HomeMy WebLinkAboutLA220547 - Approved Plans - SolarRoger Gilb Solar DrawingsCOVER PAGECP 0.0PV SYSTEMAS INDICATEDScale:Project:Dakota ElectricEXISTINGINVISIMOUNTSITE MAP & PV LAYOUTELECTRICAL 1-LINE DIAGRAMATTACHMENT LAYOUTSYSTEM LABELING DETAILINVERTER DATA SHEETSHEET INDEXPROPERTY PLANRSD DATA SHEETMODULE DATA SHEETATTACHMENT DATA SHEETPV 1.0SYSTEM RATINGEQUIPMENT SUMMARYELECTRICAL INFORMATIONMAIN SERVICE PANEL BUS SIZE:MAIN SERVICE BREAKER SIZE:MOUNTING SYSTEM:BUILDING INFORMATIONCONSTRUCTION TYPE: V-BOCCUPANCY: R3ROOF:VICINITY MAP (SCALE: NTS)SATELLITE VIEW (SCALE: NTS)GENERAL NOTES1.All electrical materials shall be new and listed by recognizedelectrical testing laboratory Custom made equipment shall have complete test data submittedby the manufacturer attesting to its safety2.Outdoor equipment shall be NEMA 3R rated or equivalent3.All metallic equipment shall be grounded4.Contractor shall obtain electrical permits prior to installation andshall coordinate all inspections, testing commissioning andacceptance with the client, utility co. and city inspectors as needed.5.The electrical contractor shall verify the exact locations of servicepoints and service sizes with the serving utility company andcomply with all utility companies requirements.6.Drawings are diagrammatic only, routing of raceways shall beoption of the contractor unless otherwise noted and shall becoordinated with other trades.7.If the roof material or the roof structure not adequate for PVinstallation, call the engineer of record prior to installation. Thecontractor is responsible to verify that the roof is capable ofwithstanding the extra weight.8.If the distances for cable runs are different than shown, thecontractor shall notify the electrical engineer to validate the wiresize. Final drawings will be red-lined and updated as appropriate.9.Whenever a discrepancy in quality of equipment arises on thedrawing or specifications, the contractor shall be responsible forproviding and installing all materials and services required by thestrictest conditions noted on the drawings or in the specificationsto ensure complete compliance and longevity of the operablesystem required by the engineer of record.PHOTOVOLTAIC NOTES:1.Rooftop mounted photovoltaic panels and modules shall be tested,listed and identified by recognized testing laboratory2.Solar system shall not cover any plumbing or mechanical vents3.Modules and support structures shall be grounded unless racking has integrated ground.4.Removal of an interactive inverter or other equipment shall notdisconnect the bonding connection between the groundingelectrode conductor and the photovoltaic source and/or outputcircuit grounded conductors.5.All PV modules and associated equipment and wiring shall beprotected from physical damage.6.Live parts of PV source circuits and PV output circuits over 150v toground shall not be accessible to other than qualified persons while energized.7.Inverter is equipped with integrated DC disconnect, thus providingground fault protection8.All conductors shall be copper and 75 deg rated9.A single conductor shall be permitted to be used to perform themultiple functions of dc grounding, AC grounding and bondingbetween AC and DC systems.10.Non-current carrying metal parts of equipment shall be effectivelybonded together. Bond both ends of raceways.200A200ATHE INSTALLATION OF SOLAR ARRAYS ANDPHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITHTHE FOLLOWING CODES:·2023 National Electrical Code·2018 International Building Code·2018 International Residential Code·2020 Minnesota Residential Code·2020 Minnesota Building Code·2020 Minnesota Energy Code·2020 Minnesota Accessibility Code·2020 Minnesota State Fire Code·2018 International Fire Code·2018 International Energy Conservation Code·2018 Mechanical CodeAS ADOPTED BY THE STATE OF MINNESOTAALL OTHER ORDINANCE ADOPTED BY THELOCAL GOVERNING AGENCIESGOVERNING CODESSURGE PROTECTIONPLACARDDC 9.240 KW STCAC 6.930 KW STC22PV 2.0PV 3.1PV 3.2PV 4.0PV 5.0D 6.0D 7.0D 8.0D 9.0D 10.0D 11.0D 12.0D 13.0COVER PAGECP 0.0COMP. SHINGLETRUSS: 2 X 4 @ 24" O.C.22INVERTER CERTIFICATIONPV INSPECTION CHECKLISTUTILITYDrawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:MONITORING DATA SHEETRACKING DATA SHEETD 14.0 SUNPOWER R-SERIES 420 WATT MODULES ENPHASE IQ7XS MICROINVERTERSThese drawings are protected by copyright under US law. Any form ofreproduction is strictly prohibited without prior written approval from Engineerinc.Concept Approval ONLYSubject to Field InspectionInspectorDate2020MN BldgCode12/15/2023dmathews
............................................................................MSP... (E) Main Service PanelINDEXAC.....................(N) 60A Utility AC(N) MicroinverterNOTE: Conduit in attic shallbe minimum 18 inches from roof sheatingNote: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTNOTE: No clearance issueDistance between all equipments is maximum 10"(E) Main MeterMM.....................................SECONDARY INTERCONNECTION.............INVERTERINVERTER TYPE: Micro:___ Enphase IQ7XS MicroinvertersModel #IQ7XS-96-2-US(240V)Dakota ElectricTOTAL ROOF AREA: 3279TOTAL MODULE AREA: 48414.76% OF COVERAGESITE MAP & PVLAYOUTPV 1.0PV SYSTEMAS INDICATEDScale:Project:JB(N) Junction Box(N) Solar ModuleEMT Type ConduitFire Setback LineFMT type Conduit2222Drawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:EQUIPMENT ELEVATIONFrom roofPVSNOTE: Keep 3ft clearance from gas meter and AC unit4'PVS6(N) PV Monitoring System.....200APVS6SOLAR MODULES___SUNPOWER 420 WattModel #SPR-R-420MainMeterMainServicePanelUtilityACDisconnectPVS(N) 125A PV Sub Panel ........INSIDEOUTSIDEPerformanceMeterPM(N) Performance Meter.............10'MIDWESTT1220M(E) Midwest T1220......................18''
f
i
re se
tback
18'' fire setback18'' fire se
t
b
a
c
k
aaaaaaaaaababbbbbbbbbbIteri Ct WJBPVS6PVSACMMMSPPMSolar PV Array22- Sunpower 420W Modules22-Enphase IQ7XS MicroinvertersPitch: 23 DegOrientation: 162 DegMSCALE:1/16" = 1'-0" 180° 90° 270°0°SWNE
ELECTRICAL 1-LINEDIAGRAMPV 2.0PV SYSTEMAS INDICATEDScale:Project:Note: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDesign meet National Electric Code(NEC codes)22SYSTEM RATING AND DER POWER OUTPUTINVERTER: ENPHASE IQ7XSINVERTER MAXIMUM CONTINUOUS OUTPUT:315VASYSTEM POWER OUTPUT:ENPHASE MICROINVERTERS1 PHASE 315VAMAXIMUM OUTPUT CURRENT 1.31AAC PORT BACKFEED CURRENT 18ADC SHORT CIRCUIT CURRENT 6.5ADC 9.240 KW STCAC 6.930 KW STCDC 9.240 KW STCAC 6.930 KW STCDakota Electricx 315= 6930SECONDARY INTERCONNECTIONREFERENCE POINT OF APPLICABILITYEXISTING______ MAINSERVICEPANEL120/240V,1P, 3W200A125A PV SUB PANEL120/240V, NEMA 3RINSTALL (2)20APV 2-POLE C/B60A FUSED UTILITY ACDISCONNECT,WITH 40A FUSES VISIBLE-OPEN LOCKABLE,READILY ACCESSIBLE,NEMA3R, 120 / 240V(NEW)GECAdd 2nd Ground rod andtie it to the existing ground rod.EXISTINGNON CENTER _____MAIN C/BNOTE: Keep 3ft clearance from gas meter and AC unit2222200AWire Size90C wirerating12 AWGTHWN-2, THHNXHHW-2, USE-210 AWGTHWN-2, THHNXHHW-2, USE-38 AWGTHWN-2, THHNXHHW-2, USE-4304055Temperature rating ofConductors-Ambient Temp.(114-122F) NEC 310.15(B)(2)(a)Number of Current carrying Conductors NEC 310.15(B)(16)4-67-910-2020A Branch Circuit Rating30A Branch Circuit Rating30 x 0.82=24.640 x 0.82=32.855 x 0.82=45.124.6x0.80= 19.6832.8x0.80= 26.2445.1x0.80= 36.0824.6x0.70= 17.2232.8x0.70= 22.9645.1x0.70= 31.5724.6x0.50= 12.332.8x0.50= 16.445.1x0.50= 22.55YES- 6 or less current carryingconductors in the same conduitYES- 9 or less current carryingconductors in the same conduitYES- 20 or less current carryingconductors in the same conduitYES- 9 or less current carryingconductors in the same conduitYES- 3 or less current carryingconductors in the same conduitNOSurge ProtectionMNSPD-300-ACDrawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:AtticWall (4) #12 AWG THWN/THWN-2(1)#12 AWG GND3/4" EMT, 5 FEET(3) #6 AWG THWN/THWN-2(1) #6 AWG GND1" SCH 80 PVC, 2 FEET(E) MAIN METER120/240V,1P, 3WPVS6MONITORING SYSTEM1BRANCHCIRCUIT-A (1) J BOXNEMA3R14.41A1-PHASE MICRO-INVERTER UL1741211114.41A211BRANCHCIRCUIT-B (4) #12 AWG THWN/THWN-2(1)#12 AWG GND3/4" FMT, 20 FEETProduction CTsSUNPOWER R-SERIES 420 WATT MODULESENPHASE IQ7XS MICROINVERTERSSUNPOWER TRUNK CABLE(2) #12 AWG PV WIRE(1) #10 INTEGRATED GROUNDINGFREE IN THE AIR15 AGEC(E) GROUNDINGELECTRODE SYSTEMLine Side Tap28.82A28.82A(3) #6 AWG THWN/THWN-21" SCH 80 PVC, 2 FEET(E) MIDWESTT1220Consumption CTsLINELOADUTILITY PV METER PRODUCTION METERSOCKET LABELED IN ACCORDANCE WITHNEC AND AHJ REQUIRMENTS LOCATEDWITHIN 5' OF MAIN. INVERTER OUTPUTWIRED TO LOAD SIDE TERMINAL OFMETER 1 PHASE 3-WIRE 120/240V(1) #6 AWG GND
SYSTEMLABELING DETAILPV 3.1PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:PV ARRAYJ BOXPV SUB-PANELACDISCONNECTMAIN SERVICEPANELMETER233321716218135Note: LABELS SHALL COMPLY WITH NEC 690“Labels shall be weatherproof, durable and permanently mounted”Photovoltaic Power SourceLABEL 2CAUTION: SOLAR CIRCUITLABEL 3WARNINGELECTRIC SHOCK HAZARDTHE DC CONDUCTORS OF THISPHOTOVOLTAIC SYSTEM AREUNDERGROUND AND MAY BE ENERGIZEDLABEL 4WARNINGELECTRIC SHOCK HAZARDIF GROUND FAULT IS INDICATEDNORMALLY GROUNDED CONDUCTORSMAY BE UNDERGROUND AND ENERGIZEDLABEL 5WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONLABEL 6WARNINGELECTRIC SHOCK HAZARDDO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE AND LOADSIDES MAY BE ENERGIZED IN THE OPENPOSITIONDC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULESARE EXPOSED TO SUNLIGHTLABEL 7WARNINGLABEL 8TURN OF PHOTOVOLTAICAC DISCONNECT PRIOR TOWORKING INSIDE PANELDO NOT DISCONNECTUNDER LOADLABEL 9MAIN PV SYSTEMDISCONNECTLABEL 10MAIN PV SYSTEMAC DISCONNECTLABEL 11LABEL 12CAUTIONLABEL 13SOLAR ELECTRIC SYSTEMCONNECTEDWARNING-LABEL 14 DUAL POWER SOURCESECOND SOURCE IS PV SYSTEMCAUTIONLABEL 15PHOTOVOLTAIC SYSTEM CIRCUITIS BACKFEDLABEL 16PHOTOVOLTAIC AC DISCONNECTMAXIMUM AC OPERATING CURRENTMAXIMUM AC OPERATING CURRENTPHOTOVOLTAICLABEL 17UTILITY AC DISCONNECTPHOTOVOLTAICLABEL 18DC DISCONNECTNOMINAL OPERATING AC VOLTAGENOMINAL OPERATING AC FREQUANCYMAXIMUM AC POWERMAXIMUM AC CURRENTMAX OCERCURRENT DEVICE RATINGFOR AC MODULE PROTECTIONLABEL 19LABEL 20PV SYSTEM DC DISCONNECTOPERATING CURRENTOPERATING VOLTAGEMAXIMUM SYSTEM VOLTAGESHORT CIRCUIT CURRENTRATED MAX POWER-FONT CURRENTRATED MAX POWER-FONT VOLTAGEMAXIMUM SYSTEM VOLTAGESHORT CIRCUIT CURRENTMAX RATED OUTPUT CURRENT OFTHE CHARGE CONTROLLER IF INSTALLEDLABEL 21***ALL LABELS = RED THERMOPLASTIC/REFLECTIVE , Permanently mounted240VSOLAR DISCONNECT21SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR ELECTRICPV PANELS28.82AProduction MeterLABEL 1PerformanceMeter31
PLACARDPV 3.2PV SYSTEMAS INDICATEDScale:Project:CAUTIONPOWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:SERVICE 1 OF 2CAUTIONPOWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:SERVICE 2 OF 2NWES9880 Iteri Ct WLakeville, MN 550449880 Iteri Ct WLakeville, MN 55044Drawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:NWESPV SUB PANELPV MONITORING SYSTEMSERVICE POINT &UTILITY METERINGPV SYSTEM DISCONNECTFOR UTILITY OPERATIONSOLAR PV ARRAY PERFORMANCE METERMIDWEST T1220PV SUB PANELPV MONITORING SYSTEMSERVICE POINT &UTILITY METERINGPV SYSTEM DISCONNECTFOR UTILITY OPERATIONSOLAR PV ARRAY PERFORMANCE METERMIDWEST T1220
PROPERTY PLANPV 4.0PV SYSTEMAS INDICATEDScale:Project:.....................MSPMain Service PanelINDEXAC..................................Utility ACPVSPV Sub Panel ......................Main MeterMM..............................Solar Module...............Note: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDakota ElectricDrawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:PVS6PV Monitoring System............PM..................Performance MeterMMidwest T1220............................Iteri Ct WDrivewayPROPERTY LINEPVS6PVSACMMMSPPM298'-10"391'-6"304'-3"60'-11"61'-4"107'-10"MSCALE:1/32" = 1'-0" 180° 90° 270°0°SWNE
ATTACHMENTLAYOUTPV 5.0PV SYSTEMAS INDICATEDScale:Project:DESIGN CRITERIAModules:Max Distributed Load: 3 PSFPOINT LOAD CALCULATION PER ARRAYModule Weight (lbs)# Of Modules48.5Total Module Weight (lbs)Rack Weight (lbs)MicroInverters Weight (lbs)Total System Weight (lbs)# Of StandoffsMax Span Between Standoffs (in)Loading Per Standoff (lbs)Total Area (sq.ft.)Loading (PSF)1067213.452.361332.76444830.294842.75RAIL ATTACHMENTTRUSS: 2 X 4 @ 24" O.C.22221 Layer of .Plywood & Building FeltSolar Module6"AttachmentROOF SECTION DETAILTRUSS: 2 X 4 @ 24" O.C.COMP. SHINGLEPrior to the commencement of work, thecontractor shall verify the existing roof andframing conditions. Notify New@engineerinc.ioof any Discrepancies prior to startingconstruction. Prior to the commencement ofwork, the contractor shall inspect framing forany damage such as water damage, crackedframing, etc. and These Plans are stamped forstructural code compliance of the roof framingsupporting the proposed PV installationreference only. These plans are not stampedfor water leakage. PV modules, racking, andattachment components must followmanufacturer guidelines and requirements.Attachments to be installed in a staggeredorientation to properly distribute loads.Note: 24/ 7 Unescorted keyless access is to beprovided for ALL UTILITY EQUIPMENTDrawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:LightSpeed FlashingSupport BlockEPDM WASHERROOF ASSEMBLYPEGASUS COMP SHINGLE DETAILS19'13'
D 6.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:MONITORINGDATA SHEET
INVERTERDATA SHEETD 7.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:
RSDDATA SHEETD 8.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:
MODULEDATA SHEETD 9.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:
RACKINGDATA SHEETD 10.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:
ATTACHMENTDATA SHEETD 11.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:
D 12.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:SURGEPROTECTION
D 13.0PV SYSTEMAS INDICATEDScale:Project:INVERTERCERTIFICATIONDrawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:
PV INSPECTIONCHECKLISTD 14.0PV SYSTEMAS INDICATEDScale:Project:Drawn by: New@engineerinc.ioPhone: (310) 928-0938Project Name:Property Address:DATE CREATED:CONTRACTORWolf RIver ElectricAddress:101 Isanti ParkwayNE, Isanti, MN 55040Phone number: (763) 229-6662E-mail: contact@wolfriverelectric.com9880 Iteri Ct WLakeville, MN 55044REVISION DATE:REVISION DATE:REVISION DATE:REVISION DATE:Roger Gilb12/08/2023REVISION DATE:REVISION DATE:Wolf RIver ElectricLakeville, MN 550449880 Iteri Ct W