HomeMy WebLinkAbout19177 Impala AveCITY OF LAKEVILLE
CERTIFICATION OF GRADING AND
FINAL PLACEMENT OF IRON MONUMENTS
Building Permit #: LA183539
Legal Description: Lot 2 Block 4
Subdivision: SUMMERLYN 8TH ADDITION
Address: 19177 Impala Avenue, Lakeville Minnesota
We
4 hereby certify that on 11th day of June 2021 an inspection of
this property was conducted by me or under my direct supervision and that the as -built
grades, elevations and drainage patterns of the site and building are in conformance
with the grading plan approved by the City Engineer or amendments previously
approved by the City Engineer. In addition, all property corner monuments are in place
as of this date. Exceptions noted.
I hereby certify that this survey, plan or report was prepared by me or under my direct
supervision and that I am a duly Licensed Land Surveyor under the laws of the State of
Minnesota.
Print Name: gWer Ji Hawkinson
Signature:
Date: June 14, 2021 MN License #: 42299
NOTE: ATTACH A COPY OF THE CERTIFICATE OF SURVEY SHOWING ALL AS -
BUILT GRADES, ELEVATIONS AND DRAINAGE PATTERNS
Approved subdivision grading plans should be obtained from the property owner or
developer. General questions relating to the building permit should be directed to the
Building Inspections Department at 952-985-4440. Questions relating to grading should
be directed to the Engineering Department at 952-985-4500.
Prior to release of the Grading Security, this document shall be filed with:
City of Lakeville
Engineering Department
20195 Holyoke Avenue
Lakeville, MN 55044
RECEIVED
By Alanna Sobottka at 4:30 pm, May 10, 2024
ob X 1052.]
3
0
IOSR.R X o
a5z.s 0
O
V X 10517
im1.0 lol
1051.2
N89049'30"W
129.93
House
�..
3 p
Rauch
4
I't
loss]
XIWR.3
"'
IO6R.6 X
105].]
. 106R9
%1055.9
%1059.6
1
1060.8
x 10l xlower
x1057.3
X10W.5 Ia60.4x
nse.
-1
z Ixer.
x 1060.0
1
x Ideas
Io5B.3 x m
1
m55.1 x
1053.5
zIP5B3 105s..
Ia59.a'�.
%ideas
do
N
� '
r----
10
mas}
cx.
iRd
%105<.0
x
le ]x
%IOSJ.}
lessr
51.7
x1.z
%IOSA9
_
X1.12B
I05A9%
a
1o55A
m o.e
x.% xlosa.o
la 2 x
L
x105A1
x1000.5
0.
x1052R
I
Y
x losae
x 10A.a
1we.e
xlasl.e
I05ABx
os3a
%1➢51.0
1053Jx
1018
T.
%1059.O �TAl
\
I 1
100].R 1059.E %105B.fi 1059.3
.1059.Ot' ,�10603 D 1\ lo50o
I M .nm e \ Ia5B.3
1@,_n 7Ln___________ _10N3 ^1s
zp.a.5zmpPo1151
"s rain.] ao%sstI.pl
5 10
dw.e 109e.0x X 109:.8
\ %1aK.] x1019.'
\\
\ i % ID50.1
\ Rauch
N89049'30eW
Lot area we 9836 SF
House area = 2068 SF
Porch area se 137 SF
Sidewalk area = 44 SF
Driveway area a 759 SF
Total Impervious Area = 3008 SF
Impervious Coverage - 30.67.
deal O N \\
3 x Itils . \ % 1056.
> as
o \
1060.1 \
1051
�losaz 'u
x 1058.8 \
x 1050.]
lose.. \\
A. 5.8 loss'%1056.fi %'ds].9�D
1o5a5 x1o5e.z
iness xlos..l
I 1055.1 m5�.+-
1054.8 ,nn ex
0 1052.6 xon.1 % x waao 1057.6 % x 105TS
1057n lo5.9 ■
1A5].!x x 1.7.9
1050R % % 1050.0
mse.3
%Im24 1058.5 1059.1
losel
Ouse
153.24
• Denotes Iron pipe
4& Denotes service
0 Denotes television box
■ Denotes electric box
0 Denote: telephone box
X 000.00 Denotes existing elevation
( 000.00 ) Deceit .. prepneea w.vo n
y Denote: drainage flow direction
Denotes .pike
Construction Notes uuue Denotes proposed retaining wall
1. Install rock construction entrance. deigned and built by others.
2. Install silt fence as needed for are sion Control.
3. Sidewalks shall drain away from house a minimum of 1.0%.
4. Contractor must verify driveway design.
5. Contractor must verify service elevation prior to REVISED
an.tru
S. Add or remove foundation ledge as required.
General Notes:
1. Grading plan by Pioneer last dated 8-1-19 was used to determine proposed
ovations shown herein.
2. This survey does not purport to show improvements or encroachments,
except as shown, as surveyed by me or under my direct supervision.
3. Proposed building dimensions shown are for horizontal location of structures
n the lot only. Contact builder prior to construction for opproved construction
plans.
4. No specific sails investigation has been performed on this lot by the surveyor.
The suitability of soils to support the specific house proposed is not the
responsibility of the surveyor.
5. This certificate does not purport to show easements other than those shown
n the recorded plot.
6. Bearings shown are based on an assumed datum.
Lowest opening elevation per grading plan :1055.5
Lowest floor elevation per grading plan :1052.0
House elevations (Proposed) / As-b1dR
Lowest Footing Elevation :(1052.3) / 1052.0 ETO
Tap Of Foundation Elev. :(1080.3) / 1080,3
Garage Slab Elev. ® Door :(1060.0) / 1080.1
T.O.F. Elevation ® Lookout: (1055.5) / 1055.5
6/11/21 GRADING AS -BUILT
We hereby certify to Lerner Corporation that this survey, plan or
report was prepared by me or under my direct supervision, and
that I am a duly licensed Land Surveyor under the laws of the
State of Minnesota, doted 07/27/20.
Signed: er Engineering, P.A.
BY:
eno
eyar
MinnesotaLicense No. 42299 email9 ph awkinson 0pioneereng. earn
\1
losel
losel
0' 10' 20'
Scale: 1" = 20'
Benchmark:
Top Nut Hydrant
Lot 1 Block 4
Elevation = 1063.28
PIONE7� � Lot 2, Block 4,
ERCY1gneei"LYIg',PA SUMMERLYN M ADDITION Certificate of Survey for:
according to the recorded plat thereof Lennar Corporation
2422 Enterprise Drive 1h.:(651)681-1914 Dakota County, Minnesota
Mendota Heights, MN 55120 For: (651)681-9488 16305 36th Ave N Ste 4600
wwv,poreencng.com Address: 19177 Impala Avenue, Lakeville, Minnesota Plymouth, MIN 554464270
House Model: McKinley Elevation: B3 Phone:(952)249-3000/Fsx:(952)4041909
Projed#:119237018 Folder#:82581)qawnby:CWM Buyer: Walters
n Pioneer Enouroo ne