Loading...
HomeMy WebLinkAboutLA225102 - 17997 Hidden Creek Tr-Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND 17997 HIDDEN CREEK TR, LAKEVILLE, MN 55044*ALL DOOR & WINDOW HEADERSTO BE S.P.F. #2 OR BETTERRESIDENCE FOR:written consent of Planco MN, Inc. modified or used in any redesign without the priormay not be assigned or copied, and may not bemay not be re-used for any additional structures,structure. Planco MN reserves all rights. These planslicense is granted to use these plans to build oneCopyright for these drawings is owned by Planco MN,Planco MN, Inc.cDOMINGUEZ BELLEPAR HOMES#24-031SMA182024ALUM. SOFFIT & FASCIAALL SIDESTHERMO-TECHWINDOWS FRONT ELEVATION 1/4" = 1'-0" 8'-4" POURED FOUNDATION9' CEILING @ FIRST FLOOR6" TRIMTOTAL2nd FLR.1st FLR.1,271 SQ. FT.1,030 SQ. FT.2,301 SQ. FT.CONC. PORCH1286121284" VINYL SIDING1256" TRIM SIDES & REARBOARD6" FRIEZEWDW. GRIDS AS SHOWNFRONT ONLY12x12 BOXED COL.ON 18x18x42STONE BASELP B & BLP B & BRIDGE VENT6121'-0"1'-6"VINYL B & BSIDES & REARGLASS @ TOP PANEL8x7 OVH. DR.LP B & BFRONT ONLY7" EXPOSURE LP SIDINGFRONT ONLYSTONE AS SHOWNFRONT ONLY7" EXPOSURELP SIDING7" EXPOSURELP SIDING(2) 11x20 FYPON7" EXPOSURELP SIDING5'-0"STONECAPSTONEGLASS @ TOP PANEL16x7 OVH. DR.6" TRIMConcept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode06/25/2024jnuetzman VERIFY ALLGRADE LINESPlanco MN, Inc.C#24-031SMA282024 LEFT ELEVATION 1/8" = 1'-0" 6126" FRIEZEBOARD6" TRIMVINYL B & BVINYLSIDINGLPSIDING RIGHT ELEVATION 1/8" = 1'-0" 1266" FRIEZEBOARD6" TRIMVINYL B & BVINYLSIDINGVINYLSIDING1262'-0"2'-0"LPSIDINGLPSIDING REAR ELEVATION 1/8" = 1'-0" 6126" TRIMVINYLSIDINGEGRESSWDW. WELL16' DECK LEDGERSecure door closed until deck isconstructed with a separate permit. Planco MN, Inc.C#24-031SMA38202445'-0"15'-0"35'-10"5'-10"46'-10" 24'-6"30'-0" BASEMENT PLAN 1/4" = 1'-0" 22'-4" 18" FLR.TRUSS 19.2" O.C. UNEXCAVATED FURN MECH *UNFINISHED14'-6"2'-4"92%F.D.WH2'-8"2'-8"UP16 R FUT. FAMILY/REC RM *UNFINISHED35'-10" 15'-2" 18" FLR.TRUSS 19.2" O.C. 13'-4"WALLWALLEDGE7'-4"EDGESUMP3'-8"3'-8"4'-0"24'-6"11'-6"2'-6" FUT. BDRM *UNFINISHED20x8 FTG.1/2C. - 6" BLK.2x6 - 16" O.C.1/2C. - 6" BLK.20x8 FTG.2x6 - 16" O.C.GIRDER FLOOR TRUSS2-9 1/2" LVL FLUSH2-2x104'-0"6'-3"3'-11"SD/CO483410"48"1/2 WALLW/ WD. CAP6'-5"8'-4" POURED FOUNDATION2'-0"LIN.6'-4"8'-4"3'-0"30"x30"x12"CONC. PAD FTG.30"x30"x12"CONC. PAD FTG. UNEXCAVATED 2'-0"22'-6"9'-2"20'-6"5'-0" BI-PASS2'-6"2-9 1/2" LSLTC 3042 E2-9 1/2" LSLTS 60422" FOR R-10 INSUL.BRING FOUNDATION IN2" INSUL.2" INSUL.2" INSUL.2" INSUL.2" INSUL.2" LEDGE2" LEDGE13'-0"11'-2"10'-0"20'-0"LOOKOUT1/2C. - 4" BLK.20x8 FTG.2x4 - 16" O.C.22'-10"15'-2"LOOKOUT 12'-0"1'-9"1'-9"3'-0" 2-2x10 TS 6042 6'-3"12'-0" 3/4 R.I. R.I. W & D UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.CS-WSPHTT4 HTT4CS-WSP CS-WSPCS-WSP Planco MN, Inc.C#24-031SMA4820249' CEILING @ FIRST FLOOR8'-7"36'-0"16x7 OVH. DR.13'-6"36'-0"45'-0" FIRST FLOOR PLAN 1/4" = 1'-0" 1,030 SQ. FT.*L.V.P. FOYER *CARPET OFFICE/BDRM GREAT ROOM UP17 R7'-0" KITCHEN 36" REF'G4'-3"4'-3"*L.V.P.2'-0"3'-4"4'-0"*L.V.P. DINING *L.V.P.15'-2"7'-4" 3'-8"4'-2"3'-8"5'-10"WALLEDGERAILWALLEDGE12" S.B.3'-0" CONC. PORCH 18" FLR.TRUSS 19.2" O.C.3"3"2-2x10TSH3660-2 GARAGE *4" CONC. FLOORHOODVENTGIRDER FLOOR TRUSS2-9 1/2" LVL FLUSH2x6PANT.12" SH'S2'-5"8'-6"18" FLR.TRUSS 19.2" O.C. 18" FLR.TRUSS 19.2" O.C.2x618" CANT.2-11 7/8" LVL10'-81 2" 22'-6" 72" BENCH 2'-8" S.R.O.2'-8"FIREDR.*L.V.T.*L.V.T. MUD RM 2'-4"2-9 1/2" LSL6'-0" P.D.5'-11"6'-0"30'-0"15'-0"2"9'-7"5'-3"10'-0"10'-0"7'-0"13'-6"24'-6" 47'-0" TRUSSES 24" O.C.5'-3"7'-7"2'-2"SD/COTRUSSES24" O.C.13'-0"11'-0" 6'-8"9'-8" 12'-9"*SHTRK WALLS & CLG.2'-0"TSH 30483-2x102'-0"6'-2"2'-10"F*INSUL. @ BEDROOM FLOOR ABOVE5'-1"3'-6"*PROVIDE 16' DECK LEDGER FUT. DECK 30" D.Z.2-9 1/2" LVLFLUSH2-9 1/2" LVL2-2x102-2x103-2x10TSH 3666-3TOP @ 7'-11"ELEC. F.P. 2'-912"9'-7"2'-912"OVEN/MICRODN16 R*2x6 WALLS8x7 OVH. DR.20'-0"10'-0"4'-8"5'-4"2626 FX TOP @ 7'-11" 2-2x10 2626 FX TOP @ 7'-11" 2-2x10 5'-1"5'-0"8"9'-0"GIRDERGIRDER GIRDER TRUSSES 24" O.C. 2'-0"22'-6"16'-0"10"12x12 BOXED COL.ON 18x18x42STONE BASE3-14" LVL4'-3" 18" FLR.TRUSS 19.2" O.C. 18" FLR.TRUSS 19.2" O.C.GAS COOKTOPCHASE6'-6"13'-0"27'-5"2'-6"4'-0"2'-10"10'-8"6'-8"3'-6"5'-4"1'-6" 48 34LIN.2'-0"4'-8" 36"2x64'-0"3'x3'CONC.PAD2-2x103'-0"-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).BWPsAboveBWPsAboveSmokePFHSTHD14STHD14PFHSTHD14STHD14PFHSTHD14STHD14LSTH8Temper8 Planco MN, Inc.C#24-031SMA58202436'-0" SECOND FLOOR PLAN 1/4" = 1'-0" BEDROOM #2 *CARPET14'-6" MASTER BEDROOM *CARPET W.I.C. *CARPET1,271 SQ. FT.2'-4"10'-0"15'-0" 37'-6"10'-6"1'-6" BEDROOM #3 *CARPET12'-6"2'-8"7'-4"2'-6"1/2 WALLDN17 R4'-2"3'-8"3'-8"2'-6"5'-10"WALLEDGE60"WALLEDGE3260 TUB& SHOWER11'-6"TSH4060-2 E2-9 1/2" LVL BEDROOM #4 *CARPETTSH4060 E2-2x1011'-4"2'-4"11'-10"2'-4"2'-0"2'-0"8'-1" 14'-9"5'-10"WDTSH 4060-2 E2-2x10TSH 3660 TEMP 2-2x10 TOP @ 7'-0" OFF LANDING *L.V.T.*VINYLSDSDSDSDSD/COF5'-1"5'-3"5'-3"TRUSSES 24" O.C. TRUSSES 24" O.C.2x66'-3"5'-3"7'-6"7'-0"3'-9"6'-3"2-2x101'-9 3 16"8'-0"2x6ACCESS ATTICTRUSSES24" O.C.3'-8"3'-8" 2'-0" 34'-0"2'-6"2'-8"2'-0"LIN.6'-11"36'-0"5'-0"20'-6"2-2x10TSH 30422'-3"2'-9"TSH 4060 E 2-2x10 8'-3"3'-1" 2'-6"3'-0"3'-8"GIRDERTA 24242-2x106'-8"2'-6"11'-4"5'-3"6'-1"2'-11"3'-9"RIDGE OFVAULT*VAULTPKT.TSH24482'-4"PKT.4'-3"5'-5"*L.V.T.*C.T.FF2x62-2x10 TSH 2448 1'-8"3'-8"24"LIN.64482'-6"2'-4"9'-2"10"*L.V.T.72" 5'-0" BI-PASSTA 24242-2x105'-0" BI-PASS8'-4"1/2 WALL W/ GLASS PANEL2'-4" W.I.C. *CARPETFANTemper-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).CS-PFLSTA18 Strapopposite side ofsheathing fromheader to studbelow.CS-WSPCS-WSP Planco MN, Inc.C#24-031SMA682024SHEATHINGSIDING17 RISERS CROSS SECTION 3/8" = 1'-0" 2X6- 16" O.C.1/2 C- 6" BLK.18" FLOOR TRUSSES @ 19.2" O.C. “SHEATHINGSIDING5/8" GYP. BD.R-20 INSUL.R-21 SPRAY FOAM1/2" GYP. BD.VB2x6- 16" O.C.9'-11 8"PROVIDE DUCT CHASE16 RISERS 2X4- 16" O.C.1/2 C- 4" BLK.20X820X820X82X6- 16" O.C.1/2 C- 6" BLK.3 1/2" CONC. FLOOR2x6PROVIDE DUCT CHASE18" FLOOR TRUSSES @ 19.2" O.C.2x42x61'-6"R-21 SPRAY FOAMVB1/2" GYP. BD.R-20 INSUL.2x6- 16" O.C.3/4" T & G FLOOR36'-0"R-49 INSUL.R-21 SPRAY FOAMR-20 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.8'-11 8"3/4" T & G FLOORW/ V.B.5/8" GYP. BD.GIRDER2x6- 16" O.C.VB1/2" GYP. BD.R-20 INSUL.R-21 SPRAY FOAM(DESIGNED BY MFR)TRUSSES @ 24" O.C.1'-6"18" FLOOR TRUSSES @ 19.2" O.C.18" FLOOR TRUSSES @ 19.2" O.C.FASCIAALUM. ALUM.SOFFITVENTED1/2" SHTG.15# FELTSHINGLES2'-0"ENERGY HEEL612TO 14x14 PLYWOODGRADEBOXAPPLY STONE2-9 1/2" LVL6x6 POST6'-0"ALUM.VENTEDSOFFITFASCIAALUM. 1'-10"SHEATHINGSIDING2'-0"FASCIAALUM. ALUM.SOFFITVENTED125FLASHING CROSS SECTION 3/8" = 1'-0" 6'-2"5/8" GYP. BD.CONC. PORCH6'-8" MIN. HDRM1x8 RISERS5/4x11 TREADS4- 2x12 STRINGERSTAIR NOTES:10" RUFF CUT TREADS1-2x8 TREATED8'-4" POUREDWALL W/ REBARPER CODESILL PLATEWATER PROOFINGAS REQUIREDDRAIN TILE 20x8R-10 RIGID INSUL.1-2x8 TREATED8'-4" POUREDWALL W/ REBARPER CODESILL PLATEWATER PROOFINGAS REQUIREDDRAIN TILE 20x8R-10 RIGID INSUL.71 2"RIDGE VENTWATER DRAIN TILE AS REQUIREDPROOFINGPOURED WALLGRADE2X6- 16" O.C.R-21 INSUL.VB2" R-10RIGID INSUL.20x81-2x8 TREATEDSILL PLATE7 5 16" Planco MN, Inc.C#24-031SMA782024 “3 1/2" CONC. FLOORR-20 INSUL.1/2" GYP. BD.2x6- 16" O.C.R-21 SPRAY FOAMVBSIDINGSHEATHINGPROVIDE DUCT CHASE18" FLOOR TRUSSES @ 19.2" O.C.2x6- 16" O.C.VB1/2" GYP. BD.R-20 INSUL.R-21 SPRAY FOAM3/4" T & G FLOOR5/8" GYP. BD.9'-118" CROSS SECTION 3/8" = 1'-0" GARAGE 4" CONC. FLOOR5/8" TYPE "X" GYP. BD.GIRDERGRADE34'-0"13'-0"2x6- 16" O.C.1/2" GYP. BD.R-20 INSUL.R-21 SPRAY FOAMVBR-21 SPRAY FOAMR-20 INSUL.1/2" GYP. BD.VB2x6- 16" O.C.3/4" T & G FLOOR5/8" GYP. BD.W/ V.B.8'-118"18" FLOOR TRUSSES @ 19.2" O.C.FASCIAALUM. ALUM.SOFFITVENTED1/2" SHTG.15# FELTSHINGLES2'-0" ENERGY HEEL612R-49 INSUL.10'-93 8"SLOPE TO DOORSALUM.ALUM. FASCIASOFFITVENTED2'-0"ENERGY HEEL(DESIGNED BY MFR)TRUSSES @ 24" O.C.2x4- 16" O.C.1/2" GYP. BD.5/8" TYPE "X" GYP. BD.(DESIGNED BY MFR)TRUSSES @ 24" O.C.24'-0"23'-0"5/8" GYP. BD.1-2x8 TREATED8'-4"" POUREDWALL W/ REBARPER CODESILL PLATEWATER PROOFINGAS REQUIREDDRAIN TILE 20x8R-10 RIGID INSUL.20x8POURED WALLRIDGE VENTGRADEDRAIN TILE AS REQUIRED1-2x8 TREATEDSILL PLATE8'-4" POUREDWALL W/ REBARPER CODEWATER PROOFING2" R-10RIGID INSUL.20x8 Planco MN, Inc.C#24-031SMA882024FLOOR SYSTEMROOFTRUSSPVC T-FITTINGTO SUPPORTVENT PIPEMIN. 4" OF GASPERMEABLE MATERIAL3 1/2" CONC. SLAB4" PVC VENT PIPESUPPORTSTRAPPINGFLASHINGEXHAUST 10' FROM OPNGS.INTO CONDITIONED SPACESOF BUILDING12" MIN. ABOVE ROOFSEAL6 MIL POLYUNDER SLAB10' OF DRAIN TILEEACH WAY FROMT-FITTING(ROCK) RADON GAS VENT SYSTEM 3/8" = 1'-0" 36" MIN. HT. CLEAR SPACE24" DIA. AROUND VENTPROVIDE ELECTRICALBOX POWER SOURCER-4 MIN. INSUL. VENT PIPE@ UNCONDITIONED SPACE4" MIN. CLEARANCEFOR FUT. FANMAX. HEIGHT 10' 12' MAX. TOTAL WALL HEIGHT FASTEN KING STUDTO HEADER W/ SIX16d SINKETSFASTEN TOP PLATE TOHEADER W/ TWO ROWSOF 16d SINKER NAILS AT3" O.C. TYP.MIN. 3/8" WOODSTRUCTURALPANEL SHEATHINGMIN. DBL 2x4 POST (KINGAND JACK STUD) NUMBEROF JACK STUDS PERTABLES R602.7(1) AND (2)TYP. PORTAL FRAMECONSTRUCTIONIF NEEDED, PANEL SPLICEEDGES SHALL OCCUR OVERAND BE NAILED TO COMMONBLOCKING WITHIN THE MIDDLE24" OF THE PORTAL-LEGHEIGHT. ONE ROW OF 3" O.C.NAILING REQ'D. IN EACHPANEL EDGEBRACED WALL LINECONTINUOUSLY SHEATHEDW/ WOOD STRUCTURALPANELSEXTENT OF HEADER W/ DOUBLE PORTAL FRAMES(TWO BRACED WALL PANELS)EXTENT OF HEADER W/ SINGLE PORTAL FRAMES(ONE BRACED WALL PANEL)2'-18' FINISHED WIDTH OF OPENINGFOR SINGLE OR DOUBLE PORTALMIN. 3"x11 1/4" NET HEADER - STEEL HEADERPROHIBITED. IF 1/2" SPACER IS USED, PLACEON BACK SIDE OF HEADERFASTEN SHEATHING TO HEADER W/ 8dCOMMON OR GALV. BOX NAILS IN 3"GRID PATTERN AS SHOWN5/8" DIA. ANCHOR BOLTW/ 7" MIN. EMBEDMENTMIN. WIDTH = 16" FOR 1 STORY STRUCTURESMIN. WIDTH = 24" FOR 2 STORY STRUCTURESMIN. DBL. 2x4 FRAMING COVERED W/ MIN.7/16" THICK WOOD STRUCTURAL PANELSHEATHING W/ 8d COMMON OR GALV.BOX NAILS AT 3" O.C. IN ALL FRAMING(STUDS, BLOCKING, SILLS) AS SHOWN TYP.SIMPSON STRONG-TIE LSTA21MIN. 1000 LB. STRAPPONY WALL HEIGHT SIMPSON STRONG-TIE STHD14MIN. 4200 LB. EMBEDDEDTIE-DOWN EACH END OF PANELOPPOSITE SHEATHINGSIMPSON STRONG-TIE LSTA21MIN. 1000 LB. STRAPOPPOSITE SHEATHING1/2" MIN. ENDDISTANCE TYP.OVER CONCRETE OR MASONRY BLOCK FOUNDATION (WHERE PORTAL SHEATHING LAPS OVER BAND OR RIM JOIST)OVER RAISED WOOD FLOOR - OVERLAP OPTION MIN OVERLAP9 1/4"APPROVED BANDOR RIM JOISTNAIL SOLE PLATETO JOIST PERTABLE R602.3(1)ATTACH SHEATHING TOBAND OR RIM JOIST W/8d COMMON NIALS AT 3"O.C. TOP AND BOTTOMWOOD STRUCTURAL PANEL SHEATHING OVERAPPROVED BAND OR RIM JOISTWOOD STRUCTURAL PANELSHEATHING TO OVERLAPBAND OR RIM JOISTNAIL SOLE PLATETO JOIST PERTABLE R602.3(1)FRONT ELEVATIONSECTIONFIGURE R602.10.6.4 SCALE: 3/8" = 1'-0"METHOD CS-PF: CONTINUOUSLY SHEATHED PORTAL FRAME PANEL CONSTRUCTION 6/5/2024 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Signed:___________________________________ Print Name:_______________________________ Date:____________License Number:___________54690 Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS---------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC. 19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070 PH: 281.351.0048 FAX: 281.351.0148 SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE: DRAWING NUMBER:WALL BRACING PLAN17997 HIDDEN CREEK TRAIL, LAKEVILLE, MN 55044BELLEPAR HOMESCB AR TML 1/8" = 1'-0"06/05/2024 WB-1--- 6/5/2024 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Signed:___________________________________ Print Name:_______________________________ Date:____________License Number:___________54690 Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS---------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC. 19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070 PH: 281.351.0048 FAX: 281.351.0148 SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE: DRAWING NUMBER:WALL BRACING PLAN17997 HIDDEN CREEK TRAIL, LAKEVILLE, MN 55044BELLEPAR HOMESCB AR TML 1/8" = 1'-0"06/05/2024 WB-2--- 6/5/2024 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Signed:___________________________________ Print Name:_______________________________ Date:____________License Number:___________54690 Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS---------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC. 19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070 PH: 281.351.0048 FAX: 281.351.0148 SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE: DRAWING NUMBER:WALL BRACING PLAN17997 HIDDEN CREEK TRAIL, LAKEVILLE, MN 55044BELLEPAR HOMESCB AR TML 1/8" = 1'-0"06/05/2024 WB-3--- · · · · · 6/5/2024 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Signed:___________________________________ Print Name:_______________________________ Date:____________License Number:___________54690 Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS---------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC. 19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070 PH: 281.351.0048 FAX: 281.351.0148 SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE: DRAWING NUMBER:WALL BRACING NOTES & DETAILSMINNESOTA 2020 IRC - 115 MPH ULTIMATE 3-SEC GUST 17997 HIDDEN CREEK TRAIL, LAKEVILLE, MN 55044BELLEPAR HOMESTML TML TML 1/8" = 1'-0"06/05/2024 FR-02--- 6/5/2024 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Signed:___________________________________ Print Name:_______________________________ Date:____________License Number:___________54690 Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS---------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC. 19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070 PH: 281.351.0048 FAX: 281.351.0148 SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE: DRAWING NUMBER:WALL BRACING NOTES & DETAILSMINNESOTA 2020 IRC - 115 MPH ULTIMATE 3-SEC GUST 17997 HIDDEN CREEK TRAIL, LAKEVILLE, MN 55044BELLEPAR HOMESTML TML TML 1/8" = 1'-0"06/05/2024 FR-03--- 6/5/2024 I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Signed:___________________________________ Print Name:_______________________________ Date:____________License Number:___________54690 Tim M. Lipasek BYDESCRIPTIONDATEREVISIONS---------------------COPYRIGHT, 2005, DPIS ENGINEERING, LLC.DPIS ENGINEERING,LLC. 19450 STATE HIGHWAY 249HOUSTON, TEXAS 77070 PH: 281.351.0048 FAX: 281.351.0148 SECTION:LOT:BLOCK:UNAUTHORIZED USE OR REPRODUCTION OF THIS DRAWING MAY BE AN INFRINGMENT OF THE FEDERAL COPYRIGHT ACT. THIS DRAWING IS PROTECTED UNDER THE FEDERAL COPYRIGHT ACT BY DPIS ENGINEERING, LLC.DRAWN:DESIGNED:CHECKED:CUSTOMER:SUBDIVISION / ADDRESS:PROJECT TITLE:DRAWING SCALE:ISSUE DATE: DRAWING NUMBER:WALL BRACING NOTES & DETAILSMINNESOTA 2020 IRC - 115 MPH ULTIMATE 3-SEC GUST 17997 HIDDEN CREEK TRAIL, LAKEVILLE, MN 55044BELLEPAR HOMESTML TML TML 1/8" = 1'-0"06/05/2024 FR-03.1--- Mid State Plumbing HVAC Load Calculations for 17997 Hidden Creek TR Prepared By: Tuesday, May 28, 2024 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing Plymouth, MN 55441 Page 2 Project Report General Project Information Project Title:Mid State Plumbing Project Date:Tuesday, May 28, 2024 Client Name:17997 Hidden Creek TR Design Data Reference City:Minneapolis/St. Paul AP, Minnesota Building Orientation:Front door faces East Daily Temperature Range:Medium Latitude:44 Degrees Elevation:834 ft. Altitude Factor:0.970 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter:-15 -15 n/a n/a 72 n/a Summer:88 71 44%50%75 24 Check Figures Total Building Supply CFM:1,006 CFM Per Square ft.:0.313 Square ft. of Room Area:3,212 Square ft. Per Ton:1,423 Volume (ft³):21,922 Building Loads Total Heating Required Including Ventilation Air:48,713 Btuh 48.713 MBH Total Sensible Gain:22,351 Btuh 83 % Total Latent Gain:4,732 Btuh 17 % Total Cooling Required Including Ventilation Air:27,083 Btuh 2.26 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. \\auerfiles\FILES ...\Mid State Plumbing 17997 Hidden Creek TR.rh9 Tuesday, May 28, 2024, 3:37 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing Plymouth, MN 55441 Page 3 Miscellaneous Report System 1 House Input Data Outdoor Dry Bulb Outdoor Wet Bulb Outdoor Rel.Hum Indoor Rel.Hum Indoor Dry Bulb Grains Difference Winter:-15 -15 100%n/a 72 n/a Summer:88 71 44%50%75 23.51 Duct Sizing Inputs Main Trunk Runouts Calculate:Yes Yes Use Schedule:Yes Yes Roughness Factor:0.00300 0.01000 Pressure Drop:0.1000 in.wg./100 ft.0.1000 in.wg./100 ft. Minimum Velocity:0 ft./min 0 ft./min Maximum Velocity:900 ft./min 750 ft./min Minimum Height:0 in.0 in. Maximum Height:0 in.0 in. Outside Air Data Winter Summer Infiltration Specified:0.280 AC/hr 0.150 AC/hr 102 CFM 55 CFM Infiltration Actual:0.280 AC/hr 0.150 AC/hr Above Grade Volume:Cu.ft.Cu.ft.X 21,922 X 21,922 6,138 Cu.ft./hr 3,288 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration:102 CFM 55 CFM Total Building Ventilation:160 CFM 160 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 13.87 = (1.10 X 0.970 X 13.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 15.51 = (0.68 X 0.970 X 23.51 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference) Winter Infiltration Specified:0.280 AC/hr (102 CFM), Construction: Average Summer Infiltration Specified:0.150 AC/hr (55 CFM), Construction: Average \\auerfiles\FILES ...\Mid State Plumbing 17997 Hidden Creek TR.rh9 Tuesday, May 28, 2024, 3:37 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing Plymouth, MN 55441 Page 4 Load Preview Report Scope Net Ton ft.² /Ton Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM Duct Size Building 2.26 1,423 3,212 22,351 4,732 27,083 48,713 573 1,006 1,006 System 1 2.26 1,423 3,212 22,351 4,732 27,083 48,713 573 1,006 1,006 12x15 Ventilation 888 2,482 3,370 5,942 Zone 1 3,212 21,463 2,250 23,713 42,771 573 1,006 1,006 12x15 1-Lower Level 965 3,281 273 3,554 9,647 129 154 154 2--6 2-Main Level 1,030 8,313 586 8,899 15,868 212 389 389 4--7 3-Upper Level 1,217 9,869 1,391 11,260 17,256 231 462 462 5--6 \\auerfiles\FILES ...\Mid State Plumbing 17997 Hidden Creek TR.rh9 Tuesday, May 28, 2024, 3:37 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing Plymouth, MN 55441 Page 5 Duct Size Preview Room or Duct Name Source Minimum Velocity Maximum Velocity Rough. Factor Design L/100 SP Loss Duct Velocity Duct Length Htg Flow Clg Flow Act. Flow Duct Size System 1 Supply Runouts Zone 1 1-Lower Level Built-In 0 750 0.01 0.1 391.4 129 154 154 2--6 2-Main Level Built-In 0 750 0.01 0.1 364.3 212 389 389 4--7 3-Upper Level Built-In 0 750 0.01 0.1 471 231 462 462 5--6 Other Ducts in System 1 Supply Main Trunk Built-In 0 900 0.003 0.1 804.4 573 1,006 1,006 12x15 SummarySummarySummarySummarySummarySummarySummarySummary System 1 Heating Flow:573 Cooling Flow:1006 \\auerfiles\FILES ...\Mid State Plumbing 17997 Hidden Creek TR.rh9 Tuesday, May 28, 2024, 3:37 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing Plymouth, MN 55441 Page 6 Total Building Summary Loads Component Description Area Quan Sen Loss Lat Gain Sen Gain Total Gain Marvin: Glazing-Marvin, U-value 0.34, SHGC 0.32 332.8 9,843 0 10,556 10,556 11P: Door-Metal - Polyurethane Core, U-value 0.29 42 1,060 0 292 292 15B0-10sf-8: Wall-Basement, , R-10 board insulation to floor, no interior finish, 8' floor depth, U-value 0.05 1017 4,746 0 87 87 15B0-10sf-4: Wall-Basement, , R-10 board insulation to floor, no interior finish, 4' floor depth, U-value 0.054 108 508 0 0 0 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud cavity, no board insulation, siding finish, wood studs, U-value 0.065 2370.2 13,403 0 2,049 2,049 16B-50: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-50 insulation, U-value 0.02 1217 2,117 0 1,168 1,168 21B-20: Floor-Basement, Concrete slab, any thickness, 2 or more feet below grade, R-3 or higher insulation installed below floor, any floor cover, shortest side of floor slab is 20' wide, U-value 0.019 964.8 1,595 0 0 0 Subtotals for structure:33,272 0 14,152 14,152 People:7 1,400 1,610 3,010 Equipment:0 3,600 3,600 Lighting:0 0 0 Ductwork:0 0 0 0 Infiltration: Winter CFM: 102, Summer CFM: 55 9,499 850 761 1,611 Ventilation: Winter CFM: 160, Summer CFM: 160 5,942 2,482 888 3,370 Exhaust: Winter CFM: 160, Summer CFM: 160 AED Excursion:0 0 1,340 1,340 Total Building Load Totals:48,713 4,732 22,351 27,083 Check Figures Total Building Supply CFM:1,006 CFM Per Square ft.:0.313 Square ft. of Room Area:3,212 Square ft. Per Ton:1,423 Volume (ft³):21,922 Building Loads Total Heating Required Including Ventilation Air:48,713 Btuh 48.713 MBH Total Sensible Gain:22,351 Btuh 83 % Total Latent Gain:4,732 Btuh 17 % Total Cooling Required Including Ventilation Air:27,083 Btuh 2.26 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. \\auerfiles\FILES ...\Mid State Plumbing 17997 Hidden Creek TR.rh9 Tuesday, May 28, 2024, 3:37 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing Plymouth, MN 55441 Page 7 Building Pie Chart Building Loss 48,713 Btuh Floor 3%Roof 4% Wall 38% Glass 20% Door 2% Infiltration 19% Ventilation 12% Building Gain 27,083 Btuh Roof 4% Wall 8% Glass 39% Door 1% People 11% Equipment 13% Infiltration 6% Ventilation 12% AED Excursion 5% \\auerfiles\FILES ...\Mid State Plumbing 17997 Hidden Creek TR.rh9 Tuesday, May 28, 2024, 3:37 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing Plymouth, MN 55441 Page 8 Detailed Room Loads - Room 1 - Lower Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:32.2 ft.System Number:1 Room Width:30.0 ft.Zone Number:1 Area:964.8 sq.ft.Supply Air:154 CFM Ceiling Height:9.0 ft.Supply Air Changes:1.1 AC/hr Volume:8,683 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:2 Actual Winter Vent.:36 CFM Runout Air:77 CFM Percent of Supply.:23 % Runout Duct Size:6 in.Actual Summer Vent.:24 CFM Runout Air Velocity:391 ft./min.Percent of Supply:16 % Runout Air Velocity:391 ft./min.Actual Winter Infil.:9 CFM Actual Loss:0.096 in.wg./100 ft.Actual Summer Infil.:5 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain E -Wall-15B0-10sf-8 35 X 9 315 0.050 4.7 1,470 0.1 0 27 S -Wall-15B0-10sf-8 20 X 9 180 0.050 4.7 840 0.1 0 15 S -Wall-15B0-10sf-4 15 X 4 60 0.054 4.7 282 0.0 0 0 S -Wall-12F-0sw 15 X 5 54 0.065 5.7 305 0.9 0 47 W -Wall-15B0-10sf-4 12 X 4 48 0.054 4.7 226 0.0 0 0 W -Wall-12F-0sw 12 X 5 30.2 0.065 5.7 171 0.9 0 26 W -Wall-15B0-10sf-8 23 X 9 207 0.050 4.7 966 0.1 0 18 N -Wall-15B0-10sf-8 35 X 9 315 0.050 4.7 1,470 0.1 0 27 S -Gls-Marvin shgc-0.32 0%S 21 0.340 29.6 621 19.0 0 399 W -Gls-Marvin shgc-0.32 0%S 21 0.340 29.6 621 34.3 0 721 W -Gls-Marvin shgc-0.32 0%S 8.8 0.340 29.6 259 34.3 0 300 Floor-21B-20 30 X 32.2 964.8 0.019 1.7 1,595 0.0 0 0 Subtotals for Structure:8,826 0 1,580 Infil.: Win.: 8.8, Sum.: 4.7 247 3.326 821 0.267 73 66 AED Excursion:205 People: 200 lat/per, 230 sen/per:1 200 230 Equipment:0 1,200 Room Totals:9,647 273 3,281 \\auerfiles\FILES ...\Mid State Plumbing 17997 Hidden Creek TR.rh9 Tuesday, May 28, 2024, 3:37 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing Plymouth, MN 55441 Page 9 Detailed Room Loads - Room 2 - Main Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:32.2 ft.System Number:1 Room Width:32.0 ft.Zone Number:1 Area:1,029.8 sq.ft.Supply Air:389 CFM Ceiling Height:9.0 ft.Supply Air Changes:2.5 AC/hr Volume:9,268 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:4 Actual Winter Vent.:59 CFM Runout Air:97 CFM Percent of Supply.:15 % Runout Duct Size:7 in.Actual Summer Vent.:62 CFM Runout Air Velocity:364 ft./min.Percent of Supply:16 % Runout Air Velocity:364 ft./min.Actual Winter Infil.:46 CFM Actual Loss:0.068 in.wg./100 ft.Actual Summer Infil.:25 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain E -Wall-12F-0sw 36 X 9 249 0.065 5.7 1,408 0.9 0 215 S -Wall-12F-0sw 36 X 9 316 0.065 5.7 1,787 0.9 0 273 W -Wall-12F-0sw 36 X 9 222.5 0.065 5.7 1,258 0.9 0 192 N -Wall-12F-0sw 36 X 9 324 0.065 5.7 1,832 0.9 0 280 E -Door-11P 3 X 7 21 0.290 25.2 530 7.0 0 146 E -Door-11P 3 X 7 21 0.290 25.2 530 7.0 0 146 E -Gls-Marvin shgc-0.32 0%S (2)33 0.340 29.6 976 34.3 0 1,132 S -Gls-Marvin shgc-0.32 0%S (2)8 0.340 29.6 236 19.0 0 152 W -Gls-Marvin shgc-0.32 0%S (3)49.5 0.340 29.6 1,464 34.3 0 1,698 W -Gls-Marvin shgc-0.32 0%S 42 0.340 29.6 1,242 34.3 0 1,442 W -Gls-Marvin shgc-0.32 0%S 10 0.340 29.6 296 34.3 0 343 Subtotals for Structure:11,559 0 6,019 Infil.: Win.: 46.4, Sum.: 24.9 1,296 3.325 4,309 0.266 386 345 AED Excursion:519 People: 200 lat/per, 230 sen/per:1 200 230 Equipment:0 1,200 Room Totals:15,868 586 8,313 \\auerfiles\FILES ...\Mid State Plumbing 17997 Hidden Creek TR.rh9 Tuesday, May 28, 2024, 3:37 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing Plymouth, MN 55441 Page 10 Detailed Room Loads - Room 3 - Upper Level (Average Load Procedure) General Calculation Mode:Htg. & clg.Occurrences:1 Room Length:34.8 ft.System Number:1 Room Width:35.0 ft.Zone Number:1 Area:1,217.0 sq.ft.Supply Air:462 CFM Ceiling Height:9.0 ft.Supply Air Changes:2.5 AC/hr Volume:10,953 cu.ft.Req. Vent. Clg:0 CFM Number of Registers:5 Actual Winter Vent.:65 CFM Runout Air:92 CFM Percent of Supply.:14 % Runout Duct Size:6 in.Actual Summer Vent.:74 CFM Runout Air Velocity:471 ft./min.Percent of Supply:16 % Runout Air Velocity:471 ft./min.Actual Winter Infil.:47 CFM Actual Loss:0.138 in.wg./100 ft.Actual Summer Infil.:25 CFM Item Description Area Quantity -U- Value Htg HTM Sen Loss Clg HTM Lat Gain Sen Gain E -Wall-12F-0sw 36 X 9 268 0.065 5.7 1,516 0.9 0 232 S -Wall-12F-0sw 37 X 9 318 0.065 5.7 1,798 0.9 0 275 W -Wall-12F-0sw 36 X 9 263.5 0.065 5.7 1,490 0.9 0 228 N -Wall-12F-0sw 37 X 9 325 0.065 5.7 1,838 0.9 0 281 E -Gls-Marvin shgc-0.32 0%S 10 0.340 29.6 296 34.3 0 343 E -Gls-Marvin shgc-0.32 0%S (2)42 0.340 29.6 1,242 34.3 0 1,442 E -Gls-Marvin shgc-0.32 0%S 4 0.340 29.6 118 34.3 0 137 S -Gls-Marvin shgc-0.32 0%S 15 0.340 29.6 444 19.0 0 285 W -Gls-Marvin shgc-0.32 0%S (3)52.5 0.340 29.6 1,554 34.3 0 1,803 W -Gls-Marvin shgc-0.32 0%S 8 0.340 29.6 237 34.4 0 275 N -Gls-Marvin shgc-0.32 100%S 8 0.340 29.6 237 10.5 0 84 UP-Ceil-16B-50 34.8 X 35 1217 0.020 1.7 2,117 1.0 0 1,168 Subtotals for Structure:12,887 0 6,553 Infil.: Win.: 47.1, Sum.: 25.2 1,314 3.325 4,369 0.266 391 350 AED Excursion:616 People: 200 lat/per, 230 sen/per:5 1,000 1,150 Equipment:0 1,200 Room Totals:17,256 1,391 9,869 \\auerfiles\FILES ...\Mid State Plumbing 17997 Hidden Creek TR.rh9 Tuesday, May 28, 2024, 3:37 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Auer Steel (Plymouth)Mid State Plumbing Plymouth, MN 55441 Page 11 System 1 Room Load Summary No Room Name Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM ---Zone 1--- 1 Lower Level 965 9,647 129 2-6 391 3,281 273 154 154 2 Main Level 1,030 15,868 212 4-7 364 8,313 586 389 389 3 Upper Level 1,217 17,256 231 5-6 471 9,869 1,391 462 462 Ventilation 5,942 888 2,482 System 1 total 3,212 48,713 573 22,351 4,732 1,006 1,006 System 1 Main Trunk Size:12x15 in. Velocity:804 ft./min Loss per 100 ft.:0.097 in.wg Cooling System Summary Cooling Tons Sensible/Latent Split Sensible Btuh Latent Btuh Total Btuh Net Required:2.26 83% / 17%22,351 4,732 27,083 Equipment Data Heating System Cooling System Type:Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency:0 AFUE 0 SEER Sound:0 0 Capacity:0 Btuh 0 Btuh Sensible Capacity:n/a 0 Btuh Latent Capacity:n/a 0 Btuh \\auerfiles\FILES ...\Mid State Plumbing 17997 Hidden Creek TR.rh9 Tuesday, May 28, 2024, 3:37 PM Date Certificate PostedX Passive (No Fan)Active (With fan and monometer or other system monitoring device)xR-15 x R-15 x R-20 x R-20 x R-21 x R-49 x R-49 x R-30+ x R-30+ x x X Not applicable, all ducts located in conditioned space MECHANICAL SYSTEMS X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: 80k Capacity in Gallons:XAldes air Exchanger E150 Heat Loss:48,713 Cfm's " round duct OR " metal duct Not required per mech. code X Passive Low: Other, describe: x 75 Location of fan(s), describe: Cfm's X " round duct OR " metal duct Total ventilation (intermittent + continuous) rate in cfms: Continuous exhausting fan(s) rated capacity in cfms: High: High: Mechanical Ventilation System 150/75 Bradford White Rating or Size Structure's Calculated SEER: Efficiency AFUE or HSPF% Heat Gain: Amana Manufacturer Amana Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 13 Calculated cooling load: Basement and Duct in Floor trusses Combustion Air Select a Type 27,083 MITW50 ASX13 Capacity continuous ventilation rate in cfms: Mechanical room in Garage Speed 150 Select Type Model AMES96 50 Output in Tons: 3T Location of duct or system: 6 " 0 96.00% Variable Appliances Cooling System 0.30 0.30 Interior Natural Gas Electric Heating or Cooling Ducts Outside Conditioned Spaces Exterior & Interior Domestic Water Heater R-value, R-8 Make-up Air Select a Type Average U-Factor (excludes skylights and one door ) U: Heating System Natural Gas RADON SYSTEM Rim Joist (1 st Floor+) Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Bonus room over garage Describe other insulated areasMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateTHERMAL ENVELOPE Insulation LocationFoam, Closed CellFoam Open CellAttic Exterior 2" CertiStud -- Interior 3/4" Thermax Interior Wall Ceiling, flat Other Please Describe HereTotal R-Value of all Types of InsulationType: Check All That ApplyNon or Not ApplicableFiberglass, BlownFiberglass, Batts Below Entire Slab Foundation Wall Perimeter of Slab on Grade Rim Joist (Foundation) Per N1101.8 Building Certificate. A building certificate shall be posted in a permanently visible location inside the building. The certificate shall be completed by the builder and shall list information and values of components listed in Table N1101.8.6/11/24 Place your logo here New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit 17997 Hidden Creek Tr Created by BAM version 052009 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is required for “Construction activity that results in land disturbance of equal to or greater than one (1) acre or if a project is part of a common plan of development that will ultimately disturb greater than one (1) acre,” (NPDES Permit, Section 1.2). Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ *Primary Company Contact: _________________________________________________________________ *Should a site be deemed noncompliant, this individual will be notified Phone #: ____________________________ Email: ______________________________________________ If you are not covered under a NPDES Construction Stormwater Permit administered by the Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be approved as part of the residential building permit application. “Permittees must ensure a trained person will inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than ½ inch in 24 hours,” (NPDES Permit, Section 11.2). The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name: ____________________________________ Company: ___________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: __________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001). Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 17997 Hidden Creek Trail Bellepar Homes Brian Gergen 612-369-1723 briang@belleparhomes.com Brian L Gergen Bellepar Homes briang@belleparhomes.com U of M May 31, 2026 6.12.24 6/14/24 X PM