Loading...
HomeMy WebLinkAboutLA219613-APPROVED - PP Permit Pack 1494 nevil kabrawala Stamped FLAT1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nevil kabrawala7037 184 st westLakeville Minnesota 55044AC SYSTEM SIZE: 3.15 kW ACDC SYSTEM SIZE: 4.2 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore October 27, 2023 886134 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 COVER SHEET PV1 GENERAL NOTES CODE AND STANDARDS SITE NOTES / OSHA REGULATION SOLAR CONTRACTOR EQUIPMENT LOCATIONS AERIAL VIEW DESIGN CRITERIA WIND SPEED:115 mph GROUND SNOW LOAD:50 lb/ft² WIND EXPOSURE FACTOR:C SEISMIC DESIGN CATEGORY:B SITE SPECIFICATIONS CONSTRUCTION - V-B ZONING: RESIDENTIAL SHEET INDEX PV1 - COVER SHEET PV2 - SITE PLAN PV3 - ROOF PLAN PV4 - STRUCTURAL PV5 - ELECTRICAL 3-LINE DIAGRAM PV6 - ELECTRICAL CALCULATIONS PV7 - WARNING LABELS AND LOCATIONS PV8 - PLACARD (ALL OTHER SHEETS AS REQUIRED) SS - PRODUCT SPEC. SHEETS UTILITY COMPANY: Dakota Electric Association PERMIT ISSUER: City of Lakeville PROJECT INFORMATION: NUMBER OF STORIES:2 CONDUIT RUN:Interior ECOBEE QTY:0 LIGHT BULB QTY:0 PV METER:Utility PV Meter Required ROOF TYPE (1) INFORMATION: ROOF TYPE:Comp Shingle FRAMING TYPE:Manufactured Truss SHEATHING TYPE:OSB ATTACHMENT:SFM Infinity Flashkit RACKING:Unirac SFM Infinity @ 24" OC Portrait / 48" OC Landscape NUMBER OF ATTACHMENTS:25 ROOF TYPE (2) INFORMATION (IF APPLICABLE): *SEE PV4.2 SCOPE OF WORK INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. SYSTEM TO BE INSTALLED INFORMATION: DC SYSTEM SIZE:4.2 kW DC AC SYSTEM SIZE:3.15 kW AC MODULE TYPE: (10) REC Solar REC420AA PURE-R INVERTER TYPE:Enphase IQ7X-96-2-US MONITORING:Enphase IQ Combiner 4 X-IQ-AM1-240-4 Sealed For Existing Roof & Attachment Only 10/27/23 I hereby certify that this plan, specification or report wasprepared by me or under my direct supervision and that I am aduly Licensed Professional Engineer under the laws of the Stateof Minnesota.John A. Calvert, License No. 52823 ExpirationDate: 30-June-2024 Digitally signed by John A. Calvert Date: 2023.10.27 13:05:39 -06'00' Concept Approval ONLYSubject to Field Inspection Inspector Date 2015 MN Bldg Code 10/30/2023jnuetzman DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC M PV AC CB MSP SUB 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nevil kabrawala7037 184 st westLakeville Minnesota 55044AC SYSTEM SIZE: 3.15 kW ACDC SYSTEM SIZE: 4.2 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore October 27, 2023 886134 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 SITE PLAN PV2 SCALE: 3/32" = 1'-0" ---- M MSP AC CB LC SUB PV TS MAIN SERVICE PANEL UTILITY METER AC DISCONNECT COMBINER BOX LOAD CENTER SUBPANEL PV METER TRANSFER SWITCH JUNCTION BOX LEGEND FIRE SETBACK TRENCHING PROPERTY LINE ESS HUB RPO SUNPOWER ESS SUNPOWER HUB+ REMOTE POWER OFF PV SYSTEM SPECIFICATIONS TOTAL NUMBER OF MODULES:10 MODULE MAKE AND MODEL:REC Solar REC420AA PURE-R MODULE WATTAGE:420W DC INVERTER MAKE AND MODEL:Enphase IQ7X-96-2-US INVERTER TYPE: Microinverter (1 Inverter per PV Module) INVERTER CURRENT OUTPUT:1.31A AC INVERTER NOMINAL VOLTAGE: 240V INVERTER WATTAGE:315W AC FRONT OF HOME 7037 184 ST WEST Sealed For Existing Roof & Attachment Only 10/27/23 I hereby certify that this plan, specification or report wasprepared by me or under my direct supervision and that Iam a duly Licensed Professional Engineer under the lawsof the State of Minnesota.John A. Calvert, License No.52823 Expiration Date: 30-June-2024 DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC DCAC M PV AC CB MSP SUB 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nevil kabrawala7037 184 st westLakeville Minnesota 55044AC SYSTEM SIZE: 3.15 kW ACDC SYSTEM SIZE: 4.2 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore October 27, 2023 886134 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 ROOF PLAN PV3---- SCALE: 1/8" = 1'-0" M MSP AC CB LC SUB PV TS MAIN SERVICE PANEL UTILITY METER AC DISCONNECT COMBINER BOX LOAD CENTER SUBPANEL PV METER TRANSFER SWITCH JUNCTION BOX LEGEND FIRE SETBACK TRENCHING PROPERTY LINE ESS HUB RPO SUNPOWER ESS SUNPOWER HUB+ REMOTE POWER OFF PV SYSTEM SPECIFICATIONS TOTAL NUMBER OF MODULES:10 MODULE MAKE AND MODEL:REC Solar REC420AA PURE-R MODULE WATTAGE:420W DC INVERTER MAKE AND MODEL:Enphase IQ7X-96-2-US INVERTER TYPE: Microinverter (1 Inverter per PV Module) INVERTER CURRENT OUTPUT:1.31A AC INVERTER NOMINAL VOLTAGE: 240V INVERTER WATTAGE:315W AC FRONT OF HOME MP1 # OF MODULES: 10 AZIMUTH: 180 PITCH: 27 TSRF: 99% AREA: 730 ft.² POINT OF INTERCONNECTION UNDERGROUND SERVICE LINE 3' 1'-6" 1'-6" 3' 3' Sealed For Existing Roof & Attachment Only 10/27/23 I hereby certify that this plan, specification or report was prepared byme or under my direct supervision and that I am a duly LicensedProfessional Engineer under the laws of the State of Minnesota.JohnA. Calvert, License No. 52823 Expiration Date: 30-June-2024 ATTACHMENT SPACING- SIDE VIEWDSCALE: 1/2" = 1'-0" B A LANDSCAPE PORTRAIT A B MODULE WIDTH MODULE WIDTH PV MODULE ROOF STRUCTURE 27° PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 6.5" SPLICE PV MODULE UNIRAC SFM 2" MICRORAIL " MAX.48" MAX. " MAX.24" MAX. ATTACHMENT SPACING- FRONT VIEWCSCALE: 3/4" = 1'-0" UNIRAC SFM 8" ATTACHED SPLICE LANDSCAPE PORTRAIT BOTTOM STANDOFF DETAILBSCALE: 3" = 1'-0" MIDDLE/TOP STANDOFF DETAILASCALE: 3" = 1'-0" UNIRAC SFM INFINITY REC SOLAR REC420AA PURE-R PV MODULE UNIRAC SFM MICRORAIL/ SPLICE (E) ROOF SHEATHING FLASHING UNIRAC SFM SLIDER (1) 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER (E) BUILDING STRUCTURE 212" MIN. EMBED. REC SOLAR REC420AA PURE-R PV MODULE (E) ROOF SHEATHING FLASHING UNIRAC SFM SLIDER AND TRIMRAIL ROOF ATTACHMENT (1) 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER (E) BUILDING STRUCTURE 212" MIN. EMBED. UNIRAC SFM TRIMRAIL 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nevil kabrawala7037 184 st westLakeville Minnesota 55044AC SYSTEM SIZE: 3.15 kW ACDC SYSTEM SIZE: 4.2 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore October 27, 2023 886134 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 STRUCTURAL PV4 STRUCTURAL INFORMATION: ROOF TYPE (1): ROOF TYPE: Comp Shingle SHEATHING TYPE: OSB FRAMING TYPE: Manufactured Truss FRAMING SIZE: 2x4 @ 24" OC CEILING JOIST SIZE: 2x4 @ 24" OC ATTACHMENT: SFM Infinity Flashkit RACKING: Unirac SFM Infinity @ 24" OC Portrait / 48" OC Landscape NUMBER OF ATTACHMENTS: 25 PV MODULE COUNT: 10 Modules TOTAL ARRAY AREA: 204.0 ft² (20.4ft²/panel) TOTAL ROOF AREA: 2562 ft² ARRAY/ROOF AREA: 8% ARRAY WEIGHT: 500 lbs (50 lbs/panel) DISTRIBUTED LOAD: 2.45 lbs/ft² POINT LOAD: 20 lbs/attachment STRUCTURAL NOTES: ---- None *NOTE: LISTED NUMBER OF ATTACHMENT POINTS ARE AN ESTIMATE ONLY AND MAY VARY BASED ON FIELD CONDITIONS. MAXIMUM ATTACHMENT SPACING TO BE FOLLOWED PER ENGINEER OF RECORD SPECIFICATIONS. -RACKING ATTACHMENTS TO BE STAGGERED Sealed For Existing Roof & Attachment Only 10/27/23 I hereby certify that this plan, specification or report was prepared byme or under my direct supervision and that I am a duly LicensedProfessional Engineer under the laws of the State of Minnesota.JohnA. Calvert, License No. 52823 Expiration Date: 30-June-2024 UTILITY COMPANY:Dakota Electric Association PERMIT ISSUER: City of Lakeville ELECTRICAL NOTES: ---- DESIGNER NOTES: INTERCONNECT USING A LOAD SIDE BREAKER IN MSP, INTERIOR POI. (1) CIRCUIT OF 10 MODULES JB-1L1L2EGC L1L2 (N) 20A / 2P L1L2EGC 12 JB EGC N G 15A / 2P ENVOY ENPHASE IQ COMBINER 4 X-IQ-AM1-240-4 (SOLAR LOAD ONLY) 3 *JUNCTION BOX OPTIONAL IF UF-B CABLE USED FOR ENTIRE HOMERUN JB-1 EZ SOLAR JUNCTION BOX 4"x4"x4" PVC JUNCTION BOX (10) REC Solar REC420AA PURE-R UL 1703 COMPLIANT (10) Enphase IQ7X-96-2-US 1 PHASE, UL 1741 COMPLIANT UTILITY PV PRODUCTION METER EGC L1 L2 N 15 PV AC DISCONNECT NON-FUSED LOCKABLE, VISIBLE OPEN 30A, 240V, 2-POLE L1 L2NEGC 15 LINE LOAD 120/240 VAC 60HZ 1 PHASE TO UTILITY GRID (E) 150A / 2P (N) 20A / 2P (E) LOADS (E) GROUNDING ELECTRODE(S) L2 L1 NEGC (E) LOADS (E) LOADS FEED THROUGH LUGS AT END OF BUSSING L2 L1 N EGC N G N G (E) 150A MAIN SERVICE PANEL (E) 150A / 2P MAIN BREAKER INTERCONNECTION NOTES 705.12(B)(3) THE FOLLOWING METHOD(S) SHALL BE USED TO DETERMINE THE RATINGS OF BUSBARS: (6) CONNECTIONS SHALL BE PERMITTED ON BUSBARS OF PANEL-BOARDS THAT SUPPLY LUGS CONNECTED TO FEED-THROUGH CONDUCTORS. THE FEED THROUGH CONDUCTORS SHALL BE SIZED IN ACCORDANCE WITH 705.12(B)(1). 15 (E) (E) 150A SUBPANEL (E) 150A / 2P IF REQUIRED, VERIFICATION WILL BE DONE TO ENSURE THE GROUNDING ELECTRODE SYSTEM IS CONGRUENT WITH CURRENT REQUIREMENTS. (NEC 250 PART III) IF NOT, A NEW GROUND ROD WILL BE INSTALLED. (N) 58" COPPER GROUND ROD,8' LONG, MIN. 6' FROM (E)GROUNDING CONDUCTOR. GEC INSTALLED PER NEC 250.64: 6 OR 4 AWG SOLID COPPER GEC. 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nevil kabrawala7037 184 st westLakeville Minnesota 55044AC SYSTEM SIZE: 3.15 kW ACDC SYSTEM SIZE: 4.2 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore October 27, 2023 886134 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 ELECTRICAL PV5 GROUNDING NOTES 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH [NEC 690.47] AND [NEC 250.50-60] SHALL BE PROVIDED. PER [NEC 690.47], THE GROUNDING ELECTRODE SYSTEM OF AN EXISTING BUILDING MAY BE USED AND BE BONDED AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 2. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE PER [NEC 250.64(B)]. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER [NEC 250.64(C)]. 3. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN 8 AWG AND NO GREATER THAN 6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 4. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO [NEC 250.21], [NEC TABLE 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO [NEC 690.46]. 5. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO [NEC 690.42]. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED IN THEMANUFACTURER'S INSTALLATION INSTRUCTIONS. 8. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. 9. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER, SOLID OR STRANDED, AND BARE WHEN EXPOSED.11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO [NEC 690.45] AND BE A MINIMUM OF 10 AWG WHEN NOT EXPOSED TO DAMAGE (6 AWG SHALL BE USED WHEN EXPOSED TO DAMAGE). 12. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN (OR MARKED GREEN IF 4 AWG OR LARGER). 13. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.66], DC SYSTEM GEC SIZED ACCORDING TO [NEC 250.166], MINIMUM 8 AWG WHEN INSULATED, 6 AWG WHEN EXPOSED TO DAMAGE. 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH [NEC 250.134] OR [NEC 250.136(A)] REGARDLESS OF VOLTAGE. WIRING & CONDUIT NOTES 1. ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATIONS. 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR (USE POLARIS BLOCK OR NEUTRAL BAR). 3. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT. REDUCING WASHERS DISALLOWED ABOVE LIVE PARTS, MEYERS HUBS RECOMMENDED 4. UV RESISTANT CABLE TIES (NOT ZIP TIES) USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF SURFACE IN ACCORDANCE WITH [NEC 110.2,110.3(A-B)]. 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH WITH ROOF SURFACE TO BE USED FOR WIRE MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2, AND SINGLE-CONDUCTOR CABLE LISTED AND IDENTIFIED AS PV WIRE, TYPE TC-ER, OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED. 7. ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [NEC 690.8] FOR MULTIPLE CONDUCTORS. 8. ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/8"ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (B)(2)(A)], [NEC TABLE310.15(B)(3)(A)],& [NEC 310.15(B)(3)(C)]. 9. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES. 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 600V 11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUNDMARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. 12. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION 13. VOLTAGE DROP LIMITED TO 2% FOR DC CIRCUITS AND 3% FOR AC CIRCUITS 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC POSITIVE- RED (OR MARKED RED), DC NEGATIVE- GREY (OR MARKED GREY) 15. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: DC POSITIVE- GREY (OR MARKED GREY), DC NEGATIVE- BLACK (OR MARKED BLACK) 16. AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY * USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE ** USE-2 IS AVAILABLE AS UV WHITE 17. RIGID CONDUIT, IF INSTALLED, (AND/OR NIPPLES) MUST HAVE A PULL BUSHING TO PROTECT WIRES.18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH [NEC 690.31], [NEC 250.118(10)]. DISCONNECTING MEANS SHALL COMPLY WITH [NEC 690.13] AND [NEC 690.15]. 19. CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18" BELOW ROOF SURFACE COMPLYING WITH [NEC 230.6(4)] AND SECURED NO GREATER THAN 6' APART PER [NEC 330.30(B)]. 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nevil kabrawala7037 184 st westLakeville Minnesota 55044AC SYSTEM SIZE: 3.15 kW ACDC SYSTEM SIZE: 4.2 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore October 27, 2023 886134 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 ELEC CALCS PV6 LABEL 1 FOR PV SYSTEM DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION. [2017 NEC 690.13(B)] [2020 NEC 690.13(B)] LABEL 2 SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT THE DISCONNECTING MEANS AS A POWER SOURCE AND WITH THE RATED AC OUTPUT CURRENT AND THE NOMINAL OPERATING AC VOLTAGE. [2017 NEC 690.54] [2020 NEC 690.54] LABEL 3 IF INTERCONNECTING LOAD SIDE, INSTALL THIS LABEL ANYWHERE THAT IS POWERED BY BOTH THE UTILITY AND THE SOLAR PV SYSTEM, IE. MAIN SERVICE PANEL AND SUBPANELS. [2017 NEC 705.12(B)(3)] [2020 NEC 705.12(B)(3)] LABEL 4 APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER FROM THE POWER SOURCE. [2017 NEC 705.12(B)(2)(3)(b)] [2020 NEC 705.12(B)(3)(2)] LABEL 6 BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN APPROVED READILY VISIBLE LOCATION AND SHALL INDICATE THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES. [2017 NEC 690.56(C)(1)(a)] [2020 NEC 690.56(C)] LABEL 7 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH [2017 NEC 690.56(C)(3)] [2020 NEC 690.56(C)(2)] LABEL 8 PERMANENT PLAQUE OR DIRECTORY DENOTING THE LOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ON OR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. [2017 NEC 705.10] [2020 NEC 705.10] LABEL 9 PERMANENT PLAQUE OR DIRECTORY DENOTING THE LOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ON OR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. [2017 NEC 705.10] [2020 NEC 705.10] LABEL 10 PERMANENT PLAQUE OR DIRECTORY TO BE LOCATED AT MAIN SERVICE EQUIPMENT DENOTING THE LOCATION OF THE RAPID SHUTDOWN SYSTEM DISCONNECTING MEANS IF SOLAR ARRAY RAPID SHUTDOWN DISCONNECTING SWITCH IS NOT GROUPED AND WITHIN LINE OF SITE OF MAIN SERVICE DISCONNECTING MEANS. [2017 NEC 705.10 AND 690.56(C)(1)(a)] [2020 NEC 705.10 AND 690.56(C)] LABEL 11 PERMANENT PLAQUE OR DIRECTORY TO BE LOCATED AT AC COMBINER PANEL. [2017 NEC 110.21(B)] [2020 NEC 110.21(B)] ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! PHOTOVOLTAIC SYSTEM AC DISCONNECT!! 240 VNOMINAL OPERATING AC VOLTAGE RATED AC OUTPUT CURRENT 13.1 A DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING! POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING! SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE"OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCESHOCK HAZARDIN THE ARRAY SOLAR ELECTRICPV PANELS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM MAIN DISTRIBUTION UTILITY DISCONNECT(S) POWER TO THIS BUILDING IS ALSO SUPPLIEDFROM A ROOF MOUNTED SOLAR ARRAY WITH A RAPID SHUTDOWN DISCONNECTING MEANS GROUPED AND LABELED WITHIN LINE OF SITEAND 10 FT OF THIS LOCATION WARNING! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM MAIN DISTRIBUTION UTILITY DISCONNECT LOCATED WARNING! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A ROOF MOUNTED SOLAR ARRAY. SOLAR ARRAY RAPID SHUTDOWN DISCONNECT IS LOCATED OUTSIDE NEXT TO THE UTILITY METER. WARNING! PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS WARNING! 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nevil kabrawala7037 184 st westLakeville Minnesota 55044AC SYSTEM SIZE: 3.15 kW ACDC SYSTEM SIZE: 4.2 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore October 27, 2023 886134 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 LABELS PV7 ADDITIONAL LABELS *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. UTILITY METER MAIN SERVICE PANEL 1 6 2 3 IF BREAKER IS USED4 8 10OR OR PLACARD SUBPANEL (IF INTERCONNECTION IS MADE HERE) 1 6 2 3 4 9 AC DISCONNECT 1 2 7 9 OR PLACARD PV COMBINER BOX 11 PV METER (IF APPLICABLE) LABELING NOTES 1) LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2) LABELING REQUIREMENTS BASED ON THE 2017 & 2020 NEC CODE, OSHA STANDARD 19010.145, ANSIZ535. 3) MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. 4) LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE HANDWRITTEN [NEC 110.21] STANDARD LABELS 1403 N. Research Way Orem, UT 84097 800.377.4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONEEXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE ANDUSE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSIONOF BLUE RAVEN SOLAR LLC.CUSTOMER INFORMATION:Nevil kabrawala7037 184 st westLakeville Minnesota 55044AC SYSTEM SIZE: 3.15 kW ACDC SYSTEM SIZE: 4.2 kW DCDRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: Brendan Fillmore October 27, 2023 886134 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 800-377-4480 PLACARD PV8 DIRECTORY PLACARD NOTES [NEC 705.10] A PERMANENT PLAQUE OR DIRECTORY DENOTING THE LOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ON OR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. THE MARKING SHALL COMPLY WITH [110.21(B)]. 1403 N. Research Way Orem, UT 84097 800.377.4480WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS Product Specifications ơexperience performance 9 A module Current compatible with MLPE wp430 20.7 w ft2 ELIGIBLE LEAD-FREE rohs cOMPLIANT22.3%Efficiency rec Alpha Pure-R SERIES COMPACT PANEL Size Ref: PD-DS-AAPR Rev 3.1 03.23 STC NMOT85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Lead-Free GR GR GR GR GR 11±0.2 [0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5 [0.8±0.02] 6.0±0.2[0.24±0.01] 1700 [67]1700 [67] Lorem ipsum 1730±2.5 [68.1±0.1] 880 [34.6]425 [16.7]1077±2.5 [42.4±0.1]22.5 [0.9] 594±3 [23.4±0.12] 1118±2.5 [44.0±0.1]17 [0.7]45 [1.8] 30 [1.2]REC Solar PTE. LTD. 20 Tuas South Ave. 14 Singapore 637312 post@recgroup.com www.recgroup.com Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. Available from: LOW LIGHT BEHAVIOUR Irradiance (W/m²)Rel. Efficiency (%)ELECTRICAL DATA Product Code *: RECxxxAA PURE-R Power Output - PMAX (Wp) 400 410 420 430 Watt Class Sorting - (W) 0/+10 0/+10 0/+10 0/+10 Nominal Power Voltage - VMPP (V) 48.8 49.4 50.0 50.5 Nominal Power Current - IMPP (A) 8.20 8.30 8.40 8.52 Open Circuit Voltage - VOC (V) 58.9 59.2 59.4 59.7 Short Circuit Current - ISC (A) 8.80 8.84 8.88 8.91 Power Density (W/ft2) 19.26 19.74 20.22 20.70 Panel Efficiency (%) 20.7 21.2 21.8 22.3 Power Output - PMAX (Wp) 305 312 320 327 Nominal Power Voltage - VMPP (V) 46.0 46.6 47.1 47.6 Nominal Power Current - IMPP (A) 6.64 6.70 6.80 6.88 Open Circuit Voltage - VOC (V) 55.5 55.8 56.0 56.3 Short Circuit Current - ISC (A) 7.11 7.16 7.20 7.24 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. REC Alpha PURE-R Series Product SPECIFICATIONS CERTIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance UL 61730 Fire Type 2 IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) IEC 62321 Lead-freeacc. to RoHS EU 863/2015 ISO 14001, ISO 9001, IEC 45001, IEC 62941 Measurements in inches [mm] GENERAL DATA Cell type:80 half-cut REC bifacial, heterojunction cells with lead-free, gapless technology Glass:0.13 in (3.2 mm) solar glass with anti-reflective surface treatment in accordance with EN 12150 Backsheet: Highly resistant polymer (black) Frame: Anodized aluminum (black) Junction box:4-part, 4 bypass diodes, lead-free IP68 rated, in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4 (12 AWG) in accordance with IEC 62852, IP68 only when connected Cable:12 AWG (4 mm²) PV wire, 67 + 67 in (1.7 + 1.7 m) in accordance with EN 50618 Dimensions: 68.1 x 44.0 x 1.2 in (20.77 ft 2) / 1730 x 1118 x 30 mm (1.93 m2) Weight: 47.4 lbs (21.5 kg) Origin: Made in Singapore Specifications subject to change without notice.Typical low irradiance performance of module at STC: DELIVERY INFORMATION Panels per pallet: 33 Panels per 40 ft GP/high cube container: 858 (26 pallets) Panels per 53 ft truck: 858 (26 pallets) WARRANTY Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98% 98% 98% Annual Degradation 0.25% 0.25% 0.25% Power in Year 25 92% 92% 92% See warranty documents for details. Conditions apply TEMPERATURE RATINGS* Nominal Module Operating Temperature: 44°C (±2°C) Temperature coefficient of PMAX:-0.24 %/°C Temperature coefficient of VOC:-0.24 %/°C Temperature coefficient of ISC:0.04 %/°C *The temperature coefficients stated are linear values MAXIMUM RATINGS Operational temperature: -40 ... +85°C System voltage: 1000 V Test load (front): + 7000 Pa (146lbs/ft 2)* Test load (rear): - 4000 Pa (83.5lbs/ft 2)* Series fuse rating: 25 A Reverse current: 25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) 1403 N. Research Way Orem, UT 84097 800.377.4480WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS The high-powered, smart grid-ready IQ7X MicroinverterHVEQEXMGEPP]WMQTPMƤIWXLI installation process while achieving the highest W]WXIQIJƤGMIRG]JSVW]WXIQW[MXLGIPPQSHYPIW Part of the Enphase Energy System, the IQ7X Microinverter integrates with the IQ Gateway, IQ Battery, and the Enphase Installer App monitoring ERHEREP]WMWWSJX[EVI The IQ Series Microinverters extend the reliability WXERHEVHWWIXJSVXLF]TVIZMSYWKIRIVEXMSRWERH YRHIVKSSZIVEQMPPMSRLSYVWSJTS[IVSRXIWXMRK IREFPMRK)RTLEWIXSTVSZMHIERMRHYWXV]PIEHMRK [EVVERX]SJYTXS]IEVW IQ7X Microinverter To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Microinverters Region: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014, 2017 & 2020) )JƤGMIRXERH6IPMEFPI • Optimized for high powered 96-cell* modules ŵ ,MKLIWX')'IJƤGMIRG]SJ • More than a million hours of testing • Class II double-insulated enclosure •UL listed 7QEVX+VMH6IEH] • Complies with advanced grid support, voltage and frequency ride-through requirements ŵ 6IQSXIP]YTHEXIWXSVIWTSRHXSGLERKMRK grid requirements ŵ 'SRƤKYVEFPIJSVZEV]MRKKVMHTVSƤPIW ŵ 1IIXW'%6YPI 907% ERH -))) 907&rd)H 8LI-5<MWVIUYMVIHXSWYTTSVXGIPPQSHYPIW IQ7X-DS-0099-EN-US-12-27-2022 4EMVMRK4:QSHYPIW[MXL[EXXEKIEFSZIXLIPMQMXQE]VIWYPXMREHHMXMSREPGPMTTMRKPSWWIW7IIXLIGSQTEXMFMPMX]GEPGYPEXSV at LXXTWPMROIRTLEWIGSQQSHYPIGSQTEXMFMPMX] 2SQMREPZSPXEKIVERKIGERFII\XIRHIHFI]SRHRSQMREPMJVIUYMVIHF]XLIYXMPMX]0MQMXWQE]ZEV]6IJIVXSPSGEPVIUYMVIQIRXWXSHIJMRIXLIRYQFIVSJQMGVSMRZIVXIVWTIVFVERGLMR]SYVEVIE To learn more about Enphase offerings, visit enphase.com k)RTLEWI)RIVK]%PPVMKLXWVIWIVZIH)RTLEWIXLI)RTLEWIPSKS-5-5-5&EXXIV])RTLEWI-RWXEPPIV%TT-5+EXI[E] ERHSXLIVXVEHIQEVOWSVWIVZMGIREQIWEVIXLIXVEHIQEVOWSJ)RTLEWI)RIVK]-RG INPUT DATA (DC) IQ7X-96-2-US Commonly used module pairings¹;; Module compatibility GIPP4:QSHYPIW 1E\MQYQMRTYX('ZSPXEKI : 4IEOTS[IVXVEGOMRKZSPXEKI :: Operating range :: 1MR1E\WXEVXZSPXEKI :: 1E\('WLSVXGMVGYMXGYVVIRX QSHYPI-WG 10A Overvoltage class DC port II ('TSVXFEGOJIIHGYVVIRX 0A 4:EVVE]GSRƤKYVEXMSR \YRKVSYRHIHEVVE]2SEHHMXMSREP('WMHITVSXIGXMSRVIUYMVIH %'WMHITVSXIGXMSRVIUYMVIWQE\%TIVFVERGLGMVGYMX OUTPUT DATA (AC)@ 240VAC @ 208VAC 4IEOSYXTYXTS[IV :% 1E\MQYQGSRXMRYSYWSYXTYXTS[IV :% 2SQMREP 00 ZSPXEKIVERKIs :: :: 1E\MQYQGSRXMRYSYWSYXTYXGYVVIRX % :%' % :%' Nominal frequency 60 Hz )\XIRHIHJVIUYIRG]VERKI ,^ %'WLSVXGMVGYMXJEYPXGYVVIRXSZIVG]GPIW %VQW 1E\MQYQYRMXWTIV% 00 FVERGLGMVGYMXt  :%'  :%' Overvoltage class AC port III %'TSVXFEGOJIIHGYVVIRX Q% 4S[IVJEGXSVWIXXMRK  4S[IVJEGXSV EHNYWXEFPI PIEHMRKPEKKMRK EFFICIENCY @240VAC @208VAC ')'[IMKLXIHIJƤGMIRG]   MECHANICAL DATA Ambient temperature range -40ºC to +60ºC 6IPEXMZILYQMHMX]VERKI  XS  GSRHIRWMRK Connector type (IQ7X-96-2-US)1' SV%QTLIRSP,98<[MXLSTXMSREP5(''EHETXIV (MQIRWMSRW ;\,\( QQ\QQ\QQ [MXLSYXFVEGOIX ;IMKLX OK PFW Cooling Natural convection - No fans Approved for wet locations Yes 4SPPYXMSRHIKVII 4( Enclosure Class II double-insulated, corrosion resistant polymeric enclosure )RZMVSRQIRXEPGEXIKSV]9:I\TSWYVIVEXMRK 2)1%8]TISYXHSSV FEATURES Communication 4S[IV0MRI'SQQYRMGEXMSR 40' Monitoring Enphase Installer App and monitoring options Compatible with IQ Gateway Disconnecting means 8LI%'ERH('GSRRIGXSVWLEZIFIIRIZEPYEXIHERHETTVSZIHF]90JSVYWIEWXLIPSEHFVIEOHMWGSRRIGXVIUYMVIHF]2)' Compliance '%6YPI 907% -))) 907&rd)H ,)-6YPI,76( 90*''4EVX'PEWW&-')7'PEWW&'%2'7%'23 8LMWTVSHYGXMW900MWXIHEW4:6ETMH7LYX(S[R)UYMTQIRXERHGSRJSVQW[MXL2)' 2)'ERH2)'WIGXMSRERH'6YPI6ETMH7LYXHS[RSJ4:7]WXIQWJSV%'ERH('GSRHYGXSVW[LIRMRWXEPPIHEGGSVHMRKQERYJEGXYVIVŭWMRWXVYGXMSRW IQ7X Microinverter IQ7X-DS-0099-EN-US-12-27-2022 DRAWING NUMBER:SS BLUE RAVEN SOLAR The Enphase Q Cable™ and accessories are part of the latest generation Enphase IQ System™. These accessories provide simplicity, reliability, and faster installation times. Enphase Q Cable Accessories To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Q Cable Accessories REGION: Americas Enphase Q Cable • Two-wire, double-insulated Enphase Q Cable is 50% lighter than the previous generation Enphase cable • New cable numbering and plug and play connectors speed up installation and simplify wire management • Link connectors eliminate cable waste Field-Wireable Connectors • Easily connect Q cables on the roof without complex wiring • Make connections from any open connector and center feed any section of cable within branch limits • Available in male and female connector types To learn more about Enphase offerings, visit enphase.com © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2020-06-26 CONDUCTOR SPECIFICATIONS 'IVXMƤGEXMSR UL3003 (raw cable), UL 9703 (cable assemblies), DG cable Flame test rating FT4 Compliance RoHS, OIL RES I, CE, UV Resistant, combined UL for Canada and United States Conductor type THHN/THWN-2 dry/wet Disconnecting means The AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Q CABLE TYPES / ORDERING OPTIONS Connectorized Models Size / Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q-12-10-240 12 AWG / 277 VAC 1.3 m (4.2 ft) Portrait 240 Q-12-17-240 12 AWG / 277 VAC 2.0 m (6.5 ft) Landscape (60-cell) 240 Q-12-20-200 12 AWG / 277 VAC 2.3 m (7.5 ft) Landscape (72-cell) 200 ENPHASE Q CABLE ACCESSORIES Name Model Number Description Raw Q Cable Q-12-RAW-300 300 meters of 12 AWG cable with no connectors Field-wireable connector (male)Q-CONN-10M Make connections from any open connector Field-wireable connector (female)Q-CONN-10F Make connections from any Q Cable open connector Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Disconnect tool Q-DISC-10 Disconnect tool for Q Cable connectors, DC connectors, and AC module mount Q Cable sealing caps (female)Q-SEAL-10 One needed to cover each unused connector on the cabling Terminator Q-TERM-10 Terminator cap for unused cable ends Enphase EN4 to MC4 adaptor¹ECA-EN4-S22 Connect PV module using MC4 connectors to IQ micros with EN4 (TE PV4-S SOLARLOK). 150mm/5.9” to MC4. Enphase EN4 non-terminated adaptor¹ECA-EN4-FW *SVƤIPH[MVMRKSJ90GIVXMƤIH('GSRRIGXSVW)2 8)4:7730%603/ XSnon-terminated cable. 150mm/5.9” Enphase EN4 to MC4 adaptor (long)¹ECA-EN4-S22-L Longer adapter cable for EN4 (TE PV4-S SOLARLOK) to MC4. Use with split cell modules or PV modules with short DC cable. 600mm/23.6” Replacement DC Adaptor (MC4)Q-DCC-2 DC adaptor to MC4 (max voltage 100 VDC) Replacement DC Adaptor (UTX)Q-DCC-5 DC adaptor to UTX (max voltage 100 VDC) 1. 5YEPMƤIHTIV90WYFNIGX Enphase Q Cable Accessories TERMINATOR Terminator cap for unused cable ends, sold in packs of ten (Q-TERM-10) SEALING CAPS Sealing caps for unused aggregator and cable connections (Q-BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL Plan to use at least one per installation, sold in packs of ten (Q-DISC-10) CABLE CLIP Used to fasten cabling to the racking or to secure looped cabling, sold in packs of one hundred (Q-CLIP-100) 1403 N. Research Way Orem, UT 84097 800.377.4480WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. SHEET NAME: PAGE NUMBER:REVISION: 0 CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEETS SS 1403 N. Research Way Orem, UT 84097 800.377.4480WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS 125 & 200 Amp 011 (closed)U204 (open)Single Meter Sockets Without Bypass Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Single Meter Sockets - Without Bypass Application • Single meter position • Receive ANSI C12.10 watthour meters • Surface or flush mount (see chart) Construction • Ring type • NEMA Type 3R • ANSI 61 gray painted finish • Aluminum snap ring included Standards Accessories • UL 414 Listed • 5th Jaw Kit - see chart • ANSI C12.7 • AW Hub 4 B-Line series meter mounting equipmentEaton Part/UPC Number Catalog Number Amp Rating Jaws Service Type Access Connections Overall Dimensions Top Provision Knockout Layout 5th Jaw KitLine Load Neutral Height Width Depth 78205142000 011 125 4 1Ø/3W OH/UG #8 - 2/0 #8 - 2/0 #8 - 2/0 11" 8 1/4"35/8" AW Hub Fig.5 MSR5TK 78205142040 011 F 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 12" 8" 4 5/8" 2" max KO Fig. 1 50365 78205142045 011 MS73 125 4 1Ø/3W OH/UG #8 - 2/0 #8 - 2/0 #8 - 2/0 11" 8 1/4"35/8" AW Hub Fig. 5 MSR5TK 78205142050 011 SF 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 12" 8" 4 5/8" None None 50365 78205102315 011 SS 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 12" 8" 4 5/8" None None 50365 79903882585 011 SS6 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 12" 8" 4 5/8" None None 50365 79903882586 011 MS25A 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 12" 8" 4 5/8" AW Hub Fig. 1 50365 79903856283 011 MS25 125 4 1Ø/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 12" 8" 4 5/8" AW Hub Fig. 1 50365 79903868944 011 MS-18 125 4 1Ø/3W OH/UG #8 - 2/0 #8 - 2/0 #8 - 2/0 11" 8 1/4"35/8" AW Hub Fig.5 MSR5TK 79903878861 011 SRP 125 4 1Ø/3W OH/UG #8 - 2/0 #8 - 2/0 #8 - 2/0 11" 8 1/4"35/8" AW Hub Fig.5 MSR5TK 79903878953 011 SRP MS18 125 4 1Ø/3W OH/UG #8 - 2/0 #8 - 2/0 #8 - 2/0 11" 8 1/4"35/8" AW Hub Fig.5 MSR5TK 78205144030 927 100 7 3Ø/4W OH/UG #14 - 1/0 #14 - 2/0 #14 - 2/0 17" 8" 4 5/8" AW Hub Fig. 1 50365 78205156000 204 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 8" 4 5/8" AW Hub Fig. 2 50365 78205156020 204 F 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 8" 6" 2" max KO Fig. 2 50365 78205108796 204 SS 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 8" 6" None None 50365 79903882318 U204 PSE 200 4 1Ø/3W UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 12" 6" None Fig. 7 50365 78205122640 U204 F SS 200 4 1Ø/3W UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 12" 6" None None 50365 78205134301 U204 SS 200 4 1Ø/3W UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 12" 6" None None 50365 78205153193 U204 MS73 SS 200 4 1Ø/3W UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 12" 6" None None 50365 78205156080 U204 MS21 SS 200 4 1Ø/3W UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 12" 6" None None 50365 78205156030 204 F MS73 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 8" 6" 2" max KO Fig. 2 50365 78205156040 204 MS68 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 8" 4 5/8" AW / 2" Hub Fig. 2 50365 78205156035 204 MS68A 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 8" 4 5/8" AW / 2" Hub Fig. 2 50365 78205108490 204 MS73 200 4 1Ø/3W OH #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 8" 4 5/8" AW Hub Fig. 2 50365 78205156005 U204 200 4 1Ø/3W UG #6 - 350MCM #6 - 350MCM #6 - 350MCM 15 1/8"111/4"41/2" None Fig. 6 MSR5TK 78205156045 U204 F 200 4 1Ø/3W OH/UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 12" 6" (2) 2" max KO Fig. 3 50365 78205156060 U204 MS21 200 4 1Ø/3W OH/UG #6 - 350MCM #6 - 350MCM #6 - 350MCM 15 1/8"111/4"41/2" AW / Cap Fig. 6 MSR5TK 78205156060 U204 F MS73 200 4 1Ø/3W UG #6 - 250MCM #6 - 350MCM #6 - 350MCM 15" 12" 6" None Fig. 3 50365 78205156070 U204 MS73 200 4 1Ø/3W OH/UG #6 - 350MCM #6 - 350MCM #6 - 350MCM 15 1/8"111/4"41/2" (2) 2" max KO Fig. 6 MSR5TK 78205156140 U207 200 7 3Ø/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM 18" 12" 5" AW Hub Fig. 4 50365 78205156170 U207 F 200 7 3Ø/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM 18" 12" 5" 2 1/2" max KO Fig. 4 50365 78205156180 U207 MS73 200 7 3Ø/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM 18" 12" 5" AW Hub Fig. 4 50365 Knockouts - Conduit Sizes 1W = 1⁄4" 1A = 1⁄2" 2A = 1⁄2" - 1⁄4" 4D = 11⁄4" - 1" - 3⁄4" - 1⁄2" 4E = 11⁄2" - 11⁄4" - 1" - 3⁄4" 4F = 2" - 11⁄2" - 11⁄4" - 1" 4G = 21⁄2" - 2" - 11⁄2" - 11⁄4" 4H - 3" - 21⁄2" - 2" - 11⁄2" 6G = 21⁄2" - 2" - 11⁄2" - 11⁄4" - 1" - 3⁄4" Top Provision = See Chart Knockout Layouts 125 & 200 Amp Single Meter Sockets Without Bypass Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Single Meter Sockets - Without Bypass Style #Suffixes 011 F - Flush Mount (U) 207 MS18 - Lexan Cover (U) 204 MS21 - Top Hub Provision (U) 207 MS25 - Solar Ready (U) 207 MS25A - MS25 + MS18 927 MS68 - 2" Conduit Hub MS68A - MS73 + MS68 MS73 - AL Screw Type Ring SF - Semi Flush Mount SS - Stainless Steel 304 * SS6 - Stainless Steel 316 * 5B-Line series meter mounting equipment Eaton * Knockouts and top provisions are not available in Stainless Steel (SS) finish Fig. 1 Fig. 6 Top Provision Top Provision Fig. 2 Fig. 4 2A Top ProvisionTop Provision 1A 4F 4F 4Fbothsides 1A 6G 4G 4G 1W 4G 4G 4G4G 4G 6Gbothsides4Gbothsides 1A 4F 4F 4Fbothsides Fig. 3 Top Provision 1W 4F 4G 4G 4F 4Fbothsides Fig. 5 Top Provision 1A 4E 4F 4Ebothsides 4D4D Fig. 7 Top Provision 1A 4F 4H 4F 4G 4Fbothsides 1403 N. Research Way Orem, UT 84097 800.377.4480WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SSPROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EZ SOLAR. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. Phone: 385-202-4150 www.ezsolarproducts.com ITEM No. 1 1 1 6 6 JB-1.2 Body POLYCARBONATE WITH UV INHIBITORS POLYCARBONATE WITH UV INHIBITORS #10 x 1-1/4” Phillips pan head screw #8 x 3/4” Phillips pan head screw JB-1.2 Lid2 3 4 PART NUMBER DESCRIPTION QTY Size SCALE: 1:2 WEIGHT: 1.45 LBS SHEET 1 of 3 DWG. NO. Rev B JB-1.2 Torque Specification: certification: WEIGHT: 15-20 LBS 1.45 LBS UL Standard 1741, nema 3r JB-1.2 Specification Sheet PV Junction Box for Composition/Asphalt Shingle Roofs • Maximum Voltage: 1,000 Volts • Maximum Current: 80 Amps • Allowable Wire: 14 AWG – 6 AWG • Spacing: Please maintain a spacing of at least ½” between uninsulated live parts and fittings for conduit, armored cable, and uninsulated live parts of opposite polarity. • Enclosure Rating: Type 3R • Roof Slope Range: 2.5 – 12:12 • Max Side Wall Fitting Size: 1” • Max Floor Pass-Through Fitting Size: 1” • Ambient Operating Conditions: (-35°C) - (+75°C) • Compliance: - JB-1.2: UL1741 - Approved wire connectors: must conform to UL1741 • System Marking: Interek Symbol and File #5019942 • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion between components, components that are found to be affected are to be replaced immediately. A. System Specifications and Ratings Phone: 385-202-4150 | www.ezsolarproducts.com 1403 N. Research Way Orem, UT 84097 800.377.4480WWW.BLUERAVENSOLAR.COM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. DRAWING BY: PLOT DATE: PROJECT NUMBER: SHEET NAME: PAGE NUMBER:REVISION: ---- CERTIFIED NABCEP PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 CONTRACTOR: BRS FIELD OPS 385-498-6700 SPEC SHEET SS www.carlon.com180 Rigid Nonmetallic Conduit – Junction Boxes Molded Nonmetallic Junction Boxes6P Rated It’s another first from Carlon®- the first nonmetallic junction boxes UL Listed with a NEMA 6P rating per Section 314.29, Exception of the National Electrical Code. Manufactured from PVC or PPO thermoplastic molding compound and featuring foam-in-place gasketed lids attached with stainless steel screws, these rugged enclosures offer all the corrosion resistance and physical properties you need for direct burial applications. Type 6P enclosures are intended for indoor or outdoor use, primarily to provide a degree of protection against contact with enclosed equipment, falling dirt, hose- directed water, entry of water during prolonged submersion at a limited depth, and external ice formation. • All Carlon Junction Boxes are UL Listed and maintain a minimum of a NEMA Type 4/4x Rating. • Parts numbers with an asterisk (*) are UL Listed and maintain a NEMA Type 6P Rating and Type 4/4X Rating. E42728Except where noted by † Size in Std.Material Std. Inches Ctn. Min Min. Min. Min. Ta Tc Thermo-Ctn. Part No. H x W x D Qty.AT AB B C PVC plastic Wt. (Lbs.) E989NNJ-CAR* 4 x 4 x 2 5 311/16 35/8 N/A 2 .160 .155 X 3 E987N-CAR* 4 x 4 x 4 5 3 11/16 31/2 N/A 4 .160 .155 X 4 †E989NNR-CAR* 4 x 4 x 6 4 3 11/16 33/8 N/A 6 .160 .200 X 5 E989PPJ-CAR* 5 x 5 x 2 4 411/16 41/2 N/A 2 .110 .150 X 3 E987R-CAR* 6 x 6 x 4 2 6 5 5/8 N/A 4 .190 .190 X 3 E989RRR-UPC* 6 x 6 x 6 8 5 5/8 53/8 N/A 6 .160 .150 X 14 E989N-CAR 8 x 8 x 4 1 8 8 N/A 4 .185 .190 X 2 E989SSX-UPC 8 x 8 x 7 2 7 21/32 75/16 N/A 7 .160 .150 X 6 E989UUN 12 x 12 x 4 3 115/8 111/2 111/8 4 .160 .150 X 12 E989R-UPC 12 x 12 x 6 2 11 15/16 117/8 117/16 6 .265 .185 X 10 Typical Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com DRAWING NUMBER:SS BLUE RAVEN SOLAR SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR WITH BENEFITS ACROSS YOUR BUSINESS, FROM DESIGN AND LOGISTICS, THROUGH ARRAY INSTALLATION AND SERVICE. SFM INFINITY 20% FEWER ATTACHMENTS Save time and money on every project: SFM INFINITY requires fewer attachments than rail systems. 2 INSTALLS PER DAY Make two installs per day your new standard. SFM INFINITY has fewer roof attachments, one tool installation, and pre-assembled components to get you off the roof 40% faster. BETTER AESTHETICS Install the system with the aesthetics preferred by homeowners, with integrated front trim, trim end caps, dark components, and recessed hardware. 30% LOGISTICS SAVINGS With fewer SKUs and compact components, SFM INFINITY is easier to stock, easier to transport, and easier to lift to the roof. Plus, make more efficient use of your vehicle fleet. SYSTEM OVERVIEW BONDING AND ACCESSORIES 2MW 3MW PART NAME DESCRIPTION TRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules N/S BONDING CLAMP Electrically bonds rows of modules 2 3 4 5 6 1 1 4 3 5 6 7 SFM INFINITY 15 Attachments RAIL 20 Attachments 87%OF HOMEOWNERS PREFER MAXIMUM POWER DENSITY Easily mix module orientations to achieve optimal power density without incurring the increased bill of materials, labor, and attachments required by rail. 7 2 PART NAME DESCRIPTION TRIMRAIL Structural front trim provides aesthetic and aligns modules. TRIMRAIL SPLICE Connects and electrically bonds sections of TRIMRAIL. TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof. Available for comp shingle or tile. MODULE CLIPS Secure modules to TRIMRAIL. MICRORAIL Connects modules to SLIDERS. Provides post-install array leveling. SPLICE Connects and supports modules. Provides east-west bonding. ATTACHED SPLICE also available. SLIDER FLASHKIT Roof attachment and flashing. Available for comp shingle and tile. DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE 8FLASHKIT MOUNTING PILOT HOLES: 'ULOOSLORWKROHVIRUODJVFUHZVRU VWUXFWXUDOVFUHZV DVQHFHVVDU\ DW PDUNHGDWWDFKPHQWSRLQWV FLASHINGS: 3ODFHʴDVKLQJV Ô INSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS: • ,QVHUWʴDVKLQJVSHUPDQXIDFWXUHULQVWUXFWLRQV NOTE: Use Lag screw or structural fastener with a maximum diameter of 5/16" • $WWDFKVOLGHUVWRUDIWHUV • 9HULI\SURSHUURZWRURZVSDFLQJIRUPRGXOHVL]H 0RG16 • (QVXUHWKDW7ULPUDLOȺURRIDWWDFKPHQWVLQHDFKURZKDYHVXIʳFLHQW  HQJDJHPHQWZLWKVOLGHUGRYHWDLOVIRUSURSHUDWWDFKPHQW INSTALL SLIDERS AND ROOF ATTACHMENTS: )ROORZPDQXIDFWXUHULQVWUXFWLRQV IRUʴDVKLQJLQVWDOODWLRQSURFHGXUHV NOTE: If N-S module edge is within 1” of the shingle course above, you have the option to pivot / rotate slider at the attachment point to span the next course and cut shingles as required. ×UP-SLOPE DOWN-SLOPE × Mod NS + 1" Mod NS + 1" N/S MODULE EDGE Rotate Slider Cut Shingles as Required Less Than 1" DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE 11TRIMRAIL & MICRORAIL INSTALLATION ATTACH TRIMRAIL TO ROOF ATTACHMENT: $WWDFKUDLOXVLQJKH[EROW 7ULGULYHRU VHUUDWHGʴDQJHQXWV0DNHVXUH7ULPUDLOTM is OHYHODFURVVDOO7ULPUDLOTMURRIDWWDFKPHQWV $IWHUUDLOLVOHYHOWLJKWHQFKDQQHOFODPS EROWVWRVHFXUH7ULPUDLOTM URRIDWWDFKPHQWV WRFKDQQHOV POSITION MODULE CLIPS ACCORDING TO MODULE THICKNESS: $OLJQQRWFKLQPRGXOHFOLSZLWKWULPUDLOULE DFFRUGLQJWRPRGXOHWKLFNQHVV LGHQWLʳHGLQ PPRQIDFHVRIPRGXOHFOLSV 5RWDWHFOLSWR SRVLWLRQDWUHTXLUHGORFDWLRQ INSTALL MODULE CLIPS ON TRIMRAIL: $WWDFKPRGXOHFOLSVWR7ULPUDLOXVLQJ 7EROWVDQG7ULGULYHRUVHUUDWHGʴDQJHQXWV$ PLQLPXPRIWZRFOLSVDUHUHTXLUHGSHUPRGXOH 5HIHUWR6)0' (JXLGHDQG8EXLOGHUIRU UHTXLUHGSRVLWLRQDQGTXDQWLW\RIPRGXOHFOLSV INSTALL MICRORAILS: ,QVWDOO0LFURUDLOTMDWPDUNHGDWWDFKPHQWSRLQWV&OLFN MicrorailTMLQWRVOLGHUVDQGSXVK0LFURUDLOTMWRWRSRIVOLGHU (QVXUHWKDWFDSUHPDLQVLQXSSHUPRVW PP SRVLWLRQ NOTE: module clips may be pre-installed on trimrail prior to attaching trimrail to roof attachments NOTE: Bonding pin on Microrails should be positioned downslope.Ñ%21',1*3,1 ÑÑÑÑ Ñ DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE 19SYSTEM BONDING & GROUNDING E-W BONDING PATH: (:PRGXOHWRPRGXOHERQGLQJLVDFFRPSOLVKHG ZLWKSUHLQVWDOOHGERQGLQJSLQVZKLFKHQJDJH RQWKHVHFXUHVLGHRIWKH0LFURUDLO70DQGVSOLFH TRIMRAIL BONDING PATH: 7ULPUDLOWRPRGXOHERQGLQJLVDFFRPSOLVKHGZLWK ERQGLQJFODPSZLWKLQWHJUDOERQGLQJSLQDQG ERQGLQJ7EROW(refer also to alternate method) N-S BONDING PATH: 16PRGXOHWRPRGXOHERQGLQJLV DFFRPSOLVKHGZLWKERQGLQJFODPSZLWKLQWHJUDO ERQGLQJSLQV(refer also to alternate method) System bonding is accomplished through modules. System grounding accomplished by attaching DJURXQGOXJWRDQ\PRGXOHDWDORFDWLRQRQWKHPRGXOHVSHFLʳHGE\WKHPRGXOHPDQXIDFWXUHU LUG DETAIL & TORQUE INFO Ilsco Lay-In Lug (GBL-4DBT) • PRXQWLQJKDUGZDUH • 7RUTXH IWOE • $:*6ROLGRU6WUDQGHG LUG DETAIL & TORQUE INFO Ilsco Flange Lug (SGB-4) • ȧPRXQWLQJKDUGZDUH • 7RUTXH LQOE • $:*6ROLGRU6WUDQGHG LUG DETAIL & TORQUE INFO Wiley WEEBLug (6.7) • ȧPRXQWLQJKDUGZDUH • 7RUTXH IWOE • $:*6ROLGRU6WUDQGHG NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION TERMINAL TORQUE, Install Conductor and torque to the following: 4-6 AWG: 35in-lbs 8 AWG: 25 in-lbs 10-14 AWG: 20 in-lbs TERMINAL TORQUE, Install Conductor and torque to the following: 6-14 AWG: 7ft-lbs TERMINAL TORQUE, Install Conductor and torque to the following: 4-14 AWG: 35in-lbs WEEBLUG Single Use Only Star Washer is Single Use Only Ñ$OWHUQDWHPHWKRG $OWHUQDWHPHWKRG DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE 20UL CODE COMPLIANCE NOTES SYSTEM LEVEL FIRE CLASSIFICATION 7KHV\VWHPʳUHFODVVUDWLQJUHTXLUHVLQVWDOODWLRQLQWKHPDQQHUVSHFLʳHGLQWKH 681)5$0(0,&525$,/ 6)0 ,QVWDOODWLRQ*XLGH6)0KDVEHHQFODVVLʳHGWR WKHV\VWHPOHYHOʳUHSRUWLRQRI8/7KLV8/FODVVLʳFDWLRQKDVEHHQ LQFRUSRUDWHGLQWRWKH8/SURGXFWFHUWLʳFDWLRQ6)0KDVDFKLHYHG&ODVV$ % &V\VWHPOHYHOSHUIRUPDQFHIRUORZVORSH VWHHSVORSHGURRIVZKHQXVHG LQFRQMXQFWLRQZLWKW\SHDQGW\SHPRGXOHV&ODVV$% &V\VWHPOHYHOʳUH UL2703 TEST MODULES 6HHSDJHVDQGIRUDOLVWRIPRGXOHVWKDWZHUHHOHFWULFDOO\DQGPHFKDQLFDOO\WHVWHGRU TXDOLʳHGZLWKWKH681)5$0(0,&525$,/ 6)0 FRPSRQHQWVRXWOLQHGZLWKLQWKLV,QVWDOODWLRQ*XLGH •0D[LPXP$UHDRI0RGXOH VTIW •8/'HVLJQ/RDG5DWLQJV D 'RZQZDUG3UHVVXUHȡ36)3D E 8SZDUG3UHVVXUHȡ36)3D F 'RZQ6ORSH/RDGȡ36)3D •7HVWHG/RDGV D 'RZQZDUG3UHVVXUHȡ36)3D E 8SZDUG3UHVVXUHȡ36)3D F 'RZQ6ORSH/RDGȡ36)3D •0D[LPXP6SDQ IW •8VHZLWKDPD[LPXPRYHUFXUUHQWSURWHFWLRQGHYLFH2&3'RI$ •6\VWHPFRQIRUPVWR8/6WGFHUWLʳHGWR/75$( •5DWHGIRUDGHVLJQORDGRI3D3DZLWKLQFKVSDQ •39PRGXOHVPD\KDYHDUHGXFHGORDGUDWLQJLQGHSHQGHQWRIWKH6)0ORDGUDWLQJ3OHDVHFRQVXOW WKH39PRGXOHPDQXIDFWXUHU VLQVWDOODWLRQJXLGHIRUPRUHLQIRUPDWLRQ •'RZQ6ORSHGHVLJQORDGUDWLQJRI36)3DIRUPRGXOHDUHDVRIVTIWRUOHVV Module Type Roof Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation Required Type 1 and Type 2 6WHHS6ORSH /RZ6ORSH &ODVV$% & (DVW:HVW /DQGVFDSH253RUWUDLW None Required SHUIRUPDQFHLVLQKHUHQWLQWKH6)0GHVLJQDQGQRDGGLWLRQDOPLWLJDWLRQPHDVXUHV DUHUHTXLUHG7KHʳUHFODVVLʳFDWLRQUDWLQJLVYDOLGIRUDQ\URRISLWFK7KHUHLVQR UHTXLUHGPLQLPXPRUPD[LPXPKHLJKWOLPLWDWLRQDERYHWKHURRIGHFNWRPDLQWDLQ WKH&ODVV$% &ʳUHUDWLQJIRU6)0681)5$0(0,&525$,/TM FRPSRQHQWVVKDOO EHPRXQWHGRYHUDʳUHUHVLVWDQWURRIFRYHULQJUDWHGIRUWKHDSSOLFDWLRQ DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE 21UL CODE COMPLIANCE NOTES LABEL MARKINGS •6\VWHPʳUHFODVVUDWLQJ6HHLQVWDOODWLRQLQVWUXFWLRQVIRULQVWDOODWLRQUHTXLUHPHQWVWRDFKLHYHDVSHFLʳHGV\VWHPʳUHFODVVUDWLQJZLWK8QLUDF •8QLUDF681)5$0(0,&525$,/TMLVOLVWHGWR8/ •$OOVSOLFHVZLWKLQDV\VWHPDUHVKLSSHGZLWKPDUNLQJLQGLFDWLQJGDWHDQGORFDWLRQRIPDQXIDFWXUH DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE 22TESTED / CERTIFIED MODULE LIST Aleo P-Series $SWRV '1$ %)0)  '1$ %)0)  $VWURQHUJ\ &+603&+603+9&+600 &+600+9&+600 %/ %)  +)  CHSM72M-HC Auxin $;107$;137 $;107 $;137 $[LWHF $;,EODFNSUHPLXP PP  $;,SRZHU PP  $;,SRZHU PP  $;,SUHPLXP PP  $;,SUHPLXP PP  %RYLHW %90 %90 %<'P6K & MHK-36 Series Canadian Solar &6 +.8< 06 &6 ./8 &6.0%$*&6. 063 &6106&680%$*&68 063 &6: &6$0&6 .8 &6. 03 &6.06 &63 03 &68 03 &690&6;3 &HQWURVRODU$PHULFD C-Series & E-Series &HUWDLQ7HHG &7[[0[[&7[[3[[ &7[[[0[[&7[[[0 &7[[[0[[&7[[[+& 'HKXL '+0 Manufacture Module Model / Series Eco Solargy Orion 1000 & Apollo 1000 ET Solar ET-M672BHxxxTW )UHHGRP)RUHYHU FF-MP-BBB-370 )UHH9ROW Mono PERC GCL GCL-P6 & GCL-M6 Series Hansol 7'$17'$1 8%$18'$1 Heliene 0030 36HULHV +&00RQRIDFLDO%LIDFLDO6HULHV +&06/%LIDFLDO HT Solar +7 0  1'9  )  +7 03 Hyundai .*0*7*5,5*7,0,+, .,6HULHV HiA-SxxxHG ,7(. L7L7+( L76(6HULHV Japan Solar JPS-60 & JPS-72 Series JA Solar -$3[[[-$0[[[6,-$0 .  [[[-$3 N [[[%%-$36<<[[[== -$3 N [[[%%-$36<<[[[== -$0 N [[[==-$06<<[[[== -$0 N [[[==-$06<<[[[== L<< LL==6&35%3+L7,%0:05 -LQNR JKM & JKMS Series Eagle JKMxxxM -.0[[[0+/9 Kyocera KU Series Manufacture Module Model / Series Manufacture Module Model / Series ȫ8QOHVVRWKHUZLVHQRWHGDOOPRGXOHVOLVWHGDERYHLQFOXGHDOOZDWWDJHVDQGVSHFLʳFPRGHOVZLWKLQWKDWVHULHV9DULDEOHZDWWDJHVDUHUHSUHVHQWHGDV[[[ ȫ,WHPVLQSDUHQWKHVLVDUHWKRVHWKDWPD\RUPD\QRWEHSUHVHQWLQDFRPSDWLEOHPRGXOH VPRGHO,' ȫ6ODVKHVEHWZHHQRQHRUPRUHLWHPVLQGLFDWHVWKDWHLWKHURIWKRVHLWHPVPD\EHWKHRQHWKDWLVSUHVHQWLQDPRGXOH VPRGHO,' ȫ3OHDVHVHHWKH6)08/&RQVWUXFWLRQ'DWD5HSRUWDW8QLUDFFRPWRHQVXUHWKHH[DFWVRODUPRGXOHVHOHFWHGLVDSSURYHGIRUXVHZLWK6)0 ȫ6)0,QʳQLW\LVQRWFRPSDWLEOHZLWKPRGXOHIUDPHKHLJKWRIOHVVWKDQPPDQGPRUHWKDQPP6HH0RGXOH0RXQWLQJVHFWLRQSDJHIRUIXUWKHULQIRUPDWLRQ /*(OHFWURQLFV LGxxxN2T-A4 /*[[[ $&(&(.1&1.171: 4&4.6&6: $ LGxxxN2T-B5 LGxxxN1K-B6 /*[[[ $&0&0.1&1.4&4. 4$&4$. $ /*[[[ 1&1.171: ( /*[[[ 1&1.1:6&6: * LGxxxN2T-J5 /*[[[ 1.1:171: / /*[[[ 1&4&4. 1 /*[[[ 1&1.1:4&4. 9 LONGi /5 +,%+,++3%+3+ [[[0 /5 +,++3+ [[[0 /5 %3+%'+,%' [[[0 PP /5 %. 3( +3% +3+ [[[0 PP /5 %. 3( 3% 3+ [[[0 PP /5 %3 +%' +,%' [[[0 PP /5 +9 %. 3( 3+ 3% +3+ [[[0 PP /5 %. +9 3( 3% 3+ [[[0 PP Mission Solar Energy MSE Series 0LWVXELVKL MJE & MLE Series 1HR6RODU3RZHU&R '0 '36HULHV DRAWING NUMBER:SS BLUE RAVEN SOLARSFMSUN FRAME MICRORAIL™INSTALLATION GUIDE PAGE 23TESTED / CERTIFIED MODULE LIST 5(&6RODU FRQW 7ZLQ3HDN6HULHV 7ZLQ3HDN6HULHV 7ZLQ3HDN%/.6HULHV 7ZLQ3HDN6 0  ;9  7ZLQ3HDN6HULHV PP 73 %ODFN Renesola 9LWUXV6HULHV 6HULHV Risen 560 0'*  0 560 SEG Solar 6(*[[[%0'+9 6(*[[[%0'7% S-Energy 61 616HULHV PP Seraphim SEG-6 & SRP-6 Series Sharp NU-SA & NU-SC Series 6LOIDE 6/$6/*%&6HULHV 6,/[[[ %/1/17+/ 0/%.1;18+&  6RODUHYHU86$ 6( [[[01 Solaria 3RZHU;7[[[5 $&3'%' 3RZHU;7[[[&3' 3RZHU;7[[[530 $& SolarWorld 6XQPRGXOH3URWHFW Sunmodule Plus Sonali 660WR6HULHV 660WR6HULHV 660WR6HULHV 660WR%L)DFLDO6HULHV SS 230 - 265 SunEdison )6HULHV56HULHV )/(;);66HULHV Manufacture Module Model / Series 6XQLYD 096HULHV 2SWLPXV6HULHV SunPower $6HULHV$%/.6350$;;;;5 ;6HULHV(6HULHV 36HULHV 6XQWHFK 673673;;;6%:QKE Talesun 73737373 73+LSRU06PDUW Tesla 6&6&%6&%6&% 7[[[+7[[[6 Trina 3$3''''(''3( 3'3('''('('( PE15H Upsolar 830[[[3 %  830[[[0 % 8QLWHG5HQHZDEOH(QHUJ\ 85( '0[[[+$' 0. [[[+$ )$.[[[ &*(* )$0[[[(*%% )$0[[[(* %% FBMxxxMFG-BB 9LNUDP (OGRUD 6ROLYR Somera Waaree AC & Adiya Series Winaico WST & WSP Series Yingli YGE & YLM Series =16KLQH =;0=;01+B Manufacture Module Model / Series Manufacture Module Model / Series ȫ8QOHVVRWKHUZLVHQRWHGDOOPRGXOHVOLVWHGDERYHLQFOXGHDOOZDWWDJHVDQGVSHFLʳFPRGHOVZLWKLQWKDWVHULHV9DULDEOHZDWWDJHVDUHUHSUHVHQWHGDV[[[ ȫ,WHPVLQSDUHQWKHVLVDUHWKRVHWKDWPD\RUPD\QRWEHSUHVHQWLQDFRPSDWLEOHPRGXOH VPRGHO,' ȫ6ODVKHVEHWZHHQRQHRUPRUHLWHPVLQGLFDWHVWKDWHLWKHURIWKRVHLWHPVPD\EHWKHRQHWKDWLVSUHVHQWLQDPRGXOH VPRGHO,' ȫ3OHDVHVHHWKH6)08/&RQVWUXFWLRQ'DWD5HSRUWDW8QLUDFFRPWRHQVXUHWKHH[DFWVRODUPRGXOHVHOHFWHGLVDSSURYHGIRUXVHZLWK6)0 ȫ6)0,QʳQLW\LVQRWFRPSDWLEOHZLWKPRGXOHIUDPHKHLJKWRIOHVVWKDQPPDQGPRUHWKDQPP6HH0RGXOH0RXQWLQJVHFWLRQSDJHIRUIXUWKHULQIRUPDWLRQ Panasonic (939[[[ +.3.  9%+1[[[6$ 6$ 9%+1[[[6$ 6$ 9%+1[[[6$ (*  6$( 9%+1[[[.$ .$ .$ 9%+1[[[=$9%+1[[[=$ 9%+1[[[=$9%+1[[[=$ Peimar 6*[[[0 )%%) Phono Solar 3636 Prism Solar P72 Series 4&HOOV 3OXV3UR3HDN****  **  3UR3HDN/*/*/*/*/* 43($.'82%/.* 43($.'82%/.*76 43($.'82 %/. *  43($.'82/*%)) 43($.'82 %/. 0/*  43($.'82;/*** 43($.'82 %/. 0/*  43($.'82;/* FG 43($.'82%/.0/*W REC Solar $OSKD   %ODFN  3XUH RECxxxAA PURE-R 5(&[[[13%ODFN 13HDN %ODFN 13HDN %ODFN PEAK Energy Series PEAK Energy BLK2 Series PEAK Energy 72 Series 6+((71$0( 3$*(180%(5 5(9,6,21 &21),'(17,$/7+(,1)250$7,21 +(5(,1&217$,1('6+$//127%( 86(')257+(%(1(),72) $1<21((;&(37%/8(5$9(1 62/$51256+$//,7%( ',6&/26(',1:+2/(25,13$57 7227+(562876,'(5(&,3,(176 25*$1,=$7,21(;&(37,1 &211(&7,21:,7+7+(6$/($1' 86(2)7+(5(63(&7,9( (48,30(17:,7+2877+( :5,77(13(50,66,212)%/8( 5$9(162/$5//& 66 63(&6+((7  &2175$&725 %56),(/'236  39,167$//$7,21 352)(66,21$/6FRWW*XUQH\ 39 1$%&(3 &(57,),(' 15(6($5&+:$<%8,/',1*- 25(087  :::%/8(5$9(162/$5&20 ___________________________________________________________________________________________ Domus Structural Engineering, LLC P.O. Box 560 Broomfield, CO 80038 530-864-7055 projects@domusstruc.com To: Blue Raven Solar 1403 North Research Way, Building J Orem, UT. 84097 Subject: Certification Letter Kabrawala Residence 7037 184th St W Lakeville, MN. 55044 To Whom It May Concern, Design Criteria: භ Applicable Codes = 2018 IBC/IRC, ASCE 7-16 භ Roof Dead Load = 7 psf (MP1) භ Roof Live Load = 20 psf භ Wind Speed = 115 mph (Vult), Exposure C භ භ Sincerely, John Calvert, P.E. Project Engineer October 27, 2023 The roof structure of (MP1) consists of composition shingle on roof plywood that is supported by pre-manufactured trusses that are spaced at @ 24"o.c.. The top chords, sloped at 27 degrees, are 2x4 sections, the bottom chords are 2x4 sections and the web members are 2x4 sections. The truss members are connected by steel gusset plates. The max unsupported projected horizontal top chord span is approximately 6'-9''. The existing roof framing system of (MP1) is judged to be adequate to withstand the loading imposed by the installation of the solar panels. No reinforcement is necessary. Ground Snow Load = 50 psf - Roof Snow Load = 35 psf The spacing of the solar standoffs should be kept at 48" o.c. for landscape and 24" o.c. for portrait orientation, with a staggered pattern to ensure proper distribution of loads. A jobsite observation of the condition of the existing framing system was performed by an audit team of Blue Raven Solar as a request from Domus Structural Engineering. All review is based on these observations and the design criteria listed below and only deemed valid if provided information is true and accurate. On the above referenced project, the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof. The structural review only applies to the section of the roof that is directly supporting the solar PV system and its supporting elements. The observed roof framing is described below. If field conditions differ, contractor to notify engineer prior to starting construction. The scope of this report is strictly limited to an evaluation of the fastener attachment, underlying framing and supporting structure only. The attachment's to the existing structure are required to be in a staggered pattern to ensure proper distribution of loading. All panels, racking and hardware shall be installed per manufacturer specifications and within specified design limitations. All waterproofing shall be provided by the manufacturer. Domus Structural Engineering assumes no responsibility for misuse or improper installation of the solar PV panels or racking. Please contact me with any further questions or concerns regarding this project. Note: Seismic check is not required since Ss<.4g and Seismic Design Category (SDC) < B Attachment: 1 - 5/16 dia. lag screw with 2.5 inch min. embedment depth, at spacing shown above. I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota.John A. Calvert, License No. 52823 Expiration Date: 30-June-2024 Kabrawala Lakeville MN 1 Digitally signed by John A. Calvert Date: 2023.10.27 13:03:30 -06'00' ___________________________________________________________________________________________ Domus Structural Engineering, LLC P.O. Box 560 Broomfield, CO 80038 530-864-7055 projects@domusstruc.com 50.0 psf (ASCE7 - Eq 7-1) 1 (ASCE7 - Table 7-2) 1 (ASCE7 - Table 7-3) 1 35.0 psf (ASCE7 - Eq 7-2) 1 35.0 psf 3.37 psf 3.0 psf 2.00 ft 6.08 ft 12.17 sft 37 lb 4.00 2.00 0.73 0.00 (Ceiling Not Vaulted) 0.27 7.0 psf 7.9 psf Gravity Loading PV System Weight Weight of PV System (Per Blue Raven Solar) X Standoff Spacing = Y Standoff Spacing = Note: PV standoffs are staggered to ensure proper distribution of loading 2x4 Top Chords @ 24"o.c. I = Importance Factor = Cs = Slope Factor = Standoff Tributary Area = ps = Cspf ps = Sloped Roof Snow Load = pf = Flat Roof Snow Load = DL Adjusted to 27 Degree Slope Roof Snow Load Calculations pg = Ground Snow Load = Ce = Exposure Factor = pf = 0.7 Ce Ct I pg Ct = Thermal Factor = Roof Live Load = 20 psf Roof Plywood Roof Dead Load (MP1) Composition Shingle Note: Roof live load is removed in area's covered by PV array. DL Adjusted to 27 Degree Slope Point Loads of Standoffs Miscellaneous Vaulted Ceiling Total Roof DL (MP1) PV Dead Load = 3 psf (Per Blue Raven Solar) Kabrawala Lakeville MN 2 ___________________________________________________________________________________________ Domus Structural Engineering, LLC P.O. Box 560 Broomfield, CO 80038 530-864-7055 projects@domusstruc.com 115 mph C Gable Roof 27 degrees 20 ft 21.3 ft 0 ft (Eq. 26.10-1) 0.90 (Table 30.3-1) 1.00 (Fig. 26.8-1) 0.85 (Table 26.6-1) 1.00 115 mph (Fig. 26.5-1A) II (Table 1.5-1) qh = 25.95 Zone 1 Zone 2 Zone 3 Positive ya =0.77 0.80 0.80 0.77 GCp =-1.50 -2.50 -3.59 0.52 (Fig. 30.3) Uplift Pressure =-30.0 psf -51.9 psf -74.5 psf 10.3 psf (Eq. 29.4-7) ASD Uplift Pressure =-18.0 psf -31.1 psf -44.7 psf 9.6 psf X Standoff Spacing = 2.00 2.00 1.33 Y Standoff Spacing = 6.08 3.04166667 3.04166667 Tributary Area = 12.17 6.08 4.06 Dead Load on attachment = 37 lb 18 lb 12 lb Footing Uplift (0.6D+0.6W) = -197 lb -179 lb -174 lb Zone 1 Zone 2 Zone 3 Positive ya =0.75 0.80 0.80 0.75 GCp =-1.50 -2.50 -3.49 0.50 (Fig. 30.3) Uplift Pressure =-29.2 psf -51.9 psf -72.5 psf 9.8 psf (Eq. 29.4-7) ASD Uplift Pressure (0.6W)=-17.5 psf -31.1 psf -43.5 psf 9.6 psf X Standoff Spacing = 4.00 4.00 2.67 Y Standoff Spacing = 3.50 1.75 1.75 Tributary Area = 14.00 7.00 4.67 Dead Load on attachment = 42.00 21.00 14.00 Footing Uplift (0.6D+0.6W) = -220 lb -205 lb -195 lb -220 lb 450 lb Therefore, OK Fastener =1 - 5/16" dia. lag Number of Fasteners = 1 Embedment Depth = 2.5 Pullout Capacity Per Inch = 250 lb Fastener Capacity = 625 lb w/ F.S. of 1.5 & DOL of 1.6= 667 lb Therefore, OK Fastener Capacity Check Mean Roof Height Ground Elevation Kd (Wind Directionality Factor) = 667.2 lb capacity > 220 lb demand Ke (Ground Elevation Factor) = V (Design Wind Speed) = Risk Category = Standoff Uplift Calculations-Portrait Standoff Uplift Calculations-Landscape Standoff Uplift Check Standoff Uplift Capacity = 450 lb capacity > 220 lb demand Wind Calculations Maximum Design Uplift = Design Wind Pressure Calculations qh = 0.00256 * Kz * Kzt * Kd * Ke * V^2 Kz (Exposure Coefficient) = Kzt (topographic factor) = Wind Speed Exposure Category Roof Shape Roof Slope Effective Wind Area Per ASCE 7-16 Components and Cladding Input Variables Kabrawala Lakeville MN 3 ___________________________________________________________________________________________ Domus Structural Engineering, LLC P.O. Box 560 Broomfield, CO 80038 530-864-7055 projects@domusstruc.com (MP1)PASS Dead Load 7.9 psf PV Load 3.4 psf Snow Load 35.0 psf Governing Load Combo = DL + SL Total Load 46.2 psf Fb (psi) = f'b x Cd x Cf x Cr (NDS Table 4.3.1) 1650 x 1.15 x 1 x 1.15 Allowed Bending Stress = 2182.1 psi (wL^2) / 8 = 526.5118 ft# = 6318.142 in# Actual Bending Stress = (Maximum Moment) / S = 2063.1 psi L/180 (E = 1500000 psi Per NDS) = 0.45 in Deflection Criteria Based on = (w*L^4) / (185*E*I) = = L/364 > L/180 Therefore OK Allowed Deflection (Live Load) =L/240 0.337 in (w*L^4) / (185*E*I) L/480 > L/240 Therefore OK Member Area = Fv (psi) = 135 psi (NDS Table 4A) Allowed Shear = Fv * A = Max Shear (V) = w * L / 2 = 312 lb Framing Check 5.3 in^2 Check Shear w = 92 plf 2x4 Top Chords @ 24"o.c. Member Span = 6' - 9" 709 lb Allowed > Actual -- 44.1% Stressed -- Therefore, OK 1650Fb/1.5E Member Spacing @ 24"o.c. Maximum Moment = Check Deflection I (in^4) 5.36 Lumber Sp/Gr Actual Deflection (Live Load) = Allowed Deflection (Total Load) = Actual Deflection (Total Load) = Allowed > Actual -- 94.6% Stressed -- Therefore, OK Member Properties Member Size 2x4 S (in^3) 3.06 0.169 in Continuous Span 0.223 in Check Bending Stress (True Dimensions) Kabrawala Lakeville MN 4 ___________________________________________________________________________________________ Domus Structural Engineering, LLC P.O. Box 560 Broomfield, CO 80038 530-864-7055 projects@domusstruc.com Appendix A: General Notes GENERAL Ɣ The contractor shall verify all dimensions, property setbacks, AHJ/HOA CC&R's, elevations and site conditions before starting work and shall notify Domus Structural Engineering, LLC of any discrepancies. Ɣ All report conclusions represent Domus Structural Engineering, LLC's best professional judgment based upon industry standards. Ɣ Resolve any conflicts on the drawings with Domus Structural Engineering, LLC before proceeding with construction. Ɣ The design criteria used for this project & listed on the first page of the report is based on the engineers best judgement and/or provided by the ATC council. AHJ specific requests may differ. Please contact our team if the design criteria needs to be modified. Ɣ A site visit was not physically conducted by Domus Structural Engineering, LLC. The accompanying calculations and certification are provided with the understanding that the site building and construction standards meet an acceptable level of industry standards. It shall be the contractors responsibility to identify any irregularities such as inconsistent framing conditions, water damage, fire damage, cracked, split or noticeably deflecting framing members. Ɣ Domus Structural Engineering, LLC is not responsible for enforcing safety measures or regulations. The contractor shall design, construct, and maintain all safety devices including shoring and bracing, and shall be solely responsible for conforming to all local, state and federal safety and health standards, laws and regulations. The contractor shall take necessary precautions to maintain and insure the integrity of the structure during construction. If a lawsuit is filed by one of the contractor's or subcontractor's employees, or any one else, the contractor will indemnify, defend and hold the owner and Domus Structural Engineering, LLC harmless of any and all such claims. Ɣ Any and all waterproofing shall be provided by the contractor. Domus Structural Engineering, LLC is not responsible for waterproofing. Ɣ All hardware shall be installed per manufacturer specifications and within specified design limitations. Domus Structural Engineering, LLC assumes no responsibility for incorrectly installed hardware or hardware installed outside of the manfacturer specifications. USER RELIANCE Ɣ Domus Structural Engineering, LLC was engaged by Blue Raven Solar (Client) to perform this assessment. This report and the information therein, are for the exclusive use of the Client. This report has no other purpose and shall not be relied upon, or used, by any other person or entity without the written consent of Dous Structural Engineering, LLC. Third parties that obtain this report, or the information within shall have no rights of recourse or recovery against Domus Structural Engineering, LLC, it’s officers or employees. ROOF MOUNTED ARRAYS Ɣ If an analysis of a supporting stucture is included in our scope of work, the structural assessment only applies to the section of the roof that is directly supporting the proposed solar PV system. Ɣ No structural members can be cut for conduit, etc., unless specifically shown. Obtain prior written approval for installation of any additional conduit, etc. Ɣ It is assumed that a standard quality of construction care was used to construct the original building. It shall be the contractors responsibility to field verify any and all framing member supporting the proposed PV array are in adequate condition. The contractor shall field inspect for sub-standard construction means, signs of dry rot, mold, fire damage, etc. and notify engineer if any compromised material is found on site prior to starting construction. Ɣ It is assumed that there have been no additional loads (HVAC or MEP equipment, additional layers of roofing, etc) added to the building over the course of the structures histroy. The contractor and/or client shall verify this with the property owner and notify Domus Structural Engineering, LLC if additional load has been added to the structure already. Ɣ Flexible utility connections must be used at any building seismic joint. Ɣ Care should be taken to ensure that PV arrays do not preclude drainage of rain water. Ɣ Unless otherwise noted, construction material shall be evenly distributed if placed on framed floors or roofs. Loads shall not exceed the allowable loading for the supporting members and their connections. Ɣ All lags or wood screws at the roof shall be stainless steel and installed withing the middle 1/3 of the dimensional width of the framing members. Ɣ All fasteners shall be a minimum of 6" away from any truss panel or hinge joints, truss plates and/or member ends. Field verify location of fasteners prior to starting construction. All fasteners shall be pre-drilled to avoid splitting existing lumber. Ɣ Domus Structural Engineering, LLC is not responsible for downslope effects of snow shedding or sliding off of the PV array nor any damage to downslope decks, roofs, walkways, landscaping, automobiles, pets, people, etc.. If snow guards are requested by the customer, notify Domus Structural Engineering, LLC. Kabrawala Lakeville MN 5