Loading...
HomeMy WebLinkAboutLA218977 - 8362 186th St W Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND Secure door closed until deck is constructed with a separate permit. Concept Approval ONLY Subject to Field Inspection Inspector Date 2015 MN Bldg Code 10/06/2023jnuetzman UFER Ground -Provide 20' Rebar in footing and stub up near electrical service panel. FAN -Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). Smoke CO Smoke Smoke Smoke CO Distinctive Design Build HVAC Load Calculations for Distinctive Design Build 8362 186th St W Lakeville,mn Prepared By: Randy Andrews Lofgren Heating 5708 Upper 147th Street West Apple Vallley, MN 55124 Monday, September 18, 2023 Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 2 Project Report General Project Information Project Title:Distinctive Design Build Project Date:Monday, September 18, 2023 Client Name:Distinctive Design Build Client Address:8362 186th St W Client City:Lakeville,mn Company Name:Lofgren Heating Company Representative:Randy Andrews Company Address:5708 Upper 147th Street West Company City:Apple Vallley, MN 55124 Company E-Mail Address:rrandrews@lofgrenheating-ac.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces North Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Elevation Sensible Adj. Factor:1.000 Elevation Total Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Elevation Heating Adj. Factor:1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29 Check Figures Total Building Supply CFM:1,018 CFM Per Square ft.:0.303 Square ft. of Room Area:3,354 Square ft. Per Ton:1,476 Volume (ft³) of Cond. Space:30,186 Building Loads Total Heating Required Including Ventilation Air:44,251 Btuh 44.251 MBH Total Sensible Gain:22,164 Btuh 81 % Total Latent Gain:5,098 Btuh 19 % Total Cooling Required Including Ventilation Air:27,262 Btuh 2.27 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 3 Miscellaneous Report System 1 Whole House Input Data Outdoor Dry Bulb Outdoor Wet Bulb Outdoor Rel.Hum Indoor Rel.Hum Indoor Dry Bulb Grains Difference Winter:-15 -15.33 80%n/a 72 n/a Summer:88 72 47%50%75 29.27 Duct Sizing Inputs Main Trunk Runouts Calculate:Yes Yes Use Schedule:No No Roughness Factor:0.00300 0.01000 Pressure Drop:0.1000 in.wg./100 ft.0.1000 in.wg./100 ft. Minimum Velocity:650 ft./min 450 ft./min Maximum Velocity:900 ft./min 750 ft./min Minimum Height:8 in.6 in. Maximum Height:10 in.6 in. Outside Air Data Winter Summer Infiltration Specified:0.250 AC/hr 0.130 AC/hr 84 CFM 44 CFM Infiltration Actual:0.250 AC/hr 0.130 AC/hr Above Grade Volume:Cu.ft.Cu.ft.X 20,203 X 20,203 5,051 Cu.ft./hr 2,626 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration:84 CFM 44 CFM Total Building Ventilation:140 CFM 70 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 19.31 = (0.68 X 0.970 X 29.27 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified:0.250 AC/hr (84 CFM), Construction: Unknown Summer Infiltration Specified:0.130 AC/hr (44 CFM), Construction: Unknown C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 4 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.27 1,476 3,354 22,164 5,098 27,262 44,251 800 1,018 1,018 System 1 Yes 2.27 1,476 3,354 22,164 5,098 27,262 44,251 800 1,018 1,018 18x10 Ventilation 437 1,352 1,789 5,850 Zone 1 3,354 21,727 3,746 25,473 38,401 800 1,018 1,018 18x10 1-Upper Level 1,677 19,809 2,675 22,484 27,766 578 928 928 11--6 2-Lower Level 1,677 1,918 1,071 2,989 10,635 221 90 90 1--6 C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 5 Duct Size Preview Room or Duct Name Minimum Velocity Maximum Velocity Rough. Factor Design L/100 Actual L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size System 1 Supply Runouts Zone 1 1-Upper Level 450 750 0 0.1 0.1 429.7 578 928 928 11--6 2-Lower Level 450 750 0 0.1 0.1 457.6 221 90 90 1--6 Other Ducts Supply Main Trunk 650 900 0 0.1 0.1 814.3 800 1,018 1,018 18x10 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:800 Cooling Flow:1018 C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 6 System 1 - Whole House - Adequate Exposure Diversity Test Test For Adequate Exposure Diversity Average Glass Sensible Gain Over 12 Hours 1.3 x Average Glass Gain Hourly Glass Gain Hourly Total Net GainHeat Gain, Btuh23.5% Diff. from Avg. 0 10,000 20,000 30,000 40,000 8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pm AED Calculation Summary --- SYSTEM HAS ADEQUATE EXPOSURE DIVERSITY. --- System is on N, E, S, W rosette. Peak load exceeds 12-hour average load by 23.5%. AED Excursion (amount by which peak exceeds 1.3 x average): 0 Btuh Definition: A system has adequate exposure diversity if the peak-hour glass load for the entire conditioned space does not exceed the average glass load for the entire conditioned space by more than 30 percent. C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 7 System 1 - Whole House - Psychrometric Chart ZC Zone (Room) Condition OC Outdoor Condition LC Leaving Coil Condition EC Entering Coil Condition SD Supply Duct Temperature Rise DTF Draw Through Fan Sensible Gain HRV Heat Recovery Ventilator C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 8 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 402 11,191 0 10,273 10,273 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 1473 8,329 0 1,274 1,274 15B0-10sf-10: Wall-Basement, , R-10 board insulation to floor, no interior finish, 10' floor depth 756 3,222 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1677 2,918 0 1,610 1,610 21A-24-c: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, carpet covering, shortest side of floor slab is 24' wide 1677 3,647 0 0 0 Subtotals for structure:30,585 0 13,509 13,509 People:7 1,400 1,610 3,010 Equipment:1,500 6,000 7,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 84, Summer CFM: 44 7,816 846 608 1,454 Ventilation: Winter CFM: 140, Summer CFM: 70 5,850 1,352 437 1,789 Total Building Load Totals:44,251 5,098 22,164 27,262 Check Figures Total Building Supply CFM:1,018 CFM Per Square ft.:0.303 Square ft. of Room Area:3,354 Square ft. Per Ton:1,476 Volume (ft³) of Cond. Space:30,186 Building Loads Total Heating Required Including Ventilation Air:44,251 Btuh 44.251 MBH Total Sensible Gain:22,164 Btuh 81 % Total Latent Gain:5,098 Btuh 19 % Total Cooling Required Including Ventilation Air:27,262 Btuh 2.27 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 9 Building Pie Chart Building Loss 44,251 Btuh Floor 8% Roof 7% Wall 26% Glass 25% Door 3% Infiltration 18% Ventilation 13% Building Gain 27,262 Btuh Roof 6% Wall 5% Glass 38% Door 1%People 11% Equipment 28% Infiltration 5% Ventilation 7% C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 10 Building Bar Graph Building Loss 44,251 Btuh 0 5,000 10,000 15,000 Floor 8%Wall 26%Door 3%Ventilation 13% Roof 7%Glass 25%Infiltration 18% Building Gain 27,262 Btuh 0 5,000 10,000 15,000 Roof 6%Glass 38%People 11%Infiltration 5% Wall 5%Door 1%Equipment 28%Ventilation 7% C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 11 System 1 Whole House Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 402 11,191 0 10,273 10,273 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 1473 8,329 0 1,274 1,274 15B0-10sf-10: Wall-Basement, , R-10 board insulation to floor, no interior finish, 10' floor depth 756 3,222 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1677 2,918 0 1,610 1,610 21A-24-c: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, carpet covering, shortest side of floor slab is 24' wide 1677 3,647 0 0 0 Subtotals for structure:30,585 0 13,509 13,509 People:7 1,400 1,610 3,010 Equipment:1,500 6,000 7,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 84, Summer CFM: 44 7,816 846 608 1,454 Ventilation: Winter CFM: 140, Summer CFM: 70 5,850 1,352 437 1,789 System 1 Whole House Load Totals:44,251 5,098 22,164 27,262 Check Figures Supply CFM:1,018 CFM Per Square ft.:0.303 Square ft. of Room Area:3,354 Square ft. Per Ton:1,476 Volume (ft³) of Cond. Space:30,186 System Loads Total Heating Required Including Ventilation Air:44,251 Btuh 44.251 MBH Total Sensible Gain:22,164 Btuh 81 % Total Latent Gain:5,098 Btuh 19 % Total Cooling Required Including Ventilation Air:27,262 Btuh 2.27 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 12 System 1 Whole House Pie Chart System 1 Whole House Loss 44,251 Btuh Floor 8% Roof 7% Wall 26% Glass 25% Door 3% Infiltration 18% Ventilation 13% System 1 Whole House Gain 27,262 Btuh Roof 6% Wall 5% Glass 38% Door 1%People 11% Equipment 28% Infiltration 5% Ventilation 7% C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 13 System 1 Whole House Bar Graph System 1 Whole House Loss 44,251 Btuh 0 5,000 10,000 15,000 Floor 8%Wall 26%Door 3%Ventilation 13% Roof 7%Glass 25%Infiltration 18% System 1 Whole House Gain 27,262 Btuh 0 5,000 10,000 15,000 Roof 6%Glass 38%People 11%Infiltration 5% Wall 5%Door 1%Equipment 28%Ventilation 7% C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 14 System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms) Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain 4A-1a-o: Glazing-Double pane low-e (e = 0.20 or less), operable window, e=0.20 on surface 2, wood with metal clad frame, u-value 0.32, SHGC 0.33 402 11,191 0 10,273 10,273 11N: Door-Metal - Polystyrene Core 42 1,278 0 352 352 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs 1473 8,329 0 1,274 1,274 15B0-10sf-10: Wall-Basement, , R-10 board insulation to floor, no interior finish, 10' floor depth 756 3,222 0 0 0 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation 1677 2,918 0 1,610 1,610 21A-24-c: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, carpet covering, shortest side of floor slab is 24' wide 1677 3,647 0 0 0 Subtotals for structure:30,585 0 13,509 13,509 People:7 1,400 1,610 3,010 Equipment:1,500 6,000 7,500 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 84, Summer CFM: 44 7,816 846 608 1,454 System 1, Zone 1 Load Totals:38,401 3,746 21,727 25,473 Check Figures Supply CFM:1,018 CFM Per Square ft.:0.303 Square ft. of Room Area:3,354 Square ft. Per Ton:1,580 Volume (ft³) of Cond. Space:30,186 Zone Loads Total Heating Required:38,401 Btuh 38.401 MBH Total Sensible Gain:21,727 Btuh 85 % Total Latent Gain:3,746 Btuh 15 % Total Cooling Required:25,473 Btuh 2.12 Tons (Based On Sensible + Latent) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 15 System 1, Zone 1 Pie Chart System 1, Zone 1 Loss 38,401 Btuh Floor 9% Roof 8% Wall 30% Glass 29% Door 3% Infiltration 20% System 1, Zone 1 Gain 25,473 Btuh Roof 6% Wall 5% Glass 40% Door 1% People 12% Equipment 29% Infiltration 6% C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 16 System 1, Zone 1 Bar Graph System 1, Zone 1 Loss 38,401 Btuh 0 5,000 10,000 15,000 Floor 9%Wall 30%Door 3% Roof 8%Glass 29%Infiltration 20% System 1, Zone 1 Gain 25,473 Btuh 0 5,000 10,000 15,000 Roof 6%Glass 40%People 12%Infiltration 6% Wall 5%Door 1%Equipment 29% C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 17 Detailed Room Loads - Room 1 - Upper Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,677.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,677.0 sq.ft.Supply Air:928 CFM Ceiling Height:9.0 ft.Supply Air Changes:3.7 AC/hr Volume:15,093.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:11 Actual Winter Vent.:101 CFM Runout Air:84 CFM Percent of Supply.:11 % Runout Duct Size:6 in.Actual Summer Vent.:64 CFM Runout Air Velocity:430 ft./min.Percent of Supply:7 % Runout Air Velocity:430 ft./min.Actual Winter Infil.:67 CFM Actual Loss:0.116 in.wg./100 ft.Actual Summer Infil.:35 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain N -Wall-12F-0sw 43 X 9 269 0.065 5.7 1,521 0.9 0 233 S -Wall-12F-0sw 43 X 9 265 0.065 5.7 1,499 0.9 0 229 E -Wall-12F-0sw 42 X 9 286 0.065 5.7 1,617 0.9 0 247 W -Wall-12F-0sw 42 X 9 266 0.065 5.7 1,504 0.9 0 230 N -Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176 N -Door-11N 3 X 7 21 0.350 30.5 639 8.4 0 176 N -Gls-4A-1a-o shgc-0.33 100%S 76 0.320 27.8 2,116 10.4 0 791 S -Gls-4A-1a-o shgc-0.33 0%S 122 0.320 27.8 3,396 19.2 0 2,340 E -Gls-4A-1a-o shgc-0.33 0%S 92 0.320 27.8 2,561 35.0 0 3,221 W -Gls-4A-1a-o shgc-0.33 0%S 112 0.320 27.8 3,118 35.0 0 3,921 UP-Ceil-16B-50 1677 X 1 1677 0.020 1.7 2,918 1.0 0 1,610 Subtotals for Structure:21,528 0 13,174 Infil.: Win.: 67.2, Sum.: 34.9 1,530 4.077 6,238 0.317 675 485 People: 200 lat/per, 230 sen/per:5 1,000 1,150 Equipment:1,000 5,000 Room Totals:27,766 2,675 19,809 C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 18 Detailed Room Loads - Room 2 - Lower Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:1,677.0 ft.System Number:1 Room Width:1.0 ft.Zone Number:1 Area:1,677.0 sq.ft.Supply Air:90 CFM Ceiling Height:9.0 ft.Supply Air Changes:0.4 AC/hr Volume:15,093.0 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:1 Actual Winter Vent.:39 CFM Runout Air:90 CFM Percent of Supply.:43 % Runout Duct Size:6 in.Actual Summer Vent.:6 CFM Runout Air Velocity:458 ft./min.Percent of Supply:7 % Runout Air Velocity:458 ft./min.Actual Winter Infil.:17 CFM Actual Loss:0.131 in.wg./100 ft.Actual Summer Infil.:9 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain N -Wall-12F-0sw 43 X 9 387 0.065 5.7 2,188 0.9 0 335 E -Wall-15B0-10sf-10 42 X 9 378 0.049 4.3 1,611 0.0 0 0 W -Wall-15B0-10sf-10 42 X 9 378 0.049 4.3 1,611 0.0 0 0 Floor-21A-24 1 X 1677 1677 0.025 2.2 3,647 0.0 0 0 Subtotals for Structure:9,057 0 335 Infil.: Win.: 17.0, Sum.: 8.8 387 4.078 1,578 0.318 171 123 People: 200 lat/per, 230 sen/per:2 400 460 Equipment:500 1,000 Room Totals:10,635 1,071 1,918 C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 19 Room Cooling and Heating Loads Bar Graphs Cooling Heating Btuh Lower Level Upper Level 0 5,000 10,000 15,000 20,000 25,000 30,000 C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 20 Room Cooling Loads Bar Graphs Sensible Latent Btuh Lower Level Upper Level 0 5,000 10,000 15,000 20,000 25,000 C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Lofgren Htg. & A/C Distinctive Design Build Farmington, MN 55024 Page 21 System 1 Room Load Summary No Room Name Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM ---Zone 1--- 1 Upper Level 1,677 27,766 578 11-6 430 19,809 2,675 928 928 2 Lower Level 1,677 10,635 221 1-6 458 1,918 1,071 90 90 Ventilation 5,850 437 1,352 System 1 total 3,354 44,251 800 22,164 5,098 1,018 1,018 System 1 Main Trunk Size:18x10 in. Velocity:814 ft./min Loss per 100 ft.:0.104 in.wg Cooling System Summary Cooling Tons Sensible/Latent Split Sensible Btuh Latent Btuh Total Btuh Net Required:2.27 81% / 19%22,164 5,098 27,262 Actual:1.00 77% / 23%9,240 2,760 12,000 Equipment Data Heating System Cooling System Type:Natural Gas Furnace Standard Air Conditioner Model:QC-F38-E78-G QC-C12 Indoor Model:S12 Brand:Quikcool FE Series Quikcool AS Series Description:Hi Efficiency Furnace Standard Efficiency Air Condit Efficiency:78.3 AFUE 12.4 SEER Sound:8.1 bels Capacity:38,000 Btuh 12,000 Btuh Sensible Capacity:n/a 9,240 Btuh Latent Capacity:n/a 2,760 Btuh C:\ ...\8362 186TH ST LAKEVILLE 09182023.rhv Monday, September 18, 2023, 12:01 PM Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 9/27/23 X PM