Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA223614-4880 171st St W-Permit Pack
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND LIGHT FIXTURES1/2"=1'-0"BLOCKING ATThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2022CAT FRONT ONLY1/2"=1'-0"TYPICAL WDW & DOOR TRIM3 1/2" VINYL TRIM 5" VINYL TRIM5" VINYL TRIM3 1/2" VINYL TRIMREFSIDING LEGENDALAP SIDING "B"LAP SIDING "A"PRODUCTCBD5" TRIM - VINYL LINEALNOT USEDE6 1/2" VINYL BEAD BD1.0X20860 KENBRIDGE COURT, SUITE 100LAKEVILLE, MN 55044 (952)985-7272CUST:SPEC HOME A D.R. HORTON COMPANYTYPICAL PORCH COLUMN:6x6 TREATED POST WITHIN10" SQUARE BOXED COLUMN5/4" x 3" - WOODGRAINOVER5/4" x 10" - WOODGRAINWOODGRAIN PANEL5/4" x 3" - WOODGRAIN5/4" x 10" - WOODGRAIN10" SQUARE COLUMN9 1/2"9 1/2"6x6 POSTBLOCKING2x4 TREATED1/2" OSB4/4" x 3" - WOODGRAINCORNER TRIM(FRONT & REAR)4/4" x 2" - WOODGRAINCORNER TRIM(SIDES)4/4" x 3" - WOODGRAINCORNER TRIM(FRONT & REAR)2"=1'-0"1/4"=1'-0"30°A6:12 PITCHHOLCOMBE X42763 SQ. FT. STONE (13.5%)64 SQ. FT. WINDOW (13.7%)XXXXXA1'-0"1xSTEEL PANEL OVERHEAD DOORADDRESS NUMBER6:12 PITCHA8121'-0"9 7/16"4:12 PITCH7'-0"FALSE CORNERRAIN DIVERTER4'-0"1'-0"1'-0"1'-0"1'-0"AABBAA6:121'-0"1'-0"1'-0"1'-0"6:124:12CCDD6:126:12DD1'-0"1'-0"6:126:12VENTROOF20' RIDGE VENTROOF PLAN-5 FT GARAGE1/8"=1'-0"ELEVATION BX427 HOLCOMBEPC#1155: 12-29-23-LLPC#1133,1141,1143: 9-14-2023-LLPERMI/CONSTRUCT:4-24-24-AF7-1/4"12" 4"4" DIA. HOLELEFT ELEVATION1/8"=1'-0"REAR ELEVATION1/8"=1'-0"ASPHALT SHINGLESFLASH OVER ALL EXT OPGS40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R8061'-0"6:12 PITCH1'-0"A1261'-0"6:12 PITCH1'-0"A42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BE1261/8"=1'-0"6:12 PITCH1267 7/16"1261'-0"1'-0"42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BE1266:12 PITCH7 7/16"9 3/4"ELEV W/ ENLARGED GARAGE124124MAINTAIN 6" MIN SEPARATION WOOD to EARTHPERMIT/CONSTRUCT PLANS4880 171ST STREET WEST LOT 8 BLOCK 6 - BROOKSHIRE Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode05/09/2024jnuetzman 6" CURB (OMIT CURB AT GARAGE DOOR OPENINGS)6" THICK, 3'-6" HIGH16"x8" CONC. FTG.POURED CONC. WALLTREATED BOTTOM PLATE4" CURB,16x8 CONC FTGANCHORS AT 6'-0" O.C.2x4 STUDS AT 16" O.C.2x4 BRNG WALL ABOVE14'-0"6'-6"35'-0"41'-6" 16'-3 1/4" 41'-6"21'-0"10'-0"41'-6"2'-4 1/2"16'-3"16'-3" M.O.6'-0" 3'-5 1/2"3'-5 1/2"6'-1"4'-5"7'-3" 16'-11 3/4"9'-8"10'-6"4" 6"6"TREATED BOTTOM PLATE6" WIDE CONC WALL16x8 CONC FTGANCHORS AT 6'-0" O.C.2x6 STUDS AT 16" O.C.2x6 BRNG WALL ABOVEUNEXCAVATED6" CURB, 2" INT. LEDGE,POURED CONC. WALL16"x8" CONC. FTG.10" THICK, 3'-6" HIGH2" GARAGE SLAB LEDGE6" CURB, 2" INT. LEDGE,POURED CONC. WALL16"x8" CONC. FTG.10" THICK, 3'-6" HIGH2" EXT. LEDGE6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 3'-6" HIGH6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 3'-6" HIGH6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 3'-6" HIGH6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 3'-6" HIGHFILL16"x8" CONC. FTG.MIN. 3'-6" BELOW GRADEPOURED CONC. WALL6" THICK15'-0"1'-6"4'-0"4'-6"SEWERCLEANOUTThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2022C2.0XX427 HOLCOMBEPC#1155: 12-29-23-LLPC#1133,1141,1143: 9-14-2023-LLPERMI/CONSTRUCT:4-24-24-AFFOUNDATION PLAN1/4"=1'-0"CONC PAD FTG36x36x12#5 BARS EACH WAY6" CURB, 2" INT. LEDGE,POURED CONC. WALL16"x8" CONC. FTG.10" THICK, 3'-6" HIGH2" GARAGE SLAB LEDGE1'-8"6"FOR KITCHEN ISLANDSLEEVE/CONDUIT6" CURB (OMIT CURB AT GARAGE DOOR OPENINGS)6" THICK, 3'-6" HIGH16"x8" CONC. FTG.POURED CONC. WALL14'-0"6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICKMIN. 3'-6" BELOW GRADEUNEXCAVATED2'-4 1/2"16'-3" M.O.6'-0"5'-0"5'-0"21'-0"2'-0"CONC PAD FTGCONC PAD FTG24x24x824x24x8CONC PAD FTG36x36x12#5 BARS EACH WAY23'-0"18'-6"40'-0"PERMIT/CONSTRUCT PLANS4880 171ST STREET WEST LOT 8 BLOCK 6 - BROOKSHIRE PLAN OPTIONSSLAB ON GRADE 5FT GARAGE BUMPOUT UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2022C3.0XX427 HOLCOMBEPC#1155: 12-29-23-LLPC#1133,1141,1143: 9-14-2023-LLPERMI/CONSTRUCT:4-24-24-AFLIVINGROOMDINING942 SQ. FT.NOTES:-9'-1 1/8" PLATE HEIGHT TYPICAL-WDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)-TYP. FIRST FLOOR WINDOW HEAD HEIGHT AT 7'-11 3/8" U.N.O.-BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFR14'-0"x8'-0"CONC PATIO2ND FLOOR PLAN1/4"=1'-0"NOTES:-8'-1 1/8" PLATE HEIGHT TYPICAL-WDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)-TYP. SECOND FLOOR WINDOW HEAD HEIGHT AT 6'-11 3/8" U.N.O.-BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFR1381 SQ. FT.LIVING AREA1ST FLOOR PLAN1/4"=1'-0"35'-0"9'-4"41'-6" 16'-9"7'-2"18'-6"16x7 OVERHEAD DOOR20'-0"10'-6 1/2"21'-0 1/2"40'-0"11'-6"5'-0"5'-0"2x6 BRNG WALL2x6 BRNG WALL6'-1"20'-0"26'-0"2-8PED.PWDRHD-FLR7'-3 1/2" 3'-6"3'-6"W/ WOOD CAP42" HIGH ANGLED WALLUP 16 R14'-0"2W 3050 SH3050 SH6'-6"6'-6"4'-10 1/4"3'-6"BEDRM #1LAU.HD-FLRDRYERWASHERW.S.LOFT14'-8"6'-4 1/2"BEDRM #321'-0 1/2"W.I.C.CPT.23'-0" 5'-11 1/2"FLEXCLEAR FRAMING11'-1 3/4" INSIDE FRAMING20 AMP.MICRO HOODCIRCUITRANGE2'-4"SINKDW2x6 WALL7'-1"7'-0" CABTS.3'-6" TOP7'-4" TOP3'-5"3'-3"8'-7"2-42'-4"KITVENT HOOD TO OUTSIDEREF.3'-0 5/8"15'-0"1'-6"35'-0"13'-10"7'-2"2x63'-6"3'-6" W/ WOOD CAP 42" HIGH HALF WALL DN 16 R2W 3050 SH9'-8"BATH #2HD-FLR36"5-0 FBGL TUB/SHWR2'-10"TPH TOWEL BAR7'-0"8'-1" 41'-6" 2'-6" 2'-6"11'-1" 41'-6" 30'-0" 16'-9" 11'-6" 7'-3 1/2"5'-11 1/2" 2'-7 3/4"10'-0"35'-0"3'-11 1/2"BEDRM #46'-1 1/2"1'-6"BEDRM #26'-3 1/2"6'-6 1/2" 12'-10"MECH20'-0"AHUMETERRISERAIREXCHGRF.D.UNFIN.WHTANKLESS4-3 SRO 6" FRAMED4'-3"4'-3" 2'-0"7'-3"6'-10"5'-4 1/2"TOWEL RINGBATH #1HD-FLR34x60 FBGLSHWR72"TPHTOWEL BAR12'-0"6'-0"5'-0"5'-0"4'-6 1/2"9'-5"4'-2" CONC PORCH73 SQ. FT.16" WIDE DROPPED SOFFIT(SEE SECTION)DROPPED BEAM3'-10"8"3'-6"3'-6"1'-11 1/2"8"8"TYPICAL PORCH COLUMN:6x6 TREATED POST WITHIN10" SQUARE BOXED COLUMN2'-0"1'-6"2040 SHF.D.22x30ATTICACCESSWATERNOTE:FRAMER TO ROCK , POLY & INSULATEMECH ROOM EXTERIOR WALLS PRIORTO MECH EQUIPMENT BEING INSTALLED3050 SHTEMP3050 SH3050 SH3-0 DR2W 3050 SH14" MFD FLOOR TRUSSESINSTALL PER MFRS SPECS MFD TRUSSES AT 24" O.C. MFD TRUSSES AT 24" O.C.RADONVENT PIPERADONVENT PIPESILLCOCKA/C2-42-42-82-42-42-42-42-42-62-82-82-62-62-64-06068 SGD4'-5"10'-6"1'-5"TEMPW.I.C.CPT.W.I.C.CPT.6'-2 1/2" CLEAR FRAMING3'-10 1/2" 1'-6" 1'-6"7'-0"7'-8"2W 3050 SH2W 3050 SHHD-FLRHD-FLRCPT.FOYERHD-FLR5'-4 1/2"8 1/2"3'-6 3/4"SEWERCLEANOUTCPT.CPT.CPT.CPT.CPT.2x6 2x610"2-62-6WINDOW & DOOR SCHEDULE - MAIN LEVELCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#3-0 DR0.31FOYER0.2311DINING ROOM6068 SGD3050 SHKITCHEN10.3172 1/8" X 80"0.320.310.3136 1/4" X 60 1/4"WINDOW & DOOR SCHEDULE- UPPER LEVELCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#3050 SH1WIC0.3136 1/4" X 60 1/4"0.312W 3050 SH1BEDROOM #10.310.3172 1/8" X 60 1/4"1BEDROOM #30.310.3138 1/4" X 83 1/42W 3050 SH1FLEX RM0.310.3172 1/8" X 60 1/4"1BATH #12040 SH0.3124" X 48"0.313050 SH1STAIRS0.3136 1/4" X 60 1/4"0.313050 SH1BEDROOM #20.3136 1/4" X 60 1/4"0.312W 3050 SH1LIVING ROOM0.310.3172 1/8" X 60 1/4"1BEDROOM #40.310.314'-6"3'-10" 8"9'-0"4'-8"2W 3050 SH72 1/8" X 60 1/4"2W 3050 SH72 1/8" X 60 1/4"OPTIONAL ELEC FIREPLACE3/16"=1'-0"5'-6"1'-4"18-1/4"x44-1/2"S/R1'-6 1/4"RGH OPGALLUSION 48 ELEC FP1'-4"1'-6 1/4" 10" 2X6 WALL 2-2X101/2" PLYWD2X6 FRAMINGINSULATION & 1 LAYEROF ROCK BY FRAMERSMANTLE4'-2"1/2" ROCK OVERROCK RETURNSOF FIREPLACE OPG.+-3'-8 1/2"10 3/4"10 3/4"DRP BEAMSILLCOCK10'-6"WSFUT2x646'-0"OUTLET INSTALLED20AMP DEDICATEDON SIDE WALL OFFIREPLACE OPGDO NOTPOCKETBEAM14" MFD FLOOR TRUSSESINSTALL PER MFRS SPECS16" MFD FLOOR TRUSSESINSTALL PER MFRS SPECS 2" STEP INWALL HEIGHTS2" STEP INWALL HEIGHTSNOTE: INSULATORS TOSPRAY FOAM MECHANICALROOM CEILING AT SAMETIME AS RIM BOARDDO NOT POLYTECH TUBEOUTLET &SET R.O.HEIGHT AT7'-11 3/8"ABOVELANDINGANGLEDWALLON ALL WALLS & CEILINGGYP. BOARDNOTE: PANIC PAN16X36 MECHANICAL SOFFIT4-02'-2 1/4"6'-4 1/4"2'-6"12'-7 3/4"3'-2"1'-10 1/4"14'-6"MUD RMHD-FLRSTOP SHELVINGHEREELEC. FP5'-6"21'-0"2'-0"5'-0"MFD TRUSSES AT 24" O.C.22x30ATTICACCESSTOP OF BEAM FLUSH WITH TRUSSES20'-0" CLEAR FRAMINGGARAGE4" CONC FLOOR581 SQ. FT. (INSIDE)2x6 GARAGE WALLSPOCKETBEAMPOCKETBEAM41'-6"5'-0"HD-FLRPERMIT/CONSTRUCT PLANS4880 171ST STREET WEST LOT 8 BLOCK 6 - BROOKSHIRE IRRIGATIONSYSTEMPLAN OPTIONSLIVING ROOM HD-FLRELECTRIC FIREPLACEIRRIGATION SYSTEM 5FT GARAGE BUMPOUT -Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).3.9555PFHPFH5(2)7-1/4 LSL(2)7-1/4 LSL(2)7-1/4 LSL3-1/2 x 9-1/2 LSL3-1/2 x 9-1/2 LSL(3) 18" LVL3-1/2 x 7-1/4 LSL3-1/2 x 7-1/4 LSL5Shearwall(2) 16" LVL3-1/2 x 7-1/4 LSL3-1/2 x 7-1/4 LSL 1/4"=1'-0"ELECTRICAL PLAN2ND FLOORThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2022C4.0XDRAWN: 3-19-2020X427 HOLCOMBE1ST FLOOR PLAN1/4"=1'-0"GARAGEPORCHPWDRSPRINKLERSYSTEMRECEPTACLELGFIWPSS SS GFIFANBEDRM #4BEDRM #3LS LLLSWPPC#845: 12-15-2020-LLUSBKITCHENA/CSVENT HOOD TO OUTSIDE AIREXCHGRBEDRM #1LW.I.C.BEDRM #2MECHLAU.LGFI LFANGFIBATH #2SD/CMDSD/CMDSDSDSDSDS LLOFTLLLLSLGFI SSSL SSAHUWHF.D.15 AMP CIRCUITFOR POWER VENTW/ SINGLE RECEPTACLEGFILOW VOLTAGESYSTEM RECEPTACLES CDROUGH-INBLANK PLATES LLLLSS FLEXTO LIGHTFIXT ABOVEWPATTICACCESSSWITCH &LIGHT INATTICLSB FRONTREFSS FUTURE WATERSOFT OUTLETF.D.BATH #1S FANSLLIVINGROOM LLLLDWDISP.6'-0"4'-0"4'-0"6'-0"SLLLLL6'-0"3'-3"4'-0"6'-0"PLAN # CHANGE: 3-1-2023-LLRGH-IN INSIDECABINET ONLYAPPLIANCES TO BEON A GFCI OUTLETNOTE: ALL KITCHENW.I.C.SW.I.C.LLS S S LDININGTCHIMESHCPSMART HOMERECEPTACLELLSSD/CMDSSSSSSPRINKLERSYSTEMRECEPTACLE22x30ATTICACCESS FIREPLACEABOVECOUTLET INSTALLED20AMP DEDICATEDON SIDE WALL OFFIREPLACE OPGTUBETECHIRRIGATIONSYSTEMPERMIT/CONSTRUCT PLANS4880 171ST STREET WEST LOT 8 BLOCK 6 - BROOKSHIRE PLAN OPTIONSLIVING ROOM HD-FLRELECTRIC FIREPLACEIRRIGATION SYSTEM 5FT GARAGE BUMPOUT These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2022C5.0XX427 HOLCOMBEPC#1155: 12-29-23-LLPC#1133,1141,1143: 9-14-2023-LLPERMI/CONSTRUCT:4-24-24-AF1/2" SHEATHINGMIN. R-20 INSULATION2x6 STUDS AT 16" O.C.HOUSE WRAPSIDING PER ELEV.BARRIER PASTACOUSTICAL SEALANTEXTEND POLY VAPOR1-1/2" THERMAX2-1/4"X12" DUCTINSULATION(R-10 x 2)1/2"=1'-0"WALL DETAIL4" CONC. GAR. FLOOR5/8" GYP. BD.TYPICAL WALL SECTION (6-16-2015)1/2"=1'-0"9'-1 1/8"VARIESSEE PLANVARIES122x6 STUDS AT 16" O.C.BLOCK AT MIDPOINT2x6 BEARING WALL14x8 CONC. FTG.6" HALF HIGH CONC. CURB. BLK.1/2" ANCHOR BOLTSOMIT BEARING WALLAT STEEL OR LVL BEAMR-49 INSUL.MFD TRUSSESA I R C HU T E S APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGSNOTEDUNLESSOTHERWISENOTEDUNLESSOTHERWISEOVER 1/2" SHEATHINGSHINGLES OVER FELT PAPERRIGID WIND WASH INSTALLED EXTENDINGBARRIER MUST BETO WITHIN 1-1/2" to 2"FROM BOTTOM OFROOF SHEATHING4 MIL. POLY VAPOR / AIR BARRIERALUMINUMCORNICEVENTS40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806TREATED SILL PLATEAPPROVED ANCHORPER CODE (IRC R403.1.6)TREATEDSILL PLATEW/ FOAM SILL SEALMIN. 42" BELOW FINISHED GRADEALL EXTERIOR FOOTINGS TO BE4" INCH CLEAN AGGREGATE ORCONCRETE SLAB AND PREPARED SUBGRADE6 MIL POLY V.B. W/ LAPPED SEAMS 12" BETWEENAPPROVED GAS-PERMEABLE LAYERPASSIVE SUB-SLAB DEPRESSURIZATIONSYSTEM REQUIRED PER MINNESOTARESIDENTIAL ENERGY CODE 1322.2100POURED CONC. WALL(6" CURB, 2" INT. LEDGE)8" THICK, 42" HIGHOPENINGS, JOINTS AND SUMPSFOUNDATION WALL & SLABSEAL JOINT BETWEEN3-1/2" CONC. FLOOR SEALED AT8'-1 1/8"1/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.FLOOR TRUSSES PER PLAN3/4" SUBFLOORSEE PLANVERTICAL CLEARANCE OF NOT LESS THANTHE EXTERIOR WALL TOP PLATETO THE ROOF SHEATHINGSIX INCHES FROM THE OUTSIDE EDGE OF6" MIN. HEEL 6'-0" OF ICE & WATER SHIELDINSTALL PER MFR'S SPECSTERMINATE 12" ABOVE ROOF2x6 SUBFASCIAPROVIDE RECEPTACLE FOR FUTURE RADON FANVENT PIPE SHALL BE INSTALLED WITH A MINIMUM24" HORIZONTAL CLEARANCE AND 36" VERTICALCLEARANCE TO ALLOW FOR FUTURE INSTALLATIONOF RADON FAN (ACTIVE SYSTEM)GYP. BD. W/ VAPOR BARR.1/2" SAG-RESISTANTAPPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGS4 MIL. POLY VAPOR / AIR BARRIERW/ APPROVED SEALANTGYP. BD. W/ VAPOR BARR.1/2" SAG-RESISTANT1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.1/2" GYP. BD.SEAL BEHIND POLY.PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"CONNECTRED TO EACH SIDE OF10' SECTION OF PERFORATED PIPE1/2" OSB or 1/2" TREATED PLYWDAT GROUND LEVEL APPLICANTIONSTO MAINTAIN PERMANENT CONTACTWITH THE UNDERSIDE OFTHE SUBFLOOR DECKINGJOIST CANTILEVER DETAIL(R-30.5) (STC - 41)5" MIN. POLYURETHANE FOAM2x6 EXTERIOR WALLR-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.171/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.R-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.172x6 EXTERIOR WALL3.5" MIN. POLYURETHANE FOAMAT PERIMETER R=20RUNNING THRU UNCONDITIONEDSPACES TO HAVER-4 INSUL. (MIN)VENT PIPER-10 RIGID INSULATIONINTENDED FOR EXTERIOR USEASTM C578, C612 or C1029INSTALLED PER MFR'S SPECSALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTER16x8 CONC. FTG.5000 PSI TESTED -OR-APPROVED ADMIXTUREVERTICAL REINFORCINGAS SOIL COND. REQUIRE(SEE HANSON ENGINEERING)"T" FITTING IN AGGREGATE1/2"=1'-0"GARAGE SLAB LEDGE DETAIL4" 8"1/4"=1'-0"CROSS SECTION D-DFOYER1/4"=1'-0"CROSS SECTION B-B3 1/2" CONC. FLOOR3/4" SUBFLOOR14" MFD FLOOR TRUSSES2'-6"1'-4 1/2"6123'-6"LIVING ROOM9'-1 1/8"GARAGE4" CONC. FLOOR26'-6"15'-6"1/4"=1'-0"CROSS SECTION A-AMFD TRUSS8'-1 1/8"42'-0"3/4" SUBFLOORBEDRM #33'-6"5'-6"7 7/16"16" MFD FLOOR TRUSSES#4BEDRMMECH6123 1/2" CONC. FLOOR3'-6"3/4" SUBFLOOR16" MFD FLOOR TRUSSESFOYERHAND RAIL ALL STAIRSPROVIDE MIN. 6'-8" HEADROOM3) LSL STRINGERS7 3/4" MAX RISE10" TREAD CUTSTAIR DATABEDRM #2LOFT5'-3"25'-7"GARAGE4" CONC. FLOOR21'-0"1/4"=1'-0"CROSS SECTION E-E6121'-0"11" 8'-11 1/8"1/2"=1'-0"OVER UNCONDITIONED SPACEFLOOR DETAILLIVABLE SPACEGARAGER-30 BATT INSULATION3/4" SUBFLOOR6" ROUND DUCTWORKFLOOR TRUSSESR-8 INSULATION WRAP5/8" TYPE 'X' GYP. BD.16"SPRAY FOAM INSUL.AROUND DUCTWORKCLOSED CELL1" CLOSED CELLSPRAY FOAM7 7/16"612COVEREDCONC. STOOPDROPPED BEAM16" WIDEDROPPED SOFFITVERIFY DEPTHPER BEAM SIZE5'-6"1247 1/2"HEEL1'-6"FLEX3 1/2" CONC. FLOOR3/4" SUBFLOOR14" MFD FLOOR TRUSSES7 7/16"6123'-6"#4BEDRM1/4"=1'-0"CROSS SECTION C-C41'-6"41'-6"BEDRM #2WIC35'-0"9'-5"8'-11 1/8"8'-1 1/8"20'-6"GARAGE5'-2 1/16" 4'-4"1'-0"6"5'-10"7'-11 3/8" 13'-9 1/16"14" MFD FLOOR TRUSSES9'-1 1/8"8'-11 1/8"9'-1 1/8"9'-1 1/8"14" FLOOR TRUSSES2" 10'-3 7/8" WALL HEIGHTWALL HEIGHT SPRAY FOAM MECH RMCEILING (MIN. 1-1/2")DO NOT INSTALL POLYNON RHEA HOMES:16" MAX SPAN FORVINYL SOFFIT PANELS.FRAMERS TO ADD NAILINGSTRIPS AS NEEDED. R703.3.1.22X_ LANDING2X10 LND'GSET TOP LANDINGOVER LOWERLANDINGPERMIT/CONSTRUCT PLANS4880 171ST STREET WEST LOT 8 BLOCK 6 - BROOKSHIRE CAUTION: this layout is a mirror image of the original model. Please review all materials for accuracy to ensure bevel cuts, skewed hangers, and other angled output are reported correctly.Customer:Job Name:Plan/Model#:DR HortonX427 Holcombe SOG BAddress //Lot:City, State:, MNJob#:Subdivision:Scale:Prepared By:Lyman Lumber Co.18900 West 78th StreetChanhassen, MN#952-470-4800Sheet: 1 of 3 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Justin H.Checked By:Justin H.Release Date:8-21-23Revision Date:1-26-24Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut Lines Rim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks of Weyerhaeuser NR. © 2014 Weyerhaeuser NR Company. All rights reserved. 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. For A3.1-A3.3 installation specifications see Rim Board Details and Installation in Weyerhaeuser Installation Guide for Floor and Roof Framing, TJ-9001. Plate nail - 16d (0.135" x 312") at 16" on-center* Toe nail - 10d (0.131" x 3") at 6" on-center* When sheathing thickness exceeds 78", trim sheathing tongue at rim board Web Stiffeners required each side at A3._W A3 A3.2A3.1 A3.3 A3W W A3.1 W A3.2 W A3.3 * Floor panel nail - 8d (0.131" x 212") at 6" on-center* 118" TJ® Rim Board, (A3.1/A3.1W only) 114" or 1 12" TimberStrand® LSL. Load bearing or braced/shear wall above (must stack over wall below) Blocking panel: 118" TJ® Rim Board, 114" TimberStrand®LSL or TJI® joist. Web stiffeners required on both sides at B1W and B2W ONLY B1WB1 B2 B2W 116" 2x4 minimum squash blocks Blocking panels may be required with braced/shear walls above or below — see detail B1 TJI® 560 floor joist Top View NAILING AT BEARING (FLOOR) 134" minimum end bearing single-family applications TJI® Joist to Bearing Plate 118" TJ® Rim Board, 114" or 1 12" TimberStrand® LSL. or TJI® 110 rim joist: One 10d (0.131" x 3") nail into each flange TJI® 210, 230, and 360 rim joist: One 16d (0.135" x 312") nail into each flange. With depths > 16", use TJI® 360 rim joist. Shear transfer: Connections equivalent to floor panel nailing schedule TJI® 560 rim joist: Toe nail with 10d (0.128" x 3") nails, one each side of TJI® joist flange Rim to TJI® Joist Squash Blocks to TJI® Joist (Load bearing wall above) One 10d (0.128" x 3") nail into each flange 118" TJ® Rim Board or 114" or 1 12" TimberStrand® LSL. Also see detail B2 Locate rim board joint between joists. 134" minimum bearing One 8d (0.113" x 212") nail each side. Drive nails at an angle at least 112" from end. 312" minimum intermediate bearing 514" may be required for maximum capacity Use 2x4 minimum squash blocks to transfer load around TJI® joist CS Load from above 2x4 minimum squash blocks 116" Blocking panel: 118" TJ® Rim Board, 114"or 112" TimberStrand® LSL, or TJI® joist End of joists at centerline of support B4 Load bearing or braced/shear wall above (must stack over wall below when present) B4W Web stiffeners required on both sides of both joist ends at B4W ONLY Hanger Backer Block: Install tight to top flange (tight to bottom flange with face mount hangers). Attach per the table below. Clinch nails when possible. H2 Backer block both sides of web with single TJI® joist Double TJI® Joist Filler Block: Attach per the table below. Clinch nails when possible. With top mount hangers, backer block required only for downward loads exceeding 250 (395 factored) lbs or for uplift conditions. For filler and backer block sizes see Weyerhaeuser Installation Guide for Floor and Roof Framing, TJ-9001. TJI® Depth, D TJI® Flange Width Block Type Nail Size Quantity 912" <D< 20" 20" <D< 24" less than 312" 312" 312"Filler Backer 16d(0.135" x 312") 10d(0.128" x 3") 25 - each side 15 Filler Backer 16d(0.135" x 312") 10d(0.128" x 3") 15 - each side 15 Filler Backer 10d(0.128" x 3") 15 1510d(0.128" x 3") For nailing capacities refer to TB-834 (ASD) and TB-861 (LSD) For triple TJI® joist header conditions refer to Weyerhaeuser Technical Bulletin TB-820 WARNING Joists are unstable until braced laterally. Safety bracing required during installation. rim board closure 1 1/8" iLevel along panel edges and in field Additional connections may be required to transfer lateral loads from wall above. Attach with 8d (2 1/2" box) nails @ 6" o.c. 24/16 span rated sheathing (7/16" min.) iLevel rim board or 2X8 (min)solid sawn nailed to top plate Maximum 1 1/8"x4 1/2" (min.) 8d (2 1/2" box) nails @ 6"o.c. 2x plate -Joist must be sized properly for vertical loading (Block must be full length between joist (Verify with building official if pressure treated plywood is required due to distance from ground) Lateral load transfer due to wind or seismic loads for this detail is 180 PLF (pound per linear foot) meeting conventional construction building practices TJI® Joist and tight to each flange) -See details in iLevel specifiers guide for all other requirements EXTERIOR DECK ATTACHMENT Structural exterior sheathing See fastener table below. Maintain 2" distance (minimum) from edge of ledger to fastener. LA Flashing Treated 2x_ ledger 118" TJ® Rim Board or 114" or 112" TimberStrand®LSL. (1) Corrosion-resistant fasteners required for wet-service applications. (2) Allowable load determined in accordance with ASTM D7672. (3) 118" TJ® Rim Board is allowed with joist depths < 16" only. (4) Maximum 12" shimmed air space. Fastener Allowable Load (lbs/bolt) 480 12" lag bolt 118" TJ® Rim Board Rim Board Material 1 14" TimberStrand® LSL 1 12" TimberStrand® LSL 610 675 695 12" Through bolt 725 725 12" Through bolt with Air Space 615 (2) (3) (4) _ W Web stiffener both sides. See table below. 2x4 Minimum Web Stiffener Size 58" x 2516" 34" x 2516" 78" x 2516" 560 Tight fit* 110 210 230 & 360 End 3 WEB STIFFENER ATTACHMENTGap*: 18" minimum 234" maximum TJI® Joist Series Type 8d (0.113" x 212") 1" (112" for TJI® 560, 560D) * With point load from above, and no support below, install web stiffener tight to top flange (gap at bottom flange) All Depth (in.) 560D All All All 18" 20" 22" 24" 2x4 Nailing Requirements 16d (0.135" x 312") 16d (0.135" x 312") 3 Number Nails Intermediate 4 5 6 6 4 5 11 13 (2) (2) (1) (1) (1) Nailing: See table below. (1) PS1 or PS2 sheathing, face grain vertical (2) Construction grade or better (3) Web stiffeners are always required for 22" and 24" TJI® 560D Joists (3) (3) Floor panel nail - 8d (0.131" x 212") at 6" on-center Toe nail - 10d (0.131" x 3") at 6" on-center Install proper blocking to support all panel edges Sheathing boundry nails, 8d (0.131 x 212") at 4" o.c. For additional installation specifications see Rim Board Details and Installation in Weyerhaeuser Installation Guide for Floor and Roof Framing, TJ-9001. A3.4 12" min. 2x_ stud wall at 16" on-center Plate nail, 16d (0.135" x 312") at 12" on-center When sheathing thickness exceeds 78", trim sheathing tongue at rim board A3.4 W Web stiffeners required on both sides at A3.4W ONLY For rim board thicker than 134" - Attach TJI Joist to rim board with one 10d (0.128" x 3") nail. Top nail from TJI joists into rim board. - Connect corner with four 10d (0.128" x 3") nails. Toe nail from side of parallel closure into rim board. 114" or 1 12" TimberStrand®LSL rim board. 8" diameter maximum hole for 1178" - 16" deep blocking panels; 6" diameter maximum for blocking panels 912" deep or shorter than 12" long. Do not cut flanges. Attach reinforcement to joist flange with 8d (0.131" x 212") nails at 6" on-center. When reinforcing both sides, stagger nails. E3E2 2 '-0 "m a x im u m Face grain horizontal 4'-0" length of 34" reinforcement on one side at E2, both sides at E3 118" TJ® Rim Board or 114" or 112" TimberStrand® LSL. Nail with 10d (0.131" x 3") nails, one each at top and bottom flange. 2 '-0 " m a x im u m Not for use with 312" TJI® joist flange widthsE4 Attach reinforcement to joist web with 3 rows 10d (0.148" x 3") nails at 6" on-center, clinched. Use 2 rows with 912" and 1178" TJI® joists. 8" diameter maximum hole for 1178" - 16" deep blocking panels; 6" diameter maximum for blocking panels 912" deep or shorter than 12" long. Do not cut flanges. 6'-0" length of TJI® joist reinforcement and filler block. Use 4'-0" length with 912" and 1178" TJI® joists. 118" TJ® Rim Board 114" or 112" TimberStrand® LSL. Nail with 10d (0.131" x 3") nails,one each at top and bottom flange. Top mount hanger H1 Face mount hanger Web stiffeners required if sides of hanger do not laterally support at least 38" of TJI® joist top flange Hanger height must be a minimum of 60% of joist depth L6 Multiple pieces can be nailed or bolted together to form a header or beam of the required size, up to a maximum width of 7" Load must be applied evenly across entire beam width. Otherwise, use connections for side-loaded beams. When fasteners are required on both sides, stagger fasteners on the second side so they fall halfway between fasteners on the first side. (1) 10d nails are 0.128" diameter; 12d-16d nails are 0.148" - 0.162" diameter; screws are SDS, SDW, USP WS, or TrussLOK® (2) An additional row of nails is required with depths of 14" or greater. (3) When connecting 4-ply members, nail each ply to the other and offset nail rows by 2" from the rows in the ply below. Piece Width # of Plies Fastener Type Min. Length # Rows O.C. Spacing Location 10d nails 3" 312" 134" 2 3 4 2 12d-16d nails Screws 10d nails 12d-16d nails Screws 10d nails 12d-16d nails Screws Screws 12" bolts (1) (3) (3) 3 14" 338" or 312" 3" 3 14" 338" or 312" 5" 3" 3 14" 5" or 6" 6 34" 5" or 6" 6 34" 8" 3 2 2 3 2 2 3 2 2 2 2 12" 24" 12" 24" 12" 24" 24" 24" One side Both sides One side Both sides One side(per ply) Both sides One side Both sides One side - (2) (2) (2) (2) (2) (2) Fastener Installation Requirements Multiple-Member Connections for Top-Loaded Beams Option #2: 2x_ strapping installed at 13 joist-span locations using two 212" screws per joist, typical Option #1: TJI® joist blocking with end blocks installed at 13 joist-span locations using two 8d (0.113" x 212") nails or 212" screws, typical PB1 Option #3: Directly applied ceiling When specified on the layout, one of the bracing options above is required Apply subfloor adhesive to all contact surfaces 8 ' m a x .1 3 jo is t s p a n DO NOT cut, notch or drill holes in headers or beams except as indicated in illustrations and tables. DO NOT cut or notch flange. DO NOT cut holes in cantilever reinforcement. 112" hole may be cut anywhere in web out- side of hatched zone Min. distance from Table ANo field cut holes in hatched zones Minimum distance from edge of hole to inside face of nearest end support minimum (applies to all holes except knockouts) Table A - End Support 6" 6"1L 12 x D 1D DL 2 x L minimum 2 2 6" 6" 2 ALLOWABLE HOLES - TJI® Joists 1.3E TimberStrand®LSL allowed hole zone dd Microllam®LVL and Parallam® PSL allowed hole zone middle 13 span 1.3E TimberStrand® LSL hole zone Microllam®LVL and Parallam® PSL hole zone 2 x diameter of the largest hole (minimum) d 13 depth 1" 2" 134" Maximum Round Hole Size Header or Beam Depth 438" 714"- 20" 512" See illustration for Allowed Hole Zone Other Trus Joist® Headers and Beams 1.55E TimberStrand®LSL Headers and Beams ALLOWABLE HOLES - Headers and Beams 13 depth 2 x diameter of the largest hole (minimum) 8" See illustration for allowed hole zone 1114"-11 78" 14"-16" 914"-912" 358" 458" 3" No holes in headers or beams in plank orientation. Round holes only General Notes General Notes No holes in headers or beams in plank orientation. Allowed hole zone suitable for headers and beams with uniform loads only. Round holes only No holes in cantilevers. Allowed hole zone suitable for headers and beams with uniform and/or concentrated loads. Maximum Round Hole Size Header or Beam Depth 8" Allowed hole zone Min. distance from Table BDo not cut holes larger than 112" in cantilever 6"Closely grouped round holes are permitted if the group perimeter meets requirements for round or square holes. 10'-0" 11'-6"3'-0"1'-0"1'-0" 1'-6" 9'-0"9'-0"6'-6"4'-6"1'-0" 1'-0"1'-0"360 1'-0" 12'-0" 17" 13" 15'-6" 15'-6" SQUARE OR RECTANGULAR HOLE SIZE Minimum distance from edge of hole to inside face of nearest intermediate or cantilever support 16'-6" 16'-0" 21'-0" 20'-6" 18'-0" 17" 17'-0" For simple span (5' minimum), uniformly loaded joists used in residential applications, one maximum size round hole may be located at the center of the joist span provided that no other holes occur in the joist. Distances are based on the maximum uniform loads from current Trus Joist specifier's guides. For other load conditions or hole configurations use Forte® software or contact your Weyerhaeuser representative. 15"8" 10"6"4"12"17"15"12"10"8"6"4" 16'-0" 15'-6" Holes may be located vertically anywhere within the web. Leave 18" of web (minimum) at top and bottom of hole. Knockouts are located in web at approximately 12" on-center; they do not affect hole placement. 1'-0" 1'-0" 1'-0" 1'-0" Rectangular holes based on measurement of longest side. 18" 20"1'-0"560 560 360 360 1'-0" 1'-0" 1'-0" 1'-0" 1'-6" 1'-0" 2'-0" 3'-0" 3'-0" 6'-0" 6'-0" 12'-0"5'-6" 16'-6" 11'-0" 15'-0" 10'-0" 6'-0" 9'-0" 6'-0" 3'-0" 1'-6" 4'-0" 1'-0" 1'-0" 1'-0" 1'-0" 16'-6" 18'-0" 16'-6" 14'-0"8'-6" 7'-0" 9'-0" 11'-6" 16'-6" 12'-6" 14'-6" 19'-6"17'-6' 19'-0" 20'-0" 19'-6" 10'-0" 17" 11'-0" 13" 10'-6" ROUND HOLE SIZE Table B - Intermediate or Cantilever Support 11'-0" 10'-0" 15'-0" 13'-6" 4'-0" 8'-6"2'-6"230 3'-0" 1'-0" 1'-0" 1'-0" 1'-0" 3'-0" 3'-0" 1'-0" 1'-0" 4'-0" 1'-0" 2'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 16" 14" 230 560 360 1'-0" 1'-0" 1'-0" 230 560 210 360 1'-0" 1'-0" 1'-0" 1'-0" 1178"1'-0"230 360 110 210 560 2'-0" 1'-0" 1'-6" 360 210 110 3'-0" 1'-0" 1'-0" 9'-6"5'-6"1'-0" 2'-6" 1'-0" 1'-0" 1'-0" 1'-6" 2'-6" 3'-0" 1'-0" 1'-0" 1'-6" 2'-0" 1'-0" 5'-6" 5'-6" 3'-6" 11'-0" 10'-0" 4'-0" 7'-0" 6'-6" 6'-6" 10'-6" 13'-6" 12'-6" 6'-0" 9'-6" 3'-6" 8'-6" 6'-0" 2'-6" 5'-0" 4'-0" 1'-0" 4'-6" 7'-0" 2'-0" 8'-0" 5'-6" 2'-0" 1'-6" 4'-6" 4'-0" 9'-0" 10'-0" 11'-0" 4'-6" 12'-0" 8'-6" 9'-0" 8'-6" 6" 3" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 2'-6" 2'-6" 912" TJI® 210 110 2" 2'-0" 2'-0" 18" 20" 1'-0"360 560 560 360 1'-0" 1'-0" 1'-0" 560 1'-0" 4" 4" 3'-6" 3'-6" 612" 8'-0" 7'-6" 878" 11" 1'-0" 2'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 8"10" 1'-0" 10'-0"5'-0" 11'-0"5'-0" 1'-0" 2'-0" 7'-0" 7'-0" 5'-0" 12" 7'-6" 15" 7'-6"3'-6"2'-0" 4'-6" 4'-6" 2'-0" 1'-6" 3'-6" 2'-6" 1'-0" 1'-0" 1'-0" 3'-0" 1'-0" 1'-0" 2'-0" 4'-6" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 2'-0" 1'-0" 3'-0" 3'-0" 1'-0" 1'-0" 13'-0"6'-0"2'-0" 10'-0" 10'-6" 13'-6" 12'-0" 11'-0" 14'-6" 13'-0" 1'-0" 3'-6" 2'-0" 5'-0" 9'-0" 7'-6" 1'-0" 5'-0" 4'-0" 2'-6" 6'-6" 4'-6" 10'-0" 9'-0" 13'-6" 16'-0" 14'-6" 13'-6" 12'-6" 15'-0" 14'-0" 10'-0" 12'-0" 11'-0" 10'-6" 10'-0" 8'-6"3'-6" 5'-0" 1'-0" 6'-0" 9'-6" 5'-0" 10'-6" 5'-6" 3'-0" 2'-6" 8'-0" 8'-0" 7'-0" 12'-0"9'-0" 9'-6" 2'-0" 6" 1'-6" 1'-0" 1'-0" 3" 1'-0" 3'-0" 2'-6" 2'-0" 1'-6" 2" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 4" 4'-0" 3'-6" 4"612" 7'-6" 6'-6" 11"878" 10'-0" 12'-0" 11'-6" 11'-0"10'-0"5'-0" 6'-6" 4'-0" 2'-6" 11'-0" 9'-6" 8'-0" 3'-0" 8" 4'-6" 10" 13'-6" 14'-6" 14'-6" 14'-0" 12'-6' 11'-0" 15"12" 13" 11'-0" 11'-0" SQUARE OR RECTANGULAR HOLE SIZE 13" 6'-0" 7'-0" ROUND HOLE SIZE 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-6" 2'-0" 2'-0" 1'-6" 1'-6" 1'-0" 1'-6" 1'-0" 2'-0" 2'-6"1'-6"560 16" 14" 1'-0"360 210 230 560 1'-0" 1'-0" 1'-0" 210 230 110 1'-0" 1'-0" 1'-0" 1178" 912" 110 230 360 210 1'-0" 1'-0" 1'-6" 1'-0" 110 230 360 210 1'-0" 1'-6" 1'-6" 1'-0" 8'-0"3'-0" 4'-0" 1'-6" 1'-0" 1'-0" 2'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-6" 8'-0"5'-6" 2'-6" 3'-0" 6'-6" 3'-6" 4'-0" 9'-0" 3'-6" 4'-0" 3'-0" 6'-0" 7'-0" 5'-6" 1'-6" 2'-0" 3'-0" 2'-0" 2'-0" 3'-6" 2'-6" 2'-0" 2'-0" 2'-6" 3'-0" 2'-6" 4'-0" 3'-6" 3'-0" 3'-0" 5'-6" 6'-6" 7'-0" 6'-0" 3" JOIST DEPTH TJI® 2" 4" 8 78" 11" 1'-6" 2'-0" 1'-6" 2'-6" 2'-0" 2'-0" 3'-6" 2'-6" 1'-0" 1'-6" 1'-0" 1'-0" 1'-6" 1'-0" 1'-0" 3'-0" 2'-6" 1'-0" 1'-0" 1'-0" 1'-6" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-6" 1'-0" 1'-0" 1'-0" 1'-6" 1'-0" 5'-6"4'-6" 8'-0" 4'-0"2'-6" 1'-0" 1'-0" 4'-0" 2'-0" 2'-0" 5'-0" 2'-0" 1'-6" 2'-0" 3'-0" 2'-6" 2'-0" 9'-6"8'-0" 9'-0" 8'-0" 10'-0" 7'-0" 6'-6" 9'-0" 9'-0" 8'-6" 8'-0" 7'-0" 6'-0" 6'-6" 2'-0" 3'-6" 2'-6" 2'-6" 2'-6" 4'-6" 3'-6" 3'-0" 3'-6" 3'-0" 2'-6" 2'-6" 3'-6" 5'-0" 4'-6" 4'-0" 7'-6" 7'-0" 6'-6" 6'-0" 3"2" 4" 11"878"612" 5'-6" 5'-0" 5'-6" 6'-0" 3'-0" 3'-0" 4'-6" 2'-6" 2'-0" 2'-6" 1'-6" 4'-6" 1'-0" 1'-6" 3'-6" 5'-6" 2'-6" 2'-6" 612" 4'-6" 5'-0" 5'-0" 5'-6" 5'-0" 5'-6" 6'-6" 4'-6" 3'-6" 4'-0" 4'-0" 7'-0" 3'-6" 3'-0" 6'-0" 7'-0" 6'-6" 5'-0" 3'-6" 3'-6" 5'-0" 3'-0" 2'-6" 2'-6" 2'-0" 5'-0" 1'-6" 1'-6" 4'-0" 6'-0" 3'-0" 2'-6" 5'-6" 5'-6" 6'-6" 5'-0" 4'-0" 4'-6" 5'-0" 7'-6" 4'-0" 3'-6" 6'-6" 7'-6" 7'-0" 5'-6" 5"5"7"7" 1'-6" 2'-6" 3'-0" 5" 4'-6" 5'-0" 2'-6" 3'-0" 6'-6" 5'-6" 1'-0" 5'-6" 3'-6" 3'-6" 3'-6" 1'-0" 2'-0" 1'-0" 1'-0" 1'-0" 1'-0" 5'-6" 7" 4'-6" 3'-0" 2'-0" 3'-6" 4'-0" 4'-0" 1'-0" 6'-6" 6'-0" 5'-6" 7'-6" 2'-6" 8'-6" 5'-0" 7"5" 5'-6" 6'-6" 3'-6" 2'-6" 5'-6" 4'-0" 4'-0" 1'-6" 7'-0" 5'-6" 5'-0" 7'-0" 2'-6" 8'-0" 7'-6" 4'-6" 4'-0" 6'-6" 8'-0" 11'-0" 6'-0" 9'-6" 9'-0" 10'-0" 11'-0" 5'-6" 7'-6" 8'-6" 10'-0" 6'-0" 7'-0" 7'-0" 5" 1'-0" 1'-0" 1'-0" 1'-0" 7" 1'-0" 1'-0" 1'-0" 1'-0" 5" 7" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 3'-0" 4'-0" 5" 1'-0" 1'-0" 1'-0" 1'-0" 1'-6" 1'-0" 1'-0" 1'-0" 7"5" 1'-0" 1'-0" 3'-6" 1'-6" 6'-6" 4'-0" 6'-0" 8'-6" 7" JOIST DEPTH FILLER and BACKER BLOCK SIZES (1) If necessary, increase filler and backer block height for face mount hangers and maintain 18" gap at top of joist; see detail W. Filler andbacker block dimensions should accomodate required nailing without splitting (12" minimum for backer blocks and 24" minimum for filler blocks). 2x10 6'-0" long 110TJI® Joists Cantilever Filler (Detail E4) Filler Block (1) (Detail H2) Backer Block (1) (Detail F1 or H2) 2x6 4'-0" long 58" or 34" Depth 2x6 2x8 912" or 1178"14" 210 230 or 360 560 1178" Two 2x6 2x6 2x6 + 12" sheathing 4'-0" long 912" or 1178" 2x6 + 12" sheathing 2x6 + 38" sheathing 4'-0" long 2x10 + 38" sheathing 6'-0" long 34" or 78" 2x8 + 38" sheathing 2x6 + 38" sheathing 912" or 1178" 14" or 16" 2x10 + 12" sheathing 6'-0" long 78" or 1" Net 2x8 + 12" sheathing 14" or 16" 2x12 + 12" sheathing Not applicable 18" or 20" 2x122x8 18" or 20" Two 2x12 Not applicable Two 2x8 14" or 16" 1.5E TimberStrand®LSL Prescriptive Chart 13 depth 2 x diameter of the largest hole (minimum) 8" See illustration for allowed hole zone 1114"-11 78" 14"-16" 914"-912" 358" 458" 3" Round holes only General Notes No holes within 8" of joist ends. Maximum Round Hole SizeJoist Depth Allowed hole zone 1.5 E TimberStrand® LSL 8" Round holes larger than 3-5/8" up to 7-1/4" max. in 1.5" x 11-7/8" 1.5E TimberStrand LSL joist only Edge of large holes need to be at least 4 times the diameter of the largest hole (for a 7-1/4" hole, the closest distance allowed to the next hole is 29", even if the next hole is a small 12" diameter hole). The hole must be centered within the joist vertically. No square or rectangular holes No more than (2) holes between 3-5/8" and 7-1/4" diameter allowed per span. See chart below for minimum distance from inside face of bearing to edge of hole for holes larger than 3-5/8" but not greater than 7.25" Minimum distance from edge of hole to inside face of bearing (end or intermediate) 4"5"6.5" 7.25" 2'-0"2'-0" 3'-0"3'-6" the area of a 7-1/4" circumscribed hole A smaller hole can be drilled within centered in the depth of the joist circumscribed 7-1/4" hole smaller hole drilled within circumscribed area of 7-1/4" hole assuming the circumscribed hole is a minimum of 3'-6" from face of bearing 1-1/2" x 11-7/8" 1.5E TimberStrand LSL floor joist No load bearing wall above Web stiffeners required each side at B3W ONLY B3WB3 Blocking panels may be required with braced/shear walls above or below — see detail B1 8" diameter maximum hole for 117 8" - 16" deep blocking panels; 6" diameter maximum for blocking panels 912" deep or shorter than 12" long. Do not cut flanges. E1 E1W Web stiffeners required on both sides at E1W ONLY 118" TJ® Rim Board or 114" or 112" TimberStrand® LSL. Nail with 10d (0.131" x 3") nails, one each at top and bottom flange.SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ONTHIS DRAWING. LYMAN COMPANIES WOULD ONLY BE RESPONSIBLE FOR THEINDIVIDUAL MEMBER DESIGN, BASED UPON THE ASSUMED OR KNOWN VERTICALLOADS. THE BUILDER OR GENERAL CONTRACTOR IS RESPONSIBLE FOR THESTRUCURE(S) OVERALL DESIGN, AND IT IS STRONLY RECOMMENDED THAT ALLDRAWINGS AND CALCULATIONS BE REVIEWED BY THE ENGINEER OF RECORD FORTHE PARTICULAR PROJECT. Framing Connector Summary PlotID Qty Manuf Product Design Method Face Nails Member Nails Backer Blks Filler Web Stiff H1 1 Simpson HHUS48 Designed 22- 10d 8- 10d No No No Products PlotID Length Product Plies Net Qty B1 22' 0" 1 3/4" x 18" 2.0E Microllam LVL 3 3 Pt1 8' 0" 5 1/4" x 5 1/4" 1.8E Parallam PSL 1 2 B3 16' 0" 3 1/2" x 7 1/4" 1.3E TimberStrand LSL 1 1 B5 6' 0" 3 1/2" x 7 1/4" 1.3E TimberStrand LSL 1 1 B7 6' 0" 2 x 10 SPF No.1/No.2 2 2 Wall Framing PlotID Length Product Plies Net Qty B2 8' 0" 3 1/2" x 9 1/2" 1.55E TimberStrand LSL 1 2 B4 8' 0" 3 1/2" x 7 1/4" 1.3E TimberStrand LSL 1 1 B6 4' 0" 3 1/2" x 7 1/4" 1.3E TimberStrand LSL 1 1 B8 4' 0" 2 x 10 SPF No.1/No.2 2 4 5'-0" Bumpout Option Add List PlotID Length Product Plies Net Qty B9 22' 0" 1 3/4" x 16" 2.0E Microllam LVL 2 2 3rd Stall Garage Option Add List PlotID Length Product Plies Net Qty B9 22' 0" 1 3/4" x 16" 2.0E Microllam LVL 2 2 B10 10' 0" 3 1/2" x 9 1/2" 1.55E TimberStrand LSL 1 1 B8B2B2 B8B6 B4B1 B3B7B5B9B9B10 Pt1Pt1 H1 2 Trimmers Each End PSL Trimmers at both ends 16" Floor Truss 14" Floor Truss 14" Floor Truss 2-2x62-2x6 5'-0" Bumpout Option3rd Stall Garage Option D.R. Horton and Energy Star Requirements: -4 stud U corners required for siding and sheetrock backing. -Full depth headers as marked required for load transfer. -Double jack studs as marked under full depth headers required for load transfer. -Cripple studs required for load transfer at both ends of window sill and required for drywall on center spacing. Dropped beam CAUTION: this layout is a mirror image of the original model. Please review all materials for accuracy to ensure bevel cuts, skewed hangers, and other angled output are reported correctly.Customer:Job Name:Plan/Model#:DR HortonX427 Holcombe SOG BAddress //Lot:City, State:, MNJob#:Subdivision:Scale:Prepared By:Lyman Lumber Co.18900 West 78th StreetChanhassen, MN#952-470-4800Sheet: 2 of 3 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Justin H.Checked By:Justin H.Release Date:8-21-23Revision Date:1-26-24SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ONTHIS DRAWING. LYMAN COMPANIES WOULD ONLY BE RESPONSIBLE FOR THEINDIVIDUAL MEMBER DESIGN, BASED UPON THE ASSUMED OR KNOWN VERTICALLOADS. THE BUILDER OR GENERAL CONTRACTOR IS RESPONSIBLE FOR THESTRUCURE(S) OVERALL DESIGN, AND IT IS STRONLY RECOMMENDED THAT ALLDRAWINGS AND CALCULATIONS BE REVIEWED BY THE ENGINEER OF RECORD FORTHE PARTICULAR PROJECT. Wall Framing PlotID Length Product Plies Net Qty B1 8' 0" 1 3/4" x 7 1/4" 1.55E TimberStrand LSL 2 6 B2 4' 0" 2 x 10 SPF No.1/No.2 2 8 B1 B1B1 B2B2B2 B2Roof Trusses Roof Trusses Canted 1'-6" here. 2 Trimmers Each End D.R. Horton and Energy Star Requirements: -4 stud U corners required for siding and sheetrock backing. -Full depth headers as marked required for load transfer. -Double jack studs as marked under full depth headers required for load transfer. -Cripple studs required for load transfer at both ends of window sill and required for drywall on center spacing. CAUTION: this layout is a mirror image of the original model. Please review all materials for accuracy to ensure bevel cuts, skewed hangers, and other angled output are reported correctly.Customer:Job Name:Plan/Model#:DR HortonX427 Holcombe SOG BAddress //Lot:City, State:, MNJob#:Subdivision:Scale:Prepared By:Lyman Lumber Co.18900 West 78th StreetChanhassen, MN#952-470-4800Sheet: 3 of 3 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Justin H.Checked By:Justin H.Release Date:8-21-23Revision Date:1-26-24SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ONTHIS DRAWING. LYMAN COMPANIES WOULD ONLY BE RESPONSIBLE FOR THEINDIVIDUAL MEMBER DESIGN, BASED UPON THE ASSUMED OR KNOWN VERTICALLOADS. THE BUILDER OR GENERAL CONTRACTOR IS RESPONSIBLE FOR THESTRUCURE(S) OVERALL DESIGN, AND IT IS STRONLY RECOMMENDED THAT ALLDRAWINGS AND CALCULATIONS BE REVIEWED BY THE ENGINEER OF RECORD FORTHE PARTICULAR PROJECT. COPYRIGHT HANSON GROUP, LLC 2022©MATERIALSWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLSL:134" WIDTH - 1.55E OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLOADSROOF SNOW LOAD: 35-42 PSFROOF DEAD LOAD: 15 PSFFLOOR LIVE LOAD: 40 PSFFLOOR DEAD LOAD: 15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODE2020 MINNESOTA RESIDENTIAL CODEHARDWAREALTERNATETABLESIMPSONPRODUCTUSPPRODUCTA34MP34A35MPA1H2.5RT7HTT5HTT45LSTASTRAPSAMELTP4MP4FMSTCSTRAPSAMESTHD14/RJSTAD14/RJTITEN HDWEDGEBOLTHARDWARE IN SAMEROW MAY BE USEDINTERCHANGEABLYIN THIS DOCUMENTDescriptionDecember 15, 2022Project Number:Date:2.592S11Sheets: of1D R Horton 20860 Kenbridge Court #100Lakeville, MN 55044X407/X427B-GL ModelMinnesota Construction3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.DateRevisionPrint Name:Signed: License Number:Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.SCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM FOR A SINGLE-FAMILY RESIDENCE. CONSTRUCTION ISTO BE IN ACCORDANCE WITH THIS DOCUMENT, STANDARD INDUSTRY PRACTICE, AND THE CODE.NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO CONSTRUCTION DOCUMENTS FOR MORE INFORMATION.2.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICHMEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x6 STUDS SPACED @ 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.3.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. ORTYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)4.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS.5.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIP OR EQUIVALENT AND (4) 0.131"Ø x 3"TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.6.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12) 0.131"Ø x 3" INLAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3" FACE NAILS.7.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).8.TALL WOOD WALL FRAMING IS TO BE DESIGNED BY SUPPLIER FOR GRAVITY AND OUT-OF-PLANE WIND LOADS.9.THE ENTRY PORCH IS CONSIDERED TO BE A PRIMARILY OPEN, NON-ESSENTIAL PORTION OF THE STRUCTURE AND ISEXCLUDED FROM THE OVERALL MAIN WINDFORCE SYSTEM OF THE HOME. PROVIDE CODE REQUIRED UPLIFTCONNECTIONS AT ALL POSTS.THIS SHEET/S REPRESENTS A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRERESIDENTIAL STRUCTURE. THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WINDRESISTING ELEMENT THAT IS REQUIRED FOR THE HANSON GROUP'S DESIGN IS SHOWN ON THE STRUCTURALDRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TOROOF TRUSSES ABOVE, TO JOISTS/TRUSSES/BLOCKING ABOVE, AND TOJOISTS/TRUSSES/BLOCKING BELOW. THESE PANELS ARE NOT NECESSARILYREQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR JOISTS)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.EXTERIOR NON-BEARING WALLFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUMSHEATHING BOTH FACES WITH EITHER FASTENER OPTIONLISTED IN NOTE 3, SPACED AT 4" O.C. PROVIDE INCREASEDFASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TOBE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)INDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ONEXTERIOR FACE IN ACCORDANCE w/ NOTE 2. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.(MIN. LENGTH)w/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIPNAIL BOTTOM PLATETO RIM/JOIST/BLOCKING w/ (3) 16dNAILS EVERY 16"NAIL BOTTOM PLATETO RIBBON BRACE /TRUSS w/ (3) 16dNAILS EVERY 16"NAIL EACH JOIST TOTOP PLATES w/ (3)0.131"Ø x 3" NAILS2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHNAIL EACH TRUSS TOTOP PLATES w/ (3)0.131"Ø x 3" TOENAILSROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"NAIL RIM TOPPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO LADDERTRUSS w/ (3) 16dNAILS EVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/0.131"Ø x 3"NAILS @ 6" O.C.INTERIOR WALLPERPENDICULAR TO FRAMINGINTERIOR WALLPARALLEL w/ FRAMING2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN JOISTSNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH JOIST TO TOPPLATE w/ (3) 0.131"Ø x 3" NAILSNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN TRUSSESNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH TRUSS TO TOP PLATEw/ (3) 0.131"Ø x 3" TOENAILSPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE JOIST DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSS DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATE w/(3) 16d NAILS EVERY 16"(OR AS SHOWN TOTHE RIGHT IF REQ'D)FASTEN PLATE w/ 14"CONCRETE SCREWS ORPOWDER ACTUATED 0.145"WASHERED PINS @ 16" O.C.w/ 1" EMBEDMENT INCONCRETEGarrett Brunell12-15-2252600PARTIAL LOWER LEVEL HOUSE PLANSHOWN FOR LOCATION REFERENCE ONLY1S1REFERENCE PLANTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO WALKOUT FOUNDATIONSTHE REQUIREMENTS SHOWN DIRECTLY ABOVE ONLY APPLY TO LOOKOUT FOUNDATIONSMAIN LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY2S1REFERENCE PLANUPPER LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY3S1REFERENCE PLANWITH GARAGE SIDE 5FT BUMP-OUT OPTIONWITH 3RD STALL GARAGE OPTIONPOST-INSTALLED HOLDOWN OPTION6S1FRAMING DETAIL12"Ø SIMPSONTITEN HD RODCOUPLER w/8" EMBED INTOCONCRETE12"ØTHREADEDROD w/ NUT &WASHER ATHOLDOWNENDSIMPSON HTT5HOLDOWNANCHOR NAILEDTO DOUBLE STUDSFLOORSYSTEMCONCRETEFOUNDATIONBELOWALTERNATE HOLDOWNALTERNATE RAISED HOLDOWNCONCRETEFOUNDATIONBELOWSIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWN w/12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHORPROVIDE 14" x 4" CONCRETESCREWS @ 32" O.C. THRU SILLPLATE INTO FOUNDATION ATTHIS WALL PORTION INADDITION TO ANCHOR BOLTSSIMPSON STHD14RJEMBEDDED HOLDOWNANCHOR AT LOCATIONSSHOWN (REFER TO 6/S1FOR ALTERNATIVE OPTION)PROVIDE DOUBLE STUDSAT EACH END OFSHEARWALL (MAY USEBEARING/KING STUDS ASREQ'D)HEADER & BEARING/KINGSTUDS AT SIDES OFOPENINGS BY OTHERSHATCHED AREA INDICATES716" OR THICKERPLYWOOD/OSB EXTERIORSHEATHING FASTENED TOSTUDS w/ 8d NAILS @ 4" O.C.AT PANEL EDGES & @ 12"O.C. AT INTERIOR SUPPORTSTYPICAL 2x6 STUDS @ 16" O.C.FASTEN BOTTOM PLATEw/ (3) 16d NAILS EVERY 16"PERFORATED SHEARWALL RAISEDABOVE FLOOR SYSTEM5S1FRAMING DETAILFASTEN FRAMING ABOVEAS SHOWN FOR BRACEDWALL PANELSBLOCK THROUGH FLOORSYSTEM AT STRAPLOCATIONS AS REQ'DNOTEINFO APPLIES EQUALLY TO BOTH SIDES OF OPENING.BRACED WALL LINE BRACEDWALL LINE(4-FT)(4-FT)(4-FT)(4-FT)(4-FT) BRACED WALL LINE BRACED WALL LINE BRACEDWALL LINEBRACEDWALL LINE(4-FT)(4-FT)(4-FT)(4-FT)BRACEDWALL LINEBRACEDWALL LINECONSTRUCTPORTAL FRAMEAS SHOWN IN 4/S1BRACED WALL LINE (5-FT)(5-FT) BRACED WALL LINE (5-FT)(5-FT) BRACED WALL LINE (6-FT) BRACED WALL LINE (4-FT)(4-FT)(4-FT) (6-FT)(4-FT)(4-FT)(4-FT) BRACED WALL LINE (4-FT)BRACED WALL LINE (5-FT)(5-FT)(4-FT)(5-FT)(4-FT)(4-FT)CONSTRUCTPERFORATEDSHEAR WALL ASSHOWN IN 5/S1(5-FT)(3.9-FT)(4-FT)(4-FT)USE SIMPSON STHD14EMBEDED HOLDOWNANCHOR AND OMIT (3)16d NAILS EVERY 16"FOR X407 MODEL.REFER TO 6/S1 FORALTERNATIVE OPTION.S1FRAMING DETAILGARAGE FRONT PORTAL FRAME4NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.16'-3"±NOT TO EXCEED 12'-0"FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT STUD EACH END OF HEADERLOCATE PANEL JOINT WITHIN 2'-0" FROMCENTER OF HEADER HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(4) 2x6 BEARING STUDS MIN.(2) 2x6 BEARING STUDS MIN. @ SIM.(VERIFY w/ SUPPLIER)PROVIDE 2x6 INFILL WALLABOVE HEADER AS REQ'DSIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 6/S1 FOR ALTERNATIVE OPTION)FOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADER(2) 58" Ø ANCHOR BOLTS (7" MIN. EMBED)w/ 2" x 2" x 316" PLATE WASHERSNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/ (2)ROWS 8d NAILS @ 3" O.C. STAGGERED & TOPLATES / BLOCKING @ 3" O.C.)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.LARGE HATCH AREA INDICATES 716" OR THICKERPLYWOOD OR OSB SHEATHING APPLIED TO EXTERIORSIDE OF STUDS w/ STANDARD 6"/12" NAILINGFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELS2'-412"±2'-412"± Date Certificate Posted X Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here R-10 X R-10 X X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X Not applicable, all ducts located in conditioned space R8 Not required per mech. code X Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:60,000 Capacity in Gallons:Other, describe: AFUE or HSPF%92% Cfm's 4" " round duct OR " metal duct X Not required per mech. code Passive Low: Other, describe: X Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Output in Tons:2Endless Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM 301 61 Capacity continuous ventilation rate in cfms: powder, main, master SENSEI160 BA13NA024 Model Heating System Nat Gas Bryant Interior Interior Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type RINNAI Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13SEER /EER 912SD Manufacturer Bryant Nat GasTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.32 Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) Mech Room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 49,415 Heating Gain Cooling Load 61 121 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation Heating Loss Combustion Air Select a Type Location of duct or system: 21,029 Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor Silver Tree Plumbing and Heating MN License Number MB005441 City Mailing Address of the Dwelling or Dwelling Unit 4880 171st Street West THERMAL ENVELOPE Foam Open Cell Wall Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.32 Appliances Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM R10 ExteriorNon or Not Applicable Cooling System Builders Associaton of Minnesota version 101014 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2023-May-12 10:48:01Right-Suite® Universal 2022 22.0.01 RSU64702 Page 1 ...nts\Wrightsoft HVAC\DRH- X427- Holcombe SOG.rup Calc = MJ8 Front Door faces: E Job:Load Short Form 5/12/23Date:Entire House By: Silver Tree Plumbing and Heating LLC 1335 Mendota Heights Rd, Mendota Heights, MN 55120 Phone: 651-319-4200 Email: andyf@silvertreepandh.com Web: www.silvertreepandh.com Project Information DRH- X427- Holcombe SOGFor: Design Information InfiltrationClgHtg SimplifiedMethod88-15Outside db (°F)Semi-tightConstruction quality7270Inside db (°F) 1 (Semi-tight)Fireplaces1685Design TD (°F) M-Daily range 5030Inside humidity (%)5030Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Bryant Make Bryant Trade Bryant Legacy Line 92 Gas Furn...Trade BRYANT HEATING AND COOLING SYS...Model 912SD42060E17 Cond BA14NA02400G0A0 AHRI ref 0 Coil CNPVP2417ALA+912SD30040E14 AHRI ref 203018318Efficiency92.1 AFUE Efficiency 11.5 EER, 15 SEER Heating input Btuh60000 Sensible cooling Btuh17760 Heating output Btuh56000 Latent cooling Btuh4440 Temperature rise °F71 Total cooling Btuh22200 Actual air flow cfm740 Actual air flow cfm740 Air flow factor cfm/Btuh0.017 Air flow factor cfm/Btuh0.041 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.83 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room2 888 21093 10227 349 415 Room4 888 12191 4387 202 178 Room5 499 11398 3633 189 147 Entire House 2276 44682 18247 740 740 Other equip loads 4733 319 Equip. @ 0.93 RSM 17229Latent cooling 3799 TOTALS 2276 49415 21029 740 740 Step 1: Draft Hood Fan Assisted 60000 Direct Vent Input:60000 Btu/hr & Power vent Draft Hood 0 Fan Assisted 160000 Direct Vent Input:160000 Btu/hr & Power vent Step 2: 616 ft^3 Step 3: Step 4:4a. Input:0 Btu/hr TRV:0 ft^3 4b. Input:0 Btu/hr RVFA:0 ft^3 Input:0 Btu/hr RVNFA:ft^3 TRV =0 +0 =0 ft^3 Ratio =616 /0 =#DIV/0! RF=1 -#DIV/0!= Input:0 Btu/hr CAOA=0 /3000 Btu/hr per in2 =0 in2 0 x #DIV/0!=#DIV/0!in2 CAOD =1.13 x #DIV/0!=#DIV/0!inCAOD = 1.13 multiplied by the square root of Minimum CAOA 1If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section 304. Step 8: Calculate Minimum CAOA. Minimum CAOA = CAOA multiplied by RF Minimum CAOA = Step 9: Calculate Combustion Air Opening Diameter (CAOD) #DIV/0! Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Total Btu/hr divided by 3000 Btu/hr per in^2 Use Non-Fan-Assisted Appliances column in Table E-1 to find Combustion Air Opening Area (CAOA): Step 5: Calculate the ratio of available interior volume to the total required volume. Step 6: Calculate Reduction Factor (RF). RF = 1 minus Ratio If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Total Required Volume (TRV) = RVFA + RVNFA Required Volume Non-Fan-Assisted (RVNFA) If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Determine air Changes per Hour (ACH)1Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method) Use Standard Method column in Table E-1 to find Total Required Volume (TRV) If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. Determine Required Volume for Combustion Air.Standard Method Use Fan-Assisted Appliances column in Table E-1 to find Total Btu/hr input of all combustion appliances (DO NOT COUNT DIRECT VENT APPLIANCES) The CAS includes all spaces connected to one another by code compliant openings.CAS Volume: Furnace/Boiler: Water Heater:(Not fan assisted) (Not fan Assisted) Required Volume Fan Assisted (RVFA) Complete vented combustion appliance information: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) 1346.6012 IFGC APPENDIX E, WORKSHEET E-1. Total Btu/hr input of all non-fan-assisted appliances If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Known Air Infiltration Rate (KAIR) MethodTotal Btu/hr input of all fan-assisted and power vent appliances (DO NOT COUNT DIRECT VENT APPLIANCES) 1994(1) to Present Pre 1994(2)1994(1) to Present Pre 1994(2) 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,05025,000 1,250 1,875 938 2,625 1,31330,000 1,500 2,250 1,125 3,150 1,57535,000 1,750 2,625 1,313 3,675 1,83840,000 2,000 3,000 1,500 4,200 2,10045,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,875 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,15065,000 3,250 4,875 2,438 6,825 3,41370,000 3,500 5,250 2,625 7,350 3,67575,000 3,750 5,625 2,813 7,875 3,93880,000 4,000 6,000 3,000 8,400 4,20085,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250105,000 5,250 7,875 3,938 11,025 5,513110,000 5,500 8,250 4,125 11,550 5,775115,000 5,750 8,625 4,313 12,075 6,038120,000 6,000 9,000 4,500 12,600 6,300125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613150,000 7,500 11,250 5,625 15,750 7,875155,000 7,750 11,625 5,813 16,275 8,138160,000 8,000 12,000 6,000 16,800 8,400165,000 8,250 12,375 6,188 17,325 8,663170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713190,000 9,500 14,250 7,125 19,950 9,975195,000 9,750 14,625 7,313 20,475 10,238200,000 10,000 15,000 7,500 21,000 10,500205,000 10,250 15,375 7,688 21,525 10,763210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,857 8,438 23,625 11,813230,000 11,500 17,250 8,625 24,150 12,075(1)The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is 0.20 ACH.(2)This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH. 1346.6014 IFGC APPENDIX E, TABLE E-1. Known Air Infiltration Rate (KAIR) Method (ft3) Fan Assisted Non-Fan-Assisted IFGC Appendix E, Table E-1 Residential Combustion Air Required Volume (Required Interior Volume Based on Input Rating of Appliances) Standard Method (ft3) Input Rating (Btu/hr) One or multiple power vent or direct vent appliances or no combustion appliancesA One or multiple fan-assisted appliances and power vent or direct vent appliancesB One atmospherically vented gas or oil appliance or one solid fuel applianceC Multiple atmospherically vented gas or oil appliances or solid fuel appliancesD 1a) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03 b) conditioned floor area (sf) (including unfinished basements) 2323 0 0Estimated House Infiltration (cfm): [1a x 1b] 348.45 0 0 0 2.a) Exhaust Capacity continuous exhaust-only ventilation systems (cfm): (not applicable to balanced ventilation systems such as HRV) 0 0 0 0 b) clothes dryer 135 135 135 135 c) 80% of largest exhaust rating (cfm): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) 240 0 0 0 d) 80% of next largest exhaust rating (cfm): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) 0 0 0 Total Exhaust Capacity (cfm): [2a+2b+2c+2d] 375 135 135 135 3.a) Makeup Air Requirement Total Exhaust Capacity (from above) 375 135 135 135 b) Estimated House Infiltration (from above) 348.45 0 0 0 Makeup Air Quantity (cfm): [3a – 3b] (if value is negative, no makeup air is needed) 26.55 135 135 135 4. For Makeup Air Opening Sizing, refer to Table 501.3.2 One or multiple power vent or direct vent appliances or no combustion appliancesA One or multiple fan-assisted appliances and power vent or direct vent appliancesB One atmospherically vented gas or oil appliance or one solid fuel applianceC Multiple atmospherically vented gas or oil appliances or solid fuel appliancesD Passive makeup air opening duct diameterE,F,G Type of opening or system (cfm) (cfm) (cfm) (cfm) (inches) Passive Opening 1-36 1-22 1-15 1-9 3Passive Opening 37-66 23-41 16-28 10-17 4 Passive Opening 67-109 42-66 29-46 18-28 5Passive Opening 110-163 67-100 47-69 29-42 6Passive Opening 164-232 101-143 70-99 43-61 7Passive Opening 233-317 144-195 100-135 62-83 8Passive Opening with Motorized Damper 318-419 196-258 136-179 84-110 9Passive Opening with Motorized Damper 420-539 259-332 180-230 111-142 10Passive Opening with Motorized Damper 540-679 333-419 231-290 143-179 11Powered Makeup AirH >679 >419 >290 >179 not applicable G Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed.H Powered makeup air shall be electrically interlocked with the largest exhaust system. Table 501.3.2 Makeup Air Opening Sizing Table for New and Existing Dwellings C Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmosphericallyvented gas or oil appliances and solid fuel appliance(s). E An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90-degree elbow to determine the remaining length of straight duct allowable. F If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. A Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustionappliances. B Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. Table 501.3.1 Procedure to Determine Makeup Air Quantity for Exhaust Equipment in Dwellings Use the Appropriate Column to Estimate House Infiltration A Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances. B Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. C Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. 4 5 X 15 =752323 2323 X 0.02 =46.46 Continuous Ventilation Requirement = Enter # of Bedrooms Ventilation 121.46 60.73 Sq Ft of Home (including unfinished basements etc) Total Ventilation Requirement = NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 Alexis Flores 4/26/24 X PM