Loading...
HomeMy WebLinkAboutLA220280 - 17724 Ellsworth Drive - Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND MAIN FLOOR930.4'MAIN PLATE939.5'MAIN PLATE939.5'T.O. HOUSE FOUNDATION928.7'T.O. HOUSE FOUNDATION928.7'MAIN PLATE HEIGHT9' - 1 1/8"GARAGE PLATE HEIGHT11' - 6 3/8"VINYL SIDING &CORNERS TYP.6" SMARTSIDESTORYBOARDTYP. @ FRONTALUMINUM SOFFIT& FASCIA TYP.VINYL BOARD & BATTEN TYP. 6" SMARTSIDEFRIEZE TYP.UPPER FLOOR941.0'UPPER PLATE949.1'UPPER PLATE HEIGHT8' - 1 1/8"6" BUMPED OUT LOUVER 66" x 22" W/ 6" CORBELS3' - 6"6" / 12"6" / 12"6" / 12"3" / 12"T.O. GARAGE FOUNDATION928.0'0' - 9"8" 12"ADDRESS STONE 24" RETURNS6" 12"8" / 12"8" / 12"3" 12"6" 12"VINYL SIDING& CORNERS TYP.ALUMINUM SOFFIT& FASCIA TYP.6" / 12"6" / 12"6" / 12"8" 12"6" 12"8" / 12"24" RETURNS8" / 12"8" / 12"1/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/14/2023 4:38:57 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'N17724 ELLSWORTH DRIVELAKEVILLE, MN 55044A-201OTT41011.2.23 CB8701761111111.7.23 CB11.14.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3742THE SADIE1/8" = 1'-0"A-2012RIGHT ELEVATION1/4" = 1'-0"A-2013REAR ELEVATION1/8" = 1'-0"A-2014LEFT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONSA-401 FOUNDATIONA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 DETAILS/ SCHEDULESA-502 DETAILS/ SECTION 13' - 10"5' - 2"21' - 0"10' - 0"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE 10' - 0"40' - 0"64' - 0"13' - 10"50' - 2"1' - 4 1/2"8' - 3" M.O.0' - 4 1/2"1' - 4 1/2"18' - 3" M.O.1' - 4 1/2"19' - 10"20' - 2"6' - 2"14' - 0"6' - 0"0' - 4"0' - 4"0' - 4"64' - 0"36' - 4"7' - 10"10' - 4"4' - 2 1/4"4' - 2 3/4"4' - 2 3/4"19' - 4 1/4"5' - 5"6' - 11"12' - 7 3/4"19' - 4 1/4"10' - 9 1/4"10' - 7 3/4"0' - 7 1/4"5' - 4 1/2"12' - 7 1/4"20' - 9 3/4"6' - 7"1' - 2 1/2"11' - 4 3/4"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 17" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 3 1/2" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.0' - 4"2' - 0"26' - 6"28' - 6"35' - 6"31' - 0"19' - 0"50' - 0"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.50' - 0"2' - 0"5' - 10"6' - 0"0' - 4":WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 3 1/2" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.35' - 2"SITE VERIFY15' - 0"TOP OF GARAGE FOUNDATION WALL TO MATCH TOP OF HOUSE FOUNATION WALLTOP OF GARAGE FOUNDATION TO DROP 9" FROM THE TOP OF HOUSE FOUNDATION19' - 6 3/4"0' - 7 3/4"18' - 8 1/2"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY0' - 4"13' - 10"0' - 2"5' - 8"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/14/2023 4:38:58 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'N17724 ELLSWORTH DRIVELAKEVILLE, MN 55044A-401OTT41011.2.23 CB8701761111111.7.23 CB11.14.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3742THE SADIE1/4" = 1'-0"A-4011FOUNDATION PLAN ** ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/ SHEATHING FAMILY ROOMBEDROOM #5MECHANICAL/STORAGEBATHSUMPW. H.FURNACEAIR EX.UNEXCAVATED18" FLOOR TRUSSESPER MFG. SPACINGSTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACINGUNEX.13' - 10"5' - 2"21' - 0"10' - 0"FLEX ROOM10' - 0"40' - 0"6' - 5 3/8"13' - 6 5/8"13' - 9 7/8"6' - 2 1/8"CLOSET32/6 x 6/8R.O. 2' -8" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"24" LINEN22/4 x 6/8R.O. 2' -6" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"3' VANITY45040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"45040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"SMOKEDET.SMOKEDET.CO DET.36' - 4"64' - 0"6' - 0"6' - 2"14' - 0"20' - 2"6' - 0"64' - 0"13' - 10"50' - 2"14' - 9"4' - 0"4' - 0"19' - 7"11' - 0"3' - 10"5' - 10"19' - 4"R & SH.R & SH.KNEE WALL W/ 14" SPINDLES 15' - 3"6' - 7"12' - 0"16' - 0"3' - 8"8' - 4"16' - 11 3/4"19' - 4 1/4"19' - 4 1/4"5' - 5 1/2"7' - 2 1/4"12' - 4"42/8 x 6/8R.O. 2' -10" x 6' -11"5' - 6"4' - 2"11' - 3"19' - 6 3/4"19' - 4 1/4"FLOORDRAIN13' - 10"0' - 2"5' - 8"31' - 0"19' - 0"0' - 4"0' - 4"0' - 4"0' - 4"32/6 x 6/8R.O. 2' -8" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"8' - 4"3' - 8"R & SH.CLOSETBEDROOM #4EQEQ5' - 0"36" GAS. F.P.2' - 0"BUILT-INBUILT-IN60" F.G. SHWRBASE W/ TILEWALLSSMOKEDET.50' - 0"28' - 6"35' - 6"2' - 0"26' - 6"32/6 x 6/8R.O. 2' -8" x 6' -11"2" FOAM INSULATION BETWEEN WALL & SLAB 50' - 0"14' - 0"1' - 0"4' - 4 1/4"5' - 5 1/2"4' - 4 1/4"1' - 0"14' - 0"2-11 7/8" LVL W/ 2TRIMMERS DROPPED 0' - 4"5' - 10"2' - 0"TOP OF GARAGE FOUNDATION TO DROP 9" FROM THE TOP OF HOUSE FOUNDATION2x62-2-x102-2x102-2x10 W/ 2 TRIMMERS 2-9 1/2" LSL 2-2x10 W/ 2 TRIMMERS CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES7' - 10"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.40' - 0" (BRACED WALL LINE SPACING)50' - 0" (BRACED WALL LINE SPACING)10.4' OF BRACED WALL REQUIRED 10.4' OF BRACED WALL REQUIRED 12.6' OF BRACED WALL REQUIRED CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP8' - 0" B.W.P.CS-WSP4' - 0" B.W.P.10.4' OF WALL BRACING REQUIRED, BRACE TO FOUNDATION OR UNTIL MINIMUM IS MET THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/14/2023 4:39:00 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'N17724 ELLSWORTH DRIVELAKEVILLE, MN 55044A-402OTT41011.2.23 CB8701761111111.7.23 CB11.14.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3742THE SADIE1/4" = 1'-0"A-4021LOWER FLOOR PLAN 1318' x 8' O.H. GARAGE DOOR8' VANITY.PRIMARY SUITEGREAT ROOMDININGKITCHENBATHFOYERGARAGECO DET.SMOKEDET.SMOKEDET.ATTICACCESSMUDRM.LAUNDRY10' - 0"21' - 0"5' - 6"13' - 6"CLOSET36" REF10' - 0"40' - 0"14' - 0"50' - 0"1' - 6"8' - 0"0' - 6"1' - 6"18' - 0"1' - 6"36" COOKTOPW/ WOODHOOD ABOVESINK20' - 6"6' - 6"14' - 0"DW5' - 0"24"x14" LINEN28' - 6"35' - 6"64' - 0"2x612/4 SHWR DR.2' - 0"EQEQ53/0 x 6/8R.O. 3' -2" x 6' -11"83/0 x 6/8 PKTR.O. 6' -2" x 6' -11"95/0 x 6/8R.O. 5' -2" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"53/0 x 6/8R.O. 3' -2" x 6' -11"63/0 x 6/8 FIRE RATEDR.O. 3' -2" x 6' -10 1/4"BENCHW/ HOOKS6' - 0"4' - 0"3' - 0"4' - 0"11' - 8"6' - 11 1/4"13' - 5 3/4"9' - 11"36" GAS. F.P.R & SH.2'-6" VANITYR & SH.6' - 0"6' - 9"6' - 9"56050E NVG1R.O. 6' -0" x 5' -0"H.H. 6' -10"BOTTOM OF WINDOW FRAMED @ 44" A.F.F 3333640 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 5' -11 1/2"H.H. 8' -0"7' - 0"15' - 4 1/8"12' - 1 7/8"5' - 6"CO DET.SMOKEDET.42" WALL W/ GLASS PANEL ABOVE R & SH.R & SH.TILE SHOWER R & SH.R & SH.SINK14' - 9 3/4"21' - 2 1/4"64' - 0"6' - 0"2A-50215' - 0"6' - 6"3' - 10 3/4"3' - 10"6' - 9 1/4"PRIMARYCLOSET6' - 4"3' - 4"4' - 2"11' - 0"3' - 10"5' - 10"0' - 10"18' - 6"14' - 5"4' - 0"4' - 0"19' - 7"5' - 11 1/2"5' - 4 1/2"5' - 4"4' - 2"6' - 1"4' - 1"9' - 0"53/0 x 6/8R.O. 3' -2" x 6' -11"4' - 6"9' - 0"12' - 7"2' - 6"6' - 6 1/2"BEDROOM #253/0 x 6/8R.O. 3' -2" x 6' -11"KNEE WALL W/ 14" SPINDLES 53/0 x 6/8R.O. 3' -2" x 6' -11"BUILT-INBUILT-IN4" CONCRETE SLAB, SLOPETOWARDS DOOR5/8" TYPE X GYP. BD. CEILING 1/2" GYP. BD. ON GARAGE WALLS R-38 MIN. INSULATION IN FLOOR ABOVEGARAGE PLATE HEIGHT TO BE11' -6 3/8"2x678050E NVGER.O. 8' -0" x 5' -0"H.H. 6' -10"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 8' -0"116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"23636 NVG1R.O. 3' -6" x 3' -6"H.H. 7' -2"MFG. ROOF TRUSSESPER MFG. SPACING53/0 x 6/8R.O. 3' -2" x 6' -11"SMOKEDET.6' - 4 1/4"0' - 11"6' - 11"ATTICACCESS20' - 7 1/4"29' - 4 3/4"EN SUITE3' - 3"2' - 9"0' - 9"4' - 0"0' - 9"2' - 0"COVEREDENTRYSNACK BAR OVEN/MICRO31' - 0"19' - 0"5' TUB/SHWR53/0 x 6/8R.O. 3' -2" x 6' -11"53/0 x 6/8R.O. 3' -2" x 6' -11"6' - 0"36' - 0"2' - 0"26' - 6"128' x 8' O.H. GARAGE DOOR50' - 0"73/0 x 6/8 HALF VIEW2' - 6"3' - 6"2x62x6STACK W/DCOUNTER W/BASE6' - 7"6' - 7 1/2"2' - 6"2x6ADDITIONAL STEPS IN WALK TO DRIVEWAYVERIFY ON SITE 2-2x102-9 1/2" LSLMFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACING2-9 1/2" LSL W/ 2 TRIMMERS 2-2x102-2x8 DROP2-2x102-2x10 W/2 TRIMMERS 2-11 7/8" LVL 2-2x122-2x102-2x102-2x102-2x10GIRDER TRUSS ROOM IN ATTIC-GIRDER TRUSS 3-2x63-2x63-2x6GIRDER TRUSS 3-2x63-2x63-2x63-2x63-2x618" FLOOR TRUSSESPER MFG. SPACINGCS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES50' - 0"19' - 6"8' - 0"ROOM-IN-ATTIC TRUSSESPER MFG. SPACINGROOM -IN ATTIC TRUSSESPER MFG. SPACINGROOM IN ATTIC-GIRDER TRUSS ROOM IN ATTIC-GIRDER TRUSS TYP.0' - 3"46' - 0" (BRACED WALL LINE SPACING)18' - 0" (BRACED WALL LINE SPACING)40' - 0" (BRACED WALL LINE SPACING)10' - 0" (BRACED WALL LINE SPACING)35' - 6" (BRACED WALL LINE SPACING)28' - 6" (BRACED WALL LINE SPACING)19' - 0" (BRACED WALL LINE SPACING)31' - 0" (BRACED WALL LINE SPACING)8.0' OF BRACED WALL REQUIRED 6.1' OF BRACED WALL REQUIRED 6.1' OF BRACED WALL REQUIRED 5.8' OF BRACED WALL REQUIRED 18.2' OF BRACED WALL REQUIRED 9.0' OF BRACED WALL REQUIRED 8.0' OF BRACED WALL REQUIRED 8.0' OF BRACED WALL REQUIRED 6.1' OF BRACED WALL REQUIRED 9.0' OF BRACED WALL REQUIRED 7.1' OF BRACED WALL REQUIRED 5.8' OF BRACED WALL REQUIRED PFH1' - 6"PFH1' - 6"PFH1' - 6"CS-WSP3' - 9" B.W.P.CS-WSP3' - 9" B.W.P.METHOD G.B.14' - 0" BOTH SIDES CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 6" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.ROOM-IN-ATTIC TRUSSESPER MFG. SPACING20' - 0"1' - 4"6' - 5"1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/14/2023 4:39:02 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'N17724 ELLSWORTH DRIVELAKEVILLE, MN 55044A-403OTT41011.2.23 CB8701761111111.7.23 CB11.14.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3742THE SADIE 11' - 0"18' - 0"11' - 0"22/4 x 6/8R.O. 2' -6" x 6' -11"FLAT VAULT FLAT VAULT 2A-5023' VANITY60" F.G. SHWRBASE W/ TILEWALLS67636 NVGER.O. 7' -6" x 3' -6"H.H. 6' -10"BATHLOFT40' - 0"11' - 0"18' - 0"11' - 0"4' - 0"4' - 0"6' - 0"36' - 0"18' - 5"4' - 0"4' - 0"19' - 7"11' - 0"3' - 10"5' - 10"19' - 4"CO DET.SMOKEDET.18' - 2 1/4"8' - 2 3/4"5' - 7 1/4"9' - 0"4' - 11 3/4"KNEE WALL W/ 14" SPINDLES 9' - 0"9' - 0"50' - 0"4' - 0"46' - 0"67636 NVGER.O. 7' -6" x 3' -6"H.H. 6' -10"32/6 x 6/8R.O. 2' -8" x 6' -11"FLAT VAULT FLAT VAULT SMOKEDET.BEDROOM #3HALL9' - 0"9' - 0"2x6 KNEE WALL W/ 14" SPINDLES 2x640' - 0"1' - 7"9' - 3"3' - 8"2' - 6"1' - 0"95/0 x 6/8R.O. 5' -2" x 6' -11"5'-8" +/-KNEE WALL TYP. 6'-6" +/-WALLR & SH.DOOR STOPRESILIENT CHANNEL SYSTEM ON CEILING TYP. 2-2x102-2x10ROOM IN ATTIC-GIRDER TRUSS ROOM IN ATTIC-GIRDER TRUSS MFG. ROOF TRUSSESPER MFG. SPACING50' - 0"ROOM-IN-ATTIC TRUSSESPER MFG. SPACINGROOM-IN-ATTIC TRUSSESPER MFG. SPACINGCS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES46' - 0" (BRACED WALL LINE SPACING)4.2' OF BRACED WALL REQUIRED 4.2' OF BRACED WALL REQUIRED THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/14/2023 4:39:03 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'N17724 ELLSWORTH DRIVELAKEVILLE, MN 55044A-404OTT41011.2.23 CB8701761111111.7.23 CB11.14.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3742THE SADIE1/4" = 1'-0"A-4041UPPER FLOOR PLAN 6" / 12"6" / 12"18" OVERHANGS & 12" RAKES TYP.14" HEELS @ 8:12 SLOPE6:12 FASCIA LINES TO MATCH SEE SECTION ON A-5028" / 12"8" / 12"8" / 12"8" / 12"6" / 12"6" / 12"3" / 12"ICE AND WATER ENTIRE AREA 6" / 12"6" / 12"8" / 12"8" / 12"WATER PROOF COATINGFROM GRADE TO TOPOF FOOTING6 MIL POLY V.B., OVERLAP EDGESMIN. 12" & TAPE. SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" RIGID (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSINSULATION & SEALANT TOBE CONT. OVER WALLMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER FLOOR PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.6 MIL. V.B.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" PLYWOODSHEATHINGSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" PLYWOOD SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGE2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATIONRIM JOISTR-20 MIN. SPRAYFOAM INSULATION2" RIGID (R-10)INSULATION*OUTSIDE OF CONCRETEFOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGINSULATION PROTECTION FROMUNDER SIDING TO BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANS1' - 5"ALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSS2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/14/2023 4:39:05 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'N17724 ELLSWORTH DRIVELAKEVILLE, MN 55044A-501OTT41011.2.23 CB8701761111111.7.23 CB11.14.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3742THE SADIEWINDOW SCHEDULEWINDOW MARK UNIT MANUFACTURER MODEL COUNT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT COMMENTS1 2020 NVA1 VECTOR ENVISION SERIES 1 2' - 0" 2' - 0" 8' - 0"2 3636 NVG1 VECTOR ENVISION SERIES 1 3' - 6" 3' - 6" 7' - 2"3 3640 NVPWG/3620 NVA1 TEMP. VECTOR ENVISION SERIES 3 3' - 6" 5' - 11 1/2" 8' - 0"4 5040E NVG1 VECTOR ENVISION SERIES 2 5' - 0" 4' - 0" 6' - 10"5 6050E NVG1 VECTOR ENVISION SERIES 1 6' - 0" 5' - 0" 6' - 10"6 7636 NVGE VECTOR ENVISION SERIES 2 7' - 6" 3' - 6" 6' - 10"7 8050E NVGE VECTOR ENVISION SERIES 1 8' - 0" 5' - 0" 6' - 10"ROOM FINISH SCHEDULEFLOOR ROOM NAME FLOOR FINISH AREA PLATE HEIGHT COMMENTSLOWER FLOOR BEDROOM #4 148 SF 8' - 2"LOWER FLOOR CLOSET 36 SF 8' - 2"LOWER FLOOR CLOSET 36 SF 8' - 2"LOWER FLOOR BEDROOM #5 155 SF 8' - 2"LOWER FLOOR FAMILY ROOM 395 SF 8' - 2"LOWER FLOOR FLEX ROOM 148 SF 8' - 2"LOWER FLOOR STAIRS 77 SF 8' - 2"LOWER FLOOR MECHANICAL/ STORAGE CONCRETE 522 SF 8' - 2"FINISH PER CODELOWER FLOOR BATH TILE 54 SF 8' - 2"MAIN FLOOR CLOSET 36 SF 9' - 1 1/8"MAIN FLOOR LAUNDRY 60 SF 9' - 1 1/8"MAIN FLOOR BATH 48 SF 9' - 1 1/8"MAIN FLOOR BEDROOM #2 170 SF 9' - 1 1/8"MAIN FLOOR COVERED ENTRY 33 SF 9' - 1 1/8"MAIN FLOOR DINING 116 SF 9' - 1 1/8"MAIN FLOOR EN SUITE 57 SF 9' - 1 1/8"MAIN FLOOR FOYER 155 SF 9' - 1 1/8"MAIN FLOOR GREAT ROOM 294 SF 9' - 1 1/8"MAIN FLOOR KITCHEN 232 SF 9' - 1 1/8"MAIN FLOOR MUDRM. 59 SF 9' - 1 1/8"MAIN FLOOR PRIMARY CLOSET 54 SF 9' - 1 1/8"MAIN FLOOR PRIMARY SUITE 188 SF 9' - 1 1/8"MAIN FLOOR GARAGE CONCRETE 721 SF 11' - 6 3/8" FINISH PER CODEUPPER FLOOR BATH 45 SF 8' - 1 1/8"UPPER FLOOR BEDROOM #3 239 SF 8' - 1 1/8"UPPER FLOOR HALL 105 SF 8' - 1 1/8"UPPER FLOOR LOFT 316 SF 8' - 1 1/8"DOOR SCHEDULE R/O'STYPE MARK DOOR SIZE COUNT ROUGH WIDTH ROUGH HEIGHT COMMENTS1 2/4 SHWR DR. 12 2/4 x 6/8 5 2' - 6" 6' - 11"3 2/6 x 6/8 4 2' - 8" 6' - 11"4 2/8 x 6/8 2 2' - 10" 6' - 11"5 3/0 x 6/8 8 3' - 2" 6' - 11"6 3/0 x 6/8 FIRE RATED 1 3' - 2" 6' - 10 1/4"7 3/0 x 6/8 HALF VIEW 18 3/0 x 6/8 PKT 1 6' - 2" 6' - 11"9 5/0 x 6/8 2 5' - 2" 6' - 11"11 6/0 x 6/8 SLIDER 2 6' - 0" 6' - 8"12 8' x 8' O.H. GARAGE DOOR 113 18' x 8' O.H. GARAGE DOOR 11/8" = 1'-0"A-5011ROOF PLAN3/8" = 1'-0"A-5012TYP. POURED WALL SECTION,1/2" = 1'-0"A-5013TYP. POURED WALKOUT SECTION1/2" = 1'-0"A-5014TYP. POURED LOOKOUT SECTION1/2" = 1'-0"A-5015TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5016TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-50110GARAGE CEILING1/2" = 1'-0"A-5019BEARING WALL SECTION FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALMAIN PLATE939.5'UPPER FLOOR941.0'UPPER PLATE949.1'KNEE WALL HEIGHT 5' - 8 13/16"1' - 6 3/4"KNEE WALL HEIGHT 5' - 8 13/16"18" BOTTOM CHORD ROOM-IN-ATTIC TRUSSES UPPER PLATE HEIGHT 8' - 1 1/8"EN SUITEGREAT ROOMKITCHENBATH8" 12"8" 12"HEELS 1' - 2"VERIFY HEELS W/ TRUSS SUPPLIER HALL1' - 0"1' - 0 "6' - 9 3/32"1' - 6 3/4"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/14/2023 4:39:06 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'N17724 ELLSWORTH DRIVELAKEVILLE, MN 55044A-502OTT41011.2.23 CB8701761111111.7.23 CB11.14.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3742THE SADIE3/8" = 1'-0"A-5021METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/4" = 1'-0"A-5022BUILDING SECTION3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM: 18" DEEP TRUSSES24" O.C. BASE SPACING.DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING. TRUSSES HAVE BEEN HELD IN1/2" AT EXTERIOR WALLS FOR SHEATHING.THE PAINTED END DENOTES THE LEFT ENDOF THE FLOOR TRUSS. THIS END OF THEFLOOR TRUSS IS TO BE PLACED WHERE YOUSEE THE TRIANGLE AND THE PAINTED ENDNOTE ON THE PLACEMENT PLAN. THEPAINTED END ALSO CORRESPONDS TO THELEFT SIDE OF THE SEALED TRUSS DRAWING.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBINGLOCATIONS.EXTRA TRUSSES ADDED FOR PLUMBING.SHIFT TRUSSES TO AVOID PLUMBING.DO NOT OVER SPACE TRUSSES.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLANDY @ 651-688-3613OREMAIL: AHOERNEMANN@VILLAUME.COMF1F2F2F2F2F2F2F2F2F2F3F10F3F10F3F10F3F10F3F10F4F4F4F4F4F5F15F16F15F6F7F7F7F7F7F8F9F9F9F11F11F12F12F12F13F4F14F725-02-045-05-08 19-04-0450-00-0013-06-00 6-00-00 14-00-00 6-06-0019-04-0416-07-1236-00-006-00-002-00-006-00-0040-00-008-00-00 8-00-00 8-00-00 8-00-00 8-00-00Customer: Lyman Lumber - ChanhassenJob Number: 325852-AHome Owner: TOPAZ / SADIE / L37, B1 MODELJob Name: RoofSite Address: 17724 ELLSWORTH DR Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Andy Hoernemann2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date:11/13/2023Version: 8.5.3.233 NEED HEADER HEREHAND FRAMESADDLE(3) LUS24<--- (9) LUS24 --->A3A2AAAAAAAAA1AAAAA1GE1EEEEEE2E3DDDDK1KKKKKKD1D1D1D1K2K2K2H1CCCC1C2C3HHHLH2H2H2V1BV2BV3V4V5V6V7V8V9V14V15V16V17V18V10FV11FV12FV13FV5V6V7V8V9P1PPPPPPPPPPPPPPPPPPPPP140-00-0010-00-0050-00-0014-00-0010-00-0021-00-005-06-0013-06-002-00-00 26-06-0035-06-00Customer: Lyman Lumber - ChanhassenJob Number: 325852-AHome Owner: TOPAZ / SADIE / L37, B1 MODELJob Name: RoofSite Address: 17724 ELLSWORTH DR Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Andy Hoernemann2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date:11/13/2023Version: 8.5.3.233 MAIN FLOOR930.4'MAIN PLATE939.5'MAIN PLATE939.5'T.O. HOUSE FOUNDATION928.7'T.O. HOUSE FOUNDATION928.7'MAIN PLATE HEIGHT9' - 1 1/8"GARAGE PLATE HEIGHT11' - 6 3/8"VINYL SIDING &CORNERS TYP.6" SMARTSIDESTORYBOARDTYP. @ FRONTALUMINUM SOFFIT& FASCIA TYP.VINYL BOARD & BATTEN TYP. 6" SMARTSIDEFRIEZE TYP.UPPER FLOOR941.0'UPPER PLATE949.1'UPPER PLATE HEIGHT8' - 1 1/8"6" BUMPED OUT LOUVER 66" x 22" W/ 6" CORBELS3' - 6"6" / 12"6" / 12"6" / 12"3" / 12"T.O. GARAGE FOUNDATION928.0'0' - 9"24" RETURNS6" 12"8" / 12"8" / 12"3" 12"6" 12"VINYL SIDING& CORNERS TYP.ALUMINUM SOFFIT& FASCIA TYP.6" / 12"6" / 12"6" / 12"8" 12"6" 12"8" / 12"24" RETURNS8" / 12"8" / 12"1/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 1:14:06 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'NA-201OTT41011.2.23 CB8701761120911.7.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3876THE SADIE1/8" = 1'-0"A-2012RIGHT ELEVATION1/4" = 1'-0"A-2013REAR ELEVATION1/8" = 1'-0"A-2014LEFT ELEVATION 13' - 10"5' - 2"21' - 0"10' - 0"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE 10' - 0"40' - 0"64' - 0"13' - 10"50' - 2"1' - 4 1/2"8' - 3" M.O.0' - 4 1/2"1' - 4 1/2"18' - 3" M.O.1' - 4 1/2"19' - 10"20' - 2"6' - 2"14' - 0"6' - 0"0' - 4"0' - 4"0' - 4"64' - 0"36' - 4"7' - 10"10' - 4"4' - 2 1/4"4' - 2 3/4"4' - 2 3/4"19' - 4 1/4"12' - 4"7' - 2 1/4"5' - 5 1/2"19' - 4 1/4"10' - 9 1/4"10' - 7 3/4"0' - 8 1/4"5' - 3 1/2"12' - 7 1/4"20' - 9 3/4"7' - 9 1/2"11' - 4 3/4"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 17" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 3 1/2" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.0' - 4"2' - 0"26' - 6"28' - 6"35' - 6"31' - 0"19' - 0"50' - 0"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.50' - 0"2' - 0"5' - 10"6' - 0"0' - 4"13' - 10"0' - 2":WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 3 1/2" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.35' - 2"SITE VERIFY15' - 0"TOP OF GARAGE FOUNDATION WALL TO MATCH TOP OF HOUSE FOUNATION WALLTOP OF GARAGE FOUNDATION TO DROP 9" FROM THE TOP OF HOUSE FOUNDATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 1:14:07 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'NA-401OTT41011.2.23 CB8701761120911.7.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3876THE SADIE1/4" = 1'-0"A-4011FOUNDATION PLAN ** ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/ SHEATHING FAMILY ROOMBEDROOM #5MECHANICAL/STORAGEBATHSUMPW. H.FURNACEAIR EX.UNEXCAVATED18" FLOOR TRUSSESPER MFG. SPACING2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACINGUNEX.13' - 10"5' - 2"FLEX ROOM10' - 0"40' - 0"6' - 5 3/8"13' - 6 5/8"13' - 9 7/8"6' - 2 1/8"CLOSET32/6 x 6/8R.O. 2' -8" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"24" LINEN22/4 x 6/8R.O. 2' -6" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"3' VANITY45040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"45040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"SMOKEDET.SMOKEDET.CO DET.36' - 4"64' - 0"6' - 0"6' - 2"14' - 0"20' - 2"6' - 0"64' - 0"13' - 10"50' - 2"14' - 9"4' - 0"4' - 0"19' - 7"11' - 0"3' - 10"5' - 10"19' - 4"R & SH.R & SH.KNEE WALL W/ 14" SPINDLES 15' - 3"6' - 7"12' - 0"3' - 8"8' - 4"16' - 11 3/4"19' - 4 1/4"19' - 4 1/4"5' - 5 1/2"7' - 2 1/4"12' - 4"42/8 x 6/8R.O. 2' -10" x 6' -11"5' - 6"4' - 2"25' - 4 1/4"5' - 5 1/2"19' - 4 1/4"FLOORDRAIN5' - 10"10' - 0"21' - 0"19' - 0"0' - 4"0' - 4"0' - 4"0' - 4"32/6 x 6/8R.O. 2' -8" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"8' - 4"3' - 8"R & SH.CLOSETBEDROOM #4EQEQ5' - 0"36" GAS. F.P.2' - 0"BUILT-INBUILT-IN60" F.G. SHWRBASE W/ TILEWALLSSMOKEDET.50' - 0"28' - 6"35' - 6"2' - 0"26' - 6"11' - 3"14' - 1 1/4"32/6 x 6/8R.O. 2' -8" x 6' -11"13' - 10"0' - 2"2" FOAM INSULATION BETWEEN WALL & SLAB 50' - 0"14' - 0"1' - 0"4' - 4 1/4"5' - 4 1/4"14' - 0"DROPPED HEADER 0' - 4"2' - 0"TOP OF GARAGE FOUNDATION TO DROP 9" FROM THE TOP OF HOUSE FOUNDATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 1:14:09 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'NA-402OTT41011.2.23 CB8701761120911.7.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3876THE SADIE1/4" = 1'-0"A-4021LOWER FLOOR PLAN 1318' x 8' O.H. GARAGE DOOR8' VANITY.PRIMARY SUITEGREAT ROOMDININGKITCHENBATHFOYERGARAGECO DET.SMOKEDET.SMOKEDET.ATTICACCESSMUDRM.LAUNDRY10' - 0"21' - 0"5' - 6"13' - 6"CLOSET36" REF10' - 0"40' - 0"14' - 0"50' - 0"1' - 6"8' - 0"0' - 6"1' - 6"18' - 0"1' - 6"36" COOKTOPW/ WOODHOOD ABOVESINK20' - 6"6' - 6"14' - 0"DW5' - 0"24"x14" LINEN28' - 6"35' - 6"64' - 0"2x612/4 SHWR DR.2' - 0"EQEQ53/0 x 6/8R.O. 3' -2" x 6' -11"83/0 x 6/8 PKTR.O. 6' -2" x 6' -11"95/0 x 6/8R.O. 5' -2" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"53/0 x 6/8R.O. 3' -2" x 6' -11"63/0 x 6/8 FIRE RATEDR.O. 3' -2" x 6' -10 1/4"BENCHW/ HOOKS6' - 0"4' - 0"3' - 0"4' - 0"11' - 8"6' - 11 1/4"13' - 5 3/4"9' - 11"36" GAS. F.P.R & SH.2'-6" VANITYR & SH.6' - 0"6' - 9"6' - 9"56050E NVG1R.O. 6' -0" x 5' -0"H.H. 6' -10"BOTTOM OF WINDOW FRAMED @ 44" A.F.F 3333640 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 5' -11 1/2"H.H. 8' -0"7' - 0"15' - 4 1/8"12' - 1 7/8"5' - 6"CO DET.SMOKEDET.42" WALL W/ GLASS PANEL ABOVE R & SH.R & SH.TILE SHOWER R & SH.R & SH.SINK14' - 9 3/4"21' - 2 1/4"64' - 0"6' - 0"2A-50215' - 0"6' - 6"3' - 10 3/4"2' - 6"1' - 4"6' - 9 1/4"PRIMARYCLOSET6' - 4"3' - 4"4' - 2"11' - 0"10' - 6"18' - 6"14' - 5"4' - 0"4' - 0"19' - 7"5' - 11 1/2"5' - 4 1/2"5' - 4"4' - 0"6' - 3"4' - 1"9' - 0"53/0 x 6/8R.O. 3' -2" x 6' -11"4' - 6"9' - 0"12' - 7"2' - 6"6' - 6 1/2"BEDROOM #253/0 x 6/8R.O. 3' -2" x 6' -11"KNEE WALL W/ 14" SPINDLES 53/0 x 6/8R.O. 3' -2" x 6' -11"BUILT-INBUILT-IN4" CONCRETE SLAB, SLOPETOWARDS DOOR5/8" TYPE X GYP. BD. CEILING 1/2" GYP. BD. ON GARAGE WALLS R-38 MIN. INSULATION IN FLOOR ABOVEGARAGE PLATE HEIGHT TO BE11' -6 3/8"2x678050E NVGER.O. 8' -0" x 5' -0"H.H. 6' -10"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 8' -0"116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"23636 NVG1R.O. 3' -6" x 3' -6"H.H. 7' -2"MFG. ROOF TRUSSESPER MFG. SPACING53/0 x 6/8R.O. 3' -2" x 6' -11"SMOKEDET.6' - 4 1/4"0' - 11"6' - 11"ROOM -IN ATTIC TRUSSESPER MFG. SPACINGROOM -IN ATTIC TRUSSESPER MFG. SPACINGATTICACCESS20' - 7 1/4"29' - 4 3/4"EN SUITE3' - 3"2' - 9"0' - 9"4' - 0"0' - 9"2' - 0"COVEREDENTRYSNACK BAR OVEN/MICRO50' - 0"5' TUB/SHWR53/0 x 6/8R.O. 3' -2" x 6' -11"53/0 x 6/8R.O. 3' -2" x 6' -11"6' - 0"36' - 0"2' - 0"26' - 6"128' x 8' O.H. GARAGE DOOR50' - 0"73/0 x 6/8 HALF VIEW2' - 6"3' - 6"2x62x6STACK W/DCOUNTER W/BASE6' - 7"6' - 7 1/2"2' - 6"2x6ADDITIONAL STEPS IN WALK TO DRIVEWAYVERIFY ON SITE 1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 1:14:11 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'NA-403OTT41011.2.23 CB8701761120911.7.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3876THE SADIE 11' - 0"18' - 0"11' - 0"22/4 x 6/8R.O. 2' -6" x 6' -11"FLAT VAULT FLAT VAULT 2A-5023' VANITY60" F.G. SHWRBASE W/ TILEWALLS67636 NVGER.O. 7' -6" x 3' -6"H.H. 6' -10"BATHLOFT40' - 0"11' - 0"18' - 0"11' - 0"4' - 0"4' - 0"42' - 0"18' - 5"4' - 0"4' - 0"19' - 7"11' - 0"3' - 10"5' - 10"19' - 4"CO DET.SMOKEDET.18' - 2 1/4"8' - 2 3/4"5' - 7 1/4"9' - 0"4' - 11 3/4"KNEE WALL W/ 14" SPINDLES 9' - 0"9' - 0"50' - 0"4' - 0"46' - 0"67636 NVGER.O. 7' -6" x 3' -6"H.H. 6' -10"32/6 x 6/8R.O. 2' -8" x 6' -11"FLAT VAULT FLAT VAULT SMOKEDET.BEDROOM #3ROOM -IN ATTIC TRUSSESPER MFG. SPACINGROOM -IN ATTIC TRUSSESPER MFG. SPACINGHALL9' - 0"9' - 0"2x6 KNEE WALL W/ 14" SPINDLES 2x640' - 0"1' - 7"9' - 3"3' - 8"2' - 6"1' - 0"95/0 x 6/8R.O. 5' -2" x 6' -11"5'-8" +/-KNEE WALL TYP. 6'-6" +/-WALLR & SH.DOOR STOPRESILIENT CHANNEL SYSTEM ON CEILING TYP. THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 1:14:13 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'NA-404OTT41011.2.23 CB8701761120911.7.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3876THE SADIE1/4" = 1'-0"A-4041UPPER FLOOR PLAN 6" / 12"6" / 12"18" OVERHANGS & 12" RAKES TYP.14" HEELS @ 8:12 SLOPE6:12 FASCIA LINES TO MATCH SEE SECTION ON A-5028" / 12"8" / 12"8" / 12"8" / 12"6" / 12"6" / 12"3" / 12"ICE AND WATER ENTIRE AREA WATER PROOF COATINGFROM GRADE TO TOPOF FOOTING6 MIL POLY V.B., OVERLAP EDGESMIN. 12" & TAPE. SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" RIGID (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSINSULATION & SEALANT TOBE CONT. OVER WALLMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER FLOOR PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.6 MIL. V.B.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" PLYWOODSHEATHINGSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" PLYWOOD SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGE2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATIONRIM JOISTR-20 MIN. SPRAYFOAM INSULATION2" RIGID (R-10)INSULATION*OUTSIDE OF CONCRETEFOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGINSULATION PROTECTION FROMUNDER SIDING TO BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANS1' - 5"ALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSS2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 1:14:14 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'NA-501OTT41011.2.23 CB8701761120911.7.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3876THE SADIEWINDOW SCHEDULEWINDOW MARK UNIT MANUFACTURER MODEL COUNT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT COMMENTS1 2020 NVA1 VECTOR ENVISION SERIES 1 2' - 0" 2' - 0" 8' - 0"2 3636 NVG1 VECTOR ENVISION SERIES 1 3' - 6" 3' - 6" 7' - 2"3 3640 NVPWG/3620 NVA1 TEMP. VECTOR ENVISION SERIES 3 3' - 6" 5' - 11 1/2" 8' - 0"4 5040E NVG1 VECTOR ENVISION SERIES 2 5' - 0" 4' - 0" 6' - 10"5 6050E NVG1 VECTOR ENVISION SERIES 1 6' - 0" 5' - 0" 6' - 10"6 7636 NVGE VECTOR ENVISION SERIES 2 7' - 6" 3' - 6" 6' - 10"7 8050E NVGE VECTOR ENVISION SERIES 1 8' - 0" 5' - 0" 6' - 10"ROOM FINISH SCHEDULEFLOOR ROOM NAME FLOOR FINISH AREA PLATE HEIGHT COMMENTSNot Placed STORAGE NotPlaced0' - 0"LOWER FLOOR BEDROOM #4 148 SF 8' - 2"LOWER FLOOR CLOSET 36 SF 8' - 2"LOWER FLOOR CLOSET 36 SF 8' - 2"LOWER FLOOR BEDROOM #5 155 SF 8' - 2"LOWER FLOOR FAMILY ROOM 395 SF 8' - 2"LOWER FLOOR FLEX ROOM 148 SF 8' - 2"LOWER FLOOR STAIRS 77 SF 8' - 2"LOWER FLOOR MECHANICAL/ STORAGE CONCRETE 517 SF 8' - 2"FINISH PER CODELOWER FLOOR BATH TILE 54 SF 8' - 2"MAIN FLOOR CLOSET 36 SF 8' - 1"MAIN FLOOR LAUNDRY 59 SF 9' - 1 1/8"MAIN FLOOR BATH 48 SF 9' - 1 1/8"MAIN FLOOR BEDROOM #2 170 SF 9' - 1 1/8"MAIN FLOOR COVERED ENTRY 33 SF 9' - 1 1/8"MAIN FLOOR DINING 116 SF 9' - 1 1/8"MAIN FLOOR EN SUITE 57 SF 9' - 1 1/8"MAIN FLOOR FOYER 156 SF 9' - 1 1/8"MAIN FLOOR GREAT ROOM 294 SF 9' - 1 1/8"MAIN FLOOR KITCHEN 232 SF 9' - 1 1/8"MAIN FLOOR MUDRM. 59 SF 9' - 1 1/8"MAIN FLOOR PRIMARY CLOSET 54 SF 9' - 1 1/8"MAIN FLOOR PRIMARY SUITE 188 SF 9' - 1 1/8"MAIN FLOOR GARAGE CONCRETE 721 SF 9' - 6 3/8" FINISH PER CODEUPPER FLOOR BATH 45 SF 8' - 1 1/8"UPPER FLOOR BEDROOM #3 239 SF 8' - 1 1/8"UPPER FLOOR HALL 105 SF 8' - 1 1/8"UPPER FLOOR LOFT 316 SF 8' - 1 1/8"DOOR SCHEDULE R/O'STYPE MARK DOOR SIZE COUNT ROUGH WIDTH ROUGH HEIGHT COMMENTS1 2/4 SHWR DR. 12 2/4 x 6/8 5 2' - 6" 6' - 11"3 2/6 x 6/8 4 2' - 8" 6' - 11"4 2/8 x 6/8 2 2' - 10" 6' - 11"5 3/0 x 6/8 8 3' - 2" 6' - 11"6 3/0 x 6/8 FIRE RATED 1 3' - 2" 6' - 10 1/4"7 3/0 x 6/8 HALF VIEW 18 3/0 x 6/8 PKT 1 6' - 2" 6' - 11"9 5/0 x 6/8 2 5' - 2" 6' - 11"11 6/0 x 6/8 SLIDER 2 6' - 0" 6' - 8"12 8' x 8' O.H. GARAGE DOOR 113 18' x 8' O.H. GARAGE DOOR 11/8" = 1'-0"A-5011ROOF PLAN3/8" = 1'-0"A-5012TYP. POURED WALL SECTION,1/2" = 1'-0"A-5013TYP. POURED WALKOUT SECTION1/2" = 1'-0"A-5014TYP. POURED LOOKOUT SECTION1/2" = 1'-0"A-5015TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5016TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-50110GARAGE CEILING1/2" = 1'-0"A-5019BEARING WALL SECTION FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALMAIN PLATE939.5'UPPER FLOOR941.0'UPPER PLATE949.1'5' - 8 13/16"5' - 8 13/16"18" BOTTOM CHORD ROOM-IN-ATTIC TRUSSES UPPER PLATE HEIGHT 8' - 1 1/8"EN SUITEGREAT ROOMKITCHENBATH8" 12"8" 12"1' - 2"VERIFY HEELS W/ TRUSS SUPPLIER HALL1' - 0"1' - 0 "6' - 9 3/32"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 1:14:16 PMTHE SADIE LOFT MODELL37, B1 -PHEASANAT RUN 7TH ADD'NA-502OTT41011.2.23 CB8701761120911.7.23 CB10.12.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3876THE SADIE3/8" = 1'-0"A-5021METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/4" = 1'-0"A-5022BUILDING SECTION3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM: Date Certificate Posted X Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here R-15 X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: 70,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93 Cfm's " round duct OR " metal duct Not required per mech. code X Passive Low: Other, describe: X Low: Location of fan(s), describe: Cfm's X " round duct OR 6" flex " metal duct City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 2 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.11/13/2023 New Construction Energy Code Compliance Certificate Name of Residential Contractor One Ten Ten Homes, LLC MN License Number Lakeville17724 Ellsworth Drive BC730925 Mechanical room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 65064 Heating Gain Cooling Load 98 Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.28 Appliances THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not Applicable Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.21 Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) GPVL5000L 13ACX024P Model Heating System Natural Gas Lennox Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13 195 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 19661Residential Load Calculation SEER /EER Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: ML19307016B Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 250 Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 * If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to erosion@lakevillemn.gov “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA)