Loading...
HomeMy WebLinkAboutLA220807 - 17963 Headwaters Dr - Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND FIRST FLOORTOTAL3,498 SF2,128 SF--GARAGEBASEMENTFLOOR AREAFINISHED-1,370 SF689 SF758 SFUNFINISHED200 AMP SERVICEWALKOUT BASEMENTGARAGE LEFTSIDEWALK77 SFGARAGE SLABBASEMENT SLABFLATWORK SQUARE FOOTAGE1,998 SF752 SFHIGHVIEW RIDGELOT 2, BLOCK 5 17963 HEADWATERS DRIVEROCKY & KARMYN FOSTERHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"E9'-6"F5'-0"2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDLAKEVILLE, MN 55044G10'-0"2018 BUILDING CODE2020 ENERGY CODEFRAMERS - MAKE SURE THERE IS ICE & WATER SHIELD BEHIND PORCH FRAMERS - 1/2" SHEATHING SHOULD BE FLUSH WITH CONCRETE& DECK LEDGERSCOUNTRY JOE SERIESEXTERIOR FOUNDATION INSULATION9'-0" TALL FOUNDATION WALLS2'-8"6'-312"LINE OFLINE OFFIREPLACESHEETROCK5'-0"FIREPLACE / ENTERTAINMENT CENTERSCALE: 1/4" = 1'-0"1'-5"BUILT-IN3'-134"3'-134"36X18 FIXED6'-0"BUILT-IN6'-0"3'-6" 1'-5"6'-312"1'-7"3'-412"3'-112"5'-834"5'-834"12'-118"36X18 FIX.A-015'-0" TALLBUILT-INSTONE1'-1"BUILT-INMANTLE HEIGHTBUILT-INMANTLE HEIGHT5'-0"BOLT W/ (1) NUT &1" Ø x 8" ANCHORWASHER @ 60" O.C.OR SIMPSON MAB6 @48" O.C. OR APP'D EQ.6"WALLGALV. ROLLED FLASHING4" CONC. SLAB8"6"2"262x6 STUD WALL W/BATT INSUL.HIGH DENSITY F.G.1/2" SHEATHING4 MIL. POLY V.B.1/2" GYP. BD OVER26EL. 108'-4"T.O. 8" CONC.1ST FLOOREL. 110'-0-1/4"1ST FLOOREL. 107'-8"T.O. 8" CONC.1'-6" 6"SECTION AT CONCRETE STOOPSCALE: 1-1/2" = 1'-0"A-02GarageSTUDYCARPETCOVEREDENTRYCONC.SIDEWALK 77 SF11'-0"10'-0"8'-6"6'-0"4'-0" WIDE RECESSEDSTEP IF MORE THAN ONE RISERCOUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701NOVEMBER 21, 2023Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode12/29/2023jnuetzman 8'-4" 9'-81 4" 1'-634"9'-11 8"T.O. SLABELEV.100'-4"T.O. FTG.ELEV.100'1'-6"6" WINDOW& DOOR TRIMCONCRETE STOOP7'-101 8"WALL PLATEELEV.119'-1-3/8"FASTEN SHEATHING TO HEADER WITH 8d COMMON ORGALVANIZED BOX NAILS IN 3" GRID PATTERN AS SHOWNON ATTACHED DETAILS.FOR BRACED WALL REQUIREMENTSUSE 1/2" OSB SHEATHINGBOTH GARAGE PIERSRETURN BOARD &BATTEN AT BOTHSIDES OF ENTRY12" TRIMT.O. MAINFND. WALLELEV.108'-4"1ST FLRSUBFLOORELEV.110'-0-1/4"WALL PLATEELEV.119'-1-3/8"1ST FLRSUBFLOORELEV.110'-0-1/4"T.O. GARAGESLAB AT BACK WALLELEV.108'-4"6" GARAGEDOOR TRIM4'-0" WIDE RECESSEDSTEP IF MORE THAN ONE RISERWINDOWSWINDOWSADDRESS121212127:12SPECTISBL2481SPECTISBL2481SPECTISBL2481PITCHCHANGE18" OVERHANG AT ALL FRONT ELEVATION GABLES5:127:12COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701NOVEMBER 21, 2023Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode12/29/2023jnuetzman T.O. SLABELEV.100'-4"9'-814"9'-1-1/8"A-2RIGHT ELEVATION - B3SCALE: 1/8" = 1'-0"GAS F.P.VENT8'-0"STEP DOWN TOP OF FOUNDATIONWALL AND FOOTING AS GRADE DICTATESSTEP DOWN TOP OF FOUNDATIONWALL AND FOOTING AS GRADE DICTATESA-2REAR ELEVATION - B1SCALE: 1/8" = 1'-0"A-2LEFT ELEVATION - B2SCALE: 1/8" = 1'-0"A-2ROOF PLAN4SCALE: 1/8" = 1'-0"WALL PLATEELEV.119'-1-3/8"1ST FLRSUBFLOORELEV.110'-0-1/4"T.O. SLABELEV.100'-4"WALL PLATEELEV.119'-1-3/8"1ST FLRSUBFLOORELEV.110'-0-1/4"8:128:1271212:1212:127:1212:127:127127:1212:1212:12712121212:1212:121'-6"1'-6"1'-6"1'-0"COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701NOVEMBER 21, 2023 6'-0" X 6'-11" PATIO14'-0"24'-0"20'-0"8'-0"5'-0"7'-012"9'-5"16'-11"3'-1"2'-4"A(2) 1-3/4" x 9-1/2" LSLA(2) 1-3/4" x 9-1/2" LSL7'-6"(2) 36x60 MULLED4A3T.O. 8" WALL108'-4"8"x20" CONCRETEFOOTING - TYPICALT.O. FOOTINGELEV. 100'-0"Unexcavated4" CONC. SLABLINE OF FRAMINGR & SSTEP TOP OFFOUNDATIONDOWN AS GRADEALLOWSFURN.WATERHEATERMechanical / StorageRoom4" CONC. SLABSUMPBEARING WALLUnfinishedFlex Room4" CONC. SLABFamily RoomCARPET18" FLOOR TRUSSES @ 19.2" O.C.58'-0"13'-2"10'-10"21'-0"13'-0"2'-412"50'-6"28'-6" 8" 22'-0" 10'-1" 4'-0"5'-10"2'-412"13'-4"UP 16R 14'-714"W.I.C.CARPET4'-9"3'-6"HALF WALL (+42")OPEN ABOVE3'-6"13'-0"3'-1014"7'-514" 28 "7'-10"340 SF16'-3" M.O.8'-3" M.O.2" LEDGE3'-934"3'-1014"16'-934"T.O. WALL AT DOOR107'-8"T.O. WALL AT DOOR107'-8"T.O. FOOTINGAT GARAGEOUTSIDE OF FULLBASEMENT DIG104'-4"START SLAB AT TOPOF WALL AT BACK OFGARAGE(2) 1-3/4" X 11-7/8" LSL(2) 2x104" DRAINTILE ATFOOTINGS ON EACHWALL AS MARKEDFLUSH8'-814"4'-734"10'-11"5,000 LB. FOOTINGSTRENGTH MIX32"28"3'-101 2" 18" FLOOR TRUSSES @ 19.2" O.C. 18" FLOOR TRUSSES @ 19.2" O.C.BASEMENT PLANA-31SCALE: 3/16" = 1'-0"A(2) 36x60 MULLED46'-0" 20'-0"7'-6" 8'-0" 18'-6" 4'-0" 26'-0"Bedroom #3CARPETHallCARPETBedroom #2CARPETHallCARPETCDCD107'-8"1A-510'-0" MIN. FTG. STEP 10'-0" MIN. FTG. STEP NO DRAINTILE AT WALKOUT WALL ONLY20x20x12 FOOTINGT.O. 6"CURB109'-0"T.O. FOOTINGAT GARAGEOUTSIDE OF FULLBASEMENT DIG104'-4"FIRE RESISTANT FLOOR SYSTEMOR 1/2" GYPSUM WALL BOARDWITH 80 SQ. FEET UNPROTECTED2A-0Unexcavated4" CONC. SLABSSSROD & SHELF3'-1014"5'-512"ROD & SHELF2'-53 4"(2) 2x10(2) 2x10(2) 2x1032"BathC.T.48 SF (FLR)W.I.C.CARPET30" 30"(2) 2x1028"28"28"SS7'-512"3'-1014"7'-834"9'-0" TALL FOUNDATION WALL6" CURB ON TOP OF FOOTINGSAT INTERIOR BEARING WALLS(TYP). TOP OF CURB FLUSHWITH TOP OF BASEMENT SLAB2x4 INTERIOR WALLS WITH AFINISHED BSMT.2'-0"VOID ALLOW FOR SEWER24" VOID TOROD & SHELFT.O. 2" LEDGE107'-8"2'-412"2'-412"14'-0"14'-0"24" CAB.7'-312"4'-114"3'-514"60x34 FIB. BASE30" 30"42" GAS FIREPLACE9'-0" C.T. WALLSBEVFRIDGE3'-0"TILECARPET3'-0"TILECARPET6'-0"(2) 2x10(3) 2x10(3) 2x6(4) 2x6(2) 1-3/4" x 9-1/2" LSL(2) 2x10 2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGEND514 SFROOM SIZESBEDROOM #2 - CARPETMECHANICALFLEX ROOMSTAIR - CARPETREC ROOM - CARPETBEDROOM #3 - CARPETBATH - C.T.TOTAL240 SF340 SF418 SF68 SF296 SF79 SF2128 SFHALL/CLOSET - CARPET117 SFHALL - CARPET56 SFHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701NOVEMBER 21, 2023UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.FAN 14'-0"6'-0"(3)2X1016'x8' O.H. DOOR8'x8' O.H. DOORGarage4" CONCRETE SLAB PITCHEDTOWARDS OVERHEAD DOORS5/8" TYPE X GYP. BRD.ON ALL COMMON WALLS &CEILINGS.MUD ALL JOINTS(2) 2X10 36x18 FIX (2) 2x1048x18 FIX(2)2x6 BETWEEN48x72 FIXOVER48x18 FIX9'-5"36x72OVER36x18LOWER UNIT FIXED36x66CASEOVER36x18 FIX(2)24x66FIXOVER24x18FIX36" GAS COOKTOPW/ WOOD HOODKitchenWOODRO0F TRUSSES@ 24" O.C.GreatRoomCARPET274 SF. FLR.DiningWOOD11'-2" 10" 2'-512"8' HIGH SRO RO0F TRUSSES @ 24" O.C.FoyerWOODDN 16RHALF WALL (+42")HALF WALL (+42")GIRDER TRUSSMudRoomC.T.6'X8' SLIDEROPEN TOBELOWHALF WALL (+42")BathC.T.33 SF (FLOOR)32"VAN.FAN28"STUDYWOOD30" 36"HALLWAYWOODW.I.C.CarpetLIN.COVEREDENTRYCONC.4'-0" 46'-0" 8'-0" 11'-534"2'-6"6'-01 4" 7'-61 4" 3'-814"3'-10" 1'-9" 18'-53 4"7'-0"7'-0"4'-3" 4'-3"12'-1"1'-534"8'-0"28'-6"22'-0"13'-1114"14'-634"13'-0"21'-0"34'-0"24'-0"13'-0"11'-0"10'-0" 6'-0"5'-6"6'-0"58'-0"11'-214"7'-4"6'-434"8'-7"UP 1R UP 1R 10"7'-0"2'-2"4'-012"2'-6"13'-1"LEDGE 9'-1014"10'-438"8'-105 8"24'-0"20'-0"SCALE: 1/4" = 1'-0"FIRST FLOOR PLAN - BA-413'-6"3'-6"LndryLVP44 SF (FLOOR)3'-412"3'-114"GGBFROM MAIN LEVEL 36X18 FIXED G2-2x62-2x6(2)2X10 BB2- 2 x 6 2-2x616'-0"2'-6"8'-0"2'-6"BBWASH/DRYCD36x18 FIX 36x18 FIX36x18 (2)2X10 (2)2X10 3'-412"4'-114"OPENING36" DRYWALL(2) 2x10(2) 2x10 36X18 FIXED (2) 2x10(2)2X1024x66FIXOVER24x18FIX30x18 FIX(2) 2x6BETWEEN30x72 FIX OVER30x18 AWNING30x18 FIX(2) 2x6BETWEEN30x72 FIX OVER30x18 AWNING6'-6"SLIDE-IN3'-534"96" DRYWALLOPENING TO1'-334"(+96")12'-1-1/8" WALLS12'-1-1/8" WALLS 2'-0"FULL HT.REF.CEILING9'-5"48x66 FIX36x66 SH36x66 SH2-2x62-2x6B13'-3"4'-9"ROD & SHELFR & SGIRDER TRUSS(2) 1-3/4" x 11-7/8" LSL CONT. HEADERPORTAL FRAME26'-0" 12'-1-1/8" TALL WALL WINDOW SILLS MORE THAN 6" ABOVEFINISHED GRADE (SURFACE BELOW) ORLESS THAN 36" FROM FINISHED FLOORSHALL REQUIRE A WINDOW OPENINGCONTROL DEVICE.1/2" SHEATHING - EXT.TYPICAL GARAGE WALL2x4 STUD WALLS @ 16" O.C. W/2x6 STUD WALLS @ 16" O.C. W/ (R=21)FIBERGLASS BATT INSULATION 4 MILPOLY VAPOR BARRIER & 1/2" GYP. BD.TYPICAL EXT. WALLINSIDE AND 1/2" SHEATHING - EXT.PrimaryBedroomCarpet1A-523'-8"A48x24 FIXED 45" VAN.PrimaryBathC.T.93 SF (FLR)FAN3'-4"3'-4"7'-314" 2 8 "30"SSSS36"14" SL14" SL7'-1134"11'-1014"11'-6" 14'-0"14'-0"2'-6"2'-6"14'-0" x 14'-0"Screened PorchTrex Decking72'-6"6:126:12VAULT LINE36"LOCKERS W/ CUBBIESW.I.C.C.T.PantryWOODOPENING36" DRYWALL(+96")12'-0" x 24'-0"DeckTrex Decking12'-0"28" PKT.28" PKT.PANELACCESSATTIC22x301'-0" 4'-0" 5'-0"DWR.C. 5'-0" 3'-8"8'-0"3'-0" 28" PKT.FLOOR DRAINFLOOR DRAIN6'-0" GAS FIREPLACE 42" 6'-0"(2)24x66FIXOVER24x18FIXINSULATE GARAGE COMPLETE28" PKT.32"CONC. STEPS60x34 FIB. BASE9'-0" C.T. WALLS24" 24"WALL4'-6"OVENCOMBOBUILT-INS BUILT-INS 6'-412"6'-114" 72"x36" FREE STANDING TUB3'-1034"2'-4" 4'-734"7'-312"4'-6"4'-114"5'-03 4"1'-1014"8'-7" 45" VAN.18"TOWER4'-0"7'-0"WOOD CARPET 3'-6"19'-8"84x48 C.T. BASEZERO-ENTRYSEE DECK DETAILS FOR PORCH / DECK SPECS11'-11"3.5:123.5:12VAULT LINE3.5:123.5:12VAULT LINE3.5:123.5:12VAULT LINESTACK.25" SINK W/ 32"BASE CABINETW/ HEARTHGARAGE HOSE BIBSPRINKLERROUGH-INRO0F TRUSSES@ 24" O.C.RO0F TRUSSES@ 24" O.C.(2) 2x103-2x65x 5 P S L GIRDER TRUSSGIRDER TRUSS (2) 9-1/2 LSL4-2x63-2x63 - 2 x 6 (2)2X10 GIRDER TRUSS(2) 1-3/4" x 11-7/8" LSL CONT. HEADERCANTILEVERED ROOFRO0F TRUSSES @ 24" O.C.GIRDER TRUSSFINISHED ROOM SIZES2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDSTUDY - WOODMAIN BATH - C.T.STAIRS - CARPETGREAT ROOM - CARPETKIT/DINE/FOYER/HALL - WOOD154 SF51 SF67 SF404 SF621 SFPRIMARY BEDROOM - CARPET256 SFPRIMARY BATH - C.T.140 SFMUD ROOM & W.I.C. - C.T.39 SF94 SFPRIMARY W.I.C. - CARPET44 SFLAUNDRY - LVP19 SFPANTRY - WOODWOOD SF. TOTAL - 876 SF.HEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"E9'-5" OFF LANDINGF5'-0"G10'-0"BE FIELD MEASURED BY TRUSS SUPPLIERHEADERS:TRUSS DESIGN BY MFG. TRUSSES NOTEDWITH DIMENSIONS TO BE VERIFED SHALLALL HEADERS ARE (2) 2x10 TYPICAL UNLESSNOTED OTHERWISE ON PLANS.TRUSSES:GREAT ROOM WINDOWS(2) 2x6COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701NOVEMBER 21, 2023Temper ifwithin 60"of tub floor-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).Verify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.556PFHPFHPFHPFH SCALE: 3/16" = 1'-0"FRAMING / FOOTING PLANDECK12x10 DECK JOISTS @ 16" O.C. DECKING SHOULD BE DOWN 4" FROM THE FIRST FLOOR24'-0" LEDGER BOARD14'-0" LEDGER BOARD8'-0" LEDGER BOARD2x10 JOISTS - SOUTHERN YELLOW PINE .40 TREATED5/4" DECKING3-2x10 BEAMS SOUTHERN YELLOW PINE - .40 TREATED6x6 POSTS PONDEROSA PINE - .60 TREATED(2) 2x10(3) 2x10 (2) 2x10(3) 2x10(3) 2x10(2) 2x10(2) 2x10 4'-4"STAIRS TO GRADE4 STRINGERS SPACED EVEN5'-0"12'-0" 1'-0"24'-0"4'-0"10'-0"14'-0"13'-9"3"6'-9"6'-9"14'-0"3"8'-0"8'-0"11'-9"3'-10"SCALE: 3/16" = 1'-0"PORCH HEADER PLANDECK24'-812"4'-7"4'-812"(2) 11-7/8 LSL(2) 11-7/8 LSL (2)11-7/8 LSL4'-812"4'-7"4'-812"5'-4"5'-2"3'-6"4x4 POST TYP.14'-0" x 14'-0"Screened PorchTrex Decking12'-0" x 24'-0"DeckTrex DeckingT.O. DECKING3'-0" 312"T.O. RAILING312"4"4RAILING DETAILSDECKSCALE: 3/8" = 1'-0"4" SPHERE CANNOT PASSWESTBURY RAILING SYSTEMTOP OF 8" CONC.ELEV. 108'-4"ELEV. 109'-6-1/8"1ST FLOOR1178" 34"BOISE RIM BOARD (EXTERIOR)1-1/8" OSB RIM BOARD(R-20)11-7/8" TJI JOISTS2x10 JOISTSFLASHING W/ DRIP EDGEDTT1Z DECK TENSION TIEDECK LEDGER HANGER4"3LATERAL LOAD CONNECTION DECKSCALE: 3/4" = 1'-0"BOLT THROUGH BLOCKING@ 16" O.C.@ 16" O.C.#12 - STRUCTURAL 4" LEDGER SCREWS@ 16" O.C.DUPONT TYVEK BUILDING PAPEREXTERIOR SHEATHINGICE & WATER SHEILDDUPONT TYVEK BUILDING PAPERICE & WATER SHEILDHOLDER REQUIRED TOANCHOR STRAP OR POSTSLOPE TO OF PIERCONCRETE PIER FOOTING512"POST6x6 DECK SUPPORT60"1'-0"FLARE BOTTOM OF FOOTINGTO A MINIMUM DIAMETER OF 24"CONNECT POST TO FOOTING5POST & PIER DETAILDECKSCALE: 1/2" = 1'-0"& A MINIMUM OF 12" DEEP2'-0"COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701NOVEMBER 21, 2023 A-51SCALE: 1/4" = 1'-0"BUILDING SECTION - ELEV "A"R-49 ROOF INSULATION9TRUSSES @ 24" O.C.PRE-ENGINEERED ROOFRAISED GREAT ROOM ROOFMudRoomW.I.C.MasterBathLaundryMechanical / StorageRoomFoyer9'-81 4"PLATE W/ SILL SEAL INSUL. &3/8" ANCHOR BOLTS @ 6'-0" O.C.8'-4" WALLS - (1) 2x6 TOP PLATE PRESSURE TREATED 2x6 SILLTO BOTTOM OF SIDINGOF 6" FROM GRADEMAINTAIN A MIN. CL.8" x 20" CONC. FTG'S4" CONCRETE SLABTYPICALTYPICAL STAIR CONSTRUCTION NOTES:* 6'-10" MINIMUM HEADROOM* (3) 11-7/8" STAIR STRINGERS W/* 11" TREADS* PROVIDE 36" HIGH HANDRAILS & GUARD RAILS PER CODE.~ MINIMUM TREAD DEPTH 10" - MAX RISE 7-3/4"MINIMUM NOSING 34" MAX. NOSING 1-1/4"2'-115 8" 6'-858"13'-3"9'-17 8"18" FLOOR TRUSSES @ 19.2" O.C.8'-11 2" 1'-63 4" 8'-4"5,000 LB. FOOTINGSTRENGTH MIXHALF WALL (+42")HALF WALL (+42")1ST FLRSUBFLOORELEV.110'-0-1/4"T.O. MAINFND. WALLELEV.108'-4"T.O. FTG.ELEV.100'WALL PLATEELEV.119'-1-3/8"9'-118"2'-0"1'-0"19'-8"WALL PLATE ATGREAT ROOMELEV.121'-7 1/4"LINE OF GREAT ROOM CEILING BEYONDHallFIRE RESISTANT FLOOR SYSTEMOR 1/2" GYPSUM WALL BOARDWITH 80 SQ. FEET UNPROTECTEDA-502-20-23SECTIONSTONELEIGH RAMBLER GARAGE LEFT 3 BEDROOM LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC6276701NOVEMBER 21, 2023 INTERIOR & EXTERIOR 4" DIA. PERFORATED DRAIN TILE PIPED TOSUMP BASKET.8'-4" WALLS - (1) 2x6 TOP PLATE 4" CONCRETE SLAB8" x 20" CONC. FTG'S9'-0"ELEV. 100'-0"TOP OF FOOTINGELEV. 119'-1 3/8"TOP OF PLATETOP OF 8" CONC.ELEV. 109'-0"ELEV. 110'-0 1/4"1ST FLOORMAINTAIN A MIN. CL.OF 6" FROM GRADETO BOTTOM OF SIDING9'-118" 3 4"WATERPROOFING1) COAT EXTERIOR W/ POLYUREA WATER-8" THICK CONC. WALLS2x6 STUD WALLS @16" O.C. W/ (R=21) FIBERGLASS BATTINSULATION, 4 MIL POLYVAPOR BARRIER & 1/2"GYPSUM BOARD INSIDE 1/2" EXTERIOR SHEATHING18" FLOOR TRUSSESBLOCKING AT FOUNDATIONWALLS PARALLEL TO FRAMINGSEE DETAIL S-6BPROOFINGDUCTSPACETYPICAL UNLESS NOTEDOTHERWISEOR 1/2" SAG-RESISTANT5/8" TYPE "X" GYP. BD.R-49 ROOF INSULATIONPRE-ENGINEERED ROOFTRUSSES @ 24" O.C.3/4" OSB FLOOR SHEATHING1'-6" 11 2"5,000 LB. FOOTINGSTRENGTH MIX2) FOAM W/ POLYURETHANE (R-15)6 MIL POLY SLIP SHEET OVERFOAM PRIOR TO BACKFILLAS REQUIRED PER CITYBOISE RIM BOARD1-1/8" OSB RIM BOARD(R-20)8'-4" WALLS - (1) 2x6 TOP PLATE 1/2" ANCHOR BOLTSPLATE W/ SILL SEAL INSUL. &PRESSURE TREATED 2x6 SILLSEAL ALL JOINTS, CRACKS, OR OTHEROPENINGS WITH POLYURETHANE CAULKFOR RADON PROTECTIONFIRE RESISTANT FLOOR SYSTEM1/2" GYPSUM WALL BOARD WITH80 SQUARE FEET UNPROTECTED3" EXTERIOR FOAM INSULATION ATLOOKOUT/WALKOUT SIDE WALLS. 2"FOAM AT FULL BASEMENT & 4' FROSTFOOTINGS.BUILDING SECTION1A-6SCALE: 1/2" = 1'-0"GLUED AND NAILED10'-41 4"RIGID METAL FLASHING INSTALLED BY SIDERPROTECTION TO6" BELOW GRADE1/2" ANCHOR BOLTS@ 6'-0" O.C. (8" EMBED.)SHINGLES OVER 15#15/32" OSB ROOF SHEATHINGBUILDING PAPER(ICE DAM EAVES3) APPLY ABOVE GRADEFOUNDATION COATING2'-6"1'-23 8"A-602-20-2023SECTIONSTONELEIGH RAMBLER GARAGE LEFT 3 BEDROOM LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC6276701NOVEMBER 21, 2023 DescriptionDateRevisionProject Number:Date:S11Sheets: of1Print Name:Signed: License Number:Garrett Brunell52600Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.Youngfield Homes, Inc.22260 Dodd BoulevardLakeville, MN 550445851 Cedar Lake RoadSuite 202St. Louis Park, MN 55416Tel 612-708-3572www.hansongroupmn.comPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.Foster Residence17963 Headwaters DriveLakeville, MNDecember 18, 20233.57712-18-23PARTIAL LOWER LEVEL HOUSE PLANSHOWN FOR LOCATION REFERENCE ONLY1S1REFERENCE PLAN©COPYRIGHT HANSON GROUP, LLC 2023©POST-INSTALLED HOLDOWN OPTION4S1FRAMING DETAILS1FRAMING DETAILGARAGE FRONT PORTAL FRAME3NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.CONCRETEFOUNDATIONBELOWSIMPSON HTT5 HOLDOWNANCHOR AT LOCATIONSSHOWN w/ 12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHORINDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ON EXTERIOR FACE IN ACCORDANCE w/ NOTE 2. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TO BE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)(MIN. LENGTH)THIS SHEET REPRESENTS A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRE RESIDENTIAL STRUCTURE.THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WIND RESISTING ELEMENT THAT IS REQUIRED FOR THE HANSONGROUP'S DESIGN IS SHOWN ON THE STRUCTURAL DRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TO ROOF TRUSSESABOVE, TO TRUSSES/BLOCKING ABOVE, AND TO TRUSSES/BLOCKING BELOW. THESE PANELSARE NOT NECESSARILY REQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUM SHEATHING BOTH FACES WITH EITHER FASTENER OPTION LISTED INNOTE 3, SPACED AT 4" O.C. PROVIDE INCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.EXTERIOR NON-BEARING WALLFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)w/ TRUSSESw/ TRUSSESROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIPNAIL BOTTOM PLATETO RIBBON BRACE /TRUSS w/ (3) 16dNAILS EVERY 16"2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHNAIL EACH TRUSS TOTOP PLATES w/ (3)0.131"Ø x 3" TOENAILSROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO LADDERTRUSS w/ (3) 16dNAILS EVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/0.131"Ø x 3"NAILS @ 6" O.C.w/ TRUSSESw/ TRUSSESINTERIOR WALLPERPENDICULAR TO FRAMINGINTERIOR WALLPARALLEL w/ FRAMING2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN TRUSSESNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH TRUSS TO TOP PLATEw/ (3) 0.131"Ø x 3" TOENAILSPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSS DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.MAIN LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLYREFERENCE PLAN2S1BRACEDWALL LINE(4-FT)(4-FT)(4-FT)(4-FT)BRACEDWALL LINE(2.75-FT)BRACEDWALL LINE(3.8-FT)(5-FT)BRACED WALL LINE BRACED WALL LINE (6-FT)(4-FT)CONSTRUCTPORTAL FRAME ASSHOWN IN 3/S1CONSTRUCTPORTAL FRAME ASSHOWN IN 3/S1, SIM.BRACED WALL LINE(4-FT) (4-FT) (4-FT) (4-FT)(4-FT)(4-FT)BALLOON FRAMEREAR GREAT ROOMWALL TO BOTTOMOF VAULT, BYSUPPLIER(4-FT)BALLOON FRAMESIDE PRIMARYBEDROOM WALL TOBOTTOM OF VAULT,BY SUPPLIER(4-FT)BALLOON FRAMEREAR DINING ROOMWALL TO BOTTOMOF VAULT, BYSUPPLIER(2.66-FT)2'-412"±16'-3"±8'-3"± @ SIM.10'-938"±FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x4/2x6 BEARING STUD & (1) 2x4/2x6FULL HEIGHT STUD EACH END OF HEADERCONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN.312" WIDTH & MIN.1114" DEPTH REQ'D)LOCATE PANEL JOINT WITHIN 2'-0" FROMCENTER OF HEADER HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x4/2x6 BEARING STUDS MIN.(VERIFY w/ SUPPLIER)PROVIDE 2x4/2x6 INFILL WALL ABOVE HEADER AS REQ'DFOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADERNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/(2) ROWS 8d NAILS @ 3" O.C. STAGGERED &TO PLATES / BLOCKING @ 3" O.C.)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.2'-412"±(2) 58" Ø ANCHOR BOLTS (7" MIN. EMBED)w/ 2"x2"x316" PLATE WASHERSFASTEN FRAMING ABOVE ASSHOWN FOR BRACED WALL PANELSLARGE HATCH AREA INDICATES 716" OR THICKERPLYWOOD OR OSB SHEATHING APPLIED TO EXTERIORSIDE OF STUDS w/ STANDARD 6"/12" NAILINGSIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 4/S1 FOR ALTERNATIVE OPTION)SCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM FOR A SINGLE-FAMILY RESIDENCE. CONSTRUCTION ISTO BE IN ACCORDANCE WITH THIS DOCUMENT, STANDARD INDUSTRY PRACTICE, AND THE CODE.NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO CONSTRUCTION DOCUMENTS FOR MORE INFORMATION.2.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICHMEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x6 STUDS SPACED @ 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.3.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. ORTYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)4.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS.5.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIP OR EQUIVALENT AND (4) 0.131"Ø x 3"TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.6.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12) 0.131"Ø x 3" INLAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3" FACE NAILS.7.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).8.TALL WALL FRAMING IS TO BE DESIGNED BY SUPPLIER FOR GRAVITY AND OUT-OF-PLANE WIND LOADING.9.THE COVERED ENTRY, SCREENED PORCH AND DECK ARE CONSIDERED BY THE HANSON GROUP TO BE PRIMARILYOPEN, NON-ESSENTIAL STRUCTURES AND ARE EXCLUDED FROM THE OVERALL MAIN WINDFORCE SYSTEM OF THEHOME. PROVIDE CODE REQUIRED LEDGER TENSION AND POST UPLIFT CONNECTIONS. CONTACT THE HANSON GROUPIF A RIGID DESIGN OF THE SCREENED PORCH IS DESIRED OR REQUIRED.MATERIALSWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLSL STUDS:112" WIDTH - 1.3E OR BETTERLSL BEAMS:134" WIDTH - 1.55E OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLOADSROOF SNOW LOAD: 35 PSFROOF DEAD LOAD: 15 PSFFLOOR LIVE LOAD: 40 PSFFLOOR DEAD LOAD: 15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODE2020 MINNESOTA RESIDENTIAL CODE(5-FT)(4-FT)AT SIM. - (1) 2x4/2x6 BEARING STUD & (2)2x4/2x6 FULL HEIGHT STUDS THIS END OFHEADER(4-FT)(4-FT)(2.75-FT) FIRST FLOORTOTAL3,498 SF2,128 SF--GARAGEBASEMENTFLOOR AREAFINISHED-1,370 SF689 SF758 SFUNFINISHED200 AMP SERVICEWALKOUT BASEMENTGARAGE LEFTSIDEWALK77 SFGARAGE SLABBASEMENT SLABFLATWORK SQUARE FOOTAGE1,998 SF752 SFHIGHVIEW RIDGELOT 2, BLOCK 5 17963 HEADWATERS DRIVEROCKY & KARMYN FOSTERHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"E9'-6"F5'-0"2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDLAKEVILLE, MN 55044G10'-0"2018 BUILDING CODE2020 ENERGY CODEFRAMERS - MAKE SURE THERE IS ICE & WATER SHIELD BEHIND PORCH FRAMERS - 1/2" SHEATHING SHOULD BE FLUSH WITH CONCRETE& DECK LEDGERSCOUNTRY JOE SERIESEXTERIOR FOUNDATION INSULATION9'-0" TALL FOUNDATION WALLS3'-214"6'-312"LINE OFLINE OFFIREPLACESHEETROCK5'-4"FIREPLACE / ENTERTAINMENT CENTERSCALE: 1/4" = 1'-0"1'-5"1'-5"TILELINE OF FRAMING3'-134"3'-134"6'-0"6'-0"3'-6" 1'-5"6'-312"3'-412"3'-112"6"5'-834"5'-834"12'-118"10'-0"61 2"112"0" DEEP18-1/2" DEEP LEDGE17" DEEP17" DEEP0" DEEP2'-0"1'-118"24" DEEP SOFFITLINE OF SOFFIT2'-0"1'-612"LINE RAISED LEDGESOFFITLINE OFLEDGE0" DEEP0" DEEP24" DEEP18-1/2" DEEP2'-0"A-01BOLT W/ (1) NUT &1" Ø x 8" ANCHORWASHER @ 60" O.C.OR SIMPSON MAB6 @48" O.C. OR APP'D EQ.6"WALLGALV. ROLLED FLASHING4" CONC. SLAB8"6"2"262x6 STUD WALL W/BATT INSUL.HIGH DENSITY F.G.1/2" SHEATHING4 MIL. POLY V.B.1/2" GYP. BD OVER26EL. 108'-4"T.O. 8" CONC.1ST FLOOREL. 110'-0-1/4"1ST FLOOREL. 107'-8"T.O. 8" CONC.1'-6" 6"SECTION AT CONCRETE STOOPSCALE: 1-1/2" = 1'-0"A-02GarageSTUDYCARPETCOVEREDENTRYCONC.SIDEWALK 77 SF11'-0"10'-0"8'-6"6'-0"4'-0" WIDE RECESSEDSTEP IF MORE THAN ONE RISERCOUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701NOVEMBER 21, 2023 8'-4" 9'-81 4" 1'-634"9'-11 8"T.O. SLABELEV.100'-4"T.O. FTG.ELEV.100'1'-0"6" WINDOW& DOOR TRIM3'-0"CONCRETE STOOP7'-101 8"WALL PLATEELEV.119'-1-3/8"FASTEN SHEATHING TO HEADER WITH 8d COMMON ORGALVANIZED BOX NAILS IN 3" GRID PATTERN AS SHOWNON ATTACHED DETAILS.FOR BRACED WALL REQUIREMENTSUSE 1/2" OSB SHEATHINGBOTH GARAGE PIERSRETURN BOARD &BATTEN AT BOTHSIDES OF ENTRY12" TRIMT.O. MAINFND. WALLELEV.108'-4"1ST FLRSUBFLOORELEV.110'-0-1/4"WALL PLATEELEV.119'-1-3/8"1ST FLRSUBFLOORELEV.110'-0-1/4"T.O. GARAGESLAB AT BACK WALLELEV.108'-4"6" GARAGEDOOR TRIM4'-0" WIDE RECESSEDSTEP IF MORE THAN ONE RISERWINDOWSWINDOWSADDRESS121212127:12SPECTISBL2481SPECTISBL2481SPECTISBL2481COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701NOVEMBER 21, 2023 T.O. SLABELEV.100'-4"9'-814"9'-1-1/8"A-2RIGHT ELEVATION - B3SCALE: 1/8" = 1'-0"GAS F.P.VENT8'-0"STEP DOWN TOP OF FOUNDATIONWALL AND FOOTING AS GRADE DICTATESSTEP DOWN TOP OF FOUNDATIONWALL AND FOOTING AS GRADE DICTATESA-2REAR ELEVATION - B1SCALE: 1/8" = 1'-0"A-2LEFT ELEVATION - B2SCALE: 1/8" = 1'-0"A-2ROOF PLAN4SCALE: 1/8" = 1'-0"WALL PLATEELEV.119'-1-3/8"1ST FLRSUBFLOORELEV.110'-0-1/4"T.O. SLABELEV.100'-4"WALL PLATEELEV.119'-1-3/8"1ST FLRSUBFLOORELEV.110'-0-1/4"8:128:1271212:1212:127:1212:127:127127:1212:1212:12712121212:1212:12COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701NOVEMBER 21, 2023 6'-0" X 6'-11" PATIO14'-0"24'-0"20'-0"8'-0"5'-0"7'-012"9'-5"16'-11"3'-1"2'-4"A(2) 2x10(2) 1-3/4" x 9-1/2" LSLA(2) 1-3/4" x 9-1/2" LSL7'-6"(2) 36x60 MULLED4A3T.O. 8" WALL108'-4"8"x20" CONCRETEFOOTING - TYPICALT.O. FOOTINGELEV. 100'-0"Unexcavated4" CONC. SLABLINE OF FRAMINGR & SSTEP TOP OFFOUNDATIONDOWN AS GRADEALLOWSFURN.WATERHEATERMechanical / StorageRoom4" CONC. SLABSUMPBEARING WALLUnfinishedFlex Room4" CONC. SLABFamily RoomCARPET18" FLOOR TRUSSES @ 19.2" O.C.58'-0"13'-2"10'-10"21'-0"13'-0"2'-412"50'-6"28'-6" 8" 22'-0" 10'-1"3'-2"1'-0" 4'-0"5'-10"2'-412"13'-4"UP 16R 14'-714"W.I.C.CARPET4'-9"3'-6"HALF WALL (+42")OPEN ABOVE3'-6"13'-0"3'-10"7'-514" 28 "7'-10"340 SF16'-3" M.O.8'-3" M.O.2" LEDGE3'-934"3'-1014"16'-934"T.O. WALL AT DOOR107'-8"T.O. WALL AT DOOR107'-8"T.O. FOOTINGAT GARAGEOUTSIDE OF FULLBASEMENT DIG104'-4"START SLAB AT TOPOF WALL AT BACK OFGARAGE(2) 1-3/4" X 11-7/8" LSL(2) 2x104" DRAINTILE ATFOOTINGS ON EACHWALL AS MARKEDFLUSH8'-814"4'-734"10'-11"5,000 LB. FOOTINGSTRENGTH MIX32"28"3'-101 2" 18" FLOOR TRUSSES @ 19.2" O.C. 18" FLOOR TRUSSES @ 19.2" O.C.BASEMENT PLANA-31SCALE: 3/16" = 1'-0"A(2) 36x60 MULLED46'-0" 20'-0"7'-6" 8'-0" 18'-6" 4'-0" 26'-0"Bedroom #3CARPETHallCARPETBedroom #2CARPETHallCARPETCDCD107'-8"1A-510'-0" MIN. FTG. STEP 10'-0" MIN. FTG. STEP NO DRAINTILE AT WALKOUT WALL ONLY20x20x12 FOOTINGT.O. 6"CURB109'-0"T.O. FOOTINGAT GARAGEOUTSIDE OF FULLBASEMENT DIG104'-4"FIRE RESISTANT FLOOR SYSTEMOR 1/2" GYPSUM WALL BOARDWITH 80 SQ. FEET UNPROTECTED2A-0Unexcavated4" CONC. SLABSSSROD & SHELF3'-1014"5'-512"ROD & SHELF2'-53 4"(2) 11-7/8" LSL(2) 2x10(2) 2x1032"BathC.T.48 SF (FLR)W.I.C.CARPET30" 30"(2) 2x1028"28"28"SS7'-512"3'-1014"7'-834"9'-0" TALL FOUNDATION WALL6" CURB ON TOP OF FOOTINGSAT INTERIOR BEARING WALLS(TYP). TOP OF CURB FLUSHWITH TOP OF BASEMENT SLAB2x4 INTERIOR WALLS WITH AFINISHED BSMT.2'-0"VOID ALLOW FOR SEWER24" VOID TOROD & SHELFT.O. 2" LEDGE107'-8"2'-412"2'-412"14'-0"14'-0"24" CAB.8'-6"3'-6"2'-10"60x34 FIB. BASE30" 30"72" GAS FIREPLACE8'-0" C.T. WALLSBEVFRIDGE2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGEND514 SFROOM SIZESBEDROOM #2 - CARPETMECHANICALFLEX ROOMSTAIR - CARPETREC ROOM - CARPETBEDROOM #3 - CARPETBATH - C.T.TOTAL240 SF340 SF418 SF68 SF296 SF79 SF2128 SFHALL/CLOSET - CARPET117 SFHALL - CARPET56 SFHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701NOVEMBER 21, 2023= Loaded for Deck Load2-2x10 Trtd.*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***B1B2||[||[[[[||[||OK2 - 2 x 10OKOKOK3 - 2 x 102 - 2 x 102 - 2 x 103-2x10 Trtd.2-2x10 Trtd.OK2 - 9-1/2" LSL2 - Trimmers2-2x10OK4-2x63-2x6X3-2x10 Trtd.LUS210-3Z 14'-0"6'-0"(3)2X1016'x8' O.H. DOOR8'x8' O.H. DOORGarage4" CONCRETE SLAB PITCHEDTOWARDS OVERHEAD DOORS5/8" TYPE X GYP. BRD.ON ALL COMMON WALLS &CEILINGS.MUD ALL JOINTSRO0F TRUSSES @ 24" O.C. (2) 2X10 36x18 FIX (3) 2x1048x18 FIX(2)2x6 BETWEEN48x72 FIXOVER48x18 FIX9'-5"36x72OVER36x18LOWER UNIT FIXED36x66CASEOVER36x18 FIX(2)24x66FIXOVER24x18FIX36" GAS COOKTOPW/ WOOD HOODKitchenWOODRO0F TRUSSES @ 24" O.C.GreatRoomCARPET274 SF. FLR.DiningWOOD11'-2" 10" 2'-512"8' HIGH SRO RO0F TRUSSES @ 24" O.C.FoyerWOODDN 16RHALF WALL (+42")HALF WALL (+42")GIRDER TRUSSMudRoomC.T.6'X8' SLIDEROPEN TOBELOWHALF WALL (+42")BathC.T.33 SF (FLOOR)32"VAN.FAN28"STUDYWOOD30" 36"HALLWAYWOODW.I.C.CarpetLIN.COVEREDENTRYCONC.4'-0" 46'-0" 8'-0" 11'-534"2'-6"6'-01 4" 7'-61 4" 3'-814"3'-10" 1'-9" 18'-53 4"7'-0"7'-0"4'-3" 4'-3"11'-10"1'-534"8'-0"28'-6"22'-0"13'-1114"14'-634"13'-0"21'-0"34'-0"24'-0"10"2"13'-0"11'-0"2'-8"10'-0" 6'-0"5'-6"6'-0"58'-0"11'-214"7'-4"6'-434"8'-7"UP 1R UP 1R 10"7'-0"2'-2"4'-012"2'-6"13'-1"LEDGE 9'-1014"10'-438"8'-105 8"24'-0"20'-0"SCALE: 1/4" = 1'-0"FIRST FLOOR PLAN - BA-413'-6"3'-6"LndryLVP44 SF (FLOOR)3'-412"3'-114"GGBFROM MAIN LEVEL 36X18 FIXED G2-2x62-2x6(2)2X10 BB2- 2 x 6 2-2x616'-0"2'-6"8'-0"2'-6"BBDRY.WASHCD36x18 FIX 36x18 FIX36x18 (2)2X10(2)2X10 3'-412"4'-114"OPENING36" DRYWALL(3)2x10(2) 2x10(2) 2x10 36X18 FIXED (2) 2x10(2)2X1024x66FIXOVER24x18FIX30x18 FIX(2) 2x6BETWEEN30x72 FIX OVER30x18 AWNING30x18 FIX(2) 2x6BETWEEN30x72 FIX OVER30x18 AWNING4'-6"SLIDE-IN3'-534"96" DRYWALLOPENING TO1'-334"(+96")12'-1-1/8" WALLS12'-1-1/8" WALLS 2'-0"FULL HT.REF.CEILING9'-5"48x66 FIX36x66 SH36x66 SH2-2x62-2x6B13'-3"4'-9"ROD & SHELFR & SGIRDER TRUSS(2) 1-3/4" x 11-7/8" LSL CONT. HEADERPORTAL FRAME26'-0" 12'-1-1/8" TALL WALL WINDOW SILLS MORE THAN 6" ABOVEFINISHED GRADE (SURFACE BELOW) ORLESS THAN 36" FROM FINISHED FLOORSHALL REQUIRE A WINDOW OPENINGCONTROL DEVICE.1/2" SHEATHING - EXT.TYPICAL GARAGE WALL2x4 STUD WALLS @ 16" O.C. W/2x6 STUD WALLS @ 16" O.C. W/ (R=21)FIBERGLASS BATT INSULATION 4 MILPOLY VAPOR BARRIER & 1/2" GYP. BD.TYPICAL EXT. WALLINSIDE AND 1/2" SHEATHING - EXT.PrimaryBedroomCarpet1A-523'-8"A48x24 FIXED 45" VAN.PrimaryBathC.T.93 SF (FLR)FAN3'-4"3'-4"7'-314" 2 8 "12'-1-1/8" WALLS30"SSSS36"14" SL14" SL7'-1134"11'-1014"11'-6" 14'-0"14'-0"2'-6"2'-6"14'-0" x 14'-0"Screened PorchTrex Decking72'-6"6:126:12VAULT LINE36"LOCKERS W/ CUBBIESW.I.C.C.T.PantryWOODOPENING36" DRYWALL(+96")12'-0" x 24'-0"DeckTrex Decking12'-0"28" PKT.28" PKT.PANELACCESSATTIC22x301'-0" 4'-0" 5'-0"DWR.C. 5'-0" 3'-8"8'-0"3'-0" 28" PKT.FLOOR DRAINFLOOR DRAIN25" SINK W/ 32"BASE CABINET6'-0" GAS FIREPLACE STANDARD 6'-0"(2)24x66FIXOVER24x18FIXINSULATE GARAGE COMPLETE28" PKT.32"CONC. STEPS60x34 FIB. BASE8'-0" C.T. WALLS24" 24"WALL4'-6"OVENCOMBOBUILT-INS BUILT-INS 6'-412"6'-114" 72"x36" FREE STANDING TUB3'-1034"2'-4" 4'-734"7'-312"4'-6"4'-114"5'-03 4"1'-1014"8'-7" 45" VAN.18"TOWER4'-0"7'-0"FANWOOD CARPET 6'-0"17'-2"84x48 C.T. BASEZERO-ENTRYSEE DECK DETAILS FOR PORCH / DECK SPECS12'-2"3.5:123.5:12VAULT LINE3.5:123.5:12VAULT LINE3.5:123.5:12VAULT LINEFINISHED ROOM SIZES2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDSTUDY - WOODMAIN BATH - C.T.STAIRS - CARPETGREAT ROOM - CARPETKIT/DINE/FOYER/HALL - WOOD154 SF51 SF67 SF404 SF621 SFPRIMARY BEDROOM - CARPET256 SFPRIMARY BATH - C.T.140 SFMUD ROOM & W.I.C. - C.T.39 SF94 SFPRIMARY W.I.C. - CARPET44 SFLAUNDRY - LVP19 SFPANTRY - WOODWOOD SF. TOTAL - 876 SF.HEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"E9'-5" OFF LANDINGF5'-0"G10'-0"BE FIELD MEASURED BY TRUSS SUPPLIERHEADERS:TRUSS DESIGN BY MFG. TRUSSES NOTEDWITH DIMENSIONS TO BE VERIFED SHALLALL HEADERS ARE (2) 2x10 TYPICAL UNLESSNOTED OTHERWISE ON PLANS.TRUSSES:GREAT ROOM WINDOWS(2) 2x6COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701NOVEMBER 21, 2023*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***MFG Roof Trussesby OthersMFG Roof Trusses by Others Girder TrussHip Girder TrussMFG Roof Trussesby OthersRoof CantileverGirder TrussGirder TrussMFG Roof Trussesby Others2 - 2 x 10OKOKOK2 - 11-7/8" LSL2 - 2 x 10OKOKOKOKOKOKOK2 - 1 3/4" x 11 7/8" LSL2 - 2 x 102 - 1 3/4" x 9 1/2" LSL||[||[[[[||[||5x5 PSL3-2x64-2x63-2x63-2x62 - 11-7/8" LSL2 - 11-7/8" LSL SCALE: 3/16" = 1'-0"FRAMING / FOOTING PLANDECK12x10 DECK JOISTS @ 16" O.C. DECKING SHOULD BE DOWN 4" FROM THE FIRST FLOOR24'-0" LEDGER BOARD14'-0" LEDGER BOARD8'-0" LEDGER BOARD2x10 JOISTS - SOUTHERN YELLOW PINE .40 TREATED5/4" DECKING3-2x10 BEAMS SOUTHERN YELLOW PINE - .40 TREATED6x6 POSTS PONDEROSA PINE - .60 TREATED(2) 2x10(2) 2x10 (3) 2x10(3) 2x10(3) 2x10(2) 2x10(2) 2x10 4'-4"STAIRS TO GRADE4 STRINGERS SPACED EVEN5'-0"12'-0" 1'-0"24'-0"4'-0"10'-0"14'-0"13'-9"3"6'-9"6'-9"14'-0"3"8'-0"8'-0"11'-9"3'-10"SCALE: 3/16" = 1'-0"PORCH HEADER PLANDECK24'-812"4'-7"4'-812"(2) 9-1/2 LSL(2) 9-1/2 LSL (2) 9-1/2 LSL4'-812"4'-7"4'-812"5'-4"5'-2"3'-6"4x4 POST TYP.14'-0" x 14'-0"Screened PorchTrex Decking12'-0" x 24'-0"DeckTrex DeckingT.O. DECKING3'-0" 312"T.O. RAILING312"4"4RAILING DETAILSDECKSCALE: 3/8" = 1'-0"4" SPHERE CANNOT PASSWESTBURY RAILING SYSTEMTOP OF 8" CONC.ELEV. 108'-4"ELEV. 109'-6-1/8"1ST FLOOR1178" 34"BOISE RIM BOARD (EXTERIOR)1-1/8" OSB RIM BOARD(R-20)11-7/8" TJI JOISTS2x10 JOISTSFLASHING W/ DRIP EDGEDTT1Z DECK TENSION TIEDECK LEDGER HANGER4"3LATERAL LOAD CONNECTION DECKSCALE: 3/4" = 1'-0"BOLT THROUGH BLOCKING@ 16" O.C.@ 16" O.C.#12 - STRUCTURAL 4" LEDGER SCREWS@ 16" O.C.DUPONT TYVEK BUILDING PAPEREXTERIOR SHEATHINGICE & WATER SHEILDDUPONT TYVEK BUILDING PAPERICE & WATER SHEILDHOLDER REQUIRED TOANCHOR STRAP OR POSTSLOPE TO OF PIERCONCRETE PIER FOOTING512"POST6x6 DECK SUPPORT60"1'-0"FLARE BOTTOM OF FOOTINGTO A MINIMUM DIAMETER OF 24"CONNECT POST TO FOOTING5POST & PIER DETAILDECKSCALE: 1/2" = 1'-0"& A MINIMUM OF 12" DEEP2'-0"COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701NOVEMBER 21, 2023 A-51SCALE: 1/4" = 1'-0"BUILDING SECTION - ELEV "A"R-49 ROOF INSULATION9TRUSSES @ 24" O.C.PRE-ENGINEERED ROOFRAISED GREAT ROOM ROOFMudRoomW.I.C.MasterBathLaundryMechanical / StorageRoomFoyer9'-81 4"PLATE W/ SILL SEAL INSUL. &3/8" ANCHOR BOLTS @ 6'-0" O.C.8'-4" WALLS - (1) 2x6 TOP PLATE PRESSURE TREATED 2x6 SILLTO BOTTOM OF SIDINGOF 6" FROM GRADEMAINTAIN A MIN. CL.8" x 20" CONC. FTG'S4" CONCRETE SLABTYPICALTYPICAL STAIR CONSTRUCTION NOTES:* 6'-10" MINIMUM HEADROOM* (3) 11-7/8" STAIR STRINGERS W/* 11" TREADS* PROVIDE 36" HIGH HANDRAILS & GUARD RAILS PER CODE.~ MINIMUM TREAD DEPTH 10" - MAX RISE 7-3/4"MINIMUM NOSING 34" MAX. NOSING 1-1/4"2'-115 8" 6'-858"13'-3"9'-17 8"18" FLOOR TRUSSES @ 19.2" O.C.8'-11 2" 1'-63 4" 8'-4"5,000 LB. FOOTINGSTRENGTH MIXHALF WALL (+42")HALF WALL (+42")1ST FLRSUBFLOORELEV.110'-0-1/4"T.O. MAINFND. WALLELEV.108'-4"T.O. FTG.ELEV.100'WALL PLATEELEV.119'-1-3/8"9'-118"2'-0"1'-0"19'-8"WALL PLATE ATGREAT ROOMELEV.121'-7 1/4"LINE OF GREAT ROOM CEILING BEYONDHallFIRE RESISTANT FLOOR SYSTEMOR 1/2" GYPSUM WALL BOARDWITH 80 SQ. FEET UNPROTECTEDA-502-20-23SECTIONSTONELEIGH RAMBLER GARAGE LEFT 3 BEDROOM LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC6276701NOVEMBER 21, 2023 INTERIOR & EXTERIOR 4" DIA. PERFORATED DRAIN TILE PIPED TOSUMP BASKET.8'-4" WALLS - (1) 2x6 TOP PLATE 4" CONCRETE SLAB8" x 20" CONC. FTG'S9'-0"ELEV. 100'-0"TOP OF FOOTINGELEV. 119'-1 3/8"TOP OF PLATETOP OF 8" CONC.ELEV. 109'-0"ELEV. 110'-0 1/4"1ST FLOORMAINTAIN A MIN. CL.OF 6" FROM GRADETO BOTTOM OF SIDING9'-118" 3 4"WATERPROOFING1) COAT EXTERIOR W/ POLYUREA WATER-8" THICK CONC. WALLS2x6 STUD WALLS @16" O.C. W/ (R=21) FIBERGLASS BATTINSULATION, 4 MIL POLYVAPOR BARRIER & 1/2"GYPSUM BOARD INSIDE 1/2" EXTERIOR SHEATHING18" FLOOR TRUSSESBLOCKING AT FOUNDATIONWALLS PARALLEL TO FRAMINGSEE DETAIL S-6BPROOFINGDUCTSPACETYPICAL UNLESS NOTEDOTHERWISEOR 1/2" SAG-RESISTANT5/8" TYPE "X" GYP. BD.R-49 ROOF INSULATIONPRE-ENGINEERED ROOFTRUSSES @ 24" O.C.3/4" OSB FLOOR SHEATHING1'-6" 11 2"5,000 LB. FOOTINGSTRENGTH MIX2) FOAM W/ POLYURETHANE (R-15)6 MIL POLY SLIP SHEET OVERFOAM PRIOR TO BACKFILLAS REQUIRED PER CITYBOISE RIM BOARD1-1/8" OSB RIM BOARD(R-20)8'-4" WALLS - (1) 2x6 TOP PLATE 1/2" ANCHOR BOLTSPLATE W/ SILL SEAL INSUL. &PRESSURE TREATED 2x6 SILLSEAL ALL JOINTS, CRACKS, OR OTHEROPENINGS WITH POLYURETHANE CAULKFOR RADON PROTECTIONFIRE RESISTANT FLOOR SYSTEM1/2" GYPSUM WALL BOARD WITH80 SQUARE FEET UNPROTECTED3" EXTERIOR FOAM INSULATION ATLOOKOUT/WALKOUT SIDE WALLS. 2"FOAM AT FULL BASEMENT & 4' FROSTFOOTINGS.BUILDING SECTION1A-6SCALE: 1/2" = 1'-0"GLUED AND NAILED10'-41 4"RIGID METAL FLASHING INSTALLED BY SIDERPROTECTION TO6" BELOW GRADE1/2" ANCHOR BOLTS@ 6'-0" O.C. (8" EMBED.)SHINGLES OVER 15#15/32" OSB ROOF SHEATHINGBUILDING PAPER(ICE DAM EAVES3) APPLY ABOVE GRADEFOUNDATION COATING2'-6"1'-23 8"A-602-20-2023SECTIONSTONELEIGH RAMBLER GARAGE LEFT 3 BEDROOM LAKEVILLE, MN 55044 22260 DODD BLVD. Phone (952) 469-4066 YOUNGFIELD HOMES COUNTRY JOE HOMES LIC. # BC6276701NOVEMBER 21, 2023 Print Name: Signed: Nick Hanson I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. License Number:1-1-23 46665Date: SCOPE OF DRAWINGS: THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED AND CERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESE DRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P. CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANT TO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR. THESE DRAWINGS EXPIRE ON DECEMBER 31, 2023. 2023 FOUNDATION GUIDE: DRAWING INDEX: SCOPE, INDEX, & CERTIFICATION S0 USE GUIDELINES AND MATERIALS S1 GENERAL NOTES S2 STEP FOOTING DETAIL S3 WALKOUT WALL DETAIL S4 LOOKOUT/KNEE WALL DETAIL S5 EXTERIOR LOW GRADE FOUNDATION DETAIL S6 BASEMENT WALL DETAIL S7 BASEMENT WALL VERTICAL REINFORCING TABLE S8 BRICK LEDGE DETAILS S9 FLOOR MEMBER BEARING DETAIL AND CONNECTION TABLE S10 BASEMENT WALL ANCHOR SPACING TABLE S11 NON-BEARING WALL JOIST BLOCKING DETAIL S12 NON-BEARING WALL TRUSS BLOCKING DETAIL S13 WINDOW WELL DETAIL S14 STEPPING DOWN WALL WITH GRADE S15 COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 150 3.001 January 1, 2023 S0 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS SCOPE, INDEX, & CERTIFICATION Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 DRAWING USE GUIDELINES AND LIMITATIONS THE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THIS PACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE. THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THE PROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS. THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT IN ACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEW AND INSPECTIONS. LIMITATIONS 1. BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOP OF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT). 2. STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT. 3. OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITE SPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED. 4. STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST OR STRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED. 5. EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS. 6. ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURAL ENGINEERING DOCUMENTS. COLD WEATHER GUIDELINES: 1. THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILL ADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONAL CEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED AT TEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F. 2. DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHEN POSSIBLE. 3. DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS IS RECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR IN CONTACT WITH FROZEN MATERIALS. 4. REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE. 5. BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLS WHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALL WHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F. **THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHER REQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE. MATERIALS CONCRETE WALLS: F'c = 3000 PSI @ 28 DAYS MIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIER CONCRETE FOOTINGS: F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDES A WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE. AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX. REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40 #5+ BARS - ASTM A615 GRADE 60 TREATED SILL PLATE: SYP GRADE #2 OR BETTER ALLOWABLE SOIL BEARING PRESSURE 1,500 PSF MINIMUM EQUIVALENT REBAR TABLE FOR BUNDLED HORIZONTAL BARS (2)#4 = (1)#6 (3)#4 = (2)#5 (3)#5 = (2)#6 COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 151 3.001 January 1, 2023 S1 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS DRAWING LIMITATIONS & MATERIALS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane NorthSuite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 GENERAL NOTES 1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVE STRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLY SUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESS ADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 2. STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS. 3. 1 12" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT AND FROST WALLS. 4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIP FOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE. 5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS. 6. SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEET UNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED. 7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, AND INSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTED OTHERWISE. 8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALL THICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS. 9. REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2" OFCENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BAR DIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET. 10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS. HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVER IS ACHIEVED ON ALL SIDES. 11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS. 12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN. VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS. 13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINOR FORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS. 14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONS ARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALL CORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS IN LENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELS MAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHT FOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOAD TRANSFER OVER A SILL PLATE OVERHANG CONDITION. 15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1. 16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. 17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS. 18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL AND DIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICAL REINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED, BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDING IS ACHIEVED. 19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING. MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS. 20.THESE DRAWINGS ARE INTENDED TO BE A LIMITED COMPONENT DESIGN TO RESIST LATERAL SOIL PRESSURES FOR SINGLE FAMILY RESIDENCES. VERTICAL LOADS AND FOOTING DESIGNS ARE TO BE THE RESPONSIBILITY OF THE BUILDING DESIGNER. NO SUPPLEMENTAL ENGINEERING OR COMPONENT DESIGN FOR THE FOUNDATION SYSTEM SHALL BE INCLUDED WITH THIS PACKET WITHOUT THE PRIOR REVIEW AND CONSENT OF THE HANSON GROUP. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 152 3.001 January 1, 2023 S2 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS GENERAL NOTES Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 2 1 $ Q Z 5 J C M Q R G G / 0 (2) #4 HORIZONTAL BARS BOTH TOP & BOTTOM EXTENDED AT LEAST 24" BEYOND EACH END OF STEP STABLE BANK HIGH FOOTING MAY BE EXTENDED PROVIDED BARS ARE PLACED AS SHOWN HORIZ. BARS TOP & BOTTOM 6" MIN THICK CONCRETE FOUNDATION, SEE OTHER DETAILS FOR MORE INFO OPTIONAL CONTROL JOINT AT EACH END OF STEP 72" MAX SPAN EQ.EQ.24" MINDETAIL B 3" MIN TYPCONCRETE STRIP FOOTING 11B DETAIL A 36" MIN STEP 2 x STEP STEPNOTE: DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEP LOCATIONS SHOWN REAR FROST WALL LOOKOUT WALL FULL HEIGHT WALL GARAGE FROST WALL ELEVATION SHOWN FOR REPRESENTATION PURPOSES ONLY -MAY NOT APPLYELEVATION STEP SPACING REQUIREMENTS A TYP. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 153 3.001 January 1, 2023 S3 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS STEP FOOTING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN. WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION OPTIONAL STEM WALL MINIMUM THICKNESS TO MATCH SILL PLATE SILL PLATE TO MATCH FRAME WALL ABOVE 16" MAX FOR 4" THICK STEM 24" MAX. FOR 6" THICK STEM SLAB-ON-GRADE BY OTHERS (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL 6" MIN. C.I.P. CONCRETE FOUNDATION WALL UNREINFORCED CONCRETE STRIP FOOTING SEE S7 #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) DOWELS ARE NOT REQUIRED IF BACKFILL IS PLACED EQUALLY ON BOTH SIDES IN LIFTS NOT TO EXCEED 24"-ALTERNATE EACH SIDE COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 154 3.001 January 1, 2023 S4 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS WALKOUT WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN.3'-0" MAX GRADE HEIGHTABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN. EMBED) CENTERED IN WALL @ 48" O.C. (SAND SOIL) OR 36" O.C. (SANDY-CLAY SOIL) OR 24" O.C. (CLAY SOIL) DOWELS MUST BE WET SET OR DRILLED AND EPOXY GROUTED 6" MIN. THICK C.I.P. CONCRETE FOUNDATION WALL SLOPE GRADE AWAY FROM FOUNDATION 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS (1) #4 x CONT HORIZONTAL BAR AT TOP OF WALL FRAMING & SILL PLATE BY OTHERS SLAB-ON-GRADE BY OTHERS UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (18" MIN WIDTH FOR CLAY BACKFILL OR 16" MIN WIDTH IF 2'-6" MAX UNBALANCED BACKFILL) COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 155 3.001 January 1, 2023 S5 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS LOOKOUT/KNEE WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6'-0" MAXWOOD FRAMING ABOVE BY OTHERS 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION AT A GRADUAL 2% SLOPE PER GENERAL NOTE 6 SILL PLATE TO MATCH FRAME WALL ABOVE #4 x CONTINUOUS HORIZONTAL BARS @ 24" O.C. TYP. OPTIONAL 2" RIGID INSULATION ON INSIDE FACE AND UNDER SLAB-ON-GRADE FOR 24" MIN. UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (DROP FOR FROST AS REQUIRED PER SITE DESIGN) #4x2'-0" DOWELS @ 48" O.C. MAX (5" MIN. EMBED) (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL OPTIONAL SLAB LEDGE CONCRETE SLAB-ON-GRADE 8" MIN. C.I.P. CONCRETE FOUNDATION WALL #4 x 5'-0" HOOKS @ 24" O.C. EMBEDDED IN FOUNDATION WALL & CAST INTO SLAB (MAY REDUCE 2'-0" LEG LENGTH & DRILL IN & EPOXY 8" MIN. INTO FOUNDATION WALL) 3'-0"NO HOOKS @ 3'-0" OR LESSGRANULAR MATERIAL (SAND) DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0" #5 VERTICAL BARS @ 24" O.C. CENTERED IN WALL TO AID IN THE REDUCTION OF CRACKING AND BACKFILLING ISSUES PRIOR TO TOP OF WALL PINNING CONTRACTOR IS TO PROVIDE TEMPORARY TOP OF WALL BRACING UNTIL GARAGE SLAB-ON-GRADE IS IN PLACE (HOOKS INTO GARAGE SLAB PROVIDE REQUIRED TOP OF WALL LATERAL SUPPORT)2'-0" COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 156 3.001 January 1, 2023 S6 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS UNBALANCED FOUNDATION DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN. CLEAR HEIGHTBACKFILL HEIGHT112" CLEAR UNREINFORCED CONCRETE STRIP FOOTING PER CODE OR BY BUILDING DESIGNER, AS AN ALTERNATIVE GUIDE USE TABLE SHOWN BELOW 8" MIN. C.I.P. CONCRETE FOUNDATION WALL-SEE REBAR TABLE S8 FOR VERTICAL REBAR ANCHOR BOLTS SEE WALL ANCHOR INFO ON S11 FLOOR TO SILL CONNECTION SEE S10 WOOD FLOOR SYSTEM BY OTHERS SLOPE GRADE AWAY FROM FOUNDATION 2x6 MIN SILL PLATE CLEAR HEIGHT OF 8'-0" OR LESS (2)#4xCONT. HORIZONTAL BARS CLEAR HEIGHT OF 8'-0" OR MORE (3)#4xCONT. HORIZONTAL BARS CONCRETE SLAB-ON-GRADE PLACED TIGHT TO FOUNDATION WALL #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) GENERAL STRIP FOOTING SIZE GUIDE SOIL ONE-STORY STRUCTURE TWO-STORY STRUCTURE 2000 PSF 16" WIDE x 8" THICK 20" WIDE x 8" THICK 1500 PSF 20" WIDE x 8" THICK 26" WIDE x 8" THICK THIS TABLE IS A GENERAL FOOTING SIZE GUIDE FOR TRIBUTARY UNIFORM LOADING ONLY BASED ON MAXIMUM 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS AND IS TO BE VERIFIED BY HOME DESIGNER. FURTHER CONSIDERATION IS TO BE TAKEN BY HOME DESIGNER FOR VENEER WEIGHT, WALL THICKNESSES OVER 10", AND FLOOR AND ROOF DEAD LOADS OVER 15 PSF. CONCENTRATED LOADS FROM GIRDER TRUSSES, BEAMS, HEADERS, ETC. ARE TO BE ACCOUNTED FOR AND SIZED INDEPENDENTLY OF THIS GUIDE BY OTHERS. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 157 3.001 January 1, 2023 S7 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS BASEMENT WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE S7)BACKFILL HEIGHT(SEE S7)7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10" 12"8"10" 12"8"10" 12"NONE NONE NONENONE NONENONE NONENONE NONENONENONENONENONENONENONENONENONE NONENONE NONENONENONENONENONENONENONENONENONENONENONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24" 24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)8'-0" OR LESS9'-0" MAX.10'-0" MAX. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 158 3.001 January 1, 2023 S8 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS VERTICAL REINFORCING TABLE Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S7 WOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 16" HIGH MAX x 6" THICK MIN STEM6"MINWOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 6" MIN THICK STEM #4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL FOUNDATION WALL SEE S7 VENEER OR SLAB-ON-GRADE BY OTHERS 12"VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S4 OR S5 FRAMING BY OTHERS 16" HIGH MAX x 4" THICK MIN STEM THICKNESS TO MATCH SILL PLATE6"3'-0" MAXVENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S6 SLAB-ON-GRADE FRAMING BY OTHERS 6" MIN THICK STEM DETAIL @ HIGH GRADE SIM @ NON-BEARING DETAIL @ LOOKOUT SIM @ FROST WALL DETAIL @ FROST WALLS w/ LOW GRADE DETAIL @ LOW GRADE SIM @ NON-BEARING 112" CLEAR MINMAX#4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL (CENTER IN STEMWALL) SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION NOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER. WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 159 3.001 January 1, 2023 S9 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS BRICK LEDGE DETAILS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICK x 2"Ø OR SQUARE WASHER SEE S11 FOR SPACING (7" EMBED MIN) -METAL STRAP ANCHORS TO BE INSTALLED AT MANUFACTURER EQUIVALENT SPACING FLOOR SYSTEM, TYPE, SIZE, AND SPACING TO BE DETERMINED BY OTHERS RIM BOARD OR BRACING MATERIAL BY OTHERS 2x6 SILL PLATE MINIMUM FLOOR TO SILL CONNECTION AT EACH MEMBER SEE TABLE BELOW WASHER TO BE COUNTERSUNK FLUSH w/ TOP OF SILL PLATE SEE FULL HEIGHT WALL SECTION ON S7 FOR FOUNDATION WALL REQUIREMENTS SLOPE GRADE AWAY FROM FOUNDATION MINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS**** BACKFILL TYPECLEAR HEIGHT (SEE S7) FLOOR MEMBER SPACING 16" 19.2" A (4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBER SAND (30 PSF/FT) SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 24" 16" 19.2" 24" 16" 19.2" 24" A A A A A A A B A A B B B B B C C C D D D D D D D C CONNECTION A (4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B (2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC AT EACH MEMBER CONNECTION C CONNECTION D (2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ** OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER * FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES, FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE. ** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH. *** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s. ****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE A STRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE. 2x8 SILL PLATE TO BE USED w/ MAXIMUM OF 112" OVERHANG (MAINTAIN 234" EDGE DISTANCE TO BOTH CONCRETE AND INSIDE OF SILL PLATE) - VERTICAL LOAD TRANSFER BY SUPPLIER 8'-0" OR LESS 9'-0" MAX. 10'-0" MAX. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 1510 3.001 January 1, 2023 S10 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS FLOOR BEARING CONNECTIONS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS* ALTERNATIVE TO CODE TABLE R404.1.(1) BACKFILL TYPE CLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 72" * 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWN SAND (30 PSF/FT)SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 48" 60" 72" 48" 60" 72" 36" 48" 72" 36" 36" 72" 72"72" 48" 24" 24" ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS** ALTERNATIVE TO CODE TABLE R404.1.(1) BACKFILL TYPECLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 48" ** APPLIES TO 12"Ø EXPANSION BOLT w/ 6" EMBED, 12"Ø SELF-CUTTINGANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHOR SAND (30 PSF/FT) SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 60" 72" 30" 36" 72" 18" 24" 42" 72" 72" 24" 18" 20" 24" 18" 24" 24" 30" 42" 16" 12" 14" 16" 12" 16" 36" 36" N/A N/A 8'-0" OR LESS 9'-0" MAX. 10'-0" MAX. 8'-0" OR LESS 9'-0" MAX. 10'-0" MAX. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 1511 3.001 January 1, 2023 S11 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS ANCHOR SPACING TABLES Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR @ BLOCKING SEES102 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWN ORSHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 1512 3.001 January 1, 2023 S12 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS NON BEARING JOIST BLOCKING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE S102 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWN COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 1513 3.001 January 1, 2023 S13 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS NON-BEARING TRUSS BLOCKING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 2 1 $ Q Z 5 J C M Q R G G / 0 10'-0" MAX3'-0" MAX GRADE HEIGHTABOVE TOP OF SLAB1'-6" MIN3'-0" EACH WAY MIN 112" TYPSLOPE GRADE AWAY FROM FOUNDATION #4 HORIZONTAL BARS @ 12" O.C. CENTERED IN WALLS LAP AROUND CORNERS AND HOOK INTO FOUNDATION WALL @ EACH SIDE (REFER TO S7 FOR HORZ. BAR REQUIREMENTS w/ 8" C.I.P. WALLS) 6" MIN C.I.P. CONCRETE WALL #4 VERTICAL BARS @ EACH OUTSIDE CORNER OF WELL (1)#4 x2'-0" DOWEL @ EACH OUTSIDE CORNER OF WELL (5" MIN EMBED) 12" WIDE x 8" THICK MIN STRIP FOOTING (1) #4 HORIZONTAL BAR AT TOP OF WALL (2) #4 HORIZONTAL BARS TOP & BOTTOM OF LINTEL EXTEND 24" MIN PAST OPENING EACH END (WOOD OR STEEL OPTION BY OTHERS) WALL BEYOND PLACE (2) #4 VERTICAL BARS FULL HEIGHT AND ONE ANCHOR w/IN 12" OF OPENING EACH END 8" MIN C.I.P. CONCRETE WALL SLAB-ON-GRADE UNREINFORCED CONCRETE STRIP FOOTING SEE FULL HEIGHT WALL SECTION S7 LOOKOUT WALL SEE S5 GRANULAR MATERIAL (SAND) SLOPE WINDOW WELL LADDER/ ESCAPE MEANS BY OTHERS 5'-0" EACH WAY MAX FLOOR SYSTEM BY OTHERS (DO NOT PLACE GIRDERS OR BEAMS OVER CONCRETE LINTEL DESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL AT THE DISCRETION OF THE BUILDER FOR ADDITIONAL FROST PROTECTION AS REQUIRED PER SITE DESIGN 6" MIN. COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 1514 3.001 January 1, 2023 S14 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS WINDOW WELL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6'-0" MAX. 8" MIN. GRAD E L I N E 9'-4" MAX.6'-0" MAX.4'-0" MAX.SEE BASEMENT WALL DETAILSEE LOOKOUT WALL DETAILSIM.CONSTRUCT SIM. LOOKOUT WALLw/ MIN. (2) #4 HORIZ. BARS3 MIN. 1 S7S5S5SLAB-ON-GRADE BEYOND CONCRETE STRIP FOOTING STEP DOWN AS REQ'D FOR FROST PROTECTION AT NON-BEARING WALLS, LOCATE BLOCKING DETAILS (S12 / S13) AT END OF FULL HEIGHT WALL PROVIDE (2) ADDITIONAL #4 BARS @ END OF FULL HEIGHT WALL SEGMENT LOCATED 2" FROM INSIDE WALL FACE FLOOR FRAMING ABOVE BY OTHERS INFILL WOOD FRAMING BY OTHERS COPYRIGHT HANSON GROUP LLC 2023© City: ofSheet: Drawing Date: Project Number: 1515 3.001 January 1, 2023 S15 Project: Client: RevDateSITE ADDRESS: State:Zip:MN 3407 Kilmer Lane North Suite 4Plymouth, MN 55441 Tel 612-708-3572www.hansongroupmn.com 2023 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS STEPPING DOWN WALL WITH GRADE &TGYU%QPETGVG+PE 2 1 $ Q Z 5 J C M Q R G G / 0 Site address Date 12/14/2023 Contractor Silver Tree Plumbing & Heating, LLC By Jake Ryan Section A Square feet (Conditioned area inc. 4256 TOTAL VENTILATION 160 basement – finished or unfinished)CONTINUOUS VENTILATION 80 Number of bedrooms 4 # of BEDROOMS 1 2 3 4 5 6 Total/ Total/ Total/ Total/ Total/ Total/ continuous continuous continuous continuous continuous continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 150/75 165/;83 180/90 195/98 210/105 225/113 Equation R403.5.2 2015 Mn Energy Code (0.02 x conditioned space) + (15 X (# of bedrooms + 1))= TOTAL VENTILATION RATE Sq Ft 4256 0.02 85.12 Bedrooms 4 15 60 Plus 1 bedroom 15 TOTAL VENT 160.12 CFM Section B Low cfm: High cfm: 80 160 Section D Control Set at 50%80 CFM HIGH set at 90%160 CFM ☒Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Recovery Ventilator) – cfm of unit in low must not exceed continuous ventilation rating by more than 100%. Ventilation Controls (Describe operation and control of the continuous ventilation) (BALANCED) Table R403.5.2 2015 Minnesota Energy Code Total and Continuous Ventilation Rates (in cfm) Conditioned space (in sq. ft.) 2015 Mechanical & Energy Code – Ventilation, Makeup, and Combustion Air Calculations Ventilation Method 17963 Headwaters Drive, Lakeville Ventilation Quantity (Determine quantity by using Table R403.5.2 or Equation R403.5..2, 2015 Minnesota Energy Code) Page 1 of 5 One or multiple power vent or direct vent appliances or no combustion appliances One or multiple fan- assisted appliances and power vent or direct vent appliances One atmospherically vented gas or oil appliance or one solid fuel appliance Multiple atmospherically vented gas or oil appliances or solid fuel appliances Column A Column B Column C Column D 1.Enter the Appropriate Column to Estimate House Infiltration a) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03 b) conditioned floor area (sf) (including unfinished basements) 4256 Estimated House Infiltration (cfm): [1a x 1b]638.4 2. Exhaust Capacity ERV/HRV=0 a) clothes dryer (cfm)135 135 135 135 b) 80% of largest exhaust rating (cfm); (not applicable if recirculating system or if powered makeup air is electrically interlocked and match to exhaust) 240 c) 80% of next largest exhaust rating (cfm); NA (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) Total Exhaust Capacity (cfm);375 [2a + 2b +2c] 3. Makeup Air Quantity (cfm) a) total exhaust capacity (from above)375 b) estimated house infiltration (from above)638.4 Makeup Air Quantity (cfm); [3a – 3b]-263.4 (if value is negative, no makeup air is needed) 4. For makeup Air Opening Sizing, refer to Table 501.4.2 Not Required A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances. (Power vent and direct vent appliances may be used.) B. Use this column if there is one fan-assisted appliance per venting system. (Appliances other than atmospherically vented appliances may also be included.) C. Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. (Additional makeup air will be required for combustion appliances, see KAIR method for calculations) Be advised: 2015 Minnesota Mechanical Code, Section 505.2, Installation of exhaust hood systems capable of exhausting in excess of 400 cfm shall be provide with makeup air at a rate approximately equal to the exhaust air rate. Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system. Directions - In order to determine the makeup air for ventilation, Table 501.4.1 must be filled out (see below). For most new installations, column A will be appropriate, however, if kitchen hoods exceed 300 cfm, atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column. Please note, if the makeup air quantity is negative, no additional makeup air will be required for ventilation, if the value is positive refer to Table 501.4.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to the last line of section D. The ventilation make-up air supply must communicate with the exhaust appliances. Table 501.4.1, 2015 Minnesota Mechanical Code PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST APPLIANCES IN DWELLING UNITS Page 2 of 5 Section E Passive (determined from calculations from 2015 Minnesota Mechanical Code, Table 501.4.1) Powered (determined from calculations from 2015 Minnesota Mechanical Code, Table 501.4.1) Interlocked with exhaust device (determined from calculations from 2015 Minnesota Mechanical Code, Table 501.4.1) Other, describe: Location of duct or system ventilation make-up air: (Determined from make-up air opening table, Table 501.4.2.) Not Required -263.4 Makeup Air Opening Table for New and Existing Dwelling Table 501.4.2, 2015 Minnesota Mechanical Code One or multiple power vent, direct vent appliances, or no combustion appliances One or multiple fan- assisted appliances and power vent or direct vent appliances One atmospherically vented gas or oil appliance or one solid fuel appliance Multiple atmospherically vented gas or oil appliances or solid fuel appliances Column A Column B Column C Column D Duct diameter Passive opening 1 – 36 1 – 22 1 – 15 1 – 9 3 Passive opening 37 – 66 23 – 41 16 – 28 10 – 17 4 Passive opening 67 – 109 42 – 66 29 – 46 18 – 28 5 Passive opening 110 - 163 67 – 100 47 – 69 29 – 42 6 Passive opening 164 – 232 101 – 143 70 – 99 43 – 61 7 Passive opening 233 – 317 144 – 195 100 – 135 62 – 83 8 Passive opening w/motorized damper 318 – 419 196 – 258 136 – 179 84 – 110 9 Passive opening w/motorized damper 420 – 539 259 – 332 180 – 230 111 – 142 10 Passive opening w/motorized damper 540 – 679 333 – 419 231 – 290 143 – 179 11 Powered makeup air >679 >419 >290 >179 NA Notes: A. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90- degree elbow to determine the remaining length of straight duct allowable. B. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. Compressed duct shall not be accepted. C. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. D. Powered makeup air shall be electrically interlocked with the largest exhaust system. Sections F X Size and type FLEX= NR RIGID= NR Other, describe: Make-up air for VENTILATION Size and type (round, rectangular, flex or rigid) Directions - The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening, is called the Known Air Infiltration Rate Method (KAIR). For new construction, 4b of step 4 is required to be filled out. The example assumes a typical 3,000 square foot home with a finished basement that has a mechanical room that is 10 feet wide by 12 feet long with an 8 foot ceiling. It also assumes installation of a 70,000 btu, 2 pipe condensing furnace; and a 40,000 Btu, power vented water heater. Make-up air for COMBUSTION Passive (see IFGC Appendix E, Worksheet E-1) Explanation - If no atmospheric or power vented appliances are installed, check the appropriate box, not required. If a power vented or atmospherically vented appliance installed, use IFGC Appendix E, Worksheet E-1 (see below). Please enter size and type. Combustion air vent supplies must communicate with the appliance or appliances that require the combustion air. Not required per mechanical code (No atmospheric or power vented appliances) Page 3 of 5 Furnace/Boiler: Water Heater: INPUT in BTUHS:0 CAS VOLUME:2304 Mech Room Length:32 Mech Room Width:9 Mech Room Height:8 Cubic feet INPUT (BTUH/HOUR)= TRV (ft3)= INPUT (BTUH/HOUR)=0 RVFA (Ft3)=3000 INPUT (BTUH/HOUR)=0 RVNFA (Ft3)=NONE RVFA:3000 RVNFA (Ft3)=0 3000 Ft3 RATIO=2304 DIVIDED BY 3000 EQUALS:0.77 RF = 1 minus Ratio Ratio RF=1 MINUS 0.77 EQUALS:0.23 INPUT (BTUH/HOUR)=0 CAOA=0 divided by 3000 EQUALS:0.00 BTUH/HR per in2 MIN CAOA=0.00 X 0.23 0.00 Square Inches CAOD= 1.13 X Square root Minimum CAOA=0.00 inches1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section G304 Minimum CAOA = CAOA multiplied by RF Step 9: Calculate Combustion Air Opening Diameter (CAOD) CAOD = 1.13 multiplied by the square root of Minimum CAOA Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per in2 Step 8: Calculate Minimum CAOA. If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Step 6: Calculate Reduction Factor (RF). (DO NOT COUNT DIRECT VENT APPLIANCES) Use Fan-Assisted Appliances column in Table E-1 to find Required Volume Fan Assisted (RVFA) Total Btu/hr input of all non-fan-assisted appliances Use Non-Fan-Assisted Appliances column in Table E-1 to find Required Volume Non-Fan-Assisted (RVNFA) Total Required Volume (TRV) = RVFA + RVNFA IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method Total Btu/hr input of all fan-assisted and power vent appliances Step 4: Determine Required Volume for Combustion Air. 4a. Standard Method Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. Step 3: Determine Air Changes per Hour (ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method). If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. 4b. Known Air Infiltration Rate (KAIR) Method __ Draft Hood (Non- fan assist) __ Fan Assisted & Power Vent __ Direct Vent _X_Electric Total Btu/hr input of all combustion appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Use Standard Method column in Table E-1 to find Total Required Volume (TRV) Step 1: Complete vented combustion appliance information. __ Draft Hood __ Fan Assisted __-Direct Vent XX FURNACE IS SEALED COMBUSTION (for Furnace, Boiler, and/or Water Heater in the Same Space) Page 4 of 5 Input Rating (Btu/hr) 1994 to present Pre-1994 1994 to present Pre-1994 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,675 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8.625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 1.     The 1994 date refers to dwelling constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is .20 air changes per hour (ACH). 2.     This section of the table is to be used for dwelling constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH. Although this worksheet, IFGC Appendix E, Worksheet E-1 and the following worksheet, IFGC Appendix E, Table E-1, is referenced in the 2015 Minnesota Fuel Gas Code, these worksheets were not included in the published copy. IFGC Appendix E, Table E-1 Residential Combustion air (Required Interior Volume Based on Input Rating of Appliance) Standard Method Known Air Infiltration Rate (KAIR) Method (cu ft) Fan Assisted Non-Fan Assisted Page 5 of 5 17963 Headwaters Dr, Lakeville HVAC Load Calculations for Country Joe Homes 22260 Dodd Blvd Lakeville, MN 55044 Prepared By: Jake Ryan Silver Tree Plumbing & Heating 1335 Mendota Heights Rd Mendota Heights, MN 55120 651-900-7053 Thursday, December 14, 2023 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17963 Headwaters Dr, Lakeville Eagan, MN 55121 Page 2 Project Report General Project Information Project Title:17963 Headwaters Dr, Lakeville Designed By:Jake Ryan Project Date:12/14/2023 Project Comment:Stoneleigh - walkout Client Name:Country Joe Homes Client Address:22260 Dodd Blvd Client City:Lakeville, MN 55044 Client Phone:(952) 469-4066 Company Name:Silver Tree Plumbing & Heating Company Representative:Jake Ryan Company Address:1335 Mendota Heights Rd Company City:Mendota Heights, MN 55120 Company Phone:651-900-7053 Company E-Mail Address:jaker@silvertreepandh.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces North Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 n/a 30%72 33.90 Summer:88 73 50%50%72 42 Check Figures Total Building Supply CFM:993 CFM Per Square ft.:0.233 Square ft. of Room Area:4,256 Square ft. Per Ton:1,771 Volume (ft³):36,175 Building Loads Total Heating Required Including Ventilation Air:49,776 Btuh 49.776 MBH Total Sensible Gain:22,103 Btuh 77 % Total Latent Gain:6,728 Btuh 23 % Total Cooling Required Including Ventilation Air:28,831 Btuh 2.40 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\17963 Headwaters Dr, Lakeville - Heat Calc.rh9 Thursday, December 14, 2023, 10:19 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17963 Headwaters Dr, Lakeville Eagan, MN 55121 Page 3 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Min Htg CFM Min Clg CFM Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.40 1,771 4,256 22,103 6,728 28,831 49,776 593 993 593 993 993 System 1 Main Floor No 2.40 1,771 4,256 22,103 6,728 28,831 49,776 593 993 593 993 993 11x16 Ventilation 902 4,397 5,298 5,497 160 160 160 Humidification 6,430 Zone 1 4,256 21,202 2,331 23,533 37,850 593 993 593 993 993 11x16 1-Basement 2,128 3,372 0 3,372 15,540 243 158 243 158 158 2--5 2-Main Level 2,128 17,830 2,331 20,161 22,310 349 835 349 835 835 7--6 F:\ ...\17963 Headwaters Dr, Lakeville - Heat Calc.rh9 Thursday, December 14, 2023, 10:19 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17963 Headwaters Dr, Lakeville Eagan, MN 55121 Page 4 Duct Size Preview Room or Duct Name Source Minimum Velocity Maximum Velocity Rough. Factor Design L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size Reg Size System 1 Supply Runouts Zone 1 1-Basement Built-In 450 750 0.01 0.1 579.3 243 158 158 2--5 2-Main Level Built-In 450 750 0.01 0.1 607.8 349 835 835 7--6 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 812.7 593 993 993 11x16 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:593 Cooling Flow:993 F:\ ...\17963 Headwaters Dr, Lakeville - Heat Calc.rh9 Thursday, December 14, 2023, 10:19 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17963 Headwaters Dr, Lakeville Eagan, MN 55121 Page 5 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain Anderson 100: Glazing-Anderson 100, ground reflectance = 0.23, indoor insect screen with 100% coverage, U-value 0.27, SHGC 0.28 421.6 9,903 0 7,613 7,613 11D: Door-Wood - Solid Core, U-value 0.39 20 679 0 211 211 11J: Door-Metal - Fiberglass Core, U-value 0.6 20 1,044 0 324 324 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 2146.4 12,138 0 2,274 2,274 15B0-10sf-8: Wall-Basement, , R-10 board insulation to floor, no interior finish, 8' floor depth, U-value 0.05, above grade U-value 0.083 1200 5,220 0 0 0 RJ R-20: Wall-Frame, Custom, RJ R-20 RIM JOIST R20 SPRAY FOAM, U-value 0.05 336 1,460 0 344 344 R49 Attic: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, R49 Attic, U-value 0.02 2128 3,703 0 3,022 3,022 21A-32: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 32' wide, U-value 0.02 2128 3,703 0 0 0 Subtotals for structure:37,850 0 13,788 13,788 People:6 1,200 1,380 2,580 Equipment:1,131 4,262 5,393 Lighting:400 1,364 1,364 Ductwork:0 0 0 0 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 160, Summer CFM: 160 5,497 4,397 902 5,298 Humidification (Winter) 17.53 gal/day :6,430 0 0 0 AED Excursion:0 0 408 408 Total Building Load Totals:49,776 6,728 22,103 28,831 Check Figures Total Building Supply CFM:993 CFM Per Square ft.:0.233 Square ft. of Room Area:4,256 Square ft. Per Ton:1,771 Volume (ft³):36,175 Building Loads Total Heating Required Including Ventilation Air:49,776 Btuh 49.776 MBH Total Sensible Gain:22,103 Btuh 77 % Total Latent Gain:6,728 Btuh 23 % Total Cooling Required Including Ventilation Air:28,831 Btuh 2.40 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\ ...\17963 Headwaters Dr, Lakeville - Heat Calc.rh9 Thursday, December 14, 2023, 10:19 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17963 Headwaters Dr, Lakeville Eagan, MN 55121 Page 6 Building Rotation Report All rotation degree values in this report are clockwise with respect to the project's original orientation. Building orientation as entered (zero degrees rotation): Front door faces North Individual Rooms Rm. No. Room Name 0° Rot. CFM 45° Rot. CFM 90° Rot. CFM 135° Rot. CFM 180° Rot. CFM 225° Rot. CFM 270° Rot. CFM 315° Rot. CFM High Duct Size System 1: Zone 1: 1 Basement 158 216 *235 178 114 173 213 198 2--6 2 Main Level 835 994 *1,022 908 771 891 939 921 9--6 * Indicates highest CFM of all rotations. Whole Building Rotation Degrees Front door Faces Supply CFM Sensible Gain Latent Gain Net Tons 0°North 993 22,103 *6,728 2.40 45°Northeast 1,210 26,722 6,728 2.79 90°East *1,257 *27,722 6,728 *2.87 135°Southeast 1,086 24,079 6,728 2.57 180°South 884 19,778 6,728 2.21 225°Southwest 1,064 23,618 6,728 2.53 270°West 1,152 25,483 6,728 2.68 315°Northwest 1,118 24,773 6,728 2.63 * Indicates highest value of all rotations. 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 North Northeast East Southeast South Southwest West NorthwestCooling TonsDirection Front door Faces Building Rotation Tonnage Building Net Tonnage F:\ ...\17963 Headwaters Dr, Lakeville - Heat Calc.rh9 Thursday, December 14, 2023, 10:19 AM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 17963 Headwaters Dr, Lakeville Eagan, MN 55121 Page 7 Building Rotation Report (cont'd) 25,000 26,000 27,000 28,000 29,000 30,000 31,000 32,000 33,000 34,000 35,000 36,000 37,000 38,000 39,000 8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pmBuilding Net Gain, BtuhTime of Day Building Rotation Hourly Net Gain Front door faces North Front door faces Northeast Front door faces East Front door faces Southeast Front door faces South Front door faces Southwest Front door faces West Front door faces Northwest F:\ ...\17963 Headwaters Dr, Lakeville - Heat Calc.rh9 Thursday, December 14, 2023, 10:19 AM Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is required for “Construction activity that results in land disturbance of equal to or greater than one (1) acre or if a project is part of a common plan of development that will ultimately disturb greater than one (1) acre,” (NPDES Permit, Section 1.2). Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ *Primary Company Contact: _________________________________________________________________ *Should a site be deemed noncompliant, this individual will be notified Phone #: ____________________________ Email: ______________________________________________ If you are not covered under a NPDES Construction Stormwater Permit administered by the Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be approved as part of the residential building permit application. “Permittees must ensure a trained person will inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than ½ inch in 24 hours,” (NPDES Permit, Section 11.2). The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name: ____________________________________ Company: ___________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: __________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001). Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 952-215-6391 rjarvi@countryjoehomes.com Rob Jarvi Youngfield Homes Rob Jarvi Youngfield Homes 952-215-6391 rjarvi@countryjoehomes.com University of Minnesota 05/31/24 Steve Sauber 17963 HEADWATERS DRIVE 12/21/23