Loading...
HomeMy WebLinkAboutLA220210-5818 178th St Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND MAIN FLOOR1' -8 1/4"UPPER PLATE20' -11 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -10 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"ALUMINUM SOFFIT& FASCIA TYP.6" SMARTSIDEFRIEZE BOARD TYP.VINYL BOARD &BATTEN TYP.VINYL LAP SIDING & VINYL CORNERS ALL SIDESCULTURED STONE W/CONCRETE CAP4" SMARTSIDE TRIM@ WINDOWS & DOORSTYP. -FRONT ONLYADDRESS STONE6" SMARTSIDE STORYBOARD TYP.4' - 6"22020 NVFA1R.O. 2' -0" x 2' -0"H.H. 2' -6"SEE COLUMN DETAIL SHEET A-5017" / 12"4" / 12"8" 12"GARAGE PLATE HEIGHT10' - 9 3/8"8" 12"GREAT ROOM PLATE11' -9 3/8"10' - 1 1/8"1/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 5TOTAL:RELEASED 11/9/2023 1:08:56 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-201OTT361123912548778'-1 1/8"9'-1 1/8"8'-4" POUR10.26.23 CB11 9.23 CB9.29.23 CB34704.19.23 CBTHE PAYTON XLSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONA-202 ELEVATIONSA-401 FOUNDATION PLANA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 ROOF/ WINDOW SCHEDULEA-502 DETAILSA-503 SECTIONConcept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode11/15/2023jnuetzman 24" RETURNSTYPICAL7" 12"7" / 12"8" / 12"8" / 12"8" / 12"7" / 12"MAIN FLOOR1' -8 1/4"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING& CORNERS @SIDES & REAR7" / 12"7" 12"GREAT ROOM PLATE11' -9 3/8"8" 12"10' - 1 1/8"7" 12"24" RETURNSTYPICAL7" 12"4" 12"8" / 12"8" / 12"7" / 12"STANDARD ENERGY HEELS @ 7:12W/ 8:12 TO MATCH FASCIA LINE18" OVERHANGS & 12" RAKES TYP.7 ROOF VENTS @ HOUSE4 ROOF VENTS @ GARAGE7" / 12"8" / 12"8" / 12"8" / 12"8" / 12"7" / 12"7" / 12"4" / 12"STANDARD ENERGY HEELS @ 4:12 W/ 8:12 TO MATCH FASCIA LINES7" / 12"7" / 12"1 ROOF VENTS7" / 12"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 5TOTAL:RELEASED 11/9/2023 1:08:59 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-202OTT361123912548778'-1 1/8"9'-1 1/8"8'-4" POUR10.26.23 CB11 9.23 CB9.29.23 CB34704.19.23 CBTHE PAYTON XL1/8" = 1'-0"A-2021RIGHT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023LEFT ELEVATION1/8" = 1'-0"A-2024ROOF PLANSecure door closed until deck isconstructed with a separate permit. 54' - 0"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"50' - 0"34' - 2"19' - 10"14' - 0"5' - 10"28' - 2"6' - 0"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE19' - 8"24' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE54' - 0"15' - 8 1/4"3' - 4 1/2"4' - 5 1/4"4' - 5 1/4"16' - 0 3/4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.31' - 6"22' - 6"44' - 0"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"26' - 4"15' - 6"12' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2' - 0"20' - 6"25' - 6"6' - 0"1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.44' - 0"6' - 0"3' - 11"7' - 7 1/4"0' - 10"19' - 11 3/4"LEAVE A 12" GAP IN FOOTINGFOR PLUMBING:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE50' - 0"2' - 3 1/4"8' - 5 1/2"5' - 3 1/4"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY0' - 4"7' - 0 3/4"12' - 7 1/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY17' - 0"11' - 0"16' - 0"14' - 8"11' - 8"36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAYTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 5TOTAL:RELEASED 11/9/2023 1:09:00 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-401OTT361123912548778'-1 1/8"9'-1 1/8"8'-4" POUR10.26.23 CB11 9.23 CB9.29.23 CB34704.19.23 CBTHE PAYTON XL1/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. UNEXCAVATEDSUMPW. H.F. D.4' VANITYFAMILY ROOMBEDROOM #5BATH31' - 6"22' - 6"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"34' - 2"19' - 10"15' - 10"5' - 10"4' - 8"CO DET.18" FLOOR TRUSSESPER MFG. SPACING19' - 3 1/2"4' - 2 1/2"4' - 2 1/2"16' - 3 1/2"12/4 x 6/8R.O. 2' -6" x 6' -11"48" F.G. SHWR32/6 x 6/8R.O. 2' -8" x 6' -11"18" FLOOR TRUSSESPER MFG. SPACING14' - 0"5' - 10"28' - 2"6' - 0"12' - 8"15' - 6"UNEXCAVATED6' - 0"44' - 0" (BRACED WALL LINE SPACING)2x610' - 7"0' - 5"3' - 8"SMOKEDET.*3-1/2" CONC. FLOOR*MECHANICALS MAY VARY19' - 8"24' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/SHEATHING2-2x10 W/2 TRIMMERS2-2x102-2x102-2x10 W/2 TRIMMERS 50' - 0"44' - 0"4' - 3 1/4"7' - 4 3/4"3' - 11"10' - 9"0' - 4"14' - 8"11' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.4' - 2 1/2"15' - 1"3' - 6"52/8 x 6/8R.O. 2' -10" x 6' -11"MECHANICAL12/4 x 6/8R.O. 2' -6" x 6' -11"AIR EX.2" FOAM INSULATIONBETWEEN WALL & SLAB1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"2' - 0"20' - 6"25' - 6"6' - 0"26' - 4"54' - 0"54' - 0"7' - 10"9' - 2"5' - 6"5' - 6"6' - 6"9' - 6"75040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"108040E NVGER.O. 8' -0" x 4' -0"H.H. 6' -10"32/6 x 6/8R.O. 2' -8" x 6' -11"50' - 0"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.3-2x10 W/2 TRIMMERS 2-11 7/8" LSL FLUSH3-9 1/2" LSL W/3 TRIMMERSCS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.15'-6" OF WALL BRACINGREQUIRED. BRACE TO FOUNDATIONOR UNTIL MINIMUM IS MET31' - 0" (BRACED WALL LINE SPACING)15'-6" OF WALL BRACINGREQUIRED. BRACE TO FOUNDATIONOR UNTIL MINIMUM IS MET0' - 4"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"17' - 0"11' - 0"16' - 0"CS-WSP2' - 6" B.W.P.SMOKEDET.2-2x10R & SH. @ 65CLOSETFURNACE4-2x62-2x101/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 5TOTAL:RELEASED 11/9/2023 1:09:01 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-402OTT361123912548778'-1 1/8"9'-1 1/8"8'-4" POUR10.26.23 CB11 9.23 CB9.29.23 CB34704.19.23 CBTHE PAYTON XL-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). 22' - 6"31' - 6"34' - 0"20' - 0"50' - 0"KITCHENDINING ROOMFOYEROFFICE12" BOX VAULTDWGARAGEPORCH6' - 0"28' - 0"6' - 0"14' - 0"18' - 10"31' - 2"20' - 2"11' - 0"9' - 6"6' - 6"5' - 6"5' - 6"2' - 0"8' - 3"6' - 9"50' - 0"2' - 1"16' - 0"2' - 1"1' - 3"8' - 0"1' - 9"0' - 10"5' - 2"1' - 0"11' - 0"7' - 4"SMOKEDET.2-11 7/8" LSL4' - 2"4' - 0"12" CANT. ABOVE3' - 10"9' - 0"6' - 6"SEE COLUMN DETAIL SHEET A-5014' - 4"5' - 10"0' - 10"15' - 0"MFG. ROOF TRUSSES@ 24" O.C.2-9 1/2" LSL W/3 TRIMMERS2-2x10 DROPPED TYP.0' - 4 1/2"6' - 0"25' - 6"20' - 6"2' - 0"2-2x126' - 0"44' - 0"SNACK BAR19' - 4"4' - 0"1' - 4"CS-WSP3' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.SINK3/0 x 6/8 OPG.82-2x102-11 7/8"LSL FLUSH W/3 TRIMMERS2-2x10 W/2 TRIMMERS2-2x10CS-WSP3' - 6" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.2-2x1054' - 0"3' - 2 3/4"5' - 6"3' - 2"12' - 2"19' - 5"5' - 0"7' - 5"12' - 6"15' - 6"19' - 3 1/2"4' - 2 1/2"4' - 2 1/2"16' - 3 1/2"2-2x1024" CANT. ABOVE26' - 0"14' - 8"10' - 0"KNEE WALL W/14" SPINDLES2-2x102-11 7/8"LSL FLUSH W/3 TRIMMERS2-11 7/8"LSL FLUSHW/ 2 TRIMMERS5/0 x OPG. TO CEILING109" HEAT DUCT2' - 0"2' - 0"14' - 10 7/8"2' - 8 1/2"10' - 4 5/8"EQEQ63650 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 6' -11 1/2"H.H. 8' -0"6653636 NVG1R.O. 3' -6" x 3' -6"H.H. 7' -2"43016 NVPWGR.O. 3' -0" x 1' -6"H.H. 8' -0"96050E NVG1R.O. 6' -0" x 5' -0"H.H. 6' -10"ATTICACCESSCS-WSP4' - 0" B.W.P.16" SH.16" SH.PAINTED CABINETSFULL TILE BACKSPLASH16' x 8' O.H. GARAGEDOOR138' x 8' O.H. GARAGEDOOR1254' - 0"CS-WSP5' - 0" B.W.P.PANTRY4' - 4"2' - 8"4' - 4"GAS LINE FOR RANGE1' - 0"55" LINEAR ELEC. F.P.2' - 0"11' - 4"14' - 8"24" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.FRAME BOTTOM OFWINDOW @ 44" A.F.F.HGUS4124" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. CEILING1/2" GYP. BD. ON GARAGE WALLS GARAGE PLATE HEIGHT TO MATCHMAIN FLOOR UNLESS NOTED OTHERWISEPFH1' - 9"PFH2' - 1"PFH2' - 1"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES17' - 0"11' - 0"16' - 0"A-50312x62' - 8"2' - 11"5' - 9"12/4 x 6/8R.O. 2' -6" x 6' -11"MUD ROOM30" GAS COOKTOPW/ WOOD HOODABOVE OVEN/MICROPWDR.36" REFTYP.2' - 0"6' - 0"GREAT ROOM10' PLATESET FIREPLACE @ F.F.HALF HIGH STONE WRAPPED TO EXTERIOR WALL W/ WRAPPED MANTELCS-WSP2' - 8" B.W.P.2-11 7/8" LSL FLUSH10'-1 1/8" PLATE HAND FRAME CEILING DOWN FOR ANGLE CEILING ABOVE 24" FLOOR TRUSSESPER MFG. SPACING9' CEILING CEILING STEPS TO 10'CEILING STEPS TO 10'9' CEILING 62/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"MFG. ROOF TRUSSES@ 24" O.C.22/4 x 6/8 PKTR.O. 4' -10" x 6' -11"PED. SINK12" FLOOR TRUSSESPER MFG. SPACING72/8 x 6/8 FULL VIEWR.O. 2' -10 1/2" x 6' -10 1/4"6624" CANT. ABOVE 24' - 8"CS-PF1' - 9" B.W.P.CS-PF1' - 9" B.W.P.43016 NVPWGR.O. 3' -0" x 1' -6"H.H. 8' -0"2-2x10HHUS482-2x104-2x63-2x63-2x62-2x102-9 1/2" LSL CONT. 2-2x103-2x69' - 4"1' - 8"11' - 4"14' - 8"93/0 x 6/8 W/ 2-12" D.S. S.L.'S & 12"TRANSOM4-2x61/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 5TOTAL:RELEASED 11/9/2023 1:09:02 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-403OTT361123912548778'-1 1/8"9'-1 1/8"8'-4" POUR10.26.23 CB11 9.23 CB9.29.23 CB34704.19.23 CBTHE PAYTON XLFANBWPsAboveBWPsAbove-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). LAUNDRYOWNER'S SUITEHALL1/2 WALL W/WOOD CAPSMOKEDET.SMOKEDET.6' VANITYCLOSETSMOKEDET.BEDROOM #2GIRDER TRUSSCO DET.SMOKEDET.ATTICACCESS2' LINEN13' - 0"31' - 0"3' - 0"28' - 0"29' - 0"2' - 0"16' - 0"28' - 0"5' - 7"14' - 11"7' - 6"6' - 6"6' - 6"2' - 6"8' - 0"20' - 6"VAULT LINE2-2x10 W/2 TRIMMERS2-2x102-2x102-2x10CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.44' - 0"5' - 9"22' - 3"44' - 0"13' - 5"7' - 10 1/2"3' - 4 1/2"4' - 4"7' - 0"4' - 2 1/2"5' - 5 1/2"5' - 6"5' - 10"4' - 0 3/4"2' - 8"2' - 10"4' - 3"2' - 6 1/2"12' - 1"2' - 6"3' - 8"9' - 4 3/4"19' - 3 1/2"4' - 2 1/2"4' - 2 1/2"16' - 3 1/2"4' - 4"5' - 0"1' - 8"17' - 0"2-2x1032020 NVFA2R.O. 4' -0" x 2' -0"H.H. 6' -10"85050E NVG1R.O. 5' -0" x 5' -0"H.H. 6' -10"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"85050E NVG1R.O. 5' -0" x 5' -0"H.H. 6' -10"75040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"KNEE WALL W/14" SPINDLESMFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACINGEN SUITE3-2x6A-503131' - 0"31' - 0"13' - 7 1/4"2' - 6"32/6 x 6/8R.O. 2' -8" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"5' TUB/SHWR3' VANITYSMOKEDET.GIRDER TRUSS52/8 x 6/8R.O. 2' -10" x 6' -11"4:12 3-2x632/6 x 6/8R.O. 2' -8" x 6' -11"10' - 8"1' - 8"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"6' - 0 1/2"22' - 11 1/2"MFG. ROOF TRUSSESPER MFG. SPACING42/6 x 6/8 PKTR.O. 5' -2" x 6' -11"GIRDER TRUSSROUGH IN SINKBEDROOM #3BEDROOM #4R & SH. @ 65BATH2x6R & SH. @ 66 WIRER & SH. @ 65WASHERDRYER32/6 x 6/8R.O. 2' -8" x 6' -11"4' - 3 1/2"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES712/4 x 6/8R.O. 2' -6" x 6' -11"12' - 5"32/6 x 6/8R.O. 2' -8" x 6' -11"3' x 5' TUB W/ 4" TILEDECK3' - 5"0' - 4"2' - 4"CURBTILE SHOWER 42" WALL W/ GLASS PANEL DBL: FRAME2-2x102-2x104-2x64-2x6CS-WSP2' - 8" B.W.P.THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 5TOTAL:RELEASED 11/9/2023 1:09:03 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-404OTT361123912548778'-1 1/8"9'-1 1/8"8'-4" POUR10.26.23 CB11 9.23 CB9.29.23 CB34704.19.23 CBTHE PAYTON XL1/4" = 1'-0"A-4041UPPER FLOOR PLANFANFAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).Verify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing. WATCH DOG WATER PROOF COATINGFROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 5TOTAL:RELEASED 11/9/2023 1:09:04 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-501OTT361123912548778'-1 1/8"9'-1 1/8"8'-4" POUR10.26.23 CB11 9.23 CB9.29.23 CB34704.19.23 CBTHE PAYTON XL3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:3/8" = 1'-0"A-5012TYP. WALL SECTIONWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 VECTOR ENVISION SERIES 2 2020 NVA1 2' - 0" 2' - 0" 6' - 10"2 VECTOR ENVISION SERIES 1 2020 NVFA1 2' - 0" 2' - 0" 2' - 6"3 VECTOR ENVISION SERIES 1 2020 NVFA2 4' - 0" 2' - 0" 6' - 10"4 VECTOR ENVISION SERIES 2 3016 NVPWG 3' - 0" 1' - 6" 8' - 0"5 VECTOR ENVISION SERIES 1 3636 NVG1 3' - 6" 3' - 6" 7' - 2"6 VECTOR ENVISION SERIES 5 3650 NVPWG/3620 NVA1 TEMP. 3' - 6" 6' - 11 1/2" 8' - 0"7 VECTOR ENVISION SERIES 3 5040E NVG1 5' - 0" 4' - 0" 6' - 10"8 VECTOR ENVISION SERIES 2 5050E NVG1 5' - 0" 5' - 0" 6' - 10"9 VECTOR ENVISION SERIES 1 6050E NVG1 6' - 0" 5' - 0" 6' - 10"10 VECTOR ENVISION SERIES 1 8040E NVGE 8' - 0" 4' - 0" 6' - 10"1/2" = 1'-0"A-5013TYP. COLUMNROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOOR AREA PLATE HEIGHT COMMENTSLOWER FLOOR FAMILY ROOM CARPET 504 SF 8' - 2" .LOWER FLOOR BEDROOM #5 CARPET 174 SF 8' - 2" .LOWER FLOOR CLOSET CARPET 95 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 80 SF 8' - 2"LOWER FLOOR MECHANICAL CONCRETE 201 SF 8' - 2" FINISH PER CODELOWER FLOOR BATH VINYL 48 SF 8' - 2" .MAIN FLOOR GREAT ROOM CARPET 222 SF 10' - 1 1/8" 10' PLATEMAIN FLOOR OFFICE CARPET 134 SF 9' - 1 1/8" 12" BOX VAULTMAIN FLOOR STAIRWAY CARPET 82 SF 9' - 1 1/8"MAIN FLOOR GARAGE CONCRETE 627 SF 10' - 9 3/8"MAIN FLOOR PORCH CONCRETE 113 SF 9' - 1 1/8" .MAIN FLOOR MUD ROOM VINYL 86 SF 9' - 1 1/8" .MAIN FLOOR PWDR. VINYL 26 SF 9' - 1 1/8" .MAIN FLOOR PANTRY VINYL 35 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 238 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM WOOD 170 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 136 SF 9' - 1 1/8" .UPPER FLOOR BEDROOM #4 CARPET 163 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 159 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 174 SF 8' - 1 1/8" VAULTEDUPPER FLOOR HALL CARPET 202 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 138 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 84 SF 8' - 1 1/8" .UPPER FLOOR EN SUITE L.V.T. 95 SF 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 58 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 44 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 2/4 x 6/8 2' - 6" 6' - 11" 72 2/4 x 6/8 PKT 4' - 10" 6' - 11" 13 2/6 x 6/8 2' - 8" 6' - 11" 74 2/6 x 6/8 PKT 5' - 2" 6' - 11" 15 2/8 x 6/8 2' - 10" 6' - 11" 26 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 17 2/8 x 6/8 FULL VIEW 2' - 10 1/2" 6' - 10 1/4" 18 3/0 x 6/8 OPG. 19 3/0 x 6/8 W/ 2-12" D.S. S.L.'S & 12" TRANSOM 110 5/0 x OPG. TO CEILING 111 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 112 8' x 8' O.H. GARAGE DOOR 113 16' x 8' O.H. GARAGE DOOR 1 6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLAN3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER0' - 8"FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTAL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONDRYVIT INSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 5TOTAL:RELEASED 11/9/2023 1:09:05 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-502OTT361123912548778'-1 1/8"9'-1 1/8"8'-4" POUR10.26.23 CB11 9.23 CB9.29.23 CB34704.19.23 CBTHE PAYTON XL1/2" = 1'-0"A-5021TYP. WALKOUT SECTION1/2" = 1'-0"A-5022TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5023TYP. HOUSE/GARAGE WALL3/8" = 1'-0"A-5024METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5025BEARING WALL SECTION1/2" = 1'-0"A-5026TYP. LOOKOUT SECTION MAIN FLOOR1' -8 1/4"UPPER PLATE20' -11 1/4"UPPER PLATE20' -11 1/4"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -10 1/8"LOWER PLATE0' -1 1/2"GREAT ROOM PLATE11' -9 3/8"GREAT ROOM PLATE HEIGHT 10' - 1 1/8"24" FLOOR TRUSSES18" FLOOR TRUSSESEN SUITECLOSETBEDROOM #2DINING ROOMGREAT ROOMFAMILY ROOMMAIN FLOOR PLATE HEIGHT 9' - 1 1/8"1' - 0"UPPER PLATE HEIGHT 8' - 1 1/8"MFG. ROOF TRUSSES 12" FLOOR TRUSSESTILE SHOWER FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP. FASTENKING STUD TO HEADERW/ 6-16d SINKERS.MIN. 7/16" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).FRONT ELEVATIONMIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 7/16" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INFRAMING (STUDS AND SILLS) AS SHOWN TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALEXTENT OF HEADER WITH DOUBLE PORTAL FRAMES (TWO BRACED WALL PANELS)BRACED WALL LINECONTINUOUSLYSHEATHED WITH WOODSTRUCTURAL PANELS.OVERLAP0' - 9 1/4" MIN.WOOD STRUCTURAL PANEL SHEATHINGCONTINUOUS OVER BAND OR RIM JOISTNAIL SOLE PLATE TO JOISTPER TABLE R602.3(1)WOOD STRUCTURAL PANEL SHEATHING OVER APPROVED BAND OR RIM JOISTATTACH SHEATHING TOBAND OR RIM JOIST WITH8d COMMON NAILS @3" O.C. TOP @ BOTTOMTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:PLATE HEIGHTSUPPER:MAIN:POUR:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONREV. 6REV. 7REV. 8REV. 9REV. 5TOTAL:RELEASED 11/9/2023 1:09:06 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-503OTT361123912548778'-1 1/8"9'-1 1/8"8'-4" POUR10.26.23 CB11 9.23 CB9.29.23 CB34704.19.23 CBTHE PAYTON XL1/4" = 1'-0"A-5031GREAT ROOM SECTION3/8" = 1'-0"A-5032METHOD CS-PF - RAISED WOOD W/ OVERLAP MAIN FLOOR1' -8 1/4"UPPER PLATE20' -11 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -10 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"ALUMINUM SOFFIT& FASCIA TYP.6" SMARTSIDEFRIEZE BOARD TYP.VINYL BOARD &BATTEN TYP.VINYL LAP SIDING & VINYL CORNERS ALL SIDESCULTURED STONE W/CONCRETE CAP4" SMARTSIDE TRIM@ WINDOWS & DOORSTYP. -FRONT ONLYADDRESS STONE6" SMARTSIDE STORYBOARD TYP.4' - 6"22020 NVFA1R.O. 2' -0" x 2' -0"H.H. 2' -6"SEE COLUMN DETAIL SHEET A-5017" / 12"4" / 12"8" 12"GARAGE PLATE HEIGHT10' - 9 3/8"8" 12"GREAT ROOM PLATE11' -9 3/8"10' - 1 1/8"1/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/29/2023 12:23:00 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-201OTT3614.20.23 CB123912548774.26.23 CB5.23.23 CB6.22.23 CB9.29.23 CB4.19.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3470THE PAYTON XLSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONA-202 ELEVATIONSA-401 FOUNDATION PLANA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 ROOF/ WINDOW SCHEDULEA-502 DETAILSA-503 SECTION 24" RETURNSTYPICAL7" 12"7" / 12"8" / 12"8" / 12"8" / 12"7" / 12"MAIN FLOOR1' -8 1/4"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING& CORNERS @SIDES & REAR7" / 12"7" 12"GREAT ROOM PLATE11' -9 3/8"8" 12"10' - 1 1/8"7" 12"24" RETURNSTYPICAL7" 12"4" 12"8" / 12"8" / 12"7" / 12"STANDARD ENERGY HEELS @ 7:12W/ 8:12 TO MATCH FASCIA LINE18" OVERHANGS & 12" RAKES TYP.7 ROOF VENTS @ HOUSE4 ROOF VENTS @ GARAGE7" / 12"8" / 12"8" / 12"8" / 12"8" / 12"7" / 12"7" / 12"4" / 12"STANDARD ENERGY HEELS @ 4:12 W/ 8:12 TO MATCH FASCIA LINES7" / 12"7" / 12"1 ROOF VENTS7" / 12"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/29/2023 12:23:03 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-202OTT3614.20.23 CB123912548774.26.23 CB5.23.23 CB6.22.23 CB9.29.23 CB4.19.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3470THE PAYTON XL1/8" = 1'-0"A-2021RIGHT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023LEFT ELEVATION1/8" = 1'-0"A-2024ROOF PLAN 54' - 0"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"50' - 0"34' - 2"19' - 10"14' - 0"5' - 10"28' - 2"6' - 0"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE19' - 8"24' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE54' - 0"15' - 8 1/4"3' - 4 1/2"4' - 5 1/4"4' - 5 1/4"16' - 0 3/4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.31' - 6"22' - 6"44' - 0"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"26' - 4"14' - 9 3/4"0' - 8 1/4"12' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2' - 0"20' - 6"25' - 6"6' - 0"1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.44' - 0"6' - 0"3' - 11"7' - 9"20' - 8"LEAVE A 12" GAP IN FOOTINGFOR PLUMBING:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE50' - 0"2' - 3 1/4"8' - 5 1/2"5' - 3 1/4"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY0' - 4"7' - 0 3/4"12' - 7 1/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY17' - 0"11' - 0"16' - 0"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/29/2023 12:23:03 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-401OTT3614.20.23 CB123912548774.26.23 CB5.23.23 CB6.22.23 CB9.29.23 CB4.19.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3470THE PAYTON XL1/4" = 1'-0"A-4011FOUNDATION PLAN UNEXCAVATEDSUMPW. H.F. D.4' VANITYFAMILY ROOMBEDROOM #5BATH6' - 0"25' - 6"22' - 6"1' - 10"19' - 10"20' - 2"11' - 0"18' - 10"31' - 2"6' - 0"28' - 2"19' - 10"15' - 10"5' - 10"4' - 8"CO DET.18" FLOOR TRUSSESPER MFG. SPACING19' - 3 1/2"4' - 2 1/2"4' - 2 1/2"16' - 3 1/2"12/4 x 6/8R.O. 2' -6" x 6' -11"48" F.G. SHWR32/6 x 6/8R.O. 2' -8" x 6' -11"18" FLOOR TRUSSESPER MFG. SPACING14' - 0"5' - 10"12' - 8"15' - 6"UNEXCAVATED6' - 0"44' - 0" (BRACED WALL LINE SPACING)2x610' - 7"0' - 5"3' - 8"SMOKEDET.*3-1/2" CONC. FLOOR*MECHANICALS MAY VARY19' - 8"24' - 4"*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/SHEATHING2-2x10 W/2 TRIMMERS2-2x102-2x102-2x1050' - 0"44' - 0"4' - 3 1/4"7' - 4 3/4"3' - 11"10' - 9"0' - 4"14' - 8"11' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.4' - 2 1/2"15' - 1"3' - 6"52/8 x 6/8R.O. 2' -10" x 6' -11"MECHANICAL12/4 x 6/8R.O. 2' -6" x 6' -11"AIR EX.2" FOAM INSULATIONBETWEEN WALL & SLAB1' - 11 1/2"16' - 3" M.O.1' - 11 1/2"1' - 1 1/2"8' - 3" M.O.1' - 7 1/2"2' - 0"20' - 6"26' - 4"54' - 0"54' - 0"7' - 10"9' - 2"5' - 6"5' - 6"6' - 6"9' - 6"75040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"108040E NVGER.O. 8' -0" x 4' -0"H.H. 6' -10"32/6 x 6/8R.O. 2' -8" x 6' -11"50' - 0"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.2-9 1/2" LSLXXXX FLUSH3-9 1/2" LVL W/3 TRIMMERSCS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.15'-6" OF WALL BRACINGREQUIRED. BRACE TO FOUNDATIONOR UNTIL MINIMUM IS MET31' - 0" (BRACED WALL LINE SPACING)15'-6" OF WALL BRACINGREQUIRED. BRACE TO FOUNDATIONOR UNTIL MINIMUM IS MET0' - 4"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"17' - 0"11' - 0"16' - 0"CS-WSP2' - 6" B.W.P.SMOKEDET.2-9 1/2" LSLR & SH. @ 65CLOSETFURNACE1/4" = 1'-0"A-4021LOWER FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/29/2023 12:23:04 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-402OTT3614.20.23 CB123912548774.26.23 CB5.23.23 CB6.22.23 CB9.29.23 CB4.19.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3470THE PAYTON XL*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***H1H2[||[[|[[[[[[[[[[[||||2 - 2 x 10[[||3 - 2 x 10OKOKOKOK3 - 9-1/2" LSL2 - 11-7/8" LSL4-2x62 - Trimmers2-2x102-2x10 22' - 6"31' - 6"34' - 0"20' - 0"50' - 0"3/0 x 6/8 W/2-12" D.S.S.L.'S & 12"TRANSOM9KITCHENDINING ROOMFOYEROFFICE8" BOX VAULTDWGARAGEPORCH6' - 0"28' - 0"6' - 0"14' - 0"18' - 10"31' - 2"20' - 2"11' - 0"9' - 6"6' - 6"5' - 6"5' - 6"2' - 0"8' - 3"6' - 9"50' - 0"2' - 1"16' - 0"2' - 1"1' - 3"8' - 0"1' - 9"0' - 10"5' - 2"1' - 0"11' - 0"7' - 4"SMOKEDET.2-11 7/8" LSL4' - 2"4' - 0"12" CANT. ABOVE3' - 10"9' - 0"6' - 6"SEE COLUMN DETAIL SHEET A-5014' - 4"5' - 10"0' - 10"15' - 0"MFG. ROOF TRUSSES@ 24" O.C.2-9 1/2" LSL W/3 TRIMMERS2-2x10TYP.0' - 4 1/2"6' - 0"25' - 6"20' - 6"2' - 0"2-2x126' - 0"44' - 0"SNACK BAR19' - 4"4' - 0"1' - 4"CS-WSP3' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.SINK3/0 x 6/8OPG.82-2x102-11 7/8"LSL FLUSH W/3 TRIMMERS2-2x10 W/2 TRIMMERS2-2x10CS-WSP3' - 6" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.2-2x1054' - 0"3' - 2 3/4"5' - 6"3' - 2"12' - 2"19' - 5"5' - 0"7' - 5"12' - 6"15' - 6"19' - 3 1/2"4' - 2 1/2"4' - 2 1/2"16' - 3 1/2"2-2x1024" CANT. ABOVE26' - 0"14' - 8"10' - 0"KNEE WALL W/14" SPINDLES2-2x102-11 7/8"LSL FLUSH W/3 TRIMMERS2-11 7/8"LSL FLUSHW/ 2 TRIMMERS5/0 x OPG.TO CEILING109" HEAT DUCT2' - 0"2' - 0"14' - 10 7/8"2' - 8 1/2"10' - 4 5/8"EQEQ63650 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 6' -11 1/2"H.H. 8' -0"6653636 NVG1R.O. 3' -6" x 3' -6"H.H. 7' -2"43016 NVPWGR.O. 3' -0" x 1' -6"H.H. 8' -0"96050E NVG1R.O. 6' -0" x 5' -0"H.H. 6' -10"ATTICACCESSCS-WSP4' - 0" B.W.P.16" SH.16" SH.PAINTED CABINETSFULL TILE BACKSPLASH16' x 8' O.H.GARAGEDOOR138' x 8' O.H.GARAGEDOOR1254' - 0"CS-WSP5' - 0" B.W.P.PANTRY4' - 4"2' - 8"4' - 4"GAS LINE FOR RANGE1' - 0"55" LINEAR ELEC. F.P.2' - 0"11' - 4"14' - 8"24" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.FRAME BOTTOM OFWINDOW @ 44" A.F.F.HHUS484" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. CEILING1/2" GYP. BD. ON GARAGE WALLS GARAGE PLATE HEIGHT TO MATCHMAIN FLOOR UNLESS NOTED OTHERWISEPFH1' - 9"PFH2' - 1"PFH2' - 1"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES17' - 0"11' - 0"16' - 0"A-50312x62' - 8"2' - 11"5' - 9"12/4 x 6/8R.O. 2' -6" x 6' -11"MUD ROOM30" GAS COOKTOPW/ WOOD HOODABOVE OVEN/MICROPWDR.36" REFTYP.2' - 0"6' - 0"GREAT ROOM10' PLATESET FIREPLACE @ F.F.HALF HIGH STONE WRAPPED TO EXTERIOR WALL W/ WRAPPED MANTELCS-WSP2' - 8" B.W.P.XXXX FLUSH10'-1 1/8" PLATE HAND FRAME CEILING DOWN FOR ANGLE CEILING ABOVE 24" FLOOR TRUSSESPER MFG. SPACING9' CEILING CEILING STEPS TO 10'CEILING STEPS TO 10'9' CEILING 62/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"MFG. ROOF TRUSSES@ 24" O.C.22/4 x 6/8 PKTR.O. 4' -10" x 6' -11"PED. SINK12" FLOOR TRUSSESPER MFG. SPACING72/8 x 6/8 FULL VIEWR.O. 2' -10 1/2" x 6' -10 1/4"6624" CANT. ABOVE 24' - 8"BRACED WALL DESIGN WILL BE UPDATED WHENPLAN IS FINISHED CS-PF1' - 9" B.W.P.CS-PF1' - 9" B.W.P.3' - 11 3/4"43016 NVPWGR.O. 3' -0" x 1' -6"H.H. 8' -0"1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/29/2023 12:23:05 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-403OTT3614.20.23 CB123912548774.26.23 CB5.23.23 CB6.22.23 CB9.29.23 CB4.19.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3470THE PAYTON XL*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***||[[[[||||[[[||OK2 - 2 x 102 - 2 x 102 - 2 x 10OKOKOK11.50 ft OKOKB1B2B3B4B52 - 2 x 10OK10.50 ft OKOKOK[||[[|[[[[[[[[[[[||||||||||||2 - 9-1/2" LSL Cont.4-2x6 From AboveOKHGUS4122 - 11-7/8" LSLHHUS48OK3-2x6 LAUNDRYOWNER'S SUITEHALL1/2 WALL W/WOOD CAPSMOKEDET.SMOKEDET.6' VANITYCLOSETSMOKEDET.BEDROOM #2GIRDER TRUSSCO DET.SMOKEDET.ATTICACCESS2' LINEN13' - 0"31' - 0"3' - 0"28' - 0"29' - 0"2' - 0"16' - 0"28' - 0"16' - 0"5' - 7"14' - 11"7' - 6"6' - 6"6' - 6"2' - 6"8' - 0"20' - 6"VAULT LINE2-2x10 W/2 TRIMMERS2-2x102-2x102-2x10CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.44' - 0"5' - 9"22' - 3"44' - 0"13' - 5"7' - 10 1/2"3' - 4 1/2"4' - 4"7' - 0"4' - 3 1/2"5' - 4 1/2"5' - 6"5' - 10"4' - 0 3/4"2' - 8"2' - 10"4' - 3"2' - 6 1/2"12' - 1"2' - 6"3' - 8"9' - 4 3/4"19' - 3 1/2"4' - 2 1/2"4' - 2 1/2"16' - 3 1/2"4' - 4"5' - 0"1' - 8"17' - 0"2-2x1032020 NVFA2R.O. 4' -0" x 2' -0"H.H. 6' -10"85050E NVG1R.O. 5' -0" x 5' -0"H.H. 6' -10"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"85050E NVG1R.O. 5' -0" x 5' -0"H.H. 6' -10"75040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"KNEE WALL W/14" SPINDLESMFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACINGEN SUITE3-2x6A-503131' - 0"31' - 0"13' - 7 1/4"2' - 6"32/6 x 6/8R.O. 2' -8" x 6' -11"32/6 x 6/8R.O. 2' -8" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"5' TUB/SHWR3' VANITYSMOKEDET.GIRDER TRUSS52/8 x 6/8R.O. 2' -10" x 6' -11"4:12 3-2x632/6 x 6/8R.O. 2' -8" x 6' -11"10' - 8"1' - 8"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"6' - 0 1/2"22' - 11 1/2"MFG. ROOF TRUSSESPER MFG. SPACING42/6 x 6/8 PKTR.O. 5' -2" x 6' -11"GIRDER TRUSSROUGH IN SINKBEDROOM #3BEDROOM #4R & SH. @ 65BATH2x6R & SH. @ 66 WIRER & SH. @ 65WASHERDRYER32/6 x 6/8R.O. 2' -8" x 6' -11"4' - 3 1/2"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES712/4 x 6/8R.O. 2' -6" x 6' -11"12' - 5"32/6 x 6/8R.O. 2' -8" x 6' -11"3' x 5' TUB W/ 4" TILEDECK3' - 5"0' - 4"2' - 4"CURBTILE SHOWER 42" WALL W/ GLASS PANEL DBL: FRAMETHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/29/2023 12:23:06 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-404OTT3614.20.23 CB123912548774.26.23 CB5.23.23 CB6.22.23 CB9.29.23 CB4.19.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3470THE PAYTON XL1/4" = 1'-0"A-4041UPPER FLOOR PLANMFG Roof Trussesby OthersMFG Roof Trussesby OthersMFG Roof Trussesby Others*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***OKOK2 - 2 x 102 - 2 x 10OKOKOK12.24 ftOK OK4-2x64-2x6||[[[[||||[[[[||13.75 ft|||||||||||| WATCH DOG WATER PROOF COATINGFROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/29/2023 12:23:07 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-501OTT3614.20.23 CB123912548774.26.23 CB5.23.23 CB6.22.23 CB9.29.23 CB4.19.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3470THE PAYTON XL3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:3/8" = 1'-0"A-5012TYP. WALL SECTIONWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 VECTOR ENVISION SERIES 2 2020 NVA1 2' - 0" 2' - 0" 6' - 10"2 VECTOR ENVISION SERIES 1 2020 NVFA1 2' - 0" 2' - 0" 2' - 6"3 VECTOR ENVISION SERIES 1 2020 NVFA2 4' - 0" 2' - 0" 6' - 10"4 VECTOR ENVISION SERIES 2 3016 NVPWG 3' - 0" 1' - 6" 8' - 0"5 VECTOR ENVISION SERIES 1 3636 NVG1 3' - 6" 3' - 6" 7' - 2"6 VECTOR ENVISION SERIES 5 3650 NVPWG/3620 NVA1 TEMP. 3' - 6" 6' - 11 1/2" 8' - 0"7 VECTOR ENVISION SERIES 3 5040E NVG1 5' - 0" 4' - 0" 6' - 10"8 VECTOR ENVISION SERIES 2 5050E NVG1 5' - 0" 5' - 0" 6' - 10"9 VECTOR ENVISION SERIES 1 6050E NVG1 6' - 0" 5' - 0" 6' - 10"10 VECTOR ENVISION SERIES 1 8040E NVGE 8' - 0" 4' - 0" 6' - 10"1/2" = 1'-0"A-5013TYP. COLUMNROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOOR AREA PLATE HEIGHT COMMENTSLOWER FLOOR FAMILY ROOM CARPET 508 SF 8' - 2" .LOWER FLOOR BEDROOM #5 CARPET 174 SF 8' - 2" .LOWER FLOOR CLOSET CARPET 95 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 76 SF 8' - 2"LOWER FLOOR MECHANICAL CONCRETE 201 SF 8' - 2" FINISH PER CODELOWER FLOOR BATH VINYL 48 SF 8' - 2" .MAIN FLOOR GREAT ROOM CARPET 222 SF 10' - 1 1/8" 10' PLATEMAIN FLOOR OFFICE CARPET 134 SF 9' - 1 1/8" 8" BOX VAULTMAIN FLOOR STAIRWAY CARPET 88 SF 9' - 1 1/8"MAIN FLOOR GARAGE CONCRETE 627 SF 10' - 9 3/8"MAIN FLOOR PORCH CONCRETE 113 SF 9' - 1 1/8" .MAIN FLOOR MUD ROOM VINYL 86 SF 9' - 1 1/8" .MAIN FLOOR PWDR. VINYL 26 SF 9' - 1 1/8" .MAIN FLOOR PANTRY VINYL 35 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 239 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM WOOD 170 SF 9' - 1 1/8" .MAIN FLOOR FOYER WOOD 128 SF 9' - 1 1/8" .UPPER FLOOR BEDROOM #4 CARPET 163 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 159 SF 8' - 1 1/8" .UPPER FLOOR OWNER'S SUITE CARPET 174 SF 8' - 1 1/8" VAULTEDUPPER FLOOR HALL CARPET 202 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 138 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 84 SF 8' - 1 1/8" .UPPER FLOOR EN SUITE L.V.T. 95 SF 8' - 1 1/8" .UPPER FLOOR LAUNDRY VINYL 58 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 44 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 2/4 x 6/8 2' - 6" 6' - 11" 72 2/4 x 6/8 PKT 4' - 10" 6' - 11" 13 2/6 x 6/8 2' - 8" 6' - 11" 74 2/6 x 6/8 PKT 5' - 2" 6' - 11" 15 2/8 x 6/8 2' - 10" 6' - 11" 26 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 17 2/8 x 6/8 FULL VIEW 2' - 10 1/2" 6' - 10 1/4" 18 3/0 x 6/8 OPG. 19 3/0 x 6/8 W/ 2-12" D.S. S.L.'S & 12"TRANSOM110 5/0 x OPG. TO CEILING 111 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 112 8' x 8' O.H. GARAGE DOOR 113 16' x 8' O.H. GARAGE DOOR 1 6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLAN3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER0' - 8"FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTAL2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONDRYVIT INSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/29/2023 12:23:08 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-502OTT3614.20.23 CB123912548774.26.23 CB5.23.23 CB6.22.23 CB9.29.23 CB4.19.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3470THE PAYTON XL1/2" = 1'-0"A-5021TYP. WALKOUT SECTION1/2" = 1'-0"A-5022TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5023TYP. HOUSE/GARAGE WALL3/8" = 1'-0"A-5024METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/2" = 1'-0"A-5025BEARING WALL SECTION1/2" = 1'-0"A-5026TYP. LOOKOUT SECTION MAIN FLOOR1' -8 1/4"UPPER PLATE20' -11 1/4"UPPER PLATE20' -11 1/4"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -10 1/8"LOWER PLATE0' -1 1/2"GREAT ROOM PLATE11' -9 3/8"GREAT ROOM PLATE HEIGHT 10' - 1 1/8"24" FLOOR TRUSSES18" FLOOR TRUSSESEN SUITECLOSETBEDROOM #2DINING ROOMGREAT ROOMFAMILY ROOMMAIN FLOOR PLATE HEIGHT 9' - 1 1/8"1' - 0"UPPER PLATE HEIGHT 8' - 1 1/8"MFG. ROOF TRUSSES 12" FLOOR TRUSSESTILE SHOWER THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302 BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMUNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:9/29/2023 12:23:09 PMTHE MOHAMUD RESIDENCEL8, B3 - KNOB HILL 2ND ADD'N5818 178TH STREET WESTLAKEVILLE, MN 55044A-503OTT3614.20.23 CB123912548774.26.23 CB5.23.23 CB6.22.23 CB9.29.23 CB4.19.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3470THE PAYTON XL1/4" = 1'-0"A-5031GREAT ROOM SECTION RIBBON BLOCK FORDECKFLUSH (2) 2X10FLUSH (2) 2X10PAINTED ENDPAINTED END18" DEEP TRUSSES24" O.C. BASE SPACING.DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING. TRUSSES HAVE BEEN HELD IN1/2" AT EXTERIOR WALLS FOR SHEATHING.THE PAINTED END DENOTES THE LEFT ENDOF THE FLOOR TRUSS. THIS END OF THEFLOOR TRUSS IS TO BE PLACED WHERE YOUSEE THE TRIANGLE AND THE PAINTED ENDNOTE ON THE PLACEMENT PLAN. THEPAINTED END ALSO CORRESPONDS TO THELEFT SIDE OF THE SEALED TRUSS DRAWING.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBINGLOCATIONS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLJOSH @ 651-287-1944OREMAIL: JRUDESILL@VILLAUME.COMF3F13F10F2F2F1F1F1F1F1F4F16F16F16F16F16F7F8F9F9F9F9F1F11F11F14F12F15F15F5F6F6F6F6F9F9F17F17LUS410LUS41015-06-0019-03-08 4-02-08 4-02-0814-08-002-00-0026-00-0034-00-0028-00-0024-08-0019-04-0044-00-0010-02-0016-00-00 11-00-00 17-00-006-00-006-00-001-08-082-00-002-00-002-00-002-00-0010-041-07-041-06-082-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-00Customer: Lyman Lumber - ChanhassenJob Number: 325749-CHome Owner: TOPAZ / PAYTON XL / MOHAMUD RESJob Name: 1st FloorSite Address: 5818 178TH ST W Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Josh Rudesill2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date:10/25/2023Version: 8.5.3.233 BLUE HATCHED WALLRAISED 1' FROM MAINPLATEFLUSH 2-PLY 11-7/8" LVLFLUSH (2) 2X10PAINTED ENDPAINTED ENDFLUSH 2-2x10 EXTENDRIGHT END24" DEEP TRUSSES24" O.C. BASE SPACING.DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING. TRUSSES HAVE BEEN HELD IN1/2" AT EXTERIOR WALLS FOR SHEATHING.THE PAINTED END DENOTES THE LEFT ENDOF THE FLOOR TRUSS. THIS END OF THEFLOOR TRUSS IS TO BE PLACED WHERE YOUSEE THE TRIANGLE AND THE PAINTED ENDNOTE ON THE PLACEMENT PLAN. THEPAINTED END ALSO CORRESPONDS TO THELEFT SIDE OF THE SEALED TRUSS DRAWING.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBINGLOCATIONS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLJOSH @ 651-287-1944OREMAIL: JRUDESILL@VILLAUME.COMFLUSH 2-PLY 11-7/8" LVLFUR UP TO 10-01-02FF2FF11FF1FF1FF1FF1FF1FF12FF16FF16FF16FF5FF5FF6FF7FF8FF9FF9FF10FF10FF10FF1FF16XFF4FF3FF3FF3FF17FF19FF10FF10FF13FF15FF15FF15FF15FF13FF14FF10FF18FF18FF9THA422HUC410HUC41015-06-0012-02-0019-03-08 3-08-08 3-08-0810-02-009-04-0014-08-006-00-002-00-0020-06-0025-06-0054-00-0020-00-0028-00-002-00-0011-00-0020-02-0018-10-006-00-0016-00-0050-00-0010-0013-00-006-04-002-00-0020-08-001-00-0017-00-006-00-0028-00-006-00-0011-00-001-08-082-00-002-00-002-00-002-00-0010-041-07-041-06-082-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-0010-001-04-002-00-008-00Customer: Lyman Lumber - ChanhassenJob Number: 325749-BHome Owner: TOPAZ / PAYTON XL / MOHAMUD RESJob Name: 2nd FloorSite Address: 5818 178TH ST W Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Josh Rudesill2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date:10/25/2023Version: 8.5.3.233 2x4 LEDGERDIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING.THE TRUSS ID DOES NOT DENOTE THE LEFTEND OF THE ROOF TRUSS ON THEPLACEMENT PLAN. USE THE LEFT END OFTHE SEALED TRUSS DRAWING AND THETRIANGLE ON THE PLACEMENT PLAN TOLOCATE THE PROPER END OF EACH ROOFTRUSS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLJOSH @ 651-287-1944OREMAIL: JRUDESILL@VILLAUME.COMD= 3791#U= 289#D= 6058#U= 396#D= 10640#U= 487#D= 10508#U= 462#u=292d=2430u=334d=2736C1A2A1A1A1A1A1A3A3A3A3A3M2M2M2M2M2M2M1M1M1M1L1M3N2N1N16-00-001-10-082-00-002-00-002-00-0020-06-0025-06-0054-00-0020-00-0028-00-0011-00-0020-02-0018-10-006-00-0016-00-0050-00-001-11-042-00-002-00-002-00-002-00-002-00-0010-0013-00-00 6-04-002-00-0020-08-001-00-0017-00-006-00-0028-00-006-00-0011-00-00H2H1D9D8D8D8D8D8D8D6D5D1D1D1D1D1D7H4H3H3H3H3H3H3E1E2D2D2D2D3D3D2D2D2D4V1V2V3V4V5V9FV8FV7FV6FV12BV11BV10BTBE6HUS26HUS26HUS26LUS28LUS28LUS28HUS26LUS28HUS26HUS26LUS28HUS26HUS26HUS26HUS26HUS26HUS26HHUS28-2JL210IF-TZLUS281-11-042-00-002-00-002-00-002-00-002-00-002-00-002-00-082-00-001-11-042-00-00Customer: Lyman Lumber - ChanhassenJob Number: 325749-CHome Owner: TOPAZ / PAYTON XL / MOHAMUD RESJob Name: 1st FloorSite Address: 5818 178TH ST W Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Josh Rudesill2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date:10/25/2023Version: 8.5.3.233 Date Certificate Posted X Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here R-15 X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: 70,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93 Cfm's " round duct OR " metal duct Not required per mech. code X Passive Low: Other, describe: X Low: Location of fan(s), describe: Cfm's X " round duct OR 7" flex " metal duct ML19307016B Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 250 Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: 160 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 26610Residential Load Calculation SEER /EER Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 Building envelope air tightness: Rim Joist (1st Floor) GPVL5000L 13ACX024P Model Heating System Natural Gas Lennox Fiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.21 Describe other insulated areas Fiberglass, BlownTHERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not Applicable Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.28 Appliances Mechanical room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 60333 Heating Gain Cooling Load 80 Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.11/9/2023 New Construction Energy Code Compliance Certificate Name of Residential Contractor One Ten Ten Homes, LLC MN License Number Lakeville5818 178th Street W BC730925 City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 2 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 * If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to erosion@lakevillemn.gov “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA)