Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA219154
THE FOLLOWING INFORMATION MUST BE INCLUDED WITH YOUR APPLICATION: Payment for amount of permit. For freestanding/monument/pylon sign - a site plan with setback from property line dimensions and art work with dimensions of sign, and engineered design for footings and foundation. For wall sign, art work with dimensions of sign and drawings of building façade showing location of sign. If illuminated or if electrical services are needed, a separate electrical permit is required. If leased space, need to include a letter of approval from the property owner. SIGN LOCATION Name__________________________________________________________________________________ Address________________________________________________________________________________ City ____________________________________State__________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ PROPERTY OWNER Name__________________________________________________________________________________ Address________________________________________________________________________________ City ____________________________________State__________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ SIGN CONTRACTOR Company Name _________________________________________________________________________ Address________________________________________________________________________________ City ___________________________________ State___________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ SIGN DESCRIPTION Electronic ($100 per sign plus completion of electronic sign license, see Page 2) Permanent ($75 per sign) Temporary ($50 per event, up to 60 days per year. Max of one temp sign displayed at a time.) Temporary sign displayed dates: START DATE ________________________ END DATE ________________________ Sign Type and Dimensions Wall Sign: Width ____________ Height: _______________ Square feet _____________________________ Freestanding: Face Width_________ Height____________ Sq. ft__________ Overall Sign Height _________ Setbacks: Front _________ Side ____________ Temporary Width___________ Height ______________ Sign Square Feet______________________ Display location _______________________ Illuminated Sign: Internally illuminated Externally illuminated Not illuminated Type of Work: New Sign Replacement Sign Alter Existing Sign Changeable Copy: No Changeable Copy Manual Changeable Copy Electronic Changeable Copy (Electronic sign will require annual license review & renewal, see Page 2) Applicant Signature: ____________________________________________Date:_________________ Applicant Printed Name: _______________________________________________________________ SIGN PERMIT APPLICATION & ELECTRONIC SIGN LICENSE City of Lakeville – Planning Department 20195 Holyoke Avenue - Lakeville, MN 55044 952.985.4420 - www.lakevillemn.gov Marco M. Miller Marco M Miller Jr. LAKEVILLE SPECIALTY CENTER 18465 ORCHARD TRAIL LAKEVILLE Patrick Giordana pgiordana@synergyarchstudio.com 612-383-2701 MINNESOTA 55044 DAVIS REAL ESTATE ARCHETYPE SIGN 33 SOUTH 6TH ST, STE 4650 MINNEAPOLIS MINNESOTA 55402 612-341-3242MARK DAVIS mdavis@davishre.com 9611 JAMES AVE S. BLOOMINGTON MINNESOTA 55431 952-641-9639MARCO MILLER MARCOM@ARCHETYPESIGN.COM 10' X SIGN PERMIT APPLICATION & ELECTRONIC SIGN LICENSE Page 2 Electronic Display/Changeable Copy Sign License Single occupancy building with gross floor area over 70,000 sq. ft. within the C-3 District and within the Freeway Corridor District. By signing below you are certifying the electronic signage meets the following performance standards: 1.The display sign shall not change more than once every twenty four (24) hours. 2.The display sign shall not include scrolling, flashing, animation, or other effects. 3.The display must be static and the transition from one static display to another must be instantaneous without special effects. 4.The display image or message must be self-contained, without continuation in content to the next image or message. 5.The brightness of the sign shall not exceed 5,000 NITS after sunrise and before sunset or 500 NITS after sunset and before sunrise each day. 6.The sign shall be equipped with an automatic dimmer control or other mechanism that automatically controls the sign’s brightness to comply with this condition. 7.The display must be designed and equipped to freeze the device in one position if a malfunction of the electronic display occurs. 8.The display must also be equipped with a means to immediately discontinue the display if it malfunctions, and the sign owner must immediately stop the electronic display when notified by the City that it is not complying with the stipulations of this section. 9. The sign shall comply with Chapter 23 of the Zoning Ordinance. Signature_______________________________________ Date______________________________ Print Name______________________________________ Email ________________________________ EXPIRATION AND RENEWAL OF LICENSE: •All licenses expire on December 31st of each year. •License may be renewed only by making application as provided in Section 3-22-4 of the City Code. •Application for renewal shall be made at least sixty (60) days before the expiration date. •Each renewal license shall be issued for a maximum period of one (1) year. •Annual license renewal fee is $50.00 Office Use Only Sign Permit Type: Permanent Sign _____ Temporary Sign _____ Electronic Sign _____ Work Type: New _____ Addition _____ Repair _____ Demolish_____ Replace _____ Alter/Remodel _____ Move _____ Owner: Public _____ Private _____ Zoning District: Commercial _____ Industrial _____ Residential_____ Freeway Corridor _____ Required Inspections: Footing _____ Final _____ Permit Fee: Permit Fee _____________ Miscellaneous ___________ Total ___________________ Comments: ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ Approved by:____________________________ Date:___________________________________ (REVISED APRIL 2022) X X X $75.00 $75.00 X X PUD 19 October 2023 *Call 952.985.4440 to schedule the required footing inspection. *Email kjenson@lakevillemn.gov after installation for final inspection. *Maximum overall height of the sign is 10 feet. 1.8 DF Monument Sign Scale: 3/8’’ = 1’-0’’1 DF Monument Sign 6” 21 1/2” 21 1/2” 21 1/2” 21 1/2” 24” 121” 156” 158” 24” 26” 1” 1” 1” 1” 1” PROFILE STEEL STRUCTURE MOUNTED TO EXISTING MASONRY BASE - EMBEDDED 3/4’’ X 22’’ THREADED ROD ANCHORS AND HARDWARE (18’’ EMBEDMENT) MECHANICALLY MOUNT CABINET OVER 2- 4’’ SQ. STEEL TUBES (3/8’’ WALL) - WELDED TO 12’’ X 12’’ X 3/4’’ STEEL MOUNTING PLATE - 1 1/4’’ X 1 1/4’’ X 1/2’’ STEEL GUSSETS Description Install Mount Illumination DF Cabinets Cornice Reveals Tenant Panels Base 2’’ X 2’’ X 3/16’’ WALL ALUMINUM ANGLE FRAME WELDED CONSTRUCTION - .080 ALUMINUM RETURNS - 2’’ ALUMINUM ANGLE RETAINERS 1 1/2’’ ALUMINUM DIVIDER BARS - PAINTED BRUSHED ALUMINUM 6’’ X 3’’ ALUMINUM CHANNEL - WELDED CONSTRUCTION - .080 ALUMINUM TOP - PAINTED BRUSHED ALUMINUM 1’’ X 1’’ ALUMINUM CHANNEL REVEAL - PAINTED BRUSHED ALUMINUM 1 1/2’’ X 1 1/2’’ X 1/8’’ ALUMINUM ANGLE FRAME RETAINER - 1/8’’ ALUMINUM PANELS (CNC) - PAINTED BRUSHED ALUMINUM - 1/2’’ CLEAR ACRYLIC PUSH-THRU GRAPHICS - 1/4’’ PROJECTION SECOND SURFACE VINYL DIFFUSER (3635-30) MASONRY BASE (BY OTHERS) A A B B E E C D F F PHOTOCELL CONTROLLER SLOAN DS SIGNBOX 3 6500K WHITE LED MODULES 88 L.E.D. MODULES - 88 LINEAL FEET TOTAL (5) - 60C2-60W (701507-60C2) 100-277 VAC 60 Hz 0.80 A - 60 W @ 12 VDC8 Tenant Graphics MNGI: DIGITALLY PRINTED WHITE VINYL OVERLAY GRAPHICS (IJ3630) - COLORS TO MATCH: BLUE: PMS 7692C & TEAL: PMS 2389C (C/W/C)(NYALA) CLEAR MATTE LAMINATE D C 14 5/8” ALLINA HEALTH ALLINA HEALTH ALLINA HEALTH 9611 James Ave S. Minneapolis, Minnesota 55431 952 641 9600 archetypesign.com This print is meant as a representation of a sign show vin consideration of being manufactured by Archetype. Materials may influence final result. Samples available upon request. Graphic Design time is included in the total purchase price. Designs contained herein are not meant to be exhibited to others outside of included parties and employees. Designs received from Archetype may not be manufactured by others without reimbursement for time spent in the creation of these designs or any resemblance. Drawings may contain elements considered artistic intellectual property of Steve Carpenter, owner. ©Archetype Page: Type: Approved: Contact: Description: Project: Job Number: Date: Rev. 1: Rev. 2: Rev. 3: Rev. 4: Rev. 5: Rev: 6: Rev. 7: Designer: Steve Hirtz 952 641 9629 steveh@archetypesign.com Lakeville Health Q-102583 10.13.22 10.18.22 11.11.22 01.03.23 MF 07.12.23 07.14.23 08.15.23 08.25.23 DG 1.9 DF Monument Sign Details Scale: 3/8’’ = 1’-0’’2 DF Monument Sign Details 6” 21 1/2” 21 1/2” 21 1/2” 21 1/2” 24” 121” 156” 158” 24” 26” 1” PROFILE 84"c.c. 89” 18" 20" GRADE 3’’ X 6’’ ALUM. CHANNEL 2’’ ALUM. ANGLE FRAME LED MODULE 4’’ SQ. STEEL TUBE (90’’ LENGTH) MOUNTING ANGLE & HARDWARE STEEL MOUNTING PLATE THREADED ANCHORS/ HARDWARE (LEVELING NUTS) INCOMING ELECTRICAL LOCATION TBD MASONRY BASE (BY OTHERS)MASONRY BASE (BY OTHERS) 1’’ X 1’’ ALUM. CHANNEL (T YP) 1/8” ALUM. FACE 1/2” ACRYLIC PUSH-THRU Scale: 1 1/2’’ = 1’-0’’ 2’’ ALUM. ANGLE FRAME ATTACHMENT SCREW 1 1/2’’ ALUM. ANGLE ADHESIVE 1/8” ALUM. FACE 1/2’’ ACRYLIC PUSH-THRU .063 ALUMINUM FLASHING 3/4’’ Base Plate Detail Scale: 1 1/2’’ = 1’-0’’3 8” 8” 12” 12” 7/8” 4’’ SQ. STEEL TUBE STEEL GUSSET 1/2” 1 1/4” c.c. c.c. Footing Detail (By Others) Scale: NTS424”9611 James Ave S. Minneapolis, Minnesota 55431 952 641 9600 archetypesign.com This print is meant as a representation of a sign show vin consideration of being manufactured by Archetype. Materials may influence final result. Samples available upon request. Graphic Design time is included in the total purchase price. Designs contained herein are not meant to be exhibited to others outside of included parties and employees. Designs received from Archetype may not be manufactured by others without reimbursement for time spent in the creation of these designs or any resemblance. Drawings may contain elements considered artistic intellectual property of Steve Carpenter, owner. ©Archetype Page: Type: Approved: Contact: Description: Project: Job Number: Date: Rev. 1: Rev. 2: Rev. 3: Rev. 4: Rev. 5: Rev: 6: Rev. 7: Designer: Steve Hirtz 952 641 9629 steveh@archetypesign.com Lakeville Health Q-102583 10.13.22 10.18.22 11.11.22 01.03.23 MF 07.12.23 07.14.23 08.15.23 08.25.23 DG 18 8 4 2 FD FD UP PROPOSED BUILDING FFE-1068.50 GFE-1056.25 40.0' 27.0' 15.0' 24.0' 20.0' 20.0' 15.0' 6.0' 10 16 17 17 18 8 3'R 3'R 3'R 3'R 3'R 3'R 3'R 4'R 4'R 20'R 5'R 7'R CONCRETE SIDEWALK (SEE ARCH PLANS FOR STOOP INFO) EDGE OF NEW BITUMINOUS 25'R 3'R 7'R 71'R 65'R 50'R 3'R 24.0' 20.0' 20.0' TIE PROPOSED RETAINING WALL INTO EXISTING MODULAR BLOCK RETAINING WALL (SEE GRADING PLAN) 2 15.0' MONUMENT SIGN. SEE ARCHITECTURAL. 20'R B612 CURB/ GUTTER SEE ARCH AND STRUCTURAL PLANS FOR PARKING GARAGE AND GARAGE ROOFTOP PARKING INFORMATION AND PRECAST DECK PARKING STRUCTURE GARAGE TO LOWER LEVEL GARAGE 2 TIE CURB/GUTTER INTO EXISTING 28.3' 36.6' 26.0' 26.0' 14.7' 16.3' 5' WIDE SIDEWALK 29.4' 30'R MODULAR BLOCK RETAINING WALL (SEE GRADING PLAN) SEE ARCH AND STRUCTURAL PLANS FOR LOWER LEVEL TUNNEL INFO STORM BASIN STORM BASIN CONCRETE PAD FOR GENERATOR - SEE MECHANICAL FOR PAVEMENT INFORMATION RAISED CONCRETE PAVEMENT FOR CARD READER (SEE ARCH PLANS) AREA WELL (SEE ARCH PLANS SEE ARCH PLAN FOR STOOP INFORMATION-TYP AREA WELL (SEE ARCH PLANS MATCH PROPOSED SIDEWALK TO SIDEWALK ON PARKING DECK (SEE STRUCTURAL) SEE ARCH PLANS FOR TRASH ENCLOSURE MODIFICATIONS 9.0' 9.0' 9.0' 9.0' 20.0' 18.0' DRAINAGE TRENCH (SEE GRADING PLAN,UTILITY PLAN, AND CIVIL DETAILS FOR INFO AREA WELL (SEE ARCH PLANS) 40'R NO GRADING BEYOND CONSERVATION EASEMENT LINE. SEE ARCH/STRUCTURAL PLANS REGARDING MEASURES TAKEN TO INHIBIT ANY DISTURBANCE WITHIN THE EASEMENT STOP SIGN (SEE NOTES) HC SIGN (CONTRACTOR TO COORD. W/ STRUCTURAL FOR ANCHOR NO PARKING SIGN (SEE NOTE) 8'X8' CONCRETE PAD FOR TRANSFORMER (BY OTHERS) 17 PROOF OF PARKING STALLS 2'R 4 PROOF OF PARKING STALLS B612 CURB/GUTTER TERMINATE B612 CURB/GUTTER AT STRUCTURAL WALL TERMINATE B612 CURB/GUTTER AT STRUCTURAL WALL B612 CURB/GUTTER 2-CONCRETE REINFORCED STEPS 5.0' N SCALE IN FEET 0 30 60 05/01/20 CITY SUBMITTAL 07/21/20 CITY SUBMITTAL 08/20/20 CITY COMMENTS 10/19/21 CITY SUBMITTAL 01/26/22 CITY SUBMITTAL 03/28/22 CITY SUBMITTAL 04/07/22 CONST. DOCS. 4/12/21 CITY COMMENTS 4/22/22 ADDENDUM A 04/29/22 ADDENDUM B 05/04/22 ADDENDUM C Review Date SHEET INDEX License No. Date I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. PJ Disch - PE 49933 Project Lead Drawn By Checked By Loucks Project No.19730 PJD DDL PJD 05/08/23 04/07/22 LOUCKS W:\2019\19730\CADD DATA\CIVIL\_dwg Sheet Files\C2-1 Site PlanPlotted: 05 /08 / 2023 9:22 AM7200 Hemlock Lane, Suite 300 Maple Grove, MN 55369 763.424.5505 www.loucksinc.com PLANNING CIVIL ENGINEERING LAND SURVEYING LANDSCAPE ARCHITECTURE ENVIRONMENTAL SUBMITTAL/REVISIONS PROFESSIONAL SIGNATURE QUALITY CONTROL CADD files prepared by the Consultant for this project are instruments of the Consultant professional services for use solely with respect to this project. These CADD files shall not be used on other projects, for additions to this project, or for completion of this project by others without written approval by the Consultant. With the Consultant's approval, others may be permitted to obtain copies of the CADD drawing files for information and reference only. All intentional or unintentional revisions, additions, or deletions to these CADD files shall be made at the full risk of that party making such revisions, additions or deletions and that party shall hold harmless and indemnify the Consultant from any & all responsibilities, claims, and liabilities. CADD QUALIFICATION LAKEVILLE HEALTH LAKEVILLE, MN 33 SOUTH 6TH STREET, SUITE 4650 MINNEAPOLIS, MN 55402 C1-1 C2-1 C3-1 C3-2 C3-3 C4-1 C8-1 C8-2 L1-1 L1-2 DEMOLITION PLAN SITE PLAN GRADING PLAN SWPPP SWPPP NOTES UTILITY PLAN CIVIL DETAILS CIVIL DETAILS LANDSCAPE PLAN LANDSCAPE DETAILS 05/11/22 CITY SUBMITTAL 05/24/22 CITY SUBMITTAL 06/07/22 ADDENDUM E 11/21/22 CHANGE DIRECTIVE 7 01/05/23 CHANGE DIRECTIVE 8 05/08/23 CHANGE DIRECTIVE 13 PARKING STALL COUNT ACCESSIBLE PARKING STALL 2 LEGEND CATCH BASIN STORM SEWER SANITARY SEWER WATERMAIN STORM MANHOLE SANITARY MANHOLE HYDRANT GATE VALVE SPOT ELEVATION SIGN LIGHT POLE POWER POLE WATER MANHOLE / WELL CONTOUR CONCRETE CURB UNDERGROUND ELECTRIC CONCRETE TELEPHONE PEDESTAL UNDERGROUND TELEPHONE UNDERGROUND GAS OVERHEAD UTILITY CHAIN LINK FENCE BUILDING RETAINING WALL NO PARKING UNDERGROUND FIBER OPTIC SANITARY SEWER SERVICE WATER SERVICE ELECTRIC METER GAS METER TREE LINE EXISTING PROPOSED 972 DRAINTILE FORCEMAIN 373PARKING SETBACK LINE BUILDING SETBACK LINE 2 FENCE FLARED END SECTION POST INDICATOR VALVE BENCHMARK SOIL BORING 3DIRECTION OF FLOW 1.0% 972.5 DENOTES CONCRETE SIDEWALK DENOTES BITUMINOUS PAVEMENT PAVEMENT LEGEND TOLL FREE: 1-800-252-1166 TWIN CITY AREA: 651-454-0002 Gopher State One Call CALL BEFORE YOU DIG! WARNING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER. SITE PLAN C2-1 CURRENT ZONING:PUD - PLANNED UNIT DEVELOPMENT DISTRICT BUILDING SETBACK:40 FT. FRONT, 25' SIDE PROPERTY AREA:4.236 AC. PROPOSED IMPERVIOUS AREA:3.218 AC. (75.97%) PROPOSED PERVIOUS AREA:1.018 AC. (24.03%) 1.ALL PAVING, CONCRETE CURB, GUTTER AND SIDEWALK SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH THE DETAILS SHOWN PER THE DETAIL SHEET(S) AND STATE/LOCAL JURISDICTION REQUIREMENTS. 2.ACCESSIBLE PARKING AND ACCESSIBLE ROUTES SHALL BE PROVIDED PER CURRENT ADA STANDARDS AND LOCAL/STATE REQUIREMENTS. 3.ALL CURB DIMENSIONS SHOWN ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED. 4.ALL BUILDING DIMENSIONS ARE TO THE OUTSIDE FACE OF WALL UNLESS OTHERWISE NOTED. 5.TYPICAL FULL SIZED PARKING STALL IS 9' X 20' WITH A 24' WIDE TWO WAY DRIVE OR 9'X18' WITH CURB OVERHANG 6.ALL CURB RADII SHALL BE 3.0' UNLESS OTHERWISE NOTED. 7.BITUMINOUS IMPREGNATED FIBER BOARD TO BE PLACED AT FULL DEPTH OF CONCRETE ADJACENT TO EXISTING STRUCTURES AND BEHIND CURB ADJACENT TO DRIVEWAYS AND SIDEWALKS. 8.SEE SITE ELECTRICAL PLAN FOR SITE LIGHTING. 9.ALL SIGN POSTS TO BE 2.25" Ø ALUMINUM POSTS. 10.CONTRACTOR TO SUBMIT SHOP DRAWING OF MODULAR BLOCK WALLS TO CIVIL ENGINEER FOR REVIEW AN APPROVAL PRIOR TO INSTALLATION. SHOP DRAWINGS TO BE DESIGNED AND SIGNED BY A LICENSED ENGINEER. SEE ARCHITECTURAL PLANS FOR RETAINING WALL PRODUCT/COLOR INFORMATION. 11.ALL DRIVE LANES TO BE HEAVY-DUTY BITUMINOUS PAVEMENT AND PARKING STALLS TO BE STANDARD DUTY BITUMINOUS. SEE DETAIL ON C8-1 OFF-STREET PARKING CALCULATIONS CITY PARKING REQUIREMENT: GROSS BUILDING MINUS 10% THEN ONE STALL PER 200 SF. REQUIRED STALLS = 100,000 SF x 90% = 90,000 SF..... 90,000/200 = 450 STALLS PROPOSED SURFACE STALLS = 90 PROPOSED SURFACE STALLS ON DECK = 128 (INCLUDES 8 HANDICAP STALLS) UNDERGROUND STALLS =205 (INCLUDES 2 HANDICAP STALLS) PROOF OF PARKING = 21 TOTAL PROPOSED STALLS = 444 SITE NOTES SITE DATA DENOTES HEAVY DUTY CONCRETE SIGNAGE INFORMATION STOP SIGN - R1-1 NO PARKING SIGN - R8-31 MONUMENT DIRECTIONAL SIGN: RIGHT- LAKEVILLE SPECIALTY CENTER DIRECTIONAL SIGN: LEFT - PATIENT DROP OFF FORWARD - PATIENT PARKING OVERHEAD MAX LOAD / CLEARANCE SIGN STAFF PARKING ENTRANCE / CLERANCE EXIT OVERHEAD MAX LOAD / CLEARANCE SIGN WALL SIGN: BUILDING NAME WALL SIGN: TENANT A WALL SIGN: TENANT B WALL SIGN: TENANT C WALL SIGN: TENANT D SIGN NOTES 7'-6" MNGI ALLINA HEALTH ALLINA HEALTH SURGERY CENTER URGENT CARE