRETE. ALL MATERIALS USED AND SURFACES BUILT UPON SHALL BE FREE OF SNOW AND ICE.WOOD BEAMS POCKETED INTO CONCRETE SHALL BE PROVIDED WITH A 1/2" AIR SPACE ON TOP, END, AND SIDES UNLESS TREATED WOOD OR STEEL PLATES ARE USED.CONCRETE SHALL NOT BEAR PERMANENTLY ON WOOD MEMBERS.
SLABS ON GRADE
ALL SLABS ON GRADE SHALL BE REINFORCED WITH EITHER WWF6X6-W1.4 X W1.4 IN CENTER OF SLAB.SLABS ON GRADE ADJACENT TO FOUNDATION WALLS RETAINING EARTH SHALL BE A MINIMUM OF 3 1/2" THICK.CONSTRUCTION AND/OR CONTROL JOINTS SHALL OCCUR AT A MAXIMUM OF 8'-0" O.C. AT EXTERIOR SLABS ON GRADE, AND AT A MAXIMUM OF 10'-0" O.C. AT INTERIOR SLABS ON GRADE.CONSTRUCTION AND/OR CONTROL JOINTS SHALL BE LAID OUT IN A RECTANGULAR PATTERN WITH LONG TO SHORT SIDE RATIO LESS THAN OR EQUAL TO 1.5 AND WITH NO RE-ENTRANT CORNERS.CONTROL JOINTS FOR SLABS ON GRADE SHALL BE SAW CUT AS SOON AS CONCRETE CAN ACCEPT IT WITHOUT RAVELING. DO NOT CUT STRUCTURAL SLABS OR TOPPING SLABS.ALL CONTROL/CONSTRUCTION JOINTS SHALL BE CONTINUOUS AND NOT STAGGERED OR OFFSET.CONTROL JOINTS SHALL BE CLEANED AND SEALED FOR CURING PURPOSES AS SOON AS POSSIBLE.VERIFY FLOOR FINISHES AND CONTROL/CONSTRUCTION JOINT LOCATIONS WITH OWNER AND ARCHITECT.
STRUCTURAL STEEL
ALL STRUCTURAL STEEL SHALL BE DESIGNED, FABRICATED, AND ERECTED ACCORDING TO THE SPECIFICATIONS OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION(A.I.S.C.) LATEST ADOPTION.STRUCTURAL STEEL SUPPLIER SHALL SUPPLY ALL CAP PLATES, BEARING ASSEMBLIES, BASE PLATES, STIFFENERS, SPLICES, AND CONNECTIONS, AND SHALL FOLLOW STANDARD AISC DETAILS UNLESS NOTED ON DRAWINGS.ALL WELDING SHALL BE DONE BY THE SHIELDED ARC PROCESS USING E70 ELECTRODES IN ACCORDANCE WITH THE RULES OF THE AMERICAN WELDING SOCIETY (A.W.S.) STRUCTURAL WELDING CODE, LATEST ADOPTION. ALL WELDERS SHALL BE CERTIFIED BY THE RULES OF THE AMERICAN WELDING SOCIETY.TIGHTEN ANCHOR BOLTS AND GROUT COLUMN BASE PLATES BEFORE INSTALLING STEEL BEAMS.PROVIDE COMPLETE DETAILED SHOP DRAWINGS TO THE CONTRACTOR FOR REVIEW AND APPROVAL PRIOR TO FABRICATION.PROVIDE 5/16” FULL HEIGHT WEB STIFFENERS AT ALL COLUMN AND SUPPORT LOCATIONS.DESIGN INTENTION WHEN COLUMNS BEAR ON BEAMS IS TO HAVE BEARING PLATES MATCH BEAM WIDTH X COLUMN WIDTH + 6”.
DIMENSION LUMBER
DESIGN ASSUMES LUMBER IS FREE OF SIGNIFICANT SPLITS AND CHECKS, AND CONTRACTOR WILL VISUALLY INSPECT DURING INSTALLATION.SILLS AND ALL OTHER LUMBER IN CONTACT WITH CONCRETE OR MASONRY AND WITHIN 8" OF FINISHED GRADE SHALL BE PRESERVATIVE TREATED WOOD. IN CRAWLSPACES OR UNEXCAVATED AREAS WITHIN THE BUILDING FOUNDATION, WOOD SHALL BE PRESERVATIVE TREATED FOR JOISTS WITHIN 18" OF EXPOSED GROUND AND/OR GIRDERS WITHIN 12" OF EXPOSED GROUND.PRESERVATIVE TREATED WOOD SHALL BE IN ACCORDANCE WITH THE AMERICAN WOOD PROTECTION ASSOCIATION, STANDARD U1.TREAT ALL CUT ENDS OF TREATED MATERIAL.ALL LUMBER IS TO BE GRADE STAMPED, WHICH IS TO CONTAIN GRADING AGENCY, MILL NUMBER OR NAME, GRADE OF LUMBER, SPECIES OR SPECIES GROUPING OR COMBINATION DESIGNATION, RULES UNDER WHICH GRADED, WHERE APPLICABLE, AND CONDITION OF SEASONING AT TIME OF MANUFACTURE.ALL LUMBER SHALL BE SEASONED TO A MOISTURE CONTENT OF 19% OR LESS, WITH THE INDICATION OF "S-DRY" ON THE GRADE STAMP.ALL LUMBER SHALL BE PROTECTED FROM THE ELEMENTS.SILL PLATES TO BE BOLTED TO FOUNDATION WALL WITH 1/2" DIAMETER GALV ANCHOR BOLTS AT 3'-0" O.C. MAXIMUM. BOLTS TO EXTEND 9" MINIMUM INTO SOLIDLY GROUTED FOUNDATION WALL. EACH SILL PLATE TO HAVE A MINIMUM OF 2 BOLTS WITH ONE BOLT LOCATED NOT MORE THAN 12 INCHES OR LESS THAN 4 1/2 INCHES FROM EACH END OF THE PLATE SECTION. USE 1/8" X 2" GALV WASHERS, SLIGHTLY CRUSHING PLATE.MINIMUM NAILING SHALL BE IN ACCORDANCE WITH TABLE R602.3(1) OF THE 2012 IRC UNLESS NOTED OTHERWISE.ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND DOUBLE TOP PLATE.EXTERIOR WALLS SHALL BE 2 X 6 STUDS @ 16" O.C. UNLESS NOTED OTHERWISE.INTERIOR BEARING WALLS SHALL BE 2 X 6 STUDS @ 16" O.C. UNLESS NOTED OTHERWISE.INTERIOR NON-LOAD-BEARING WALLS SHALL BE 2 X 4 STUDS @ 16" O.C. UNLESS NOTED.TYPICAL OPENINGS TO HAVE A MINIMUM OF 2 BEARING (TRIMMER OR JACK) STUDS AND 1 FULL-HEIGHT KING STUD.HEADERS NOT NOTED TO BE 2 - 2 X 6 UP TO 4'-0" SPAN AND 2 - 2 X 8 FROM 4'-0" TO 6'-0" SPAN.WOOD HEADERS SHALL HAVE A MINIMUM 3" LENGTH OF BEARING AT EACH END OR BEAR THE ENTIRE LENGTH OF THE BEARING STUDS.BEAMS SHALL BEAR ON A MINIMUM OF 3" ALONG THEIR LENGTH AND FULLY ALONG THEIR WIDTH AND HAVE A MINIMUM OF 2 TYPICAL WALL STUDS SUPPORTING THEM.JOISTS SHALL BEAR THE FULL WIDTH OF SUPPORTING MEMBERS (STUD WALL, BEAMS, ETC.).PROVIDE SOLID VERTICAL BLOCKING AT ALL JOIST SPACES BELOW WOOD COLUMNS. PROVIDE MATCHING COLUMNS TO FOUNDATION AT LOWER LEVELS BELOW COLUMNS COMPRISED OF 3 OR MORE STUDS.ALL BEAMS AND JOISTS NOT BEARING ON SUPPORTING MEMBERS SHALL BE FRAMED WITH PREFABRICATED JOIST HANGERS.BEAMS OR HEADERS MADE OF 2 - 2X'S WITH 1/2" SPACER SHALL BE NAILED TOGETHER WITH 2 - ROWS 16D NAILS (.162" X 3 ½") AT 12" O.C. ALONG EACH EDGE, TYPICAL FOR EACH LUMBER PLY.NAIL BUILT UP POSTS MADE OF 2X STUD MATERIAL WITH 2 - ROWS 16D NAILS 12” OC EACH PLY, UP TO 3-PLIES. SCREW BUILT UP POSTS MADE OF 2X STUD MATERIAL WITH ¼”X6” SDS SCREWS 8” OC STAGGERED FOR 4-PLIES.ATTACH 4-PLY LVL BEAMS WITH 2-ROWS OF ¼”X6” SDS SCREWS 24” OC BOTH FACES UNLESS NOTED.SPACING OF BRIDGING FOR JOISTS SHALL NOT EXCEED 8'-0".DOUBLE ALL JOISTS UNDER PARALLEL PARTITIONS OR SINGLE FLOOR TRUSS.ALL PLYWOOD AND OSB SHALL BE INSTALLED PER AMERICAN PLYWOOD ASSOCIATION STANDARDS, INCLUDING THE USE OF CONSTRUCTION ADHESIVE FOR FASTENING TO FLOOR JOISTS.ALL FASTENERS AND HANGERS IN CONTACT WITH TREATED LUMBER SHALL BE G185 HOT DIPPED GALVANIZED OR EQUAL.LUMBER GRADING RULES AND WOOD SPECIES SHALL CONFORM TO VOLUNTARY PRODUCT STANDARD PS 20-99 AS PUBLISHED BY THE DEPARTMENT OF COMMERCE. GRADING RULES SHALL BE BY AN AGENCY CERTIFIED BY THE BOARD OF REVIEW OF THE AMERICAN LUMBER STANDARDS COMMITTEE.PERFORMANCE REQUIREMENTS, ADHESIVE BOND PERFORMANCE, PANEL CONSTRUCTION AND WORKMANSHIP, DIMENSIONS AND TOLERANCES, MARKING, AND MOISTURE CONTENT OF WOOD-BASED STRUCTURAL-USE PANELS SHALL CONFORM TO VOLUNTARY PRODUCT STANDARD PS 2-92, AS PUBLISHED BY THE DEPARTMENT OF COMMERCE.PLACE SHEETROCK WALL CONTROL JOINTS MAX 30FT APART PER THE WALL AND CEILING BUREAU TECHNICAL BULLETIN.DO NOT DRILL OR NOTCH PLUMBING HOLES NEAR KNOTS IN ANY FRAMING.
WOOD TRUSSES
RESPONSIBILITIES OF THE CONTRACTOR, BUILDING DESIGNER, TRUSS MANUFACTURER, AND TRUSS DESIGNER SHALL FOLLOW THE PUBLICATION "TPI 1-2002 NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION."TRUSS SUPPLIER SHALL NOTIFY SER OF ANY PROPOSED REVISIONS TO THE LAYOUT INDICATED ON THIS PLAN. REVISIONS THAT AFFECT THE STRUCTURAL DESIGN WILL NOT BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL BY THE SER.VERIFY ALLOWABLE BEARING LOCATIONS FOR GIRDER TRUSSES WITH SER PRIOR TO FINAL DESIGN STAGE. PROVIDE METAL BEARING ENHANCERS AS NECESSARY TO UTILIZE STUD COLUMNS SHOWN ON PLAN.ALL PREFABRICATED WOOD TRUSSES SHALL BE FURNISHED IN ACCORDANCE WITH DESIGNS PREPARED USING THE DESIGN LOADS AND SPAN CONDITIONS INDICATED, INCLUDING DESIGNING GABLE END TRUSS WEBS FOR PERPENDICULAR TO FACE WIND LOADS.TRUSS MANUFACTURER SHALL PROVIDE A TRUSS DRAWING PRIOR TO BEGINNING CONSTRUCTION.TRUSSES SHALL BE DESIGNED FOR TOP AND BOTTOM CHORD SUPERIMPOSED DEAD AND LIVE LOADS AS INDICATED ABOVE.TRUSS SUPPLIER SHALL DESIGN TRUSSES TO SUPPORT ADDITIONAL DEAD LOAD FROM, BUT NOT LIMITED TO, SPRINKLER LINES, AND RAIN LEADER SYSTEMS, PIPING, CABLE TRAYS, DUCTWORK, ETC., AS PER IBC. COORDINATE WITH MECHANICAL/ELECTRICAL AS REQUIRED. GENERAL CONTRACTOR TO VERIFY LOCATION AND MAGNITUDE OF ALL SUCH LOADS WITH TRUSS SUPPLIER AND SER PRIOR TO FABRICATION OF TRUSSES.SEE ARCHITECTURAL PLANS FOR ATTIC DRAFT STOP LOCATIONS AND DESIGN ROOF TRUSSES ACCORDINGLY.LIVE LOAD DEFLECTION OF ROOF TRUSSES SHALL BE LIMITED TO 1/480 OF THE SPAN.DESIGN TRUSSES FOR TOP CHORD BEARING OR BOTTOM CHORD BEARING AS SHOWN ON DRAWINGS.TRUSS CONFIGURATION, PITCH, OVERHANG, ETC. SHALL BE INDICATED ON THE ARCHITECTURAL DRAWINGS.SPACING OF ROOF TRUSSES SHALL NOT EXCEED 24" O.C.LUMBER FOR WOOD TRUSSES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.TRUSS MANUFACTURER TO PROVIDE GIRDER TRUSSES, HIP JACKS, AND STEP-DOWN TRUSSES AS REQUIRED AND DESIGNED TO SUPPORT ALL SUPERIMPOSED LOADS.PROVIDE HIP-SETS, DORMERS, AND PIGGY-BACK TRUSSES AS REQUIRED.TRUSS MANUFACTURER TO SPECIFY IF ROOF SHEATHING NEEDS TO BE APPLIED BEFORE PLACING "OVER-FRAMING".PROVIDE METAL FRAMING ANCHORS AT TRUSS BEARING TO MECHANICALLY FASTEN TRUSS TO BEARING WALL OR SUPPORTING MEMBER AS SHOWN IN DETAILS.TRUSS MANUFACTURER SHALL PROVIDE TRUSS TO TRUSS CONNECTION HANGERS.BRIDGING, AND BRACING OF TRUSS COMPRESSION AND TENSION MEMBERS, SHALL BE INSTALLED IN ACCORDANCE WITH THE TRUSS MANUFACTURER'S DESIGN AND DIRECTIONS.NO CUTTING, NOTCHING, OR MODIFICATIONS OF TRUSSES WILL BE ALLOWED WITHOUT THE MANUFACTURER'S WRITTEN APPROVAL.CONTRACTOR SHALL PROVIDE PERMANENT AND TEMPORARY DIAGONAL, LATERAL, AND CROSS BRACING IN ACCORDANCE WITH THE PUBLICATION "BCSI 1-03 BUILDING COMPONENT SAFETY INFORMATION, GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING AND BRACING OF METAL PLATE CONNECTED WOOD TRUSSES" BY THE TRUSS PLATE INSTITUTE AND WOOD TRUSS COUNCIL OF AMERICA AND AS OTHERWISE NECESSARY. FOR SPANS LONGER THAN 60FT., CONTRACTOR SHALL HIRE A STRUCTURAL ENGINEER TO DESIGN THE NECESSARY BRACING.PERMANENT BOTTOM CHORD BRACING AND WEB BRACING SHALL BE LOCATED AS SHOWN ON THE TRUSS DRAWINGS AND SHALL BE MINIMUM 2 X 4 WITH 2 - 16D NAILS TO END WALLS AND TRUSSES, LAPPING TWO TRUSS SPACES AT SPLICES.
TRUS JOIST (TJI)
ALL SPECIFIED ENGINEERED WOOD PRODUCTS SHALL BE MANUFACTURED AND LABELED AS TRUS JOIST PRODUCTS BY WEYERHAEUSER. ICC-ES CODE EVALUATION REPORTS SHALL BE THE FOLLOWING:ESR-1153 FOR TJI® JOISTSESR-1387 FOR TIMBERSTRAND® LSL, MICROLLAM® LVL & PARALLAM® PSLMODIFICATIONS/ALTERNATES: THE SPECIFICATION IS BASED ON TRUS JOIST ENGINEERED WOOD PRODUCTS. NO ALTERNATIVES, MODIFICATIONS OR SUBSTITUTIONS ARE ALLOWED UNLESS THE GENERAL CONTRACTOR AND SUB-CONTRACTORS SUBMITS IN WRITING FOR SUCH REQUESTS TO THE PROJECT ENGINEER FOR APPROVAL, NO LATER THAN TWO WEEKS PRIOR TO BID. ALTERNATE PRODUCTS MUST HAVE A CURRENT ICC-ES CODE EVALUATION REPORT WITH LISTED DESIGN PROPERTIES EQUIVALENT OR GREATER THAN SPECIFIED PRODUCTS. SUBSTANTIATING CALCULATIONS SHALL BE SUBMITTED. ALL HOLES, TAPERED CUTS AND NOTCHING SHALL BE JUSTIFIED FOR ALTERNATE. CONTRACT SHALL REFLECT ANY PRICE CHANGES. THE ENGINEER OF RECORD SHALL BE REIMBURSED FOR ANY REVIEW TIME.ALL I JOISTS SHALL BE MANUFACTURED WITH LVL FLANGE MATERIAL. WEB MATERIAL SHALL BE EQUIVALENT TO PERFORMANCE PLUS® OSB. DIAPHRAGM CAPACITY AND NAILING LIMITATIONS OF ALTERNATE SHALL BE SUBSTANTIATED AS EQUIVALENT IN AN ICC-ES CODE EVALUATION REPORT.WHEN APPLICABLE, FLOOR PERFORMANCE OF ALTERNATE SHALL BE SUBSTANTIATED AS EQUIVALENT TO: TJ-PRO RATING OF 40.ALL TIMBERSTRAND® LSL RIM BOARD/BLOCKING SUBSTITUTIONS SHALL BE ICC-ES REPORT EVALUATED FOR USE AS RIM BOARD/BLOCKING AND/OR BE CROSS-PLY LAMINATED.ALL EQUIVALENT FIRE AND SOUND RATINGS FOR FLOOR/CEILING ASSEMBLIES SHALL BE SUBSTANTIATED IN AN ICC-ES CODE EVALUATION REPORT OR SIMILAR THIRD PARTY EVALUATION AS EQUIVALENT TO TJI JOIST ASSEMBLIES.
WALL SHEATHING
WALL SHEATHING SHALL BE MINIMUM 15/32" THICK APA RATED PANELS, RATED FOR SPACING OF SUPPORTING MEMBERS. A MINIMUM 32/16 SPAN RATING IS RECOMMENDED. BLOCK ALL JOINTS.PROVIDE EXTERIOR OR EXPOSURE 1 GRADE. PANELS SHALL BE CONTINUOUS OVER TWO OR MORE SPANS, AND LONG DIMENSION OF PANEL SHALL BE EITHER PERPENDICULAR OR PARALLEL TO SUPPORTS. FASTEN WALL SHEATHING WITH 8D NAILS SPACED AT 4" O.C. AT SUPPORTED EDGES AND 8" O.C. AT INTERMEDIATE SUPPORTS. LEAVE AN 1/8" GAP AT ALL END AND EDGE JOINTS TO ALLOW FOR EXPANSION. STAGGER END JOINTS OF PANELS. REFER TO PLAN AND NOTES FOR ANY SPECIAL SHEAR WALL NAILING AND BOLTING CONDITIONS. GYPSUM SHEATHING TO BE A MINIMUM OF 1/2" THICK FASTENED WITH 6D COOLER OR WALLBOARD NAILS AT 7" O.C. TO ALL FRAMING MEMBERS UNLESS NOTED OTHERWISE.
ROOF SHEATHING
ROOF SHEATHING SHALL BE MINIMUM 15/32" THICK APA RATED PANELS, RATED FOR SPACING OF SUPPORTING MEMBERS. A MINIMUM OF 40/20 SPAN RATING IS RECOMMENDED. PROVIDE PANEL CLIPS, ONE BETWEEN EACH SUPPORT, FOR SUPPORTS SPACED GREATER THAN 16" O.C.PROVIDE EXTERIOR OR EXPOSURE 1 GRADE. PANELS SHALL BE CONTINUOUS OVER TWO OR MORE SPANS, AND LONG DIMENSION OF PANEL SHALL BE PERPENDICULAR TO SUPPORTS. FASTEN ROOF SHEATHING WITH 8D NAILS SPACED AT 4" O.C. AT SUPPORTED EDGES AND 8" O.C. AT INTERMEDIATE SUPPORTS.LEAVE AN 1/8" GAP AT ALL END AND EDGE JOINTS TO ALLOW FOR EXPANSION. DESIGN OF ROOF SHEATHING ASSUMES THAT THE ROOF WILL BE PROPERLY INSULATED AND VENTILATED. REFER TO APA PUBLICATION N335N "PROPER INSTALLATION OF APA RATED SHEATHING FOR ROOF APPLICATIONS."
FLOOR SHEATHING
FLOOR SHEATHING SHALL BE MINIMUM 23/32" THICK TONGUE AND GROOVE APA RATED PANELS, RATED FOR SPACING OF SUPPORTING MEMBERS. A MINIMUM OF 48/24 SPAN RATING IS RECOMMENDED. PROVIDE EXPOSURE 1 GRADE. PANELS SHALL BE CONTINUOUS OVER TWO OR MORE SPANS, AND LONG DIMENSION OF PANEL SHALL BE PERPENDICULAR TO SUPPORTS. FASTEN SHEATHING WITH CONSTRUCTION ADHESIVE AND 8D NAILS SPACED AT 4" O.C. AT SUPPORTED EDGES AND 8" O.C. AT INTERMEDIATE SUPPORTS.
LVL WOOD MEMBERS
LVL MEMBERS NOTED ON DRAWINGS ARE ENGINEERED LAMINATED VENEER LUMBER AS MANUFACTURED BY THE WEYERHAEUSER COMPANY. ALTERNATE AT CONTRACTOR'S OPTION OF EQUAL DESIGN PROPERTIES.SIZES SHOWN ON PLAN ARE ACTUAL SIZE.
PSL WOOD MEMBERS
PSL MEMBERS NOTED ON DRAWINGS ARE ENGINEERED PARALLEL STRAND LUMBER AS MANUFACTURED BY THE WEYERHAEUSER COMPANY. ALTERNATE AT CONTRACTOR'S OPTION OF EQUAL DESIGN PROPERTIES.SIZES SHOWN ON PLAN ARE ACTUAL SIZE.
LSL WOOD MEMBERS
LSL MEMBERS NOTED ON DRAWINGS ARE ENGINEERED LAMINATED STRAND LUMBER AS MANUFACTURED BY THE WEYERHAEUSER COMPANY. ALTERNATE AT CONTRACTOR'S OPTION OF EQUAL DESIGN PROPERTIES.SIZES SHOWN ON PLAN ARE ACTUAL SIZE.
ADHESIVE/EXPANSION ANCHORSADHESIVE AND EXPANSION ANCHORS SHALL BE PROVIDED AND INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ADHESIVE ANCHORING SYSTEM TO BE HILTI HIT RE 500 ADHESIVE. CONCRETE SCREWS SHALL BE HILTI KWIK HUS-EZ. ALTERNATE ANCHORING SYSTEM MAY BE SUBMITTED FOR APPROVAL. "FAST SET EPOXY" IS NOT PERMITTED. REFERENCE DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:19 PM08 Foundation DetailsPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05REVISION SCHEDULENumberDate Issued by
UP
UP
SUMP w/SEALEDCOVER 16' - 0"28' - 0"26' - 0"70' - 0"17' - 2 3/4"7' - 9 1/4"9' - 5 1/2"9' - 4 1/2"
20' - 0"25' - 0"18' - 10"
2"7' - 10"38' - 2"16' - 0"8' - 0"70' - 0"9' - 2"7' - 7"8' - 3"4' - 8 3/4"4' - 0"32' - 2"5' - 0"12' - 0"14' - 10"
1' - 10 1/2"16' - 3" M.O.2' - 3"9' - 3" M.O.2' - 6 1/2"
8 1/2"
3' - 3" M.O1' - 0 1/2"
37' - 2"26' - 10"
64' - 0"
2"5' - 6 3/4"7' - 10 1/2"4' - 5 1/2"20' - 3 1/4"15' - 6 3/4"11' - 0 1/2"8' - 0 3/4"6' - 2 3/4"4' - 0 1/2"2' - 1 1/2"13' - 4 1/2"11' - 4"8' - 8 3/4"33 1/2"63 1/4"
19 3/4"63 1/4"8' - 4 1/4"5' - 10 1/2"6' - 1"13' - 5 1/2"20' - 0 3/4"2' - 5 1/2"
4' - 1"7' - 6 1/4"3' - 11 1/2"19' - 1 1/4"3' - 2"9' - 1"13' - 11"0101
0202
x60" 84"
DBL. GLS DR.
001
x30" 80"002x30" 80"
004
x30" 80"005x72" 80"DBL. DR.003x36" 80"
006
x30" 80"007x36" 80"
008
- UNEXCAVATED -
- UNEXCAVATED -
BEDROOM #5
CPT FLR
EXERCISE RM
CPT FLR
MECH / STOR.
CONCRETE FLR
FAMILY ROOM
CPT FLR
BATH
LVT FLR
WET BAR
LVT FLR
6"6"
LINEN
ISLANDPATIO
STAMPEDCONCRETE
2" SLAB LEDGE
2" SLAB LEDGE2" SLAB LEDGE2" SLAB LEDGE2" STONE LEDGE
W.O.W.O.W.O.
4" LEDGE(2" INSUL./2" SLAB)4" LEDGE(2" INSUL./2" SLAB)48" VANITY
36"x60"FBRGLSSHOWERFAN
SD/CO
BI-PASS DRS.SMOKEDET.FURNWH
F.D.SNKUPPER CAB.54 3/4"15"21"49"54 1/2"90"OverhangR&SLINE OF DECK ABOVE
INTERIOR THERMAL WALL:
(UNEXPOSED WALLS ONLY)1" AIRSPACE2x4 STUDS @ 16" O.C.2x4 TRD. PLATE1/2" GYP BD.
INTERIOR THERMAL WALL:(EXPOSED WALLS ONLY)1" RIGID INSULATION (R-5)2x4 STUDS @ 16" O.C.2x4 TRD. PLATE1/2" GYP BD.
TYPICAL SLAB CONSTRUCTION:4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL
NOTE:SOLID BLOCK ALL JOIST SPACESFIRE CAULK ALL PENETRATIONS IN SOLID BLOCK
EXTERIOR THERMAL WALL:
2" RIGID INSULATION SYSTEM (R-10) APPLIED TO EXTERIORPROVIDE FLASHING
DECK COLUMNS:
3/4" COMPOSITE WRAP TRD. PLYWOOD2x4 FRAMED BOX6x6 TRD. POST ON18" SONO TUBE @ 42"BELOW GRADE
NOTE:
MECHANICAL CONTRACTOR TO VERIFY ALL EQUIPMENT LOCATIONS
NOTE:OPT. FLOOR OUTLETS FOR EXERCISE EQUIPMENT (VERIFY & DETERMINE LOCATIONS)
DECK LANDING COLUMNS:
3/4" COMPOSITE WRAP 6x6 TRD. POST ON18" SONO TUBE @ 42"BELOW GRADE
2x6 BRG WALL2x6 BRG WALL2x6 WALL
PINNED
A.C. PAD GAS & ELECTRICSERVICE LOCATION8' - 0"12' - 0"4' - 0"4' - 0"15' - 0"
178 1
/
2
"
1
19
4
18
1
20
1
18
4
20
5
19
2
19
1
21
x44" 84"
SHTRCK OP'NG
2
18
10
2
13' - 4 3/4"
31' - 4"5' - 6 1/2"
2x6 WALL
63' - 10"
29' - 2"8' - 0"2"2' - 10"2' - 2"16' - 0"6"27' - 6" 1/4" = 1'-0"
1Lower Level
WINDOW NOTE:GENERIC WINDOWS ARE CALLED OUT BY WINDOW FRAME SIZE IN INCHES. EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION. WINDOW MANUFACTURER TO SPECIFY CLOSEST MATCHING SIZES & VERIFY EGRESS COMPLIANCE AND PROVIDE WINDOW SCHEDULE WITH ROUGH OPENINGS. WINDOW & DOOR HEADERS TO BE 2)2x10 UNLESS NOTED (PER MFG. SPECS.)
STRUCTURAL NOTE:BEAM SIZES & ALL STRUCTURAL CONSIDERATIONS SPECIFIED ON THIS SET OF PLANS MUST BE REVIEWED BY THE FLOOR SYSTEM DESIGNER OR BY A STRUCTURAL ENGINEER AND CONFIRMED TO BE STRUCTURALLY SOUND. BASED ON THAT REVIEW IF THERE ARE ANY CHANGES OR ADDED BEAM SIZES, LOCATION , ETC. THESE CHANGES MUST BE BROUGHT TO THE GENERAL CONTRACTORS ATTENTION:DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:21 PM09 Lower LevelPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05DIMENSIONS ARE FROM FACE OF CONCRETE & FACE OF SHEATHING TO CENTER OF STUD.
FLOOR TRUSSES ARE CALLED OUT AT 19.2" O.C.FLOOR SYSTEM DESIGNER VERIFY SPACING ANDADJUST AS ALLOWED BY SPANS
CEILING HEIGHT @ 8'-10" UNLESS NOTEDT.O. WINDOW FRAMES SET @ 84" FROM FLOOR UNLESS NOTED
LOWER LEVEL NOTES:REVISION SCHEDULENumberDate Issued by
UP
UP
BRG.
6"
BRG.
6"
- UNEXCAVATED -
- UNEXCAVATED -
BEDROOM #5
PATIO
BATH
EXERCISE RM
FAMILY ROOM
MECH / STOR.
WET BAR
2)2x10 HDR
2)9-1/4" DROPPED LVL B'M2)2x10 HDR2)9-1/2" LVL CONT. B'M 2)2x10 FLUSH HDR2)2x10 FLUSH HDR2x6 BRG WALL
2x4 BRG WALL2x6 BRG WALL18" FLOOR TRUSSES @ 19.2" O.C.
18" FLOOR TRUSSES @ 19.2" O.C.2x10 JOISTS@ 16" O.C.2x10 JOISTS@ 16" O.C.2x10 JOISTS@ 12" O.C.2)2x10 FLUSH HDR2)2x10 HDR2)2x10 HDR2)2x10 HDR18" FLOOR TRUSSES @ 19.2" O.C.
18" FLOOR TRUSSES @ 19.2" O.C.
2x10 TRD. LEDGER BD.
1
19
4
18
1
20
1
18
4
20
5
19
2
19
1
21
2
182x6 BRG WALL2x6 BRG WALL15' - 2 3/4"
13' - 4 3/4"11' - 0 1/2"8' - 0 3/4"
NOTE:CROSS INDICATES MAIN LEVEL FLOOR TRUSSES
KITCHEN ISLAND
HVAC CHASE5-1/4" x 5-1/4" PSL
5-1/4" x 5-1/4" PSL
5-1/4" x
5-1/4" PSL
3)2x6 STUDS3)2x6 STUDS
2)9-1/4" TREATED FLUSH LVL B'M
2)9-1/4" TREATED FLUSH LVL B'M
2)2x10 FLUSH HDR2)2x10 FLUSH HDR
NOTE:APPLY ACRYLIC ADHESIVE FLASHING TAPE OVER JOISTS (G TAPE OR SIMILAR)
Finished
9 1/4"Finished9 1/4"DECK COLUMNS:3/4" COMPOSITE WRAP TRD. PLYWOOD2x4 FRAMED BOX6x6 TRD. POST ON12" BELL BOTTOM TO 18” TUBE @ 42"BELOW GRADE
6x6 TRD. POST
3
10
PIER #19' - 5"EMBEDMENT MIN.3' - 6"FRMG
6 3/4"
FIN.
9 1/4"5/4"x12"11 1/4"2x10 TRD. JOISTS @ 16" O.C.
COMPOSITE DECKING
DECK COLUMNS:3/4" COMPOSITE WRAP TRD. PLYWOOD2x4 FRAMED BOX6x6 TRD. POST ON12" BELL BOTTOM TO 18” TUBE @ 42"BELOW GRADE
8"MIN. BELL DIA.
18"
CONC. DIA.
12"TRD. 6x6 POSTSIMPSON ABU 66 POST BASE
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:26 PM10 Lower Level StructuralPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05 1/4" = 1'-0"
1Lower Level Structural
NOT AN OFFICAL STRUCTURAL PLAN.
ALL BEAMS, HEADERS, AND GIRDER TRUSSES SHOWN MUST BE SPECIFIED AND DETERMINED BY A LICENSED STRUCTURAL ENGINEER. REFER TO STRUCTURAL DOCUMENTS PROVIDED BY ENGINEER FOR FINAL LOCATIONS, SIZES, AND SPECS.
ROOF/FLOOR GIRDER TRUSSES SHOWN ARE ASSUMED LOCATIONS. NOT ALL NECESSARY GIRDERS MAY BE SHOWN. TRUSS MANUFACTURER TO DETERMINE FINAL LOCATIONS OF GIRDER TRUSSES.
SIZE BEAMS/HEADERS TO ALLOW FOR HVAC RUNS THROUGHOUT ENTIRETY OF HOME.
GRAYED OUT FRAMED WALLS ARE 2X6 BEARING WALLS UNLESS NOTED
FLOOR TRUSSES ARE CALLED OUT AT 19.2” O.C. FLOOR SYSTEM DESIGNER TO VERIFY SPACING AND ADJUST AS ALLOWED BY SPANS
CEILING HEIGHT @ 8'-10" UNLESS NOTEDT.O. WINDOW FRAMES SET @ 84" FROM FLOOR UNLESS NOTED
* ALL HEADERS TO BE:
2) 2x10 U.N.O. w/
1) 2x6 BEARING @ EACH END U.N.O
** ALL BEARING POINTS TO BE CONTINOUS TO FOUNDATION w/
SQUASH BLOCKS
structural notes:REVISION SCHEDULENumberDate Issued by
1 1/2" = 1'-0"
2 Plan View - Deck Columns
1/2" = 1'-0"
3 Section - Deck Column
12" o.c. max for
16' joist span.
Temper
Beam must be
let-in to house.
Post not aligned with
point loads from
window above, align
support posts and
blocking with point
loads above.
BWPs
Above
R
RR
RR
RR
R
R
R
R
RRR
R
R
R
R
R
R
R
R
R
BEDROOM #5
PATIO
BATH
EXERCISE RM
MECH / STOR.
WET BAR
FAMILY ROOM
- UNEXCAVATED -
- UNEXCAVATED -DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:27 PM11 Lower Level Recessed CanLayoutPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05 1/4" = 1'-0"
1Lower Level Recessed Can Layout
NOT AN OFFICAL ELECTRICAL PLAN.
ALL RECESSED CANS SHOWN ARE THE DESIGNER'S BEST SUGGESTIONS FOR CAN LOCATIONS. THIS PLAN TO BE USED FOR TRUSS DESIGN PURPOSES ONLY. OTHER LIGHTING ELEMENTS SUCH AS OUTLETS, LIGHT SWITCHES, PENDANTS, ETC. ARE NOT SHOWN. REFER TO OFFICIAL ELECTRICAL PLANS FOR ALL OTHER ELECTRICAL RELATED ITEMS.
recessed can notes:REVISION SCHEDULENumberDate Issued by
DN
DN
DN
UP
DN
8' - 0"38' - 0"8' - 0"16' - 0"26' - 0"44' - 0"3' - 0"2' - 0"8' - 0"8' - 0"2' - 6"4' - 6"4' - 6"2' - 6"2' - 6"2' - 6"3' - 0"12' - 0"
32' - 0"5' - 0"12' - 0"15' - 0"
37' - 0"27' - 0"
8' - 0"8' - 0"9' - 5 1/2"9' - 6 1/2"
20' - 0"9' - 0"16' - 0"19' - 0"
64' - 0"13' - 0"13' - 0"28' - 0"16' - 0"70' - 0"6 1/2"6 1/2"13' - 3"9' - 3"3' - 0"31' - 6"
5' - 6 1/2"
2' - 6 1/2"3' - 0"
6 1/2"6 1/2"4' - 0"4' - 0"3' - 10 3/4"12' - 9"21' - 4 1/4"70' - 0"16' - 5"7' - 11"4' - 0"11' - 8"15' - 8"24' - 4"
4' - 4"4' - 7"4' - 1 3/4"3"3"
6"6"
24"53 1/2"50"96"44 3/4"24"4' - 5 3/4"6' - 9 1/2"6' - 5 1/2"10' - 0"10' - 3 1/4"33 1/4"30"7' - 2 1/4"5' - 7 1/2"7' - 5 1/2"28 1/4"5' - 4 3/4"33"48"15"48"99"50 1/2"12"33"52"11"12' - 5 3/4"6' - 9 1/2"6' - 5 1/2"2' - 0 1/2"4' - 8 3/4"6' - 2"6' - 3 1/2"9' - 11"5' - 5 1/4"
GARAGE
CONCRETE FLR
DINING RM
WD FLR
GREAT ROOM
WD FLR
FOYER
WD FLR
OFFICE
WD FLR
MUD RM
LVT FLRW.I.C.
LVT FLR
PWDR RM
LVT FLR
PANTRY
WD FLR
KITCHEN
WD FLR
FRONT
PORCH
STAMPEDCONCRETE
DECK
COMPOSITEDECKING
HORZ. METAL RAILING
HORZ. METAL RAILING
GARAGE WALLS:
INSULATE WALLS & CEILINGS5/8" TYPE-X GYP. BD. & FINISH TAPE ON ALL INTERIOR GARAGE WALLS & CEILINGS
LIVABLE AREA OVER GARAGE:
-HEAT DUCT & SEWER WRAPPED & FOAMED-HOLD HEAT DUCT & SEWER TIGHT TO SUBFLOOR-18" BLOWN INSULATION (R-49)
TYPICAL SLAB CONSTRUCTION:4" CONCRETE SLAB PITCHED TOWARDS OVERHEAD DOOR SAND BED GRANULAR FILL
GARAGE FLOOR:SLOPE GARAGE FLOOR TOWARDS OVERHEAD DOORS. SLOPE IN SLAB NOT SHOWN IN CROSS SECTIONS.LINE OF UPPER LEVELx36" 96"FL GLS
110
x30" 96"
105
x30" 96"
109
x30" 96"
107
x36" 96"106x36" 96"ST'L DR104x42" 96"ENTRY DR.111103102
20181917
12
1615
1413
x36" 96"10111
11
081008070907
06
x72" 96"
2-PANEL PATIO DR
108
04040303
05
22
x72" 96"x180" 96"
x36" 96"
2" STONE VENEER2" STONE VENEER
16'-0" x 8'-0" OVERHEAD DOOR9'-0" x 8'-0" OVERHEAD DOORST'L DRSHTRCK OPENINGSHTRCK OPENINGSHTRCK OPENINGF'PL HEARTHGAS FIREPLACEPER MFG. SPECS.36" RANGESNKDW
2-BIN TRASH
16" OVERHANGISLAND
48" REF./FRZ.FULL HGT CABINETUPPER CAB.HOOD VENTUPPER CAB.UPPER CAB.UPPER CAB.
BENCH/HOOKS
R&S
36" VAN.
FANSD/CO
BENCH (OPTIONAL)COLUMN CONSTRUCTION:2)10x10 WD COLUMN w/10x10 WD BEAM
10x10 WD BEAM
2x6 WALL
2x6 WALL
2x6 WALL
12"
12"HORZ. METAL RAILING20 MIN RATED
A.C. PAD GAS & ELECTRICSERVICE LOCATION
1
19
4
18
1
20
1
18
4
20
5
19
2
19
1
21
4"x4" ST'L POST
2
18
193
13 1/2"HVAC CHASEHORZ. METAL RAILING
4' - 5 1/2"6' - 0"8' - 7"6"3' - 6"4' - 3"19' - 9"40
413"OPTIONAL TRANOMS 1/4" = 1'-0"
1Main Level DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:30 PM12 Main LevelPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05WINDOW NOTE:GENERIC WINDOWS ARE CALLED OUT BY WINDOW FRAME SIZE IN INCHES. EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION. WINDOW MANUFACTURER TO SPECIFY CLOSEST MATCHING SIZES & VERIFY EGRESS COMPLIANCE AND PROVIDE WINDOW SCHEDULE WITH ROUGH OPENINGS. WINDOW & DOOR HEADERS TO BE 2)2x10 UNLESS NOTED (PER MFG. SPECS.)
STRUCTURAL NOTE:BEAM SIZES & ALL STRUCTURAL CONSIDERATIONS SPECIFIED ON THIS SET OF PLANS MUST BE REVIEWED BY THE FLOOR SYSTEM DESIGNER OR BY A STRUCTURAL ENGINEER AND CONFIRMED TO BE STRUCTURALLY SOUND. BASED ON THAT REVIEW IF THERE ARE ANY CHANGES OR ADDED BEAM SIZES, LOCATION , ETC. THESE CHANGES MUST BE BROUGHT TO THE GENERAL CONTRACTORS ATTENTION:
DIMENSIONS ARE FROM FACE OF SHEATHING TO CENTER OF STUD
FLOOR TRUSSES ARE CALLED OUT AT 19.2" O.C.FLOOR SYSTEM DESIGNER VERIFY SPACING ANDADJUST AS ALLOWED BY SPANS
CEILING HEIGHT @ 9'-1 1/8" UNLESS NOTEDT.O. WINDOW FRAMES SET @ 96" FROM FLOOR UNLESS NOTED
MAIN LEVEL NOTES:REVISION SCHEDULENumberDate Issued by
DN
DN
DN
UP
DN
BRG.
3"
BRG.
3"
BRG.
6"
BRG.
6"
6 1/2"6 1/2"6 1/2"6 1/2"ROOF TRUSSES @ 24" O.C.2)2x8 HDR @ 7'-6" FROM T.O.F.2)18" LVL B'M @ 7'-6" FROM T.O.F.2)11-1/4" LVL B'M @
7'-6" FROM T.O.F.
2)2x8 HDR @ 7'-6" FROM T.O.F.
2)2x10 HDR2)2x10 HDR2)2x8 HDR2)2x10 HDR2)2x10 HDR2)2x8 HDR3)9-1/2" LVL B'M2)2x8 HDR2)9-1/2" LVL CONT. B'M
24" FLOOR TRUSSES @ 19.2" O.C.
18" FLOOR TRUSSES @ 19.2" O.C.
18" FLOOR TRUSSES @ 19.2" O.C.
18" FLOOR TRUSSES @ 19.2" O.C.
18" FLOOR TRUSSES @ 19.2" O.C.14" FLOOR TRUSSES @ 19.2" O.C.2)16" DROPPED LVL B'M(B.O. B'M @ 8'-1 1/2" FROM M.L.)2)2x10 HDR FLUSH2)2x10 HDR FLUSH2)2x8 HDR
LIVABLE AREA OVER GARAGE:-HEAT DUCT & SEWER WRAPPED & FOAMED-HOLD HEAT DUCT & SEWER TIGHT TO SUBFLOOR-18" BLOWN INSULATION (R-49)
COLUMN CONSTRUCTION:2)10x10 WD COLUMN w/10x10 WD BEAM
10x10 WD BEAM PROPOSED FLOOR GIRDER TRUSS PER MFG. SPEC.BEARING POINTS TO REST ON GIRDER TRUSS BELOW
GARAGE
OFFICE
FRONT
PORCH
FOYER
W.I.C.
MUD RM
PANTRYPWDR RM
KITCHEN
GREAT ROOM
DINING RM
2)16" FLUSH LVL B'M1
19
4
18
1
20
1
18
4
20
5
19
2
19
1
21
2
18
2x6 WALL
HVAC CHASENOTE:CROSS INDICATES UPPER LEVEL FLOOR TRUSSES
NOTE:CROSS INDICATES UPPER LEVEL FLOOR TRUSSES
WET ROOM ABOVE
HANGER SPECIFIED BY SUPPLIER2)2x6 STUDS2)2x6 STUDS2)2x6 STUDS
2)2x6
STUDS
5-1/4" x 5-1/4"
PSL 5-1/4" x 5-1/4" PSL5-1/4" x 5-1/4" PSL
2)9-1/4" FLUSH LVL B'M
5-1/4" x 5-1/4" PSL
5-1/4" x 5-1/4" PSL
5-1/4" x
5-1/4" PSL
3)2x6 STUDS3)2x6 STUDS2)2x8 HDRBEARING POINTS TO REST ON GIRDER TRUSS BELOW
BEARING POINTS TO REST ON GIRDER TRUSS BELOW
2)2x6 STUDS3)2x6 STUDS
5-1/4" x 5-1/4" PSL
5-1/4" x
5-1/4" PSL
2)2x6 STUDS2)2x6 STUDS
5-1/4" x 5-1/4" PSL
2)2x6 STUDS
1-1/2" x 5-1/2" LVL VERSA - STUDS @ 16" O.C.PROVIDE 2) KING STUDS @ EACH OPENING w/BLOCKING @ ALL PANEL EDGES1-1/2" x 5-1/2" LVL VERSA - STUDS @ 16" O.C.PROVIDE 2) KING STUDS @ EACH OPENING w/BLOCKING @ ALL PANEL EDGESBACKSPAN6' - 0"C8 x 11.5 "C" CHANNEL STRINGER FOR END CHANNEL w/END PLATE(1/4" END PLATE ON CHANNEL w/ 2)
3/4" DIA, BOLTS)2) 9 1/4" LVLBEARING POINTS TO REST ON GIRDER TRUSS BELOW
DECK
BRG.3"3)9-1/2" LVL B'MDRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:31 PM13 Main Level StructuralPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05 1/4" = 1'-0"
1Main Level Structural
NOT AN OFFICAL STRUCTURAL PLAN.
ALL BEAMS, HEADERS, AND GIRDER TRUSSES SHOWN MUST BE SPECIFIED AND DETERMINED BY A LICENSED STRUCTURAL ENGINEER. REFER TO STRUCTURAL DOCUMENTS PROVIDED BY ENGINEER FOR FINAL LOCATIONS, SIZES, AND SPECS.
ROOF/FLOOR GIRDER TRUSSES SHOWN ARE APPROXIMATE LOCATIONS. NOT ALL NECESSARY GIRDERS MAY BE SHOWN. TRUSS MANUFACTURER TO DETERMINE FINAL LOCATIONS OF GIRDER TRUSSES.
SIZE BEAMS/HEADERS TO ALLOW FOR HVAC RUNS THROUGHOUT ENTIRETY OF HOME.
GRAYED OUT FRAMED WALLS ARE 2X6 BEARING WALLS UNLESS NOTED
FLOOR TRUSSES ARE CALLED OUT AT 19.2” O.C. FLOOR SYSTEM DESIGNER TO VERIFY SPACING AND ADJUST AS ALLOWED BY SPANS
CEILING HEIGHT @ 9'-1 1/8" UNLESS NOTEDT.O. WINDOW FRAMES SET @ 96" FROM FLOOR UNLESS NOTED
* ALL HEADERS TO BE:
2) 2x10 U.N.O. w/
1) 2x6 BEARING @ EACH END U.N.O
structural notes:REVISION SCHEDULENumberDate Issued by
Verify loads with girder
truss specs, may require
removal of top plates at
bearing due to crushing.
Tempered glass
required on active
leaf side of door.
BWPs
Above
PFH PFH
6
6
6
6
6
8
DN
RRR
RR
RR
RR
R
R
R
R
R
RRR
RRR
R
RR
RR
R
R
R
R
R
R
R
R
R
R
R
RRR
GARAGE
FRONT
PORCH
DINING RM
KITCHEN
GREAT ROOM
PWDR RMPANTRY
MUD RM
W.I.C.
OFFICE
FOYER
DECK
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:32 PM14 Main Level Recessed CanLayoutPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05 1/4" = 1'-0"
1Main Level Recessed Can Layout
NOT AN OFFICAL ELECTRICAL PLAN.
ALL RECESSED CANS SHOWN ARE THE DESIGNER'S BEST SUGGESTIONS FOR CAN LOCATIONS. THIS PLAN TO BE USED FOR TRUSS DESIGN PURPOSES ONLY. OTHER LIGHTING ELEMENTS SUCH AS OUTLETS, LIGHT SWITCHES, PENDANTS, ETC. ARE NOT SHOWN. REFER TO OFFICIAL ELECTRICAL PLANS FOR ALL OTHER ELECTRICAL RELATED ITEMS.
recessed can notes:REVISION SCHEDULENumberDate Issued by
DN
10' - 0"16' - 0"19' - 0"
45' - 0"
6 1/2"6 1/2"2' - 11 3/4"16' - 0 1/4"9' - 9"8' - 8 1/2"19' - 6 1/2"8' - 0"38' - 0"8' - 0"54' - 0"6 1/2"6 1/2"
13' - 0"2' - 6"2' - 6"3' - 0"12' - 0"
18' - 0"12' - 0"15' - 0"
45' - 0"
6 1/2"6 1/2"6 1/2"6 1/2"28' - 0"23' - 0"3' - 0"54' - 0"9' - 1 1/4"3' - 6 1/2"9' - 4"5' - 9 1/2"2' - 0 3/4"7' - 2"8' - 0"
12' - 7 3/4"5' - 8 1/2"3' - 7 1/4"5' - 9 3/4"1' - 10 1/2"7' - 0 1/4"8' - 4"
10' - 6 1/4"5' - 2 1/2"6' - 7"5' - 4 1/2"7' - 3 3/4"7' - 10 1/4"8' - 5 1/2"4' - 0 1/2"4' - 4 1/2"6' - 9 1/2"6' - 5 3/4"56 3/4"37 1/2"15' - 10 1/4"12' - 6"4' - 4 1/2"6' - 9 1/2"5' - 8 1/4"5' - 9 1/2"4' - 2 3/4"4' - 2 3/4"4' - 0 1/2"7' - 10 1/4"4' - 2 3/4"4' - 2 3/4"4' - 0 1/2"OWNER'S SUITE
CPT FLR
OWNER'S
CLOSET
CPT FLR
BEDROOM #2
CPT FLR
OWNER'S
BATH
TILE LFR
WET RM
TILE FLR
WIC #2
CPT FLR
BATH #2
LVT
L'DRY
LVT FLR
BEDROOM #4
CPT FLR
WIC #4
CPT FLR
WIC #3
CPT FLR
J&J BATH
LVT FLR
BEDROOM #3
CPT FLR
LOFT
CPT FLRSTAIRCASEHALLWAY
CPT FLR
BOX VAULT
12" UPSET
56 1/2"24"36"54"37 1/2"54"ISLAND
x36" 80"
204
x30" 80"203x30" 80"
202
x30" 80"
213
x30" 80"
201
x30" 80"
212
x30" 80"PKT DR.
215
x30" 80"
209x30" 80"210x30" 80"211x30" 80"PKT DR.206x30" 80"PKT DR.207x30" 80"
208
x48" 80"DBL. DR.
205
23
25
24
26
27
28
35
3130
29
33
34
39
37 3836
32
x30" 80"PKT DR.
214
R&S
R&S
106" VANITY
FAN
36"x60"FBRGLSSHOWER
FAN
SMOKEDET.
SD/CO
SD/CO
BI-PASS DRS.BUILT-IN (OPT)HORZ. METAL RAILING33"48"15"48"99"50 1/2"12"37"52"11"
SMOKEDET.
SMOKEDET.
SMOKEDET.
FAN SNKUPPER CAB.WSHR w/FLOORDRAIN DRYER
FAN32"x48"FBRGLSSHWR42" VAN.
ATTICACCESS
FAN
97" VAN.30" x 80"HVY GLS DR/PANELTRENCH DRAIN36"x66" FREE-STANDING TUB
39" HALF-WALL
25 1/2"24"39" HALF-WALL24" x 80"HVY GLS DR/PANEL2x6 WALL
2x6 WALL2x6 WALL2x6 WALL2x6 WALL2x6 WALL2x6 WALLR&S
CUSTOM SHELVING
2x6 WALLCUSTOM ZERO-ENTRY TILE SHOWER NOTCH TRUSSES 3"
CROSS HATCH INDICATES FLOOR TRUSSES
1
19
4
18
1
20
1
18
4
20
5
19
2
19
1
21
2
18
/(SEE 3 A20)
1/4" = 1'-0"
1Upper Level DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:35 PM15 Upper LevelPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05WINDOW NOTE:GENERIC WINDOWS ARE CALLED OUT BY WINDOW FRAME SIZE IN INCHES. EXTERIOR WINDOW COLOR TO BE BLACK PER ELEVATION. WINDOW MANUFACTURER TO SPECIFY CLOSEST MATCHING SIZES & VERIFY EGRESS COMPLIANCE AND PROVIDE WINDOW SCHEDULE WITH ROUGH OPENINGS. WINDOW & DOOR HEADERS TO BE 2)2x10 UNLESS NOTED (PER MFG. SPECS.)
STRUCTURAL NOTE:BEAM SIZES & ALL STRUCTURAL CONSIDERATIONS SPECIFIED ON THIS SET OF PLANS MUST BE REVIEWED BY THE FLOOR SYSTEM DESIGNER OR BY A STRUCTURAL ENGINEER AND CONFIRMED TO BE STRUCTURALLY SOUND. BASED ON THAT REVIEW IF THERE ARE ANY CHANGES OR ADDED BEAM SIZES, LOCATION , ETC. THESE CHANGES MUST BE BROUGHT TO THE GENERAL CONTRACTORS ATTENTION:
DIMENSIONS ARE FROM FACE OF SHEATHING TO CENTER OF STUD
FLOOR TRUSSES ARE CALLED OUT AT 19.2" O.C.FLOOR SYSTEM DESIGNER VERIFY SPACING ANDADJUST AS ALLOWED BY SPANS
CEILING HEIGHT @ 8'-1 1/8" UNLESS NOTEDT.O. WINDOW FRAMES SET @ 84" FROM FLOOR UNLESS NOTED
upper LEVEL NOTES:REVISION SCHEDULENumberDate Issued by
DN 30"121 1/2"30"30"119"30"
12" UPSET
OWNER'S SUITE
OWNER'SCLOSET
WET RM
OWNER'SBATH
BEDROOM #2
WIC #2BATH #2
HALLWAY
LOFT
STAIRCASE
BEDROOM #3
J&J BATH
L'DRY
BEDROOM #4
WIC #3
WIC #4
6 1/2"6 1/2"
6 1/2"6 1/2"6 1/2"6 1/2"6 1/2"6 1/2"BOX VAULT
PROPOSED GIRDER TRUSS BY MFG SPEC.
PROPOSED GIRDER TRUSS BY MFG SPEC.ROOF TRUSSES @ 24" O.C.2)2x10 HDR
ROOF TRUSSES @ 24" O.C.
ROOF TRUSSES @ 24" O.C.2)2x10 HDR2)2x8 HDR
2)2x10 HDR2)2x10 HDR2)9-1/4" LVL B'M2)2x10 HDR2)2x8 HDR
2)2x10 HDR2)2X10 HDR2)2x8 HDR 2)2x10 HDR 2)2x10 HDRATTICACCESS
CROSS HATCH INDICATES FLOOR TRUSSES
1
19
4
18
1
20
4
20
5
19
2
19
1
21
PROPOSED GIRDER TRUSS BY MFG SPEC.ROOF TRUSSES @ 24" O.C.
ROOF TRUSSES @ 24" O.C.
ROOF TRUSSES @ 24" O.C.
2
18
/(SEE 3 A20)
HANGER SPECIFIED BY SUPPLIER
5-1/4" x 5-1/4" PSL
5-1/4" x
5-1/4" PSL
2)2x6 STUDS3)2x6 STUDSPROPOSED GIRDER TRUSS BY MFG SPEC.
5-1/4" x
5-1/4" PSL
5-1/4" x 5-1/4" PSL5-1/4" x 5-1/4" PSL
3)2x6 STUDS5-1/4" x 5-1/4" PSL5-1/4" x 5-1/4" PSL
PROPOSED GIRDER TRUSS BY MFG SPEC.PROPOSED GIRDER TRUSS BY MFG SPEC.3)2x6 STUDS
PROPOSED GIRDER TRUSS BY MFG SPEC.2)2x6 STUDS
2)2x6 STUDS
3)2x6 STUDS
5-1/4" x 5-1/4" PSL
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:36 PM16 Upper Level StructuralPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05 1/4" = 1'-0"
1Upper Level Structural
NOT AN OFFICAL STRUCTURAL PLAN.
ALL BEAMS, HEADERS, AND GIRDER TRUSSES SHOWN MUST BE SPECIFIED AND DETERMINED BY A LICENSED STRUCTURAL ENGINEER. REFER TO STRUCTURAL DOCUMENTS PROVIDED BY ENGINEER FOR FINAL LOCATIONS, SIZES, AND SPECS.
ROOF/FLOOR GIRDER TRUSSES SHOWN ARE APPROXIMATE LOCATIONS. NOT ALL NECESSARY GIRDERS MAY BE SHOWN. TRUSS MANUFACTURER TO DETERMINE FINAL LOCATIONS OF GIRDER TRUSSES.
SIZE BEAMS/HEADERS TO ALLOW FOR HVAC RUNS THROUGHOUT ENTIRETY OF HOME.
GRAYED OUT FRAMED WALLS ARE 2X6 BEARING WALLS UNLESS NOTED
ROOF TRUSSES ARE CALLED OUT @ 24” O.C.ROOF SYSTEM DESIGNER TO VERIFY SPACING AND ADJUST AS ALLOWED BY SPANS
TRUSS MANUFACTURER TO VERIFY ALL ENERGY HEELS SHOWN TO ENSURE FINAL EAVE FRAMING DOES NOT CONFLICT WITH FINISHED EXTERIOR WINDOW TRIM AS SHOWN ON ELEVATIONS.
CEILING HEIGHT @ 8'-1 1/8" UNLESS NOTEDT.O. WINDOW FRAMES SET @ 84" FROM FLOOR UNLESS NOTED
* ALL HEADERS TO BE: 2) 2x10 U.N.O. w/ 1) 2x6 BEARING @ EACH END U.N.O
structural notes:REVISION SCHEDULENumberDate Issued by
-Min. 15" clearance to any
obstruction from center of
W.C., 24" in front(typ).
Temper if
within 60"
of tub floor.
Verify loads with girder
truss specs, may require
removal of top plates at
bearing due to crushing.
Verify loads with girder
truss specs, may require
removal of top plates at
bearing due to crushing.
Temper if
within 60"
of floor.
6
6
8
8
8
8
DN
R
R
R
RRRRRRR
R
R
R
R
R
RR
R R
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:37 PM17 Upper Level Recessed CanLayoutPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05 1/4" = 1'-0"
1Upper Level Recessed Can Layout
NOT AN OFFICAL ELECTRICAL PLAN.
ALL RECESSED CANS SHOWN ARE THE DESIGNER'S BEST SUGGESTIONS FOR CAN LOCATIONS. THIS PLAN TO BE USED FOR TRUSS DESIGN PURPOSES ONLY. OTHER LIGHTING ELEMENTS SUCH AS OUTLETS, LIGHT SWITCHES, PENDANTS, ETC. ARE NOT SHOWN. REFER TO OFFICIAL ELECTRICAL PLANS FOR ALL OTHER ELECTRICAL RELATED ITEMS.
recessed can notes:REVISION SCHEDULENumberDate Issued by
First Floor0' - 0"
Second Floor10' - 7 7/8"
Roof18' - 9"
Basement-10' - 4 3/4"
T.O. Footing-10' - 8 1/4"
B.O. Footing-11' - 4 1/4"
Top of Foundation-1' - 8 1/4"
First Floor Clg.9' - 1 1/8"
Basement Clg.-1' - 6 3/4"
Roof Peak25' - 8 5/8"
Grade-2' - 2 1/4"T.O.F. to B.O. Header7' - 7 1/2"T.O.F. to B.O. Eng. Roof Trusses10' - 3 3/8"E.H.6"Ov'Hg
24"
13' - 0"13' - 0"
4"
12"
F73' - 6"3' - 6"GARAGE WALLS:INSULATE WALLS & CEILINGS5/8" TYPE-X GYP. BD. & FINISH TAPE ON ALL INTERIOR GARAGE WALLS & CEILINGS
TYPICAL SLAB CONSTRUCTION:4" CONCRETE SLAB PITCHED TOWARDS OVERHEAD DOOR SAND BED GRANULAR FILL
GARAGE FLOOR:SLOPE GARAGE FLOOR TOWARDS OVERHEAD DOORS. SLOPE IN SLAB NOT SHOWN IN CROSS SECTIONS.
PROPOSED 1/8" / 12" GARAGE SLAB SLOPE VERIFY WITH CONTRACTOR
GARAGE
GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL
B.O. FOOTING @ MIN.42" BELOW GRADE
ROOF TRUSSESPER MFG. SPEC.6"Ov'Hg
24"
F7
First Floor0' - 0"
Second Floor10' - 7 7/8"
Roof18' - 9"
Basement-10' - 4 3/4"
T.O. Footing-10' - 8 1/4"
B.O. Footing-11' - 4 1/4"
Top of Foundation-1' - 8 1/4"
First Floor Clg.9' - 1 1/8"
Basement Clg.-1' - 6 3/4"
Roof Peak25' - 8 5/8"
Grade-2' - 2 1/4"
BEAM FLUSHPER MFG. SPEC.
2X10 TRD. JOISTS @ 12" O.C. w/G TAPE
F5F2
F7
3' - 6"9' - 0"3' - 6"8' - 7 1/8"2' - 5 3/4"6"8' - 1 1/8"2' - 0 3/4"T.O.F. to B.O. Eng. Floor Trusses11' - 0 7/8"T.O.F. to B.O. Eng, Roof Trusses10' - 9 3/8"T.O.F. to Subfloor
30 1/2"121 1/2"30 1/2"12"BOX VAULT
OWNER'S SUITEOWNER'SCLOSETHALLWAYJ&J BATHWIC #3
WIC #4
GARAGEMUD RM KITCHEN DINING RM
BEDROOM #5BATHEXERCISE RM
MECH / STOR.
DECK
Ov'Hg
48"
4"
12"4"
12"
4"
12"Ov'Hg
48"
16' - 0"27' - 0"24' - 0"
Ov'hg
48"
4"
12"
Ov'Hg
48"8' - 10"1' - 6 3/4"9' - 1 1/8"1' - 6 3/4" 8' - 1 1/8"E.H.15 13/16"GARAGE WALLS:INSULATE WALLS & CEILINGS5/8" TYPE-X GYP. BD. & FINISH TAPE ON ALL INTERIOR GARAGE WALLS & CEILINGS
TYPICAL SLAB CONSTRUCTION:
4" CONCRETE SLAB PITCHED TOWARDS OVERHEAD DOOR SAND BED GRANULAR FILL
GARAGE FLOOR:SLOPE GARAGE FLOOR TOWARDS OVERHEAD DOORS. SLOPE IN SLAB NOT
SHOWN IN CROSS SECTIONS.
PROPOSED 1/8" / 12" GARAGE SLAB SLOPE VERIFY WITH CONTRACTOR
GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL
B.O. FOOTING @ MIN.42" BELOW GRADE
GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL
B.O. FOOTING @ MIN.42" BELOW GRADE
ROOF TRUSSESPER MFG. SPEC.
3/4" SUBFLOOR24" FLOOR TRUSSES @ 19.2" O.C.
HABITABLE SPACE OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED.HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R-49).
3/4" SUBFLOOR18" FLOOR TRUSSES @ 19.2" O.C.
3/4" SUBFLOOR18" FLOOR TRUSSES @ 19.2" O.C.
183ROOF TRUSSESPER MFG. SPEC.
TYPICAL SLAB CONSTRUCTION:4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL
06
3
GIRDER TRUSSESPER MFG. SPEC.1 1/2"4/4" x 6"5 1/2"4/4" x 16"15 1/2"19 1/2"18"Overhang
4' - 0"
COMPOSITE SOFFIT
ENGINEERED ROOF TRUSS PER MFG. SPEC.
1/4" 12"METAL DRIP EDGE
5"x5" SQUARE GUTTER
STRUCTURAL FASCIA OR LSL SUB-FASCIA PER MFG. SPEC.
3" MIN. ABS OR PVC OR EQUIVALENTGAS TIGHT PIPE
SEAL ALL JOINTSBETWEEN SLABAND FOUNDATION WALL
4" PERFORATED DRAINTILE W/FILTER FABRIC8"X16" ROCK TRENCH
SEALED SUMP BASKET
MIN 6 MIL OR 3 MIL CROSSLAMINATED POLY SHALL BELAPPED 12" AND PLACED BELOWTHE SLAB AND ON TOP OF 4" MIN. SAND GASPERMEABLE LAYER
INSTALL LABEL READING (RADON REDUCTION SYSTEM) ON THE VENT PIPE AT EACH FLOORAND IN ACCESSIBLE ATTICS
ALL CONTROL JOINTS, ISOLATION JOINTSCONSTRUCTION JOINTS AND ANY OTHERJOINTS IN CONCRETE SLABS SHALL BESEALED WITH CAULK OR SEALANT
SEAL ALL FLOOR OPENINGS
ALL PIPE JOINTS AND FITTINGSTO BE GLUED OR TRANSITIONCOUPLINGS
PROVIDE SPACE FOR FUTUREINSTALLATION OF A FAN*MIN. 24' DIAMETER CENTERED ON THE AXIS OR THE VENT STACK*MIN. VERTICAL DISTANCE 36"
INSTALL LIVE OUTLET IN ATTIC WHEREFUTURE FAN MAY BE INSTALLED
R-4 MIN. INSULATION AROUND PIPE IN UNCONDITIONED SPACES
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:43 PM18 Cross SectionsPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05 1/4" = 1'-0"
1Cross Section - Garage
1/4" = 1'-0"
4Cross Section - Dining Rm/Garage
1" = 1'-0"
3Detail - Front Porch Cornice
1/4" = 1'-0"
2 Detail - Passive Radon System
REVISION SCHEDULENumberDate Issued by
First Floor0' - 0"
Second Floor10' - 7 7/8"
Roof18' - 9"
Basement-10' - 4 3/4"T.O. Footing-10' - 8 1/4"
B.O. Footing-11' - 4 1/4"
Top of Foundation-1' - 8 1/4"
First Floor Clg.9' - 1 1/8"
Basement Clg.-1' - 6 3/4"
Roof Peak25' - 8 5/8"
Grade-2' - 2 1/4"
F2F1
F7 3' - 6"T.O.F. to B.O. Eng. Roof Trusses10' - 3 3/8"E.H.6"Ov'Hg
24"7' - 0"28 7/16"71 1/16"28 7/16"29 3/8"73 3/8"22"18 Risers10' - 7 7/8"17 Risers10' - 4 3/4"9' - 0"9' - 0"8' - 1 1/8"1' - 6 3/4"9' - 1 1/8"1' - 6 3/4"8' - 10"6"E.H.15 13/16"8' - 1 1/8"45' - 0"
Ov'Hg
24"
19' - 0"
GARAGE
BEDROOM #4WIC #3BEDROOM #3LOFT
OFFICEFOYER
MECH / STOR.
WET BAR
TYPICAL SLAB CONSTRUCTION:4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL
GARAGE WALLS:INSULATE WALLS & CEILINGS5/8" TYPE-X GYP. BD. & FINISH TAPE ON ALL INTERIOR GARAGE WALLS & CEILINGS
TYPICAL SLAB CONSTRUCTION:4" CONCRETE SLAB PITCHED TOWARDS OVERHEAD DOOR SAND BED GRANULAR FILL
GARAGE FLOOR:SLOPE GARAGE FLOOR TOWARDS OVERHEAD DOORS. SLOPE IN SLAB NOT SHOWN IN CROSS SECTIONS.
GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL
B.O. FOOTING @ MIN.42" BELOW GRADE
ROOF TRUSSESPER MFG. SPEC.
HABITABLE SPACE OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED.HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R-49).
ROOF TRUSSESPER MFG. SPEC.
3/4" SUBFLOOR18" FLOOR TRUSSES @ 19.2" O.C.
3/4" SUBFLOOR18" FLOOR TRUSSES @ 19.2" O.C.
PROPOSED GIRDER TRUSS PER MFG. SPEC.
BEAM FLUSH TRUSS PER MFG. SPEC.
BEAM FLUSH TRUSS PER MFG. SPEC.
3/4" SUBFLOOR24" FLOOR TRUSSES @ 19.2" O.C.20' - 5 1/4"E.H.7 13/16"Ov'Hg
48"4"
12"
4"
12"
8' - 0"
First Floor0' - 0"
Second Floor10' - 7 7/8"
Roof18' - 9"
Basement-10' - 4 3/4"
T.O. Footing-10' - 8 1/4"
B.O. Footing-11' - 4 1/4"
Top of Foundation-1' - 8 1/4"
First Floor Clg.9' - 1 1/8"
Basement Clg.-1' - 6 3/4"
Roof Peak25' - 8 5/8"
Grade-2' - 2 1/4"28 7/16"71 1/16"28 7/16"29 3/8"73 3/8"22"18 Risers10' - 7 7/8"17 Risers10' - 4 3/4"8' - 10"1' - 6 3/4"9' - 1 1/8"1' - 6 3/4" 8' - 1 1/8"
11"7 1/8"11"7 5/16"GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL
B.O. FOOTING @ MIN.42" BELOW GRADE
F5F3
F9
3' - 6"9' - 0"3' - 0"20' - 5 1/4"Ov'Hg
24"
19' - 0"19' - 0"
4"
12"E.H.7 13/16"E.H.7 13/16"FAMILY ROOM
GREAT ROOM
BATH #2BEDROOM #2
STAIRCASE
FRONTPORCH
12"
TYPICAL STAIRCASE CONSTRUCTION:6'-10" MINIMUM HEADROOM(4) 11- 7/8" STAIR STRINGER w/1-1/8" x 11-1/4" PARTICLE BOARD TREADSPROVIDE 34"-36" HGT HANDRAILS & GUARDS RAILS PER CODE
TYPICAL STAIRCASE LANDING CONSTRUCTION:2-2x8 HEADER3/4" PLYWOOD BACKING2x8 JOISTS @ 16" O.C.3/4" PLYWOOD
3/4" SUBFLOOR18" FLOOR TRUSSES @ 19.2" O.C.
3/4" SUBFLOOR18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSESPER MFG. SPEC.9' - 8 3/8"13"10"10"8' - 10 3/8"18"ROOF TRUSSESPER MFG. SPEC.
FRONT PORCH ROOF CONSTRUCTION:SELF-BITUMINOUS MEMBRANE w/ 3" END OVERLAP EXTEND MEMBRANE 24"-36" ABOVE ABUDDING WALLS3/4" OSB SHEATHING w/STEEL CLIPSENGINEERED ROOF TRUSSES SLOPED @ 1/4" / 12" @ 24" O.C. (PER MFG. SPEC.)COMPOSITE SOFFIT2 TIER COMPOSITE FASCIA
183
TYPICAL SLAB CONSTRUCTION:4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL
BACKSPAN
6' - 0"
2)9-1/4" LVL
C8 x 11.5 "C" CHANNEL STRINGER FOR END CHANNEL
w/END PLATE
(1/4" END PLATE ON
CHANNEL w/ 2) 3/4"
DIA, BOLTS)
Ov'Hg
24"16' - 4 9/16"10' - 11 1/8"1' - 10"10' - 5 9/16"10' - 8 13/16"7' - 11 3/8"First Floor0' - 0"
Second Floor10' - 7 7/8"
Roof18' - 9"
Basement-10' - 4 3/4"T.O. Footing-10' - 8 1/4"B.O. Footing-11' - 4 1/4"
Top of Foundation-1' - 8 1/4"
First Floor Clg.9' - 1 1/8"
Basement Clg.-1' - 6 3/4"
Grade-2' - 2 1/4"3' - 6"F5
Ov'Hg
48"
8' - 0"8' - 0"
4"
12"8' - 1 1/8"1' - 6 3/4"9' - 1 1/8"1' - 6 3/4"8' - 10"30 1/2"119"30 1/2"12"E.H.15 13/16"BEDROOM #5
DINING RM
OWNER'S SUITEBOX VAULT
GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL
B.O. FOOTING @ MIN.42" BELOW GRADE
3/4" SUBFLOOR18" FLOOR TRUSSES @ 19.2" O.C.
3/4" SUBFLOOR18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSESPER MFG. SPEC.
F1 9' - 0"Ov'Hg
48"
First Floor0' - 0"10"106 3/8"10"3" 10"109 1/8"7 1/4"10"x10" TIMBER POSTS10"x10" TIMBER BEAM
ST'L KNIFE PLATE CONNECTOR EMBEDDED IN CONCRETE PORCH w/ ANCHOR BOLTSWITH T-REX CONNECTOR
THRU BOLTS
THRU BOLTS
6 1/2"
10"3"10"6 1/2"10"1/2"10"x10" TIMBER POSTS10"x10" TIMBER POSTS
THRU BOLTSTHRU BOLTS
ST'L KNIFE PLATE CONNECTOR EMBEDDED IN CONCRETE PORCH w/ ANCHOR BOLTS WITH T-REX CONNECTOR.
LINE OF 10x10 TIMBER BEAM
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:49 PM19 Cross SectionsPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05 1/4" = 1'-0"
5Cross Section - Garage/Staircase
1/4" = 1'-0"
1Cross Section - Great Rm/Staircase 1/4" = 1'-0"
2 Cross Section - Dining Rm
3/4" = 1'-0"
4Detail - Timber Column/Beam
1 1/2" = 1'-0"
3Detail - Timber Columns REVISION SCHEDULENumberDate Issued by
First Floor0' - 0"
Second Floor10' - 7 7/8"
Roof18' - 9"
Basement-10' - 4 3/4"
T.O. Footing-10' - 8 1/4"
B.O. Footing-11' - 4 1/4"
Top of Foundation-1' - 8 1/4"
First Floor Clg.9' - 1 1/8"
Basement Clg.-1' - 6 3/4"
Roof Peak25' - 8 5/8"
Grade-2' - 2 1/4"
F83' - 6"3' - 6"T.O.F. to B.O. Framing7' - 6 3/4"T.O.F. to T.O. Framing13' - 2 5/8"18"8' - 1 1/8"2' - 0 3/4"T.O.F. to B.O. Eng Floor Trusses10' - 3 3/8"T.O.F. to B.O. Header7' - 7 1/2"E.H.15 13/16"28' - 0"23' - 0"
DECKGARAGE
BEDROOM #4L'DRY
GARAGE WALLS:INSULATE WALLS & CEILINGS5/8" TYPE-X GYP. BD. & FINISH TAPE ON ALL INTERIOR GARAGE WALLS & CEILINGS
TYPICAL SLAB CONSTRUCTION:4" CONCRETE SLAB PITCHED TOWARDS OVERHEAD DOOR SAND BED GRANULAR FILL
GARAGE FLOOR:SLOPE GARAGE FLOOR TOWARDS OVERHEAD DOORS. SLOPE IN SLAB NOT SHOWN IN CROSS SECTIONS.
PROPOSED 1/8" / 12" GARAGE SLAB SLOPE VERIFY WITH CONTRACTOR
GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL
B.O. FOOTING @ MIN.42" BELOW GRADE
ROOF TRUSSESPER MFG. SPEC.ROOF TRUSSESPER MFG. SPEC.
4"
12"
4"
12"
BEAM FLUSHPER MFG. SPEC.
2X10 TRD. JOISTS @ 16" O.C. w/G TAPE
3/4" SUBFLOOR24" FLOOR TRUSSES @ 19.2" O.C.
202
20
3
HABITABLE SPACE OVER UNCONDITIONED SPACE REQUIRES HEAT DUCT & SEWER PIPES TO BE WRAPPED & FOAMED.HEAT DUCT & SEWER PIPES WILL BE HELD TIGHT TO SUBFLOOR & 18" BLOWN INSULATION (R-49).
F7
Ov'Hg
48"
Ov'Hg
48"
3' - 0"
First Floor0' - 0"
Second Floor10' - 7 7/8"
Roof18' - 9"
Basement-10' - 4 3/4"
T.O. Footing-10' - 8 1/4"B.O. Footing-11' - 4 1/4"
Top of Foundation-1' - 8 1/4"
First Floor Clg.9' - 1 1/8"
Basement Clg.-1' - 6 3/4"
Grade-2' - 2 1/4"
F19' - 0"8' - 1 1/8"1' - 6 3/4"9' - 1 1/8"1' - 6 3/4"8' - 10"E.H.7 13/16"4"
12"
Ov'Hg
24"
35' - 0"
BATH
FAMILY ROOM
GREAT ROOM KITCHEN
OWNER'SCLOSET
OWNER'SBATHBEDROOM #2
3/4" SUBFLOOR18" FLOOR TRUSSES @ 19.2" O.C.
ROOF TRUSSESPER MFG. SPEC.
3/4" SUBFLOOR18" FLOOR TRUSSES @ 19.2" O.C.BEAM DROPPEDPER MFG. SPEC.
BEAM DROPPEDPER MFG. SPEC.
TYPICAL SLAB CONSTRUCTION:4" CONCRETE SLAB OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL sheetrock Opening84"Sheetrock Opening96"Ov'Hg
24"
F1 9' - 0"Overhang
18"
COMPOSITE SOFFIT4/4" x 12"11 1/4"2x10 JOISTS @ 16" O.C.
1/4" 12"
METAL DRIP EDGE
7/8" WEDGE BLOCK7/8"GARAGE CANOPY CONSTRUCTION:
SELF-BITUMINOUS MEMBRANE w/ 3" END OVERLAP EXTEND MEMBRANE 24"-36" ABOVE ABUDDING WALLS3/4" OSB SHEATHING w/STEEL CLIPSWEDGE BLOCKING TO CREATE 1/4" / 12" SLOPE2x10 JOISTS @ 16" O.C. w/BLOCKING IN BETWEENCOMPOSITE SOFFITCOMPOSITE FASCIA 2' - 3 1/4"1' - 0 3/4"
CANOPY HANGER DESIGN PER STRUCTURAL ENGINEER
PROVIDE SOLID BACKING FOR CANOPY HANGER
2' - 0 3/4"10 1/2"2' - 11 1/4"3/4" SUBFLOOR24" FLOOR TRUSSES @ 19.2" O.C.2x6 FRAMING2x6 FRAMING3/4"METAL DRIP EDGE
3/4" WEDGE BLOCK
GARAGE PARAPET CONSTRUCTION:SELF-BITUMINOUS MEMBRANE w/ 3" END OVERLAP EXTEND MEMBRANE 24"-36" ABOVE ABUDDING WALLS3/4" OSB SHEATHING w/STEEL CLIPSWEDGE BLOCKING TO CREATE 1/4" / 12" SLOPE2x6 FRAMING @ 16" O.C.EXTERIOR CLADDING PER PLAN
EXTERIOR CLADDING PER PLAN
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:05:55 PM20 Cross SectionsPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05 1/4" = 1'-0"
1Cross Section - Bdrm#4/L'dry
1/4" = 1'-0"
4Cross Section - Great Rm/Kitchen
1 1/2" = 1'-0"
2 Detail - Garage Canopy
1 1/2" = 1'-0"
3Detail - Garage Parapet REVISION SCHEDULENumberDate Issued by
Upper Level Ceiling Height8' - 1 1/8"1' - 6 3/4"Main Level Ceiling Hieght9' - 1 1/8"1' - 6 3/4"Lower Level Ceiling Height8' - 10"3' - 6"Lower Level Window Frame Height7' - 0"Main Level Window Frame Height8' - 0"F5
F3
9' - 0"Lower Level Ceiling Height8' - 10"1' - 6 3/4"Main Level Ceiling Height9' - 1 1/8"1' - 6 3/4"Upper Level Ceiling Height8' - 1 1/8"E.H.7 13/16"4"
12"
Overhang
24"Upper Level Window Frame Height7' - 0"Main Level Window Frame Height8' - 0"4"
12"
Overhang
24"
06
2
ROOF, CEILING & EAVE
CONSTRUCTION:
WALL
CONSTRUCTION:
FOUNDATION WALL &
BASEMENT SLAB
CONSTRUCTION:
MAIN LEVEL
CONSTRUCTION:
UPPER LEVEL
CONSTRUCTION:
ARCHITECTURAL GRADE ASPHALT SHINGLES#15FELT & ICE & WATER SHIELD (6'-0")1/2" OSB SHEATHING w/STEEL CLIPSTRUSSES @ 24" O.C. (PER MFG. SPEC.)BAFFLES w/1" AIR SPACE2X4 LOOKOUTS2X8 SUB FASCIA w/ 4/4"x8" COMPOSITE FASCIA 5"x5" SQUARE GUTTERSCOMPOSITE VENTED SOFFITSCOMPOSITE FRIEZE BOARDSR-50 BLOWN INSULATION
POLY VAPOR BARRIER5/8" GYP. BRD. CEILING
3/4" T&G PLYWOOD SUBFLOOR GLUED & SCREWED18" FLOOR TRUSSES @ 19.2" O.C.(FLOOR SYSTEM DESIGNER TO VERIFY SIZE & SPACING BASED ON SPANS)5/8" GYP. BRD. ON CEILINGSPRAY INSULATE RIMS (R-21)
SIDING PER ELEVATION
HOUSE WRAP (WRAP WINDOWS PER MFG. SPEC.)1/2" OSB SHEATHING2X6 STUDS @16" O.C.DBL. TOP PLATER-21 WALL INSULATION4 MIL POLY VAPOR BARRIER1/2" GYP. BRD.2X6 SOLE PLATEALL DETAILS TO CONFORM W/ ENERGY CODE
3/4" T&G PLYWOOD SUBFLOOR GLUED & SCREWED18" FLOOR TRUSSES @ 19.2" O.C.(FLOOR SYSTEM DESIGNER TO VERIFY SIZE & SPACING BASED ON SPANS)FLASHING UNDER SILLS & STOOPSTREATED 2X6 SILL PLATE w/ SEALER1/2" ANCHOR BOLTS @ 6' O.C. & 1' FROM CORNERS5/8" GYP. BRD. ON CEILINGSPRAY INSULATE RIMS (R-21)
WATERPROOFINGEXTERIOR THERMAL WALL:2" RIGID INSULATION (R-10) APPLIED TO EXTERIOR, PROVIDE FLASHING TO COVER EXPOSED INSULATIONPOURED CONC. WALL PER PLANREINFORCE WALLS PER CODE AND ENGINEER'S SPECIFICATIONS20" X 8" CONTINUOUS CONC. FOOTING UNLESS OTHERWISE NOTED4" POURED CONCRETE SLAB
VAPOR/MOISTURE BARRIER PER IRC SECTION 506 EXTENDING UP THE WALL AND SEALED TO FOUNDATION WALL2" RIGID INSULATION4" SAND/AGGREGATE FILL
INTERIOR & EXTERIOR 4" DIA. PERFORATED DRAIN TILE PIPED TO SUMP BASKET
INTERIOR THERMAL WALL:1" RIGID INSULATION (R-5)2x4 STUDS @ 16" O.C.2x4 TRD. PLATE1/2" GYP BD.
CONCRETE - MASONARY WALL
CEMENTITIOUS ADHESIVE/WATERPROOFING
EXPANDED POLYSTRYRENE BOARD
CEMENTITIOUS BASE COAT
REINFORCED FIBERGLASS MESH
CEMENTITIOUS BASE COAT
FINISH
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:06:01 PM21 Schedules & DetailsPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05D O O R S C H E D U L E
Tag Door SizeDoor TypeQuantity
Head
HeightLevel Room Name Comments
001 60" x 84" Double Swing - Glass1 7' - 0"Basement FAMILY ROOM
002 30" x 80" Single - Swing1 6' - 8"Basement BEDROOM #5
003 72" x 80" Double Swing1 6' - 8"Basement BEDROOM #5
004 30" x 80" Single - Swing1 6' - 8"BasementBATH
005 30" x 80" Single - Swing1 6' - 8"BasementBATH
006 36" x 80" Single - Swing1 6' - 8"Basement FAMILY ROOM
007 30" x 80" Single - Swing1 6' - 8"Basement WET BAR
008 36" x 80" Single - Swing1 6' - 8"Basement MECH / STOR.
101 36" x 96" Single - Swing1 8' - 0"GradeGARAGE Steel Door
102 9'-0" x 8'-0" Overhead Garage Door - Sectional1 8' - 0"GradeGARAGE
103 16'-0" x 8'-0" Overhead Garage Door - Sectional1 8' - 0"GradeGARAGE
104 36" x 96" Single - Swing - Steel1 8' - 0"First Floor GARAGE 20 Min. Rated
105 30" x 96" Single - Swing1 8' - 0"First Floor MUD RM
106 36" x 96" Single - Swing1 8' - 0"First Floor MUD RM
107 30" x 96" Single - Swing1 8' - 0"First Floor PANTRY
108 72" x 96" Double Sliding - Glass1 8' - 0"First Floor DINING RM
109 30" x 96" Single - Swing1 8' - 0"First FloorFOYER
110 36" x 96" Single - Swing - Glass1 8' - 0"First FloorFOYER
111 42" x 96" Single - Swing - Glass1 8' - 0"First Floor FRONT PORCH
201 30" x 80" Single - Swing1 6' - 8"Second Floor BEDROOM #4
202 30" x 80" Single - Swing1 6' - 8"Second Floor BEDROOM #4
203 30" x 80" Single - Swing1 6' - 8"Second Floor HALLWAY
204 36" x 80" Single - Swing1 6' - 8"Second Floor HALLWAY
205 48" x 80" Double Swing1 6' - 8"Second Floor HALLWAY
206 30" x 80" Pocket - Single1 6' - 8"Second Floor OWNER'S CLOSET
207 30" x 80" Pocket - Single1 6' - 8"Second Floor OWNER'S SUITE
208 30" x 80" Single - Swing1 6' - 8"Second Floor OWNER'S BATH
209 30" x 80" Single - Swing1 6' - 8"Second Floor LOFT
210 30" x 80" Single - Swing1 6' - 8"Second Floor WIC #2
211 30" x 80" Single - Swing1 6' - 8"Second Floor BEDROOM #2
212 30" x 80" Single - Swing1 6' - 8"Second Floor LOFT
213 30" x 80" Single - Swing1 6' - 8"Second Floor BEDROOM #3
214 30" x 80" Pocket - Single1 6' - 8"Second Floor J&J BATH
215 30" x 80" Pocket - Single1 6' - 8"Second Floor J&J BATH
Grand total: 34
W I N D O W S C H E D U L E
Tag Window Size Window Type Quantity Head Height Level Room Location Comments
01 36" x 66"Casement2 7' - 0"BasementBEDROOM #5
02 48" x 66"Fixed2 7' - 0"BasementPATIO
22 48" x 24"Fixed1 7' - 6"Top of Foundation GARAGE
03 36" x 18"Awning2 2' - 0"First FloorDECK
04 36" x 72"Fixed2 8' - 0"First FloorDECK
05 48" x 18"Awning1 2' - 0"First FloorDINING RM
06 48" x 72"Fixed1 8' - 0"First FloorDINING RM
07 48" x 18"Awning2 2' - 0"First FloorGREAT ROOM
08 48" x 72"Fixed2 8' - 0"First FloorGREAT ROOM
09 60" x 18"Fixed1 2' - 0"First FloorGREAT ROOM
10 60" x 72"Fixed1 8' - 0"First FloorGREAT ROOM
11 48" x 24"Fixed2 8' - 0"First FloorGREAT ROOM
12 30" x 72"Fixed1 8' - 0"First FloorFOYER
13 54" x 72"Fixed1 8' - 0"First FloorFRONT PORCH
14 30" x 72"Fixed1 8' - 0"First FloorFOYER
15 30" x 18"Awning1 2' - 0"First FloorFRONT PORCH
16 30" x 72"Casement1 8' - 0"First FloorFRONT PORCH
17 54" x 18"Fixed1 2' - 0"First FloorOFFICE
18 54" x 72"Fixed1 8' - 0"First FloorOFFICE
19 30" x 18"Awning1 2' - 0"First FloorOFFICE
20 30" x 72"Casement1 8' - 0"First FloorOFFICE
40 48" x 24"Transom1 8' - 0"First FloorDINING RMOptional
41 48" x 24"Transom1 8' - 0"First FloorDINING RMOptional
23 30" x 66"Casement1 7' - 0"Second FloorOWNER'S SUITE
24 54" x 66"Fixed1 7' - 0"Second FloorOWNER'S SUITE
25 30" x 66"Casement1 7' - 0"Second FloorOWNER'S SUITE
26 48" x 66"Fixed1 7' - 0"Second FloorWET RM
27 30" x 66"Casement1 7' - 0"Second FloorBEDROOM #2
28 30" x 66"Casement1 7' - 0"Second FloorBEDROOM #2
29 30" x 66"Fixed1 7' - 0"Second FloorSTAIRCASE
30 54" x 66"Fixed1 7' - 0"Second FloorSTAIRCASE
31 30" x 66"Fixed1 7' - 0"Second FloorSTAIRCASE
32 42" x 66"Fixed1 7' - 0"Second FloorLOFT
33 30" x 66"Casement1 7' - 0"Second FloorBEDROOM #3
34 54" x 66"Fixed1 7' - 0"Second FloorBEDROOM #3
35 30" x 66"Casement1 7' - 0"Second FloorBEDROOM #3
36 36" x 24"Fixed1 7' - 0"Second FloorWIC #4
37 30" x 66"Casement1 7' - 0"Second FloorBEDROOM #4
38 54" x 66"Fixed1 7' - 0"Second FloorBEDROOM #4
39 30" x 66"Casement1 7' - 0"Second FloorBEDROOM #4
Total Windows: 47
1/2" = 1'-0"
1Detail - Typical Wall Section REVISION SCHEDULENumberDate Issued by
1" = 1'-0"
3 Detail - Exterior Insulation Finish System
UP
DN
DN
DN
UPDN
DN
260 SF
PATIO
1004 SF
LOWER LEVEL
203 SF
MECH
183 SF
EXERCISE RM
372 SF
DECK
1488 SF
MAIN LEVEL
857 SF
GARAGE
120 SF
FRONT PORCH
1699 SF
UPPER LEVEL
117 SFSTAIRSABBREVIATIONS LIST
= AIR CONDITIONING= ABOVE FINISHED FLOOR= ALUMINIUM= BOTTOM CHORD BEARING= BOARD= BEDROOM= BUILT IN= BEAM= BOTTOM OF= BEARING= BASEMENT= CABINETS= CANTLIEVER= CEILING= CENTER LINE= CASED OPENING= CONCRETE= CONTINUOUS= CARPET= CERAMIC TILE= CASEMENT= DOUBLE= DEMOLISH OR DEMOLITION= DOUBLE HUNG= DIAMETER= DIMENSION(S)= DOWN= DRYWALL OPENING= DOOR= DISHWASHER= DRAWING= EACH= ENERGY HEEL= ELECTRIC= ELEVATIONS OR ELEVATOR= ENGINEER= ETHYLENE PROPYLENE DIENE M-CLASS= EQUAL= EXTERIOR= EXISTING= FLOOR DRAIN= FINISHED= FLOOR= FOUNDATION= FIREPLACE= FRAMING= FREEZER= FOOTING= FURNITURE= FUTURE= FIXED= GLIDER= GIRDER TRUSS= GYPSUM= GYPSUM BOARD= HEADER= HEIGHT= HEATING VENTILATION AIR CONDITIONING= IN FLOOR HEAT= INSULATION= INTERIOR= LANDING= LINEN= LOCKERS= LOWER LEVEL= LOOKOUT= LUXURY VINYL TILE= LUXURY VINYL PLANK= MAXIMUM= MECHANICAL= MANUFACTURE(R)= MINIMUM= MAIN LEVEL= MASONRY OPENING= NUMBER= NOMINAL= ON CENTER= OFFICE= OPENING= OPTION(AL)= POLISHED CONCRETE= PERIMETER= POCKET= PLUMBING= PLYWOOD= POWDER= POLYVINYL CHLORIDE= REFRIGERATOR= REQUIRED= ROOM= ROD & SHELF= SIMULATED DIVIDED LITE= SMOKE DETECTOR= SMOKE / CARBON MONOXIDE DETECTOR= SINGLE HUNG= SHELVING= SHELVES= SIMILAR OR SIMULATOR= SLIDER= SINK= SPECIFICATION(S) OR SPECIFIED= STEEL= STORAGE= STRUCTURAL= SQUARE FOOTAGE= TO BE DETERMINED= TOP CHORD BEARING= TONGUE AND GROOVE= TOP OF= TREATED= TRANSOM= TYPICAL= UPPER LEVEL= UNFINISHED= VANITY= WOOD= WINDOW= WALK IN CLOSET= WITH= WALKOUT= WASHER
A.C.A.F.F.ALUM.B.C.B.BD.BDRM.B.I.B'MB.O.BRG.BSMT.CABS.CANT.CLG.C.L.C.O.CONC.CONT.CPT.C.T.CSMTDBL.DEMOD.H.DIA.DIM(S)DN.D.O.DR.D.W.DWG.EA.E.H.ELEC.ELEV.ENG.EPDMEQ.EXT.EXST.F.D.FIN.FLR.FND.F/PFRMG.FRZ.FTG.FURN.FUT.FX.GLD.G.T.GYP.GYP. BD.HDR.HGT.HVACI.F.H.INSUL.INT.LDG.LIN.LKRS.L.L.L.O.L.V.T.L.V.P.MAX.MECH.MFG.MIN.M.L.M.O.NO.NOM.O.C.OFF.OP'NGOPT.P. CONC.PERM.PKT.PLMG.PLWD.PWDRPVCREF.REQDRM.R&SS.D.L.SD.SD/COS.H.SHLVG.SHLVS.SIM.SLD.SNKSPEC.ST'LST'RGSTRUC.SQ. FTG.TBD.T.C.B.T>.O.TRD.TRSM.TYP.U.L.UNFIN.VTY.W'DWDWW.I.C.W/W.O.WSHR.10' - 6"11' - 0"30' - 0"
GENERAL NOTES
1. ALL EXTERIOR WALLS TO BE CONSTRUCTED OF 2x6 STUDS @ 16" O.C.
2. ALL INTERIOR WALLS TO BE CONSTRUCTED OF 2x4 STUDS @ 16" O.C. (UNLESS OTHERWISE NOTED)
3. WALLS ADJACENT TO GARAGE SPACE SHALL BE 2x6 WITH A 1 HR. FIRE RATING
4. STRUCTURAL WALLS TO HAVE A FIRE RATING OF 1 HR.
5. ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF SHEATHING
6. PROVIDE ROOF VENTILATION 1 SQ.FT. PER 300 SQ.FT. OF ROOF AREA. 50% AT RIDGE AND 50% AT SOFFIT-MIN
7.ALL INTERIOR DOOR HEAD HEIGHT TO BE VERIFIED BY BUILDER UNLESS OTHERWISE NOTED. UNDERCUT MIN 1"
8. ALL STRUCTURAL MEMBERS TO BE VERIFIED BY MANF. AND A STRUCTURAL ENGINEER.
9. ALL WINDOW UNITS ABOVE TUB DECK AND/OR WITHIN 18" OF THE FLOOR AND/OR 24" OF A DOORWAY SHALL BE TEMPERED GLASS
10. PROVIDE AN APPROVED ICE AND WATER ROOFING STARTER EDGE PER CODE OR EQUIVALENT
11. WRAP ALL CANTILEVERS WITH AN APPROVED POLY AND SPRAY FOAM FLOOR
12. SLOPE FINISHED GRADE AWAY FROM THE HOUSE ON ALL SIDES
13. 1/2" AIR SPACE ON EACH SIDE OF MICRO-LAM BEAM & MIN 3" BEARING ON CONCRETE
14. EXTERIOR RAILING TO BE MIN OF 36" HIGH AND BUILT AS TO NOT ALLOW A 4" SPHERE TO PASS THROUGH
15. ALL COMPONENTS TO BE INSTALLED TO MANF. SPEC OR LOCAL CODE
16. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY IS TO BE PRESSURE TREATED OR WOOD SPECIES THAT HAS A NATURAL RESISTANCE TO DECAY
17. PROVIDE A WATER RESISTIVE GYP BOARD AROUND ALL SHOWERS AND TUBS
18. LIGHT OR FAN HOUSING SYSTEM RECESSED THROUGH AN EXTERIOR VAPOR BARRIER SHALL BE OF THE AIR SEALED TYPE OR BE BOXED AND SEALED PER CODE
19. PROVIDE DRAFT STOPS PER UBC 708.3
20. FIRE BLOCK ALL CHASES AT EACH FLOOR-CEILING ASSEMBLY OR AT 10' MAX INTERVALS
21. ALL SMOKE DETECTORS TO BE HARD WIRED WITH BATTERY BACKUP PER CODE
22. MAINTAIN A 6" SEPARATION BETWEEN GRADE AND WOOD
23. CAULK AND FLASH AROUND ALL EXTERIOR OPENINGS
24. PLUMBING PENETRATIONS IN WALL ASSEMBLY SHALL BE FIRE CAULKED WITH LISTED MATERIALS
25. BLOCK PATIO DOORS WITHOUT A DECK
26. SMOKE DETECTORS SHALL BE MIN 16" AWAY FROM WALL AND INSTALL TO MANF. SPEC
27. NO OPENING IN ROOF WITHIN 5' OF PROPERTY LINES
28. 10% OF THE FLOOR AREA IS REQUIRED FOR LIGHT AND VENTILATION IN ALL HABITABLE ROOMS
29. ON EXTERIOR, GRIPPABLE HANDRAILS 34" TO 36" IN HEIGHT FROM THE NOSE OF THE STAIRS
30. COMBUSTION AIR DUCTS 12" OFF THE FLOOR OR RETURN AIR PLENUM WHEN REQUIRED (IMC703)
31. PROVIDE PLUMBING ACCESS AT ALL TUBS EXCEPT WHEN TRAPS & OVERFLOW GLUED
32. PROVIDE 50 cfm OR 20 cfm CONTINUOUS VENTILATION OR OPERABLE WINDOW (ASHRAE 62-2001 6.1)
33. DRYER VENT TO THE EXTERIOR- INSULATE LAST 3 FEET MIN 36" CLEARANCE TO OTHER OPENINGS: (IMC504.4, 401.52 AND 604.1)
34. CERAMIC TILE TO BE APPLIED OVER GREEN BOARD, CEMENT BOARD, WONDER BOARD OR OTHER APPROVED MATERIAL TO A HEIGHT OF 70" ABOVE DRAIN INLET IN SHOWERS. CEMENT BOARD MUST BE USED ON EXTERIOR WALLS UNDERNEATH TILE AND OVER THE VAPOR BARRIER (R307)
35. TRUSS PLANS STAMPED AND APPROVED BY MANF. SHALL BE ON THE JOB SITE. ALTERATIONS TO TRUSSES REQUIRE AN ENGINEER'S APPROVAL
36. RAFTERS SHALL BE FRAMED TO MIN 1" THICK RIDGE BOARD NOT LESS THAN THE DEPTH OF THE CUT END OF THE RAFTERS OR NAILED TO EACH OTHER WITH A GUSSET PLATE A TIE. THE RIDGE BOARD MUST BE SUPPORTED ON END WALL OR MIN 2x4 COLLAR TIES ARE REQUIRED AT MIN 4" O.C.
37. 4-MIL VAPOR BARRIER ON WARM IN WINTER SIDE OF EXTERIOR WALLS AND CEILING. FIRE RETARDANT VAPOR BARRIER MAY BE LEFT UNCOVERED
38. WIND-WASH AT AL EAVES, CORNERS, OVERHANGS, AND BY WINDOWS. SHEATHING INSULATION DAM @ CEILING CHANGES
39. WEATHER-RESISTIVE BARRIER-i.e. BUILDING WRAP TABLE R703.4
40. HOT WATER PIPING LOCATED OUTSIDE OF CONDITIONED SPACE WILL BE INSULATED TO AT LEAST R-3
41. ATTIC ACCESS DOORS FROM CONDITIONED TO UNCONDITIONED SPACES SHALL BE WEATHERED-STRIPPED AND INSULATED.
42. NEW WOOD-BURNING FIREPLACES WILL HAVE TIGHT-FITTING FLUE DAMPERS AND OUTDOOR COMBUSTION AIR.
43. FOR WINDOWS WHERE THE LOWEST PART OF THE WINDOW OPENING IS MORE THAN 6' ABOVE THE GROUND, THE LOWEST PART OF OPENING SHALL BE MIN. OF 36" ABOVE THE FINISHED FLOOR. EXCEPTIONS INCLUDE WINDOWS THAT DO NOT OPEN MORE THAN 4", WINDOWS WITH FALL PROTECTION, AND WINDOWS THAT HAVE OPENING CONTROL DEVICES.
44. DWELLINGS WITH ATTACHED GARAGES OR FUEL FIRED EQUIPMENT MUST BE EQUIPPED WITH CARBON MONOXIDE ALARMS OUTSIDE OF, BUT NO FURTHER THAN 10' FROM , EACH SLEEPING AREA OR BEDROOM.
45. FOOTINGS SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 5,000 psi.
46. A MIN. 1/2" GYPSUM BOARD MEMBRANE, OR 5/8" WOOD STRUCTURAL PANEL MEMBRANE, SHALL BE PROVIDED ON THE UNDERSIDE OF FLOOR ASSEMBLIES. EXCEPTIONS A.DWELLINGS EQUIPPED WITH SPRINKLER SYSTEM. B.CRAWLSPACES C.PORTIONS OF FLOOR ASSEMBLIES WITH PROPORTIONALLY SMALL AREA. D. FLOOR ASSEMBLIES CONSTRUCTED OF SOLID SAWN LUMBER OR STRUCTURAL COMPOSITE LUMBER WITH MIN. NOMINAL DIMENSIONS OF 2"x10".
47. DECKS SUPPORTED BY ATTACHMENT TO AN EXTERIOR WALL SHALL BE POSITIVELY ANCHORED TO THE PRIMARY STRUCTURE AND DESIGNED FOR BOTH VERTICAL AND LATERAL LOADS.
48. FLASHING WITH A MIN. 3 1/2" VERTICAL ATTACHMENT FLANGE IS REQUIRED AT THE INTERSECTION OF THE FOUNDATION AND RIM JOIST FRAMING WHEN THE EXTERIOR WALL COVERING DOES NOT LAP THE FOUNDATION INSULATION. THE FLASHING MUST EXTEND A MIN. OF 1" BELOW THE FOUNDATION PLATE LINE, AND THE REQUIRED WATER-RESISTIVE BARRIER MUST LAP OVER THE ATTACHMENT FLANGE.
49. BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS
50. DAVID CHARLEZ DESIGNS RECOMMENDS THE CONTRACTOR OFFERS THE HOMEOWNER AN OPTIONAL LIGHTNING PROTECTION SYSTEM THAT MEETS NATIONAL SAFETY STANDARDS OF NFPA 780 AND UL 96, UL96A INCLUDING STRIKE TERMINATION DEVICES, DOWN CONDUCTORS, BONDING, AND SURGE PROTECTION.
51. METAL ROOF PANELS, DECKING, SLOPES, MATERIAL, STANDARDS AND ATTACHMENT TO COMPLY WITH R905.10-R905.10.4.
1/8" = 1'-0"
1Lower Level
1/8" = 1'-0"
2Main Level
1/8" = 1'-0"
3 Upper Level
DRAWN BYDESCRIPTIONPROJECT #PROJECTISSUERE-ISSUEBUILDER18476 KENRICK AVE SUITE 202LAKEVILLE, MN 55044TEL: 952.428.8200EM: Dave@DavidCharlezDesigns.comD A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N Sa
Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)428-8200. David Charlez Design retains rights to all plans and detail shown.8/30/202312:06:05 PM22 Square FootageCalculationsPFC-White Oak Model-CDWhite Oak ModelHandcrafted Custom Homesnick@pfcbuilders.comjack@pfcbuilders.com 612.810.625508.28.2023SMMBerres Ridge8th AdditionBlock 02 Lot 05S Q. F T G. C A L C S.
Name Sq. Ftg.Level Area Type
SPORT COURT (OPT)Not Enclosed Basement Additional Sq. Ftg.
EXERCISE RM 183 SF Basement Additional Sq. Ftg.
STAIRS 117 SF Second Floor Additional Sq. Ftg.
Additional Sq. Ftg.300 SF
LOWER LEVEL 1004 SF Basement Finished Sq. Ftg.
MAIN LEVEL 1488 SF First Floor Finished Sq. Ftg.
UPPER LEVEL 1699 SF Second Floor Finished Sq. Ftg.
Finished Sq. Ftg.4191 SF
PATIO 260 SF Basement Outdoor Sq. Ftg.
DECK 372 SF First Floor Outdoor Sq. Ftg.
FRONT PORCH 120 SF First Floor Outdoor Sq. Ftg.
Outdoor Sq. Ftg.752 SF
GARAGE 857 SF First Floor Unconditioned Sq. Ft.
Unconditioned Sq. Ft.857 SF
MECH 203 SF Basement Unfinished Sq. Ft.
Unfinished Sq. Ft.203 SF
1" = 20'-0"
4 Preliminary Site Plan REVISION SCHEDULENumberDate Issued by
architectural design & draftingbirchhd@hotmail.com
architectural design & draftingbirchhd@hotmail.com
architectural design & draftingbirchhd@hotmail.com
architectural design & draftingbirchhd@hotmail.com
Project Name: Dave Clemens Lakeville Barres Ridge Addition
Address: 19774 Henning Avenue, Lakeville, MN
Summer Outdoor F:88 Summer Indoor F:75 Design Grains:31 Daily Range:Medium
Winter Outdoor F:-8 Winter Indoor F:70 Cooling RH:50 Elevation (Ft):837
Heated square footage:3,251
Cooled square footage:2,275
Heated volume (above grade CF):23,183
Cooled volume (above grade CF):20,475
Exposed wall area (SF):2,858
Heating BTUH:73,393
Cooling BTUH:45,449
CFM:2,110
Sensible cooling:41,793
Latent cooling:3,656
SHR:0.92
Approved ACCA MJ8 Calculations
Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA.
All computed calculations are estimates on building use, weather data, and inputted
values such a R-Values, window types, duct loss, etc. Equipment selections should
meet both the latent and sensible gain as well as building heat loss.
OUTDOOR DESIGN CONDITIONS
Weather station: Minneapolis-St Paul IAP
LOAD CALCULATION TOTALS
HVAC System: Furnace Ducted
Load Calculation
0 20,000 40,000 60,000 80,000
Cooling
Heating
BTUH
HEATING LOADS
SECTION AREA HEAT LOSS
aboveGradeWalls 2,214 16,793
belowGradeWalls 546 2,385
ceilings 2,846 4,440
doors 72 1,460
ducts 0 13,665
floors 2,033 11,441
infiltration 0 6,240
skylights 0 0
windows 572 14,277
winterHumidification 0 2,691
Totals 73,393
COOLING LOADS
SECTION AREA SENSIBLE LATENT
AEDExcursion 0 0 0
aboveGradeWalls 2,214 4,544 0
appliances 0 5,446 358
belowGradeWalls 546 0 0
ceilings 2,846 2,275 0
doors 72 324 0
ducts 0 6,254 1,000
floors 2,033 1,746 0
infiltration 0 541 797
occupants 0 1,380 1,200
plants 0 0 300
skylights 0 0 0
windows 572 19,283 0
winterHumidification 0 0 0
Totals 41,793 3,656
HEATING AND COOLING LOADS
Heating Loads
aboveGradeWalls
22.9%
belowGradeWalls
3.2%
ceilings
6%
ducts
18.6%
floors
15.6%
infiltration
8.5%
windows
19.5%
winterHumidific…
3.7%
Cooling Loads
aboveGradeWalls
10%
appliances
12.8%
ceilings
5%
ducts
16%
floors
3.8%
occupants
5.7%
plants
0.7%
windows
42.4%
This graph represents hourly aggregrate fenestration loads in mid-summer.
This graph represents hourly aggregrate fenestration loads in October.
FENESTRATION LOADS
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
10,000
20,000
30,000
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
10,000
20,000
30,000
BTUH
Construction nr:15B11-0w-x
U Value:0.099
Exposure:E
Area:54
Heating BTUH:417
Cooling BTUH:0
Construction nr:15B11-0w-x
U Value:0.099
Exposure:S
Area:126
Heating BTUH:973
Cooling BTUH:0
Construction nr:12B-0s w
U Value:0.097
Exposure:S
Area:54
Heating BTUH:409
Cooling BTUH:126
Construction nr:12B-0s w
U Value:0.097
Exposure:W
Area:81
Heating BTUH:613
Cooling BTUH:189
Construction nr:12B-0s w
U Value:0.097 Exposure:S
Area:84 Heating BTUH:636
Cooling BTUH:196
Construction nr:12B-0s w
U Value:0.097 Exposure:W
Area:33 Heating BTUH:250
Cooling BTUH:77
Construction nr:12B-0s w
U Value:0.097
Exposure:E
Area:72
Heating BTUH:545
Cooling BTUH:168
Construction nr:12B-0s w
U Value:0.097
Exposure:S
Area:66
Heating BTUH:499
Cooling BTUH:154
Construction nr:12B-0s w
U Value:0.097
Exposure:W
Area:51
Heating BTUH:386
Cooling BTUH:119
Construction nr:15B11-0w-x
U Value:0.099
Exposure:S
Area:16
Heating BTUH:124
Cooling BTUH:0
Construction nr:15B11-0w-x
U Value:0.099
Exposure:W
Area:26
Heating BTUH:201
Cooling BTUH:0
Construction nr:15B11-0w-x
U Value:0.099 Exposure:E
Area:24 Heating BTUH:185
Cooling BTUH:0
Construction nr:15B11-0w-x
U Value:0.099
Exposure:S
Area:14
Heating BTUH:108
Cooling BTUH:0
Construction nr:12B-0s w
U Value:0.097
Exposure:E
Area:63
Heating BTUH:477
Cooling BTUH:147
COMPONENT LOADS
ABOVE GRADE WALLS
System generated wall - W
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
System generated wall - S
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
System generated wall - S
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - E
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - S
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - E
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - W
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - S
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - E
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - S
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
System generated wall - E
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
System generated wall - W
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
System generated wall - S
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
System generated wall - W
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
Construction nr:12B-0s w
U Value:0.097
Exposure:S
Area:123
Heating BTUH:931
Cooling BTUH:288
Construction nr:12B-0s w
U Value:0.097
Exposure:E
Area:72
Heating BTUH:545
Cooling BTUH:168
Construction nr:12B-0s w
U Value:0.097 Exposure:S
Area:66 Heating BTUH:499
Cooling BTUH:154
Construction nr:12B-0s w
U Value:0.097 Exposure:S
Area:63 Heating BTUH:477
Cooling BTUH:147
Construction nr:12B-0s w
U Value:0.097
Exposure:W
Area:63
Heating BTUH:477
Cooling BTUH:147
Construction nr:12B-0s w
U Value:0.097
Exposure:S
Area:114
Heating BTUH:863
Cooling BTUH:266
Construction nr:12B-0s w
U Value:0.097
Exposure:W
Area:105
Heating BTUH:794
Cooling BTUH:245
Construction nr:12B-0s w
U Value:0.097
Exposure:E
Area:15
Heating BTUH:113
Cooling BTUH:35
Construction nr:12B-0s w
U Value:0.097
Exposure:N
Area:117
Heating BTUH:885
Cooling BTUH:274
Construction nr:12B-0s w
U Value:0.097 Exposure:W
Area:84 Heating BTUH:636
Cooling BTUH:196
Construction nr:15B11-0w-x
U Value:0.099
Exposure:W
Area:10
Heating BTUH:77
Cooling BTUH:0
Construction nr:12B-0s w
U Value:0.097
Exposure:N
Area:63
Heating BTUH:477
Cooling BTUH:147
Construction nr:12B-0s w
U Value:0.097
Exposure:E
Area:90
Heating BTUH:681
Cooling BTUH:210
Construction nr:12B-0s w
U Value:0.097
Exposure:S
Area:177
Heating BTUH:1,339
Cooling BTUH:414
Construction nr:12B-0s w
U Value:0.097
Exposure:S
Area:66
Heating BTUH:499
Cooling BTUH:154
ABOVE GRADE WALLS
System generated wall - S
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - W
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - SE
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - S
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - E
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - S
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - E
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - W
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - N
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - W
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - E
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
System generated wall - N
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - W
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - S
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - S
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
Construction nr:12B-0s w
U Value:0.097
Exposure:W
Area:81
Heating BTUH:613
Cooling BTUH:189
Construction nr:12B-0s w
U Value:0.097
Exposure:N
Area:108
Heating BTUH:817
Cooling BTUH:252
Construction nr:12B-0s w
U Value:0.097 Exposure:W
Area:33 Heating BTUH:250
Cooling BTUH:77
Construction nr:15B11-0w-x
U Value:0.056 Area:54 Heating:236
Construction nr:15B11-0w-x
U Value:0.056 Area:126 Heating:550
Construction nr:15B11-0w-x
U Value:0.056 Area:48 Heating:210
Construction nr:15B11-0w-x
U Value:0.056 Area:90 Heating:393
Construction nr:15B11-0w-x
U Value:0.056 Area:72 Heating:314
Construction nr:15B11-0w-x
U Value:0.056 Area:42 Heating:183
Construction nr:15B11-0w-x
U Value:0.056 Area:114 Heating:498
Construction nr:4C
Area:6
Exposure:S
U Value:0.32
SHGC:0.68 Heating BTUH:150
Cooling BTUH:212
Construction nr:4C
Area:12
Exposure:S
U Value:0.32
SHGC:0.68
Heating BTUH:300
Cooling BTUH:424
Construction nr:4C
Area:6
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:150
Cooling BTUH:215
Construction nr:4C
Area:12
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:300
Cooling BTUH:431
Construction nr:4C
Area:36
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:899
Cooling BTUH:1,292
ABOVE GRADE WALLS
System generated wall - E
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - N
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
System generated wall - W
Frame Wall, Wood framing, R-11 cavity
insulation, Stucco or Siding.
BELOW GRADE WALLS
System generated wall - W
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
System generated wall - S
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
System generated wall - S
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
System generated wall - E
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
System generated wall - W
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
System generated wall - S
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
System generated wall - E
8 inch brick, stone or concrete, Wood framing,
R-11 cavity insulation, None board insulation.
WINDOWS
Default small windows for wall id 5079188
Window, NFRC rated, Low-e glass.
Default medium windows for wall id 5079188
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079187
Window, NFRC rated, Low-e glass.
Default medium windows for wall id 5079187
Window, NFRC rated, Low-e glass.
Default large windows for wall id 5079187
Window, NFRC rated, Low-e glass.
Construction nr:4C
Area:12
Exposure:S
U Value:0.32
SHGC:0.68
Heating BTUH:300
Cooling BTUH:424
Construction nr:4C
Area:12
Exposure:S
U Value:0.32
SHGC:0.68 Heating BTUH:300
Cooling BTUH:424
Construction nr:4C
Area:12
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:300
Cooling BTUH:431
Construction nr:4C
Area:12
Exposure:E
U Value:0.32
SHGC:0.68
Heating BTUH:300
Cooling BTUH:372
Construction nr:4C
Area:24
Exposure:E
U Value:0.32
SHGC:0.68
Heating BTUH:599
Cooling BTUH:745
Construction nr:4C
Area:6
Exposure:S
U Value:0.32
SHGC:0.68
Heating BTUH:150
Cooling BTUH:212
Construction nr:4C
Area:12
Exposure:W
U Value:0.32
SHGC:0.68 Heating BTUH:300
Cooling BTUH:431
Construction nr:4C
Area:4
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:100
Cooling BTUH:0
Construction nr:4C
Area:48
Exposure:E
U Value:0.32
SHGC:0.68
Heating BTUH:1,198
Cooling BTUH:1,490
Construction nr:4C
Area:12
Exposure:S
U Value:0.32
SHGC:0.68
Heating BTUH:300
Cooling BTUH:424
Construction nr:4C
Area:12
Exposure:E
U Value:0.32
SHGC:0.68
Heating BTUH:300
Cooling BTUH:372
Construction nr:4C
Area:24
Exposure:E
U Value:0.32
SHGC:0.68
Heating BTUH:599
Cooling BTUH:745
Construction nr:4C
Area:6
Exposure:S
U Value:0.32
SHGC:0.68
Heating BTUH:150
Cooling BTUH:212
Construction nr:4C
Area:6
Exposure:S
U Value:0.32
SHGC:0.68
Heating BTUH:150
Cooling BTUH:212
Construction nr:4C
Area:24
Exposure:S
U Value:0.32
SHGC:0.68 Heating BTUH:599
Cooling BTUH:848
Construction nr:4C
Area:36
Exposure:S
U Value:0.32
SHGC:0.68
Heating BTUH:899
Cooling BTUH:1,272
Construction nr:4C
Area:6
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:150
Cooling BTUH:215
Construction nr:4C
Area:24
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:599
Cooling BTUH:861
Construction nr:4C
Area:36
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:899
Cooling BTUH:1,292
Construction nr:4C
Area:6
Exposure:E
U Value:0.32
SHGC:0.68 Heating BTUH:150
Cooling BTUH:186
Construction nr:4C
Area:12
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:300
Cooling BTUH:431
WINDOWS
Default small windows for wall id 5079692
Window, NFRC rated, Low-e glass.
Default medium windows for wall id 5079692
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079653
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079896
Window, NFRC rated, Low-e glass.
Default medium windows for wall id 5079896
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079907
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079563
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5078817
Window, NFRC rated, Low-e glass.
Default medium windows for wall id 5079365
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079370
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079379
Window, NFRC rated, Low-e glass.
Default medium windows for wall id 5079379
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079380
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5080149
Window, NFRC rated, Low-e glass.
Default medium windows for wall id 5080149
Window, NFRC rated, Low-e glass.
Default large windows for wall id 5080149
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079255
Window, NFRC rated, Low-e glass.
Default medium windows for wall id 5079255
Window, NFRC rated, Low-e glass.
Default large windows for wall id 5079255
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079319
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079808
Window, NFRC rated, Low-e glass.
Construction nr:4C
Area:12
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:300
Cooling BTUH:431
Construction nr:4C
Area:4
Exposure:W
U Value:0.32
SHGC:0.68 Heating BTUH:100
Cooling BTUH:0
Construction nr:4C
Area:6
Exposure:E
U Value:0.32
SHGC:0.68
Heating BTUH:150
Cooling BTUH:186
Construction nr:4C
Area:12
Exposure:E
U Value:0.32
SHGC:0.68
Heating BTUH:300
Cooling BTUH:372
Construction nr:4C
Area:36
Exposure:E
U Value:0.32
SHGC:0.68
Heating BTUH:899
Cooling BTUH:1,117
Construction nr:4C
Area:12
Exposure:S
U Value:0.32
SHGC:0.68
Heating BTUH:300
Cooling BTUH:424
Construction nr:4C
Area:6
Exposure:S
U Value:0.32
SHGC:0.68 Heating BTUH:150
Cooling BTUH:212
Construction nr:4C
Area:6
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:150
Cooling BTUH:215
Construction nr:4C
Area:12
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:300
Cooling BTUH:431
Construction nr:4C
Area:36
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:899
Cooling BTUH:1,292
Construction nr:4C
Area:12
Exposure:W
U Value:0.32
SHGC:0.68
Heating BTUH:300
Cooling BTUH:431
Construction nr:16B-50 ad
U Value:0.02 Area:120 Heating BTUH:187
Cooling BTUH:120
Construction nr:16B-50 ad
U Value:0.02 Area:58 Heating BTUH:90
Cooling BTUH:58
Construction nr:16B-50 ad
U Value:0.02 Area:60 Heating BTUH:94
Cooling BTUH:60
Construction nr:16B-50 ad
U Value:0.02 Area:96 Heating BTUH:150
Cooling BTUH:96
Construction nr:16B-50 ad
U Value:0.02 Area:49 Heating BTUH:76
Cooling BTUH:49
Construction nr:16B-50 ad
U Value:0.02 Area:120 Heating BTUH:187
Cooling BTUH:0
WINDOWS
Default medium windows for wall id 5079808
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5078926
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5080099
Window, NFRC rated, Low-e glass.
Default medium windows for wall id 5080099
Window, NFRC rated, Low-e glass.
Default large windows for wall id 5080099
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5080100
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079476
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079475
Window, NFRC rated, Low-e glass.
Default medium windows for wall id 5079475
Window, NFRC rated, Low-e glass.
Default large windows for wall id 5079475
Window, NFRC rated, Low-e glass.
Default small windows for wall id 5079874
Window, NFRC rated, Low-e glass.
Window cooling BTUHs shown here are daily average values. See AED graphs for details of fenestration loads during the day.
CEILINGS
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
Construction nr:16B-50 ad
U Value:0.02 Area:225 Heating BTUH:351
Cooling BTUH:225
Construction nr:16B-50 ad
U Value:0.02 Area:96 Heating BTUH:150
Cooling BTUH:96
Construction nr:16B-50 ad
U Value:0.02 Area:49 Heating BTUH:76
Cooling BTUH:49
Construction nr:16B-50 ad
U Value:0.02 Area:90 Heating BTUH:140
Cooling BTUH:0
Construction nr:16B-50 ad
U Value:0.02 Area:380 Heating BTUH:593
Cooling BTUH:380
Construction nr:16B-50 ad
U Value:0.02 Area:25 Heating BTUH:39
Cooling BTUH:25
Construction nr:16B-50 ad
U Value:0.02 Area:48 Heating BTUH:75
Cooling BTUH:48
Construction nr:16B-50 ad
U Value:0.02 Area:156 Heating BTUH:243
Cooling BTUH:156
Construction nr:16B-50 ad
U Value:0.02 Area:361 Heating BTUH:563
Cooling BTUH:0
Construction nr:16B-50 ad
U Value:0.02 Area:63 Heating BTUH:98
Cooling BTUH:63
Construction nr:16B-50 ad
U Value:0.02 Area:336 Heating BTUH:524
Cooling BTUH:336
Construction nr:16B-50 ad
U Value:0.02 Area:120 Heating BTUH:187
Cooling BTUH:120
Construction nr:16B-50 ad
U Value:0.02 Area:144 Heating BTUH:225
Cooling BTUH:144
Construction nr:16B-50 ad
U Value:0.02 Area:25 Heating BTUH:39
Cooling BTUH:25
Construction nr:16B-50 ad
U Value:0.02 Area:225 Heating BTUH:351
Cooling BTUH:225
CEILINGS
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
System generated ceiling.
Ceiling under attic or attic knee wall, Asphalt
shingles, Dark, R-50.
Construction nr:11
U Value:0.26 Area:24
Exposure:E Heating BTUH:487
Cooling BTUH:162
Construction nr:11
U Value:0.26
Area:24
Exposure:E
Heating BTUH:487
Cooling BTUH:162
Construction nr:11
U Value:0.26
Area:24
Exposure:W
Heating BTUH:487
Cooling BTUH:0
Construction nr:21A
Area:189
Heating U Value:0.027
Cooling U Value:0
Heating BTUH:398
Cooling BTUH:0
F Value:N/A
Construction nr:19A-0cp
Area:58 Heating U Value:0.295
Cooling U Value:0.295
Heating BTUH:515
Cooling BTUH:96
F Value:N/A
Construction nr:21A
Area:120
Heating U Value:0.027
Cooling U Value:0
Heating BTUH:253
Cooling BTUH:0
F Value:N/A
Construction nr:21A
Area:84
Heating U Value:0.027
Cooling U Value:0
Heating BTUH:177
Cooling BTUH:0
F Value:N/A
Construction nr:21A
Area:132
Heating U Value:0.027
Cooling U Value:0
Heating BTUH:278
Cooling BTUH:0
F Value:N/A
Construction nr:19A-0cp
Area:225
Heating U Value:0.295
Cooling U Value:0.295
Heating BTUH:1,998
Cooling BTUH:372
F Value:N/A
Construction nr:19A-0cp
Area:96
Heating U Value:0.295
Cooling U Value:0.295
Heating BTUH:852
Cooling BTUH:159
F Value:N/A
Construction nr:21A
Area:90
Heating U Value:0.027
Cooling U Value:0
Heating BTUH:190
Cooling BTUH:0
F Value:N/A
Construction nr:19A-0cp
Area:380
Heating U Value:0.295
Cooling U Value:0.295
Heating BTUH:3,374
Cooling BTUH:628
F Value:N/A
Construction nr:19A-0cp
Area:25
Heating U Value:0.295
Cooling U Value:0.295
Heating BTUH:222
Cooling BTUH:41
F Value:N/A
SKYLIGHTSSKYLIGHTS
There are no components for this section.
Skylight cooling BTUHs shown here are daily average values. See AED graphs for details of fenestration loads during the day.
DOORS
Default doors for wall id 5079365
Wood Door, Solid Core with Wood Storm.
Default doors for wall id 5079319
Wood Door, Solid Core with Wood Storm.
Default doors for wall id 5078926
Wood Door, Solid Core with Wood Storm.
FLOORS
System generated floor.
Basement floor, no floor insulation.
System generated floor.
Floor over enclosed unconditioned crawl space
or basement, no floor insulation, Carpet or
hardwood.
System generated floor.
Basement floor, no floor insulation.
System generated floor.
Basement floor, no floor insulation.
System generated floor.
Basement floor, no floor insulation.
System generated floor.
Floor over enclosed unconditioned crawl space
or basement, no floor insulation, Carpet or
hardwood.
System generated floor.
Floor over enclosed unconditioned crawl space
or basement, no floor insulation, Carpet or
hardwood.
System generated floor.
Basement floor, no floor insulation.
System generated floor.
Floor over enclosed unconditioned crawl space
or basement, no floor insulation, Carpet or
hardwood.
System generated floor.
Floor over enclosed unconditioned crawl space
or basement, no floor insulation, Carpet or
hardwood.
Construction nr:19A-0cp
Area:48
Heating U Value:0.295
Cooling U Value:0.295
Heating BTUH:426
Cooling BTUH:79
F Value:N/A
Construction nr:21A
Area:361
Heating U Value:0.027
Cooling U Value:0
Heating BTUH:760
Cooling BTUH:0
F Value:N/A
Construction nr:19A-0cp
Area:225 Heating U Value:0.295
Cooling U Value:0.295
Heating BTUH:1,998
Cooling BTUH:372
F Value:N/A
EHLF:0.111
ESGF:0.061
ELG:827
Heating BTUH:6,633
Sensible BTUH:2,176
Latent BTUH:827
EHLF:0.118
ESGF:0.115
ELG:173
Heating BTUH:7,032
Sensible BTUH:4,078
Latent BTUH:173
Leakage Category:Semi-Tight NCFM Heating:97
NCFM Cooling:50
Heating BTUH:6,240
Sensible BTUH:541
Latent BTUH:797
Desired Indoor RH:40 Gallons Per Day:7.3 Heating BTUH:2,691
Nr. Occupants:6 Sensible BTUH:1,380 Latent BTUH:1,200
Nr. Occupants:6 Sensible BTUH:0 Latent BTUH:0
Vented clothes dryer Quantity:1 Sensible BTUH:0
Latent BTUH:0
Clothes washing machine Quantity:1 Sensible BTUH:0
Latent BTUH:0
Refrigerator or Freezer - 12CuFt Quantity:1 Sensible BTUH:0
Latent BTUH:0
Color television Quantity:1 Sensible BTUH:683
Latent BTUH:0
Computer and monitor Quantity:1 Sensible BTUH:538
Latent BTUH:0
Light Fixture - 100W Quantity:3 Sensible BTUH:1,023
Latent BTUH:0
Color television Quantity:1 Sensible BTUH:0
Latent BTUH:0
FLOORS
System generated floor.
Floor over enclosed unconditioned crawl space
or basement, no floor insulation, Carpet or
hardwood.
System generated floor.
Basement floor, no floor insulation.
System generated floor.
Floor over enclosed unconditioned crawl space
or basement, no floor insulation, Carpet or
hardwood.
VENTILATION
There are no components for this section.
HOT WATER PIPING
There are no components for this section.
DUCTS
System generated ducts (below conditioned space)
Unconditioned Basement - Radial
System generated ducts (above conditioned space)
Attic - Radial
INFILTRATION
BLOWER MOTOR
There are no components for this section.
WINTER HUMIDIFICATION
OCCUPANTS
APPLIANCES
Computer and monitor Quantity:1 Sensible BTUH:0
Latent BTUH:0
Light Fixture - 100W Quantity:3 Sensible BTUH:0
Latent BTUH:0
Vented clothes dryer Quantity:1 Sensible BTUH:427
Latent BTUH:0
Clothes washing machine Quantity:1 Sensible BTUH:51
Latent BTUH:0
Refrigerator or Freezer - 12CuFt Quantity:1 Sensible BTUH:700
Latent BTUH:0
Range with hood and exhaust to outdoors Quantity:1 Sensible BTUH:0
Latent BTUH:0
Dishwasher Quantity:1 Sensible BTUH:1,024
Latent BTUH:358
Refrigerator or Freezer - 16CuFt Quantity:1 Sensible BTUH:1,000
Latent BTUH:0
Plant Size:medium Quantity:5 Latent BTUH:100
Plant Size:large Quantity:5 Latent BTUH:150
Plant Size:medium Quantity:5 Latent BTUH:0
Plant Size:large Quantity:5 Latent BTUH:0
Plant Size:small Quantity:5 Latent BTUH:50
APPLIANCES
PLANTS
Heated square footage:120
Cooled square footage:0
Heated volume (above grade CF):240
Cooled volume (above grade CF):0
Exposed wall area (SF):46
Total Cooling BTUH:0
Total Heating BTUH:1,926
CFM:31
ROOM DETAIL
Room name: Bedroom 5
Load Calculation
0 500 1,000 1,500 2,000
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 19-1
0
1
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 19-1
0
1
BTUH
Heated square footage:90
Cooled square footage:0
Heated volume (above grade CF):180
Cooled volume (above grade CF):0
Exposed wall area (SF):0
Total Cooling BTUH:0
Total Heating BTUH:405
CFM:6
ROOM DETAIL
Room name: Bath Lower Level
Load Calculation
0 100 200 300 400 500
Cooling
Heating
BTUH
Heated square footage:361
Cooled square footage:0
Heated volume (above grade CF):722
Cooled volume (above grade CF):0
Exposed wall area (SF):38
Total Cooling BTUH:0
Total Heating BTUH:3,156
CFM:52
ROOM DETAIL
Room name: Family Room
Load Calculation
0 1,000 2,000 3,000 4,000
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 19-1
0
1
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 19-1
0
1
BTUH
Heated square footage:132
Cooled square footage:0
Heated volume (above grade CF):264
Cooled volume (above grade CF):0
Exposed wall area (SF):0
Total Cooling BTUH:0
Total Heating BTUH:342
CFM:5
ROOM DETAIL
Room name: Wet Bar
Load Calculation
0 100 200 300 400
Cooling
Heating
BTUH
Heated square footage:84
Cooled square footage:0
Heated volume (above grade CF):168
Cooled volume (above grade CF):0
Exposed wall area (SF):38
Total Cooling BTUH:0
Total Heating BTUH:1,292
CFM:21
ROOM DETAIL
Room name: Mechanical Room
Load Calculation
0 500 1,000 1,500
Cooling
Heating
BTUH
Heated square footage:189
Cooled square footage:0
Heated volume (above grade CF):1,134
Cooled volume (above grade CF):0
Exposed wall area (SF):180
Total Cooling BTUH:0
Total Heating BTUH:3,646
CFM:60
ROOM DETAIL
Room name: Stairwell
Load Calculation
0 1,000 2,000 3,000 4,000
Cooling
Heating
BTUH
Heated square footage:120
Cooled square footage:120
Heated volume (above grade CF):1,080
Cooled volume (above grade CF):1,080
Exposed wall area (SF):207
Total Cooling BTUH:4,779
Total Heating BTUH:4,249
CFM:238
ROOM DETAIL
Room name: Dining Room
Load Calculation
0 1,000 2,000 3,000 4,000 5,000
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
2,000
4,000
6,000
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
2,000
4,000
BTUH
Heated square footage:380
Cooled square footage:380
Heated volume (above grade CF):3,420
Cooled volume (above grade CF):3,420
Exposed wall area (SF):351
Total Cooling BTUH:13,933
Total Heating BTUH:11,901
CFM:625
ROOM DETAIL
Room name: Great Room
Load Calculation
0 5,000 10,000 15,000
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
2,500
5,000
7,500
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
2,500
5,000
7,500
BTUH
Heated square footage:225
Cooled square footage:225
Heated volume (above grade CF):2,025
Cooled volume (above grade CF):2,025
Exposed wall area (SF):0
Total Cooling BTUH:3,490
Total Heating BTUH:2,886
CFM:155
ROOM DETAIL
Room name: Kitchen
Load Calculation
0 1,000 2,000 3,000 4,000
Cooling
Heating
BTUH
Heated square footage:48
Cooled square footage:48
Heated volume (above grade CF):432
Cooled volume (above grade CF):432
Exposed wall area (SF):0
Total Cooling BTUH:150
Total Heating BTUH:616
CFM:7
ROOM DETAIL
Room name: Pantry
Load Calculation
0 200 400 600 800
Cooling
Heating
BTUH
Heated square footage:58
Cooled square footage:58
Heated volume (above grade CF):522
Cooled volume (above grade CF):522
Exposed wall area (SF):0
Total Cooling BTUH:181
Total Heating BTUH:744
CFM:9
ROOM DETAIL
Room name: Powder Room
Load Calculation
0 200 400 600 800
Cooling
Heating
BTUH
Heated square footage:25
Cooled square footage:25
Heated volume (above grade CF):225
Cooled volume (above grade CF):225
Exposed wall area (SF):45
Total Cooling BTUH:720
Total Heating BTUH:1,363
CFM:35
ROOM DETAIL
Room name: Mud Room
Load Calculation
0 500 1,000 1,500
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
200
400
600
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
100
200
300
BTUH
Heated square footage:225
Cooled square footage:225
Heated volume (above grade CF):2,025
Cooled volume (above grade CF):2,025
Exposed wall area (SF):270
Total Cooling BTUH:4,786
Total Heating BTUH:7,778
CFM:237
ROOM DETAIL
Room name: Foyer
Load Calculation
0 2,000 4,000 6,000 8,000
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
2,000
4,000
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
1,000
2,000
3,000
BTUH
Heated square footage:96
Cooled square footage:96
Heated volume (above grade CF):864
Cooled volume (above grade CF):864
Exposed wall area (SF):180
Total Cooling BTUH:3,164
Total Heating BTUH:4,286
CFM:157
ROOM DETAIL
Room name: Office
Load Calculation
0 1,000 2,000 3,000 4,000 5,000
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
1,000
2,000
3,000
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
1,000
2,000
BTUH
Heated square footage:120
Cooled square footage:120
Heated volume (above grade CF):1,080
Cooled volume (above grade CF):1,080
Exposed wall area (SF):207
Total Cooling BTUH:4,529
Total Heating BTUH:3,992
CFM:225
ROOM DETAIL
Room name: Owners Suite
Load Calculation
0 1,000 2,000 3,000 4,000 5,000
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
2,000
4,000
6,000
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
2,000
4,000
BTUH
Heated square footage:144
Cooled square footage:144
Heated volume (above grade CF):1,296
Cooled volume (above grade CF):1,296
Exposed wall area (SF):108
Total Cooling BTUH:520
Total Heating BTUH:1,570
CFM:24
ROOM DETAIL
Room name: Owner WIC
Load Calculation
0 500 1,000 1,500 2,000
Cooling
Heating
BTUH
Heated square footage:49
Cooled square footage:49
Heated volume (above grade CF):441
Cooled volume (above grade CF):441
Exposed wall area (SF):63
Total Cooling BTUH:1,060
Total Heating BTUH:1,105
CFM:52
ROOM DETAIL
Room name: Owners Bath
Load Calculation
0 250 500 750 1,000 1,250
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
500
1,000
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
250
500
750
BTUH
Heated square footage:60
Cooled square footage:60
Heated volume (above grade CF):540
Cooled volume (above grade CF):540
Exposed wall area (SF):153
Total Cooling BTUH:2,117
Total Heating BTUH:2,717
CFM:104
ROOM DETAIL
Room name: Bedroom 2
Load Calculation
0 1,000 2,000 3,000
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
1,000
2,000
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
1,000
2,000
3,000
BTUH
Heated square footage:49
Cooled square footage:49
Heated volume (above grade CF):441
Cooled volume (above grade CF):441
Exposed wall area (SF):126
Total Cooling BTUH:467
Total Heating BTUH:1,603
CFM:21
ROOM DETAIL
Room name: Bedroom 2 Bath
Load Calculation
0 500 1,000 1,500 2,000
Cooling
Heating
BTUH
Heated square footage:63
Cooled square footage:63
Heated volume (above grade CF):567
Cooled volume (above grade CF):567
Exposed wall area (SF):63
Total Cooling BTUH:1,664
Total Heating BTUH:876
CFM:83
ROOM DETAIL
Room name: Laundry
Load Calculation
0 500 1,000 1,500 2,000
Cooling
Heating
BTUH
Heated square footage:156
Cooled square footage:156
Heated volume (above grade CF):1,404
Cooled volume (above grade CF):1,404
Exposed wall area (SF):225
Total Cooling BTUH:2,511
Total Heating BTUH:3,508
CFM:123
ROOM DETAIL
Room name: Bedroom 4
Load Calculation
0 1,000 2,000 3,000 4,000
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
1,000
2,000
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
500
1,000
1,500
BTUH
Heated square footage:0
Cooled square footage:0
Heated volume (above grade CF):0
Cooled volume (above grade CF):0
Exposed wall area (SF):0
Total Cooling BTUH:0
Total Heating BTUH:0
CFM:
ROOM DETAIL
Room name: J & J Bath
Load Calculation
-1.0 -0.5 0.0 0.5 1.0
Cooling
Heating
BTUH
Heated square footage:25
Cooled square footage:25
Heated volume (above grade CF):225
Cooled volume (above grade CF):225
Exposed wall area (SF):45
Total Cooling BTUH:974
Total Heating BTUH:844
CFM:48
ROOM DETAIL
Room name: WIC 4
Load Calculation
0 200 400 600 800 1,000
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
500
1,000
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
250
500
750
BTUH
Heated square footage:96
Cooled square footage:96
Heated volume (above grade CF):864
Cooled volume (above grade CF):864
Exposed wall area (SF):180
Total Cooling BTUH:2,978
Total Heating BTUH:3,238
CFM:147
ROOM DETAIL
Room name: Bedroom 3
Load Calculation
0 1,000 2,000 3,000 4,000
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
1,000
2,000
3,000
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
1,000
2,000
BTUH
Heated square footage:336
Cooled square footage:336
Heated volume (above grade CF):3,024
Cooled volume (above grade CF):3,024
Exposed wall area (SF):333
Total Cooling BTUH:4,924
Total Heating BTUH:6,044
CFM:244
ROOM DETAIL
Room name: Loft
Load Calculation
0 2,000 4,000 6,000 8,000
Cooling
Heating
BTUH
AED Graph (mid-summer)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
2,000
4,000
BTUHAED graph (fall)
BTUH Average Average * 1.3
8 9 10 11 12 13 14 15 16 17 18 190
1,000
2,000
3,000
BTUH
19558