HomeMy WebLinkAbout19177 Impala AveCITY OF LAKEVILLE CERTIFICATION OF GRADING AND FINAL PLACEMENT OF IRON MONUMENTS Building Permit #: LA183539 Legal Description: Lot 2 Block 4 Subdivision: SUMMERLYN 8TH ADDITION Address: 19177 Impala Avenue, Lakeville Minnesota We 4 hereby certify that on 11th day of June 2021 an inspection of this property was conducted by me or under my direct supervision and that the as -built grades, elevations and drainage patterns of the site and building are in conformance with the grading plan approved by the City Engineer or amendments previously approved by the City Engineer. In addition, all property corner monuments are in place as of this date. Exceptions noted. I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed Land Surveyor under the laws of the State of Minnesota. Print Name: gWer Ji Hawkinson Signature: Date: June 14, 2021 MN License #: 42299 NOTE: ATTACH A COPY OF THE CERTIFICATE OF SURVEY SHOWING ALL AS - BUILT GRADES, ELEVATIONS AND DRAINAGE PATTERNS Approved subdivision grading plans should be obtained from the property owner or developer. General questions relating to the building permit should be directed to the Building Inspections Department at 952-985-4440. Questions relating to grading should be directed to the Engineering Department at 952-985-4500. Prior to release of the Grading Security, this document shall be filed with: City of Lakeville Engineering Department 20195 Holyoke Avenue Lakeville, MN 55044 RECEIVED By Alanna Sobottka at 4:30 pm, May 10, 2024 ob X 1052.] 3 0 IOSR.R X o a5z.s 0 O V X 10517 im1.0 lol 1051.2 N89049'30"W 129.93 House �.. 3 p Rauch 4 I't loss] XIWR.3 "' IO6R.6 X 105].] . 106R9 %1055.9 %1059.6 1 1060.8 x 10l xlower x1057.3 X10W.5 Ia60.4x nse. -1 z Ixer. x 1060.0 1 x Ideas Io5B.3 x m 1 m55.1 x 1053.5 zIP5B3 105s.. Ia59.a'�. %ideas do N � ' r---- 10 mas} cx. iRd %105<.0 x le ]x %IOSJ.} lessr 51.7 x1.z %IOSA9 _ X1.12B I05A9% a 1o55A m o.e x.% xlosa.o la 2 x L x105A1 x1000.5 0. x1052R I Y x losae x 10A.a 1we.e xlasl.e I05ABx os3a %1➢51.0 1053Jx 1018 T. %1059.O �TAl \ I 1 100].R 1059.E %105B.fi 1059.3 .1059.Ot' ,�10603 D 1\ lo50o I M .nm e \ Ia5B.3 1@,_n 7Ln___________ _10N3 ^1s zp.a.5zmpPo1151 "s rain.] ao%sstI.pl 5 10 dw.e 109e.0x X 109:.8 \ %1aK.] x1019.' \\ \ i % ID50.1 \ Rauch N89049'30eW Lot area we 9836 SF House area = 2068 SF Porch area se 137 SF Sidewalk area = 44 SF Driveway area a 759 SF Total Impervious Area = 3008 SF Impervious Coverage - 30.67. deal O N \\ 3 x Itils . \ % 1056. > as o \ 1060.1 \ 1051 �losaz 'u x 1058.8 \ x 1050.] lose.. \\ A. 5.8 loss'%1056.fi %'ds].9�D 1o5a5 x1o5e.z iness xlos..l I 1055.1 m5�.+- 1054.8 ,nn ex 0 1052.6 xon.1 % x waao 1057.6 % x 105TS 1057n lo5.9 ■ 1A5].!x x 1.7.9 1050R % % 1050.0 mse.3 %Im24 1058.5 1059.1 losel Ouse 153.24 • Denotes Iron pipe 4& Denotes service 0 Denotes television box ■ Denotes electric box 0 Denote: telephone box X 000.00 Denotes existing elevation ( 000.00 ) Deceit .. prepneea w.vo n y Denote: drainage flow direction Denotes .pike Construction Notes uuue Denotes proposed retaining wall 1. Install rock construction entrance. deigned and built by others. 2. Install silt fence as needed for are sion Control. 3. Sidewalks shall drain away from house a minimum of 1.0%. 4. Contractor must verify driveway design. 5. Contractor must verify service elevation prior to REVISED an.tru S. Add or remove foundation ledge as required. General Notes: 1. Grading plan by Pioneer last dated 8-1-19 was used to determine proposed ovations shown herein. 2. This survey does not purport to show improvements or encroachments, except as shown, as surveyed by me or under my direct supervision. 3. Proposed building dimensions shown are for horizontal location of structures n the lot only. Contact builder prior to construction for opproved construction plans. 4. No specific sails investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5. This certificate does not purport to show easements other than those shown n the recorded plot. 6. Bearings shown are based on an assumed datum. Lowest opening elevation per grading plan :1055.5 Lowest floor elevation per grading plan :1052.0 House elevations (Proposed) / As-b1dR Lowest Footing Elevation :(1052.3) / 1052.0 ETO Tap Of Foundation Elev. :(1080.3) / 1080,3 Garage Slab Elev. ® Door :(1060.0) / 1080.1 T.O.F. Elevation ® Lookout: (1055.5) / 1055.5 6/11/21 GRADING AS -BUILT We hereby certify to Lerner Corporation that this survey, plan or report was prepared by me or under my direct supervision, and that I am a duly licensed Land Surveyor under the laws of the State of Minnesota, doted 07/27/20. Signed: er Engineering, P.A. BY: eno eyar MinnesotaLicense No. 42299 email9 ph awkinson 0pioneereng. earn \1 losel losel 0' 10' 20' Scale: 1" = 20' Benchmark: Top Nut Hydrant Lot 1 Block 4 Elevation = 1063.28 PIONE7� � Lot 2, Block 4, ERCY1gneei"LYIg',PA SUMMERLYN M ADDITION Certificate of Survey for: according to the recorded plat thereof Lennar Corporation 2422 Enterprise Drive 1h.:(651)681-1914 Dakota County, Minnesota Mendota Heights, MN 55120 For: (651)681-9488 16305 36th Ave N Ste 4600 wwv,poreencng.com Address: 19177 Impala Avenue, Lakeville, Minnesota Plymouth, MIN 554464270 House Model: McKinley Elevation: B3 Phone:(952)249-3000/Fsx:(952)4041909 Projed#:119237018 Folder#:82581)qawnby:CWM Buyer: Walters n Pioneer Enouroo ne