Loading...
HomeMy WebLinkAboutLA219119 THE FOLLOWING INFORMATION MUST BE INCLUDED WITH YOUR APPLICATION:  Payment for amount of permit.  For freestanding/monument/pylon sign - a site plan with setback from property line dimensions and art work with dimensions of sign, and engineered design for footings and foundation.  For wall sign, art work with dimensions of sign and drawings of building façade showing location of sign.  If illuminated or if electrical services are needed, a separate electrical permit is required.  If leased space, need to include a letter of approval from the property owner. SIGN LOCATION Name__________________________________________________________________________________ Address________________________________________________________________________________ City ____________________________________State__________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ PROPERTY OWNER Name__________________________________________________________________________________ Address________________________________________________________________________________ City ____________________________________State__________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ SIGN CONTRACTOR Company Name _________________________________________________________________________ Address________________________________________________________________________________ City ___________________________________ State___________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ SIGN DESCRIPTION  Electronic ($100 per sign plus completion of electronic sign license, see Page 2)  Permanent ($75 per sign)  Temporary ($50 per event, up to 60 days per year. Max of one temp sign displayed at a time.) Temporary sign displayed dates: START DATE ________________________ END DATE ________________________ Sign Type and Dimensions  Wall Sign: Width ____________ Height: _______________ Square feet _____________________________  Freestanding: Face Width_________ Height____________ Sq. ft__________ Overall Sign Height _________ Setbacks: Front _________ Side ____________  Temporary Width___________ Height ______________ Sign Square Feet______________________ Display location _______________________ Illuminated Sign:  Internally illuminated  Externally illuminated  Not illuminated Type of Work:  New Sign  Replacement Sign  Alter Existing Sign Changeable Copy:  No Changeable Copy  Manual Changeable Copy  Electronic Changeable Copy (Electronic sign will require annual license review & renewal, see Page 2) Applicant Signature: ____________________________________________Date:_________________ Applicant Printed Name: _______________________________________________________________ SIGN PERMIT APPLICATION & ELECTRONIC SIGN LICENSE City of Lakeville – Planning Department 20195 Holyoke Avenue - Lakeville, MN 55044 952.985.4420 - www.lakevillemn.gov Goodwill 11578 207th St W Lakeville MN 55044 Goodwill Easter Seals 553 Fairview Ave N St. Paul MN 55104 Kristen Kropp 651-895-6543 klengels@gesmn.org Topline Advertising, Inc. 16307 Aberdeen St NE Ham Lake MN 55304 Katie Weber 763-428-5067 katie@toplinesign.com 10' 11.5"8' 87.7 sq ft 30' 5'15' Katie Weber 10-9-23 LA219119 SIGN PERMIT APPLICATION & ELECTRONIC SIGN LICENSE Page 2 Electronic Display/Changeable Copy Sign License Single occupancy building with gross floor area over 70,000 sq. ft. within the C-3 District and within the Freeway Corridor District. By signing below you are certifying the electronic signage meets the following performance standards: 1.The display sign shall not change more than once every twenty four (24) hours. 2.The display sign shall not include scrolling, flashing, animation, or other effects. 3.The display must be static and the transition from one static display to another must be instantaneous without special effects. 4.The display image or message must be self-contained, without continuation in content to the next image or message. 5.The brightness of the sign shall not exceed 5,000 NITS after sunrise and before sunset or 500 NITS after sunset and before sunrise each day. 6.The sign shall be equipped with an automatic dimmer control or other mechanism that automatically controls the sign’s brightness to comply with this condition. 7.The display must be designed and equipped to freeze the device in one position if a malfunction of the electronic display occurs. 8.The display must also be equipped with a means to immediately discontinue the display if it malfunctions, and the sign owner must immediately stop the electronic display when notified by the City that it is not complying with the stipulations of this section. 9. The sign shall comply with Chapter 23 of the Zoning Ordinance. Signature_______________________________________ Date______________________________ Print Name______________________________________ Email ________________________________ EXPIRATION AND RENEWAL OF LICENSE: •All licenses expire on December 31st of each year. •License may be renewed only by making application as provided in Section 3-22-4 of the City Code. •Application for renewal shall be made at least sixty (60) days before the expiration date. •Each renewal license shall be issued for a maximum period of one (1) year. •Annual license renewal fee is $50.00 Office Use Only Sign Permit Type: Permanent Sign _____ Temporary Sign _____ Electronic Sign _____ Work Type: New _____ Addition _____ Repair _____ Demolish_____ Replace _____ Alter/Remodel _____ Move _____ Owner: Public _____ Private _____ Zoning District: Commercial _____ Industrial _____ Residential_____ Freeway Corridor _____ Required Inspections: Footing _____ Final _____ Permit Fee: Permit Fee _____________ Miscellaneous ___________ Total ___________________ Comments: ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ Approved by:____________________________ Date:___________________________________ (REVISED APRIL 2022) X X X XX C-3 X $75.00 $75.00 11 October 2023 *Call 952.985.4440 to schedule a footing inspection. *Email kjenson@lakevillemn.gov after installation for final inspection. LA219119 Page 1 of 3 PROJECT: GOODWILL DATE: 10/06/23 PROJ. NO.: 41788-1 ENGINEER: PRC CLIENT: SIGN ART USA V5.5 units; pounds, feet unless noted otherwise Applied Wind Loads; from ASCE 7-16 F=qz*G*Cf*Af with qz = 0.00256KzKztKdV2 (29.3.2 & 29.4) Cf=1.740 (Fig. 29.3-1) 2 pole Cf factor= 0.97 13.6247 max. height= 30.000 1.0 Kzt=1.0 (26.8.2) (=1.0 unless unusual landscape)s= 8.00 Kz=from table 28.3-1 Exposure= c 2 Kd=0.85 for signs (table 26.6-1) Lz= V= 110 mph G= 0.85 (26.9)weight= 2.477 kips s/h= 0.267 MDL=0.00 k-ft (see Page #3) B/s= 1.37 Pole structure height at Wind Loads component section c.g Kz qz Af shear Moment MW 1 7.50 0.85 22.38 80.00 2648 19862 2 17.50 0.88 23.06 26.67 910 15921 3 20.54 0.90 23.82 5.78 204 4182 4 23.04 0.93 24.37 63.81 2300 52999 5 27.04 0.96 25.21 66.52 2481 67088 6 29.54 0.98 25.72 4.89 186 5494 sums: 247.67 8729 165.55 (Mw)k-ft arm= 19.0 two pole distribution factor *b*s (asce fig. 29.4-1 ):x 0.55 4778 90.63 Pu=2.97 kip M= 90.63 k-ft M=sqrt(MDL 2+Mw 2) Mu=sqrt(1.2MDL 2+1.0MW 2) =90.63 k-ft Pole Design section; tube Mu <Mn with Mn = fyZ fy=46 ksi = 0.9 H Mu(k-ft)t (in) Z Use at grade 90.63 0.233 32.70 8X8X3/8" SQ. HSS, Mn = 102 k-ft Footing Design footprint: round =1.3 IBC 1605.3.2 IBC Table 1806.2, sections 1806.3.4, 1807.3.2 S=(1.3x2x150psf/ft) P=3.73 kip S1 = S x d / 3 A = 2.34 x P / (S1 x b)S= 400 10' - 0" deep Z req'd. (in) Size(in) 26.27 10 34.12 pressure qz*G*Cf 33.10 35.24 36.05 37.29 38.04 Page 2 of 3 PROJECT: GOODWILL DATE: PROJ. NO.: 41788-1 ENGINEER: CLIENT: SIGN ART USA V5.5 units; pounds, feet unless noted otherwise Longitude Direction applied shear at grade v=5.455 kip unfactored load 8.729 k (factored) applied moment at grade m=103.47 kip-ft unfactored load 165.55 k-ft (factored) depth of soil above footing hs=0.00 ft allowable soil bearing p=2.000 ksf (i.e., 2000 x 1.333 = 2667 psf) (use a factor of 1.33 for wind or seismic) Signage Weight w1 =1.300 k (10'11.5"+2'-8"+2'-8")*(8')*10psf Brick Weight w2 =18.740 k ((2'-8")*(2'-8")*(21'-1")*0.125k/ft^3) Spread Footing Design moment m= 125.29 k-ft Footing size (ft) b=17.00 L=7.00 h=4.00 S= 138.9 Footing Weight= 71.4 k See Above ,w1+w2=20.040 k soil 0.00 total= 91.44 Overturning; Mc=320.04 Mc>1.5M 2.554 ok soil pressure; max= 1.684 ksf min= -0.1 ksf ok forces on concrete pad; V= 72.56 k Vr=116.10 k (=1.6V) M=126.98 k-ft Mr=203.17 k-ft Check Slab; = 0.9 fy=60 ksi fc=2.5 ksi 150 lbs/ft3 Flexure As=1.100 d= 44.0 in Mn=Asfy(d-a/2)=2609 k-in = 217.42 k-ft Mr Mn ok a=Asfy/0.85fcb=0.152 in Check minimum Asmin=3sqrt(fc)bd/fy =22.44 200bd/fy=29.92 or 1.333As=1.47 in2 ACI 10.3.1 Use As=1.47 in2 short direction s=2/(+1) =0.8 with =1.5 short direction;As=1.17 in2 Use #4@12" each direction Shear;Vn=2sqrt(fc)bd Vc== 0.75 Vr Vn ok Top Slab Assume half of footing is in uplift weight= 35.70 kip arm= 1.75 ft M= 62.48 k-ft Mr=74.97 k-ft Flexure As=1.100 Mn=Asfy(d-a/2)=2602.62 k-in = 216.88 k-ft Mr Mn ok a=Asfy/0.85fcb=0.370 in Check minimum Asmin=2sqrt(fc)bd/fy =9.24 200bd/fy=12.32 or 1.333As=1.47 in2 Use As=1.47 in2 short direction s=2/(+1) =0.8 with =1.5 short direction;As=1.17 in2 Use #4@12" each direction 10/06/23 PRC 673.2 Page 3 of 3