Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA221769 - 4660 172nd St W-Permit Pack
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C6:126:128:128:124:126:126:12AAAABBBBCCCC6:128:128:123'-0" 5'-0"8:1220' RIDGE VENT8' RIDGE VENT 12' RIDGE VENT ROOF PLAN1/8"=1'-0"AT FRONT ONLY1/2"=1'-0"TYPICAL WDW & DOOR TRIM3 1/2" TRIM5" TRIM5" TRIMHARDBOARD TRIMHARD BOARD SIDINGHARD BOARD SIDING2-SIDED OUTSIDE CORNERSHEATHINGHDBD TRIM1-SIDED OUTSIDE CORNERHARD BOARD SIDINGVINYL SIDING"J" CHANNELHARDBOARD TRIM3 1/2" TRIM 1.0X20860 KENBRIDGE COURT, SUITE 100LAKEVILLE, MN 55044 (952)985-72725490-B-3.1GRANTDRAWN: 10-5-2015-AWPC#842: 1-1-2021-LLSPEC HOME CUST:128126XXXXXADDRESS NUMBERSTEEL PANEL OVERHEAD DOOR4:12 PITCH6:12 PITCHDDFFFNORTHERN CRAFTSMAN1286:12 PITCH8:12 PITCHD1x6-1/4" FROM TOP OF THRESHOLDTO TOP OF JOISTELEVATION B568 TOTAL COVERAGE8" TRIMFRAIN DIVERTER 222 SF STONE COVERAGE (28.6%)EREFAVINYL LAP SIDINGPRODUCTCBD5/4X6 CEMENT BD. TRIMREFMATERIAL LEGENDECEMENT BD. SIDINGPRODUCTGFHCEMENT BD. SHAKES5/4X8 CEMENT BD TRIMNOT USEDNOT USEDC.B. BOARD-N-BATTENHHPC#854: 1-15-2021-LLREVISED: 1-18-2021-CFWOODGRAIN PANEL5/4" x 5" - WOODGRAIN5/4" x 10" - WOODGRAINWOODGRAIN PANEL4/4" x 3" - WOODGRAIN(FRONT & REAR)6x6 POSTBLOCKING2x4 TREATED1/2" OSB4/4" x 3" - WOODGRAINCORNER TRIM(FRONT & REAR)4/4" x 2" - WOODGRAINCORNER TRIM1/2" OSBOVER 2xTREATED FRAMEBEAM1/2" OSBOVER 2xTREATED FRAMEWOODGRAINPANELWOODGRAIN5/4" x 10"FLASHINGSTONE CAPSTONE CAPTAPERED COLUMN WITHSTONE PIER1/4"=1'-0"1/4"=1'-0"2"=1'-0"2"=1'-0"(SIDES)16" AT BASE16" AT BASE30°REAR ELEVATION1/8"=1'-0"RIGHT ELEVATION1/8"=1'-0"LEFT ELEVATION1/8"=1'-0"42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BEMAINTAIN 6" MIN SEPARATION WOOD to EARTH1'-4"7 7/16" HEEL2'-0"1'-0"8:12 PITCH124F8:12 PITCH1267 7/16" HEELA 1267 7/16"HEEL1'-4"8:12 PITCH6:12 PITCHAA1x CEDAR6:12 PITCH1'-0"42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BE1'-4"1'-4"6:12 PITCHASPHALT SHINGLES10 1/8"HEEL 128FLASH OVER ALL EXT OPGS12840% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806.2FGRADE:930.57GRADE:930.57GRADE:930.57GRADE:930.57GRADE:935.37GRADE:934.7GRADE:934.7GRADE:935.371-1/2"1"2-3/4" .96"3-1/2"3-1/2"10 1/8" HEEL 7 7/16"HEEL1'-4"1'-4"6 1/4"1'-4"2'-0"3'-2" 11 1/4" AT TOP 11 1/4" AT TOP1'-4"11 1/4"3'-5"PERMIT/CONSTRUCT PLANS4660 172ND STREET WEST LOT 6 BLOCK 10 - BROOKSHIRE PERMIT/CONSTRUCT:2-9-24-AFGRADE:934.7GRADE:935.37Secure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode02/14/2024jnuetzman These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C3.0XGRANT 5490-B-3.1DEL LL LINEN CLOS:7-6-23-LLPERMIT/CONSTRUCT:2-9-24-AFWINDOW & DOOR SCHEDULE-LOOKOUTCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#5036 SLIDER0.2960" X 42"BEDROOM0.3215036 SLIDER0.2960" X 42"FAMILY RM.0.322POURED CONC. WALL8" THICK, 8'-4" HIGH5036 SLIDER5036 SLIDER5036 SLIDER2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C. POURED CONC. WALLTREATED BOTTOM PLATE18x8 CONC. FTG.8" THICK, 3'-6" HIGHCOCKSILLBASEMENT PLAN1/4"=1'-0"UNEXCAVATED16'-3" M.O.6" CURB (OMIT CURB AT GARAGE DOOR OPENINGS)6" THICK16"x8" FTG.POURED CONC. WALLMIN. 3'-6" BELOW GRADE8'-3" M.O.2 ANCHOR STRAPS WITHMIN. UPLIFT CAPACITY OF 4,200 LBS.6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADE6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 8'-4" HIGHSILLCOCK6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADEA/C2 ANCHOR STRAPS WITHMIN. UPLIFT CAPACITY OF 4,200 LBS.UP16R3/4B62 SQ. FT.2-82-4DROPPED BEAMUNFINISHEDSTORAGE16"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGH16"x8" CONC. FTG.BEDRM211 SQ. FT.2-65-016"x8" CONC. FTG.POURED CONC. WALL8" THICK, 8'-4" HIGHFAMILY RM698 SQ. FT.2x6 BRNG WALL30x30x12CONC. PAD FTG.30x30x12CONC. PAD FTG.UNFINISHEDMECH.2-618" MFD FLOOR TRUSSES INSTALL PER MFRS SPECS 2x6 BEARING WALL2x6 STUDS AT 16" O.C.6" HALF HIGH CONC. CURB14x8 CONC. FTG.SUMPACWHF.D.NOTE:MECHANICAL EQUIPMENT LAYOUT WILL VARYPER PLUMBING, ELECTRICAL, MECHANICAL,STRUCTURAL AND/OR SITE CONDITIONSHV12" FTG VOIDFOR PLUMBINGRADONVENT PIPE34x48FBGL SHWRNOTE: ROCK WHOLELOWER LEVEL CEILINGEXCEPT FOR 80 SQ FTAT MECHANICAL ROOM2-84'-0"FBSMAX.BRACINGFOUNDATIONSYSTEMBRACINGFOUNDATIONSYSTEMFULL/LO BSMTBRACING ATFOUND.FBSFULL/LO BSMTBRACING ATFOUND.CPT.12" FTG VOIDFOR PLUMBINGTPH 24" TOWEL BAR36"CPT.HD-FLR10X48 FOOTINGSFILL14"x8" CONC. FTG.POURED CONC. WALL6" THICKMIN. 3'-6" BELOW GRADEPOURED CONC. WALL16"x8" CONC. FTG.6" CURB, 2" LEDGE7'-0"47'-0"21'-6"9'-0"9'-6"14'-0"33'-0"50'-0" 31'-0" 18'-0"13'-0" 50'-0"18'-0"8'-0"22'-0"26'-0"29'-6"18'-0"5'-0"29'-0"1'-7 1/2"16'-3"1'-7 1/2"8'-3"1'-1 1/2"3'-0"7 1/2"2'-0"47'-0"18'-0"8'-0"9'-6"19'-6"15'-6"2'-6"11'-0"9'-7 1/2"7'-2 1/2"9'-1 3/4"11'-1 3/4"12'-0" 3'-6"2'-6"6'-1 1/2"4'-2 1/8"3'-3 5/8" 3 1/2" 7'-9 1/4" 6'-0"3'-0"16'-6"3'-0"19'-0"17'-6"18'-0"8'-0"5'-6"12'-0"1'-0" 11'-0"930.57934.7 935.3793 0 . 5 78" STEP IN TOPOF FOUNDATION8" STEP IN TOPOF FOUNDATIONDROPPED 8"PERMIT/CONSTRUCT PLANS4660 172ND STREET WEST LOT 6 BLOCK 10 - BROOKSHIRE PLAN OPTIONSLOOKOUT BASEMENT FINISHED LL BASEMENT CONCRETE FRONT PORCH UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. WALL SECTION 2F1 RETAINING WALL TYPESTAIRWAY FOUNDATION WALL(3) #4 LONGITUDINAL BARSAT TOP OF FOOTING#4 HORIZ. BARS@ 24" O.C.8" MIN. C.I.P.CONCRETE WALLVERTICAL BAR OPTIONS:#5 BARS @ 24" O.C.OR #6 BARS @ 36" O.C.#4 BARS @ END &BEND OF HOOK5'-0" HOOK OPTIONS:#5 HOOKS @ 12" O.C. OR#6 HOOKS @ 18" O.C.TRANSVERSE BARS OPTIONS:#5 BARS @ 24" O.C. OR#6 BARS @ 36" O.C.10" THICK C.I.P.CONCRETE FOOTING1'-6"3'-6"2" TO VERTICAL BARS & HOOKS1'-6"4'-0"2"3"8'-4" MAX.SLAB-ON-GRADE WOOD WALL12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 48" O.C. MAX. OR EQUIV.FRAME WALL ABOVESLAB-ON-GRADE &INSULATION BY OTHERS6" MIN. C.I.P. CONCRETESTEM WALL(2)9-1/2 Versa Lam(2)9-1/2 Versa Lam(2)9-1/2 Versa Lam(2)7-1/4 Versa Lam GARAGE1ST FLOOR PLAN1/4"=1'-0"DINETTE1/2BMUDROOMThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C4.0X3040 SHSUBFLOOR TO43 1/2" FROM TOP OFSET KITCHEN WINDOWSRGH.OPG. OF WINDOWDROPPED HDRFLUSH HDRSLOPE TO DOORS4" CONC FLOORON ALL WALLS & CEILINGGYP. BOARDNOTE: 686 SQ. FT.16x7 OVERHEAD DOOR8x7 OVERHEAD DOOR3-02x6 BRNG WALL2-8PED.HD-FLRHD-FLRHD-FLRFOYERHD-FLR22x30 ATTIC ACCESS 1312 SQ. FT.NOTE:9'-1 1/8" PLATE HEIGHT TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)TYP. FIRST FLOOR WINDOW HEAD HEIGHT AT 7'-11 3/8" U.N.O.BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFRUP16RDN16R5-02-4TPH 24" TOWEL BARGRANT 5490-B-3.1DEL LL LINEN CLOS:7-6-23-LLPERMIT/CONSTRUCT:2-9-24-AFNOTE: FINISHSTAIRWAY DOWN TOBOTTOM STEP6068 SGDSET HEAD HEIGHT AT 6'-11 3/8"WINDOW & DOOR SCHEDULECALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#2W 3050 SHFLEX ROOM13W 3050 SHGREAT ROOM13040 SHKITCHEN10.310.3172 1/8" X 60 1/4"0.31108" X 60 1/4"0.310.3136 1/4" X 48"0.31GREATROOMBEDRM #53W 3050 SH2x4 BRNG WALLCPT.CPT.14" MFD I-JOISTS INSTALL PER MFRS SPECS 5-0TUB/SHWR8'-10"X12'-2"CPT.HD-FLR3040 SHPOCKETOFFICE0.3172 1/8" X 80"0.326068 SGDDINETTE12-04-02-6RADONVENT PIPETPH24" TOWEL BARBATH#3HD-FLR2-436"HEADER2x6 WALLCORNER GAS FPRGH OPG:42"x40 1/8"3-0 DOOR0.31FOYER0.23138 1/4" X 83 1/4"(MATCH GREATRM FLOORING)37" WIDE FRAMED DOWNSOFFIT (PART OF CORNERFIREPLACE OPTION)3040 SHOFFICE10.3136 1/4" X 48"0.31SHEETROCKEDOPENINGMFD TRUSSES AT 24" O.C.47'-0"50'-0" 31'-0"19'-0" 50'-0"13'-7 1/4"6'-0"24'-0"26'-0"17'-6"19'-6"5'-0"9'-6"10'-10"6'-0"29'-0"47'-0"12'-5 1/2"6'-0 1/2"9'-9"9'-9"4'-9"4'-2"2'-8"9'-8 1/2"9'-8 1/2"2'-0"3'-6"2'-8"4'-2 1/8"3'-3 5/8" 7'-9 1/4" 3 1/2" 6'-4 3/4"5'-3"10'-0"2'-0" 22'-0"2'-0" 17'-9 1/4"13'-2 3/4"7'-8 1/4"10'-5"8'-9 1/4"9'-0"15'-11 1/4"3'-6"3'-3 1/8"3'-0" 2'-10" 3'-6"5'-10" 3'-10 3/4"4'-11 1/2"6'-9"6'-1"6'-4"4'-5 3/4"4'-6"6'-3 3/4"3'-0 5/8"40'-8 1/4"14'-6"11'-0"WOOD RAILINGWOOD RAILING2W 3050 SHCONC. PORCHTYPICAL PORCH COLUMN:16" WIDE DROPPED SOFFIT(SEE SECTION)140 SQ. FT.6x6 TREATED POST WITHIN16" TAPERED TO 12" BOXED COLUMNOVER 16" (FRAMED) SQUARE STONE BASECOVEREDDROPPED BEAMDROPPED BEAMDROP HEADER HGT AT PORCHNOTE:8" FROM HOUSE PLATES6"18'-0"12'-10"5'-2"5'-8"7'-2"8'-0"3'-6"2'-0"10'-0"8"8"7'-4"6'-10"5'-6"3'-0"2'-5"2'-9"KIT.REF.SINKDWHD-FLR20 AMP.MICRO HOODCIRCUITCOOKTOPOVENS2-010" OVERHANG 24"x72"BASEDROPPED HDRVENT HOOD TO OUTSIDE 8'-0"2'-3" 2'-3"2'-3"4'-8"8'-6 1/2"3'-7 1/4"DROPPED 8"PERMIT/CONSTRUCT PLANS4660 172ND STREET WEST LOT 6 BLOCK 10 - BROOKSHIRE TILE BACKSPLASH1/2 OFFSETTILE BACKSPLASH1/2 OFFSETTILE BACKSPLASH 1/2 OFFSET TILE BACKSPLASH1/2 OFFSETIRRIGATIONSYSTEMPLAN OPTIONSGAS FIREPLACE KITCHEN TILE BACKSPLASH - 1/2 OFFSETSIGNATURE KITCHEN W/GAS COOKTOPWASTE BASKETIRRIGATION SYSTEMSTAIR RAILINGCONCRETE FRONT PORCH -Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).55PFHPFH55662.53.5(2)7-1/4 Versa Lam(2)7-1/4 Versa Lam(2)9-1/2 Versa Lam(2)7-1/4 Versa Lam(2)7-1/4 Versa Lam(2)7-1/4 Versa Lam(2)9-1/2 Versa Lam(2)11-7/8 Versa Lam(2)11-7/8 Versa Lam(2)14" Versa Lam 1241 SQ. FT.2ND FLOOR PLAN1/4"=1'-0"LIVING AREAThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C5.0XGRANT 5490-B-3.1DEL LL LINEN CLOS:7-6-23-LLPERMIT/CONSTRUCT:2-9-24-AFNOTE:8'-1 1/8" PLATE HEIGHT TYPICALWDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)TYP. SECOND FLOOR WINDOW HEAD HEIGHT AT 6'-11 3/8" U.N.O.BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFRCENTER OF SHWR HEAD OPG 84" ABOVE SUBFLOOR BATH #1 W/1/2"=1'-0"SHOWER BASEFIBERGLASS BASE18"DETAIL 'A'36X60 FIBERGLASSCL16" @ 34" SHWR4'-0"CLSHOWERCONTROLTO CENTER OF SHOWER VALVE SEATS 10-3/4"36"VALVE17-3/16" @ 36" SHWRBEDRM #1BEDRM #2LOFTCPT.CPT.CPT.3050 SH2W 3050 SH3020 FXTPHGIRDER TRUSSMFD TRUSSES AT 24" O.C.DN16R2x6 WALLWDCABTS.LAU.HD-FLR2-85-0TUB/SHWR2x6 WALLBEDRM #3CPT.24" TOWEL BAR BATH#2HD-FLR2-466"BATH #1HD-FLRW.I.C.2-6CPT.5-05-01-62-62-63050 SH42" HIGH HALF WALLW/ WOOD CAP42" HIGH HALF WALLW/ WOOD CAP3020 FXRADONVENT PIPE2x6 WALLA.P.22x30ATTICACCESSMFD TRUSSES AT 24" O.C.72"3050 SH3050 SHTPH 2-42-42-42040 SHTEMP. GL.42x60 FBGL TUBPROVIDE ACCESS24" TOWEL BAR 6" SPLASH2040 SHTEMP. GL.42" HIGH HALF WALL W/ WOOD CAP WINDOW & DOOR SCHEDULE- UPPER LEVELCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#BEDROOM #123050 SH3050 SHBEDRM #213050 SHBEDRM #312W 3050 SHBEDRM #412040 SHBATH #12BEDRM #313020 FXSTAIRWAY13020 FX0.310.3172 1/8" X 60 1/4"0.3136 1/4" X 60 1/4"0.310.3136 1/4" X 60 1/4"0.310.3136 1/4" X 60 1/4"0.310.3124" X 48"0.3136 1/4" X 24"0.310.336 1/4" X 24"0.310.3NOTES:ALL TOE LEDGES AND SEATSARE 18" OFF THE SUBFLOORBATOE LEDGES ARE MODEL BT-17BY BETTER BENCH SYSTEMSHEIGHT OF SHOWER SHELVES TO BEDEPENDENT ON TILE SELECTIONSMIXER VALVE IS ALWAYSCENTERED BELOW SHOWER HEADCDTHIS DETAIL REFLECTS MODEL #'s,HEIGHTS & LOCATIONS ONLY, ANDDOES REFLECT QUANTITIES PURCHASEDREFER TO DEC SELECTIONS FORSTD & OPTIONAL INCLUDED FEATURES135°135°47'-0"5'-0"31'-0" 12'-10"6'-6"11'-8" 31'-0"5'-0"26'-0"18'-0"29'-0"47'-0"9'-6"7'-6"12'-0"14'-3"3'-7 7/8"3'-10 7/8"5'-4"5'-8"9'-0"9'-0"5'-2"4'-4"11'-9"2'-6"11'-9" 3'-11 3/4"7'-9 1/4"11'-0"2'-6"11'-6"2'-9"1'-11 1/2"3'-6"8'-6"9'-6"2'-3"5'-7"6'-5"10'-11 1/4"10'-0"9'-4"17'-6 3/4"10'-0"7'-5 1/4"3'-6"8 3/4"16'-6 1/4"11'-8"5'-1" 8'-0"6'-3"3'-0"7'-11 1/4"2'-3" 4'-3 7/8"3'-5 3/8"W/ 36" GLASS PANEL2x4 WALL, 48" HIGHW/ CT SURROUND34x60 FBGL BASESHWRSHELVES3'-9"PERMIT/CONSTRUCT PLANS4660 172ND STREET WEST LOT 6 BLOCK 10 - BROOKSHIRE PLAN OPTIONSBATH #1 TILED SHOWER WALLSLAUNDRY ROOM CABINETS -Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).HIP GIRDER HIP GIRDER These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C6.0X1/4"=1'-0"ELECTRICAL PLANFINISHED BASEMENTS SDSD/CMDSFANLACWHF.D.A/CHVRADONVENT PIPE15 AMP CIRCUITFOR POWER VENTW/ SINGLE RECEPTACLEGFIWPSSUNEXCAVATEDUNFINISHEDSTORAGEBEDRMUNFINISHEDMECH.SSSS SCGFI 3/4BS FAMILY RMLLLLLLLLLLOW VOLTAGESYSTEM RECEPTACLEWATER SOFTRECEPTACLEGRANT 5490-B-3.1DEL LL LINEN CLOS:7-6-23-LLPERMIT/CONSTRUCT:2-9-24-AFSUMPSEPERATE 15 AMP CIRCUITW/ SINGLE RECEPTACLEFILLDROPPED 8"PERMIT/CONSTRUCT PLANS4660 172ND STREET WEST LOT 6 BLOCK 10 - BROOKSHIRE PLAN OPTIONSLOOKOUT BASEMENT FINISHED LL BASEMENT CONCRETE FRONT PORCH GARAGEELECTRICAL PLAN1/4"=1'-0"1/2BMUDROOMThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C7.0XSPRINKLERSYSTEMRECEPTACLESGFISSSSSSFANGFIWPTCHIMESSS1ST FLOORSWPELECTRICAL PLAN1/4"=1'-0"RADONVENT PIPE2ND FLOORCEILING FANSS GFIGFISSSSS GFIFANSD/CMDSD/CMDSDSDSDLBEDRM#1BEDRM #2LOFTBEDRM #3BATH#2BATH #1W.I.C.SSFANCS ROUGH-INLFANSHCPGFISS2nd SMARTHOME RECEPTLLLLLLLLLLLLLLLFOYERLBEDRM #5RADONVENT PIPESSSDCLBATH#3OFFICESPART OF OPTCORNER FIREPLACESGFIFANSSLSSLUSBDROUGH-INBLANK PLATELSGREATROOMLLLLLLLLSSS DINETTELLSD/CMDGRANT 5490-B-3.1DEL LL LINEN CLOS:7-6-23-LLPERMIT/CONSTRUCT:2-9-24-AFPEND.PEND.S LSSTECHTUBE3'-0"9'-6"7'-1 5/8"SSDISP.SSSS LLLLLKIT.USBLVENT HOODTO OUTSIDEAPPLIANCES TO BEON A GFCI OUTLETNOTE: ALL KITCHENRGH-IN INSIDECABINET ONLYLCONC. PORCHCOVEREDCD CDDROPPED 8"PERMIT/CONSTRUCT PLANS4660 172ND STREET WEST LOT 6 BLOCK 10 - BROOKSHIRE PLAN OPTIONSGAS FIREPLACE KITCHEN TILE BACKSPLASH - 1/2 OFFSETSIGNATURE KITCHEN W/GAS COOKTOPWASTE BASKETIRRIGATION SYSTEMSTAIR RAILINGPLAN OPTIONSBATH #1 TILED SHOWER WALLSLAUNDRY ROOM CABINETS CONCRETE FRONT PORCH IRRIGATIONSYSTEM These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C9.0XGRANT 5490-B-3.1DEL LL LINEN CLOS:7-6-23-LLPERMIT/CONSTRUCT:2-9-24-AFCROSS SECTION B-B1/4"=1'-0"MFD TRUSS126GIRDER TRUSSBEDRM #5GREATROOMFUTUREFAMILY RMUNFINISHEDSTORAGELOFTBATH #1DROP HEADER HGT AT PORCHNOTE:8" FROM HOUSE PLATES18" MFD FLOOR TRUSSES3/4" 250 SUBFLOOR14" MFD I-JOISTS3/4" 350 SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOORCROSS SECTION A-A1/4"=1'-0"8'-4" POUREDCONC WALL3 1/2" CONC. FLOORMFD TRUSS126DINETTE4" CONC. FLOORGARAGE18" MFD FLOOR TRUSSES3/4" SUBFLOOR14" MFD I-JOISTS3/4" SUBFLOOR2x10 JOISTS2x10 JOISTSBEDRM16" MAX SPAN FORVINYL SOFFIT PANELS.FRAMERS TO ADD NAILINGSTRIPS AS NEEDED. R703.3.1.29'-1 1/8" 10'-3 7/8"9'-8 1/4" 8'-1 1/2"8'-1 1/8"1'-4"7 7/16"5'-0"26'-0"31'-0"8" 9'-1 1/8" 10'-3 7/8"9'-8 3/4" 8'-2"8'-1 1/8"1'-4"7 7/16"1'-4"7 7/16"COVEREDCONC. PORCHCONC. STOOP16" WIDEDROPPED SOFFITVERIFY DEPTHPER BEAM SIZEDROPPED BEAM124OPTIONALCONC. PORCH8'-0"5 1/2"1'-4"2'-0"7'-4"7 7/16"HEEL8"8"DROPPED 8"PERMIT/CONSTRUCT PLANS4660 172ND STREET WEST LOT 6 BLOCK 10 - BROOKSHIRE These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2014C10.0XGRANT 5490-B-3.1DEL LL LINEN CLOS:7-6-23-LLPERMIT/CONSTRUCT:2-9-24-AFCROSS SECTION C-C1/4"=1'-0"HAND RAIL ALL STAIRSPROVIDE MIN. 6'-8" HEADROOM3) LSL STRINGERS7 3/4" MAX RISE10" TREAD CUTSTAIR DATAMIN HEADROOM LOFTLAU.BEDROOM #5UNFINISHEDMECH.MUDROOM1/2BUNFINISHEDSTORAGEBEDRM #3MFD TRUSS812MFD TRUSS81218" MFD FLOOR TRUSSES3/4" 250 SUBFLOOR14" MFD I-JOISTS3/4" 350 SUBFLOOR8'-4" POUREDCONC WALL3 1/2" CONC. FLOORTHE SLOPING OF THE FLOORBE PROTECTED WHEREVER4" CONC. GARAGE FLOORRIGID INSULATION MUSTCREATES AN EXPOSURE.GARAGE SLAB LEDGE DETAIL5/8" GYP. BD.1/2" SHEATHINGMIN. R-20 INSULATION2x6 STUDS AT 16" O.C.HOUSE WRAPSIDING PER ELEV.BARRIER PASTACOUSTICAL SEALANTEXTEND POLY VAPOR1-1/2" THERMAX2-1/4"X12" DUCTINSULATION(R-10 x 2)1/2"=1'-0"WALL DETAIL1/2"=1'-0"MIN HEADROOM TYPICAL WALL SECTION1/2"=1'-0"9'-1 1/8"TRUSSES PER PLAN3/4" SUBFLOORVARIESSEE PLANVARIES122x6 STUDS AT 16" O.C.BLOCK AT MIDPOINT2x6 BEARING WALL14x8 CONC. FTG.6" HALF HIGH CONC. CURB. BLK.1/2" ANCHOR BOLTSOMIT BEARING WALLAT STEEL OR LVL BEAMR-49 INSUL.MFD TRUSSESA I R C H U T E S APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGSNOTEDUNLESSOTHERWISENOTEDUNLESSOTHERWISEOVER 1/2" SHEATHINGSHINGLES OVER FELT PAPERRIGID WIND WASH INSTALLED EXTENDINGBARRIER MUST BETO WITHIN 1-1/2" to 2"FROM BOTTOM OFROOF SHEATHING4 MIL. POLY VAPOR / AIR BARRIERALUMINUMCORNICEVENTS40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806EXT. SPRAY-ON WATERPROOFINGTREATED SILL PLATEAPPROVED ANCHORPER CODE (IRC R403.1.6)16x8 CONC. FTG.RUN INTO SUMP BASKETCONTINUOUS DRAIN TILEWHERE APPLICABLETREATEDSILL PLATEVERTICAL REINFORCINGAS SOIL COND. REQUIREW/ SILL SEALERMIN. 42" BELOW FINISHED GRADEALL EXTERIOR FOOTINGS TO BE4" INCH CLEAN AGGREGATE ORCONCRETE SLAB AND PREPARED SUBGRADE6 MIL POLY V.B. W/ LAPPED SEAMS 12" BETWEENAPPROVED GAS-PERMEABLE LAYERPASSIVE SUB-SLAB DEPRESSURIZATIONSYSTEM REQUIRED PER MINNESOTARESIDENTIAL ENERGY CODE 1322.2100POURED CONC. WALL8" THICK, 8'-4" HIGH2x6 LOOKOUT WALL2x6 STUDS AT 16" O.C.ANCHOR BOLTS AT 6' O.C.8" THICK, 42" HIGHPOURED CONC. WALL16x8 CONC. FTG.TREATED BOTTOM PLATE2x6 WALKOUT WALL2x6 STUDS AT 16" O.C.ANCHOR BOLTS AT 6' O.C.POURED CONC. WALL(6" CURB, 2" INT. LEDGE)16x8 CONC. FTG.TREATED BOTTOM PLATE8" THICK, 42" HIGHOPENINGS, JOINTS AND SUMPSFOUNDATION WALL & SLABSEAL JOINT BETWEEN3-1/2" CONC. FLOOR SEALED AT8'-1 1/8"1/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.JOISTS PER PLAN3/4" SUBFLOORSEE PLANVERTICAL CLEARANCE OF NOT LESS THANTHE EXTERIOR WALL TOP PLATETO THE ROOF SHEATHINGSIX INCHES FROM THE OUTSIDE EDGE OF6" MIN. HEEL 6'-0" OF ICE & WATER SHIELDINSTALL PER MFR'S SPECSTERMINATE 12" ABOVE ROOF2x6 SUBFASCIASEALANT BY CARPENTERPRIOR TO SHEATHINGPROVIDE RECEPTACLE FOR FUTURE RADON FANVENT PIPE SHALL BE INSTALLED WITH A MINIMUM24" HORIZONTAL CLEARANCE AND 36" VERTICALCLEARANCE TO ALLOW FOR FUTURE INSTALLATIONOF RADON FAN (ACTIVE SYSTEM)W/ VAPOR BARR.5/8" GYP. BD.APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGS4 MIL. POLY VAPOR / AIR BARRIERW/ APPROVED SEALANTGYP. BD. W/ VAPOR BARR.1/2" SAG-RESISTANT1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"TO EACH SIDE OF "T" FITTING IN AGGREGATE10' SECTION OF PERFORATED PIPE CONNECTED1/2" OSB or 1/2" TREATED PLYWDAT GROUND LEVEL APPLICANTIONSTO MAINTAIN PERMANENT CONTACTWITH THE UNDERSIDE OFTHE SUBFLOOR DECKINGFLASHING OVER XPINSULATION. XP TO RUNMIN. 6" BELOW GRADEFINISHED GRADEWILL VARYJOIST CANTILEVER DETAIL(R-30.5) (STC - 41)5" MIN. POLYURETHANE FOAM2x6 EXTERIOR WALLR-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.171/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.R-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.172x6 EXTERIOR WALL3.5" MIN. POLYURETHANE FOAMAT PERIMETER R=203.5" MIN. POLYURETHANE FOAMAT PERIMETER R=20GYP. BD. EXCEPT 80 SF AT1/2" SAG-RESISTANTRUNNING THRU UNCONDITIONEDSPACES TO HAVER-4 INSUL. (MIN)VENT PIPER-10 RIGID INSULATIONINTENDED FOR EXTERIOR USEASTM C578, C612 or C1029INSTALLED PER MFR'S SPECSALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTERALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTER5000 PSI TESTED -OR-APPROVED ADMIXTURETHE MECHANICAL ROOMOF FOUNDATION WALL16x8 CONC. FTG.5000 PSI TESTED -OR-APPROVED ADMIXTURE(IF REQUIRED PER FOUNDATIONEXTEND OVER SILL PLATER-5 RIGID INSULATION(AT RIGHT AND LEFT SIDEOF HOME ONLY)SEALED AND TAPED AT TOPCALCULATIONS, R402.2.8.A)R-5 RIGID INSULATION(AT SIDE LOOKOUT FOUNDATION ONLY,NOT AT REAR LOOKOUT WALLS)R-5 RIGID INSULATION-ON INSIDETAPE & SEAL AT TOPFLASHING OVER XPINSULATION. XP TO RUNMIN. 6" BELOW GRADEDRAINTILE AT WALKOUT WALLS(HILLCREST ONLY)W/ R-10 DRAINAGE BOARDROLL-ON WATERPROOFINGWALL EDGE, ACROSS THE TOP, ANDEXTEND FROM TOP INTERIOR6" DOWN THE EXTERIOR WALL FACE(SEE HANSON ENGINEERING)2x10 JOISTS2x10 JOISTSLIGHT FIXTURES1/2"=1'-0"BLOCKING AT4" DIA. HOLE14" TO TOP OF STONE VENEER 1"=1'-0"WALL DETAILLOOKOUT FINISH2x6 TREATEDSILL PLATE1x6SILL PLATE2x4 INTERIORWALL2x_ TREATEDBLOCKING1/2" GYP. BD.1/2" GYP BD LEDGE6-1/2" CAP BOARDSHOE PERIMETERWINDOW FRAMEEXTERIOR SHEATHINGR-10 EXTERIORINSULATIONR-5 INTERIORINSULATION (IFREQ'D PER CODE)1/2"=1'-0"FLOOR DETAILDENSE PACK FIBERGLASS3/4" SUBFLOOR6" ROUND DUCTWORKMANUFACTURED I-JOISTSR-8 INSULATION WRAPNETR-30 SPRAY FOAM INSUL.4.34" AROUND DUCTWORK(R-6.9 PER INCH)BLOWN-IN INSULATION1" CLOSED-CELLSPRAY FOAM5/8" GYP. BD.9'-1 1/8"10'-3 7/8"9'-8 3/4"8'-2"8'-1 1/8"6'-8"1'-4"10 1/8"1'-4"10 1/8"6'-8"7-1/4"12" 4"PERMIT/CONSTRUCT PLANS4660 172ND STREET WEST LOT 6 BLOCK 10 - BROOKSHIRE FOUNDATION DETAILAT FOOTING STEP LOCATIONS1FG1DescriptionDateRevisionProject Number:Date:FG11Sheets: of2Print Name:Signed: License Number:Nick Hanson46665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.January 1, 20244.0011-1-242024 FOUNDATION GUIDEWALL SECTIONWALKOUT WALL CONDITION2FG1WALL SECTIONLOOKOUT WALL CONDITION3FG1WALL SECTIONEXTERIOR UNBALANCED FILLCONDITION4FG1WALL SECTIONFULL HEIGHT WALL CONDITION5FG1REBAR TABLE6FG1SITE ADDRESS:City:State:Zip:MNCOPYRIGHT HANSON GROUP LLC 2024©DRAWING USE GUIDELINES AND LIMITATIONSTHE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THISPACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE.THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THEPROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS.THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT INACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEWAND INSPECTIONS.LIMITATIONS1.BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOPOF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT).2.STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT.3.OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITESPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED.4.STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST ORSTRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED.5.EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS.6.ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURALENGINEERING DOCUMENTS.COLD WEATHER GUIDELINES:1.THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILLADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONALCEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED ATTEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F.2.DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHENPOSSIBLE.3.DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS ISRECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR INCONTACT WITH FROZEN MATERIALS.4.REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE.5.BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLSWHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALLWHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F.**THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHERREQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE.MATERIALSCONCRETE WALLS:F'c = 3000 PSI @ 28 DAYSMIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIERCONCRETE FOOTINGS:F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDESA WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE.AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX.REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40#5+ BARS - ASTM A615 GRADE 60TREATED SILL PLATE:SYP GRADE #2 OR BETTERALLOWABLE SOILBEARING PRESSURE1,500 PSF MINIMUMGENERAL NOTES1.DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVESTRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLYSUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESSADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERALCONTRACTOR.2.STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS.3.112" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS.4.STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIPFOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE.5.PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS.6.SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEETUNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED.7.BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, ANDINSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTEDOTHERWISE.8.ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALLTHICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS.9.REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BARDIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET.10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVERIS ACHIEVED ON ALL SIDES.11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS.12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN.VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS.13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINORFORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS.14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONSARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALLCORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS INLENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELSMAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHTFOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOADTRANSFER OVER A SILL PLATE OVERHANG CONDITION.15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1.16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITHTHE MANUFACTURER'S REQUIREMENTS.17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS.18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL ANDDIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICALREINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED,BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDINGIS ACHIEVED.19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING.MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS.20.THESE DRAWINGS ARE INTENDED TO BE A LIMITED COMPONENT DESIGN TO RESIST LATERAL SOILPRESSURES FOR SINGLE FAMILY RESIDENCES. VERTICAL LOADS AND FOOTING DESIGNS ARE TO BE THERESPONSIBILITY OF THE BUILDING DESIGNER. NO SUPPLEMENTAL ENGINEERING OR COMPONENT DESIGNFOR THE FOUNDATION SYSTEM SHALL BE INCLUDED WITH THIS PACKET WITHOUT THE PRIOR REVIEW ANDCONSENT OF THE HANSON GROUP.EQUIVALENT REBAR TABLEFOR BUNDLED HORIZONTAL BARS(2)#4 = (1)#6(3)#4 = (2)#5(3)#5 = (2)#6GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE 5/FG1)BACKFILL HEIGHT(SEE 5/FG1)7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10"12"8"10"12"8"10"12"NONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24"24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)(2) #4 HORIZONTAL BARSBOTH TOP & BOTTOMEXTENDED AT LEAST 24"BEYOND EACH END OF STEPSTABLE BANKHIGH FOOTING MAY BEEXTENDED PROVIDEDBARS ARE PLACED ASSHOWNHORIZ. BARSTOP & BOTTOM6" MIN THICK CONCRETEFOUNDATION, SEE OTHERDETAILS FOR MORE INFOOPTIONAL CONTROL JOINTAT EACH END OF STEP72" MAX SPANEQ.EQ.24" MINDETAIL B3" MIN TYPCONCRETE STRIPFOOTING11BDETAIL A36" MINSTEP2 x STEPSTEP NOTE:DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEPLOCATIONS SHOWNREAR FROST WALLLOOKOUTWALLFULL HEIGHTWALLGARAGE FROSTWALLELEVATIONSHOWN FORREPRESENTATIONPURPOSES ONLY-MAY NOT APPLYELEVATIONSTEP SPACING REQUIREMENTSATYP.6"MIN.WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAYFROM FOUNDATIONOPTIONAL STEM WALLMINIMUM THICKNESS TOMATCH SILL PLATESILL PLATE TO MATCHFRAME WALL ABOVE16" MAX FOR 4" THICK STEM24" MAX. FOR 6" THICK STEMSLAB-ON-GRADE BY OTHERS(1) #4 x CONTINUOUSHORIZONTAL BAR ATTOP OF WALL6" MIN. C.I.P. CONCRETEFOUNDATION WALLUNREINFORCED CONCRETESTRIP FOOTING SEE 5/FG1#4x2'-0" DOWELS @ 72" O.C. MAX(5" MIN. EMBED) DOWELS ARENOT REQUIRED IF BACKFILL ISPLACED EQUALLY ON BOTHSIDES IN LIFTS NOT TO EXCEED24"-ALTERNATE EACH SIDE6"MIN.3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN.EMBED) CENTERED IN WALL @48" O.C. (SAND SOIL)OR 36" O.C. (SANDY-CLAY SOIL)OR 24" O.C. (CLAY SOIL)DOWELS MUST BE WET SET ORDRILLED AND EPOXY GROUTED6" MIN. THICK C.I.P.CONCRETEFOUNDATION WALLSLOPE GRADE AWAYFROM FOUNDATION12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORS(1) #4 x CONTHORIZONTAL BARAT TOP OF WALLFRAMING & SILLPLATE BY OTHERSSLAB-ON-GRADEBY OTHERSUNREINFORCED CONCRETESTRIP FOOTING SEE 5/FG1(18" MIN WIDTH FOR CLAYBACKFILL OR 16" MIN WIDTH IF2'-6" MAX UNBALANCED BACKFILL)SCOPE OF DRAWINGS:THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED ANDCERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESEDRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P.CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANTTO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR.THESE DRAWINGS EXPIRE ON DECEMBER 31, 2024.6"MIN. CLEAR HEIGHT BACKFILL HEIGHT112" CLEARUNREINFORCED CONCRETESTRIP FOOTING PER CODEOR BY BUILDING DESIGNER,AS AN ALTERNATIVE GUIDEUSE TABLE SHOWN BELOW8" MIN. C.I.P. CONCRETEFOUNDATION WALL-SEEREBAR TABLE 6/FG1 FORVERTICAL REBARANCHOR BOLTS SEE WALLANCHOR INFO ON 2/FG2FLOOR TO SILLCONNECTION SEE 1/FG2WOOD FLOORSYSTEM BY OTHERSSLOPE GRADE AWAYFROM FOUNDATION2x6 MIN SILL PLATECLEAR HEIGHT OF 8'-0" OR LESS(2)#4xCONT. HORIZONTAL BARSCLEAR HEIGHT OF 8'-0" OR MORE(3)#4xCONT. HORIZONTAL BARSCONCRETESLAB-ON-GRADEPLACED TIGHT TOFOUNDATION WALL#4x2'-0" DOWELS @ 72" O.C.MAX (5" MIN. EMBED)GENERAL STRIP FOOTING SIZE GUIDESOILONE-STORY STRUCTURETWO-STORY STRUCTURE2000 PSF16" WIDE x 8" THICK20" WIDE x 8" THICK1500 PSF20" WIDE x 8" THICK26" WIDE x 8" THICKTHIS TABLE IS A GENERAL FOOTING SIZE GUIDE FOR TRIBUTARY UNIFORM LOADING ONLY BASED ONMAXIMUM 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS AND IS TO BE VERIFIED BY HOME DESIGNER. FURTHERCONSIDERATION IS TO BE TAKEN BY HOME DESIGNER FOR VENEER WEIGHT, WALL THICKNESSES OVER 10",AND FLOOR AND ROOF DEAD LOADS OVER 15 PSF. CONCENTRATED LOADS FROM GIRDER TRUSSES, BEAMS,HEADERS, ETC. ARE TO BE ACCOUNTED FOR AND SIZED INDEPENDENTLY OF THIS GUIDE BY OTHERS.6'-0" MAX WOOD FRAMINGABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAY FROMFOUNDATION AT A GRADUAL 2%SLOPE PER GENERAL NOTE 6SILL PLATE TO MATCHFRAME WALL ABOVE#4 x CONTINUOUS HORIZONTALBARS @ 24" O.C. TYP.OPTIONAL 2" RIGID INSULATION ONINSIDE FACE AND UNDERSLAB-ON-GRADE FOR 24" MIN.UNREINFORCED CONCRETESTRIP FOOTING SEE 5/FG1(DROP FOR FROST ASREQUIRED PER SITE DESIGN)#4x2'-0" DOWELS @ 48" O.C.MAX (5" MIN. EMBED)(1) #4 x CONTINUOUS HORIZONTALBAR AT TOP OF WALLOPTIONAL SLAB LEDGECONCRETE SLAB-ON-GRADE8" MIN. C.I.P. CONCRETEFOUNDATION WALL#4 x 5'-0" HOOKS @ 24" O.C.EMBEDDED IN FOUNDATIONWALL & CAST INTO SLAB(MAY REDUCE 2'-0" LEG LENGTH& DRILL IN & EPOXY 8" MIN.INTO FOUNDATION WALL)3'-0"NO HOOKS @ 3'-0" OR LESS GRANULAR MATERIAL (SAND)DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0"#5 VERTICAL BARS @ 24" O.C.CENTERED IN WALL TO AID INTHE REDUCTION OF CRACKINGAND BACKFILLING ISSUES PRIORTO TOP OF WALL PINNINGCONTRACTOR IS TO PROVIDETEMPORARY TOP OF WALLBRACING UNTIL GARAGESLAB-ON-GRADE IS IN PLACE(HOOKS INTO GARAGE SLABPROVIDE REQUIRED TOP OFWALL LATERAL SUPPORT)2'-0"8'-0" OR LESS9'-0" MAX.10'-0" MAX.5851 Cedar Lake RoadSuite 202St. Louis Park, MN 55416Tel 612-708-3572www.hansongroupmn.comD R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 COPYRIGHT HANSON GROUP LLC 2024©DescriptionDateRevisionJanuary 1, 2024Project Number:Date:4.001FG22Sheets: of2Print Name:Signed: License Number:Nick Hanson1-1-2446665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.CONNECTION INFOTOP OF WALL CONNECTION TOFLOOR SYSTEM1FG2BRICK LEDGE INFO5FG2WALL SECTIONAT WINDOW WELL LOCATIONS6FG2STOOP INFO7FG2WALL ANCHOR INFOANCHOR BOLT AND ALTERNATIVESPACING2FG2BLOCKING DETAILFLOOR JOIST CONDITION3FG2BLOCKING DETAILFLOOR TRUSS CONDITION4FG2SITE ADDRESS:City:State:Zip:MNVENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATIONWALL SEE5/FG1WOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS16" HIGH MAX x6" THICK MINSTEM6"MINWOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS6" MIN THICK STEM#4 DOWELS @ 36" O.C.EMBEDDED 24" INTOLOWER WALLFOUNDATIONWALL SEE5/FG1VENEER ORSLAB-ON-GRADEBY OTHERS12"VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 2/FG1 OR 3/FG1FRAMING BYOTHERS16" HIGH MAXx 4" THICK MINSTEMTHICKNESS TOMATCH SILLPLATE6"3'-0" MAX VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 4/FG1SLAB-ON-GRADEFRAMING BYOTHERS6" MIN THICKSTEMDETAIL @ HIGH GRADESIM @ NON-BEARINGDETAIL @ LOOKOUTSIM @ FROST WALLDETAIL @ FROST WALLSw/ LOW GRADEDETAIL @ LOW GRADESIM @ NON-BEARING112"CLEARMINMAX#4 DOWELS @36" O.C.EMBEDDED 24"INTO LOWERWALL (CENTERIN STEMWALL)6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICKx 2"Ø OR SQUARE WASHER SEE 2/FG2FOR SPACING (7" EMBED MIN)-METAL STRAP ANCHORS TO BEINSTALLED AT MANUFACTUREREQUIVALENT SPACINGFLOOR SYSTEM, TYPE,SIZE, AND SPACING TO BEDETERMINED BY OTHERSRIM BOARD OR BRACINGMATERIAL BY OTHERS2x6 SILL PLATE MINIMUMFLOOR TO SILL CONNECTION ATEACH MEMBER SEE TABLE BELOWWASHER TO BE COUNTERSUNKFLUSH w/ TOP OF SILL PLATESEE FULL HEIGHT WALL SECTIONON 5/FG1 FOR FOUNDATION WALLREQUIREMENTSSLOPE GRADE AWAYFROM FOUNDATIONMINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS****BACKFILL TYPECLEAR HEIGHT(SEE 5/FG1)FLOOR MEMBERSPACING16"19.2"A(4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBERSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)24"16"19.2"24"16"19.2"24"AAAAAAABAABBBBBCCCDDDDDDDCCONNECTION A(4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC ATEACH MEMBERCONNECTION CCONNECTION D(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ**OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS*ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/FG1)BACKFILL HEIGHT(SEE 5/FG1)7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS72"* 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWNSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS72"72"72"72"72"72"72"72"72"72"72"72"48"60"72"48"60"72"36"48"72"36"36"72"72"72"48"24"24"ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS**ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/FG1)BACKFILL HEIGHT(SEE 5/FG1)7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS48"** APPLIES TO 12"Ø EXPANSION BOLT w/ 6" EMBED, 12"Ø SELF-CUTTINGANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHORSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS60"72"30"36"72"18"24"42"72"72"24"18"20"24"18"24"24"30"42"16"12"14"16"12"16"36"36"N/AN/ASLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONNOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER.WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES.* FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES,FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE.** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH.*** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s.****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE ASTRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE.2x8 SILL PLATE TO BE USED w/MAXIMUM OF 112" OVERHANG(MAINTAIN 234" EDGE DISTANCETO BOTH CONCRETE AND INSIDEOF SILL PLATE) - VERTICAL LOADTRANSFER BY SUPPLIERNAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR@ BLOCKING SEE 1/FG22 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWNOR SHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE 2/FG2 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1.MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2.NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3.BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4.BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5.HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE 1/FG22 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAYFROM FOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1.MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2.NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3.BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4.BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5.HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE 2/FG2 FOR SPACING OFBLOCKING SYSTEM SHOWN10'-0" MAX 3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB 1'-6" MIN 3'-0" EACH WAY MIN112" TYP SLOPE GRADE AWAYFROM FOUNDATION#4 HORIZONTAL BARS @12" O.C. CENTERED INWALLS LAP AROUNDCORNERS AND HOOKINTO FOUNDATION WALL@ EACH SIDE (REFER TO5/FG1 FOR HORZ. BARREQUIREMENTS w/ 8"C.I.P. WALLS)6" MIN C.I.P.CONCRETE WALL#4 VERTICAL BARS @EACH OUTSIDECORNER OF WELL(1)#4 x2'-0" DOWEL @EACH OUTSIDECORNER OF WELL (5"MIN EMBED)12" WIDE x 8" THICK MINSTRIP FOOTING(1) #4 HORIZONTALBAR AT TOP OF WALL(2) #4 HORIZONTAL BARSTOP & BOTTOM OFLINTEL EXTEND 24" MINPAST OPENING EACHEND (WOOD OR STEELOPTION BY OTHERS)WALL BEYONDPLACE (2) #4 VERTICALBARS FULL HEIGHT ANDONE ANCHOR w/IN 12" OFOPENING EACH END8" MIN C.I.P.CONCRETE WALLSLAB-ON-GRADEUNREINFORCED CONCRETESTRIP FOOTING SEE FULLHEIGHT WALL SECTION 5/FG1LOOKOUTWALLSEE 3/FG1GRANULARMATERIAL(SAND)SLOPEWINDOW WELLLADDER/ESCAPEMEANS BYOTHERS5'-0" EACH WAY MAXFLOOR SYSTEM BY OTHERS(DO NOT PLACE GIRDERS ORBEAMS OVER CONCRETE LINTELDESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL ATTHE DISCRETION OF THE BUILDER FOR ADDITIONALFROST PROTECTION AS REQUIRED PER SITE DESIGN6"MIN.BACKFILL HEIGHT (NOT TO EXCEED 10'-0")SEE 5/FG1 FOR TYPICALFOUNDATION WALL &FOOTING CONSTRUCTIONMAINTAIN MIN. 6" WIDESTEMWALL WITHEXTERIOR LEDGEWOOD FLOORSYSTEM BY OTHERSBACKFILL BELOW EXTERIORSTOOP SLABS WITH COMPACTEDGRANULAR MATERIAL TO FROSTDEPTH (4'-0" MINIMUM)FLASHING &WATERPROOFINGBY OTHERSSTOOP SLAB BY OTHERS* SEE 1/FG2 FOR FLOORTO SILL CONNECTION112" CLEARBUILD UP w/ RIGIDINSULATION BELOW SLABTO MAINTAIN 10'-0" MAX.BACKFILL HEIGHT ASREQ'D OR PROVIDE SITESPECIFIC ENGINEERING(MAY SUBTRACT 6" FOR USE IN TABLE LIMITS FOR SANDY CLAY & CLAY SOILS DUE TO GRANULAR FILL BELOW STOOP SLAB) * MODIFIED CLEAR HEIGHT* SEE REBAR TABLE 6/FG1FOR VERTICAL REBAR* SEE 2/FG2 FOR ANCHOR BOLTS* FOR REBAR TABLE 6/FG1, FLOOR TO SILL CONNECTION TABLE 1/FG2, AND ANCHOR BOLT TABLE 2/FG2USE MODIFIED CLEAR HEIGHT OF 9'-0" IN TABLES FOR BACKFILL HEIGHTS UP TO 8'-6" ANDUSE MODIFIED CLEAR HEIGHT OF 10'-0" IN TABLES FOR BACKFILL HEIGHTS UP TO 9'-6"(MAY REDUCE BACKFILL HEIGHT BY 6" FOR USE IN TABLE LIMITS FOR SANDY CLAY AND CLAY SOILS)8'-0" OR LESS9'-0" MAX.10'-0" MAX.8'-0" OR LESS9'-0" MAX.10'-0" MAX.8'-0" OR LESS9'-0" MAX.10'-0" MAX.5851 Cedar Lake RoadSuite 202St. Louis Park, MN 55416Tel 612-708-3572www.hansongroupmn.comD R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 ProductsPlotID Net Qty ProductLength PliesB1 4 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 4' 0" 2B2 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 10' 0" 2UNEXCAVATEDOPTIONAL EGRESSWINDOW HEADER(3) 1-3/4"X7-1/4"X6'VERSA LAM LVLSTAIRWAYFLOOR TRUSSESBY OTHERSPORCH FLOORBY OTHERSB1B2B147' 0"31' 0" 10' 0"19' 6"17' 6"29' 0"26' 0" 22' 0" 2' 0" 19' 0" 5' 0" 18' 0"ProductsPlotID Net Qty ProductLength PliesB1 4 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 6' 0" 2B2 1 Beam by others 6' 0" 1B1B2B147' 0"ProductsPlotID Net Qty ProductLength PliesB1 2 1-3/4" x 7-1/4" VERSA-LAM® 2.0 3100 SP 4' 0" 2B2 2 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP 8' 0" 2B3 1 Beam by others 8' 0" 1B1B2B347' 0"Sheet: 1 of 3DWG: Basement BeamsFile: Plan #5490-B3-GLBy: Anthony EstevezDate: 10-30-15Scale: 1/4" = 1' - 0"BC FRAMERD.R. HORTONBoise Building Material DistributionLakeville, MN (952) 469-5900SALES PRESENTATION DRAWINGNo structural or dimensional check has been made of this designdrawings of the building, therefore purchaser is to check andapprove all dimsensions, quantities, loads, and details carefully.This drawing has not been check by Boise Engineering.NOTE:ALL MEASUREMENTSTO BE VERIFIEDIN THE FIELD.12-1-18AERevisions:BY:"BEAM BY OTHERS" TO BE ADOUBLE 2X10 SPF #2SUPPLIED BY OTHERS,UNLESS NOTED OTHERWISE.NOTE:ALL HEADERS REQUIRE NOLESS THAN 3" OF BEARINGAT EACH END. UNLESSNOTED OTHERWISE.PLAN #5490-B3-GLD.R. HORTONBASEMENT BEAMSDESIGN = L/360BASE MODELBASEMENT BEAMSWALKOUT OPTIONLOOKOUT OPTIONDETAIL N/A SCOPEDESIGN AND DETAILING OF A RETAINING WALL TYPE STAIRWAY FOUNDATION WALL FOR ASINGLE FAMILY RESIDENCE. CONSTRUCTION IS TO BE DONE IN ACCORDANCE WITH THESEDRAWINGS AND STANDARD INDUSTRY PRACTICE.GENERAL NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO HOUSE PLANS FOR MOREINFORMATION.2.THE HANSON GROUP'S ENGINEERING IS LIMITED TO THE ITEMS LISTED IN THE PROJECTSCOPE ABOVE. THE DESIGN OF THE REMAINING HOME IS BY OTHERS.3.CONTRACTOR AND BUILDER ARE TO VERIFY ALL DIMENSIONS AND CONDITIONS BEFOREPROCEEDING WITH WORK. NOTIFY THE HANSON GROUP IF DISCREPANCIES ARISE.4.DRAIN TILE, DAMPPROOFING AND/OR WATERPROOFING, & INSULATION, AS WELL AS THEIRINSTALLATION, ARE TO BE IN ACCORDANCE WITH THE CODE.5.INSTALL A MINIMUM OF (2) ANCHORS PER PORTION OF SILL PLATE AS WELL AS ANANCHOR WITHIN 12" OF EACH END AS APPLICABLE.6.BAR SPLICES ARE TO BE LAPPED A MINIMUM OF 48 BAR DIAMETERS. PROVIDE 48"MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS ANDINTERSECTIONS.7.CARE IS TO BE TAKEN DURING BACKFILLING TO MAINTAIN A PLUMB WALL ALIGNMENT.8.BULKHEAD FOOTINGS FOR RETAINING WALL TYPE FOUNDATIONS AT STEP LOCATIONS. DONOT JUMP FOOTINGS.9.ADEQUATE SHORING IS THE RESPONSIBILITY OF THE CONTRACTOR.10.STAIR FOUNDATION WALL IS TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING.MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS. MAINTAIN LATERALBRACING UNTIL BASEMENT SLAB IS PLACED AND CURED.MATERIALSCONCRETE FOOTINGS: F'c = 5,000 PSI @ 28 DAYS (OR 3,000 PSI WITHAN APPROVED ADMIXTURE THAT PROVIDESA WATER AND VAPOR RESISTANCE AT LEAST EQUIVALENT TO 5,000 PSI CONCRETE)CONCRETE WALLS: F'c = 3,500 PSI @ 28 DAYSREINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40#5+ BARS - ASTM A615 GRADE 60AGGREGATE: FOOTINGS - 112" MAX WALLS/SLABS- 34" MAXON-SITE SOIL:ANY OF THE FOLLOWINGSAND (TYPE I) geq = 30 PSF/FT (ACTIVE)SANDY CLAY (TYPE II) geq = 45 PSF/FT (ACTIVE)CLAY (GROUP III) geq = 60 PSF/FT (ACTIVE)ALLOWABLE SOILBEARING PRESSURE: 2,000 PSF (ASSUMED)LOADSROOF LIVE LOAD: 35-42 PSF (SNOW)ROOF DEAD LOAD:15 PSFFLOOR LIVE LOAD:40 PSFFLOOR DEAD LOAD:15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODES2020 MINNESOTA RESIDENTIAL CODEPARTIAL LOWER LEVEL PLAN SHOWNFOR LOCATION REFERENCE ONLY(ACTUAL LAYOUT MAY BE MIRRORED)1F1REFERENCE PLAN WALL SECTION 2F1 RETAINING WALL TYPESTAIRWAY FOUNDATION WALL2 F1 ALONG STAIR STANDARD 8'-4" TALL BASEMENTFOUNDATION WALLS &CONNECTIONS TO FLOORFRAMING PER FOUNDATIONGUIDELINE DRAWINGS TYP.COPYRIGHT HANSON GROUP, LLC 2022©DescriptionApril 6, 2022Project Number:Date:0.144F11Sheets: of1D R Horton 20860 Kenbridge Court #100Lakeville, MN 550445490 ModelAll ElevationsMN Construction3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.DateRevisionPrint Name:Signed: License Number:Garrett Brunell4-6-2252600Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.(3) #4 LONGITUDINAL BARSAT TOP OF FOOTING#4 HORIZ. BARS@ 24" O.C.8" MIN. C.I.P.CONCRETE WALLVERTICAL BAR OPTIONS:#5 BARS @ 24" O.C.OR #6 BARS @ 36" O.C.#4 BARS @ END &BEND OF HOOK5'-0" HOOK OPTIONS:#5 HOOKS @ 12" O.C. OR#6 HOOKS @ 18" O.C.TRANSVERSE BARS OPTIONS:#5 BARS @ 24" O.C. OR#6 BARS @ 36" O.C.10" THICK C.I.P.CONCRETE FOOTING1'-6"3'-6"2" TO VERTICAL BARS & HOOKS1'-6"4'-0"2" 3" 8'-4" MAX.SLAB-ON-GRADE WOOD WALL 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 48" O.C. MAX. OR EQUIV.FRAME WALL ABOVESLAB-ON-GRADE &INSULATION BY OTHERS6" MIN. C.I.P. CONCRETESTEM WALL COPYRIGHT HANSON GROUP, LLC 2020©THIS SHEET/S REPRESENTS A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRERESIDENTIAL STRUCTURE. THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WINDRESISTING ELEMENT THAT IS REQUIRED FOR THE HANSON GROUP'S DESIGN IS SHOWN ON THE STRUCTURALDRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TOROOF TRUSSES ABOVE, TO JOISTS/TRUSSES/BLOCKING ABOVE, AND TOJOISTS/TRUSSES/BLOCKING BELOW. THESE PANELS ARE NOT NECESSARILYREQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR JOISTS)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.EXTERIOR NON-BEARING WALLFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUMSHEATHING BOTH FACES WITH EITHER FASTENER OPTIONLISTED IN NOTE 3, SPACED AT 4" O.C. PROVIDE INCREASEDFASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TOBE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)INDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ONEXTERIOR FACE IN ACCORDANCE w/ NOTE 2. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.(MIN. LENGTH)w/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESMATERIALSWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLSL:134" WIDTH - 1.55E OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLOADSROOF SNOW LOAD: 35-42 PSFROOF DEAD LOAD: 15 PSFFLOOR LIVE LOAD: 40 PSFFLOOR DEAD LOAD: 15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODE2020 MINNESOTA RESIDENTIAL CODEHARDWAREALTERNATETABLESIMPSONPRODUCTUSPPRODUCTA34MP34A35MPA1H2.5RT7HTT5HTT45LSTASTRAPSAMELTP4MP4FMSTCSTRAPSAMESTHD14/RJSTAD14/RJTITEN HDWEDGEBOLTHARDWARE IN SAMEROW MAY BE USEDINTERCHANGEABLYIN THIS DOCUMENTROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIPNAIL BOTTOM PLATETO RIM/JOIST/BLOCKING w/ (3) 16dNAILS EVERY 16"NAIL BOTTOM PLATETO RIBBON BRACE /TRUSS w/ (3) 16dNAILS EVERY 16"NAIL EACH JOIST TOTOP PLATES w/ (3)0.131"Ø x 3" NAILS2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHNAIL EACH TRUSS TOTOP PLATES w/ (3)0.131"Ø x 3" TOENAILSROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"NAIL RIM TOPPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO LADDERTRUSS w/ (3) 16dNAILS EVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/0.131"Ø x 3"NAILS @ 6" O.C.INTERIOR WALLPERPENDICULAR TO FRAMINGINTERIOR WALLPARALLEL w/ FRAMING2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN JOISTSNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH JOIST TO TOPPLATE w/ (3) 0.131"Ø x 3" NAILSNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN TRUSSESNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH TRUSS TO TOP PLATEw/ (3) 0.131"Ø x 3" TOENAILSPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE JOIST DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSS DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.DescriptionApril 2, 2020Project Number:Date:0.144S11Sheets: of1D R Horton 20860 Kenbridge Court #100Lakeville, MN 550445490-B-GL ModelMinnesota Construction3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.DateRevisionPrint Name:Signed: License Number:Ryan Mack10-7-2046673Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.SCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM FOR A SINGLE-FAMILY RESIDENCE. CONSTRUCTION ISTO BE IN ACCORDANCE WITH THIS DOCUMENT, STANDARD INDUSTRY PRACTICE, AND THE CODE.NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO CONSTRUCTION DOCUMENTS FOR MORE INFORMATION.2.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICHMEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x6 STUDS SPACED @ 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.3.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. ORTYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)4.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS.5.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIP OR EQUIVALENT AND (4) 0.131"Ø x 3"TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.6.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12) 0.131"Ø x 3" INLAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3" FACE NAILS.7.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).8.TALL WOOD WALL FRAMING IS TO BE DESIGNED BY SUPPLIER FOR GRAVITY AND OUT-OF-PLANE WIND LOADS.9.THE ENTRY PORCH IS CONSIDERED TO BE A PRIMARILY OPEN, NON-ESSENTIAL PORTION OF THE STRUCTURE AND ISEXCLUDED FROM THE OVERALL MAIN WINDFORCE SYSTEM OF THE HOME. PROVIDE CODE REQUIRED UPLIFTCONNECTIONS AT ALL POSTS AND TENSION CONNECTIONS AT LEDGERS.CONCRETEFOUNDATIONBELOWSIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWN w/12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHORPOST-INSTALLED HOLDOWN OPTION5S1FRAMING DETAILS1FRAMING DETAILGARAGE FRONT PORTAL FRAME4NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.16'-3"±NOT TO EXCEED 12'-0"FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT STUD EACH END OF HEADERLOCATE PANEL JOINT WITHIN 2'-0" FROMCENTER OF HEADER HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x6 BEARING STUDS MIN.(VERIFY w/ SUPPLIER)PROVIDE 2x6 INFILL WALLABOVE HEADER AS REQ'DSIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 5/S1 FOR ALTERNATIVE OPTION)FOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADER58" Ø ANCHOR BOLT (7" MIN. EMBED)w/ 2" x 2" x 316" PLATE WASHERNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/ (2)ROWS 8d NAILS @ 3" O.C. STAGGERED & TOPLATES / BLOCKING @ 3" O.C.)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.LARGE HATCH AREA INDICATES 716" OR THICKERPLYWOOD OR OSB SHEATHING APPLIED TO EXTERIORSIDE OF STUDS w/ STANDARD 6"/12" NAILINGFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELS1'-712"±CONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN.312" WIDTH & MIN.1114" DEPTH REQ'D)1'-712"±PARTIAL LOWER LEVEL HOUSE PLANSHOWN FOR LOCATION REFERENCE ONLY1S1REFERENCE PLANTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO WALKOUT FOUNDATIONSTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO LOOKOUT FOUNDATIONSUPPER LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY3S1REFERENCE PLAN(4-FT)(4-FT) (4-FT)(4-FT)(4-FT)(4-FT)(4-FT)(4-FT)(4-FT)(4-FT)BRACED WALL LINE BRACED WALL LINE BRACEDWALL LINEBRACEDWALL LINE(4-FT)(4-FT)(4-FT)BRACEDWALL LINE(4-FT)(4-FT)(4-FT)BRACEDWALL LINEMAIN LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY2S1REFERENCE PLANCONSTRUCTPORTAL FRAMEAS SHOWN IN 4/S1(5-FT)(5-FT) (5-FT)(5-FT)(4-FT)(4-FT) (6-FT)(6-FT)(3.5-FT)(2.5-FT)(4-FT)(4-FT)(4-FT)(4-FT)(4-FT)BRACED WALL LINE BRACED WALL LINE BRACEDWALL LINEBRACEDWALL LINE(6-FT)(6-FT)(3.5-FT)(2.5-FT)(4-FT)BRACED WALL LINE BRACEDWALL LINEBRACEDWALL LINEWITH OPTIONAL BEDROOM-BATH-OFFICEPlan Changes10-7-201 AHdr15' 2"2' 0" 4' 4"9' 6"19' 11 5/8"3' 0"By: Anthony EstevezDate: 11-2-15RevisionsFile: Plan #5490Scale: 1/4"=1'DWG: Tall WallSheet: 1 of 1Boise CascadeLakeville, MNGeneral Notes:Boise Cascade Versa Studs shall be installed in accordance with BoiseCascade Corporations Engineered Wood Installation Guide.It is theresponsibility of the framing contractor to adhere to all recommendations forinstallation stated within. Boise Cascade installation guides can be obtained bycontacting a Boise Engineered wood Products specialist at 1-800-281-5503 orvisiting our website at www.bc.com.Design Criteria:Wind Load 20 PSFL/180Blocking @8' o.c. verticallySALES PRESENTATION DRAWINGNo structural or dimensional check has been madeof this design drawing of the building, thereforepurchaser is to check and approve all dimsensions,quantities, loads, and details carefully. This drawinghas not been check by Boise Engineering.1: 3-5-192:3:NOTE:CONTRACTOR IS TO VERIFY ALL DIMENSIONS ANDROUGH OPENING SIZES PRIOR TO ANYCONSTRUCTION OF WALLS. ROUGH OPENINGSIZES ARE ESTIMATES. VERIFY WITH WINDOWMANUFACTURER.NOTE:TALL WALL IS DESIGNED FOR VERTICAL LOADSAND HORIZONTAL WIND LOADS ONLY. LATERALWALL LINE BRACING OF THE BUILDING IS TO BEACCOUNTED FOR BY BUILDING DESIGNER.NOTE:STUDS, COLUMNS, AND HEADERS CALLED OUTREQUIRE LVL MATERIAL. PLATES, CRIPPLES,TRIMMERS, AND BLOCKING LABELED BY OTHERSDO NOT REQUIRE LVL MATERIAL AND ARE NOTINCLUDED IN QUOTE.COLUMN A:(2) 1-1/2"X5-1/2" VERSA STUDSCONNECT COLUMNS TO PLATES WITH 6 - 16D NAILSOR TWO A23 ANGLE CLIPS AT BOTH TOP ANDBOTTOM.COLUMN B:N/AHEADERS:Hdr1 = (2) 2x10 by othersSINGLE TRIMMER REQUIRED FOR SUPPORT ATEACH END OF HEADER AS SHOWN.2x6 WallCOLUMN C:N/ASTUDS:1-1/2"X5-1/2" VERSA STUDS @ 16" OCPLAN #5490 GARAGE LEFTALL ELEVATIONSD. R. HORTONTALL WALL @ STAIRWAYDouble top plateby othersSingle bottom plateby othersOnly upper 6 ft of wallis exposed to wind load. Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 5490 Walkout HVAC Load Calculations for D.R. Horton Lakeville Prepared By: Jake Ryan Silver Tree Plumbing & Heating 1335 Mendota Heights Rd Mendota Heights, MN 55120 651-900-7053 Friday, January 10, 2020 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5490 Walkout Eagan, MN 55121 Page 2 Project Report General Project Information Project Title:5490 Walkout Designed By:Jake Ryan Project Date:1/10/2020 Project Comment: Client Name:D.R. Horton Client City:Lakeville Company Name:Silver Tree Plumbing & Heating Company Representative:Jake Ryan Company Address:1335 Mendota Heights Rd Company City:Mendota Heights, MN 55120 Company Phone:651-900-7053 Company E-Mail Address:jaker@silvertreepandh.com Design Data Reference City:Minneapolis, Minnesota Building Orientation:Front door faces North Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15.33 n/a 30%72 33.90 Summer:88 73 50%50%75 35 Check Figures Total Building Supply CFM:888 CFM Per Square ft.:0.226 Square ft. of Room Area:3,935 Square ft. Per Ton:1,903 Volume (ft³):32,794 Building Loads Total Heating Required Including Ventilation Air:49,084 Btuh 49.084 MBH Total Sensible Gain:19,689 Btuh 79 % Total Latent Gain:5,129 Btuh 21 % Total Cooling Required Including Ventilation Air:24,819 Btuh 2.07 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\New Construction Bids\DRHORTON\5490\Base Calcs\5490 Heat Calc.rh9 Friday, January 10, 2020, 2:09 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5490 Walkout Eagan, MN 55121 Page 3 Load Preview Report Scope Has AED Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Min Htg CFM Min Clg CFM Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.07 1,903 3,935 19,689 5,129 24,819 49,084 585 888 585 888 888 System 1 Main Floor No 2.07 1,903 3,935 19,689 5,129 24,819 49,084 585 888 585 888 888 11x15 Ventilation 664 3,364 4,028 4,981 Supply Duct Latent 6 6 Return Duct 62 111 173 413 Humidification 6,297 Zone 1 3,935 18,963 1,648 20,611 37,392 585 888 585 888 888 11x15 1-Basement 1,312 3,215 0 3,215 11,393 178 151 178 151 151 2--5 2-Main Floor 1,312 7,981 1,048 9,029 13,004 203 374 203 374 374 3--7 3-Upper Level 1,312 7,768 600 8,368 12,994 203 364 203 364 364 3--7 F:\New Construction Bids\DRHORTON\5490\Base Calcs\5490 Heat Calc.rh9 Friday, January 10, 2020, 2:09 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5490 Walkout Eagan, MN 55121 Page 4 Duct Size Preview Room or Duct Name Source Minimum Velocity Maximum Velocity Rough. Factor Design L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size System 1 Supply Runouts Zone 1 1-Basement Built-In 450 750 0.01 0.1 552.2 178 151 151 2--5 2-Main Floor Built-In 450 750 0.01 0.1 466.3 203 374 374 3--7 3-Upper Level Built-In 450 750 0.01 0.1 453.9 203 364 364 3--7 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 775.3 585 888 888 11x15 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:585 Cooling Flow:888 F:\New Construction Bids\DRHORTON\5490\Base Calcs\5490 Heat Calc.rh9 Friday, January 10, 2020, 2:09 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5490 Walkout Eagan, MN 55121 Page 5 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain LOWEE BUILDER GRADE: Glazing-LOWEE BUILDER GRADE, ground reflectance = 0.23, indoor insect screen with 100% coverage, U-value 0.32, SHGC 0.32 357 9,945 0 6,283 6,283 11J: Door-Metal - Fiberglass Core, U-value 0.6 37.8 1,972 0 544 544 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 2633.2 14,893 0 2,277 2,277 15B0-10sf-8: Wall-Basement, , R-10 board insulation to floor, no interior finish, 8' floor depth, U-value 0.05 872 3,794 0 0 0 RJ R-20: Wall-Frame, Custom, RJ R-20 RIM JOIST R20 SPRAY FOAM, U-value 0.05 416.1 1,810 0 364 364 R49 Attic: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Custom, R49 Attic, U-value 0.02 1311.8 2,282 0 1,784 1,784 21A-28: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 28' wide, U-value 0.022 1311.8 2,511 0 0 0 Subtotals for structure:37,207 0 11,252 11,252 People:6 1,200 1,380 2,580 Equipment:448 2,310 2,758 Lighting:950 3,240 3,240 Ductwork:598 117 107 224 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 145, Summer CFM: 145 4,981 3,364 664 4,028 Humidification (Winter) 17.17 gal/day :6,297 0 0 0 AED Excursion:0 0 736 736 Total Building Load Totals:49,084 5,129 19,689 24,819 Check Figures Total Building Supply CFM:888 CFM Per Square ft.:0.226 Square ft. of Room Area:3,935 Square ft. Per Ton:1,903 Volume (ft³):32,794 Building Loads Total Heating Required Including Ventilation Air:49,084 Btuh 49.084 MBH Total Sensible Gain:19,689 Btuh 79 % Total Latent Gain:5,129 Btuh 21 % Total Cooling Required Including Ventilation Air:24,819 Btuh 2.07 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. F:\New Construction Bids\DRHORTON\5490\Base Calcs\5490 Heat Calc.rh9 Friday, January 10, 2020, 2:09 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5490 Walkout Eagan, MN 55121 Page 6 Building Rotation Report All rotation degree values in this report are clockwise with respect to the project's original orientation. Building orientation as entered (zero degrees rotation): Front door faces North Individual Rooms Rm. No. Room Name 0° Rot. CFM 45° Rot. CFM 90° Rot. CFM 135° Rot. CFM 180° Rot. CFM 225° Rot. CFM 270° Rot. CFM 315° Rot. CFM High Duct Size System 1: Zone 1: 1 Basement 151 202 *219 166 106 162 200 186 2--6 2 Main Floor 374 476 *518 430 332 420 473 437 5--6 3 Upper Level 364 431 *447 401 343 393 410 397 4--6 * Indicates highest CFM of all rotations. Whole Building Rotation Degrees Front door Faces Supply CFM Sensible Gain Latent Gain Net Tons 0°North 888 19,689 5,129 2.07 45°Northeast 1,108 24,384 5,130 2.46 90°East *1,183 *25,982 5,130 *2.59 135°Southeast 997 21,999 5,130 2.26 180°South 782 17,408 5,130 1.88 225°Southwest 975 21,543 5,130 2.22 270°West 1,083 23,844 *5,130 2.41 315°Northwest 1,020 22,496 5,130 2.30 * Indicates highest value of all rotations. 1.8 2.0 2.2 2.4 North Northeast East Southeast South Southwest West NorthwestCooling TonsDirection Front door Faces Building Rotation Tonnage Building Net Tonnage F:\New Construction Bids\DRHORTON\5490\Base Calcs\5490 Heat Calc.rh9 Friday, January 10, 2020, 2:09 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Silver Tree Plumbing & Heating 5490 Walkout Eagan, MN 55121 Page 7 Building Rotation Report (cont'd) 20,000 21,000 22,000 23,000 24,000 25,000 26,000 27,000 28,000 29,000 30,000 31,000 32,000 33,000 34,000 35,000 8 am 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pmBuilding Net Gain, BtuhTime of Day Building Rotation Hourly Net Gain Front door faces North Front door faces Northeast Front door faces East Front door faces Southeast Front door faces South Front door faces Southwest Front door faces West Front door faces Northwest F:\New Construction Bids\DRHORTON\5490\Base Calcs\5490 Heat Calc.rh9 Friday, January 10, 2020, 2:09 PM NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 Alexis Flores 2/12/24 X PM