Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA221118 - 20158 Gambrel Path-Permit Pack
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND EV1F CORDOBA-2 CAR 20158 Gambrel Path Cedar Hills-2nd Addition549 SFConcept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode01/05/2024jnuetzman SCALE:A1.11FRONT ELEVATION1/4" = 1'- 0"SCALE:A1.12ROOF PLAN1/8" = 1'- 0"SCALE:A1.13SIDE ELEVATION1/8" = 1'- 0"SCALE:A1.14SIDE ELEVATION1/8" = 1'- 0"SCALE:A1.15REAR ELEVATION-LOOKOUT 1/8" = 1'- 0"SCALE:A1.15AREAR ELEVATION-WALKOUT1/8" = 1'- 0"SCALE:A1.11ACOLUMN DETAIL1/2" = 1'- 0"GARAGE HARDWARE PERCOMMUNITY SPECSEXTERIOR MATERIALS % LAP SIDING = 13% STONE = 37% SHAKE = 40% TRIM = 10%LP SHAKE SIDINGFACE APPLIED STONE VENEERLP HORIZONTAL LAP SIDINGHARDBOARD SIDING ON FRONT ELEVATION.FACE APPLIED STONE VENEERHARDBOARD SIDING ON SIDE AND REAR ELEVATIONS.LP HORIZONTAL LAP SIDINGSecure door closed until deck isconstructed with a separate permit. W.H.TANKLESS1/2" ROCK, 8" DEEP20" x 8" CONC. FTG.W/ SILL SEALER(TR) 2x6 SILL PLATEGRADER-20 BATT INSUL.BOLT AT 72" O.C.1/2" DIA. x 10" ANCHOR8" W. POURED CONC.FOUNDATION WALL CONC. SLABPER PLANEXT. FIN. PER PLANDOUBLE TOP PLATEHEADER AT WIN.4 MIL POLY8"2"WRB PER PLAN FLR. SYSTEMVAPOR BARRIERR-10 RIGID INSUL.OR APPROV. STRAP42" MIN.WATERPROOFINGREQ'D. @ TOP OFFDN. WALLR-20 INSUL. @ RIMRIM BOARD6" MIN.1/2" EXT. SHEATHINGCONC. SLAB20" x 8" CONC. FOOTINGFOUNDATION WALLDOUBLE TOP PLATEPER PLANFLR. SYSTEM8" W. POURED CONC.1/2" DIA. x 10" ANCHORBOLT AT 72" O.C.R-20 BATT INSUL.2x8 (TR.) SILL PLATEW/ SILL SEALERGRADEOR APPROV. STRAP3'-6"R-20 SPRAY FOAM INSUL.RIM BOARDR-10 EXT. FDN. INSUL.R-5 RIGIDINSULATIONWATERPROOFINGTOP OF FDN. WALLCANT PLATE 1 1/2"SQUASH BLOCKS@ ALL POINT LOADS2x8 STUDS @ 16" O.C.SIDE WALLWALKOUTFDN. ONLY4" WEEPS EVERY 6'WATERPROOFING6" MIN.1/2" ROCK, 8" DEEPEXT. FIN. PER PLANWRB 1/2" EXT. SHEATHINGAT FOUNDATION4" D. x 8" H. LEDGEPER PLANSUBFLOORFLOOR SYSTEMRIM BOARDCONC. STOOP7 3/4" ENTRY DR. MAX. TO10"30 MIL PVC MEMBRANESEAL ALL SEAMS,CORNERS & EDGES W/35 MIL POLYETHYLENEBACKED SYNTHETICBUTYL RUBBERADHESIVE MEMBRANE1/2" SHEATHING(2") R-10 EXTERIORR-20 SPRAY FOAM INSUL.WATERPROOFINGREQ'D.@ TOP FDN.FOUNDATION INSULATION2x8 SILL PLATEW/ ANCHOR BOLTS1 1/2" CANT'D. ALIGN W/ FDN. WALLTHRESHOLD SUBFLOORFLOOR JSTS/TRUSSES20"x8" CONC. 2x6 TOP PLATECONC. SLABPER PLANPER PLAN16" O.C. (TYP)2x6 STUDS @2x6 TREATEDPLATESECURED W/POWDEREDACTUATEDFASTENERS@ 24" O.C.1"4"x1/2" TRT'D.PLYWOOD,HOLD UP 1"FROM FTG.EACH SIDEBY ENGINEERFTG. U.N.O.4" CONC. SLABFLOOR SYSTEMGARAGE SLAB SLOPE: 4"20" x 8" CONC. FOOTINGPER PLAN20" x 8" CONC. FOOTING8"PER PLANWATERPROOFINGB.O. FTG.GRADE3'-6" MIN.VAPOR BARRIER8" GRANULAR FILL4" CONC. SLABTOP OF CURBTOP OF FDN.TREATED 2x SILLPLATE W/ SILL SEALERSHEATHINGEXT. MTR'L. PER PLANRIM BOARD (BY MFG.)5/8" GYP. SHEATHINGR-10 EXTERIOR FDN.INSULATION10"6"4"2" CERTI-STUD ATFOUNDATION LEDGER-20 SPRAY FOAMINSULATIONWATERPROOFINGREQ'D. AT TOP OFFOUNDATION WALL2x6 SILL PLATEW/ ANCHOR BOLT / STRAPNO CANT. AT GARAGESTD. RIM DETAILHOUSE BASELINE DIM.GAR. OUT TO OUT DIM.NOTE: NO R-5 INSUL.REQ'D. AT GAR./HOUSEINT. COMMON WALLS4" WEEPS EVERY 6'4"(PLATE SIZE PER PLAN)6"MIN.NOTE:FOUNDATION SHALL EXTENDABOVE THE FINISHED GRADEADJACENT TO THE FOUNDATIONAT ALL POINTS AT LEAST 6"FOUNDATION NOTES:·MAXIMUM WALL LENGTH WITHOUT A CONTROL JOINT TO BE 50'-0·PRIOR TO BACKFILLING, FOUNDATION WALLS MUST BE LATERALLY SUPPORTED BY FLOORCONSTRUCTION AT BOTH TOP & BOTTOM OR BY ADEQUATE TEMPORARY BRACING·WALLS WITH EQUAL BACKFILL ON BOTH SIDES REQUIRE NO REINFORCING FOR WALLLENGTHS LESS THAN 25'-0" LONG AND HORIZONTAL REINFORCING ONLY FOR WALLSLONGER THAN 25'-0"·EXTERIOR WATERPROOFING SHALL COMPLY W/ R406.2 PER 2020 MN RESIDENTIAL CODE,WATERPROOFING SHALL EXTEND FROM TOP OF INSIDE EDGE, ACROSS TOP AND DOWNEXTERIOR FACE OF FOUNDATION WALL TO FOOTING·EXTERIOR FIBERBOARD INSULATION TO BE APPLIED OVER WATERPROOFING. ABOVEGRADE TO BE 2" THICK R-10 CERTISTUD OR EQUAL TO ALLOW FOR SIDING APPLICATION.BELOW GRADE TO BE R-10, 2 3/8" THICK FIBERBOARD (WATCHDOG OR EQUAL). SILLPLATE TO OVERHANG FOUNDATION BY 1 1/2" TO ALIGN FOUNDATION INSULATION WITH1/2" SHEATHING ABOVE. A GROUND BREAKER PRODUCT WILL BE USED TO TRANSITIONFINAL GRADE TO SIDING MATERIAL·2x8 STUD FRAMED WALLS AT LOOKOUT REAR/SIDE RETURNS AND WALKOUT SIDERETURNS·ALL INTERIOR WALLS ARE 3 1/2", UNLESS NOTED OTHERWISE·ALL POINT LOAD SUPPORTS (JACK STUDS) TO BE CARRIED THRU EACH FLOOR LEVEL TOBEAR ON FOUNDATION, INSTALL BLOCKING IN FLOOR SYSTEM BELOW ALL POINT LOADSUPPORTS·ALL WOOD IN CONTACT W/ CONCRETE TO BE PRESSURE TREATED WOOD·DISTANCE FROM T.O. FOOTING TO T.O. FOUNDATION WALL TO BE 8'-4" FOR 8' BASEMENT·EXPOSED FLOOR SYSTEM ABOVE UNFINISHED AREAS TO MEET R501.3 FIRE PROTECTIONREQUIREMENTS·FLOOR TRUSS FLOOR SYSTEM, SEE TRUSS LAYOUTS FOR SIZE & SPACING REQUIREMENTSTREATED 2x10BACK TO ALLOW HOLD FNDTN. WALLFOR 2x BLOCKING8"8"SCALE:A2.11FOUNDATION PLAN1/4" = 1'- 0"SCALE:A2.11AFOUNDATION PLAN - WALKOUT1/4" = 1'- 0"SCALE:A2.13WALKOUT DETAIL3/4" = 1'- 0"SCALE:A2.16DETAIL AT STOOP3/4" = 1'- 0"SCALE:A2.12LOOKOUT DETAIL3/4" = 1'- 0"SCALE:A2.15BEARING WALL3/4" = 1'- 0"SCALE:A2.14NON-DROP'D GARAGE/COMMON WALL3/4" = 1'- 0"SCALE:A2.17FND. REAR WALL CORNER DTL.3/4" = 1'- 0"UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. NOTE:WINDOW FALL PROTECTION TO BE PROVIDEDIN ACCORDANCE WITH R312.2GENERAL NOTES:·FIRST FLOOR CEILINGS TO BE 9'-1 1/8" ROUGH CEILING HEIGHT (U.N.O.)·T.O. FIRST FLOOR WINDOWS TO BE FRAMED AT 7'-11" (U.N.O.)·SECOND FLOOR CEILINGS TO BE 8'-1 1/8" ROUGH CEILING HEIGHT (U.N.O.)·T.O. SECOND FLOOR WINDOWS TO BE FRAMED AT 6'-11" (U.N.O.)·ALL EXTERIOR HOUSE WALLS TO BE 2x6 @ 16" O.C. (U.N.O.)·GARAGE/HOUSE COMMON WALLS TO BE 2x6 @ 16" O.C. (U.N.0.)·GARAGE WALLS TO BE 2x4 @ 16" O.C. (U.N.O.)·INSTALL 5/8" FIRECODE GYPSUM BOARD ON ALL GARAGE CEILINGS AND ADJOININGHOUSE WALLS·ALL INTERIOR HOUSE WALLS TO HAVE 1/2" GYPSUM BOARD, ALL HOUSE CEILINGS TOHAVE 5/8" FIRECODE GYPSUM BOARD·INTERIOR WALLS TO BE 2x4, WITH EXCEPTION TO THE 2x6 PLUMBING & BEARING WALLSPER PLAN (U.N.O.) ALL INTERIOR WALLS FRAMED @ 16" O.C.·ALL ANGLED WALLS ARE 45 DEGREES (U.N.O.)·ALL POINT LOAD SUPPORTS (JACK STUDS) TO BE CARRIED THRU EACH FLOOR LEVELTO BEAR ON FOUNDATION, INSTALL BLOCKING IN FLOOR SYSTEM BELOW ALL POINTLOAD SUPPORTS·ALL WOOD IN CONTACT W/ CONCRETE TO BE PRESSURE TREATED WOOD·ALL DIMENSIONS ARE TO ROUGH FRAME (U.N.O.)·S.R.O. SIZES LISTED ARE THE FINISHED SHEETROCK OPENING WIDTH AND HEIGHT PERPLAN (EXAMPLE: 2680 OR 2/6x8/0 = 2'-6"x8'-0")·FLOOR BREAK INDICATES CHANGE IN FLOORING MATERIAL, REFER TO THESPECIFICATIONS FOR ACTUAL FLOORING MATERIALS SELECTED·REFER TO SPECIFICATION INFORMATION FOR ALL APPLIANCES & THE APPROPRIATEELECTRICAL OR GAS HOOK-UP REQUIREMENTS FOR EACH·REFER TO SPECIFICATION INFORMATION FOR ALL TUB AND SHOWER SURROUNDMATERIALS·REFER TO SPECIFICATION INFORMATION & CABINET SHOP DRAWINGS FOR KITCHEN &BATH CABINET LAYOUT, SIZES & FEATURES PER CABINET SUPPLIER·ALL BATHROOM FANS TO BE VENTED TO EXTERIOR·TOWEL BARS MOUNTED AT 54" AFF, TOILET PAPER HOLDERS MOUNTED AT 24" AFF·ALL PANTRY & LINEN CLST'S. TO RECEIVE WIRE SHELVING, (U.N.O.)·ALL CLOSETS TO RECEIVE (1) ROD & (1) WIRE SHELF (U.N.O.)·ALL WASHERS ON LEFT SIDE, ALL DRYERS ON RIGHT SIDE·AT ALL BATHROOM VANITIES, INSTALL WOOD STUD FRAMING SO ELECTRICAL OUTLETIS CENTERED ON VANITY.SCALE:3.11FIRST FLOOR PLAN1/4" = 1'- 0"SCALE:3.12GOURMET KITCHEN OPTION1/4" = 1'- 0"SCALE:3.13TILED SHOWER W/ BENCH OPTION1/4" = 1'- 0"-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). LENNAR WILL INSTALL A "PASSIVE RADON READY" SYSTEM. ALL BASEMENT SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY 6 MIL POLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS OR PUNCTURES WILL BE SEALED OR COVERED BY POLY. ALL OPENINGS WILL BE SEALED USING POLYURETHANE CAULK OR ELASTOMERIC SEALANT AT ALL OPENINGS. ALL SUMP BASKETS WILL HAVE SEALED LIDS. LENNAR WILL INSTALL A 3" GASTIGHT PVC PIPE, AND WILL BE CONNECTED TO THE DRAIN TILE SYSTEM. USING A "T" FITTING, INTO THE DRAIN TILE SYSTEM. WE WILL USE THE SHORTEST ROUTE TO EXIT THE ROOF SYSTEM, WITH A MAX. OF (2) 90 DEGREE ELBOWS. IN UNCONDITIONED AREAS, THE RADON EXHAUST PIPE WILL BE INSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED "RADON GAS VENT SYSTEM" AT ALL ACCESSIBLE LOCATIONS. ALSO, ALL RADON PIPES WILL BE LABELED AT ALL FLOORS FOR FUTURE REFERENCE. AT ROOF EXIT LOCATIONS, WE WILL MAINTAIN A 10' DISTANCE TO ANY WINDOW LOCATION, 2' BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THE LOCATION OF THE EXIT POINT, IN TRUSS AREA, WILL BE CLEAR OF ANY OBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36" VERTICALLY. LENNAR WILL INSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUST FAN ADDITION. RADON NOTE: 18" FLOOR TRUSS 25/32" OSB SUBFL. BOTTOM OF TOP CHORD VAPOR BARRIER R-44 BLOWN INSULATION EXTEND SHTG. TO 5/8" DRYWALL CLG. (TYP.) CEILING (WINDWASH) MANUF. TRUSSES 24" O.C. 12 PER PLAN BATT INSULATION (R-20 MIN.) 2x6 TOP & BOTTOM PLATES 1/2" DRYWALL WALLS W/ 4 MIL. POLY (TYP.) 7/16" OSB SHEATHING, TYP. VAPOR BARRIER 2x6 STUDS 16" O.C. WALL CONST. SIDING PER SPEC. LEVEL HOUSE WRAP ROOF CONST. ASPHALT SHINGLES PER SPECS. WATERGUARD ICE BARRIER AT EAVES SOFFIT AND FASCIA PER SPEC. LEVEL 7/16" OSB SHEATHING INSULATION CHUTES 15# FELT 2x6 SUBFASCIA RIM CONST. - R-20 MIN. 2x8 TR. SILL PLATE W/ A.B. (SEE SHT. S2) R-20 SPRAY FOAM INSULATION 7/16" OSB SHEATHING (CANT. PLATE 1 1/2" TO ALIGN W/ 1/2" INSIDE SHEATHING) 2" CERTI-STUD INSUL (R-10) WINDOW FALL PROTECTION ALL WINDOWS, WITH SILLS BELOW 36" A.F.F. AND 72" AT REAR WALL (LOOKOUT / WALKOUT) TO RECEIVE FALL PROTECTION, ABOVE YARD GRADE PER R312.2.1 STD. ENERGYHEEL HT.MIN. 6"6" GRAVEL FILL 6 MIL POLY / LAPPED 12" 4" CONCRETE SLAB 20x8 CONC. FTG. APPROX. GRADE 8" POURED CONC. WALL FDN. WALL CONST. "WATCH DOG" WATERPROOFING 2 3/8" "WATCHDOG" (R-10) XP BOARD TO GRADE INTERIOR R-5 RIGID INSULATION 7/16" OSB SHEATHING TYP. BATT INSULATION (R-20 MIN.) 2x8 TOP & BOTTOM PLATES HOUSE WRAP VAPOR BARRIER 2x8 STUDS 16" O.C. (LOOKOUT ONLY) WALL CONST. SIDING PER SPEC. LEVEL WALKOUT WALL DETAIL SEE PAGE A2 FOR NOTE: HOUSE WRAP CUTTING PATTERN 1 2 CUT HOUSE WRAP PER DIAGRAM. CUT UPPER FLAP AT 45 FLEX WRAP WINDOW OPENING WRAP TO SILL OF APPLY 10" FLEX UNDER HEAD INSTALL WINDOW INSTALL JAMB STRIPS OVER INSTALLED WINDOW HOUSE WRAP FOLD HOUSE WRAP FOLD STRIP UNDER UPPER INSTALL HEAD UPPER FOLD AND TAPE OVERCUT OVER HEAD STRIP DROP UPPER FOLD TO SETTING WINDOW APPY CAULK BEHIND WINDOW FINS PRIOR HOLD UPPER FOLD OUT UNTIL FINAL STEP INSTALL, FOLD SIDE AFTER FLEX WRAP HOUSE WRAP FLAPS OVER FLEX WRAP AND TRIM / FASTEN TAPETAPE WINDOW WRAP.CAP UNDERINSTALL DRIP DOWN EACH SIDE.BEND CORNERS 3 4 5 6 7 8 9 SEAMS SCALE:A4.1 1 TYPICAL WALL SECTION 3/8" = 1'- 0" SCALE:A4.1 3 HOUSE WRAP DETAIL AT WINDOWS 3/8" = 1'- 0" SCALE:A4.1 2A/B SECTION 1/4" = 1'- 0" SCALE:A4.1 2D SECTION 1/4" = 1'- 0" SCALE:A4.1 2C SECTION 1/4" = 1'- 0" HEADER1/2" GYPSUM BD.1/2" GYPSUM BD.WIN. OPNG.2x6 HEADER PLATEINSULATE1 1/4" RIM BOARD2x6 DOUBLE TOP PLATE2x6 SILL PLATESUBFL.INSULATE2" SPRAY6'-11 3/8" TO T.O. WIN. R.O.SUBFL. AT 8' CLG. 8'-0" TO SUBFL. AT 9' CLG.1x2 AT EA. SIDE OFWINDOW OPENINGSHEATHINGFOAM INSUL.FLOOR SYSTEM PER PLAN1/2" GYPSUM BD.TRUSS BTM. CHORDTOP PLATEDOUBLE WIN. OPNG.WIN. HDRS.SHEATHING2x6 HDR. PLATET.O. WIN. R.O.6'-11 3/8" TO SUBFL.INSULATEINT/EXT WALL INTERSECTIONINTERIOR WALL CORNER2x6 EXTERIOR WALL1/2" GYPSUM BOARD2x6 R.W. 2x4 R.W. 2x6 EXTERIOR WALL2x2 R.W. INSIDE CORNEROUTSIDE CORNERINSULATE STUDCAVITIES OF ALLCORNERS AND INTERSECTIONSOF OUTSIDE WALLSSIDING2x4 INTERIOR WALL 2x4 BACKINGAT MID HGT.2x4 INT. WALLSHEATHING(EXT. FIN. MAY VARY PER PLAN)PER PLANEXT. MAY VARYSHEATHING9'-0"PLYWD.ALUM. SOFFITW/ALUM.2 x 6 SPF1/2" OXBOARD SHEATHINGGABLEEND TRUSS(WHERE APPL.)2x6 FOR LOOK OUTSUSE SCRAP 2x4 ORNOTE:ENG'DFASCIADIM.2x4 INT. WALLBOARD1/2" GYPSUM5/8" GYPSUM BD.2x4 DOUBLETOP PLATE2x6 BACKINGBOTTOM CHORDOF TRUSSINT WALL2x2 NAILER3/4" PLYWOOD1/2" GYP. BD.FIRE STOP5/8" GYP. BD.I-JOISTDOUBLE TOP PLATEPER PLAN5/8" GYP. BD.1/2" GYP. BD.PER PLANHANGER(2) MICROLAM BEAMSHANGER1/2" GYPSUM BD.SUBFLOORNOTE:FOLLOW MFG'S NAILINGPATTERN FOR HANGERFLOORSYSTEMPER PLANFLOORSYSTEMPER PLANFLOOR SYSTEM PER PLAN1/2" GYPSUM BD.SUBFLOOR(2) 2 x HEADERS1/2" OSBDOUBLE TOP PLATESILL PLATESILL/ TILT TO OUTSIDEHEADER(1) 2X6 TRIMMER U.N.O. VARIES8'-1 1/8" or 9'-1 1/8" TYPICALVARIES7'-0" OR 8'-0" (MAIN FLOOR) / 6'-11 3/8" (2ND FLR.)(R.O.)(R.O.)ON FLOOR PLAN(REFER TO PLAN)FOR WATER DRAINAGERUN TRIMMERS TOBOTTOM OF HEADER(SEE PLAN)BOTT. PL.10"2x12 STRINGERS3'-0"10"7 3/4" MAX.(3) 2x12 STRINGERS5/8" TYPE "X" GYP.AT ENCLOSED USABLESPACE (TYPICAL)UNLESS NOTED OTHERWISE IN CONSTR. WORK ORDERPARTICLE BOARD TREADS & RISERS3"6 1/2" W. x 3/4" T.WOOD CAP5/8" TYPE "X" GYP.AT ENCLOSED USABLESPACE (TYPICAL)ALLOW 6'-8" MIN. HEADROOMNOTE:REFER TO SELECTIONS FOR REFER TO PLAN OR WORK ORDER FOR RAIL AND FINISH TYPE(S)NOTE: THIS DETAIL IS FOR FRAMING PURPOSES ONLY4"MAX.RAIL TYPE3/4" PLYWOOD1 1/4" RIMBOARDSUBFLOORFACE OF RISER3/4" PLYWOOD1 14"7 3/4" MAX.11 14"FLOORSYSTEMPER PLANMAX.MAX.1 14"11 14"MAX.MAX.2x4 TO EXTEND 1 1/2"BEYOND 2x AT EA. ENDCAULKNOTE:5 DEG.2 x W/BEV. TOP"Z" FLASHINGSMOOTH FINISH 2x4EXT. FINISH PER PLANSEE PLANVARIESROUGH OPENINGROUGH OPENINGSUBFLOORCRIPPLEHEADER PLATEDOUBLE TOP PLATE9'-1 1/8" OR 8'-1 1/8" TYPICAL STUDSNOTE: THIS DETAIL IS FOR FRAMINGPURPOSES ONLY, REFER TO SPEC'S. BOX NEWELSTARTER1 3/4" RIM BD.1/2" GYP.SUBFLR.PER PLANFLR. SYSTEM3'-0" FROM FIN. FLR.FOR RAIL & FINISH TYPES TREADPOSTSTONE CAPOR ROWLOCK BRICKFLASHING - CONT.CAULKSHEATHING15# FELT1" AIR SPACESTUD WALLSIDING PER PLANSLOPED TO DRAINSHEATHING ONCEDAR 5/4x BLOW UP DETAIL1 1/8"CAULK"Z" FLASHING"Z" FLASHING4"MINIMUM FINISH MTR'L.PER PLANPER PLANCAULK2x6 FRAMINGFINISH MTR'L.PER PLANWATER RESISTIVE BARRIERWIN. UNIT DIM.14"WIN. ROUGH OPENINGSHEATHINGWINDOW UNITGYPSUMSPRAY FOAM SIDINGTRANS.INSULATIONTRIMSTONE/BRICK CAPSLOPED TO DRAIN(FOR STONE CAP)CAULKTO BACK OF SILLSHEATHING15# FELT1" AIR SPACEFLASHING - CONT.FLASHING - CONT.(FOR BRICK CAP)TO BACK OF SILL2'-0"2x6 SPF MIN. ICE BARRIERVERT. TO ROOFW/ R20 MIN.2x6 STUD WALLON 4 MIL POLY1/2" GYPSUM BD.SOFFITSIDING PER PLANSHINGLES, 15# FELT, 48# BASESHEATHINGTRUSS BOT. CHORD5/8" GYPSUM BD.INSULATION BAFFLES (48" L.)ENG'D TRUSSES AT 24" O.C.R-49 INSULATIONDBL. TOP PLATEON 4 MIL POLYROOF VENTS AS REQUIREDSHEATHINGICE BARRIER6"MIN.HEEL HGT.ICE BARRIER TO END THIS POINTNOTE: ICE AND WATER SHIELD TO RUNENTIRE LENGTH OF ALL VALLEYS2 ROWS OF 24" TO INSURECOVERAGE PAST PLATE LINEEXTEND SHEATHING1 1/4" PAST END OF TRUSSFOR 6/12 PITCH ROOF.REDUCE OVERLAP PERSTEEPER PITCH TRUSSES.OVERLAP W/ FASCIAICE / WATER SHIELDBATT INS.5/8" FIRE-RATEDGYP. BOARDEXTERIORSHEATHINGWRB CONT. ONVERTICAL &HORIZONTALPLANES ATTUCKUNDER,TAPE ALL SEAMSR-20 SPRAYFOAM AT RIM6" DIA. R-4.2 INSULATEDFLEX-DUCT, HELD TIGHTTO FLOOR ABV.TYP. EXTERIORWALL: 2x6 STUDFRAMING W/ R-21BATT. INSULATIONTHERMOPANR-19 MIN. SPRAYFOAM INSUL.PER TABLE R402.1.1WRB CONTINUOUS ONVERTICAL AND HORIZONTALPLANES AT TUCKUNDER,TAPE ALL SEAMSTUCKUNDER FLOOR CAVITIESW/O HVAC BLOWN FULL W/ 11-7/8"FIBERGLASS L-77 INSULATIONI-JOIST FLRSYSTEMGARAGEHOUSEHOUSEELASTOMERICCAULK ATCORNER(BY INSULATORS)8" MIN.PVC SHOWER PAN LINER,DO NOT CUT, EXTEND UP WALL 8" MIN.CEMENT BOARD, OVER LINERCERAMIC TILEWOOD SUBFLOORGROUT SOLID W/ MORTARCERAMIC TILE, SLOPED1" VERTICAL TO DRAIN2-PIECE SHOWER DRAIN SYSTEMTILE SHOWER WALL & DRAIN DETAILTILE SHOWER PLATFORM DETAILCERAMIC TILE W/ BULLNOSED EDGE AT LIPCEMENT BOARD, OVER LINERWOOD SUBFLOOR(2) 2x4 SLEEPERS AT 8" O.CPVC SHOWER PANLINER, DO NOT CUT.CONTINUE OVERPLATFORM 12" MIN.GROUT SOLID W/ MORTARCERAMIC TILE, SLOPED1" VERT. TO DRAINCERAMIC TILEPLATFORM FLOOR1'-0" MIN.3/4" OSBTILE SHOWER CURB DETAILCEMENT BOARDTILE FLOORWOOD SUBFLOORCERAMIC TILE W/BULLNOSED EDGEBATHROOMSHOWER(2) 2x4 SLEEPERS AT 8" O.C3/4" OSB10"30 MIL PVC MEMBRANE, SEALALL SEAMS, CORNERS & EDGESW/ 35 MIL POLYETHYLENEBACKED SYNTHETIC BUTYLRUBBER ADHESIVE MEMBRANE4" MIN. AT GRADE2" MIN. AT HARD SURFACE W/ NO FOOTERGRADEMORTAR SCRATCH COATEXTERIOR SHEATHINGCULTURED STONE VENEER2 LAYERS WRBWIRE LATHMORTAR SETTING BEDWEEP SCREED, EXTEND MIN. 1" BELOWTOP OF FND. WALL2 LAYERS W.R.B. LAPPEDOVER WEEP SCREEDFRAMING HGT OF BOX PIER PER PLANPER PLAN4"(2) USP B88 CLIPS W/(36" H. MOST COMMON W/ RAILING)FINISH WIDTH IS PER PLAN(6) 3/8" x 1" LAG SCREWSTOP RAIL OF RAILING1/2" OSB SHEATHINGINSTALL ICE/WATER SHEILDBEHIND B88 CLIPS2X6 BACKER AT MID POINTBOTTOM RAIL OF RAILINGINSTALL 2x6, CLIPPEDFOR FLAT CLG. FINISHGYP. BOARD,FINISH PER PLANFLOOR SYSTEMPER PLAN5 12"2x4 STUD WALLNON-BEARINGN/A1FLASHING DETAIL3"= 1'-0"2NAILER DET.1"= 1'-0"3FLUSH BEAM1"= 1'-0"4DROP'D. BEAM1"= 1'-0"5EAVE/RAKE1"= 1'-0"8STONE SILL DETAIL1" = 1'-0"1411M. FLR. WIN. HDR.1" = 1'-0"12UPPER FLR. WIN. HDR.1" = 1'-0"13TYP. STUD LAYOUT1" = 1'-0"15DOOR FRAMING1" = 1'-0"16WINDOW FRAMING1" = 1'-0"19RAIL DETAIL1" = 1'-0"201x2 NAILER @ WINDOW3" = 1'-0"21TRIM DETAIL3" = 1'-0"10PIER W/ RAILING DTL.3/4" = 1'-0"6SOFFIT DETAIL1"= 1'-0"7STONE CAP1"= 1'-0"18STAIR FRAMING DETAILS1/2" = 1'-0"22TYPICAL OVERHANG DETAIL1" = 1'-0"23FLOOR ABV. GARAGE INSUL. DETAIL1" = 1'-0"24SERENITY SHOWER OPTION DETAILS1 1/2" = 1'-0"9STONE VENEER DTL.3/4" = 1'-0"17UNDER FIN. STAIR DTL1" = 1'-0" ELEC. R.I. TOJUNCTION BOX FORFUTURE OUTLETINSIDE CABINETELEC. R.I. TOJUNCTION BOX FORFUTURE OUTLETINSIDE CABINETPMPM W.H.TANKLESSDUPLEX CONVENIENCE OUTLETDUPLEX OUTLET ABOVE COUNTERWEATHERPROOF DUPLEX OUTLETHALF-SWITCHED DUPLEX OUTLETDUPLEX OUTLET IN FLOOR220 VOLT OUTLETWALL SWITCHTHREE-WAY SWITCHFOUR-WAY SWITCHCEILING MOUNTED INCANDESCENT LIGHT FIXTURERECESSED INCANDESCENT LIGHT FIXTURELIGHT FIXTURE WITH PULL CHAINFLOURESCENT LIGHT FIXTUREEXHAUST FANCHIMESSMOKE DETECTORTHERMOSTATELECTRIC PANELPCWPELECTRICAL KEY DUPLEX OUTLET (GROUND FAULT PROTECTED)GFIPRECESSED INCANDESCENT EYE BALL FIXTURECARBON MONOXIDE DETECTORELECTRIC VEHICLE CHARGER ROUGH-IN (OPTIONAL)LED FIXTURELMULTI-MEDIA JACKEVCMMTCMSDCHPLUGMOLD PM34AND HEATING PIPE LOCATIONS AND WOOD FRAMING MEMBERS1. THIS ELECTRICAL PLAN MAY VARY DEPENDING UPON PLUMBINGSUCH AS JOISTS, TRUSSES AND STUDS.GENERAL NOTES ELECTRICAL AND/OR GAS HOOK-UP REQUIREMENTS, THIS INCLUDES2. REFER TO SPECIFICATION INFORMATION FOR ALL APPLIANCEBUT IS NOT LIMITED TO WASHER, DRYER, RANGE/COOKTOP,MICROWAVE, OVEN AND/OR ADVANTIUM (WHERE APPLICABLE),DISHWASHER AND REFRIGERATOR.5. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & RECEPTACLESAT THE FOLLOWING HEIGHTS ABOVE FINISH FLOOR:REQUIREMENTS OF ALL GOVERNING CODES.AS REQUIRED BY NATIONAL ELECTRIC CODE (NEC) AND MEETING THE4. PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERUPTERS (GFI)AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.TELEVISION.........14"TELEPHONE........14"OUTLETS.............14"SWITCHES...........42"AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)3. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORSSCALE:E1.14GOURMET KITCHEN ELECTRICAL1/4" = 1'- 0"SCALE:E1.11FIRST FLOOR PLAN ELECTRICAL1/4" = 1'- 0"SCALE:E1.12UNFINISHED LOWER LEVEL ELECTRICAL PLAN1/4" = 1'- 0"SCALE:E1.13WALKOUT LOWER LEVEL ELECTRICAL PLAN1/4" = 1'- 0" 3'-6" R.O.1'-9 1/2" FRAMEDALLOW 16"SPACE FORVENT DUCT6' - 0 " FI N I S H E D 1'-3"1'-3"4'-3 1/4" TO FRAMING 3'-6" R.OSL-7GAS FIREPLACER.O. 42" W.x 38 1/4" H.x 16 1/4" D.4'-4"8" 5'-0" 512"6'-0" FINISHED9'-0"3'-1" R.O.1x8 SHIPLAPW/ MITEREDCORNERS &RETURNEDBACKTO WALL,PAINTEDWHITE1'-5"FRAMED1'-5"FRAMED4" TRIMHARDIE6" TRIM,PAINTEDWHITE2'-10 1/2"1/2" REVEALAT ALL SIDESOF F.P.1 3/4"SL-7GAS FIREPLACER.O. 42" W.x 38 1/4" H.x 16 1/4" D.4'-4"8" 5'-0" 5 1/2"6'-0" FINISHED9'-0"3'-1" R.O.1'-5"FRAMED1'-5"FRAMED4" TRIM2'-10 1/2"1 3/4"5'-11" FRAMED60"Lx8"Wx8"HWOOD MANTEL,SEE SELECTIONSFOR FINISH:-RUSTIC/DISTRESSED-SMOOTH BOX LIGHT-SMOOTH BOX DARK5'-0" MANTEL1x8 SHIPLAPW/ MITEREDCORNERS &RETURNEDBACKTO WALL,PAINTEDWHITE60"Lx8"Wx8"HWOOD MANTEL,SEE SELECTIONSFOR FINISH:-RUSTIC/DISTRESSED-SMOOTH BOX LIGHT-SMOOTH BOX DARK5'-0" MANTELHARDIE6" TRIM,PAINTEDWHITEFRAME R.O.FOR F.P. BOXAT 6 5/8"ABOVE FLR.1/2" REVEALAT ALL SIDESOF F.P.FRAME R.O.FOR F.P. BOXAT 6 5/8"ABOVE FLR.1'-3 1/2"1/2" GYP. BD.FIREPLACE FLUEFIREPLACE BOX8 1/4"8 1/2" 5 1/2" 1 1/2"3/4"VERIFY DIST. TOCOMBUSTIBLES w/MANUFACTURER'SSPECIFICATIONS.24243/4"3/4"42261x10 TRIMMED2x41x43 1/2"1/2"1x6 241'-0 1/2"1'-8"3'-6"R.O.1'-4"5'-11"ALLOW 16"SPACE FORVENT DUCTFRAMEDFRAMED 1'-8" 1'-10 1/2" FIN.1'-2 1/2"1'-2 1/2"3'-6".R.O.6' - 0 " F I N I S H E D 1'-3"1'-3"8" MANTEL 5'-2"SL-7GAS FIREPLACER.O. 42" W.x 38 1/4" H.x 16 1/4" D.7 1/2"FRAMED912"2'-10 1/2"912" 9'-0"7 1/2"FRAMED912"TO FACE OF GYP. BD.3'-1"2" APPLIEDSTONEVENEER812"5'-11" FRAMED912"TO FACE OF GYP. BD.5'-6" MANTEL1/2"REVEAL ATALL SIDESOF F.P.4'-8"FACE OF GYP. BD.2" STONE RETURN2" STONE RETURN6'-0" FINISHED5'-2"SL-7GAS FIREPLACER.O. 42" W.x 38 1/4" H.x 16 1/4" D.7 1/2"FRAMED9 1/2"2'-10 1/2"9 1/2"7 1/2"FRAMED912"TO FACE OF GYP. BD.3'-1"2" APPLIEDSTONEVENEER8 1/2"5'-11" FRAMED912"TO FACE OF GYP. BD.5'-6" MANTEL6'-0" FINISHED1/2" REVEALAT ALL SIDESOF F.P.4'-3 1/4" FRAMING9'-0" 4"3'-6" R.O.FRAME R.O.FOR F.P. BOXAT 8-7/8"ABOVE FLOORFRAME R.O.FOR F.P. BOXAT 8-7/8"ABOVE FLOOR3'-11"712"712"5'-2"5"5"5 3/4"2'-10 1/4"5 1/4"3'-9 1/4"6'-0"FINISHED5'-10"MANTELINSIDE OF SURROUNDINSIDE OF SURROUNDOUTSIDE OF SURROUND4'-9"5 TILES @ 7-1/8"W/ 1/4" GROUT5 EQ. TILESW/ 1/4" GROUT FRAMED TO CEILINGOUTSIDE OF SURROUNDTILE TO TILETILETILETILE TILESL-7GAS FIREPLACER.O. 42" W.x 38 1/4" H.x 16 1/4" D.3'-11"712"712"5'-2"5"5"5 3/4"2'-10 1/4"5 1/4" 3'-9 1/4"6'-0"FINISHED5'-10"MANTELINSIDE OF SURROUNDINSIDE OF SURROUNDOUTSIDE OF SURROUND4'-9"5 TILES @ 7-1/8"W/ 1/4" GROUTFRAMED TO CEILINGOUTSIDE OF SURROUNDTILE TO TILETILETILETILE TILESL-7GAS FIREPLACER.O. 42" W.x 38 1/4" H.x 16 1/4" D.5 EQ. TILES W/ 1/4" GROUT1'-212"3'-6" R.O.5'-11" FRAMEDFRAME R.O.FOR F.P. BOXAT 4-3/4"ABOVE FLR1'-212"4 7/8" 3'-2 1/4" R.O. 3'-7 1/8"FRAMED TO CEILINGSL-7GAS FIREPLACER.O. 42" W.x 38 1/4" H.x 16 1/4" D.3'-6"1'-5"1'-212"1'-212"5'-11"ALLOW 16"SPACE FORVENT DUCT(FRAMING)(R.O.)(FRAMING)4'-3 1/4" FRAMING3'-6" R.O.6'-0" FINISHED1'-3"1' - 3 "TOP OF MANTELEQ.EQ.8"8"8"8"CLEQ.EQ.CLCEILINGRECEPTACLETECH.TUBE2x10 BLOCKINGBACKER2x4 2x4 2x4 2x4 2x4 3'-6"R.O.1'-4"5'-11"ALLOW 16"SPACE FORVENT DUCTFRAMEDFRAMED 1'-8" 1'-10 1/2" FINISH1'-2 1/2"1'-2 1/2"3' - 6 "R.O.6'-0"FINISHED1'-3"1' - 3 " 4'-3 1/4" TO FRAMING 5'-0"5 1/2"FRAMED9 1/2"2'-10 1/2"8"5'-4" FINISHED9'-0"5 1/2"FRAMED1112"TO FACE OF GYP. BD.3'-1"2" APPLIEDSTONE VENEER5'-0"TO FACE OF GYP. BD.2" STONERETURN2" STONERETURN8"56"Lx8"Wx8"HWOOD MANTEL,SEE SELECTIONSFOR FINISH:-RUSTIC/DISTRESSED-SMOOTH BOX LIGHT-SMOOTH BOX DARK5'-11" FRAMED1112"TO FACE OF GYP. BD.SL-7GAS FIREPLACER.O. 42" W.x 38 1/4" H.x 16 1/4" D.4'-8" MANTEL5'-0"5 1/2"FRAMED9 1/2"2'-10 1/2"8"5'-4" FINISHED9'-0"5 1/2"FRAMED1112"TO FACE OF GYP. BD.3'-1"2" APPLIEDSTONE VENEER5'-0"TO FACE OF GYP. BD.2" STONERETURN2" STONERETURN8"56"Lx8"Wx8"HWOOD MANTEL,SEE SELECTIONSFOR FINISH:-RUSTIC/DISTRESSED-SMOOTH BOX LIGHT-SMOOTH BOX DARK5'-11" FRAMED1112"TO FACE OF GYP. BD.SL-7GAS FIREPLACER.O. 42" W.x 38 1/4" H.x 16 1/4" D.4'-8" MANTEL1/2" REVEALAT ALL SIDESOF F.P.1/2" REVEALAT ALL SIDESOF F.P.5'-0"FRAME R.O.FOR F.P. BOXAT 7-3/8"ABOVE FLRFRAME R.O.FOR F.P. BOXAT 7-3/8"ABOVE FLRPAGE DESCRIPTION:PAGE NO.: PLAN NO. FIREPLACEFIREPLACESFIREPLACES _ 1-10-19 ISSUE FOR CONSTRUCTION 10-12-22 REMOVE FIREPLACE OPTIONS 4, 6 & 7 6-1-2023 Q3 2023 PLAN REVISIONS 09-2023 ADD FIREPLACE FRAMING DETAILS REVISIONS W.H.TANKLESSW.H.TANKLESSW.H.TANKLESSW.H.TANKLESSDUPLEX CONVENIENCE OUTLETDUPLEX OUTLET ABOVE COUNTERWEATHERPROOF DUPLEX OUTLETHALF-SWITCHED DUPLEX OUTLETDUPLEX OUTLET IN FLOOR220 VOLT OUTLETWALL SWITCHTHREE-WAY SWITCHFOUR-WAY SWITCHCEILING MOUNTED INCANDESCENT LIGHT FIXTURERECESSED INCANDESCENT LIGHT FIXTURELIGHT FIXTURE WITH PULL CHAINFLOURESCENT LIGHT FIXTUREEXHAUST FANCHIMESSMOKE DETECTORTHERMOSTATELECTRIC PANELPCWPELECTRICAL KEY DUPLEX OUTLET (GROUND FAULT PROTECTED)GFIPRECESSED INCANDESCENT EYE BALL FIXTURECARBON MONOXIDE DETECTORELECTRIC VEHICLE CHARGER ROUGH-IN (OPTIONAL)LED FIXTURELMULTI-MEDIA JACKEVCMMTCMSDCHPLUGMOLD PM34INT WALL2x2 NAILER3/4" PLYWOOD1/2" GYP. BD.FIRE STOP5/8" GYP. BD.I-JOIST OR 2XDOUBLE TOP PLATEPER PLANPER PLANFOUNDATIONINSULATIONFOUNDATION WALLBETWEEN FRAMING2x4 STUDS @ 16" O.C.1/2" GYP. BD.CAULK BOTTOM PLATETO CONC. FLOOR2x4 BLOCKINGMIN. 1/2" AIRSPACEAND FOUNDATION WALL2x4 STUDS @ 16" O.C.WOOD CAPBASE TRIMMIN. 1/2" AIRSPACEBETWEEN FRAMING& FOUNDATION WALLSTYLE VARIESAND HEATING PIPE LOCATIONS AND WOOD FRAMING MEMBERS1. THIS ELECTRICAL PLAN MAY VARY DEPENDING UPON PLUMBINGSUCH AS JOISTS, TRUSSES AND STUDS.GENERAL NOTES ELECTRICAL AND/OR GAS HOOK-UP REQUIREMENTS, THIS INCLUDES2. REFER TO SPECIFICATION INFORMATION FOR ALL APPLIANCEBUT IS NOT LIMITED TO WASHER, DRYER, RANGE/COOKTOP,MICROWAVE, OVEN AND/OR ADVANTIUM (WHERE APPLICABLE),DISHWASHER AND REFRIGERATOR.5. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & RECEPTACLESAT THE FOLLOWING HEIGHTS ABOVE FINISH FLOOR:REQUIREMENTS OF ALL GOVERNING CODES.AS REQUIRED BY NATIONAL ELECTRIC CODE (NEC) AND MEETING THE4. PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERUPTERS (GFI)AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.TELEVISION.........14"TELEPHONE........14"OUTLETS.............14"SWITCHES...........42"AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)3. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORSW.H.TANKLESSSCALE:L11LOWER LEVEL FINISH PLAN1/4" = 1'- 0"SCALE:L12LL FINISH ELECTRICAL PLAN1/4" = 1'- 0"SCALE:L13LL FINISHED RECREATION RM. 1/4" = 1'- 0"SCALE:L14FINISHED REC. RM. ELECTRICAL1/4" = 1'- 0"710 FINISHED SF1008 FINISHED SFSCALE:L1AWALKOUT FOUNDATION3/16" = 1'- 0"SOFFIT DETAILNO SCALEHALF WALL: LOOKOUT/EGRESS NO SCALEFOUNDATION FRAME OUT WALLNO SCALEBED/BATH R.I. OPTION SCALE:L15W/ FINISHED REC. ROOM1/4" = 1'- 0" © © UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. X X 160,000 1152 66000 465 465 3102 240 375 375 -90 130 65 20158 Gambrel Path Date Certificate Posted X Passive (No Fan ) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here X R-15 X X X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:66,000 Capacity in Gallons:Other, describe: AFUE or HSPF% 93% Cfm's " round duct OR " metal duct X Not required per mech. code Passive X Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Balanced Ventilation capacity in cfms:Mech Room Capacity continuous ventilation rate in cfms: Total ventilation (intermittent + continuous) rate in cfms: 65 High: Energy Recover Ventilator (ERV) Capacity in cfms:High: Location of duct or system: Below Entire Slab Foundation Wall Perimeter of Slab on Grade Rim Joist (1st Floor) Rim Joist (2nd Floor+) Wall Ceiling, flat Interior R5 + R10 Exterior Interior Interior New Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.1/4/2024 Mailing Address of the Dwelling or Dwelling Unit City Lakeville20158 Gambrel Path Name of Residential Contractor MECHANICAL VENTILATION SYSTEM Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Combustion Air Select a Type Select Type Heat Recover Ventilator (HRV) Capacity in cfms:130 MN License Number Lennar BC001413 THERMAL ENVELOPE RADON CONTROL SYSTEM Type: Check All That Apply Insulation Location Total R-Value of all Types of InsulationNon or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateResidential Load Calculation Heating Loss Heating Gain Cooliing 38,642 18,823 22,736 14 Location of duct or system: Rating or Size Output in Tons:2.5 Efficiency SEER /EER Natural Gas Natural Gas Elect RU160iN ML14XC1S030 Fuel Type Manufacturer Lennox Rinnai Lennox Model ML193UH070XE36B Average U-Factor (excludes skylights and one door ) U: 0.31 Solar Heat Gain Coefficient (SHGC):0.29 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System Duct system air tightness: Heating or Cooling Ducts Outside Conditioned Spaces Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Describe other insulated areas Building envelope air tightness: Windows & Doors 000000Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.”(NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 20158 Gambrel Path US Home LLC dba Lennar Jesse Schwarzrock 612-346-2648 Jesse.Schwarzrock@Lennar.com Residential Development 57174 Chad Johnson Stantec 651-325-6860 chad.johnson@stantec.com University of Minnesota 5/31/23 1/4/2024Kurt NiskaDigitally signed by Kurt Niska Date: 2024.01.04 16:06:16 -06'00' 1/8/24 X PM