HomeMy WebLinkAboutLA220211 - 17700 Ellsworth Drive - Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
_____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
NAME OF APPLICANT (Please Print)DATE
I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS
APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO
COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH
LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED
PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE
CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE
ESCROW APPLICATION AND REFUND.
OFFICE PHONE #:_
OFFICE PHONE #:_
*Entering your name affirms your intent to comply with the statement above.
*
Submit Application To: permits@lakevillemn.gov
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT
CONDO
REROOF
RESIDE
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES
LOWER LEVEL FINISH
ADDITION
FOUNDATION ONLY
MISCELLANEOUS
DEMO
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
CITY BUILDING VALUATION: $
BUILDING PERMIT FEES
$PERMIT FEE
$PLAN CHECK
$SURCHARGE
$METRO SAC
$CITY WATER HOOKUP UNIT
$CITY SEWER HOOKUP UNIT
$LANDSCAPE ESCROW
$TREE ESCROW
$MISC ESCROW
$PLUMBING
$MECHANICAL
$SEWER WATER
WATER METER
PRESSURE REDUCING VALVE
$OTHER
$TOTAL
METER SIZE
PRESSURE REDUCING VALVE
SEWER/WATER
SEWER/WATER
FINAL
STREET DRAINTILE
BUILDING INFORMATION
TYPE OF CONSTRUCTION
ZONING
CODE EDITION
FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
MECHANICAL
AIR TEST
FINAL
ROUGH-IN
PLUMBING
FINAL
ROUGH-IN
INSULATION
LATH
DECK FOOTING
FIREPLACE
FOOTING
FOUNDATION
FRAMING
PORCH FRAMING
PORCH FOOTING
POURED WALL
SITE
LOWER LEVEL FINAL
OTHER
DECK FRAMING
LOWER LEVEL FRAMING
LANDSCAPING
DECK FINAL
$
$
ACCESSORY BUILDING
EGRESS WINDOW
UNDERGROUND
MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -6 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"GARAGE PLATE HEIGHT10' - 9 3/8"SMARTSIDE FRIEZEBOARD @ FRONT TYP.VINYL BOARD & BATTEN CULTURED STONEW/ CONCRETE CAPALUMINUM SOFFIT& FASCIA TYP.6" BUMP-OUT GABLE END W/ VINYL BOARD & BATTEN ADDRESS STONE 6"x6"x30" CORBELS TYP.8" SMARTSIDEFRIEZE BD.3' - 6"3' - 6"6" BUMP-OUT GABLE END W/ VINYL BOARD & BATTENW/ PAINTED CORBELS SEE COLUMN DETAIL SHEET A-5018" / 12"8" / 12"8" / 12"5" / 12"5" / 12"10" 12"10" 12"10" 12"12036 NVH1R.O. 2' -0" x 3' -6"H.H. 12' -9 3/4"3' - 6"VINYL SIDING &CORNERS TYP.6" SMARTSIDE WINDOW & DOOR TRIM TYP. @ FRONT 24" RETURN TYP.8" 12"7" / 12"10" / 12"10" / 12"8" / 12"5" 12"MAIN FLOOR1' -8 1/4"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING &CORNERS @SIDES & REAR OWNER'S SUITE PLATE21' -7 1/4"OWNER'S SUITE FLOOR13' -6 1/8"GREAT RM. PLATE11' -9 3/8"10' - 1 1/8"8' - 1 1/8"8" / 12"5" / 12"7" 12"24" RETURN TYP.8" 12"5" 12"10" / 12"10" / 12"10" / 12"7" / 12"0' - 5 1/2"0' - 5 1/2"6x60' - 5 1/2"FRONT VIEWSIDE VIEW 0' - 2"0' - 3 1/2"0' - 3 1/2"0' - 5 1/2"R 0' - 2"0' - 5 1/2"2' - 6"6x60' - 5 1/4"0' - 5 1/4"FRONT VIEWSIDE VIEW 0' - 2 1/8"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 4:49:42 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-201OTT40710.18.23 CB16111539119111.7.23 CB10.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKE1/4" = 1'-0"A-2011FRONT ELEVATION1/8" = 1'-0"A-2012RIGHT ELEVATION1/8" = 1'-0"A-2013REAR ELEVATION1/8" = 1'-0"A-2014LEFT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONSA-401 FOUNDATIONA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 ROOF/ SCHEDULES/ DETALSA-502 DETAILS3/4" = 1'-0"A-2015CORBEL DETAIL - 6x61/2" = 1'-0"A-2016CORBEL DETAIL - 6x6x30Secure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode11/09/2023jnuetzman
19' - 10"1' - 10"2' - 0"1' - 10 1/2"16' - 3" M.O.1' - 10 1/2"0' - 7 1/2"8' - 3" M.O.1' - 7 1/2"8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"0' - 4"* ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATION12' - 7 1/4"3' - 10 3/4"3' - 10 3/4"17' - 9 1/4"8' - 11 3/4"17' - 10 1/4"2' - 10"8' - 0 1/2"5' - 4 1/4"2' - 0 1/4"3' - 11"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.12' - 0"38' - 2"5' - 10"2' - 0"7' - 10"50' - 2"19' - 4"1' - 0"20' - 0"10' - 6"30' - 6"19' - 6"4' - 0"23' - 8"23' - 4"7' - 0"27' - 8"30' - 4"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.* ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATION6' - 0"2' - 2"36' - 0"9' - 0"11' - 6"3' - 10 3/4"15' - 11 1/4"29' - 8"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY50' - 0"1' - 0"7' - 8 3/4"15' - 11 1/4"42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY48" x 48" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAYLEAVE A 12" GAP IN THE FOOTING FOR PLUMBING 1' - 0"49' - 0"18' - 0"16' - 0"15' - 0"58' - 0"58' - 0"4' - 9 1/4"8' - 5 1/2"4' - 9 1/4"15' - 8 3/4"15' - 3 1/4"42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY5' - 3 1/4"18' - 0 3/4"50' - 0"48" x 48" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY11' - 11 1/4"7' - 4 3/4":LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODESTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAYANCHOR BOLTS ON EACH SIDEOF BEARING POINT TYPICALTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 4:49:43 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-401OTT40710.18.23 CB16111539119111.7.23 CB10.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKE1/4" = 1'-0"A-4011FOUNDATION PLAN
UNEXCAVATEDUNEXCAVATED4-14" LVL DROPPED 8"0' - 4"2" FOAM INSULATIONBETWEEN WALL & SLAB62/8 x 6/8R.O. 2' -10" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"(5) 16" SH.62/8 x 6/8R.O. 2' -10" x 6' -11"MECHANICALBATHFAMILY ROOMGAME ROOMFURNACEW. H.F. D.SUMPAIR EX.3' - 8"15' - 8"0' - 4"2' - 0"5' - 10"38' - 2"12' - 0"7' - 10"50' - 2"19' - 4"1' - 0"CANT. JOIST2' - 0"1' - 10"19' - 10"9' - 0"11' - 6"30' - 6"19' - 6"15' - 0"16' - 0"18' - 0"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2 TRIMMERS EA. SIDE 2-9 1/2" LSLDROPPED 2-2x10*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/ SHEATHING*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/ SHEATHING12' - 10"3' - 8"3' - 8"18' - 0"CO DET.SMOKEDET.SMOKEDET.7x7 PSL W/ COLUMN CAPECCQ7.1-7.1SDS2.5 W/ STRAPS ROTATED 90°NO PLATES 36' - 0"2' - 2"6' - 0"1' - 10"27' - 8"30' - 4"20' - 0"10' - 6"1' - 0"29' - 8"18" CANT. ABOVE 50' - 0"7' - 0"23' - 4"23' - 8"4' - 0"12' - 6 1/4"18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING85040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"2' LINEN6' VANITY42/6 x 6/8R.O. 2' -8" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"6' - 6 1/4"4' - 2 3/4"0' - 8"11' - 11"12/4 x 6/8R.O. 2' -6" x 6' -11"R & SH.3' - 10 1/4"11' - 4"BEDROOM #548" F.G. SHWRHALF WALL6' - 2"4' - 2"1' - 0"49' - 0"50' - 0"CLOSET2x6.58' - 0"58' - 0"3-2x102-2x10 FLUSHGIRDER TRUSS4-2x6 W/ SQUASH BLOCKING 2x8EQEQGAS LINE FOR FUTURE FIREPLACE GAS LINE FOR FUTURE GRILL9' - 0"9' - 0"8' - 0"8' - 0"7' - 6"7' - 6"108040E NVGER.O. 8' -0" x 4' -0"H.H. 6' -10"116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"6' - 3"5' - 9"85040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"5x7 PSLSTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.3' - 3"B.W.P.4' - 0"B.W.P.4' - 0"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES3-9 1/2" LVL W/3 TRIMMERS 2-2x102-2x10ANCHOR BOLTS ON EACH SIDEOF BEARING POINT TYPICAL9' - 0"5' - 10"4' - 6"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 4:49:45 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-402OTT40710.18.23 CB16111539119111.7.23 CB10.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKE1/4" = 1'-0"A-4021LOWER FLOOR PLANFANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).
12' - 0"38' - 0"6' - 0"2' - 0"1' - 0"49' - 0"SINGLE BOWLUNDERMOUNTSINK S.S.DWPORCH19' - 6"30' - 6"1' - 9"8' - 0"0' - 9"2' - 0"16' - 0"2' - 0"1' - 0"4" REINFORCED CONCRETE SLAB,SLOPE TOWARDS DOORS5/8" TYPE X GYP. BD. CEILING1/2" GYP. GB. ON GARAGE WALLS GARAGE PLATE HEIGHT TOMATCH MAIN FLOOR PLATER-38 MIN INSULATION IN FLOOR ABOVE 128' x 8' O.H. GARAGE DOOR8' - 0"50' - 0"18' - 0"16' - 0"15' - 0"GARAGEDBLOVENGAS F.P.30' - 0"EQEQFULL HEIGHT IRONSPINDLE RAILING 18' - 0"3' - 8"3' - 8"12' - 8"SEE COLUMN DETAIL SHEET A-50150' - 0"2' - 0"17' - 0"3' - 0"LOCKERS.83/0 x 6/8 ARCH4' - 3 1/2"5' - 0"3' - 4"9' - 0"3' - 6"CLOSETPOWDERMUD RM.12/4 x 6/8R.O. 2' -6" x 6' -11"42" PANTRY36" REF36" GASCOOKTOPW/ HOOD42" HALF WALLW/ WOOD CAPDINING2' - 0"STONE TO CEILING93/0 x 6/8 W/ 2-12" D.S. S.L.'SSTEEL7' - 10"0' - 10"5' - 10"4' - 6"GREAT ROOM5' - 4 1/4"5' - 1 3/4"5' - 6"7' - 0"5' - 0"6' - 2"PED. SINKGIRDER TRUSSWHITE PAINTED CABINETS & TILE BACKSPLASHKITCHEN3-14" LVL FLUSH CONTINUOUS5' - 9"3' - 9"5' - 9 1/4"7' - 10"11' - 2"OFFICEFOYER4' - 0"9' - 3"5' - 9"19' - 0"2' - 0"3' - 6"2' - 0"19' - 6"3' - 0"58' - 0"12' - 10"2' - 2"8' - 0"8' - 0"8' - 6"9' - 6"0' - 8" TYP.38' - 0"5' - 4"0' - 8"B.W.P.4' - 0"B.W.P.8' - 0"B.W.P.6' - 5"B.W.P.2' - 8"B.W.P.2' - 7"5' - 9"6' - 3"B.W.P.3' - 7"B.W.P.8' - 0"B.W.P.4' - 0"4' - 0" B.W.P.B.W.P.2' - 3"B.W.P.2' - 8"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"3-2x63-2x63-18" LVL FLUSH2-2x123-9 1/2" LSL2-2x102-9 1/2" LSL CONT.W/ 2 TRIMMERS EA. SIDE 5'-0" COUNTER HGT.BUFFET W/ TILE BACKSPLASH1' - 1"3-16" LVL FLUSHTRASH PULLOUT B.W.P.8' - 0"SMOKEDET.20' - 0"10' - 6"8' - 0"11' - 6"0' - 8"7' - 8"0' - 8"10' - 10"0' - 8"WALL ABOVE BEARING ON FLOOR TRUSSESB.W.P.4' - 0"4-TRIMMERSFRIDGE RECESS 39"x73"x2"MONO GIRDER2-2x10 DROPPED3-2x10 DROPPED3-2x10DROPPED 2-TRIMMERS EA. SIDE2-2x10 SET 6" OFF FIREPLACE @ FINISHED FLOOR 12"x12" GYP.BD. SOFFIT12/4 x 6/8R.O. 2' -6" x 6' -11"MICROCABINET 9"x5' ISLANDW/ 6" LEGSFLUSH SNACK BAR1316' x 8' O.H. GARAGE DOOR2-2x102-2x102' - 0"0' - 8"1' - 4"0' - 6" TYP.28' - 0"30' - 0"3' - 4"3' - 8"58' - 0"50' - 0"STEP IN FLOOR ABOVE10'-1 1/8" CEILING9'-1 1/8" CEILING4' - 0"24' - 0"23' - 0"7' - 0"LUS210-32-11 7/8" LSL2-2x105x7 PSL NO SPF PLATES SYP PLATES OK 2-2x12 CONTINUOUS 5x5 PSL W/ COLUMN CAPCCQ66SD2.5 NO PLATES4-2x6 SYP PLATES OK1' - 6"2-2x10DROPPED@ 6'-8" H.H. VAULT LINE 3.5:123.5:1218" DEEP PULLOUTS U.C. LIGHTU.C. LIGHTU.C. LIGHT4' - 3"12' - 3"STAINED WOODTOP ON 36" FRAMED WALLW/ (1) SHELF 5' - 3"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES32 FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.2' - 0"6' - 0"53350E NVH1R.O. 3' -3" x 5' -0"H.H. 6' -10"773650 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 6' -11 1/2"H.H. 8' -0"773650 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 6' -11 1/2"H.H. 8' -0"53350E NVH1R.O. 3' -3" x 5' -0"H.H. 6' -10"5' - 9 1/4"9' - 6"63636 NVG1R.O. 3' -6" x 3' -6"H.H. 6' -10"22/4 x 6/8 ARCH16" SH.16" SH.PANTRYPFH2' - 0"PFH2' - 0"PFH1' - 9"72/8 x 6/8R.O. 2' -10" x 6' -10 1/4"B.W.P.3' - 6"73650 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 6' -11 1/2"H.H. 8' -0"116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"B.W.P.2' - 8"2' - 0"5' - 4"0' - 8"6' - 0"2-2x102-2x10 DROPPED HANGER INTO SIDE OF PSL W/ HUC28-23-2x64' - 0"77CS-PF2' - 1"CS-PF2' - 1"12/4 x 6/8R.O. 2' -6" x 6' -11"B.W.P.2' - 8"B.W.P.4' - 0"2' - 0"8' - 7"3' - 7"105/0 x 6/8 FULL VIEWR.O. 5' -2" x 6' -11"9" HEAT DUCTHGUS5.50/144-2x65x7 PSL NO SPF PLATES SYP PLATES OK R & SH @ 68"9' - 0"DBL. FRAMED WALLFOR REFG. RECESSU.C. LIGHTBUILT-IN CAB.BUILT-IN CAB.31" (W)x 18" (T)RECESS FOR TV MOUNT ABOVEADD BLOCKING FUTURE U.C. REF SHALLOWBASE1' - 7"ELONGATED 2 TRIMMERS 5x5 PSL DIRECT FROM SUPPORT MEMBER TO HEADER 2-9 1/2" LSL1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 4:49:47 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-403OTT40710.18.23 CB16111539119111.7.23 CB10.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKEBWPsAboveVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).
CO DET.SMOKEDET.SMOKEDET.SMOKEDET.SMOKEDET.EN SUITEPRIMARY SUITEVAULTEDBEDROOM #3HALLBEDROOM #412' - 8"3' - 8"3' - 8"18' - 0"4' - 0"1' - 0"15' - 0"18' - 0"16' - 4"21' - 8"30' - 8"5' - 10"4' - 6"52/6 x 6/8 PKTR.O. 5' -2" x 6' -11"BEDROOM #262/8 x 6/8R.O. 2' -10" x 6' -11"ATTICACCESS12/4 x 6/8R.O. 2' -6" x 6' -11"R & SH @ 68"9'-0" VANITY10' - 3"3' - 9"6' - 4"4' - 2"3' - 11"5' - 7"15' - 0"5' - 0"9' - 2"3' - 10"7' - 3"15' - 2 7/8"19' - 0 1/8"7' - 6"49' - 0"10' - 0"9' - 0"4' - 0"9' - 3"5' - 9"2-9 1/2" LSLB.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 9"B.W.P.4' - 0"B.W.P.2' - 8"B.W.P.4' - 0"B.W.P.4' - 0"42/6 x 6/8R.O. 2' -8" x 6' -11"3'-6" VANITY42/6 x 6/8R.O. 2' -8" x 6' -11"62/8 x 6/8R.O. 2' -10" x 6' -11"6' - 4"3' - 6"2' - 9"3' - 0"2' - 5"SEATCONTROLS (2) SHELVES STACKEDTILE SHOWER R & SH @ 42" & 84"R & SH @ 42" & 84"12/4 x 6/8R.O. 2' -6" x 6' -11"PRIMARYCLOSET48" TALL WALL W/GLASS PANEL12/4 x 6/8R.O. 2' -6" x 6' -11"HOOK WALL R & SH @ 68"5-SHELVESCLOSETLAUNDRYBATH12/4 x 6/8R.O. 2' -6" x 6' -11"16" SH.9" SH.(5)12/4 x 6/8R.O. 2' -6" x 6' -11"5'-9" VANITY -TALLLINEN5' TUB/SHWR2x6CLOSETBATH6' - 0"7' - 0"3' - 11 1/2"5' - 4 1/2"2' - 3"6' - 1"3' - 10"6' - 2"8' - 0"3' - 0"19' - 0"19' - 0"6' - 0"4' - 0"2' - 8"49' - 0"38' - 0"38' - 0"STORAGE2-2x102-2x10 2-2x6 EA. SIDE 2-2x10 GIRDER TRUSS42/6 x 6/8R.O. 2' -8" x 6' -11"32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"2x65' TUB/SHWR12/4 x 6/8R.O. 2' -6" x 6' -11"13' - 0"6' - 0"R & SH @ 68"12/4 x 6/8R.O. 2' -6" x 6' -11"L.T.CLOSET2-2x102-2x103-2x63-2x62-2x104-2x6TILECURB32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"48" LINEN2' - 6"2x6 KNEE WALL W/14" PAINTEDSPINDLES CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.SMOKEDET.CO DET.118050E NVGER.O. 8' -0" x 5' -0"H.H. 6' -10"96020 NVFA3R.O. 6' -0" x 2' -0"H.H. 6' -10"43050E NVC1R.O. 3' -0" x 5' -0"H.H. 6' -10"33020 NVPWGR.O. 3' -0" x 2' -0"H.H. 6' -10"85040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"4522626 NVFA1R.O. 2' -6" x 2' -6"H.H. 6' -10"53350E NVH1R.O. 3' -3" x 5' -0"H.H. 6' -10"B.W.P.4' - 0"B.W.P.2' - 8"B.W.P.2' - 8"R & SH @ 68"SPRAY FAOM SMOKEDET.0' - 9"0' - 6"4:12 ELONGATED DRYERWASHER4' - 7"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 4:49:49 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-404OTT40710.18.23 CB16111539119111.7.23 CB10.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKE1/4" = 1'-0"A-4041UPPER FLOOR PLANFANFANFANFAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).
6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANS1' - 6"2x4 TYP.2x42x4 @ TOPSOFFITFRONTSIDETOP VIEWSMOOTHSMARTSIDETYPICAL4x4 POSTFRAMING1' - 6"1' - 6"1' - 6"1' - 3"1' - 3"1' - 8"1' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGS9' - 1 1/8"6' - 8"R=1'-7"3' - 0"1' - 4"ALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSSWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER FLOOR PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATIONSTANDARD ENERGY HEELS @ 8:12 W/10:12 FASCIA LINES TO MATCH 18" OVERHANGS & 12" RAKES TYP. 8 ROOF VENTS REQUIRED STANDARD ENERGY HEELS @ 5:12 W/ 7:12, 8:12 & 10:12 FASCIA LINES TO MATCH 5:12 RAISED HEEL2 ROOF VENTS REQUIRED 1 ROOF VENT REQUIRED 8" / 12"8" / 12"7" / 12"7" / 12"5" / 12"8" / 12"8" / 12"10" / 12"10" / 12"10" / 12"10" / 12"5" / 12"10" / 12"10" / 12"5" / 12"8" / 12"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 4:49:51 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-501OTT40710.18.23 CB16111539119111.7.23 CB10.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKE1/2" = 1'-0"A-5011TYP. POURED WALKOUT SECTION1/2" = 1'-0"A-5012TYP. POURED LOOKOUT SECTION1/2" = 1'-0"A-5013TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5014TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5015TYP. COLUMN1/2" = 1'-0"A-5017BEARING WALL SECTION1/2" = 1'-0"A-5018ARCH DETAIL1/2" = 1'-0"A-5019GARAGE CEILING3/8" = 1'-0"A-50110TYP. POURED WALL SECTION1/8" = 1'-0"A-50111ROOF PLANWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT COMMENTS1 VECTOR ENVISION SERIES 1 2036 NVH1 2' - 0" 3' - 6" 12' - 9 3/4"2 VECTOR ENVISION SERIES 1 2626 NVFA1 2' - 6" 2' - 6" 6' - 10"3 VECTOR ENVISION SERIES 1 3020 NVPWG 3' - 0" 2' - 0" 6' - 10" OBSCURE GLASS4 VECTOR ENVISION SERIES 2 3050E NVC1 3' - 0" 5' - 0" 6' - 10"5 VECTOR ENVISION SERIES 4 3350E NVH1 3' - 3" 5' - 0" 6' - 10"6 VECTOR ENVISION SERIES 1 3636 NVG1 3' - 6" 3' - 6" 6' - 10"7 VECTOR ENVISION SERIES 7 3650 NVPWG/3620 NVA1 TEMP. 3' - 6" 6' - 11 1/2" 8' - 0"8 VECTOR ENVISION SERIES 3 5040E NVG1 5' - 0" 4' - 0" 6' - 10"9 VECTOR ENVISION SERIES 1 6020 NVFA3 6' - 0" 2' - 0" 6' - 10"10 VECTOR ENVISION SERIES 1 8040E NVGE 8' - 0" 4' - 0" 6' - 10"11 VECTOR ENVISION SERIES 1 8050E NVGE 8' - 0" 5' - 0" 6' - 10"ROOM FINISH SCHEDULEFLOOR ROOM NAME AREA FLOOR FINISH CEILING HEIGHT COMMENTSLOWER FLOOR MECHANICAL 208 SF 8' - 2"LOWER FLOOR BEDROOM #5 158 SF CARPET 8' - 2" .LOWER FLOOR FAMILY ROOM 598 SF CARPET 8' - 2" .LOWER FLOOR GAME ROOM 181 SF CARPET 8' - 2" .LOWER FLOOR CLOSET 47 SF CARPET 8' - 2"LOWER FLOOR BATH 68 SF VINYL 8' - 2" .MAIN FLOOR PANTRY 42 SF 9' - 1 1/8"MAIN FLOOR GREAT ROOM 287 SF CARPET 10' - 1 1/8" 10'-1 1/8" PLATE HEIGHTMAIN FLOOR OFFICE 121 SF CARPET 9' - 1 1/8" .MAIN FLOOR PORCH 164 SF CONCRETE 9' - 1 1/8" .MAIN FLOOR GARAGE 663 SF CONCRETE 10' - 9 3/8"MAIN FLOOR CLOSET 43 SF VINYL 9' - 1 1/8" .MAIN FLOOR POWDER 27 SF VINYL 9' - 1 1/8" .MAIN FLOOR MUD RM. 79 SF VINYL 9' - 1 1/8" .MAIN FLOOR DINING 177 SF WOOD 9' - 1 1/8" .MAIN FLOOR KITCHEN 384 SF WOOD 9' - 1 1/8" .MAIN FLOOR FOYER 153 SF WOOD 9' - 1 1/8" .UPPER FLOOR PRIMARY SUITE 246 SF CARPET 8' - 1 1/8" VAULTEDUPPER FLOOR BEDROOM #3 139 SF CARPET 8' - 1 1/8" .UPPER FLOOR HALL 143 SF CARPET 8' - 1 1/8"UPPER FLOOR BEDROOM #4 168 SF CARPET 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 175 SF CARPET 8' - 1 1/8" .UPPER FLOOR PRIMARY CLOSET 78 SF CARPET 8' - 1 1/8" .UPPER FLOOR CLOSET 27 SF CARPET 8' - 1 1/8" .UPPER FLOOR CLOSET 29 SF CARPET 8' - 1 1/8" .UPPER FLOOR STORAGE 20 SF CARPET 8' - 1 1/8" .UPPER FLOOR CLOSET 21 SF CARPET 8' - 1 1/8"UPPER FLOOR EN SUITE 140 SF TILE 8' - 1 1/8" .UPPER FLOOR LAUNDRY 55 SF TILE 8' - 1 1/8" .UPPER FLOOR BATH 48 SF VINYL 8' - 1 1/8" .UPPER FLOOR BATH 56 SF VINYL 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE Rough Width Rough Height COUNT COMMENTS1 2/4 x 6/8 2' - 6" 6' - 11" 132 2/4 x 6/8 ARCH 13 2/4 x 6/8 PKT 4' - 10" 6' - 11" 34 2/6 x 6/8 2' - 8" 6' - 11" 45 2/6 x 6/8 PKT 5' - 2" 6' - 11" 16 2/8 x 6/8 2' - 10" 6' - 11" 47 2/8 x 6/8 2' - 10" 6' - 10 1/4" 18 3/0 x 6/8 ARCH 19 3/0 x 6/8 W/ 2-12" D.S. S.L.'S STEEL 110 5/0 x 6/8 FULL VIEW 5' - 2" 6' - 11" 111 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 212 8' x 8' O.H. GARAGE DOOR 113 16' x 8' O.H. GARAGE DOOR 1
FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP. FASTENKING STUD TO HEADERW/ 6-16d SINKERS.MIN. 7/16" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).FRONT ELEVATIONMIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 7/16" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INFRAMING (STUDS AND SILLS) AS SHOWN TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALEXTENT OF HEADER WITH DOUBLE PORTAL FRAMES (TWO BRACED WALL PANELS)BRACED WALL LINECONTINUOUSLYSHEATHED WITH WOODSTRUCTURAL PANELS.OVERLAP0' - 9 1/4" MIN.WOOD STRUCTURAL PANEL SHEATHINGCONTINUOUS OVER BAND OR RIM JOISTNAIL SOLE PLATE TO JOISTPER TABLE R602.3(1)WOOD STRUCTURAL PANEL SHEATHING OVER APPROVED BAND OR RIM JOISTATTACH SHEATHING TOBAND OR RIM JOIST WITH8d COMMON NAILS @3" O.C. TOP @ BOTTOMFASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:11/7/2023 4:49:52 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-502OTT40710.18.23 CB16111539119111.7.23 CB10.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKE3/8" = 1'-0"A-5021METHOD CS-PF - RAISED WOOD W/ OVERLAP3/8" = 1'-0"A-5022METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:
=3x4 =3x4
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
31
32123456789101112131415
ST1 W1W1
B1
T1
BL2
BL10-1-80-1-817-11-8
17-11-81-6-01-6-0Scale = 1:32.4
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.07 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.02 Vert(TL)n/a -n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.02 Horiz(TL)0.00 16 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-R Weight: 64 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 17-11-8.
(lb) -Max Grav All reactions 250 (lb) or less at joint(s) 16, 17, 18, 19, 20, 21,
22, 23, 24, 25, 26, 27, 28, 29, 30
1 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1)All plates are 1.5x3 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4)Gable studs spaced at 1-4-0 oc.5)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F1 1 1Floor Supported Gable Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:40 Page: 1
ID:8WjeWFcE_HLWWDxFLQsyGhziJEK-UTFjWFBVFHxjMhDB?qXSeZ9rL5C36WJjdjwcqbyLzY5
=2x6
=6x12
=M18AHS 7x18
=M18AHS 7x18=1.5x5
=6x8
=6x12 =1.5x5
=6x12
=7x8
=8x10
=6x12 =2x6
=1.5x3
13
12 11 10
9
14
151234561678
W2W1
B1B1
T1T1
W3W3 BL2
BL10-1-80-1-82-4-0
2-4-0
2-5-4
2-8-8
17-11-8
15-3-0
15-3-01-6-01-6-0Scale = 1:32.4
Plate Offsets (X, Y):[3:0-3-0,Edge], [5:0-3-0,Edge], [7:0-3-0,Edge], [8:0-3-0,Edge], [10:0-3-0,Edge], [12:0-8-12,Edge], [15:0-1-8,0-0-9]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.79 Vert(LL)-0.10 11-12 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.67 Vert(CT)-0.46 11-12 >462 240 M18AHS 142/136
BCLL 0.0 Rep Stress Incr NO WB 0.64 Horz(CT)0.08 9 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 144 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 1650F 1.5E(flat)
BOT CHORD 2x4 DF 2400F 2.0E or 2x4 SP 2400F 2.0E(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-1-1 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)9=2480/0-5-8, (min. 0-1-11), 13=2444/0-5-8, (min. 0-1-10)
2 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-8733/0, 3-4=-8733/0, 4-5=-11350/0, 5-6=-11350/0, 6-16=-5084/0, 7-16=-5084/0
BOT CHORD 12-13=0/4696, 11-12=0/11297, 10-11=0/9004, 9-10=0/4544
WEBS 7-10=0/2156, 2-13=-5218/0, 2-12=0/4513, 3-12=-686/0, 4-12=-2867/0, 5-11=-1168/0, 6-11=0/2623, 6-10=-4420/0,7-9=-5107/0
NOTES
1)All plates are MT20 plates unless otherwise indicated.
2)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
3)Load case(s) 1 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 9-13=-10, 1-3=-110, 3-16=-470, 8-16=-110
Job Truss Truss Type Qty Ply Roof
325790-A F2 1 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:40 Page: 1
ID:ovYuJcaP8sQA6W3d1DIjVZziJD4-UTFjWFBVFHxjMhDB?qXSeZ9g552u6NkjdjwcqbyLzY5
=1.5x3 =1.5x3
=3x6
=4x8
=4x8 =1.5x3
=3x4 =1.5x3
=3x6
=3x4
=4x4
=4x6
=3x8 =1.5x3
=1.5x3
13
12 11 10
9
14
15
1 2 3 4 5 6 7 8
W2W1
B1
T1
W3 BL2
BL10-1-82-5-8 0-1-82-5-4
17-11-8
17-11-81-6-01-6-0Scale = 1:32.4
Plate Offsets (X, Y):[7:0-1-8,Edge], [10:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.60 Vert(LL)-0.20 11-12 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.72 Vert(CT)-0.31 11-12 >684 240
BCLL 0.0 Rep Stress Incr NO WB 0.42 Horz(CT)0.07 9 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 71 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF 1650F 1.5E(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)9=1056/0-5-8, (min. 0-1-8), 13=1056/0-5-8, (min. 0-1-8)
3 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2841/0, 3-4=-2841/0, 4-5=-3403/0, 5-6=-3403/0, 6-7=-1799/0
BOT CHORD 12-13=0/1727, 11-12=0/3375, 10-11=0/2841, 9-10=0/1799
WEBS 2-13=-1954/0, 2-12=0/1271, 3-12=-264/0, 4-12=-609/0, 5-11=-275/0, 6-11=0/641, 6-10=-1189/0, 7-10=0/615, 7-9=-2021/0
NOTES
1)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
2)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F3 1 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:41 Page: 1
ID:ovYuJcaP8sQA6W3d1DIjVZziJD4-yfp6jaC70b4azroNZX2hBnhuuVNKrtPtsNg9M1yLzY4
=1.5x3 =1.5x3
=3x6
=4x8
=4x8 =1.5x3
=3x4 =1.5x3
=3x6
=3x4 =1.5x3
=4x12
=4x10
=1.5x3
=2x6
13
12 11 10
9
14 15
16
1 2 3 4 5 6 7 8
W2W1 BL2BL2T1
B1
W3
BL10-1-82-4-0 0-3-02-5-4
0-3-0
17-11-8
17-8-8
17-8-81-6-00-9-40-9-40-8-121-6-0Scale = 1:33.3
Plate Offsets (X, Y):[8:0-4-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.48 Vert(LL)-0.21 11-12 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.96 Vert(CT)-0.32 11-12 >671 240
BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(CT)0.05 16 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 71 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:2-2-0 oc bracing: 11-12.
REACTIONS (lb/size)13=1052/0-5-8, (min. 0-1-8), 16=1044/0-3-0, (min. 0-1-8)
4 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2828/0, 3-4=-2828/0, 4-5=-3375/0, 5-6=-3375/0, 6-7=-1747/0, 7-8=-1747/0
BOT CHORD 12-13=0/1720, 11-12=0/3354, 10-11=0/2809
WEBS 2-13=-1946/0, 2-12=0/1264, 3-12=-264/0, 4-12=-601/0, 5-11=-274/0, 6-11=0/645, 6-10=-1212/0, 7-10=-284/0,8-10=0/1864, 8-16=-1080/0
NOTES
1)Bearing at joint(s) 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
2)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
3)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outerends or restrained by other means.
4)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F4 3 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:41 Page: 1
ID:FMji9GKENoLKg?B?ddLAXjziJ8F-yfp6jaC70b4azroNZX2hBnhwlVJXrrjtsNg9M1yLzY4
MT18HS 3x12 FP
3x8 FP
=1.5x3 =1.5x3
=4x8
=4x12
=4x12 =1.5x3 =3x6
=3x8 =1.5x3
=1.5x5
=3x4 =1.5x3
=3x8
=3x6
=3x4
=3x4
=5x8
=5x8 =6x6
=5x8 =1.5x3
=1.5x3
21
20 19 18 17 16 15 14
13
22
23123456789101112
W1 W2 W5W5
T1
B1 B2
T2
W3 W4 BL2
BL10-1-80-11-141-10-122-2-4 0-3-80-1-80-11-14
2-5-4
0-1-12
17-10-0
0-1-12
17-11-12
1-4-6
21-7-6
2-3-4
20-3-0
17-8-4
17-8-41-6-01-6-0Scale = 1:37.9
Plate Offsets (X, Y):[10:0-3-0,Edge], [13:Edge,0-1-8], [14:0-3-0,Edge], [21:Edge,0-1-8], [22:0-1-8,0-0-2]
Loading (psf)Spacing 1-7-3 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.92 Vert(LL)-0.43 17-19 >596 480 MT18HS 220/190
TCDL 15.0 Lumber DOL 1.00 BC 1.00 Vert(CT)-0.65 17-19 >395 240 MT20 197/144
BCLL 0.0 Rep Stress Incr NO WB 0.69 Horz(CT)0.11 13 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 104 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 1650F 1.5E(flat) *Except* T2:2x4 DF 2400F 2.0E or 2x4 SP
2400F 2.0E(flat)
BOT CHORD 2x4 DF 2400F 2.0E or 2x4 SP 2400F 2.0E(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-8-11 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)13=2586/0-2-10, (min. 0-1-12), 21=1276/0-5-8, (min. 0-1-8)
5 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3858/0, 3-4=-3858/0, 4-5=-5868/0, 5-6=-5868/0, 6-7=-6188/0, 7-8=-6188/0, 8-9=-6188/0, 9-10=-5467/0,
10-11=-2200/0
BOT CHORD 20-21=0/2185, 19-20=0/5069, 18-19=0/6215, 17-18=0/6215, 16-17=0/5467, 15-16=0/5467, 14-15=0/5467, 13-14=0/2072
WEBS 9-16=-596/0, 10-15=0/718, 11-14=0/2199, 2-21=-2475/0, 2-20=0/1909, 4-20=-1382/0, 4-19=0/913, 6-19=-522/0,
6-17=-64/410, 8-17=-306/0, 9-17=-62/880, 10-14=-3882/0, 11-13=-3209/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)The Fabrication Tolerance at joint 18 = 11%
4)Provide mechanical connection (by others) of truss to bearing plate at joint(s) 13.
5)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6)Load case(s) 1 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
7)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
8)CAUTION, Do not erect truss backwards.
9)In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 15-21=-8, 13-15=-98 (F=-90), 1-10=-88, 10-12=-178 (F=-90)
Concentrated Loads (lb)
Vert: 9=-610, 10=-610
Job Truss Truss Type Qty Ply Roof
325790-A F5 1 1Floor Girder Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:41 Page: 1
ID:aHKUEUpSvgNE3chhtsdZZozcgB6-yfp6jaC70b4azroNZX2hBnhptVJzrp9tsNg9M1yLzY4
MT18HS 3x12 FP
3x6 FP
=1.5x3 =1.5x3
=4x8
=4x10
=4x12 =1.5x3 =3x4
=3x6 =1.5x3 =3x4 =1.5x3
=4x10
=4x8
=5x5 =4x4
=4x6 =1.5x3
=1.5x3
18
17 16 15 14 13
12
19
201234567891011
W2W1
T1
B1 B2
T2
W3 BL2
BL10-1-81-1-60-1-82-5-4
21-7-6
21-7-61-6-01-6-0Scale = 1:37.9
Plate Offsets (X, Y):[10:0-1-8,Edge], [12:Edge,0-1-8], [13:0-1-8,Edge], [18:Edge,0-1-8], [19:0-1-8,0-0-2]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.88 Vert(LL)-0.40 14-16 >633 480 MT18HS 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.93 Vert(CT)-0.62 14-16 >416 240 MT20 197/144
BCLL 0.0 Rep Stress Incr YES WB 0.50 Horz(CT)0.11 12 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 86 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF 1650F 1.5E(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:2-2-0 oc bracing: 14-16.
REACTIONS (lb/size)12=1275/0-2-10, (min. 0-1-8), 18=1275/0-5-8, (min. 0-1-8)
6 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3647/0, 3-4=-3647/0, 4-5=-5001/0, 5-6=-5001/0, 6-7=-4185/0, 7-8=-4185/0, 8-9=-4185/0, 9-10=-1183/0
BOT CHORD 17-18=0/2135, 16-17=0/4578, 15-16=0/4846, 14-15=0/4846, 13-14=0/2940, 12-13=0/1183
WEBS 2-18=-2417/0, 2-17=0/1725, 3-17=-263/0, 4-17=-1063/0, 4-16=0/483, 5-16=-271/0, 6-14=-754/0, 8-14=-271/0,9-14=0/1421, 9-13=-2005/0, 10-13=0/1009, 10-12=-1718/0
NOTES
1)All plates are MT20 plates unless otherwise indicated.
2)Provide mechanical connection (by others) of truss to bearing plate at joint(s) 12.
3)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F6 4 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:42 Page: 1
ID:iBc3WBDPT0RfsBobFfwrwJziIr0-QrNUxwCmnvCRb?Na7FZwj_E?HvgHaJQ051PjuTyLzY3
=6x6
=5x8 =1.5x3
=4x8
=4x8 =1.5x3
=3x4
=1.5x3
=3x6
=3x4
=4x4
=4x6
=3x8 =3x4
15 14 13 12 11
10
16
1 2 3 4 5 6 7 8 9
W2 W3W1W1BL1BL1
T1
B1
W40-3-141-0-72-5-01-0-72-5-4
1-0-5
1-4-3
0-3-14
0-3-14
3-7-3
4-11-6
12-8-12
17-8-21-6-00-6-00-6-01-0-01-6-01-6-0Scale = 1:34.2
Plate Offsets (X, Y):[8:0-1-8,Edge], [11:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.48 Vert(LL)-0.19 12-13 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.95 Vert(CT)-0.31 12-13 >683 240
BCLL 0.0 Rep Stress Incr YES WB 0.40 Horz(CT)0.06 10 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 73 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:2-2-0 oc bracing: 12-13.
REACTIONS (lb/size)10=1046/0-5-8, (min. 0-1-8), 16=1044/0-3-6, (min. 0-1-8)
7 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-873/0, 2-3=-873/0, 3-4=-2699/0, 4-5=-2699/0, 5-6=-3308/0, 6-7=-3308/0, 7-8=-1745/0, 1-16=-1044/0
BOT CHORD 13-14=0/1557, 12-13=0/3252, 11-12=0/2765, 10-11=0/1745
WEBS 4-13=-281/0, 1-14=0/1313, 3-13=0/1304, 3-14=-1095/0, 5-13=-630/0, 6-12=-278/0, 7-12=0/620, 7-11=-1164/0,8-11=0/602, 8-10=-1973/0
NOTES
1)Bearing at joint(s) 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
2)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
3)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outerends or restrained by other means.
4)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F7 1 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:42 Page: 1
ID:EbIGoDzH9Tq2uQlxC_zmp_ziIku-QrNUxwCmnvCRb?Na7FZwj_E5XvgzaKu051PjuTyLzY3
=6x6
=5x8 =1.5x3
=4x8
=4x8 =1.5x3
=3x4
=1.5x3
=3x6
=3x4
=4x4
=4x6 =3x4
=4x10
=3x4
=2x6
=3x6
17 16 15 14 13
12
1119
181234567820910
W2 W3W1W1 BL2BL2BL1BL1
T1
B1
W4 W50-3-140-3-01-0-72-5-01-0-71-5-9
2-5-4
0-2-12
17-8-2
1-0-5
1-4-3
0-3-14
0-3-14
1-10-1
19-6-3
3-7-3
4-11-6
12-6-0
17-5-61-6-00-6-00-6-01-0-01-6-01-6-0Scale = 1:37
Plate Offsets (X, Y):[8:0-1-8,Edge], [10:0-1-8,Edge], [13:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.52 Vert(LL)-0.19 14-15 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 1.00 Vert(CT)-0.29 14-15 >718 240
BCLL 0.0 Rep Stress Incr NO WB 0.40 Horz(CT)0.05 12 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 83 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:6-0-0 oc bracing: 11-12.
REACTIONS (lb/size)12=1497/0-5-8, (min. 0-1-8), 19=1012/0-3-6, (min. 0-1-8)
Max Grav 12=1497 (LC 1), 19=1018 (LC 3)
8 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-850/0, 2-3=-850/0, 3-4=-2609/0, 4-5=-2609/0, 5-6=-3123/0, 6-7=-3123/0, 7-8=-1456/0, 8-20=0/364, 9-20=0/364,
9-10=0/361, 1-19=-1018/0
BOT CHORD 15-16=0/1513, 14-15=0/3115, 13-14=0/2536, 12-13=0/1456
WEBS 4-15=-281/0, 9-12=-272/0, 1-16=0/1278, 3-15=0/1251, 3-16=-1062/0, 5-15=-577/0, 6-14=-275/0, 7-14=0/682,
7-13=-1248/0, 8-13=0/638, 8-12=-1959/0, 10-12=-467/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Bearing at joint(s) 19 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
3)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
4)Load case(s) 1 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
6)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 11-17=-10, 1-10=-110
Concentrated Loads (lb)
Vert: 10=-220
Job Truss Truss Type Qty Ply Roof
325790-A F8 1 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:43 Page: 1
ID:d93PVlWiwotK9cERRjEjj_ziIgI-QrNUxwCmnvCRb?Na7FZwj_E4tvf7aKx051PjuTyLzY3
=6x8
=6x8 =1.5x3
=4x10
=4x10 =1.5x3
=3x4
=1.5x3
=3x6
=3x6
=4x4
=4x6
=4x8 =1.5x3
=1.5x3
15 14 13 12 11
10
17
16123456789
W3W2W1W1BL1BL1
T1
B1
W4 BL20-3-141-0-72-5-0 0-1-81-0-72-5-4
1-0-5
1-4-3
0-3-14
0-3-14
3-7-3
4-11-6
12-8-12
17-8-21-6-00-6-00-6-01-0-01-6-01-6-0Scale = 1:34.2
Plate Offsets (X, Y):[1:Edge,0-1-8], [8:0-1-8,Edge], [10:Edge,0-1-8], [11:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.85 Vert(LL)-0.19 12-13 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.87 Vert(CT)-0.37 12-13 >571 240
BCLL 0.0 Rep Stress Incr NO WB 0.50 Horz(CT)0.07 10 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 73 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF 1650F 1.5E(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-11-7 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)10=1298/0-5-8, (min. 0-1-8), 17=1305/0-3-6, (min. 0-1-8)
9 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1090/0, 2-3=-1090/0, 3-4=-3372/0, 4-5=-3372/0, 5-6=-4131/0, 6-7=-4131/0, 7-8=-2177/0, 1-17=-1305/0
BOT CHORD 13-14=0/1947, 12-13=0/4068, 11-12=0/3460, 10-11=0/2177
WEBS 4-13=-357/0, 1-14=0/1640, 3-13=0/1625, 3-14=-1373/0, 5-13=-795/0, 6-12=-352/0, 7-12=0/765, 7-11=-1465/0,8-11=0/747, 8-10=-2454/0
NOTES
1)Bearing at joint(s) 17 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
2)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
3)Load case(s) 1 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 10-15=-10, 1-9=-140
Job Truss Truss Type Qty Ply Roof
325790-A F9 7 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:43 Page: 1
ID:KxMm_AT87gKVeWsIVeFwK2ziImp-u2xs8GDOYCKID9xmhy49GCnATJ1PJmc9Kh9GQvyLzY2
3x8 FP
MT18HS 3x12 FP
=1.5x3 =1.5x3
=4x8
=5x12
=5x16 =1.5x3 =3x6
=3x8 =1.5x3 =3x4 =1.5x3
=4x10
=4x8
=5x5
=5x8
=4x8 =1.5x3
=1.5x3
18
17 16 15 14 13
12
19 201234567891011
W3W1W2W2BL1 BL1
B1
T1 T2
B2
W40-1-82-5-0 0-1-82-5-4
22-11-0
22-11-01-6-01-6-0Scale = 1:39.8
Plate Offsets (X, Y):[10:0-1-8,Edge], [12:Edge,0-1-8], [13:0-1-8,Edge], [18:Edge,0-1-8]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.96 Vert(LL)-0.39 15-16 >695 480 MT18HS 220/190
TCDL 15.0 Lumber DOL 1.00 BC 0.77 Vert(CT)-0.73 15-16 >372 240 MT20 197/144
BCLL 0.0 Rep Stress Incr NO WB 0.67 Horz(CT)0.13 12 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 107 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 DF 2400F 2.0E or 2x4 SP 2400F 2.0E(flat) *Except* T2:2x4 SPF
1650F 1.5E(flat)
BOT CHORD 2x4 DF 2400F 2.0E or 2x4 SP 2400F 2.0E(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-4-9 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)12=1674/0-5-8, (min. 0-1-8), 18=1558/0-5-8, (min. 0-1-8)
10 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4693/0, 3-4=-4693/0, 4-5=-6806/0, 5-6=-6806/0, 6-7=-6201/0, 7-8=-6201/0, 8-9=-6201/0, 9-10=-2886/0
BOT CHORD 17-18=0/2599, 16-17=0/6075, 15-16=0/6825, 14-15=0/4853, 13-14=0/4853, 12-13=0/2886
WEBS 2-18=-2963/0, 2-17=0/2375, 3-17=-305/0, 4-17=-1577/0, 4-16=0/834, 5-16=-345/0, 6-15=-712/0, 8-15=-348/0,
9-15=0/1538, 9-13=-2245/0, 10-13=0/1123, 10-12=-3256/0
NOTES
1)All plates are MT20 plates unless otherwise indicated.
2)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
3)Load case(s) 1 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 12-18=-10, 1-3=-110, 3-11=-140
Job Truss Truss Type Qty Ply Roof
325790-A F10 4 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:43 Page: 1
ID:qvI68uM2q6SapFdE?L2zWRziIj4-u2xs8GDOYCKID9xmhy49GCn8lJ2yJjy9Kh9GQvyLzY2
MT18HS 3x12 FP
3x6 FP
=4x8
=4x10
=4x12
=3x4
=3x6
=3x4
=4x10
=4x8
=5x5
=6x6 =3x4
=4x10
=3x4
20 19 18 17 16 15
14
13
22
21 23123456789101112
W2W1
T1
B2B1
T2
W3 W4BL1 BL20-1-80-1-82-5-0
1-9-02-5-4
0-1-8
24-11-0
0-2-12
22-11-0
1-10-8
24-9-8
22-8-4
22-8-41-6-01-6-0Scale = 1:42.8
Plate Offsets (X, Y):[10:0-1-8,Edge], [12:0-1-8,Edge], [15:0-1-8,Edge], [20:Edge,0-1-8]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.98 Vert(LL)-0.44 16-18 >618 480 MT18HS 220/190
TCDL 15.0 Lumber DOL 1.00 BC 0.62 Vert(CT)-0.65 16-18 >419 360 MT20 197/144
BCLL 0.0 Rep Stress Incr NO WB 0.53 Horz(CT)0.10 14 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 109 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 1650F 1.5E(flat) *Except* T2:2x4 SPF No.2(flat)
BOT CHORD 2x4 DF 2400F 2.0E or 2x4 SP 2400F 2.0E(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)14=1842/0-5-8, (min. 0-1-8), 20=1323/0-5-8, (min. 0-1-8)
Max Grav 14=1842 (LC 1), 20=1330 (LC 3)
11 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3847/0, 3-4=-3847/0, 4-5=-5400/0, 5-6=-5400/0, 6-7=-4784/0, 7-8=-4784/0, 8-9=-4784/0, 9-10=-1990/0,
10-11=0/445, 11-12=0/443
BOT CHORD 19-20=0/2238, 18-19=0/4881, 17-18=0/5348, 16-17=0/5348, 15-16=0/3637, 14-15=0/1990
WEBS 11-14=-290/0, 2-20=-2534/0, 2-19=0/1836, 3-19=-261/0, 4-19=-1180/0, 4-18=0/592, 5-18=-267/0, 6-16=-657/0,
8-16=-270/0, 9-16=0/1323, 9-15=-1899/0, 10-15=0/949, 10-14=-2617/0, 12-14=-542/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)All plates are 1.5x3 MT20 unless otherwise indicated.
4)The Fabrication Tolerance at joint 17 = 11%
5)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6)Load case(s) 1 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
7)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
8)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 13-20=-10, 1-12=-110
Concentrated Loads (lb)
Vert: 12=-220
Job Truss Truss Type Qty Ply Roof
325790-A F11 3 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:44 Page: 1
ID:t2JDwKHfmL8l3upJQgLj5ZziIe1-MEVEMcE0JWS9qJWyEgbOoPJJDiRc2CLJYLuqzMyLzY1
MT18HS 3x12 FP
3x6 FP=1.5x3 =1.5x3
=4x8
=4x10
=4x12 =1.5x3 =3x4
=3x6 =1.5x3
=1.5x3
=3x4 =1.5x3
=4x8
=4x8
=5x5
=6x6
=4x8 =1.5x3
=1.5x3
18 17 16 15 14 13 12
19 201234567891011
W2W1BL1 BL1
T1
B1 B2
T2
W30-1-82-5-0 0-1-82-5-4
22-11-0
22-11-01-6-01-6-0Scale = 1:39.8
Plate Offsets (X, Y):[10:0-1-8,Edge], [12:Edge,0-1-8], [13:0-1-8,Edge], [18:Edge,0-1-8]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.75 Vert(LL)-0.44 14-16 >622 480 MT18HS 220/190
TCDL 15.0 Lumber DOL 1.00 BC 0.64 Vert(CT)-0.67 14-16 >408 360 MT20 197/144
BCLL 0.0 Rep Stress Incr NO WB 0.54 Horz(CT)0.10 12 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 99 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 1650F 1.5E(flat)
BOT CHORD 2x4 DF 2400F 2.0E or 2x4 SP 2400F 2.0E(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-7-1 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)12=1353/0-5-8, (min. 0-1-8), 18=1353/0-5-8, (min. 0-1-8)
12 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3932/0, 3-4=-3932/0, 4-5=-5569/0, 5-6=-5569/0, 6-7=-5038/0, 7-8=-5038/0, 8-9=-5038/0, 9-10=-2336/0
BOT CHORD 17-18=0/2281, 16-17=0/5008, 15-16=0/5559, 14-15=0/5559, 13-14=0/3930, 12-13=0/2336
WEBS 2-18=-2582/0, 2-17=0/1884, 3-17=-260/0, 4-17=-1228/0, 4-16=0/640, 5-16=-267/0, 6-14=-594/0, 8-14=-272/0,9-14=0/1264, 9-13=-1820/0, 10-13=0/918, 10-12=-2636/0
NOTES
1)All plates are MT20 plates unless otherwise indicated.
2)All plates are 1.5x3 MT20 unless otherwise indicated.
3)The Fabrication Tolerance at joint 15 = 11%
4)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F12 1 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:44 Page: 1
ID:t2JDwKHfmL8l3upJQgLj5ZziIe1-MEVEMcE0JWS9qJWyEgbOoPJNqiQF2CHJYLuqzMyLzY1
3x6 FP
3x6 FP
=3x4 =3x4 =3x4
37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20
38 3912345678910111213141516171819
ST1W1 W1BL1BL1
T1
B1 B2
T20-1-80-1-822-11-0
22-11-01-6-01-6-0Scale = 1:39.8
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.09 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.01 Vert(TL)n/a -n/a 999
BCLL 0.0 Rep Stress Incr NO WB 0.02 Horiz(TL)0.00 20 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-R Weight: 80 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 22-11-0.
(lb) -Max Grav All reactions 250 (lb) or less at joint(s) 20, 21, 22, 23, 24, 25,
26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37
13 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1)All plates are 1.5x3 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4)Gable studs spaced at 1-4-0 oc.5)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F13 1 1Floor Supported Gable Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:45 Page: 1
ID:VXYUpVKkQnu?Ic4kBbspJiziIa5-MEVEMcE0JWS9qJWyEgbOoPJX3ia22KJJYLuqzMyLzY1
=1.5x3
=1.5x3
=1.5x3
=3x4
=3x6 =3x4
=3x4
=3x4
=3x4
=3x4 =1.5x3
9
8
7
6
10
11
1 2 12 3 4 5
W1 W4
T1
B1
W3W2BL10-1-82-5-0
1-9-0
2-5-4
0-1-8
0-1-8
0-2-12
2-2-12
0-1-8
9-11-0
1-10-8
2-0-0
2-6-0
4-8-12
5-0-12
9-9-81-6-01-6-0Scale = 1:25.5
Plate Offsets (X, Y):[3:0-1-8,Edge], [7:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.60 Vert(LL)-0.01 6-7 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.27 Vert(CT)-0.07 6-7 >999 240
BCLL 0.0 Rep Stress Incr NO WB 0.18 Horz(CT)0.00 5 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 42 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size)5=342/0-1-8, (min. 0-1-8), 8=1273/0-5-8, (min. 0-1-8)
Max Grav 5=362 (LC 4), 8=1273 (LC 1)
14 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 5-6=0/253, 1-2=0/579, 2-12=0/582, 3-12=0/582, 3-4=-279/204
BOT CHORD 7-8=-204/279, 6-7=-20/421
WEBS 2-8=-454/0, 1-8=-708/0, 3-8=-867/0, 4-6=-480/23
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5.
3)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
4)Load case(s) 1 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outerends or restrained by other means.
6)Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in.
7)CAUTION, Do not erect truss backwards.
8)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 220 lb down at 0-2-4 on top chord. The design/selection of such
connection device(s) is the responsibility of others.
9)In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 6-9=-10, 1-12=-220 (F=-110), 5-12=-110
Concentrated Loads (lb)
Vert: 1=-220 (F)
Job Truss Truss Type Qty Ply Roof
325790-A F14 1 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:45 Page: 1
ID:0_Lzm5HngM3CzOWC9XJeqZziIbR-rQ3cZyFe4qa0SS58oN6dLdsao6sFnlASn_eNVoyLzY0
=3x4
20 19 18 17 16 15 14 13 12
11
21
1 2 3 4 5 6 7 8 9 10
ST1W1 W1
B1
T1
BL10-1-811-11-0
11-11-01-6-01-6-0Scale = 1:23.4
Loading (psf)Spacing 1-7-3 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.06 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.01 Vert(TL)n/a -n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.02 Horiz(TL)0.00 11 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-R Weight: 43 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 11-11-0.
(lb) -Max Grav All reactions 250 (lb) or less at joint(s) 11, 12, 13, 14, 15, 16,
17, 18, 19, 20
15 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1)All plates are 1.5x3 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4)Gable studs spaced at 1-4-0 oc.5)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
7)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F15 1 1Floor Supported Gable Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:45 Page: 1
ID:5nFHsd_gjOJGPxaIqQWJiszcgJw-rQ3cZyFe4qa0SS58oN6dLdsjN6wKnnfSn_eNVoyLzY0
=1.5x3 =1.5x3
=3x6
=3x4
=3x4 =1.5x3 =1.5x3
=3x4
=3x4
=3x4
=4x4 =6x6
=3x6
11
10 9 8
13
14
12 7123456
W2W1 BL2BL2BL2
T1
B1
W3
T2
W4BL1 0-4-80-1-81-10-8
2-0-6
2-5-4
0-4-8
12-2-10
4-7-14
11-10-2
7-2-4
7-2-41-6-00-6-00-6-01-0-01-6-0Scale = 1:25.1
Plate Offsets (X, Y):[8:Edge,0-1-8], [9:0-1-8,Edge], [10:0-1-8,Edge], [14:0-3-0,0-3-0]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.52 Vert(LL)-0.14 10-11 >992 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.59 Vert(CT)-0.22 10-11 >645 240
BCLL 0.0 Rep Stress Incr YES WB 0.25 Horz(CT)0.02 14 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 51 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)11=705/0-5-8, (min. 0-1-8), 14=686/0-3-6, (min. 0-1-8)
16 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 8-14=0/584, 7-14=0/584, 2-3=-1533/0, 3-4=-1533/0, 4-5=-1533/0
BOT CHORD 10-11=0/1076, 9-10=0/1533, 8-9=0/984
WEBS 4-9=-263/0, 2-11=-1216/0, 2-10=0/603, 5-9=0/676, 5-8=-1028/0, 7-14=-718/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Bearing at joint(s) 14 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
3)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F16 7 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:46 Page: 1
ID:yCDn_Rds1_2Zj5lsERIaAVziJ99-rQ3cZyFe4qa0SS58oN6dLdsbB6nGnk1Sn_eNVoyLzY0
=3x4 =3x4
13 12 11 10 9 8
14
1 2 3 4 5 6 7
ST1W1 W1
B1
T1
BL1 0-1-86-11-8
6-11-81-6-01-6-0Scale = 1:16
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.08 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.02 Vert(TL)n/a -n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.02 Horiz(TL)0.00 8 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-R Weight: 27 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 6-11-8.
(lb) -Max Grav All reactions 250 (lb) or less at joint(s) 8, 9, 10, 11, 12, 13
17 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1)All plates are 1.5x3 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4)Gable studs spaced at 1-4-0 oc.
5)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
7)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F17 1 1Floor Supported Gable Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:46 Page: 1
ID:A7huA36Ww4lWheXnmcYjTeziJ9p-Jdd?mIFGr7it4cgLM4esuqPtnWGPWEoc0eNw1EyLzY?
=1.5x3 =1.5x3
=3x6
=3x4
=3x4
=3x6
=4x6
5 4
7
8
6
1 2 3
BL2BL2BL2W1
T1
B1
W2 W3BL10-1-82-0-6 0-4-82-5-4
0-4-8
5-2-10
4-10-2
4-10-21-6-00-6-00-6-01-0-01-6-0Scale = 1:24.1
Plate Offsets (X, Y):[8:0-3-0,0-3-4]
Loading (psf)Spacing 1-7-3 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.25 Vert(LL)0.00 4 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.20 Vert(CT)-0.06 4-5 >943 240
BCLL 0.0 Rep Stress Incr YES WB 0.05 Horz(CT)0.00 8 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-P Weight: 24 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-2-10 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)5=228/0-5-8, (min. 0-1-8), 8=213/0-3-6, (min. 0-1-8)
18 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5=-256/0
NOTES
1)Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
2)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
3)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outerends or restrained by other means.
4)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F18 1 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:46 Page: 1
ID:loE43sBqsJEREvUGVen_4EzcgH4-Jdd?mIFGr7it4cgLM4esuqPr7WDhWELc0eNw1EyLzY?
=3x4 =3x4
22 21 20 19 18 17 16 15 14 13 12
23 24
1 2 3 4 5 6 7 8 9 10 11
ST1W1 W1BL1BL1
B1
T10-1-80-1-812-7-0
12-7-01-6-01-6-0Scale = 1:24.4
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.07 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.02 Vert(TL)n/a -n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.02 Horiz(TL)0.00 12 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-R Weight: 47 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 12-7-0.
(lb) -Max Grav All reactions 250 (lb) or less at joint(s) 12, 13, 14, 15, 16, 17,
18, 19, 20, 21, 22
19 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1)All plates are 1.5x3 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4)Gable studs spaced at 1-4-0 oc.5)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F19 1 1Floor Supported Gable Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:47 Page: 1
ID:dDDaBfq0AuzkZ3frufZFYtziJ6J-Jdd?mIFGr7it4cgLM4esuqPtqWGRWEoc0eNw1EyLzY?
=1.5x3 =1.5x3
=3x6
=3x4
=3x4
=3x4
=3x6 =1.5x3
=3x4
=3x6 =1.5x3
=1.5x3
10
9 8
7
11 12
1 2 3 4 5 6
W3W1BL1 BL1
B1
T1
W20-1-82-5-4 0-1-82-1-8
12-7-8
12-7-81-6-01-6-0Scale = 1:24.4
Plate Offsets (X, Y):[2:0-1-8,Edge], [9:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.34 Vert(LL)-0.06 8-9 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.53 Vert(CT)-0.10 7-8 >999 240
BCLL 0.0 Rep Stress Incr YES WB 0.26 Horz(CT)0.03 7 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 52 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)7=736/0-5-8, (min. 0-1-8), 10=736/0-5-8, (min. 0-1-8)
20 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1067/0, 3-4=-1668/0, 4-5=-1668/0
BOT CHORD 9-10=0/1067, 8-9=0/1616, 7-8=0/1133
WEBS 5-7=-1280/0, 5-8=0/611, 4-8=-266/0, 3-9=-627/0, 2-9=0/341, 2-10=-1236/0
NOTES
1)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
2)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F20 5 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:47 Page: 1
ID:1WNHFtfETbCjtvb84jJz_wziJ6X-npAN_eGubRqkhmFXwo95Q2x_QwTjFdJlEI7UZhyLzY_
=1.5x3 =1.5x3
=4x6 =3x4
=4x4
=3x6 =1.5x3
=3x8
=3x4
=4x8 =1.5x3
=3x8
=3x6 =1.5x3
=1.5x3
13
12 11 10
9
14 15
1 2 3 4 5 6 7 8
W3W1BL1 BL1
B1
T1
W20-1-82-5-4
0-9-6
0-1-816-3-6
16-3-61-6-01-6-0Scale = 1:29.9
Plate Offsets (X, Y):[12:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.39 Vert(LL)-0.14 10-11 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.83 Vert(CT)-0.23 10-11 >851 240
BCLL 0.0 Rep Stress Incr YES WB 0.36 Horz(CT)0.05 9 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 67 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)9=955/0-5-8, (min. 0-1-8), 13=955/0-2-10, (min. 0-1-8)
21 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-681/0, 3-4=-2667/0, 4-5=-2667/0, 5-6=-2472/0, 6-7=-2472/0
BOT CHORD 12-13=0/681, 11-12=0/1930, 10-11=0/2823, 9-10=0/1540
WEBS 7-9=-1742/0, 7-10=0/1064, 6-10=-264/0, 5-10=-400/0, 4-11=-272/0, 3-11=0/841, 3-12=-1425/0, 2-12=0/734, 2-13=-1183/0
NOTES
1)Provide mechanical connection (by others) of truss to bearing plate at joint(s) 13.
2)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
3)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outerends or restrained by other means.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F21 4 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:47 Page: 1
ID:j?BLDdqOShtQU0BOksLpU4ziIqD-npAN_eGubRqkhmFXwo95Q2xzawP3FcqlEI7UZhyLzY_
=3x4
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18
17
331 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ST1W1 W1
B1
T1
BL10-1-819-11-8
19-11-81-6-01-6-0Scale = 1:35.4
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.07 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.01 Vert(TL)n/a -n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.02 Horiz(TL)0.00 17 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-R Weight: 69 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 19-11-8.
(lb) -Max Grav All reactions 250 (lb) or less at joint(s) 17, 18, 19, 20, 21, 22,
23, 24, 25, 26, 27, 28, 29, 30, 31, 32
22 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1)All plates are 1.5x3 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4)Gable studs spaced at 1-4-0 oc.5)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
7)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A F22 1 1Floor Supported Gable Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:48 Page: 1
ID:4bBghZDfxXgqZNrEz9gXXKziJ75-F?klB_HWMlybJwqjTVgKzFUDOKx__8JvTys157yLzXz
=1.5x3 =1.5x3
=6x6
=3x4
=6x6 =3x4
45
6
1 2 3
W1
B1B1
W2
T1
BL1 0-1-81-9-11
4-1-6
4-1-61-6-01-6-0Scale = 1:22.3
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.43 Vert(LL)-0.04 4-5 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.44 Vert(CT)-0.07 4-5 >642 240
BCLL 0.0 Rep Stress Incr NO WB 0.07 Horz(CT)0.00 4 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-P Weight: 24 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-1-6 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)4=570/0-5-8, (min. 0-1-8), 5=570/0-2-10, (min. 0-1-8)
23 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BOT CHORD 4-5=0/365
WEBS 2-5=-426/0, 2-4=-435/0
NOTES
1)Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5.
2)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
3)Load case(s) 1 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
4)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
5)CAUTION, Do not erect truss backwards.6)In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 4-5=-100 (F=-90), 1-3=-200 (F=-90)
Job Truss Truss Type Qty Ply Roof
325790-A F23 1 1Floor Girder Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:48 Page: 1
ID:nEE9Dp27vQTEUOqcbs8FY9ziIof-F?klB_HWMlybJwqjTVgKzFU8nKrO_7VvTys157yLzXz
=3x4 =3x4
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
31 32
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
ST1W1 W1BL1BL1
B1
T10-1-80-1-817-11-8
17-11-81-8-01-8-0Scale = 1:32.4
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.07 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.02 Vert(TL)n/a -n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.02 Horiz(TL)0.00 16 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-R Weight: 68 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 17-11-8.
(lb) -Max Grav All reactions 250 (lb) or less at joint(s) 16, 17, 18, 19, 20, 21,
22, 23, 24, 25, 26, 27, 28, 29, 30
24 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1)All plates are 1.5x3 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4)Gable studs spaced at 1-4-0 oc.5)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A FF1 1 1Floor Supported Gable Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:48 Page: 1
ID:Liasn9dwT7lfMtzqEa?yWXziFwa-F?klB_HWMlybJwqjTVgKzFUDKKxw_8IvTys157yLzXz
=1.5x3 =1.5x3
=3x6
=4x6
=4x8 =1.5x3
=3x4
=1.5x3
=3x6
=3x4
=4x4
=4x4
=3x6 =1.5x3
=1.5x3
13
12 11 10
9
14 1512345678
W2W1BL1 BL1
B1
T1
W30-1-82-5-8 0-1-82-5-4
17-11-8
17-11-81-8-01-8-0Scale = 1:32.4
Plate Offsets (X, Y):[7:0-1-8,Edge], [10:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.42 Vert(LL)-0.17 11-12 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.88 Vert(CT)-0.26 11-12 >818 240
BCLL 0.0 Rep Stress Incr YES WB 0.39 Horz(CT)0.06 9 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 74 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)9=1056/0-5-8, (min. 0-1-8), 13=1056/0-5-8, (min. 0-1-8)
25 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2536/0, 3-4=-2536/0, 4-5=-3037/0, 5-6=-3037/0, 6-7=-1606/0
BOT CHORD 12-13=0/1541, 11-12=0/3011, 10-11=0/2535, 9-10=0/1606
WEBS 2-13=-1793/0, 2-12=0/1169, 3-12=-265/0, 4-12=-559/0, 5-11=-276/0, 6-11=0/590, 6-10=-1092/0, 7-10=0/616, 7-9=-1853/0
NOTES
1)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
2)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A FF2 2 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:49 Page: 1
ID:lHG_QAfpm27DDKhPvjYf8AziFwX-jCI7PJI9724Sx4Pw1DBZVT1Iej4mjVl2iccbdZyLzXy
=1.5x3 =1.5x3
=3x6
=4x6
=4x8 =1.5x3
=3x4
=1.5x3
=3x6
=3x4
=1.5x3
=5x12
=5x8
=3x413
12 11 10 9 15
141 2 3 4 5 6 7 8
W2W1 BL2BL2
T1
B1
W3BL10-1-82-5-8 0-5-122-5-4
0-5-12
17-11-8
17-5-12
17-5-121-8-00-4-00-4-01-4-01-8-0Scale = 1:34.6
Plate Offsets (X, Y):[8:0-3-0,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.45 Vert(LL)-0.17 11-12 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.88 Vert(CT)-0.27 11-12 >801 360
BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(CT)0.14 15 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 73 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)13=1056/0-5-8, (min. 0-1-8), 15=1059/0-5-4, (min. 0-1-8)
26 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2536/0, 3-4=-2536/0, 4-5=-3035/0, 5-6=-3035/0, 6-7=-1616/0, 7-8=-1616/0, 8-15=-1059/0
BOT CHORD 12-13=0/1541, 11-12=0/3010, 10-11=0/2538
WEBS 2-13=-1794/0, 2-12=0/1169, 3-12=-265/0, 4-12=-557/0, 5-11=-276/0, 6-11=0/583, 6-10=-1084/0, 7-10=-322/0,8-10=0/1870
NOTES
1)Bearing at joint(s) 15 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
2)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
3)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outerends or restrained by other means.
4)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A FF3 7 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:49 Page: 1
ID:E0tDm84mWpXGwjt8TZgs3YziFw_-jCI7PJI9724Sx4Pw1DBZVT1HAj4gjTg2iccbdZyLzXy
=3x4
=6x6
=5x8 =1.5x3
=4x6
=4x8 =1.5x3 =3x4
=1.5x3
=3x6
=3x4
=1.5x3
=5x12
=5x8
=3x4
15 14 13 12 11 101617
1 2 3 4 5 6 7 8 9
W3W2BL1BL1 BL1BL1W1W1
T1
B1
W40-5-121-1-142-5-8 0-5-121-1-142-5-4
0-11-14
1-5-10
0-5-12
0-5-12
0-5-12
17-11-8
3-8-10
5-2-4
12-3-8
17-5-121-8-00-4-00-4-01-4-01-8-00-4-00-4-01-4-01-8-0Scale = 1:37.8
Plate Offsets (X, Y):[9:0-3-0,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.45 Vert(LL)-0.17 12-13 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.89 Vert(CT)-0.27 12-13 >783 360
BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(CT)0.15 17 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 75 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)16=1059/0-5-4, (min. 0-1-8), 17=1059/0-5-4, (min. 0-1-8)
27 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-865/0, 2-3=-865/0, 3-4=-2536/0, 4-5=-2536/0, 5-6=-3036/0, 6-7=-3036/0, 7-8=-1616/0, 8-9=-1616/0, 1-16=-1059/0,9-17=-1059/0
BOT CHORD 13-14=0/1532, 12-13=0/3007, 11-12=0/2539
WEBS 4-13=-282/0, 1-14=0/1316, 3-13=0/1179, 3-14=-1076/0, 5-13=-554/0, 6-12=-278/0, 7-12=0/585, 7-11=-1084/0,8-11=-322/0, 9-11=0/1870
NOTES
1)Bearing at joint(s) 16, 17 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
2)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
3)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
4)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A FF4 1 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:49 Page: 1
ID:E0tDm84mWpXGwjt8TZgs3YziFw_-jCI7PJI9724Sx4Pw1DBZVT1HAj4bjTg2iccbdZyLzXy
3x6 FP
3x6 FP
=3x4
=3x6
=3x6
=3x8 =1.5x3 =3x4
=4x8 =1.5x3 =3x8
=4x4
=5x5 =3x4
=4x10
=4x6
=4x4
=3x6 =1.5x3
=3x8
=3x4 =1.5x3
=4x8
=4x6
=4x6 =3x4
26
25 24 23 22 21 20 19 18
17
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
W1 W3
T1
B2B1
T2
W5W4W2 W6
0-8-122-0-0 2-3-12
2-5-4 2-7-4
2-9-8
20-0-8
4-9-0
4-9-0
12-6-0
17-3-0
13-5-12
33-6-41-8-01-8-0Scale = 1:55.6
Plate Offsets (X, Y):[7:0-1-8,Edge], [10:0-1-8,Edge], [17:Edge,0-1-8], [20:0-1-8,Edge], [23:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 1.00 Vert(LL)-0.11 24-25 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.69 Vert(CT)-0.16 24-25 >999 240
BCLL 0.0 Rep Stress Incr NO WB 0.48 Horz(CT)0.04 17 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 139 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 1650F 1.5E(flat) *Except* T2:2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size)17=978/ Mechanical, (min. 0-1-8), 21=2463/0-5-8, (min.0-1-10), 26=802/ Mechanical, (min. 0-1-8)
Max Grav 17=1109 (LC 10), 21=2463 (LC 1), 26=871 (LC 5)
28 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 16-17=-498/0, 2-3=-1827/0, 3-4=-1827/0, 4-5=-1879/0, 5-6=-1879/0, 6-7=0/885, 7-8=0/2450, 8-9=0/2451, 9-10=0/2451,
10-11=-168/941, 11-12=-1746/33, 12-13=-1746/33, 13-14=-1380/0, 14-15=-1380/0
BOT CHORD 25-26=0/1051, 24-25=0/2076, 23-24=-349/1154, 22-23=-885/0, 21-22=-885/0, 20-21=-941/168, 19-20=-423/1173,
18-19=0/1784, 17-18=0/448
WEBS 3-25=-272/0, 8-21=-310/0, 10-20=0/746, 2-25=0/912, 2-26=-1298/0, 4-25=-293/94, 4-24=-365/0, 5-24=-275/0,
6-24=0/982, 6-23=-1512/0, 7-23=0/829, 7-21=-2081/0, 10-21=-2135/0, 11-20=-1352/0, 11-19=0/835, 12-19=-276/0,
13-18=-475/74, 14-18=-281/0, 15-18=0/1096, 15-17=-924/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
4)Load case(s) 1, 3 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
6)CAUTION, Do not erect truss backwards.
7)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 500 lb down at 33-4-12 on top chord. The design/selection of such
connection device(s) is the responsibility of others.
8)In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 17-26=-10, 1-16=-110
Concentrated Loads (lb)
Vert: 16=-250 (F)
3)Dead + Roof Live (balanced): Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90
Uniform Loads (lb/ft)
Vert: 17-26=-10, 1-16=-30
Concentrated Loads (lb)
Vert: 16=-500 (F)
Job Truss Truss Type Qty Ply Roof
325790-A FF5 4 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:50 Page: 1
ID:zBjnFI6BAOeGdh1g2XVqSRziF50-BOsVcfJnuMCJZE_6bwio2gZKO7TtSwjBxGL89?yLzXx
3x6 FP
3x6 FP
=3x4
=3x6
=3x6
=3x8 =1.5x3 =3x4
=4x8 =1.5x3 =3x8
=4x4
=5x5 =3x4
=4x10
=4x6
=4x4
=3x6 =1.5x3
=3x8
=3x4 =1.5x3
=4x8
=4x6
=4x6 =3x4
26
25 24 23 22 21 20 19 18
17
1 2 3 4 5 6 7 8 9 10 11 12 13 14 2715 16
W1 W3
T1
B2B1
T2
W5W4W2 W6
0-8-122-0-0 2-3-12
2-5-4 2-7-4
2-9-8
20-0-8
4-9-0
4-9-0
12-6-0
17-3-0
13-5-12
33-6-41-8-01-8-0Scale = 1:55.6
Plate Offsets (X, Y):[7:0-1-8,Edge], [10:0-1-8,Edge], [17:Edge,0-1-8], [20:0-1-8,Edge], [23:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 1.00 Vert(LL)-0.11 24-25 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.69 Vert(CT)-0.16 24-25 >999 240
BCLL 0.0 Rep Stress Incr NO WB 0.48 Horz(CT)0.04 17 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 139 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 1650F 1.5E(flat) *Except* T2:2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size)17=1109/ Mechanical, (min. 0-1-8), 21=2471/0-5-8, (min.0-1-11), 26=800/ Mechanical, (min. 0-1-8)
Max Grav 17=1240 (LC 10), 21=2471 (LC 1), 26=870 (LC 5)
29 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 16-17=-529/0, 2-3=-1824/0, 3-4=-1824/0, 4-5=-1872/0, 5-6=-1872/0, 6-7=0/896, 7-8=0/2463, 8-9=0/2464, 9-10=0/2464,
10-11=-167/941, 11-12=-1768/10, 12-13=-1768/10, 13-14=-1426/0, 14-27=-1426/0, 15-27=-1426/0
BOT CHORD 25-26=0/1049, 24-25=0/2071, 23-24=-358/1144, 22-23=-896/0, 21-22=-896/0, 20-21=-941/167, 19-20=-412/1184,
18-19=0/1818, 17-18=0/502
WEBS 3-25=-272/0, 8-21=-310/0, 10-20=0/753, 2-25=0/910, 2-26=-1296/0, 4-25=-291/97, 4-24=-367/0, 5-24=-275/0,
6-24=0/984, 6-23=-1514/0, 7-23=0/831, 7-21=-2083/0, 10-21=-2150/0, 11-20=-1365/0, 11-19=0/849, 12-19=-277/0,
13-18=-461/89, 14-18=-283/0, 15-18=0/1086, 15-17=-1037/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
4)Load case(s) 1, 3 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
6)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 17-26=-10, 1-27=-110, 16-27=-210
Concentrated Loads (lb)
Vert: 16=-250
3)Dead + Roof Live (balanced): Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90
Uniform Loads (lb/ft)
Vert: 17-26=-10, 1-27=-30, 16-27=-130
Concentrated Loads (lb)
Vert: 16=-500
Job Truss Truss Type Qty Ply Roof
325790-A FF6 1 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:50 Page: 1
ID:p6BdEqrIHb3NZtRtw7YwM0zU7xl-BOsVcfJnuMCJZE_6bwio2gZKK7TvSwgBxGL89?yLzXx
3x6 FP
3x6 FP
=3x4
=3x6
=3x6
=3x8 =1.5x3 =3x4
=4x8 =1.5x3 =3x8
=4x4
=5x5 =3x4
=4x10
=4x6
=4x4
=3x6 =1.5x3
=3x8
=3x4 =1.5x3
=4x8
=4x6
=4x6 =3x4
26
25 24 23 22 21 20 19 18
17
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
W1 W3
T1
B2B1
T2
W5W4W2 W6
0-8-122-0-0 2-3-12
2-5-4 2-7-4
2-9-8
20-0-8
4-9-0
4-9-0
12-6-0
17-3-0
13-5-12
33-6-41-8-01-8-0Scale = 1:55.6
Plate Offsets (X, Y):[7:0-1-8,Edge], [10:0-1-8,Edge], [17:Edge,0-1-8], [20:0-1-8,Edge], [23:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.78 Vert(LL)-0.11 24-25 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.69 Vert(CT)-0.16 24-25 >999 240
BCLL 0.0 Rep Stress Incr NO WB 0.48 Horz(CT)0.04 17 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 139 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF 1650F 1.5E(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size)17=962/ Mechanical, (min. 0-1-8), 21=2482/0-5-8, (min.0-1-11), 26=798/ Mechanical, (min. 0-1-8)
Max Grav 17=1082 (LC 10), 21=2482 (LC 1), 26=867 (LC 5)
30 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1815/0, 3-4=-1815/0, 4-5=-1854/0, 5-6=-1854/0, 6-7=0/902, 7-8=0/2485, 8-9=0/2486, 9-10=0/2486, 10-11=-175/954,
11-12=-1802/0, 12-13=-1802/0, 13-14=-1486/0, 14-15=-1486/0
BOT CHORD 25-26=0/1045, 24-25=0/2058, 23-24=-363/1122, 22-23=-902/0, 21-22=-902/0, 20-21=-954/175, 19-20=-408/1205,
18-19=0/1865, 17-18=0/593
WEBS 3-25=-272/0, 8-21=-309/0, 10-20=0/762, 2-25=0/904, 2-26=-1291/0, 4-25=-285/98, 4-24=-371/0, 5-24=-275/0,
6-24=0/988, 6-23=-1518/0, 7-23=0/832, 7-21=-2088/0, 10-21=-2170/0, 11-20=-1383/0, 11-19=0/867, 12-19=-277/0,
13-19=-251/0, 13-18=-446/108, 14-18=-282/0, 15-18=0/1068, 15-17=-1225/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
4)Load case(s) 1, 3 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
6)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 17-26=-10, 1-16=-110
Concentrated Loads (lb)
Vert: 15=-250
3)Dead + Roof Live (balanced): Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90
Uniform Loads (lb/ft)
Vert: 17-26=-10, 1-16=-30
Concentrated Loads (lb)
Vert: 15=-500
Job Truss Truss Type Qty Ply Roof
325790-A FF7 1 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:51 Page: 1
ID:WarFTtNuw7c8qeoLVNLE8IzU7x3-faQuq?JPfgK9ANZI9eD1bu6YWXpCBNrL9w5hhSyLzXw
=3x4
=3x6
=4x6
=4x8 =1.5x3
=3x4 =1.5x3
=3x6
=3x4
=4x4
=4x4
=3x6 =1.5x3
=1.5x3
13
12 11 10
9
1412345678
W1 W3
B1
T1
W4W2 BL1
2-0-0 2-5-0 0-1-82-5-4
4-9-0
4-9-0
12-8-12
17-5-121-8-01-8-0Scale = 1:31.7
Plate Offsets (X, Y):[7:0-1-8,Edge], [10:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.40 Vert(LL)-0.15 11-12 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.82 Vert(CT)-0.24 11-12 >877 360
BCLL 0.0 Rep Stress Incr YES WB 0.37 Horz(CT)0.06 9 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 73 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)9=1027/0-5-8, (min. 0-1-8), 13=1034/ Mechanical, (min. 0-1-8)
31 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2314/0, 3-4=-2314/0, 4-5=-2892/0, 5-6=-2892/0, 6-7=-1536/0
BOT CHORD 12-13=0/1275, 11-12=0/2826, 10-11=0/2428, 9-10=0/1536
WEBS 3-12=-272/0, 2-12=0/1221, 2-13=-1575/0, 4-12=-602/0, 5-11=-277/0, 6-11=0/545, 6-10=-1049/0, 7-10=0/593, 7-9=-1780/0
NOTES
1)Refer to girder(s) for truss to truss connections.
2)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
3)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outerends or restrained by other means.
4)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A FF8 5 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:51 Page: 1
ID:uQJbqRqpX06uX_maiSygydzU8Ql-faQuq?JPfgK9ANZI9eD1bu6eYXn4BPaL9w5hhSyLzXw
=3x4 =3x4
=3x4
28
27 26 25 24 23 22 21 20 19 18 17 16 15
291234567891011121314
ST1W1W1 W1
B1
T1
BL10-1-817-5-12
17-5-121-8-01-8-0Scale = 1:31.7
Plate Offsets (X, Y):[28:Edge,0-1-8]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.07 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.01 Vert(TL)n/a -n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.02 Horiz(TL)0.00 15 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-R Weight: 65 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 17-5-12.
(lb) -Max Grav All reactions 250 (lb) or less at joint(s) 15, 16, 17, 18, 19, 20,
21, 22, 23, 24, 25, 26, 27, 28
32 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1)All plates are 1.5x3 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4)Gable studs spaced at 1-4-0 oc.
5)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outerends or restrained by other means.
7)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A FF9 1 1Floor Supported Gable Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:52 Page: 1
ID:LW3Ti3dr0s7rRbiMNR5jp9ziEI_-faQuq?JPfgK9ANZI9eD1bu6jaXzhBU2L9w5hhSyLzXw
=3x4
=3x6
=3x4
=3x6 =3x4
=3x4
=3x6 =3x4
8
7
6
1 2 3 4 5
W1 W3W2W2
T1
B1
1-7-12 1-10-8
1-7-12
3-8-0
3-8-0
4-1-8
7-9-81-8-01-8-0Scale = 1:20.8
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.45 Vert(LL)-0.11 6-7 >436 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.80 Vert(CT)-0.18 6-7 >262 240
BCLL 0.0 Rep Stress Incr NO WB 0.08 Horz(CT)0.00 6 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-P Weight: 38 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF 1650F 1.5E(flat)
WEBS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 7-9-8 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)6=504/0-5-8, (min. 0-1-8), 7=1335/0-3-8, (min. 0-1-8), 8=424/
Mechanical, (min. 0-1-8)
Max Grav 6=512 (LC 4), 7=1335 (LC 1), 8=437 (LC 3)
33 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BOT CHORD 6-7=0/260
WEBS 3-7=-357/0, 2-7=-365/0, 2-8=-261/0, 4-6=-328/0, 4-7=-436/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
4)Load case(s) 1 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outerends or restrained by other means.
6)CAUTION, Do not erect truss backwards.
7)In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 6-8=-100 (F=-90), 1-5=-200 (F=-90)
Job Truss Truss Type Qty Ply Roof
325790-A FF10 1 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:52 Page: 1
ID:v5xsDG0RyfiCAD0velFs_aziFXX-7m_G1LK1QzS0oX7ViLkG75fpWx7fwwPUOaqFEuyLzXv
=3x4 =3x4
22 21 20 19 18 17 16 15 14 13 12
23 24
1 2 3 4 5 6 7 8 9 10 11
ST1W1 W1BL1BL1
B1
T10-1-80-1-812-7-8
12-7-81-8-01-8-0Scale = 1:24.4
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.07 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.02 Vert(TL)n/a -n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.02 Horiz(TL)0.00 12 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-R Weight: 49 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 12-7-8.
(lb) -Max Grav All reactions 250 (lb) or less at joint(s) 12, 13, 14, 15, 16, 17,
18, 19, 20, 21, 22
34 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1)All plates are 1.5x3 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4)Gable studs spaced at 1-4-0 oc.5)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A FF11 1 1Floor Supported Gable Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:52 Page: 1
ID:5bQhJE5X4ylodacILHLhyXzU7qz-7m_G1LK1QzS0oX7ViLkG75fuJxJswxHUOaqFEuyLzXv
=1.5x3 =1.5x3
=3x6
=3x4
=3x6 =1.5x3
=3x4
=3x4
=3x4
=3x6 =1.5x3
=1.5x3
10
9 8
7
11 12
1 2 3 4 5 6
W2W1BL1 BL1
B1
T1
W30-1-82-1-8 0-1-82-5-4
12-7-8
12-7-81-8-01-8-0Scale = 1:24.4
Plate Offsets (X, Y):[5:0-1-8,Edge], [8:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.33 Vert(LL)-0.05 8-9 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.49 Vert(CT)-0.09 9-10 >999 240
BCLL 0.0 Rep Stress Incr YES WB 0.25 Horz(CT)0.02 7 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 54 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)7=736/0-5-8, (min. 0-1-8), 10=736/0-5-8, (min. 0-1-8)
35 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1489/0, 3-4=-1489/0, 4-5=-952/0
BOT CHORD 9-10=0/1011, 8-9=0/1442, 7-8=0/952
WEBS 2-10=-1175/0, 2-9=0/561, 3-9=-266/0, 4-8=-576/0, 5-8=0/341, 5-7=-1140/0
NOTES
1)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
2)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A FF12 5 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:53 Page: 1
ID:YYzpMNKoaX0wLh4HsRdoH9ziFQg-7m_G1LK1QzS0oX7ViLkG75fqFxCYwumUOaqFEuyLzXv
=3x4
=4x6
=4x4
=4x4
=3x6
=3x8 =1.5x3
=3x4
=1.5x3
=3x8
=3x6
=4x4
=4x4
=4x6 =1.5x3
=1.5x3
15
14 13 12 11
10
16123456789
W1 W3
B1
T1
W2 W4 BL1
2-2-8
2-1-8 0-1-82-5-4
2-6-4
2-6-4
17-5-4
19-11-81-8-01-8-0Scale = 1:35.4
Plate Offsets (X, Y):[2:0-1-8,Edge], [8:0-1-8,Edge], [10:Edge,0-1-8], [11:0-1-8,Edge], [14:0-1-8,Edge]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.52 Vert(LL)-0.24 12-13 >983 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.73 Vert(CT)-0.38 12-13 >628 240
BCLL 0.0 Rep Stress Incr YES WB 0.39 Horz(CT)0.08 10 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 83 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF 1650F 1.5E(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)10=1176/0-5-8, (min. 0-1-8), 15=1182/ Mechanical, (min. 0-1-8)
36 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1664/0, 3-4=-3586/0, 4-5=-3586/0, 5-6=-3570/0, 6-7=-3570/0, 7-8=-1613/0
BOT CHORD 14-15=0/1664, 13-14=0/2843, 12-13=0/3801, 11-12=0/2811, 10-11=0/1613
WEBS 2-14=0/768, 2-15=-1979/0, 3-14=-1384/0, 3-13=0/874, 4-13=-275/0, 5-13=-253/0, 5-12=-272/0, 6-12=-274/0, 7-12=0/891,7-11=-1408/0, 8-11=0/780, 8-10=-1933/0
NOTES
1)Refer to girder(s) for truss to truss connections.
2)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
3)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outerends or restrained by other means.
4)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A FF13 4 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:53 Page: 1
ID:6SR8LndIKjoiTGyEkOcGCvziFUA-czYeEhLfBHatQhihG3GVgJBy3LTzfIoedEaomKyLzXu
=3x4
=3x6
=4x4
=3x4
=3x4
=3x6 =1.5x3
=3x4
=1.5x3
=4x10
=4x8
=4x6 =3x4
13
12 11 10
9
1 2 3 4 5 6 7 8
W1 W3
T1
B1
W2 W4
0-8-12
2-2-8
2-5-4
2-6-4
2-6-4
13-5-12
16-0-01-8-01-8-0Scale = 1:29.5
Plate Offsets (X, Y):[2:0-1-8,Edge], [9:Edge,0-1-8]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.39 Vert(LL)-0.11 10-11 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.75 Vert(CT)-0.17 10-11 >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.38 Horz(CT)0.04 9 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 69 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)9=1195/ Mechanical, (min. 0-1-8), 13=945/ Mechanical, (min.0-1-8)
Max Grav 9=1225 (LC 4), 13=945 (LC 1)
37 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 8-9=-498/0, 2-3=-1296/0, 3-4=-2450/0, 4-5=-2450/0, 5-6=-1663/0, 6-7=-1663/0
BOT CHORD 12-13=0/1296, 11-12=0/2090, 10-11=0/2279, 9-10=0/520
WEBS 2-12=0/531, 2-13=-1541/0, 3-12=-933/0, 3-11=0/423, 4-11=-276/0, 5-10=-723/0, 6-10=-281/0, 7-10=0/1343, 7-9=-1073/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
4)Load case(s) 1, 3 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outerends or restrained by other means.
6)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 9-13=-10, 1-8=-110
Concentrated Loads (lb)
Vert: 8=-250
3)Dead + Roof Live (balanced): Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90
Uniform Loads (lb/ft)
Vert: 9-13=-10, 1-8=-30
Concentrated Loads (lb)
Vert: 8=-500
Job Truss Truss Type Qty Ply Roof
325790-A FF14 3 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:53 Page: 1
ID:gsq0nG6xVC4q0WzbctnpteziFPg-czYeEhLfBHatQhihG3GVgJB_CLTdfJzedEaomKyLzXu
=3x4
=3x6
=4x6
=4x8 =1.5x3
=3x4
=3x6 =1.5x3
=3x4 =1.5x3
=4x10
=4x8
=4x6 =3x4
14
13 12 11
10
1 2 3 4 5 6 7 8 9
W1 W3W2W2
T1
B1
W4
1-4-4 2-5-4
0-8-12
1-4-4
3-0-4
3-0-4
13-5-12
16-6-01-8-01-8-0Scale = 1:30.2
Plate Offsets (X, Y):[10:Edge,0-1-8]
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.42 Vert(LL)-0.12 11-12 >999 480 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.79 Vert(CT)-0.19 11-12 >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.40 Horz(CT)0.05 10 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-S Weight: 71 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)10=1225/ Mechanical, (min. 0-1-8), 14=975/0-5-8, (min. 0-1-8)
Max Grav 10=1250 (LC 4), 14=975 (LC 1)
38 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 9-10=-497/0, 2-3=-1539/0, 3-4=-1539/0, 4-5=-2611/0, 5-6=-2611/0, 6-7=-1728/0, 7-8=-1728/0
BOT CHORD 13-14=0/859, 12-13=0/2306, 11-12=0/2392, 10-11=0/537
WEBS 2-13=0/1006, 2-14=-1241/0, 4-13=-901/0, 4-12=0/359, 5-12=-272/0, 6-12=0/257, 6-11=-780/0, 7-11=-280/0, 8-11=0/1400,
8-10=-1107/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s) for truss to truss connections.
3)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
4)Load case(s) 1, 3 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss.
5)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outerends or restrained by other means.
6)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
1)Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00
Uniform Loads (lb/ft)
Vert: 10-14=-10, 1-9=-110
Concentrated Loads (lb)
Vert: 9=-250
3)Dead + Roof Live (balanced): Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90
Uniform Loads (lb/ft)
Vert: 10-14=-10, 1-9=-30
Concentrated Loads (lb)
Vert: 9=-500
Job Truss Truss Type Qty Ply Roof
325790-A FF15 3 1Floor Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:54 Page: 1
ID:p3OBCrKkPQ8tTeSlqpZjnEziFMp-4950S1MHybik1rHtqmnkCWk9RkoLOlznruJLInyLzXt
=3x4
=1.5x3 =1.5x3
=1.5x3 =1.5x3
=1.5x3 =1.5x3
=1.5x3 =1.5x3
8
7 6
5
9
1 2 3 4
W1 ST1 ST1
B1
T1
BL1 0-1-83-4-10
3-4-101-8-01-8-0Scale = 1:21.5
Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP
TCLL 40.0 Plate Grip DOL 1.00 TC 0.07 Vert(LL)n/a -n/a 999 MT20 197/144
TCDL 15.0 Lumber DOL 1.00 BC 0.01 Vert(TL)n/a -n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.02 Horiz(TL)0.00 5 n/a n/a
BCDL 5.0 Code IRC2018/TPI2014 Matrix-R Weight: 15 lb FT = 20%F, 11%E
LUMBER
TOP CHORD 2x4 SPF No.2(flat)
BOT CHORD 2x4 SPF No.2(flat)
WEBS 2x4 SPF No.2(flat)
OTHERS 2x4 SPF No.2(flat)
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-4-10 oc purlins,except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 3-4-10.
(lb) -Max Grav All reactions 250 (lb) or less at joint(s) 5, 6, 7, 8
39 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES
1)All plates are 1.5x3 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
4)Gable studs spaced at 1-4-0 oc.
5)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
6)Recommend 2x6 strongbacks, on edge, spaced at 10-00-00 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer
ends or restrained by other means.
7)CAUTION, Do not erect truss backwards.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Ply Roof
325790-A FF16 1 1Floor Supported Gable Job Reference (optional)
Villaume Industries, St Paul, MN Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Mon Nov 06 07:32:54 Page: 1
ID:8TvNYsoT0zIOKc?6HYqSM3zU7mB-4950S1MHybik1rHtqmnkCWkErk_POrnnruJLInyLzXt
SEMI-FLUSH HEADER BY OTHERSTHA422FLUSH HEADERBY OTHERS18" DEEP TRUSSES24" O.C. BASE SPACING.DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING. TRUSSES HAVE BEEN HELD IN1/2" AT EXTERIOR WALLS FOR SHEATHING.THE PAINTED END DENOTES THE LEFT ENDOF THE FLOOR TRUSS. THIS END OF THEFLOOR TRUSS IS TO BE PLACED WHERE YOUSEE THE TRIANGLE AND THE PAINTED ENDNOTE ON THE PLACEMENT PLAN. THEPAINTED END ALSO CORRESPONDS TO THELEFT SIDE OF THE SEALED TRUSS DRAWING.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBINGLOCATIONSEXTRA TRUSS ADDED FOR PLUMBING.SHIFT TRUSSES TO AVOID PLUMBING.DO NOT OVER SPACE TRUSSES."F14" TRUSS SUPPORTED BY SINGLE 2X10HEADER. ATTACH HEADER TO ADJACENTTRUSS VERTICALS..DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLANDY @ 651-688-3613OREMAIL: AHOERNEMANN@VILLAUME.COMF1F2F3F4F4F4F6F6F6F6F20F20F20F20F20F23F19F7F16F16F16F16F16F16F16F10F10F10F10F9F9F9F9F9F9F9F8F22F11F11F12F11F13F14F17F21F21F21F21F15F18F515-00-0016-00-0018-00-0018-00-007-04-0012-00-0038-00-0019-00-0030-00-003-00-003-00-003-06-0021-06-007-00-0023-00-008-00-008-00-008-00-008-00-008-00-009-00-0012-08-002-00-002-00-0018-00-0012-03-04Customer: Lyman Lumber - ChanhassenJob Number: 325790-AHome Owner: TOPAZ / BROOKE / YOCKEY RESJob Name: RoofSite Address: 17700 ELLSWORTH DR Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Andy Hoernemann2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 11/6/2023Version: 8.5.3.233
MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -6 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"GARAGE PLATE HEIGHT10' - 9 3/8"SMARTSIDE FRIEZEBOARD @ FRONT TYP.VINYL BOARD & BATTEN CULTURED STONEW/ CONCRETE CAPALUMINUM SOFFIT& FASCIA TYP.6" BUMP-OUT GABLE END W/ VINYL BOARD & BATTEN ADDRESS STONE 6"x6"x30" CORBELS TYP.8" SMARTSIDEFRIEZE BD.3' - 6"3' - 6"6" BUMP-OUT GABLE END W/ VINYL BOARD & BATTENW/ PAINTED CORBELS SEE COLUMN DETAIL SHEET A-5018" / 12"8" / 12"8" / 12"5" / 12"5" / 12"10" 12"10" 12"10" 12"12036 NVH1R.O. 2' -0" x 3' -6"H.H. 12' -9 3/4"3' - 6"VINYL SIDING &CORNERS TYP.6" SMARTSIDE WINDOW & DOOR TRIM TYP. @ FRONT 24" RETURN TYP.8" 12"7" / 12"10" / 12"10" / 12"8" / 12"5" 12"MAIN FLOOR1' -8 1/4"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING &CORNERS @SIDES & REAR OWNER'S SUITE PLATE21' -7 1/4"OWNER'S SUITE FLOOR13' -6 1/8"GREAT RM. PLATE11' -9 3/8"10' - 1 1/8"8' - 1 1/8"8" / 12"5" / 12"7" 12"24" RETURN TYP.8" 12"5" 12"10" / 12"10" / 12"10" / 12"7" / 12"0' - 5 1/2"0' - 5 1/2"6x60' - 5 1/2"FRONT VIEWSIDE VIEW 0' - 2"0' - 3 1/2"0' - 3 1/2"0' - 5 1/2"R 0' - 2"0' - 5 1/2"2' - 6"6x60' - 5 1/4"0' - 5 1/4"FRONT VIEWSIDE VIEW 0' - 2 1/8"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:10/18/2023 2:59:56 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-201OTT40710.18.23 CB16111539119110.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKE1/4" = 1'-0"A-2011FRONT ELEVATION1/8" = 1'-0"A-2012RIGHT ELEVATION1/8" = 1'-0"A-2013REAR ELEVATION1/8" = 1'-0"A-2014LEFT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONSA-401 FOUNDATIONA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 ROOF/ SCHEDULES/ DETALSA-502 DETAILS3/4" = 1'-0"A-2015CORBEL DETAIL - 6x61/2" = 1'-0"A-2016CORBEL DETAIL - 6x6x30
19' - 10"1' - 10"2' - 0"1' - 10 1/2"16' - 3" M.O.1' - 10 1/2"0' - 7 1/2"8' - 3" M.O.1' - 7 1/2"8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"0' - 4"* ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATION12' - 7 1/4"3' - 10 3/4"3' - 10 3/4"17' - 9 1/4"8' - 11 3/4"17' - 10 1/4"2' - 10"8' - 0 1/2"7' - 4 1/2"3' - 11"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.12' - 0"38' - 2"5' - 10"2' - 0"7' - 10"50' - 2"19' - 4"1' - 0"20' - 0"10' - 6"30' - 6"19' - 6"4' - 0"23' - 8"23' - 4"7' - 0"27' - 8"30' - 4"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.* ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATION6' - 0"2' - 2"36' - 0"9' - 0"11' - 6"3' - 10 3/4"15' - 11 1/4"29' - 8"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY50' - 0"1' - 0"7' - 8 3/4"15' - 11 1/4"42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY48" x 48" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAYLEAVE A 12" GAP IN THE FOOTING FOR PLUMBING 1' - 0"49' - 0"18' - 0"16' - 0"15' - 0"58' - 0"58' - 0"15' - 8 3/4"15' - 3 1/4"42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY5' - 3 1/4"18' - 0 3/4"50' - 0"54 x 54" x 12" CONCRETE FTG.W/ (6) #5 REBAR EACH WAY:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY11' - 11 1/4"7' - 4 3/4":LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODESTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:10/18/2023 2:59:57 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-401OTT40710.18.23 CB16111539119110.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKE1/4" = 1'-0"A-4011FOUNDATION PLAN
UNEXCAVATEDUNEXCAVATED4-14" LVL DROPPED 8"0' - 4"2" FOAM INSULATIONBETWEEN WALL & SLAB62/8 x 6/8R.O. 2' -10" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"(5) 16" SH.62/8 x 6/8R.O. 2' -10" x 6' -11"9' - 0"5' - 10"MECHANICALBATHFAMILY ROOMGAME ROOMFURNACEW. H.F. D.SUMPAIR EX.3' - 8"15' - 8"0' - 4"2' - 0"5' - 10"38' - 2"12' - 0"7' - 10"50' - 2"19' - 4"1' - 0"CANT. JOIST2' - 0"1' - 10"19' - 10"9' - 0"11' - 6"30' - 6"19' - 6"15' - 0"16' - 0"18' - 0"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2 TRIMMERS EA. SIDE 2-2x102-2x10*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/ SHEATHING*ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/ SHEATHING12' - 10"3' - 8"3' - 8"18' - 0"2-2x10CO DET.SMOKEDET.SMOKEDET.7x7 PSL W/ COLUMN CAPECCQ7.1-7.1SDS2.5 W/ STRAPS ROTATED 90°NO PLATES 36' - 0"2' - 2"6' - 0"1' - 10"27' - 8"30' - 4"20' - 0"10' - 6"1' - 0"29' - 8"18" CANT. ABOVE 50' - 0"7' - 0"23' - 4"23' - 8"4' - 0"12' - 6 1/4"18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING85040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"2' LINEN6' VANITY42/6 x 6/8R.O. 2' -8" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"6' - 6 1/4"4' - 2 3/4"0' - 8"11' - 11"12/4 x 6/8R.O. 2' -6" x 6' -11"R & SH.3' - 6 1/4"11' - 8"BEDROOM #548" F.G. SHWRHALF WALL6' - 2"4' - 2"1' - 0"49' - 0"50' - 0"CLOSET2x6.58' - 0"58' - 0"2-2x102-2x10 FLUSHGIRDER TRUSS3-2x62x8EQEQGAS LINE FOR FUTURE FIREPLACE GAS LINE FOR FUTURE GRILL9' - 0"9' - 0"8' - 0"8' - 0"7' - 6"7' - 6"108040E NVGER.O. 8' -0" x 4' -0"H.H. 6' -10"116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"6' - 3"5' - 9"85040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"5x5 PSLSTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.3' - 3"B.W.P.4' - 0"B.W.P.4' - 0"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:10/18/2023 2:59:59 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-402OTT40710.18.23 CB16111539119110.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKE1/4" = 1'-0"A-4021LOWER FLOOR PLAN||[]][]|[||]][[]|[||]][][|||3-2x10= Loaded for Future Deck Load2-2x102-2x107x7 PSLOK5x7 PSLOK4-2x6w SquashBlocking3 - 9-1/2" LVL 3 - TrimmersOK2 - 9-1/2" LSLOK*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***
12' - 0"38' - 0"6' - 0"2' - 0"1' - 0"49' - 0"SINGLE BOWLUNDERMOUNTSINK S.S.DWPORCH19' - 6"30' - 6"1' - 9"8' - 0"0' - 9"2' - 0"16' - 0"2' - 0"1' - 0"4" REINFORCED CONCRETE SLAB,SLOPE TOWARDS DOORS5/8" TYPE X GYP. BD. CEILING1/2" GYP. GB. ON GARAGE WALLS GARAGE PLATE HEIGHT TOMATCH MAIN FLOOR PLATER-38 MIN INSULATION IN FLOOR ABOVE 128' x 8' O.H. GARAGE DOOR8' - 0"50' - 0"18' - 0"16' - 0"15' - 0"GARAGEDBLOVENGAS F.P.30' - 0"EQEQFULL HEIGHT IRONSPINDLE RAILING 18' - 0"3' - 8"3' - 8"12' - 8"SEE COLUMN DETAIL SHEET A-50150' - 0"2' - 0"17' - 0"3' - 0"LOCKERS.83/0 x 6/8 ARCH4' - 3 1/2"5' - 0"3' - 4"9' - 0"3' - 6"CLOSETPOWDERMUD RM.12/4 x 6/8R.O. 2' -6" x 6' -11"42" PANTRY36" REF36" GASCOOKTOPW/ HOOD42" HALF WALLW/ WOOD CAPDINING2' - 0"STONE TO CEILING93/0 x 6/8 W/ 2-12" D.S. S.L.'SSTEEL7' - 10"0' - 10"5' - 10"GREAT ROOM5' - 4 1/4"5' - 1 3/4"5' - 6"7' - 0"5' - 0"6' - 2"PED. SINKGIRDER TRUSSWHITE PAINTED CABINETS & TILE BACKSPLASHKITCHEN3-16" LVL FLUSH CONTINUOUS5' - 9"3' - 9"5' - 9 1/4"7' - 10"11' - 2"OFFICEFOYER4' - 0"9' - 3"5' - 9"19' - 0"2' - 0"3' - 6"2' - 0"19' - 6"3' - 0"58' - 0"12' - 10"2' - 2"8' - 0"8' - 0"8' - 6"9' - 6"0' - 8" TYP.38' - 0"5' - 4"0' - 8"B.W.P.4' - 0"B.W.P.8' - 0"B.W.P.6' - 5"B.W.P.2' - 8"B.W.P.2' - 7"5' - 9"6' - 3"B.W.P.3' - 7"B.W.P.8' - 0"B.W.P.4' - 0"4' - 0" B.W.P.B.W.P.2' - 3"B.W.P.2' - 8"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"3-2x63-2x63-18" LVL FLUSH3-2x102-2x123-9 1/2" LSL2-2x103-9 1/2" LSL2-TRIMMERS5'-0" COUNTER HGT.BUFFET W/ TILE BACKSPLASH1' - 1"3-16" LVL FLUSHTRASH PULLOUT B.W.P.8' - 0"SMOKEDET.20' - 0"10' - 6"8' - 0"11' - 6"0' - 8"7' - 8"0' - 8"10' - 10"0' - 8"WALL ABOVE BEARING ON FLOOR TRUSSESB.W.P.4' - 0"4-TRIMMERSFRIDGE RECESS 39"x73"x2"MONO GIRDER2-2x102-9 1/2" LVL DROPPED2-9 1/2" LSLDROPPED 2-TRIMMERSEA. SIDE2-2x10 SET 6" OFF FIREPLACE @ FINISHED FLOOR 12"x12" GYP.BD. SOFFIT12/4 x 6/8R.O. 2' -6" x 6' -11"MICROCABINET 9"x5' ISLANDW/ 6" LEGSFLUSH SNACK BAR1316' x 8' O.H. GARAGE DOOR2-TRIMMERSEA. SIDE2-2x102-2x102' - 0"0' - 8"1' - 4"0' - 6" TYP.28' - 0"30' - 0"3' - 4"3' - 8"58' - 0"50' - 0"STEP IN FLOOR ABOVE10'-1 1/8" CEILING9'-1 1/8" CEILING4' - 0"24' - 0"23' - 0"7' - 0"LUS4102-11 7/8" LSL2-2x105x7 PSL NO SPF PLATES SYP PLATES OK 2-2x12 CONTINUOUS 5x5 PSL W/ COLUMN CAPCCQ66SD2.5 NO PLATES5x5 PSLNO SPF PLATES SYP PLATES OK1' - 6"2-2x10DROPPED@ 6'-8" H.H. VAULT LINE 3.5:123.5:1218" DEEP PULLOUTS U.C. LIGHTU.C. LIGHTU.C. LIGHT4' - 3"12' - 3"STAINED WOODTOP ON 36" FRAMED WALLW/ (1) SHELF 5' - 3"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES32 FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.2' - 0"6' - 0"53350E NVH1R.O. 3' -3" x 5' -0"H.H. 6' -10"773650 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 6' -11 1/2"H.H. 8' -0"773650 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 6' -11 1/2"H.H. 8' -0"53350E NVH1R.O. 3' -3" x 5' -0"H.H. 6' -10"5' - 9 1/4"9' - 6"63636 NVG1R.O. 3' -6" x 3' -6"H.H. 6' -10"22/4 x 6/8 ARCH16" SH.16" SH.PANTRYPFH2' - 0"PFH2' - 0"PFH1' - 9"72/8 x 6/8R.O. 2' -10" x 6' -10 1/4"B.W.P.3' - 6"73650 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 6' -11 1/2"H.H. 8' -0"116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"B.W.P.2' - 8"2' - 0"5' - 4"0' - 8"6' - 0"2-2x102-2x10 DROPPED HANDERED INTO SIDE OF PSL W/ HUC28-24-2x64' - 0"77CS-PF2' - 1"CS-PF2' - 1"12/4 x 6/8R.O. 2' -6" x 6' -11"B.W.P.2' - 8"B.W.P.4' - 0"2' - 0"8' - 7"3' - 7"105/0 x 6/8 FULL VIEWR.O. 5' -2" x 6' -11"9" HEAT DUCTHGUS5.50/144-2x65x7 PSL NO SPF PLATES SYP PLATES OK R & SH @ 68"9' - 0"DBL. FRAMED WALLFOR REFG. RECESSU.C. LIGHTBUILT-IN CAB.BUILT-IN CAB.31" (W)x 18" (T)RECESS FOR TV MOUNT ABOVEADD BLOCKING 2-TRIMMERSFUTURE U.C. REF SHALLOWBASE1' - 7"ELONGATED 1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:10/18/2023 3:00:01 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-403OTT40710.18.23 CB16111539119110.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKE||[][]||[]][]|[][||]||[||||||OKOK3 - 14" LVL FLUSHOKOKOK4-2x62 - 9-1/2" LSL Cont.OKOKOKOKOKOK3-2x6OKOKOK3-2x103-2x10LUS210-32 - 9-1/2" LSLOKOK5x5 PSL Direct fromsupported memberto HeaderOKOKOKOK2 - TrimmersOK||[]OKOK][]|][[||]][[]|[||]][][|||*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***2-2x10
CO DET.SMOKEDET.SMOKEDET.SMOKEDET.SMOKEDET.EN SUITEPRIMARY SUITEVAULTEDBEDROOM #3HALLBEDROOM #412' - 8"3' - 8"3' - 8"18' - 0"4' - 0"1' - 0"15' - 0"18' - 0"16' - 4"21' - 8"30' - 8"5' - 10"4' - 6"52/6 x 6/8 PKTR.O. 5' -2" x 6' -11"BEDROOM #262/8 x 6/8R.O. 2' -10" x 6' -11"ATTICACCESS12/4 x 6/8R.O. 2' -6" x 6' -11"R & SH @ 68"9'-0" VANITY10' - 3"3' - 9"6' - 4"4' - 2"3' - 11"5' - 7"15' - 0"5' - 0"9' - 2"3' - 10"7' - 3"15' - 2 7/8"19' - 0 1/8"7' - 6"49' - 0"10' - 0"9' - 0"4' - 0"9' - 3"5' - 9"2-9 1/2" LSLB.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 0"B.W.P.4' - 9"B.W.P.4' - 0"B.W.P.2' - 8"B.W.P.4' - 0"B.W.P.4' - 0"42/6 x 6/8R.O. 2' -8" x 6' -11"3'-6" VANITY42/6 x 6/8R.O. 2' -8" x 6' -11"62/8 x 6/8R.O. 2' -10" x 6' -11"6' - 4"3' - 6"2' - 9"3' - 0"2' - 5"SEATCONTROLS (2) SHELVES STACKEDTILE SHOWER R & SH @ 42" & 84"R & SH @ 42" & 84"12/4 x 6/8R.O. 2' -6" x 6' -11"PRIMARYCLOSET48" TALL WALL W/GLASS PANEL12/4 x 6/8R.O. 2' -6" x 6' -11"HOOK WALL R & SH @ 68"5-SHELVESCLOSETLAUNDRYBATH12/4 x 6/8R.O. 2' -6" x 6' -11"16" SH.9" SH.(5)12/4 x 6/8R.O. 2' -6" x 6' -11"5'-9" VANITY -TALLLINEN5' TUB/SHWR2x6CLOSETBATH6' - 0"7' - 0"3' - 11 1/2"5' - 4 1/2"2' - 3"6' - 1"10' - 4"3' - 10"6' - 2"8' - 0"3' - 0"19' - 0"19' - 0"6' - 0"4' - 0"2' - 8"49' - 0"38' - 0"38' - 0"STORAGE2-2x102-2x10 2-2x6 EA. SIDE 2-2x10 GIRDER TRUSS42/6 x 6/8R.O. 2' -8" x 6' -11"32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"2x65' TUB/SHWR12/4 x 6/8R.O. 2' -6" x 6' -11"13' - 0"6' - 0"R & SH @ 68"12/4 x 6/8R.O. 2' -6" x 6' -11"L.T.CLOSET2-2x102-2x103-2x63-2x62-2x104-2x6TILECURB32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"48" LINEN2' - 6"2x6 KNEE WALL W/14" PAINTEDSPINDLES CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESMFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.SMOKEDET.CO DET.118050E NVGER.O. 8' -0" x 5' -0"H.H. 6' -10"96020 NVFA3R.O. 6' -0" x 2' -0"H.H. 6' -10"43050E NVC1R.O. 3' -0" x 5' -0"H.H. 6' -10"33020 NVPWGR.O. 3' -0" x 2' -0"H.H. 6' -10"85040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"4522626 NVFA1R.O. 2' -6" x 2' -6"H.H. 6' -10"53350E NVH1R.O. 3' -3" x 5' -0"H.H. 6' -10"B.W.P.4' - 0"B.W.P.2' - 8"B.W.P.2' - 8"R & SH @ 68"SPRAY FAOM SMOKEDET.0' - 9"0' - 6"4:12 ELONGATED DRYERWASHER4' - 7"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:10/18/2023 3:00:02 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-404OTT40710.18.23 CB16111539119110.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKE1/4" = 1'-0"A-4041UPPER FLOOR PLANOKOKOKOKOKOKOKOKOK||[][]||[]][]|[][||]||[||OK||||*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***
6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANS1' - 6"2x4 TYP.2x42x4 @ TOPSOFFITFRONTSIDETOP VIEWSMOOTHSMARTSIDETYPICAL4x4 POSTFRAMING1' - 6"1' - 6"1' - 6"1' - 3"1' - 3"1' - 8"1' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGS9' - 1 1/8"6' - 8"R=1'-7"3' - 0"1' - 4"ALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSSWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER FLOOR PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATIONSTANDARD ENERGY HEELS @ 8:12 W/10:12 FASCIA LINES TO MATCH 18" OVERHANGS & 12" RAKES TYP. 8 ROOF VENTS REQUIRED STANDARD ENERGY HEELS @ 5:12 W/ 7:12, 8:12 & 10:12 FASCIA LINES TO MATCH 5:12 RAISED HEEL2 ROOF VENTS REQUIRED 1 ROOF VENT REQUIRED 8" / 12"8" / 12"7" / 12"7" / 12"5" / 12"8" / 12"8" / 12"10" / 12"10" / 12"10" / 12"10" / 12"5" / 12"10" / 12"10" / 12"5" / 12"8" / 12"THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:10/18/2023 3:00:04 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-501OTT40710.18.23 CB16111539119110.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKE1/2" = 1'-0"A-5011TYP. POURED WALKOUT SECTION1/2" = 1'-0"A-5012TYP. POURED LOOKOUT SECTION1/2" = 1'-0"A-5013TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5014TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5015TYP. COLUMN1/2" = 1'-0"A-5017BEARING WALL SECTION1/2" = 1'-0"A-5018ARCH DETAIL1/2" = 1'-0"A-5019GARAGE CEILING3/8" = 1'-0"A-50110TYP. POURED WALL SECTION1/8" = 1'-0"A-50111ROOF PLANWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT COMMENTS1 VECTOR ENVISION SERIES 1 2036 NVH1 2' - 0" 3' - 6" 12' - 9 3/4"2 VECTOR ENVISION SERIES 1 2626 NVFA1 2' - 6" 2' - 6" 6' - 10"3 VECTOR ENVISION SERIES 1 3020 NVPWG 3' - 0" 2' - 0" 6' - 10" OBSCURE GLASS4 VECTOR ENVISION SERIES 2 3050E NVC1 3' - 0" 5' - 0" 6' - 10"5 VECTOR ENVISION SERIES 4 3350E NVH1 3' - 3" 5' - 0" 6' - 10"6 VECTOR ENVISION SERIES 1 3636 NVG1 3' - 6" 3' - 6" 6' - 10"7 VECTOR ENVISION SERIES 7 3650 NVPWG/3620 NVA1 TEMP. 3' - 6" 6' - 11 1/2" 8' - 0"8 VECTOR ENVISION SERIES 3 5040E NVG1 5' - 0" 4' - 0" 6' - 10"9 VECTOR ENVISION SERIES 1 6020 NVFA3 6' - 0" 2' - 0" 6' - 10"10 VECTOR ENVISION SERIES 1 8040E NVGE 8' - 0" 4' - 0" 6' - 10"11 VECTOR ENVISION SERIES 1 8050E NVGE 8' - 0" 5' - 0" 6' - 10"ROOM FINISH SCHEDULEFLOOR ROOM NAME AREA FLOOR FINISH CEILING HEIGHT COMMENTSLOWER FLOOR MECHANICAL 208 SF 8' - 2"LOWER FLOOR BEDROOM #5 158 SF CARPET 8' - 2" .LOWER FLOOR FAMILY ROOM 596 SF CARPET 8' - 2" .LOWER FLOOR GAME ROOM 181 SF CARPET 8' - 2" .LOWER FLOOR CLOSET 48 SF CARPET 8' - 2"LOWER FLOOR BATH 68 SF VINYL 8' - 2" .MAIN FLOOR PANTRY 42 SF 9' - 1 1/8"MAIN FLOOR GREAT ROOM 287 SF CARPET 10' - 1 1/8" 10'-1 1/8" PLATE HEIGHTMAIN FLOOR OFFICE 121 SF CARPET 9' - 1 1/8" .MAIN FLOOR PORCH 164 SF CONCRETE 9' - 1 1/8" .MAIN FLOOR GARAGE 663 SF CONCRETE 10' - 9 3/8"MAIN FLOOR CLOSET 43 SF VINYL 9' - 1 1/8" .MAIN FLOOR POWDER 27 SF VINYL 9' - 1 1/8" .MAIN FLOOR MUD RM. 79 SF VINYL 9' - 1 1/8" .MAIN FLOOR DINING 177 SF WOOD 9' - 1 1/8" .MAIN FLOOR KITCHEN 384 SF WOOD 9' - 1 1/8" .MAIN FLOOR FOYER 153 SF WOOD 9' - 1 1/8" .UPPER FLOOR PRIMARY SUITE 246 SF CARPET 8' - 1 1/8" VAULTEDUPPER FLOOR BEDROOM #3 139 SF CARPET 8' - 1 1/8" .UPPER FLOOR HALL 143 SF CARPET 8' - 1 1/8"UPPER FLOOR BEDROOM #4 168 SF CARPET 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 175 SF CARPET 8' - 1 1/8" .UPPER FLOOR PRIMARY CLOSET 78 SF CARPET 8' - 1 1/8" .UPPER FLOOR CLOSET 27 SF CARPET 8' - 1 1/8" .UPPER FLOOR CLOSET 29 SF CARPET 8' - 1 1/8" .UPPER FLOOR STORAGE 20 SF CARPET 8' - 1 1/8" .UPPER FLOOR CLOSET 21 SF CARPET 8' - 1 1/8"UPPER FLOOR EN SUITE 140 SF TILE 8' - 1 1/8" .UPPER FLOOR LAUNDRY 55 SF TILE 8' - 1 1/8" .UPPER FLOOR BATH 48 SF VINYL 8' - 1 1/8" .UPPER FLOOR BATH 56 SF VINYL 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE Rough Width Rough Height COUNT COMMENTS1 2/4 x 6/8 2' - 6" 6' - 11" 132 2/4 x 6/8 ARCH 13 2/4 x 6/8 PKT 4' - 10" 6' - 11" 34 2/6 x 6/8 2' - 8" 6' - 11" 45 2/6 x 6/8 PKT 5' - 2" 6' - 11" 16 2/8 x 6/8 2' - 10" 6' - 11" 47 2/8 x 6/8 2' - 10" 6' - 10 1/4" 18 3/0 x 6/8 ARCH 19 3/0 x 6/8 W/ 2-12" D.S. S.L.'S STEEL 110 5/0 x 6/8 FULL VIEW 5' - 2" 6' - 11" 111 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 212 8' x 8' O.H. GARAGE DOOR 113 16' x 8' O.H. GARAGE DOOR 1
FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP. FASTENKING STUD TO HEADERW/ 6-16d SINKERS.MIN. 7/16" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).FRONT ELEVATIONMIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 7/16" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INFRAMING (STUDS AND SILLS) AS SHOWN TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALEXTENT OF HEADER WITH DOUBLE PORTAL FRAMES (TWO BRACED WALL PANELS)BRACED WALL LINECONTINUOUSLYSHEATHED WITH WOODSTRUCTURAL PANELS.OVERLAP0' - 9 1/4" MIN.WOOD STRUCTURAL PANEL SHEATHINGCONTINUOUS OVER BAND OR RIM JOISTNAIL SOLE PLATE TO JOISTPER TABLE R602.3(1)WOOD STRUCTURAL PANEL SHEATHING OVER APPROVED BAND OR RIM JOISTATTACH SHEATHING TOBAND OR RIM JOIST WITH8d COMMON NAILS @3" O.C. TOP @ BOTTOMFASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (612) 327-7582NORTHHOUSE-RD.COMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONBRAINERD LAKESTWIN CITIES3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:10/18/2023 3:00:06 PMTHE YOCKEY RESIDENCEL34, B1 -PHEASANT RUN 7TH ADD'N17700 ELLSWORTH DRIVELAKEVILLE, MN 55044A-502OTT40710.18.23 CB16111539119110.17.23 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4341THE BROOKE3/8" = 1'-0"A-5021METHOD CS-PF - RAISED WOOD W/ OVERLAP3/8" = 1'-0"A-5022METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:
Date Certificate Posted
X Passive (No Fan)
Active (With fan and monometer
or other system monitoring
device)
Location (or future location) of Fan:
Other Please Describe Here
R-15 X
R-20 X
R-20 X
R-20 X
R-49 X
R-49 X
R-30 X
R-30 X
X Not applicable, all ducts located in conditioned space
X Not required per mech. code
Passive
Powered
Interlocked with exhaust device.
Describe:
Input in
BTUS:
90,000 Capacity
in Gallons:
Other, describe:
AFUE or
HSPF%
93
Cfm's
" round duct OR
" metal duct
Not required per mech. code
X Passive
Low: Other, describe:
X Low:
Location of fan(s), describe: Cfm's
X " round duct OR 7" flex
" metal duct
City Mailing Address of the Dwelling or Dwelling Unit
Combustion Air Select a Type
Location of duct or system:
3
Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.11/7/2023
New Construction Energy Code Compliance Certificate
Name of Residential Contractor
One Ten Ten Homes, LLC
MN License Number
Lakeville17700 Ellsworth Drive
BC730925
Mechanical room
Heat Recover Ventilator (HRV) Capacity in cfms:
Energy Recover Ventilator (ERV) Capacity in cfms:
75702
Heating Gain Cooling Load
90
Fuel Type
Solar Heat Gain Coefficient (SHGC):
Windows & Doors
Ceiling, vaulted
Bay Windows or cantilevered areas
Floors over unconditioned area
Rim Joist (2nd Floor+)
0.28
Appliances
THERMAL ENVELOPE
Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade
RADON CONTROL SYSTEM
Non or Not Applicable Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply
Mineral Fiberboard Insulation Location
Foam, Closed Cell0.21
Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall
R-value
Average U-Factor (excludes skylights and one door ) U:
Duct system air tightness: Building envelope air tightness:
Rim Joist (1st Floor)
GPVL5000L 13ACX036P Model
Heating System
Natural Gas
Lennox
Location of duct or system:
Heating or Cooling Ducts Outside Conditioned Spaces
Electric
Make-up Air Select a Type
AO Smith
Domestic Water
Heater
MECHANICAL SYSTEMS
Rating or Size
Efficiency
13
180
Select Type
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
33347Residential Load Calculation
SEER
/EER
Total ventilation (intermittent + continuous) rate in cfms:
Balanced Ventilation capacity in cfms:
High:
High:
MECHANICAL VENTILATION SYSTEM
Capacity continuous ventilation rate in cfms:
ML19309016C
Heating Loss
Manufacturer Lennox
Natural Gas
Output
in Tons:
350
Builders Associaton of Minnesota version 101014
NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION
This form must be completed and submitted with all new residential permit applications.
New residential building permits WILL NOT be issued without this completed form.
Project Site Address: _____________________________________________________________________
Company Name: _________________________________________________________________________
Primary Contact: _________________________________________________________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Description of Land Disturbing Activity: _____________________________________________________
NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___
If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an
erosion and sediment control plan MUST be submitted with the residential building permit application.
Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control
inspections and corrective actions:
Name of Person: ________________________________Company: _______________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Entity that Provided Training: ________________________ Certification Expiration Date: ____________
NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots.
No land disturbing activity may begin until a residential building permit has been issued.
I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National
Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER;
withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater
Permit (MN R 100001) or erosion and sediment control plan.
Signature: ________________________________________________ Date:_________________________
Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500
* If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to
erosion@lakevillemn.gov
“The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA)
“The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA)
11/15/23 X
PM