Loading...
HomeMy WebLinkAbout18161 Hounds Dr-SurveyDRIVEH O U N D S 5 Drainage and Utility EasementBuilding Setback18161 Hounds Dr 1039. 7 1 1038. 6 8 1037.861037. 1 5 1037. 0 4 1037. 7 9 1038. 2 6 1038. 9 3 1039 . 9 2 1039. 3 2 1038. 9 2 1038.191037.961038.491040.321041.201040. 5 7 10 3 9 . 9 6 U 1037.00 E1042.241040. 6 1 1039. 8 9 1039. 5 4 1038.81 1038. 4 3 U PROPOSED GARAGE PROPOSED FULL BASEMENT IIIII IIII>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >>>>>>>>>>>>IIIIIIIIII>>>>>> > > >>>>>>III10.007.44PROPOSED DRIVEWAY 5.9% SLOPEN00°46'19"W 142.86S89°13'41"W 125.00 N:178063.36 E:519973.14 Curb Stop 30 10 571039.1410 4 0 . 6 6 H P N:178066.83 E:519872.30 Storm Drain Cleanout 104 2 . 8 8 1039.641042.751040.1515.0015.007.44S00°46'19"E8.66S6 0 ° 1 6 ' 1 0 " E 26. 8 9 L=46.30 R=155.00 Δ=17°06'58" L = 1 2 4 . 5 1R=119.91Δ=59°29'51"FROM SW PIPE TO E PIPE R=1037.24 EX SAN MH I=1025.40 (18" PVC) NW I=1025.49 (18" PVC) SE R=1038.38 EX SAN MH I=1025.63 (18" PVC) N I=1025.74 (18" PVC) S I=1028.48 (18" PVC) SE R=1038.38 EX SAN MH I=1025.21 (18" PVC) NW I=1025.23 (18" PVC) SE I=1025.21 (18" PVC) NE T/C=1039.26 EX CB I=1033.50 (18" RCP) N I=1033.64 (18" RCP) S T/C=1037.12 EX CB I=1033.12 (12" RCP) W I=1033.41 (6" PVC) E I=1033.60 (6" PVC) W T/C=1037.15 EX CB I=1033.12 (12" RCP) S I=1033.04 (12" RCP) W I=1033.66 (6" PVC) N T/C=1037.72 EX CB I=1032.61 (18" RCP) SE I=1032.50 (24" RCP) NW I=1032.61 (12" RCP) E I=1033.50 (6" PVC) SE I=1033.73 (6" PVC) NE T/C=1039.19 EX CB I=1032.37 (24" RCP) SE I=1032.14 (24" RCP) NW T/C=1042.12 EX CB I=1031.84 (24" RCP) E I=1031.67 (24" RCP) W I=1033.48 (15" RCP) S R=1037.26 EX CB 1040.271039.33103 9 . 2 9 10 4 1 . 3 0 1041.3 0 1041.101041.301 0 4 1 . 1 3 1 0 4 1 . 3 0 1041.101040.901040.901041.101041.30201 038 .951039.711039.431039.071041.371040 1040 10401040 1042 10402825.4 42 38.00 13.002.00 6.548.00 10.462.00 20.0022.4610.0023.5440.002510 1038. 9 0 1039. 7 6 1039.841039. 5 9 19.546.00 8.00 1 0 4 0 . 0 2 1040.38PORCHEGRESS PIT 25303 L5B6 DATE REVISION SCHEDULE DESCRIPTION BY PROJECT NO. CAD FILE NAME DRAWN BY DESIGNED BY ORIGINAL ISSUE DATE CLIENT PROJECT NO. REVIEWED BY PROJECT SHEET TITLE WITHOUT PRIOR WRITTEN CONSENT. INC. AND MAY NOT BE USED, COPIED OR DUPLICATED THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,FILE LOCATION: S:\PROJECTS\25000 PROJ\25300-25399\25303 STREEFLAND PROPERTY - LENNAR - LAKEVILLE MN\25303 CIVIL-SURVEY\SURVEY PRODUCTION DRAWINGS\LOT CERTS\BLOCK 6\LOT 5\25303 L5B6.DWG 1OF CERTIFICATE OF SURVEY 1 - 21-25303 --/--/-- LAKEVILLE MINNESOTA JW --- --- LENNAR CORPORATION CASLANO LOT 5, BLOCK 6 I HEREBY CERTIFY THAT THIS SURVEY, PLAN, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. DATE LIC. NO.1/5/24 45817 MARK A. SCHWANZ CONSTRUCTION NOTES: 1.Install rock construction entrance. 2.Install silt fence as needed for erosion. 3.Sidewalks shall drain away from house a minimum of 1%. 4.Contractor must verify driveway design. 5.Contractor must verify service elevation prior to construction. 6.Add or remove foundation ledge as required. GENERAL NOTES: 1.Grading plan by ISG last dated May 9, 2022 was used to determine proposed elevations shown hereon. 2.This survey does not purport to show improvements or encroachments, except as shown, as surveyed by ISG or under my direct supervision. 3.Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4.No specific soil investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5.If building footprint exceeds the building pad, additional earthwork and testing will be required to meet the requirements as outlined within the geotechnical report. 6.This certificate does not purport to show easements other than those shown on the recorded plat. 7.Bearings shown are based on the Final Plat. 8.Site address is 18161 Hounds Drive, Lakeville, MN 55044 9.House/Basement type: Lewis EK05 B3 - Left - Full 10.Building dimensions shown are based on Main Floor Plan. 11.Proposed Contours are shown hereon. 12.Topographic survey was completed on January 3, 2024. BENCHMARK: Top nut fire hydrant located in the NE quadrant of Hideaway Trail and Highview Avenue. Elevation = 1038.03 feet AREA TABLE: House/Garage Area = 1,874 sq. ft. Porch Area = 130 sq. ft. Driveway/Walk Area = 1,032 sq. ft. Total Impervious Area = 3,036 sq. ft. Lot Area = 13,382 sq.ft. Impervious Coverage = 22.7% HOUSE ELEVATIONS:Proposed/As-Built Garage Floor = 1041.3 Top of Foundation = 1041.6 Lowest Floor = 1033.6 LEGEND Proposed Building Sanitary Line Water Line Storm Line Curb Stop Manhole/Catch Basin Utility Pedestal Transformer > >> I Set Lath at Property Corner Offset Iron Existing Contour Proposed Contour Proposed Elevation Proposed Spot Elevation Existing Spot Elevation Surface Drainage Direction 982.2 982 982. 5 985.0 5 0 SCALE IN FEET 10 20 Note: Cut and fill quantities include building excavation, driveway, and lot grading. GRADING QUANTITIES (CY) Calc Common Cut -239 Calc Common Fill 420 Driveway*-27 Basement Slab -30 Contracted Amount -71 Additional Amount -0 Sand -7 Swell 20%84 Total Cut -374 Total Fill 504 Total (±)130 1/30/24 Added Storm Drain CLO JMW U Zoning = RS-4 FY - 20' House, 25' Garage SY - 7' Interior, 20' Corner RY - 30' SY Buffer - 30' RY Buffer - 50' The curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection. EROSION CONTROLMUST BE INSTALLEDBEFORE EXCAVATION *Maintain 6" between bottom of siding and sod.*No structures in easements. *Draintile connection required. ENGINEERING REVIEWED Date:__________________01/30/2024 asobottka