Loading...
HomeMy WebLinkAboutLA224707 - APPROVED-PLANSCOVER SHEETPHOTOVOLTAIC ROOF MOUNT SYSTEMREVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-0 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLE2VICINITY MAPSCALE: NTSPV-01AERIAL PHOTOSCALE: NTSPV-0PV-0COVER SHEETPV-1SITE PLAN WITH ROOF PLANPV-2ROOF PLAN WITH MODULESPV-3ATTACHMENT DETAILSPV-4 ELECTRICAL LINE DIAGRAM &CALCULATIONPV-5 PLACARDS & WARNINGPV-6+EQUIPMENT SPEC SHEETSSHEET INDEXGOVERNING CODES:PROJECT SITEARRAY LOCATIONSGENERAL NOTES·ALL ELECTRICAL WORK SHALL BE PERFORMED BY A QUALIFIED LICENSEDELECTRICIAN AND/OR APPRENTICES WORKING UNDER THE DIRECTSUPERVISION OF THE LICENSED CONTRACTOR.·ALL WORK CARRIED OUT SHALL COMPLY WITH THE SPECIFICATIONS,APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCALJURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS.·PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL NOTIFYTHE ENGINEER OF AN DISCREPANCIES NOTED AMONG SITE CONDITIONS,MANUFACTURER RECOMMENDATIONS, OR AUTHORITY HAVING JURISDICTION. IFTHE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESEDRAWINGS, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER OF RECORD AWRITTEN "RFI"(REQUEST FOR INFORMATION) PROPOSING AN ALTERNATIVE ORSEEKING CLARIFICATION.·THE CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OFPLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THEPREMISES AT ALL TIMES.·UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHINGMATERIALS, EQUIPMENT, ACCESSORIES, AND LABOR NECESSARY TO COMPLETEALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.·ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCEWITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTORSHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS,ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLICAUTHORITY REGARDING THE PERFORMANCE OF WORK.·THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS INACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESSSPECIFICALLY STATED OTHERWISE.·CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA,ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BEAFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TOALL OSHA REQUIREMENTS AND THE LOCAL JURISDICTION.·FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FORALL ROOF WORK.·WHEN INSTALLING IN FIRE RATED AREAS, SEAL ALL PENETRATIONS WITH ULLISTED MATERIALS APPROVED BY LOCAL JURISDICTION. CONTRACTOR SHALLKEEP AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS.·CONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION. ALL DEBRIS ANDOTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN ALAWFUL MANNER.·THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS,CURBS, LANDSCAPING AND STRUCTURES NOT PART OF THE SCOPE OF WORKAS IDENTIFIED IN THESE PLANS.·THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FORTHE DURATION OF CONSTRUCTION UNTIL JOB COMPLETION.·DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY AREEXPOSED TO LIGHT, CONTRACTOR SHALL DISABLE THE ARRAY DURINGINSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, ORCOVERING ARRAY WITH AN OPAQUE COVER ACCORDING TO MANUFACTURER'SINSTRUCTION.·CONSTRUCTION LOADING ON THE ROOF, SUCH AS MATERIAL STAGED ON THEROOF, SHALL BE LIMITED TO 20 PSF. CONCENTRATED LOADING SHALL BEAVOIDED TO PREVENT LOCALIZED DAMAGE TO THE ROOF.2020 MINNESOTA RESIDENTIAL CODE2020 MINNESOTA BUILDING CODE2020 MINNESOTA ENERGY CODE2020 MINNESOTA ACCESSIBILITY CODE2020 MINNESOTA MECHANICAL AND FUEL GAS CODE2020 MINNESOTA PLUMBING CODE2020 MINNESOTA CONSERVATION CODE FOR EXISTING BUILDINGS2020 MINNESOTA FIRE CODE2023 NATIONAL ELECTRICAL CODE (NEC)21 MODULES-ROOF MOUNTED - 8.61 kWDC, 6.83 kWAC6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USASYSTEM SUMMARY(N) 21 - SILFAB SOLAR SIL-410 BG (410W) MODULES(N) 21 - ENPHASE ENERGY IQ8M-72-2-US MICRO-INVERTERS(N) JUNCTION BOX(N) ENPHASE IQ COMBINER BOX 4(E) 100A MAIN SERVICE PANEL WITH (E) 100A MAIN BREAKER(N) 60A FUSED AC DISCONNECT(N) PV PRODUCTION METERDESIGN CRITERIAROOF TYPE:- ASPHALT SHINGLENUMBER OF LAYERS:- 1ROOF FRAME:- 2"X4" RAFTERS @ 24" O.CSTORY:- ONE STORYSNOW LOAD:- 50 PSFWIND SPEED:- 115 MPHWIND EXPOSURE:- BRISK CATEGORY:- IICOORDINATE:- 44.706686, -93.199938Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode06/13/2024jnuetzman CBACDPVMUMMSPJB~ 1 3 4 . 7 9 '~100.00'~ 1 3 5 . 2 9 '~115.92'2 7 ' - 7 "33'-8"61'-0"1'-11"CBACDPVMUMMSPJBSITE PLAN WITH ROOF PLANREVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-1 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLESITE PLAN WITHROOF PLAN1SCALE: 3/64" = 1'-0" ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THEPLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONSWHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONSSUCH AS TREE LIMBS, WIRES OR SIGNS.NOTE:A.ALL ELECTRICAL EQUIPMENT, INVERTERS,DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALLNOT BE INSTALLED WITHIN 3’ OF THE GAS METERS’SUPPLY OR DEMAND PIPING.NOTE:- ALL EQUIPMENT SHOULD BEPLACE 36" AWAY FROM GAS METERNOTE:3/4" OR GREATER EMT CONDUITRUN INSIDE ATTICROOF ACCESS POINTTHERE IS NO FENCE OR GATE INTHIS PROPERTYLEGENDPVMPV PRODUCTION METERCBCONDUITPROPERTY LINETREESAC DISCONNECTACDUTILITY METERUMMSPMAIN SERVICE PANELENPHASE IQ COMBINER 4JUNCTION BOXJBPROPERTY LINEPROPERTY LINE PROPERTY L INEPROPERTY LINE(N) 3/4" OR GREATER EMT CONDUITRUN (INSIDE ATTIC)(N) ENPHASE IQCOMBINER BOX 4VENT, ATTIC FAN(ROOF OBSTRUCTION)ONE- STORYHOUSEEXIS T INGDRIVEW AY UPPER 167TH ST W(E) TREES (TYP.)168TH S T W CBACDPVMUMMSPJB9'-0"30'-9"8'-11"6' - 6 " 1 8 ' - 5 " 4' - 7 "3"9'-6"5'-0"2"11'-5" 3' - 2 "REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-2 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLEROOF PLAN WITHMODULESROOF PLAN WITH MODULESSCALE: 1/8" = 1'-0"1· PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED.NOTE:3/4" OR GREATER EMT CONDUITRUN INSIDE ATTICBILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONRAIL14UNIRAC NXT UMOUNT RAIL 168"DARKSPLICE8NXT UMOUNT RAIL SPLICEUNIVERSAL CLAMP52NXT UMOUNT COMBO CLAMP - DARKROOF ATTACHMENT55UNIRAC FLASHLOCACCESSORIES20NXT UMOUNT RL & CLMP CAP KITMLPE & GROUNDING26NXT UMOUNT MLPE & LUG CLAMP(N) 3/4" OR GREATER EMTCONDUIT RUN (INSIDE ATTIC)LEGENDJBJUNCTION BOXUMUTILITY METERPVMPV PRODUCTION METERACDAC DISCONNECTMSPMAIN SERVICE PANELCBENPHASE IQ COMBINER BOX 4ENPHASE ENERGY IQ8M-72-2-USMICRO INVERTERCONDUITUNIRAC NXT UMOUNT RAILVENT, ATTIC FAN(ROOF OBSTRUCTION)RAFTERSROOF ATTACHMENT UNIRACFLASHLOC @ 48" O.C.ARRAY AREA & ROOF AREA CALC`SAREA OF NEW ARRAY(Sq. Ft.)AREA OF ROOF(PLANVIEW)(Sq. Ft.)TOTAL ROOF AREACOVERED BY ARRAY %433.522189.5419.8019.80%ROOF AREA (ARRAY <33% of ROOF AREA)NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM)LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FORATTACHMENTSPHOTOVOLTAIC MODULESSILFAB SOLAR SIL-410 BG (410W) 73.4" 40.5"MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 21 MODULESMODULE TYPE = SILFAB SOLAR SIL-410 BG (410W) MODULESMODULE WEIGHT = 45.8 LBS / 20.8 KGMODULE DIMENSIONS = 73.4" X 40.5" = 20.64 SFUNIT WEIGHT OF ARRAY = 2.22 PSFARRAY AREA & ROOF AREA CALC`SROOF# OFMODULESARRAYAREA(Sq. Ft.)ROOFAREA(Sq. Ft.)ROOFAREA COVEREDBY ARRAY (%)#115309.66492.2962.90#26123.86217.3057.00ROOF DESCRIPTIONROOF TYPEASPHALT SHINGLEROOFROOFTILTAZIMUTHRAFTERSSIZERAFTERSSPACING#122°232°2" X 4"24" O.C#222°142°2" X 4"24" O.C(N) ENPHASE ENERGYIQ8M-72-2-USMICRO-INVERTERSROOF #1TILT - 22°AZIMUTH - 232°ROOF # 2 T I L T - 2 2 °AZ IMU TH - 1 4 2 °UPPER 167TH ST WFRONT YARDREAR YARD18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PAT H W A Y 18" FIRE PATH W A Y 18" FIRE PATH W A Y 18" FIRE PATH W A Y 18" FIRE PATHWAY18" FIRE PATHWAY168TH S T WFIRE PATHWAYNOTE:THE AC DISCONNECT IS LOCATEDWITHIN 10FT OF UTILITY METERSYSTEM SIZE:- 21 x 410W = 8.61 kWDCSYSTEM SIZE:- 21 x 325VA = 6.83 kWACMinimum3'-0"accesspathway REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-3 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLEATTACHMENTDETAIL ENLARGE VIEWPV MODULESASPHALT SHINGLEROOF2.5" MIN.EMBEDMENT5/16" x 4" STAINLESS STEEL LAG BOLTW/ SS EPDM BONDED WASHERNXT UMOUNT COMBO CLAMPPV MODULES NXT UMOUNT RAIL STRONGHOLD RAIL CLAMPFLASHLOC BASEROOF / DECK MEMBRANEASPHALT SHINGLEROOF5/16"-18 x 2"SERRATED FLANGE HEX SCREW~4" HEIGHTADJUSTMENT1.38"~4"1.38"ATTACHMENT DETAILSCALE: NTS1ATTACHMENT DETAIL (ENLARGED VIEW)SCALE: NTS2NOTE: ACTUAL ROOF CONDITIONS AND RAFTERS (OR SEAM)LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FORATTACHMENTS(E) 2"X4" RAFTERS @ 24" O.C REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-4 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLEELECTRICAL LINEDIAGRAM WITHCALCULATIONE AS PER YOUR REQUIREMENTSCALE: NTSELECTRICAL LINE DIAGRAM WITH CALCULATION1NOTE"LOAD" ON THE BOTTOM OF THE METER IS FOR PV GENERATION"LINE" ON THE TOP OF THE METER IS FOR THE UTILITY.INVERTER SPECIFICATIONSMANUFACTURER / MODEL #QUANTITYNOMINAL OUTPUTVOLTAGENOMINAL OUTPUTCURRENTENPHASE ENERGYIQ8M-72-2-US21240VAC1.35AAMBIENT TEMPERATURE SPECIFICATIONSRECORD LOWTEMPERATUREAMBIENT TEMP(HIGH TEMP 2%)CONDUITHEIGHTCONDUCTORTEMPERATURERATE (ONROOF)CONDUCTORTEMPERATURERATE (OFFROOF)-26°32°IN ATTIC90°75°SERVICE INFOUTILITY PROVIDER: DAKOTA ELECTRICMAIN SERVICE VOLTAGE: 240VMAIN PANEL BRAND: N/AMAIN SERVICE PANEL: (E) 100AMAIN CIRCUIT BREAKER RATING: (E) 100AMAIN SERVICE LOCATION: SOUTH-WESTSERVICE FEED SOURCE: UNDERGROUNDL100AEXISTINGGROUNDINGSYSTEMLINE SIDE TAP(E) MAIN BREAKER100A/2P, 240V (E) MAINSERVICE PANEL,100A RATED,120/240VBI-DIRECTIONAL (N) UTILITY METER1-PHASE, 3-W,120V/240V, 60HzMLINELOAD(N) PRODUCTIONMETERCGNNL2L1L2L140A FUSES(N) AC DISCONNECT60A FUSED,WITH 40AFUSES 240 VACTERMINATOR CAP ON LAST CABLECONNECTOR Q-CABLE (TYP)(N) ENPHASE IQCOMBINER BOX 4(N) JUNCTION BOX10 MICRO-INVERTERS IN BRANCH #2GL1L1L2L2N20AG10A/15A20A11 MICRO-INVERTERS IN BRANCH #1L1L1L2L2ABM*IQ-GATEWAYSYSTEM SIZE:- 21 x 410W = 8.61 kWDCSYSTEM SIZE:- 21 x 325VA = 6.83 kWACSOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #VMP(V)IMP(A)VOC(V)ISC(A)TEMPERATURECOEFFICIENTOF VocQUANTITY OFMODULESSILFAB SOLARSIL-410BG (410W)38.0710.7745.9211.30-0.27%/°C21MODULE DIMENSIONS73.4"L x40.5"W x1.4"DWire TagConduitWire QtyWireGaugeWire TypeTemp.RatingWireAmpacity (A)Temp.DerateConduitFill DerateDeratedAmpacity (A)InverterQtyNOC (A)NECCorrectionDesignCurrent (A)GroundSizeGround WireTypeAOPEN AIR212 AWGQ Cable90°C300.96N/A28.80111.351.2518.5606 AWGBARE CUB3/4" EMT410 AWGTHWN-290°C400.960.8030.72111.351.2518.5610 AWGTHWN-2C3/4" EMT38 AWGTHWN75°C500.941.047.00211.351.2535.4410 AWGTHWND3/4" EMT36 AWGTHWN75°C650.941.061.10211.351.2535.4408 AWGTHWN(21) ENPHASE ENERGY IQ8M-72-2-USMICROINVERTERS (240V)(LOCATED UNDER EACH PANEL)(1-PHASE, 2 WIRES)NOTE:THE AC DISCONNECT IS LOCATEDWITHIN 10FT OF UTILITY METERNOTE:3/4" OR GREATER EMT CONDUITRUN INSIDE ATTICD REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-5 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLEWARNING LABELS &PLACARDPOWER TO THIS BUILDING IS ALSO SUPPLIED FROM THEFOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN(N) PV ARRAYCAUTION !MULTIPLE SOURCES OF POWER(E) UTILITY METER(E) 100A MAIN SERVICE PANELWITH (E) 100A MAIN BREAKER(N) PV PRODUCTION METER WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMLABEL LOCATION:EMT/CONDUIT RACEWAYS(PER CODE: NEC 690.31(D)(2)PHOTOVOLTAIC POWER SOURCELABEL LOCATION:POINT OF INTERCONNECTIONPRODUCTION METERNEC 705.30(C) & NEC 690.59NOTES AND SPECIFICATIONS:·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE2023 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONSARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THELOCAL AHJ.·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDSUSING EFFECTIVE WORDS, COLORS AND SYMBOLS.·LABELS SHALL BE PERMANENTLY AFFIXED TO THEEQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN.·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTANDTHE ENVIRONMENT INVOLVED.·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISESPECIFIED.·DO NOT COVER EXISTING MANUFACTURER LABELS.ELECTRICAL SHOCK HAZARDWARNINGTERMINALS ON LINE AND LOADSIDES MAY BE ENERGIZED INTHE OPEN POSITIONLABEL LOCATION:INVERTER(S), AC DISCONNECT(S), ACCOMBINER PANEL (IF APPLICABLE).PER CODE(S): NEC 2023: NEC 705.20(7) &NEC 690.13(B)MAXIMUM AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE: 28.35 AMPS 240 VACLABEL LOCATION:AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTION.PER CODE(S): NEC 2023: 690.54SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAP ID SHUTDOWNSWITCH TO THE "OFF"POSIT ION TO SHUT DOWNPV SYSTEM AND REDUCESHOCK HAZARD IN THEARRAY.LABEL LOCATION:MAIN SERVICE PANELPER CODE(S): NEC 2023: IFC 605.11.3.1(1) & 690.12(D)!3"2"PHOTOVOLTAIC SYSTEM AC DISCONNECTMAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION:MAIN SERVICE DISCONNECT / UTILITY METER(PER CODE: NEC 690.13(B))LABEL LOCATION:UTILITY SERVICE ENTRANCE/METER(WITHIN 3'),INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ,OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.PER CODE(S): NEC 2023: 690.12(D)(2)RAPID SHUTDOWN FORSOLAR PV SYSTEM!PHOTOVOLTAICAC DISCONNECTLABEL LOCATION:AC DISCONNECTNEC 690.13(B)WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENT!LABEL LOCATION:COMBINER BOXPER CODE: NEC 690.31(E)THIS EQUIPMENT FED BYMULTIPLE SOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEEDAMPACITY OF BUSBARWARNINGLABEL LOCATION: POINTS OF CONNECTION/BREAKERCODE: NEC 705.12(B)(3)(3)WARNINGPOWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICE!LABEL LOCATION:SERVICE PANEL IF SUM OF BREAKERS EXCEEDSPANEL RATINGNEC 705.12 (B)(3)(2)!LABEL LOCATION:MSP (PER CODE: NEC 705.12(D)(2) &NEC 690.59CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED!(N) 60A FUSED AC DISCONNECT(N) COMBINER BOX 46630 UPPER 167TH ST W168TH ST W REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-6 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLESPEC SHEET REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-7 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLESPEC SHEETS REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-8 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLESPEC SHEETS REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-9 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLESPEC SHEETS REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-10 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLESPEC SHEETS REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-11 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLESPEC SHEETS REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-12 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLESPEC SHEETS REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-13 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLESPEC SHEETS REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-14 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLESPEC SHEETS REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-15 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLESPEC SHEETS REVDATEDESCRIPTIONVERSIONUR05-21-2024INITIAL RELEASESHEET NAMESHEET NUMBERPV-16 PROJECT NAMESHEET SIZEANSI B11" X 17"ISOLAR LLC455 BROADWAY AVE, SAINTPAUL PARK, MN 55071TEL: (563) 202-0018LICENSE #: EA761814Email - dan@isolarmn.comANNA TAFT 6630 UPPER 167TH ST W, ROSEMOUNT, MN 55068, USA UTILITY: DAKOTA ELECTRIC APN: 222117402010 AHJ: CITY OF LAKEVILLESPEC SHEETS