Loading...
HomeMy WebLinkAboutLA222007-APPROVED-19475 Holt Ct Solar PlanCOVER SHEETPHOTOVOLTAIC ROOF MOUNT SYSTEM19475 HOLT CT,LAKEVILLE,MN 55044, USAREVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-0 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comROOF TYPE: - COMP SHINGLENUMBER OF LAYERS: - 01ROOF FRAME: - 2"X4" RAFTERS @ 24" O.C.STORY: - TWO STORYSNOW LOAD : - 50 PSFWIND SPEED :- 115 MPHWIND EXPOSURE:- BEXPOSURE CATEGORY:- IICO-ORDINATES:- 44.667225, -93.241460DESIGN CRITERIA:2VICINITY MAPSCALE: NTSPV-01AERIAL PHOTOSCALE: NTSPV-0PV-0COVER SHEETPV-1SITE PLAN WITH ROOF PLANPV-2ROOF PLAN WITH MODULESPV-3ATTACHMENT DETAILSPV-4 ELECTRICAL LINE DIAGRAMPV-5 PLACARDS & WARNINGPV-6+EQUIPMENT SPEC SHEETSSHEET INDEXGOVERNING CODES:PROJECT SITEARRAY LOCATIONGENERAL NOTES·ALL ELECTRICAL WORK SHALL BE PERFORMED BY A QUALIFIED LICENSEDELECTRICIAN AND/OR APPRENTICES WORKING UNDER THE DIRECTSUPERVISION OF THE LICENSED CONTRACTOR.·ALL WORK CARRIED OUT SHALL COMPLY WITH THE SPECIFICATIONS,APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCALJURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS.·PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL NOTIFYTHE ENGINEER OF AN DISCREPANCIES NOTED AMONG SITE CONDITIONS,MANUFACTURER RECOMMENDATIONS, OR AUTHORITY HAVING JURISDICTION. IFTHE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESEDRAWINGS, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER OF RECORD AWRITTEN "RFI"(REQUEST FOR INFORMATION) PROPOSING AN ALTERNATIVE ORSEEKING CLARIFICATION.·THE CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OFPLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THEPREMISES AT ALL TIMES.·UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHINGMATERIALS, EQUIPMENT, ACCESSORIES, AND LABOR NECESSARY TO COMPLETEALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.·ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCEWITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTORSHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS,ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLICAUTHORITY REGARDING THE PERFORMANCE OF WORK.·THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS INACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESSSPECIFICALLY STATED OTHERWISE.·CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA,ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BEAFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TOALL OSHA REQUIREMENTS AND THE LOCAL JURISDICTION.·FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FORALL ROOF WORK.·WHEN INSTALLING IN FIRE RATED AREAS, SEAL ALL PENETRATIONS WITH ULLISTED MATERIALS APPROVED BY LOCAL JURISDICTION. CONTRACTOR SHALLKEEP AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS.·CONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION. ALL DEBRIS ANDOTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN ALAWFUL MANNER.·THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS,CURBS, LANDSCAPING AND STRUCTURES NOT PART OF THE SCOPE OF WORKAS IDENTIFIED IN THESE PLANS.·THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FORTHE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION.·DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY AREEXPOSED TO LIGHT, CONTRACTOR SHALL DISABLE THE ARRAY DURINGINSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, ORCOVERING ARRAY WITH AN OPAQUE COVER ACCORDING TO MANUFACTURER'SINSTRUCTION.·CONSTRUCTION LOADING ON THE ROOF, SUCH AS MATERIAL STAGED ON THEROOF, SHALL BE LIMITED TO 20 PSF. CONCENTRATED LOADING SHALL BEAVOIDED TO PREVENT LOCALIZED DAMAGE TO THE ROOF.13 MODULES-ROOF MOUNTED - 5.20 kWDC, 4.54 kWAC2023 NATIONAL ELECTRICAL CODE2018 MINNESOTA STATE BUILDING CODE2020 MINNESOTA RESIDENTIAL CODE2020 MINNESOTA FUEL GAS CODE2020 MINNESOTA MECHANICAL CODE2020 MINNESOTA ENERGY CONSERVATION CODE2020 MINNESOTA FIRE CODESYSTEM SUMMARY:(N) 13 - SILFAB PRIME SOLAR SIL-400HC+ (400W) MODULES(N) 13 - ENPHASE ENERGY IQ8A-72-2-US MICRO-INVERTERS(N) JUNCTION BOX(E) 225A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER(N) 60A FUSED AC DISCONNECT(N) PRODUCTION METER(N) ENPHASE IQ COMBINER 4EXISTING SYSTEM SUMMARY:(E) 26 - JA SOLAR JAM60S12-310/PR (310W) MODULES(E) 26 - SOLAR EDGE P400 POWER OPTIMIZER(E) 1 - SOLAR EDGE SE7600H-US INVERTER(E) 60A NON-FUSED AC DISCONNECT(E) PRODUCTION METER26 EXISTING MODULES-ROOF MOUNTED - 8.06 kWDC, 7.60 kWACConcept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode03/07/2024jnuetzman JB41'-4"18'-9"~167.40'~108.55'~141.98'~46.40'~32.77'ACDMSPUMCBPVMINVPVMACDJB19'-0"5'-4"ACDMSPUMCBPVMINVPVMACDSITE PLAN WITH ROOF PLANREVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-1 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSITE PLAN WITHROOF PLAN1SCALE: 1/16" = 1'-0"NOTE:3/4" OR GREATER EMT CONDUITRUN INSIDE ATTICHOLT CTEXISTINGDRIVEWAY ROOF ACCESS POINTLEGENDAC DISCONNECTJUNCTION BOXMAIN SERVICE PANELPV PRODUCTION METERTREESACDJBMSPPVMENPHASE IQ COMBINER 4X2-IQ-AM1-240-4 (IEEE 1547:2018)CBUTILITY METERUMVENT, ATTIC FAN (ROOF OBSTRUCTION)PROPERTY LINEINVERTERINVAC DISCONNECTACDPV PRODUCTION METERPVMTWO-STORYHOUSEPROPERTY LINEPROPERTY LINE PROPERTY LINEPROPERTY LINE(N) 3/4" OR GREATER EMTCONDUIT RUN (INSIDEATTIC)(E) 26 - JA SOLAR JAM60S12-310/PR (310W) MODULESNOTE:NO FENCE OR GATE IN THISPROPERTY 3'-4"10'-4"5'-1"17'-4"2"8"12'-8"4'-3"ACDMSPUMCBPVMINVPVMACDJBREVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-2 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comROOF PLAN WITHMODULESROOF PLAN WITH MODULESSCALE: 1/8" = 1'-0"1PHOTOVOLTAIC MODULESSILFAB PRIME SOLARSIL-400HC+ (400W)MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 13 MODULESMODULE TYPE = SILFAB PRIME SOLAR SIL-400HC+ (400W)MODULESMODULE WEIGHT = 47 LBS / 21.4 KG.MODULE DIMENSIONS = 75.3"X 40.8" = 21.34 SFUNIT WEIGHT OF ARRAY = 2.20 PSFNOTE: ACTUAL ROOF CONDITIONS AND RAFTERS &TRUSSES (ORSEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FORATTACHMENTS· PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED.SYSTEM SIZE:- 13 x 400W = 5.200 kWDC 13 x 349VA = 4.537 kWAC40.8"75.3"NOTE: THE AC DISCONNECT IS LOCATEDWITHIN 10FT OF UTILITY METERNOTE:3/4" OR GREATER EMT CONDUITRUN INSIDE ATTICARRAY AREA & ROOF AREA CALC'SROOF# OFMODULESARRAYAREA(Sq. Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVERED BYARRAY (%)#113277.36635.6243.64ROOF DESCRIPTIONROOF TYPECOMP SHINGLE ROOFROOFROOFTILTAZIMUTHRAFTERSSIZERAFTERSSPACING#134°270°2"X4"24" O.C.LEGENDVENT, ATTIC FAN(ROOF OBSTRUCTION)ROOF ATTACHMENT UNIRAC FLASHLOC @48" O.C.AC DISCONNECTJUNCTION BOXACDJBMSPMAIN SERVICE PANELNXT UMOUNT RAILENPHASE ENERGY IQ8A-72-2-USMICRO-INVERTERSENPHASE IQ COMBINER 4X2-IQ-AM1-240-4 (IEEE 1547:2018)CBPV PRODUCTION METERPVMUTILITY METERUMRAFTERSFIRE PATHWAYBILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONRAIL7NXT UMOUNT RAIL 168" DRKRAIL SPLICE2NXT UMOUNT RAIL SPLICEUNIVERSAL CLAMP34NXT UMOUNT COMBO CLAMP DRKROOFATTACHMENTS33UNIRAC FLASHLOCACCESSORIES16NXT UMOUNT RL & CLMP CAP KITMLPE & GROUNDING17NXT UMOUNT MLPE & LUG CLAMPARRAY AREA & ROOF AREA CALC'SAREA OFNEWARRAY(Sq. Ft.)AREA OFEXISTINGARRAY(Sq. Ft.)AREA OF NEW& EXISTINGARRAY(Sq. Ft.)AREA OFROOF(PLANVIEW)(Sq. Ft.)TOTAL ROOFAREACOVERED BYARRAY %277.36468.61745.972578.7828.93%INVERTERINVAC DISCONNECTACDPV PRODUCTION METERPVMHOLT CT FRONT YARD REAR YARD18" FIRE PATHWAY18" FIRE PATHWAY36" FIRE PATHWAY36" FIRE PATHWAYROOF #1TILT - 34° AZIMUTH - 270°(N) (33) UNIRAC FLASHLOC ATTACHMENTSSPACED AT 48 O.C.(E) 2"X4" RAFTERS @ 24" O.C. (TYP.)(E) COMP SHINGLE ROOF (TYP.)(E) 26 - JA SOLAR JAM60S12-310/PR (310W) MODULES(N) ENPHASE ENERGY IQ8A-72-2-USINVERTERR324.6.2 Setback at Ridge: For photovoltaicarrays occupying not more than 33% of theplan view total roof area, not less than an18" clear setback is require don both sidesof a horizontal ridge. For photovoltaic arraysoccupying more than 33% of the plan viewtotal roof area, not less than a 36" clearsetback is required on both sides of ahorizontal ridge.Please note, if additional panels areinstalled in the future, you will be required toadjust placement of the existing panels andnew to provide the 36" clear ridge path. REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-3 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comATTACHMENTDETAIL2"X4" RAFTERS @ 24" O .CENLARGE VIEWPV MODULESCOMP SHINGLE ROOF2.5" MIN.EMBEDMENT5/16" x 4" STAINLESS STEEL LAG BOLTW/ SS EPDM BONDED WASHERNXT UMOUNT COMBO CLAMPPV MODULES NXT UMOUNT RAIL STRONGHOLD RAIL CLAMPFLASHLOC BASEROOF / DECK MEMBRANECOMP SHINGLE ROOF5/16"-18 x 2"SERRATED FLANGE HEX SCREW~4" HEIGHTADJUSTMENT1.37"~4"1.37"ATTACHMENT DETAILSCALE: NTS1ATTACHMENT DETAIL (ENLARGED VIEW)SCALE: NTS2NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM)LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FORATTACHMENTS REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-4 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comELECTRICAL LINEDIAGRAME AS PER YOUR REQUIREMENTELECTRICAL LINE DIAGRAM WITH CALCULATIONSCALE: NTS1NOTE: THE AC DISCONNECT IS LOCATEDWITHIN 10FT OF UTILITY METER·GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION, LOAD CENTER, AND/OR DISCONNECTS. DISCONNECTSSHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ (AUTHORITY HAVING JURISDICTION). PV INSTALLATIONSHALL COMPLY WITH ALL APPLICABLE CODES.·WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUN TO INVERTER.·PER NEC REQUIRMENTS GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE PROTECTED IN A CONDUIT,RACEWAY, OR ARMORED PROTECTIVE SHEATHING (NEC 250.64).·THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICALEQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26.·ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT. (NEC 300.6 C1, 310.8 D).·ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP.·ALL CONDUIT SHALL BE EMT 3/4" IN DIAMETER UNLESS OTHERWISE STATED.UTILITY PROVIDER:MAIN SERVICE VOLTAGE:MAIN PANEL BRAND:MAIN SERVICE PANEL:MAIN CIRCUIT BREAKER RATING:MAIN SERVICE LOCATION:SERVICE FEED SOURCE:DAKOTA ELECTRIC240VN/A(E) 225A(E) 200ASOUTHSERVICE INFO.UNDERGROUNDNOTE:3/4" OR GREATER EMT CONDUITRUN INSIDE ATTICSYSTEM SIZE:- 13 x 400W = 5.200 kWDC 13 x 349W = 4.537 kWACINVERTER SPECIFICATIONSMANUFACTURER / MODEL #QUANTITYNOMINAL OUTPUTVOLTAGENOMINAL OUTPUTCURRENTENPHASE ENERGY IQ8A-72-2-US13240 VAC1.45AAMBIENT TEMPERATURE SPECIFICATIONSRECORDLOW TEMPAMBIENT TEMP(HIGH TEMP 2%)CONDUCTORTEMPERATURERATE-27°32°90°SOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #VMPIMPVOCISCTEMPERATURECOEFFICIENTOF Voc# OFMODULESSILFAB PRIME SOLAR SIL-400HC+(400W)36.0511.1043.0211.58-0.28%/°C13MODULE DIMENSION75.3" L x 40.8" W x 1.37" DNOTE-EQUIPMENT RATED AT 75 DEGREESDCAC#2#1#6(E) JUNCTIONBOX#2#1#712 MODULES IN STRING #214 MODULES IN STRING #1GG(E) AC DISCONNECT 60ANON-FUSED,VISIBLELOCKABLE LABELEDDISCONNECT, 240 VACNNL2L1L2L1M(E) PV PRODUCTIONMETERLINELOADL200ALINE SIDE TAP(E) MAIN BREAKER200A/2P, 240V(E) MAINSERVICE PANEL,225A RATED,120/240VEXISTINGGROUNDINGSYSTEMBI-DIRECTIONALUTILITY METER1-PHASE, 3-W,120V/240V, 60HzC(13) ENPHASE ENERGYIQ8A-72-2-US MICRO-INVERTERS(240V)(LOCATED UNDER EACH PANEL)(N) JUNCTION BOX6 MICRO-INVERTERS IN BRANCH #2GL1L1L2L2N20AGTERMINATOR CAP ON LASTCABLE CONCECTOR Q- CABLE(TYP)10A/15A20A7 MICRO-INVERTERS IN BRANCH #1L1L1L2L2ABM*IQ-GATEWAY(N) ENPHASE IQCOMBINER BOX 4X2-IQ-AM1-240-4(IEEE 1547:2018) [240V](N) AC DISCONNECT 60AFUSED,VISIBLE LOCKABLELABELED, WITH 30A FUSES,240 VACGNNL2L1L2L130A FUSESM(N) PV PRODUCTIONMETERLINELOAD40AEXISTING WIREEXISTING WIREEXISTING WIREEXISTING WIREEXISTING WIRE(E) EXISTING SOLAREDGE SE7600H-US INVERTERSDCONDUCTOR SCHEDULE AND CALCULATIONSTAGLOCATION DESCRIPTION# OFBRANCHCURRENT (A)#C. CARRYINGCONDUCTORWIRESIZEWIRETYPECOND.RATING (A)AMBIENTTEMPCOND. FILLFACTORDERATEDGROUNDSIZECONDUITTYPECONDUITSIZEWIRE RUNFROMBRANCHMAX. MOD. INBRANCHLENGTHINVERTER OUTPUTCURRENT690.8(A)(1)(A)ABRANCH TO J-BOX271.4512.69212 AWGQ-CABLE300.961.028.806 AWGFREE AIRN/ABJ-BOX TO COMBINER BOX271.4512.69410 AWGTHWN-2400.960.8030.7210 AWGEMT3/4"CCOMBINER BOX TO ACDISCONNECT1131.4523.56310 AWGTHWN350.941.032.908 AWGRMC3/4"DAC DISCONNECT TOINTERCONNECTION1131.4523.5636 AWGTHWN650.941.061.108 AWGEMT3/4"NOTE"LOAD" ON THE BOTTOM OF THE METER IS FOR PV GENERATION"LINE" ON THE TOP OF THE METER IS FOR THE UTILITY(13) SILFAB PRIME SOLARSIL-400HC+ (400W) MODULES(13) ENPHASE ENERGY IQ8A-72-2-US MICRO-INVERTERS(01) BRANCH OF 07 MODULES &(01) BRANCH OF 06 MODULES CONNECTED IN PARALLELPER BRANCH(E) 40A PV BREAKERD REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-5 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comWARNING LABELS &PLACARD WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMLABEL LOCATION:EMT/CONDUIT RACEWAYS(PER CODE: NEC690.31(D)(2)PHOTOVOLTAIC POWER SOURCELABEL LOCATION:POINT OF INTERCONNECTIONPRODUCTION METERNEC 705.12(D)(3) & NEC 705.12(C) / NEC 690.59)NOTES AND SPECIFICATIONS:·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE2023 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONSARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THELOCAL AHJ.·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDSUSING EFFECTIVE WORDS, COLORS AND SYMBOLS.·LABELS SHALL BE PERMANENTLY AFFIXED TO THEEQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN.·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTANDTHE ENVIRONMENT INVOLVED.·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISESPECIFIED.·DO NOT COVER EXISTING MANUFACTURER LABELS.ELECTRICAL SHOCK HAZARDWARNINGTERMINALS ON LINE AND LOADSIDES MAY BE ENERGIZED INTHE OPEN POSITIONLABEL LOCATION:INVERTER(S), AC DISCONNECT(S), ACCOMBINER PANEL (IF APPLICABLE).PER CODE(S): NEC 2023: NEC 690.13(B)& NEC 690.15(C)MAXIMUM AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE: 18.85 AMPS 240 VACLABEL LOCATION:AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTION.PER CODE(S): NEC 2023: 690.54SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWNPV SYSTEM AND REDUCESHOCK HAZARD IN THEARRAY.LABEL LOCATION:MAIN SERVICE PANELPER CODE(S): NEC 2023: IFC 605.11.3.1(1) & 690.56(C)!4"3"PHOTOVOLTAIC SYSTEM AC DISCONNECTMAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION:MAIN SERVICE DISCONNECT / UTILITY METER(PER CODE: NEC 690.13(B))LABEL LOCATION:UTILITY SERVICE ENTRANCE/METER (WITHIN 3'),INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OROTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.PER CODE(S): NEC 2023: 690.56(C)(2)RAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEM!WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENT!LABEL LOCATION:COMBINER BOXPER CODE: NEC 690.31(E)PHOTOVOLTAICAC DISCONNECTLABEL LOCATION:AC DISCONNECTNEC 690.13(B)POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THEFOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN19475 HOLT CT(N) COMBINER BOX(N) PV ARRAYCAUTION !MULTIPLE SOURCES OF POWER(E) UTILITY METER(E) MAIN SERVICE PANEL(E) 60A NON-FUSED ACDISCONNECT(E) PRODUCTION METER(N) FUSED AC DISCONNECT(N) PRODUCTION METER(E) INVERTER REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-6 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEET REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-7 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-8 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-9 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-10 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-11 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-12 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-13 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-14 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-15 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-16 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS REVDATEDESCRIPTIONVERSIONUR11/22/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-17 PROJECT NAMEBUBENDORF 19475 19475 HOLT CT, LAKEVILLE, MN 55044, USA APN# 221853501020 UTILITY: DAKOTA ELECTRIC AHJ: CITY OF LAKEVILLESHEET SIZEANSI B11" X 17"THREE RIVERSCONTRACTING LLC2676 47TH ST E, INVER GROVEHEIGHTS, MN 55076TEL: (563) 202-0018CSLB#: BC760638Email - dan@3riversmn.comSPEC SHEETS