Loading...
HomeMy WebLinkAboutLA220112THE FOLLOWING INFORMATION MUST BE INCLUDED WITH YOUR APPLICATION: Payment for amount of permit. For freestanding/monument/pylon sign - a site plan with setback from property line dimensions and art work with dimensions of sign, and engineered design for footings and foundation. For wall sign, art work with dimensions of sign and drawings of building façade showing location of sign. If illuminated or if electrical services are needed, a separate electrical permit is required. If leased space, need to include a letter of approval from the property owner. SIGN LOCATION Name__________________________________________________________________________________ Address________________________________________________________________________________ City ____________________________________State__________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ PROPERTY OWNER Name__________________________________________________________________________________ Address________________________________________________________________________________ City ____________________________________State__________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ SIGN CONTRACTOR Company Name _________________________________________________________________________ Address________________________________________________________________________________ City ___________________________________ State___________________ Zip _____________________ Contact _____________________________________Day Phone # ________________________________ Email Address __________________________________________________________________________ SIGN DESCRIPTION Electronic ($100 per sign plus completion of electronic sign license, see Page 2) Permanent ($75 per sign) Temporary ($50 per event, up to 60 days per year. Max of one temp sign displayed at a time.) Temporary sign displayed dates: START DATE ________________________ END DATE ________________________ Sign Type and Dimensions Wall Sign: Width ____________ Height: _______________ Square feet _____________________________ Freestanding: Face Width_________ Height____________ Sq. ft__________ Overall Sign Height _________ Setbacks: Front _________ Side ____________ Temporary Width___________ Height ______________ Sign Square Feet______________________ Display location _______________________ Illuminated Sign: Internally illuminated Externally illuminated Not illuminated Type of Work: New Sign Replacement Sign Alter Existing Sign Changeable Copy: No Changeable Copy Manual Changeable Copy Electronic Changeable Copy (Electronic sign will require annual license review & renewal, see Page 2) Applicant Signature: ____________________________________________Date:_________________ Applicant Printed Name: _______________________________________________________________ SIGN PERMIT APPLICATION & ELECTRONIC SIGN LICENSE City of Lakeville – Planning Department 20195 Holyoke Avenue - Lakeville, MN 55044 952.985.4420 - www.lakevillemn.gov Anytime Fitness 17811 Kenwood Trail 54044MNLakeville Nathan Jesperson nathanj@community-ventures.net 651.308.5556 Archetype Signmakers 9611 James Ave. S. Bloomington MN 55431 Erin Wahl 952-641-9644 erinw@archetypesign.com Erin Wahl x x x  x 19'-3/4"5' 95.31 Grand Real Estate Advisors, LLC 90 Dale St. South St. Paul MN 55102 Ted LaFave 612-875-3858 tlafave@grandrea.com 11/10/23 LA220112 X SIGN PERMIT APPLICATION & ELECTRONIC SIGN LICENSE Page 2 Electronic Display/Changeable Copy Sign License Single occupancy building with gross floor area over 70,000 sq. ft. within the C-3 District and within the Freeway Corridor District. By signing below you are certifying the electronic signage meets the following performance standards: 1.The display sign shall not change more than once every twenty four (24) hours. 2.The display sign shall not include scrolling, flashing, animation, or other effects. 3.The display must be static and the transition from one static display to another must be instantaneous without special effects. 4.The display image or message must be self-contained, without continuation in content to the next image or message. 5.The brightness of the sign shall not exceed 5,000 NITS after sunrise and before sunset or 500 NITS after sunset and before sunrise each day. 6.The sign shall be equipped with an automatic dimmer control or other mechanism that automatically controls the sign’s brightness to comply with this condition. 7.The display must be designed and equipped to freeze the device in one position if a malfunction of the electronic display occurs. 8.The display must also be equipped with a means to immediately discontinue the display if it malfunctions, and the sign owner must immediately stop the electronic display when notified by the City that it is not complying with the stipulations of this section. 9. The sign shall comply with Chapter 23 of the Zoning Ordinance. Signature_______________________________________ Date______________________________ Print Name______________________________________ Email ________________________________ EXPIRATION AND RENEWAL OF LICENSE: •All licenses expire on December 31st of each year. •License may be renewed only by making application as provided in Section 3-22-4 of the City Code. •Application for renewal shall be made at least sixty (60) days before the expiration date. •Each renewal license shall be issued for a maximum period of one (1) year. •Annual license renewal fee is $50.00 Office Use Only Sign Permit Type: Permanent Sign _____ Temporary Sign _____ Electronic Sign _____ Work Type: New _____ Addition _____ Repair _____ Demolish_____ Replace _____ Alter/Remodel _____ Move _____ Owner: Public _____ Private _____ Zoning District: Commercial _____ Industrial _____ Residential_____ Freeway Corridor _____ Required Inspections: Footing _____ Final _____ Permit Fee: Permit Fee _____________ Miscellaneous ___________ Total ___________________ Comments: ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ ________________________ Approved by:____________________________ Date:___________________________________ (REVISED APRIL 2022) X X X X $75.00 $75.00 C-3 16 November 2023 *Email kjenson@lakevillemn.gov after installation for final inspection. 1.1 Channel Letters - Moniker Raceways Front Elevation Scale: 1/8” = 1’-0’’1 LEASE SPACE SIGNBAND MOUNT TO WALL USING LAGS AND LAG SHIELDS Install LettersB Illumination LogoA FACES: 3/16’’ ACRYLITE WHITE ACRYLIC (7328) DIGITALLY PRINTED WHITE VINYL OVERLAY - COLOR TO MATCH PMS 2097C (C/W/C)(NYALA) RETURNS: ALUMET 3’’ BLACK ALUMINUM CHANNEL COIL TRIMCAPS: JEWELITE 1’’ BLACK FACES: 3/16’’ ACRYLITE WHITE ACRYLIC (7328) RETURNS: ALUMET 3’’ BLACK ALUMINUM CHANNEL COIL TRIMCAPS: JEWELITE 1’’ BLACK PHOTOCELL CONTROLLER Description CabinetC RacewaysD SIGNCOMP: 2 PIECE 8" CHANNEL LETTER RACEWAY (FRONT 1981/BACK 1982) (OR FABRICATED EQUIVALENT) PAINTED TO MATCH SW6070 HERON PLUME 6’’ X 1’’ ALUMINUM CHANNEL FRAME - ALUMINUM ANGLE RETAINERS - 1/8’’ ROUTED ALUMINUM FACE - PAINTED BLACK (SATIN FINISH) - 3/4’’ CLEAR ACRYLIC PUSH-THRU COPY (1/2’’ PROJECTION) - SECOND SURFACE TRANSLUCENT WHITE VINYL DIFFUSER (230-20) Channel Letters | SF Cabinet w/ Push-Thru Copy| Raceway Scale: 1/2” = 1’-0”2 3’’ D 4 3/8’’ 6" PROFILE RACEWAY 1 - 119” RACEWAY 3 109” RACEWAY 2 - 96” RACEWAY 4 - 83” 60” 55 3/4”142 3/4” 20” 20” 167” 228 3/4” 10 3/4”5 3/8” CRITERIA: CITY CRITERIA: LANDLORD ZONE: C3 - NOT TO EXCEED 100 SQFT SUBMIT FOR APPROVAL ALLOWED: 100.00 SQFT PROPOSED: 95.31 SQFT CONCEPT DRAWING THIS DRAWING IS FOR PRESENTATION PURPOSES ONLY CONTINGENT ON FIELD SURVEY, CITY AND LANDLORD APPROVAL. ALL DIMENSIONS MUST BE FIELD VERIFIED PRIOR TO FABRICATION PRISM SYNERGY MINI 6500K WHITE LED UNITS 199 L.E.D. MODULES - 111 LINEAL FEET TOTAL (1) HE 96W 24V POWER SUPPLY (P-OH096-24-HE) 110-277 VAC - 60 Hz 0.98 @ 100VAC, 0.42@ 277 VAC 88” 28-2” 81’-4” CURRENT CONDITION 9611 James Ave S. Minneapolis, Minnesota 55431 952 641 9600 archetypesign.com This print is meant as a representation of a sign show vin consideration of being manufactured by Archetype. Materials may influence final result. Samples available upon request. Graphic Design time is included in the total purchase price. Designs contained herein are not meant to be exhibited to others outside of included parties and employees. Designs received from Archetype may not be manufactured by others without reimbursement for time spent in the creation of these designs or any resemblance. Drawings may contain elements considered artistic intellectual property of Steve Carpenter, owner. ©Archetype Page: Type: Approved: Contact: Description: Project: Job Number: Date: Rev. 1: Rev. 2: Rev. 3: Rev. 4: Rev. 5: Designer: Jenny Kruse 952 641 9602 jennyk@archetypesign.com Anytime Fitness Lakeville, MN Q-105864 09.29.23 DG LA220112 1.2 Channel Letters - Moniker on Raceways - Detail SECONDARY JUNCTION BOX 6” LED UNITS WELD 1-1/2” X 1-1/2” X 1/8” ALUM. MOUNTING ANGLE .080” ALUM. RETURNS 1/8” ALUMINUM FACE .040” PRE-FIN WHITE ALUM. BACK 1/2” CLEAR ACRYLIC PUSH THRU W/ 2ND SURFACE DIFFUSER THROUGH WALL - PENETRATION SEALED W/ SILICONE 6' MIN. CONDUIT W/ 3- 12 GA. WIRES (WHITE , BLACK & GREEN) CLASS 2 LOW VOLTAGE WIRES TO LED DRIVER LED DRIVER IN TRANSFORMER BOX FINAL ELECTRICAL CONNECTION BY OTHERS Section Scale: 3”=1’-0”1 PUSH THRU CABINET SECTION (COMBINED WITH RACEWAY MOUNTED CHANNEL LETTERS) TRIM CAP .040 PRE-FINISHED ALUMINUM RETURN .050" PRE-FINISHED WHITE ALUMINUM BACK 3/16" ACRYLIC FACE LED UNITS CLASS 2 LOW VOLTAGE WIRES TO LED DRIVER LED DRIVER NON-CORROSIVE WALL ANCHOR SIZE & STYLE DETERMINED BY MOUNTING APPLICATION RACEWAY COVER RACEWAY FRONT RACEWAY BACK RACEWAY BRACE / BRACKET DRAIN HOLES (1) 1/4" HOLE PER 4' RACEWAY THROUGH WALL - PENETRATION SEALED W/ SILICONE FINAL ELECTRICAL CONNECTION BY OTHERS SLAT WALL (DETAILS TBD) SLAT WALL (DETAILS TBD) 6' MIN. CONDUIT W/ 3- 12 GA. WIRES (WHITE , BLACK & GREEN) 3’’4 3/8’’ Section Scale: NTS3 CHANNEL LETTER (3’’ DEPTH) ON RACEWAY RIGID CONDUIT FROM BOTTOM OF LOWER RACEWAY RIGID CONDUIT TO FEED SUB COPY CABINET 9611 James Ave S. Minneapolis, Minnesota 55431 952 641 9600 archetypesign.com This print is meant as a representation of a sign show vin consideration of being manufactured by Archetype. Materials may influence final result. Samples available upon request. Graphic Design time is included in the total purchase price. Designs contained herein are not meant to be exhibited to others outside of included parties and employees. Designs received from Archetype may not be manufactured by others without reimbursement for time spent in the creation of these designs or any resemblance. Drawings may contain elements considered artistic intellectual property of Steve Carpenter, owner. ©Archetype Page: Type: Approved: Contact: Description: Project: Job Number: Date: Rev. 1: Rev. 2: Rev. 3: Rev. 4: Rev. 5: Designer: Jenny Kruse 952 641 9602 jennyk@archetypesign.com Anytime Fitness Lakeville, MN Q-105864 09.29.23 DG