Loading...
HomeMy WebLinkAbout20429 Galveston Pl-SurveySTOSTOSTOSTOSTOSTOSTOSTOSTOSTOSTOSTOSTODrainage and Utility Easement per theplat of CEDAR HILLS 3RD ADDITIONProposed HouseBristol, EN12, Elev. A3LookoutLowest Floor Elev. = (1011.23)Top of Foundation @ LookoutElev.= (1014.40)Sid e w a l k 6WATWATWATWAT600+00.00 STOSTOSTOSTOSTOSANSANSANSAN SANSANSANSANSANSANSANBuilding Pad per Grading PlanBuildingSetback51010 510 1 0 55LOT 109GALVESTONPLACEL=60.16R=213.40Δ=16°09'14"N39°45'06"E 226.23 N2 3 ° 3 5 ' 5 2 " E 1 6 2 . 5 9S89°52'47"W 128.807.06S14°50'21"E1007.8(1008.1)1005.8(1005.4)1017.5(1017.6)1015.1(1015.6)GaragePorchMorning Room1011.911016.991018.881012.27X 1014.89TCX 1016.27TCX 1016.96TC35. 0 1 12.9080.0610.00 17.7530. 7 5 14.8718. 7 9 20.002.0 010.0021.506.1226.044.2510.0016.7539.0731.5722.7527.7537.4 9 60.14 64.9 6 128.60 60.14 37 . 4 9 20.00SST(1018.90)X (1016.4)X (1018.4)1016.6 X 1016.3 X X 1013.6 1013.7 X(1013.7) XCSTExisting SidewalkX 1005.48RECOCO(5. 4 % )(1013.7) X(1013.2) X(1 0 13 .2 ) X1012101010081006101810161014 1012101410186.130.1360 foot PublicRight of Way166219.93 N527696.34 E166220.43 N527670.56 E166073.69 N527508.28 E166078.97 N527499.39 EDrain Tile CleanoutProperty cornernot set falls onCatch BasinX (1006.6)EOF1006 102015.0014.401016 N:\0025850.01\DWG\SURVEY\3RD ADD\0025850.01B09L10 3RD.DWG Lakeville, MinnesotaCedar HillsCertificate of Survey.MJWGMKLennarPREPARED FOR:Phone   :hLWeZaWer 'rLYe 6XLWe Fax  0LnneWonNa 01 Toll Free  .FIELD CREW:DRAWN:CHECKED:DESIGNED:© 2024 Westwood Professional Services, Inc.Common Ground AllianceCall 48 Hours before digging:811 or call811.comPROJECT NUMBER: 0025850.010'30'60'LEGENDCABLE TV BOXTVNATURAL GAS METERGSTREET LIGHTELECTRIC BOXEELECTRIC METERESANITARY MANHOLESSEWER CLEANOUTCOCATCH BASINSTORM MANHOLESTTELEPHONE BOXTGATE VALVEHYDRANTWATER METERWCURB STOP BOXCSWATERMAINSANITARY SEWERSTORM SEWERSANSTOWATFLARED END SECTION1) Curb & gutter and utilities are existing.2) Building dimensions do not reflect brick facing.3) Grading Plan by Westwood Professional Services Inc.initial submittal date 02/06/20.4) Building shown reflects Bristol foundation plan, sheet A2, dated 12/01/23.Lot 10, Block 9, CEDAR HILLS 3RD ADDITION,according to the recorded plat thereof,Dakota County, Minnesota.Address- 20429 Galveston PlaceGarage Floor Elev. = (1018.90)(at overhead door)Top of Poured Foundation Wall Elev. = (1019.23)Lowest Floor Elev. = (1011.23)Top of Foundation @ Lookout Elev. = (1014.40)I hereby certify that this survey was prepared by me or undermy direct supervision and that I am a duly Licensed LandSurveyor under the laws of the State of Minnesota. 01/25/2024Mathew J. Welinski DateMinnesota License No. 53596matt.welinski@westwoodps.comDenotes iron monument foundDenotes iron monument setx xxx.x Denotes existing elevationx (xxx.xx) Denotes proposed elevationBenchmark- Minnesota Department ofTransportation Control Point "1914H", Elevation = 959.11 (N.A.V.D. 1988),not graphically shown.IMPERVIOUS SURFACE CALCULATIONSLot area = 17,014 sq. ft.House area = 1,932 sq. ft.Porch area = 92 sq. ft.Driveway and Sidewalk = 1,024 sq. ft.Impervious area 3,048 sq. ft. /17.9 % of total of lot areaNW Quarter, Section 27, Township 114, Ra The curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.EROSION CONTROLMUST BE INSTALLEDBEFORE EXCAVATION*Maintain 6" between bottom of siding and sod.*No structures in easements.*Draintile connection required.ENGINEERING REVIEWEDDate:__________________01/25/2024asobottkaZoning = RST-2FY - 20' House, 25' GarageSY - 7' Interior, 20' CornerRY - 30'SY Buffer - 30'RY Buffer - 50'The curb box, drain tile cleanout, and catchbasin(if applicable) must be inspected andaccepted before As-Built escrow monies willbe released. All structures must be flushwith the sod. This will be scheduled with thelandscape inspection.EROSION CONTROLMUST BE INSTALLEDBEFORE EXCAVATION*Maintain 6" between bottom of siding and sod.*No structures in easements.*Draintile connection required.ENGINEERING REVIEWEDDate:__________________01/25/2024asobottkaZoning = RST-2FY - 20' House, 25' GarageSY - 7' Interior, 20' CornerRY - 30'SY Buffer - 30'RY Buffer - 50'