Loading...
HomeMy WebLinkAboutLA223261 - 17756 Ellsworth Dr-Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND MAIN FLOOR1' -8 1/4"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE HEIGHT9' - 1 1/8"GARAGE PLATE HEIGHT10' - 9 3/8"SMARTSIDE SIDING &CORNERS TYP.6" SMARTSIDESTORYBOARDTYP. @ FRONTALUMINUM SOFFIT& FASCIA TYP.SMARTSIDE BOARD & BATTEN TYP. 6" SMARTSIDEFRIEZE TYP.UPPER FLOOR12' -8 1/8"UPPER PLATE20' -9 1/4"UPPER PLATE HEIGHT8' - 1 1/8"6" BUMPED OUT LOUVER 66" x 22" W/ 6" CORBELS TYP.6' - 0"6" / 12"6" / 12"5' - 0"4" SMARTSIDE WINDOW & DOOR TRIM TYP.ADDRESS STONESTONE REQUIRED AT FRONTFRONT ELEVATION SQ.FT. = 457 SQ.FT.25% STONE REQUIRED = 115 SQ.FT.HOUSE STONE = 72 SQ.FT.GARAGE FRONT/ RETURN STONE = 47 SQ.FT.TOTAL STONE @ FRONT = 119 SQ.FT.24" RETURNS TYP.6" 12"8" / 12"8" / 12"SMARTSIDE SIDING& CORNERS @ SIDES & REAR ALUMINUM SOFFIT& FASCIA TYP.6" / 12"6" / 12"SMARTSIDE WINDOW & DOOR TRIM @ SIDES & REAR TYP.6" 12"8" / 12"8" / 12"24" RETURNS TYP.1/4" = 1'-0"A-2011FRONT ELEVATIONTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATION3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN4/25/2024 11:33:58 AMSADIE TRADITIONAL-LOFTL3, B1 -PHEASANT RUN 8TH ADDITION17756 ELLSWORTH DRIVELAKEVILLE, MN 55044A-201OTT4473.28.24 CB90817991060(496)4.3.24 CB4.12.24 CB4.25.24 CB3.27.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3767SADIETRADITIONAL-LOFT1/8" = 1'-0"A-2012RIGHT ELEVATION1/4" = 1'-0"A-2013REAR ELEVATION1/8" = 1'-0"A-2014LEFT ELEVATIONConcept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode04/18/2024jnuetzman 19' - 0"21' - 0"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE 30' - 0"10' - 0"64' - 0"10' - 0"54' - 0"1' - 4 1/2"18' - 3" M.O.1' - 4 1/2"5' - 4"13' - 8"20' - 2"6' - 2"14' - 0"6' - 0"0' - 4"0' - 4"0' - 4"64' - 0"27' - 8"36' - 4"14' - 6 1/4"4' - 2 3/4"4' - 2 3/4"19' - 4 1/4"15' - 2"4' - 2 1/4"9' - 5 1/2"19' - 4 1/4"10' - 9 1/4"10' - 7 3/4"6' - 7"12' - 0"10' - 9 1/4"4' - 0 3/4"6' - 9 1/4"5' - 9 1/2"12' - 7 1/4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 3 1/2" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITESTEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITE0' - 4"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.11' - 8"5' - 10"40' - 0"7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.5' - 10"5' - 10"6' - 2"6x6 TRT'D POST ONCONCRETE BELL FOOTINGMIN. 42" BELOW GRADE (TYP.)29' - 8 3/4"10' - 0 1/2"0' - 2 3/4"40' - 0"4' - 0"50' - 0"20' - 9 1/4"7' - 10"11' - 4 3/4"5' - 9 1/4"LEAVE A 12" GAP IN THE FOOTING FOR PLUMBINGØ16"Ø16"9' - 9 1/4"24" x 24" x 12" CONCRETE FTG.UNREINFORCEDTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATION3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN4/25/2024 11:34:00 AMSADIE TRADITIONAL-LOFTL3, B1 -PHEASANT RUN 8TH ADDITION17756 ELLSWORTH DRIVELAKEVILLE, MN 55044A-401OTT4473.28.24 CB90817991060(496)4.3.24 CB4.12.24 CB4.25.24 CB3.27.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3767SADIETRADITIONAL-LOFT1/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. ** ALL DIMENSIONS ARE TO OUTSIDE OF CONCRETE/ SHEATHING FAMILY ROOMMECHANICAL/STORAGEBATHSUMPW. H.FURNACEAIR EX.UNEXCAVATED18" FLOOR TRUSSESPER MFG. SPACINGSTEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITESTEP FOOTING & FOUNDATIONWALL PER GRADE,VERIFY ON SITE18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACINGUNEX.19' - 0"21' - 0"30' - 0"10' - 0"6' - 5 3/8"13' - 6 5/8"10' - 0"5' - 0"5' - 0"CLOSET24" LINEN22/4 x 6/8R.O. 2' -6" x 6' -11"3' VANITY45040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"SMOKEDET.SMOKEDET.CO DET.36' - 4"27' - 8"64' - 0"6' - 0"6' - 2"14' - 0"20' - 2"5' - 4"13' - 8"64' - 0"10' - 0"54' - 0"14' - 9"4' - 0"4' - 0"19' - 7"11' - 0"3' - 10"5' - 10"19' - 4"R & SH.R & SH.KNEE WALL W/ 14" SPINDLES 3' - 8"8' - 4"16' - 11 3/4"19' - 4 1/4"19' - 4 1/4"13' - 7 3/4"15' - 2"11' - 0"5' - 6"4' - 2"25' - 2 1/4"24' - 9 3/4"FLOORDRAIN5' - 0"36" GAS. F.P.EQEQ28' - 0"60" F.G. SHWR2-11 7/8" LVLDROPPED 4' - 0"13' - 5 1/4"2' - 0"22/4 x 6/8R.O. 2' -6" x 6' -11"BEDROOM #45' - 10"5' - 10"11' - 8"40' - 0"6' - 2"0' - 4"0' - 4"0' - 4"40' - 0"5' - 4 1/2"5' - 5 1/4"14' - 0"52/8 x 6/8R.O. 2' -10" x 6' -11"52/8 x 6/8R.O. 2' -10" x 6' -11"52/8 x 6/8R.O. 2' -10" x 6' -11"10' - 8 1/4"16' - 6 1/2"0' - 9 1/4"12' - 0"DECK ABOVE 29' - 6"10' - 6"0' - 6"6x6 TRT'D POST ONCONCRETE BELL FOOTINGMIN. 42" BELOW GRADE (TYP.)4' - 0"50' - 0"0' - 2 3/4"5' - 9 1/4"9' - 9 1/4"0' - 2 3/4"10' - 0"6' - 0"FLEX ROOMUNFINISHEDFLEX ROOM #2UNFINISHED42/6 x 6/8R.O. 2' -8" x 6' -11"45040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"2' - 0"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.LEAVE A 12" GAP IN THE FOOTING FOR PLUMBINGSET FIREPLACE ON FLOOR 2-2x102-2x103-2x103-2x103-2x10 TRT'D12.0' OF WALL BRACING REQUIRED, BRACE TO FOUNDATION OR UNTIL MINIMUM IS MET 15.0' BRACED WALL REQUIRED 52' - 0" (BRACED WALL LINE SPACING)40' - 0" (BRACED WALL LINE SPACING)12.0' BRACED WALL REQUIRED 12.0' BRACED WALL REQUIRED 12.0' OF WALL BRACING REQUIRED, BRACE TO FOUNDATION OR UNTIL MINIMUM IS MET CS-WSP2' - 6" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP8' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES42/6 x 6/8R.O. 2' -8" x 6' -11"0' - 4"2" FOAM INSULATION BETWEEN WALL & SLAB 2x10 TRT'D@ 16" O.C.THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATION3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN4/25/2024 11:34:02 AMSADIE TRADITIONAL-LOFTL3, B1 -PHEASANT RUN 8TH ADDITION17756 ELLSWORTH DRIVELAKEVILLE, MN 55044A-402OTT4473.28.24 CB90817991060(496)4.3.24 CB4.12.24 CB4.25.24 CB3.27.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3767SADIETRADITIONAL-LOFT1/4" = 1'-0"A-4021LOWER FLOOR PLANFAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). 1218' x 8' O.H. GARAGE DOORPRIMARY SUITEGREAT ROOMDININGKITCHENBATHFOYERGARAGECOVEREDPORCHCO DET.SMOKEDET.ATTICACCESSMUDRM.LAUNDRY5' - 6"13' - 6"CLOSET30' - 0"10' - 0"10' - 0"54' - 0"1' - 6"18' - 0"1' - 6"28' - 0"36' - 0"64' - 0"6' - 0"6' - 9"6' - 9"56050E NVG1R.O. 6' -0" x 5' -0"H.H. 6' -10"BOTTOM OF WINDOW FRAMED @ 44" A.F.F 337' - 0"14' - 9 3/8"8' - 2 5/8"5' - 0"5' - 0"14' - 9 3/4"21' - 2 1/4"64' - 0"6' - 0"2A-90114' - 5"4' - 0"4' - 0"19' - 7"KNEE WALL W/ 14" SPINDLES 4" CONCRETE SLAB, SLOPETOWARDS DOOR5/8" TYPE X GYP. BD. CEILING 1/2" GYP. BD. ON GARAGE WALLS R-38 MIN. INSULATION IN FLOOR ABOVEGARAGE PLATE HEIGHT TO MATCHMAIN FLOOR UNLESS NOTED OTHERWISE88050E NVGER.O. 8' -0" x 5' -0"H.H. 6' -10"MFG. ROOF TRUSSESPER MFG. SPACINGSMOKEDET.ROOM -IN ATTIC TRUSSESPER MFG. SPACING20' - 7 1/4"29' - 4 3/4"6' - 0"6' - 0"8' VANITY.CO DET.SMOKEDET.SMOKEDET.ATTICACCESS36" REF36" COOKTOPW/ WOODHOOD ABOVESINK20' - 6"6' - 6"14' - 0"DW6' - 0"24"x14" LINEN2x612/4 SHWR DR.2' - 0"EQEQ63/0 x 6/8R.O. 3' -2" x 6' -11"32/4 x 6/8 PKT105/0 x 6/8R.O. 5' -2" x 6' -11"22/4 x 6/8R.O. 2' -6" x 6' -11"63/0 x 6/8R.O. 3' -2" x 6' -11"73/0 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"BENCHW/ HOOKS4' - 6"7' - 0"4' - 0"4' - 6"R & SH.2'-6" VANITYR & SH.333650 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 7' -0"H.H. 8' -0"3CO DET.SMOKEDET.42" WALL W/ GLASS PANEL ABOVE R & SH.R & SH.TILE SHOWER R & SH.R & SH.SINK15' - 0"6' - 6"3' - 10 3/4"10' - 7 1/4"6' - 4"3' - 4"4' - 3"11' - 0"3' - 10"5' - 10"0' - 10"18' - 6"5' - 11 1/2"5' - 4 1/2"5' - 4"4' - 2 1/4"6' - 0"4' - 1 3/4"63/0 x 6/8R.O. 3' -2" x 6' -11"6' - 4 1/4"4' - 1 3/4"9' - 0"12' - 7"2' - 6"6' - 6 1/2"63/0 x 6/8R.O. 3' -2" x 6' -11"KNEE WALL W/ 14" SPINDLES 63/0 x 6/8R.O. 3' -2" x 6' -11"BUILT-INBUILT-IN2x663/0 x 6/8R.O. 3' -2" x 6' -11"6' - 4 1/4"0' - 11"6' - 11"ATTICACCESS3' - 3"2' - 9"SNACK BAR OVEN/MICRO63/0 x 6/8R.O. 3' -2" x 6' -11"63/0 x 6/8R.O. 3' -2" x 6' -11"83/0 x 6/8 HALF VIEW2' - 6"3' - 6"STACK W/DCOUNTER W/BASE9' - 1"4' - 1 1/2"2' - 6"2x623636 NVG1R.O. 3' -6" x 3' -6"H.H. 7' -2"5' TUB/SHWRPRIMARYCLOSETEN SUITE0' - 9"4' - 0"0' - 9"21' - 0"19' - 0"40' - 0"12' - 0"BEDROOM #26' - 5"1' - 4"KNEE WALL W/ 14" SPINDLES 60" LINEAR ELEC. F.P.50' - 0"4' - 0"29' - 6"10' - 6"40' - 0"0' - 6"10' - 0"CANT. ROOF TRUSSES ABOVE 116/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"DECKU.C. LIGHTS U.C. LIGHTS U.C. LIGHTS U.C. LIGHTS 16' - 0"SHOWER SEAT SHAMPOO SHELF 12020 NVA1R.O. 2' -0" x 2' -0"H.H. 8' -0"2-2x10FLUSH2-9 1/2" LSL FLUSH 18" FLOOR TRUSSESPER MFG. SPACING2-2x10 W/2 TRIMMERS 2-2x10MFG. ROOF TRUSSESPER MFG. SPACING2-2x8 DROPPED 2-2x102-2x10 W/2 TRIMMERS 2-11 7/8" LVL 2-2x102-2x102-2x10 CONT.2-2x10ROOM-IN-ATTIC GIRDER TRUSS ROOM-IN-ATTIC GIRDER TRUSS 3-2x63-2x6MFG. ROOF TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSESPER MFG. SPACING3-2x63-2x63-2x63-2x6CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES25' - 0" (BRACED WALL LINE SPACING)37' - 0" (BRACED WALL LINE SPACING)6.4' BRACED WALL REQUIRED 11.5' BRACED WALL REQUIRED 11.5' BRACED WALL REQUIRED 18.6' BRACED WALL REQUIRED 40' - 0" (BRACED WALL LINE SPACING)7.5' BRACED WALL REQUIRED 5.8' BRACED WALL REQUIRED 7.5' BRACED WALL REQUIRED 19' - 0" (BRACED WALL LINE SPACING)21' - 0" (BRACED WALL LINE SPACING)7.5' BRACED WALL REQUIRED 7.5' BRACED WALL REQUIRED 11.5' BRACED WALL REQUIRED 48' - 0" (BRACED WALL LINE SPACING)14' - 0" (BRACED WALL LINE SPACING)CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP5' - 3" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.PFH1' - 6"PFH1' - 6"CS-WSP4' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-PF3' - 9" B.W.P.CS-PF3' - 9" B.W.P.CS-PF1' - 9" B.W.P.METHOD G.B.6' - 0" BOTH SIDES METHOD G.B.8' - 0" BOTH SIDES METHOD G.B.4' - 0" BOTH SIDES METHOD G.B.4' - 0" BOTH SIDES CS-WSP4' - 0" B.W.P.CS-WSP2' - 0" B.W.P.6.4' BRACED WALL REQUIRED ROOM -IN ATTIC TRUSSESPER MFG. SPACINGTYP.0' - 3"RAILING PER CODE 1/4" = 1'-0"A-4031MAIN FLOOR PLANTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATION3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN4/25/2024 11:34:04 AMSADIE TRADITIONAL-LOFTL3, B1 -PHEASANT RUN 8TH ADDITION17756 ELLSWORTH DRIVELAKEVILLE, MN 55044A-403OTT4473.28.24 CB90817991060(496)4.3.24 CB4.12.24 CB4.25.24 CB3.27.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3767SADIETRADITIONAL-LOFT-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).FANFANFANGirder Truss 2' - 2"12' - 10"2' - 6"1' - 6"22/4 x 6/8R.O. 2' -6" x 6' -11"FLAT VAULT FLAT VAULT 2A-9013' VANITY60" F.G. SHWRBASE W/ TILEWALLSKNEE WALL W/ 14" SPINDLES 67036 NVGER.O. 7' -0" x 3' -6"H.H. 6' -10"BATHLOFT40' - 0"10' - 6"19' - 0"10' - 6"6' - 0"6' - 0"42' - 0"20' - 5"4' - 0"4' - 0"19' - 7"10' - 6"4' - 4"6' - 8"8' - 0"10' - 6"CO DET.SMOKEDET.KNEE WALL W/ 14" SPINDLES 9' - 6"9' - 6"54' - 0"6' - 0"48' - 0"ROOM -IN ATTIC TRUSSESPER MFG. SPACINGRESILIENT CHANNELSYSTEM ON CEILING TYP.10' - 6"19' - 0"10' - 6"94/0 x 6/8R.O. 4' -2" x 6' -11"42/6 x 6/8R.O. 2' -8" x 6' -11"9' - 6"9' - 6"40' - 0"77640 NVGER.O. 7' -6" x 4' -0"H.H. 6' -10"ROOM -IN ATTIC TRUSSESPER MFG. SPACINGBEDROOM #39' - 0"5' - 0 3/4"R & SH.SMOKEDET.2x62x6 FURRING WALL 2x6 FURRING WALL 3' - 10"2-2x102-2x10ROOM-IN-ATTICGIRDER TRUSS ROOM-IN-ATTIC GIRDER TRUSS CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.48' - 0" (BRACED WALL LINE SPACING)CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.4.2' BRACED WALL REQUIRED 4.2' BRACED WALL REQUIRED 54' - 0"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATION3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN4/25/2024 11:34:05 AMSADIE TRADITIONAL-LOFTL3, B1 -PHEASANT RUN 8TH ADDITION17756 ELLSWORTH DRIVELAKEVILLE, MN 55044A-404OTT4473.28.24 CB90817991060(496)4.3.24 CB4.12.24 CB4.25.24 CB3.27.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3767SADIETRADITIONAL-LOFT1/4" = 1'-0"A-4041UPPER FLOOR PLAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).FAN 6" / 12"8" / 12"8" / 12"8" / 12"8" / 12"1' - 0"1' - 0"18" OVERHANGS & 12" RAKES TYP.VERIFY HEELS W/ SECTION ON SHEET A-901W/ 6:12 FASCIA LINES TO MATCH 10 ROOF VENTS REQUIRED @ HOUSE 3 ROOF VENTS REQUIRED @ GARAGE 6" / 12"6" / 12"6" / 12"WATER PROOF COATINGFROM GRADE TO TOPOF FOOTING6 MIL POLY V.B., OVERLAP EDGESMIN. 12" & TAPE. SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" RIGID (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSINSULATION & SEALANT TOBE CONT. OVER WALLMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER FLOOR PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.6 MIL. V.B.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" PLYWOODSHEATHINGSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" PLYWOOD SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGE2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATIONRIM JOISTR-20 MIN. SPRAYFOAM INSULATION2" RIGID (R-10)INSULATION*OUTSIDE OF CONCRETEFOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGINSULATION PROTECTION FROMUNDER SIDING TO BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHERE REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANS0' - 8"ALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSS2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATION3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN4/25/2024 11:34:07 AMSADIE TRADITIONAL-LOFTL3, B1 -PHEASANT RUN 8TH ADDITION17756 ELLSWORTH DRIVELAKEVILLE, MN 55044A-501OTT4473.28.24 CB90817991060(496)4.3.24 CB4.12.24 CB4.25.24 CB3.27.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3767SADIETRADITIONAL-LOFTWINDOW SCHEDULEWINDOW MARK UNIT MANUFACTURER MODEL COUNT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT COMMENTS1 2020 NVA1 VECTOR ENVISION SERIES 1 2' - 0" 2' - 0" 8' - 0"2 3636 NVG1 VECTOR ENVISION SERIES 1 3' - 6" 3' - 6" 7' - 2"3 3650 NVPWG/3620 NVA1 TEMP. VECTOR ENVISION SERIES 3 3' - 6" 7' - 0" 8' - 0"4 5040E NVG1 VECTOR ENVISION SERIES 2 5' - 0" 4' - 0" 6' - 10"5 6050E NVG1 VECTOR ENVISION SERIES 1 6' - 0" 5' - 0" 6' - 10"6 7036 NVGE VECTOR ENVISION SERIES 1 7' - 0" 3' - 6" 6' - 10"7 7640 NVGE VECTOR ENVISION SERIES 1 7' - 6" 4' - 0" 6' - 10"8 8050E NVGE VECTOR ENVISION SERIES 1 8' - 0" 5' - 0" 6' - 10"ROOM FINISH SCHEDULEFLOOR ROOM NAME FLOOR FINISH AREA PLATE HEIGHT COMMENTSLOWER FLOOR BEDROOM #4 CARPET 148 SF 8' - 2"LOWER FLOOR CLOSET CARPET 37 SF 8' - 2"LOWER FLOOR FAMILY ROOM CARPET 653 SF 8' - 2"LOWER FLOOR FLEX ROOM CARPET 148 SF 8' - 2" UNFINISHEDLOWER FLOOR FLEX ROOM #2 CARPET 306 SF 8' - 2" UNFINISHEDLOWER FLOOR STAIRS CARPET 37 SF 8' - 2"LOWER FLOOR MECHANICAL/ STORAGE CONCRETE 157 SF 8' - 2"FINISH PER CODELOWER FLOOR BATH VINYL 54 SF 8' - 2"MAIN FLOOR BEDROOM #2 180 SF 9' - 1 1/8"MAIN FLOOR COVERED PORCH 33 SF 9' - 1 1/8"MAIN FLOOR PRIMARY CLOSET CARPET 54 SF 9' - 1 1/8"MAIN FLOOR GARAGE CONCRETE 466 SF 10' - 9 3/8" FINISH PER CODEMAIN FLOOR PRIMARY SUITE CONCRETE 190 SF 9' - 1 1/8"MAIN FLOOR CLOSET LVP 36 SF 9' - 1 1/8"MAIN FLOOR DINING LVP 132 SF 9' - 1 1/8"MAIN FLOOR FOYER LVP 144 SF 9' - 1 1/8"MAIN FLOOR GREAT ROOM LVP 291 SF 9' - 1 1/8" BOX VAULTMAIN FLOOR KITCHEN LVP 251 SF 9' - 1 1/8"MAIN FLOOR LAUNDRY LVP 60 SF 9' - 1 1/8"MAIN FLOOR MUDRM. LVP 59 SF 9' - 1 1/8"MAIN FLOOR BATH LVT 48 SF 9' - 1 1/8"MAIN FLOOR EN SUITE LVT 103 SF 9' - 1 1/8"MAIN FLOOR DECK TREX 103 SF 9' - 1 1/8"UPPER FLOOR BEDROOM #3 CARPET 229 SF 8' - 1 1/8"UPPER FLOOR LOFT CARPET 455 SF 8' - 1 1/8"UPPER FLOOR BATH VINYL 44 SF 8' - 1 1/8"DOOR SCHEDULE R/O'STYPE MARK DOOR SIZE COUNT ROUGH WIDTH ROUGH HEIGHT COMMENTS1 2/4 SHWR DR. 12 2/4 x 6/8 4 2' - 6" 6' - 11"3 2/4 x 6/8 PKT 14 2/6 x 6/8 3 2' - 8" 6' - 11"5 2/8 x 6/8 3 2' - 10" 6' - 11"6 3/0 x 6/8 8 3' - 2" 6' - 11"7 3/0 x 6/8 FIRE RATED 1 2' - 10" 6' - 10 1/4"8 3/0 x 6/8 HALF VIEW 19 4/0 x 6/8 1 4' - 2" 6' - 11"10 5/0 x 6/8 1 5' - 2" 6' - 11"11 6/0 x 6/8 SLIDER 2 6' - 0" 6' - 8"12 18' x 8' O.H. GARAGE DOOR 11/8" = 1'-0"A-5011ROOF PLAN3/8" = 1'-0"A-5012TYP. POURED WALL SECTION,1/2" = 1'-0"A-5013TYP. POURED WALKOUT SECTION1/2" = 1'-0"A-5014TYP. POURED LOOKOUT SECTION1/2" = 1'-0"A-5015TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5016TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-50110GARAGE CEILING1/2" = 1'-0"A-5019BEARING WALL SECTION3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM: FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALMAIN FLOOR1' -8 1/4"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -8 1/8"UPPER PLATE20' -9 1/4"6' - 7 1/2"5' - 6 7/32"5' - 6 7/32"22" BOTTOM CHORD ROOM-IN-ATTIC TRUSS UPPER PLATE HEIGHT 8' - 1 1/8"EN SUITEGREAT ROOMKITCHENBATHLOFT8" 12"8" 12"1' - 7"VERIFY HEELS W/ TRUSS SUPPLIER 1' - 3"1' - 3 "1' - 7"2' - 0"2' - 0"10' - 6"19' - 0"10' - 6"TRUSSTRUSS1/2" OSB2x6 FURRING WALL 1/2" OSB2x6 FURRING WALL MAIN PLATE HEIGHT 9' - 1 1/8"18" FLOOR TRUSSES FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP. FASTENKING STUD TO HEADERW/ 6-16d SINKERS.MIN. 7/16" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).FRONT ELEVATIONMIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 7/16" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INFRAMING (STUDS AND SILLS) AS SHOWN TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALEXTENT OF HEADER WITH DOUBLE PORTAL FRAMES (TWO BRACED WALL PANELS)BRACED WALL LINECONTINUOUSLYSHEATHED WITH WOODSTRUCTURAL PANELS.OVERLAP0' - 9 1/4" MIN.WOOD STRUCTURAL PANEL SHEATHINGCONTINUOUS OVER BAND OR RIM JOISTNAIL SOLE PLATE TO JOISTPER TABLE R602.3(1)WOOD STRUCTURAL PANEL SHEATHING OVER APPROVED BAND OR RIM JOISTATTACH SHEATHING TOBAND OR RIM JOIST WITH8d COMMON NAILS @3" O.C. TOP @ BOTTOMTHE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:POUR:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATION3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952)-953-4000ONETENTENHOMES.COMTOTAL:P.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN4/25/2024 11:34:09 AMSADIE TRADITIONAL-LOFTL3, B1 -PHEASANT RUN 8TH ADDITION17756 ELLSWORTH DRIVELAKEVILLE, MN 55044A-901OTT4473.28.24 CB90817991060(496)4.3.24 CB4.12.24 CB4.25.24 CB3.27.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR3767SADIETRADITIONAL-LOFT3/8" = 1'-0"A-9011METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/4" = 1'-0"A-9012BUILDING SECTION3/8" = 1'-0"A-9013METHOD CS-PF - RAISED WOOD W/ OVERLAP CUT TOP CHORD18" DEEP TRUSSES24" O.C. BASE SPACING.DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING. TRUSSES HAVE BEEN HELD IN1/2" AT EXTERIOR WALLS FOR SHEATHING.THE PAINTED END DENOTES THE LEFT ENDOF THE FLOOR TRUSS. THIS END OF THEFLOOR TRUSS IS TO BE PLACED WHERE YOUSEE THE TRIANGLE AND THE PAINTED ENDNOTE ON THE PLACEMENT PLAN. THEPAINTED END ALSO CORRESPONDS TO THELEFT SIDE OF THE SEALED TRUSS DRAWING.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBINGLOCATIONS.EXTRA TRUSSES ADDED FOR PLUMBING.SHIFT TRUSSES TO AVOID PLUMBING.DO NOT OVER SPACE TRUSSES.CUT TOP CHORD OF "F11" AT INNER BEARING.DO NOT CUT TRUSSES EXCEPT WHEREINSTRUCTED.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLANDY @ 651-688-3613OREMAIL: ANDY.HOERNEMANN@TRUSSABC.COMF5F3F3F3F3F3F4F13F4F13F4F13F4F13F4F13F3F3F3F3F2F2F2F2F2F1F6F14F14F15F15F15F16F3F17F17F17F9F10F10F10F10F10F11F12F12F12F8F7F1019-04-0416-07-1236-00-006-00-006-00-006-00-0030-00-0010-00-0013-06-006-00-0014-00-006-06-0025-02-0424-09-1250-00-004-00-0040-00-0054-00-008-00-008-00-008-00-008-00-008-00-00Customer: Lyman Lumber - ChanhassenJob Number: 327033-AHome Owner: TOPAZ / SADIE TRADITIONAL / L3, B1 MODELJob Name: RoofSite Address: 17756 ELLSWORTH DR Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Andy Hoernemann2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 4/12/2024Version: 8.5.3.233 HEADER REQUIREDDROPPED?TO CENTERLINE(4) HUS26HHUS48HHUS48HHUS48HHUS48DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING.THE TRUSS ID DOES NOT DENOTE THE LEFTEND OF THE ROOF TRUSS ON THEPLACEMENT PLAN. USE THE LEFT END OFTHE SEALED TRUSS DRAWING AND THETRIANGLE ON THE PLACEMENT PLAN TOLOCATE THE PROPER END OF EACH ROOFTRUSS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLANDY @ 651-688-3613OREMAIL: ANDY.HOERNEMANN@TRUSSABC.COMA2A1A1AAAAAAAE1EEEEE2E2E2A6A5A5A5A4A4A4AAAAA3A3CCCCGJ2J1J1J1J1J1JJJC1C1C1C1CTJ3DDDDV1V2V3V4V5V6V7V8V9V1V2V3V4V5V6V7V8V9P1PPPPPPPPPPP1PPPPPPPPPPP10-00-0030-00-0036-00-0028-00-0021-00-00 5-06-00 13-06-004-00-0050-00-0010-00-004-01-04Customer: Lyman Lumber - ChanhassenJob Number: 327033-AHome Owner: TOPAZ / SADIE TRADITIONAL / L3, B1 MODELJob Name: RoofSite Address: 17756 ELLSWORTH DR Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Andy Hoernemann2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 4/12/2024Version: 8.5.3.233 ! " ! ! # $ $ !% &$$’ ! $ $ ’’ $ $$$" $ $’’ " $$$$ ($ % ))’*%!))’’+,,’%!’’ ’-!’!’%+)%) ’*’!!-!!)’ - , . . ’. % %$ % % %/ . . . !$$&’$0 */’*) $’)$ !%)//0 1/$2/ . !")!00/ ’%+%)//$ 0 $$! 0 1 2 $0$! 0 0 ($ $% ($ % ($ % $ 12&1’2 ’’ $& & ! /$$ / $$ $ $0 $$/$$$00 /$$0 12&1’2 ’ $& ! 12&1’2 ’ $& ! 12&1’2 ’ $& ! 12&1’2 ’ $& ! .+’. $& " 12&1’2 ’ $& ! .+’. $& " 12&1’2 ’ $& ! .’+’. $& " 12&1’2 ’ ’$&$ $& !*.’-*.’-$& " !+ & !/0 12&1’2 ’ & !// $ & ! $!’12 $$ $/$0/))’*%!))’’+,,’%!’’ ’-!’!’%+)%) ’*’!!-!!)’ - , . . ’. % %$ % % %/ . . . !$$&’$0 */’*) $’)$ !%)//0 1/$2/ . !")!00/ ’%+%)//0 $$! 0 1 2 $0$! 0 0 ( 33 ! ’* *%*.’-*.’-* $ / /// $ & $& $ $ $& $ & % /% /& & & + + $0 $ $$ / /0/ +’’ 0/$/ $$/$$/ --$ ’/$$ $& $ & !4 // $/$/// $& $& / $& $& / $& $& $$ + !% $ & ! $!’12 /$/$ * *4 $ $ & $& /% /& $ $& " !+ & ! ))’*%!))’’+,,’%!’’ ’-!’!’%+)%) ’*’!!-!!)’ - , . . ’. % %$ % % %/ . . . !$$&’$0 */’*) $’)$ !%)//0 1/$2/ . !")!00/ ’%+%)//$ 0 $$! 0 1 2 $0$! 0 0 ($ ’ *** Header Spans *** Up to 4' 11" = 1 Trimmer 5' 0" and Larger = 2 Trimmers *** Unless Noted Otherwise *** *** Header Spans *** Up to 4' 11" = 1 Trimmer 5' 0" and Larger = 2 Trimmers *** Unless Noted Otherwise *** *** Header Spans *** Up to 4' 11" = 1 Trimmer 5' 0" and Larger = 2 Trimmers *** Unless Noted Otherwise *** *** Header Spans *** Up to 4' 11" = 1 Trimmer 5' 0" and Larger = 2 Trimmers *** Unless Noted Otherwise *** ||[] [||][]||||||||[[[][] [][]3 - 2x10 3 - 2x10 TRTD 3 - 2x10 2 - 2x10 2 - 11-7/8" LVL Flush 2 - 2x10 $ & + ! % + / / $ 0$ / /% &/ ! ’’ " 0/000/$$$ /0+’’ !) ’ /*! $!’ !% ’ /% &/ +$0$ % + + + ’’ !% + $ ’ $&$& $’ $-- & $& $& + /& /$& $ $& $ & & $& 0 & $& ! ’+ 0 $$ % /%’ $% &0 + $’’ !% ’ +/ 0 / /$/$/$ & $& $0$ $ & $& +’’ & $& ! ! $& & $& $+!% & $& & $& & %’$ +’ ’ !$$ $& $ % & 0 $ /!’ $$!4 $ / +’’ /$ !% & & + ( ))’*%!))’’+,,’%!’’ ’-!’!’%+)%) ’*’!!-!!)’ - , . . ’. % %$ % % %/ . . . !$$&’$0 */’*) $’)$ !%)//0 1/$2/ . !")!00/ ’%+%)//0 $$! 0 1 2 $0$! 0 0 *** Header Spans *** Up to 4' 11" = 1 Trimmer 5' 0" and Larger = 2 Trimmers *** Unless Noted Otherwise *** *** Header Spans *** Up to 4' 11" = 1 Trimmer 5' 0" and Larger = 2 Trimmers *** Unless Noted Otherwise *** *** Header Spans *** Up to 4' 11" = 1 Trimmer 5' 0" and Larger = 2 Trimmers *** Unless Noted Otherwise *** *** Header Spans *** Up to 4' 11" = 1 Trimmer 5' 0" and Larger = 2 Trimmers *** Unless Noted Otherwise *** Room In Attic Girder Truss [] [] Room In Attic Girder Truss MFG Floor Trusses by Others Roof Trussesby OthersRoof Trussesby OthersRoof Trussesby Others2 - 2x10 2 - 2x10 Cont.2 - 2x10 3-2x6 3-2x6 3-2x63-2x6 3-2x6 3-2x6 2 - 11-7/8" LVL 2 - 2x102 Trimmers2 - 2x10 2 - 2x82 - 2x102 - 2x102 Trimmers2 - 2x102 - 9-1/2" LSL Flush2 - 2x10 Flush $$ $ $& $ & % % % ’ !’ ’ +’’ 0 % 0 & ! $$/0 + +’’/& $& $ & $& 0 0 % 0 & !4/+ $& ))’*%!))’’+,,’%!’’ ’-!’!’%+)%) ’*’!!-!!)’ - , . . ’. % %$ % % %/ . . . !$$&’$0 */’*) $’)$ !%)//0 1/$2/ . !")!00/ ’%+%)//0 $$! 0 1 2 $0$! 0 0 ( *** Header Spans *** Up to 4' 11" = 1 Trimmer 5' 0" and Larger = 2 Trimmers *** Unless Noted Otherwise *** *** Header Spans *** Up to 4' 11" = 1 Trimmer 5' 0" and Larger = 2 Trimmers *** Unless Noted Otherwise *** *** Header Spans *** Up to 4' 11" = 1 Trimmer 5' 0" and Larger = 2 Trimmers *** Unless Noted Otherwise *** *** Header Spans *** Up to 4' 11" = 1 Trimmer 5' 0" and Larger = 2 Trimmers *** Unless Noted Otherwise *** Room In Attic Girder Truss Room In Attic Girder Truss Roof Trusses by Others Roof Trusses by Others 2 - 2x10 2 - 2x10 $$$ $$ %$+ %’ ’ .$ %-" % -" ’ %!)% $ %+ $! ! $& ’ ’+ 1 /2 ’" !)!’ !% 1 ’-!2 + ", !%’ % ’ !’$ %! $! %! 12&1’2 ’ $& ! $’ )% ’% /!/!% ’ %$ % %’’ " ’ /4 $’ "$ % !’ ’ $& ! $& " ’$ , $ $1 2 3 ’ !’ / " %!)% $ %+ $! ! $& *’ $& ’ .’+’. $& " 12&1’2 ’ ’$& $& ! + ", / " $! 1 2 ’+ ’ ’ ’ %!)% $ %+ $! ! $& *’ $& ’ ’+ .+’. $& " 12&1’2 ’ $& ! + ", !1 /2 ’" !)!’ !% !%’ $! 1 2 !’ / " 3’ ! $& ’ !1 /2 ’" !)!’ !% 1 ’-!2 % ’ ! %! $! $& " ’$ $! , $ *! 1 2 /!) )- ’ ’ ’’ )% ’% %+1-2 ’ $ ! $& ’ !1 /2 ’" !)!’ !% 1 ’-!2 ! %! $! $& " ’$ $!) , $ *! 1 2 /!) !)- ’ ’ ’’ % ’ ’+! !% %+- ’ /* !) ! !’ $& " !+ & ! + ", %% %!)% $ %+ $! ! / " ))’*%!))’’+,,’%!’’ ’-!’!’%+)%) ’*’!!-!!)’ - , . . ’. % %$ % % %/ . . . !$$&’$0 */’*) $’)$ !%)//0 1/$2/ . !")!00/ ’%+%)/// 0 $$! 0 1 2 $0$! 0 0 ’’ ’’+ ’ $$% % % $ $ $ % % % 0 $ /%’ $% % % 0 /% % % $ / / /% % % / 0 % % % 0 0 0 % % % 0 /% % % / 56789:; !4/ 56 789:; 56789:; 56 789:; ’ 0 $ ’ * $ ’ *4$ $ ’ !4 $ ’ / $ ’ 0 $ ’ /0 $ ’ ! / $ + ! !4$ % $ $ !*% + $/ / / ! !4 $$ // + # ’ $’ $ $& $ $& + $ & $ / $& $ & $ 0 & $ & %’ & $ /& /$ & $ $ & (/ (/ $’) $(/ ’+ $(/ + $(/ /’ $(/ ’ $(/ $(/ !’ !% !! $!%) ! ! % 1 ’2 %! ! ’’’ $!’ ! ’ ’’ ,, ! ! ! $* ’% ! ’ ’!’% !’ !! !% !’ - % .%. ’1$2’ ;+" ’ ! $ 1 2 ) %! !+’ $’ ’ - !$& 1+,+2 !,+ !/$/121$2 !’ %1! 2 % # $*$’! ! 12/! ’ $*$* ’ ) 4!! !/ 1$2$! ’1! 2 ! $/ !$&% ’+’ ’; %#!* 1)!+2 ,+ ! $ ! ’ ;%#!* ’ *) !*’$*’*’ 1!’2 $’ ! $ $ 0$/ 0$/ 0$$$! + ! $ $0%’0$$ ))’*%!))’’+,,’%!’’ ’-!’!’%+)%) ’*’!!-!!)’ - , . . ’. % %$ % % %/ . . . !$$&’$0 */’*) $’)$ !%)//0 1/$2/ . !")!00/ ’%+%)//0 $$! 0 1 2 $0$! 0 0 ( ’’ ( $! Date Certificate Posted X Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here R-15 X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X X R-30 X X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: 70,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93 Cfm's " round duct OR " metal duct Not required per mech. code X Passive Low: Other, describe: X Low: Location of fan(s), describe: Cfm's X " round duct OR 7" flex " metal duct City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 1..5 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.4/26/2024 New Construction Energy Code Compliance Certificate Name of Residential Contractor One Ten Ten Homes, LLC MN License Number Lakeville17756 Ellsworth Drive BC730925 Mechanical room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 65064 Heating Gain Cooling Load 98 Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.27 Appliances THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not Applicable Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.32 Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) GPVL5000L 13ACX024P Model Heating System Natural Gas Lennox Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 14 196 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 19661Residential Load Calculation SEER /EER Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: ML19307016C Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 250 Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 * If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to erosion@lakevillemn.gov “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA)