Loading...
HomeMy WebLinkAbout17961 Hinckley Ave-SurveyHINCKLEY AVENUE4 17961 Hinckley Ave 1057. 9 5 1058. 7 1 1060.63 1060. 0 6 1056.5 4 1049. 3 7 U I IIIIII>>>>>>>>>>>>>>>>>>>>>>>>> >>>>>>>>>IIIIIII>>>>>>>PROPOSED WALKOUT PROPOSED GARAGE PROPOSED DRIVEWAY 6.3% SLOPE Building Setback Drainage and Utility Easement N:178137.23 E:519531.44N:178122.76 E:519415.94 T/C=1056.27 EX CB I=1051.16 (12" RCP) W I=1050.93 (18" RCP) S I=1050.72 (18" RCP) NE T/C=1056.42 EX CB I=1052.16 (12" RCP) E I=1044.42 (12" ) EE R=1044.50 EX CB I=1041.13 (12" PVC) N I=1041.20 (12" PVC) S R=1049.72 EX CB I=1046.37 (12" ) N R=1055.14 EX SAN MH I=1043.02 (12" RCP) S I=1042.88 (12" RCP) N 11.2711.2711.2711.27S89°13'41"W 130.00 N89°13'41"E 130.00 S00°46'19"E 72.53N00°46'19"W 72.53510 10 5730 25 72052.5 29.5 25.5 1060.501052.501 0 5 2 . 5 0 1 0 5 9 . 5 5 10 6 0 . 7 0 10 6 0 . 2 1 106 0 . 7 0 1060.701057.971059.111048.95106 0 . 0 4 10 5 6 . 4 4 1 0 4 4 . 7 3 6.006.010.012.462.0 20.0048.00 50.0044.00 12.004.00 5.541 0 5 8 . 8 09.832.0 6.00 1052.021056.991060. 2 0 1055. 1 0 105210501048106010 6 0 105610541052.001 0 5 1 . 9 91056.93HP1060.50HP10 5 2 . 2 8 Exposed Foundation 10 5 6 . 2 5 1059 . 5 5 PORCH2.29105 4 . 0 0 1058.3425303 L4 B5 DATE REVISION SCHEDULE DESCRIPTION BY PROJECT NO. CAD FILE NAME DRAWN BY DESIGNED BY ORIGINAL ISSUE DATE CLIENT PROJECT NO. REVIEWED BY PROJECT SHEET TITLE WITHOUT PRIOR WRITTEN CONSENT. INC. AND MAY NOT BE USED, COPIED OR DUPLICATED THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,FILE LOCATION: S:\PROJECTS\25000 PROJ\25300-25399\25303 STREEFLAND PROPERTY - LENNAR - LAKEVILLE MN\25303 CIVIL-SURVEY\SURVEY PRODUCTION DRAWINGS\LOT CERTS\BLOCK 5\LOT 4\25303 L4 B5.DWG 1OF CERTIFICATE OF SURVEY 1 21-25303 LAKEVILLE MINNESOTA JW MAS LENNAR CORPORATION CASLANO LOT 4, BLOCK 5 I HEREBY CERTIFY THAT THIS SURVEY, PLAN, OR REPORT WASPREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. DATE LIC. NO.2/7/24 45817 MARK A. SCHWANZ CONSTRUCTION NOTES: 1.Install rock construction entrance. 2.Install silt fence as needed for erosion. 3.Sidewalks shall drain away from house a minimum of 1%. 4.Contractor must verify driveway design. 5.Contractor must verify service elevation prior to construction. 6.Add or remove foundation ledge as required. GENERAL NOTES: 1.Grading plan by ISG last dated May 9, 2022 was used to determine proposed elevations shown hereon. 2.This survey does not purport to show improvements or encroachments, except as shown, as surveyed by ISG or under my direct supervision. 3.Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4.No specific soil investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5.If building footprint exceeds the building pad, additional earthwork and testing will be required to meet the requirements as outlined within the geotechnical report. 6.This certificate does not purport to show easements other than those shown on the recorded plat. 7.Bearings shown are based on the Final Plat. 8.Site address is 17961 Hinckley Avenue, Lakeville, MN 55044 9.House/Basement type: Snelling EH06 D3 - Right - Walkout 10.Building dimensions shown are based on First Floor Plan. 11.Proposed Contours are shown hereon. 12.Topographic survey was completed on January 22, 2024. BENCHMARK: Top nut fire hydrant located in the NE quadrant of Hideaway Trail and Highview Avenue. Elevation = 1038.03 feet AREA TABLE: House/Garage Area = 2,283 sq. ft. Porch Area = 157 sq. ft. Driveway/Walk Area = 908 sq. ft. Total Impervious Area = 3,348 sq. ft. Lot Area = 9,429 sq.ft. Impervious Coverage = 35.5% HOUSE ELEVATIONS:Proposed/As-Built Garage Floor = 1060.7 Top of Foundation = 1061.0 Lowest Floor = 1053.0 Lowest Opening = 1053.0 0 SCALE IN FEET 10 20 Note: Cut and fill quantities include building excavation, driveway, and lot grading. GRADING QUANTITIES (CY) Calc Common Cut -144 Calc Common Fill 212 Driveway*-24 Basement Slab -40 Contracted Amount -50 Additional Amount -0 Sand -7 Swell 20%42 Total Cut -265 Total Fill 254 Total (±)-11 1/26/24 Re-Stake new house layout JW 982 982 . 5 985.0 5 LEGEND Existing Building Sanitary Line Water Line Storm Line Set Lath at Property Corner Cleanout Curb Stop Manhole/Catch Basin Utility Pedestal Offset Iron Existing Contour Proposed Contour Proposed Spot Elevation Existing Spot Elevation Surface Drainage Direction > >> I U