Loading...
HomeMy WebLinkAboutLA225279 - 17749 Emerald Ct-Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -6 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"VINYL SHAKES TYP.6" SMARTSIDE FRIEZE BOARDTYP. @ FRONTVINYL LAP SIDING @ FRONT TYP.CULTURED STONEW/ CONCRETE CAPALUMINUM SOFFIT& FASCIA TYP.6" SMARTSIDE TRIM @ FRONTTYP.SEE COLUMN DETAILDETAIL SHEET A-501ADDRESS STONE4" SMARTSIDE TRIM @ WINDOWS & DOORSTYP. @ FRONTGARAGE PLATE HEIGHT10' - 9 3/8"6" SMARTSIDE STORYBOARD8" 12"VINYL BOARD& BATTEN TYP.7" / 12"3' - 6"5' - 0"7" / 12"3' - 6"TOP ROW GLASS TOP ROW GLASS ARCHED TRIMARCHED TRIMDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/26/2024 11:17:53 AMTHE PETERSON RESIDENCEL37, B3 - PHEASANT RUN 7TH ADD'N17749 EMERALD COURTLAKEVILLE, MN 55044A-201OTT4575.29.24 CB175212779255.23.24 CB8'- 1 1/8"9'- 1 1/8"8'-4" POUR3954MAVERICK MODEL1/4" = 1'-0"A-2011FRONT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONA-202 ELEVATIONS/ ROOF PLANA-401 FOUNDATIONA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 SECTIONS - SCHEDULESA-502 DETAILSA-503 DETAILSConcept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode07/08/2024jnuetzman 24" RETURNS TYP.8" / 12"8" / 12"7" 12"24" RETURNS TYP.7" 12"8" / 12"8" / 12"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING &CORNERS @ SIDES & REAR7" / 12"8" 12"8" 12"18" OVERHANGS & 12" RAKES TYP.STANDARD ENERGY HEELS @ 8:128 ROOF VENTS REQUIRED 1 ROOF VENT REQUIRED 2 ROOF VENTSREQUIRED@ GARAGE 8" / 12"8" / 12"8" / 12"8" / 12"7" / 12"STANDARD ENERGY HEELS @ 7:127" / 12"7" / 12"DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/26/2024 11:17:56 AMTHE PETERSON RESIDENCEL37, B3 - PHEASANT RUN 7TH ADD'N17749 EMERALD COURTLAKEVILLE, MN 55044A-202OTT4575.29.24 CB175212779255.23.24 CB8'- 1 1/8"9'- 1 1/8"8'-4" POUR3954MAVERICK MODEL1/8" = 1'-0"A-2021RIGHT ELEVATION1/8" = 1'-0"A-2022LEFT ELEVATION1/8" = 1'-0"A-2023REAR ELEVATION1/8" = 1'-0"A-2024ROOF PLANSecure door closed until deck isconstructed with a separate permit. 11' - 10"2' - 0"0' - 2"18' - 10"36' - 0"3' - 4 1/2"10' - 3" M.O.2' - 9"16' - 3" M.O.3' - 4 1/2"10' - 0"15' - 0"17' - 0"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"0' - 4"2" FOAM INSULATIONBETWEEN WALL & SLAB11' - 8"8' - 0"21' - 6"6' - 0"50' - 0"42' - 2"7' - 10"2' - 0"5' - 10"36' - 2"6' - 0"19' - 8"15' - 9 1/4"4' - 2 3/4"4' - 2 3/4"11' - 11 1/4"4' - 7"7' - 2"7' - 4 1/2"22' - 10 1/2"22' - 4"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.ALL DIMENSIONS ARETO EXTERIOR OF CONCRETE, NOT INSULATION22' - 6"27' - 6"50' - 0"3' - 9"6' - 1":LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE9' - 10"8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.ANCHOR BOLTS ON EACH SIDEOF BEARING POINT TYPICAL 12' - 10"42' - 0"8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY54' - 10"LEAVE A 12" GAP IN THE FOOTING FOR PLUMBING22' - 4":LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.54' - 10"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY13' - 10"7' - 1 1/2"12' - 6 1/2"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.36" x 36" x 12" CONCRETE FTG.W/ (3) #5 REBAR EACH WAY3' - 9 1/4"13' - 2 3/4"DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/26/2024 11:17:57 AMTHE PETERSON RESIDENCEL37, B3 - PHEASANT RUN 7TH ADD'N17749 EMERALD COURTLAKEVILLE, MN 55044A-401OTT4575.29.24 CB175212779255.23.24 CB8'- 1 1/8"9'- 1 1/8"8'-4" POUR3954MAVERICK MODEL1/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. UNEXCAVATEDFURNACESUMPW. H.F. D.BATHMECHANICAL/STORAGE11' - 10"2' - 0"0' - 2"18' - 10"36' - 0"42' - 2"7' - 10"3' - 4 1/2"10' - 3" M.O.2' - 9"16' - 3" M.O.3' - 4 1/2"2' - 0"5' - 10"36' - 2"6' - 0"12' - 2"4' - 0"4' - 0"16' - 0"UNEXCAVATED10' - 0"15' - 0"17' - 0"22' - 6"27' - 6"6' - 0"21' - 6"12/4 x 6/8R.O. 2' -6" x 6' -11"62/8 x 6/8R.O. 2' -10" x 6' -11"SET SILL 6" ABOVE TRT'D PLATE20' - 0"16' - 2"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.5' - 0"5' - 10"8' - 10"2-14" FLUSH LVL24" CANT. ABOVE0' - 4"0' - 4"* ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE/ SHEATHING,NOT INSULATION2" FOAM INSULATIONBETWEEN WALL & SLABBEDROOM #518' - 10 3/4"10' - 1 1/4"2' - 1"10' - 11"4' VANITY2x6CO DET.SMOKEDET.CO DET.FAMILY ROOM6' - 8"4' - 2"KNEE WALL W/ PAINTED SPINDLESFLOOR GIRDER2-2x102-2x1022' - 4"11' - 8"8' - 0"19' - 8"50' - 0"50' - 0"2-2x109' - 10"AIR EX.2-2x10 FLUSH22' - 4"18" FLOOR TRUSSESPER MFG. SPACING18" FLOOR TRUSSESPER MFG. SPACING42' - 0"12' - 10"54' - 10"4-2x64-2x674036 NVPWG TEMP.R.O. 4' -0" x 3' -6"H.H. 2' -5 1/4"9' - 0"8' - 0"7' - 6"7' - 6"4' - 3"5' - 9"138040E NVGER.O. 8' -0" x 4' -0"H.H. 6' -10"105040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"CS-WSP3' - 3" B.W.PCS-WSP2' - 8" B.W.PCS-WSP2' - 8" B.W.PCS-WSP5' - 0" B.W.PCS-WSP4' - 0" B.W.P2-9 1/2" LSL W/3 TRIMMERS ES. SIDE 2-11 7/8" LSL W/3 TRIMMERS ES. SIDE 2-9 1/2" LSL48" F.G. SHWR42/6 x 6/8R.O. 2' -8" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"CLOSET #5SMOKEDET.R & SH. @ 65"2' LINENROUGH-IN FOR FUTURE WET BAR 54' - 10"13' - 10"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES136/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"ANCHOR BOLTS ON EACH SIDEOF BEARING POINT TYPICAL 3' - 2"STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.1/4" = 1'-0"A-4021LOWER FLOOR PLANDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/26/2024 11:17:58 AMTHE PETERSON RESIDENCEL37, B3 - PHEASANT RUN 7TH ADD'N17749 EMERALD COURTLAKEVILLE, MN 55044A-402OTT4575.29.24 CB175212779255.23.24 CB8'- 1 1/8"9'- 1 1/8"8'-4" POUR3954MAVERICK MODELFAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). 42' - 0"8' - 0"42' - 0"12' - 10"36" REFKITCHENDINING ROOMGREAT ROOMBOX VAULTFOYERSINKDWPORCH6' - 0"36' - 0"6' - 0"2' - 0"114/0 x 6/8 FULL VIEWR.O. 4' -2" x 6' -11"18' - 10"36' - 0"11' - 6"7' - 4"3' - 6"16' - 0"3' - 0"10' - 0"3' - 6"1' - 0"9' - 6"1' - 0"1516' x 8' O.H. GARAGE DOORTYP.0' - 4 1/2"POWDER16" SH.103/0 x 6/8 W/ 12" SL'S STEEL4' - 0"8' - 0"2' - 0"14' - 0"5' - 9"5' - 9"3' - 7"4' - 3"50' - 0"50' - 0"6' - 0"21' - 6"17' - 0"15' - 0"10' - 0"22' - 0"3' VANITY32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"GARAGE2' - 0"20' - 8"12/4 x 6/8R.O. 2' -6" x 6' -11"R & SH. @ 65"4' - 0"4' - 6"32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"KNEE WALL W/ PAINTED SPINDLESRECYCLE@ 6' -10" H.H.ABOVE LANDING16' - 0"6' - 4 1/4"11' - 3 1/4"2' - 4 1/2"2' - 7"3' - 5"DOUBLE FRAMEDWALL FORREF RECESS 39"x73"U.C. LIGHT9' - 0"8' - 0"7' - 6"7' - 6"2' - 3"7' - 9"13' - 6"5' - 3"3' - 3"12' - 0"4' - 0"4' - 0"16' - 0"5' - 0"6' - 8"7' - 8"5' - 0"5' - 10"0' - 10"30' - 4"6' - 9"5' - 0"3' - 6"6' - 9"GIRDER TRUSSGIRDER TRUSSFLOORGIRDERSEE COLUMN DETAILSHEET A-5012-2x10 CONT.2-2x102-14" LVL FLUSH2-9 1/2"LSL FLUSH2-11 7/8" LSL2-2x102-2x10 DROPPED 2-7 1/4" LSL CONTINUOUS DROPPED2-2x10 W/2 TRIMMERS3-2x6STAGGEREDUPPERS7' - 10"3-16 LVL 2' - 7"3' - 5"END PANELOVEN /MICRO9' - 6"4' - 1 3/4"3' - 6"5' - 6"83/0 x 6/8 FULL VIEWR.O. 3' -1" x 6' -8"EQEQ2' - 0"MECHANICALCHASE 2-2x102-2x12 CONT.2-2x102-2x102-2x10ATTICACCESSCS-WSP6' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP4' - 0" B.W.P.CS-WSP8' - 0" B.W.P.CS-WSP2' - 9" B.W.P.5x5 PSL4-2x6CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.WALL ABOVE BEARING ONFLOOR TRUSSES3-2x62-2x102-2x102' - 0"4-2x62' - 10"3' - 8"2' - 6"36" GAS COOKTOP W/WOOD HOODABOVE12" SH.2-2x10 FLUSHCS-WSP2' - 8" B.W.P.22' - 6"27' - 6"FLOOR GIRDER10' - 0"CS-WSP4' - 0" B.W.P.R & SH. @ 65"12/4 x 6/8R.O. 2' -6" x 6' -11"U.C. LIGHTU.C. LIGHT72/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"20" FLOOR TRUSSESPER MFG. SPACING5' - 10"5' - 0"20" FLOOR TRUSSESPER MFG. SPACING13' - 0"16' - 2"4' - 6"20" FLOOR TRUSSESPER MFG. SPACINGMFG. ROOF TRUSSES@ 24" O.C.CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESHHUS4105x5 PSL5594050E NVG1R.O. 4' -0" x 5' -0"H.H. 6' -10"55594050E NVG1R.O. 4' -0" x 5' -0"H.H. 6' -10"22020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"22020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"126050E NVG1R.O. 6' -0" x 5' -0"H.H. 6' -10"84040 NVPWG TEMP.R.O. 4' -0" x 4' -0"H.H. 11' -11 1/8"12016 NVPWGR.O. 2' -0" x 1' -6"H.H. 8' -0"12016 NVPWGR.O. 2' -0" x 1' -6"H.H. 8' -0"PANTRY53650 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 7' -0"H.H. 8' -0"93/0 x 6/8 OPG.30" PANTRYMUD RM.12/4 x 6/8R.O. 2' -6" x 6' -11"R & SH. @ 65"13' - 0"BUILT-INBUILT-IN78" ELECTRIC FIREPLACE SET 18" OFF FLOOR-STONE TO CEILING- 1410' x 8' O.H. GARAGE DOOR2-9 1/2" LSL FLUSH2-14" LVL FLUSH 54' - 10"54' - 10"1' - 0"5' - 0"HHUS410TAPERED END CUT ALLOWED 2-2x10 W/2 TRIMMERSCS-WSP2' - 3" B.W.P.CS-PF1' - 6" B.W.P.CS-PF1' - 6" B.W.P.OFFICE1' - 6"7' - 6"CS-WSP8' - 0" B.W.P.PFH3' - 6"PFH3' - 6"PFH3' - 0"CS-WSP4' - 0" B.W.P.CS-WSP4' - 0" B.W.P.4" CONCRETE SLAB, SLOPETOWARDS DRAINS5/8" TYPE X GYP. BD. CEILING1/2" GYP. B.D. ON GARAGE WALLS R-38 MIN. INSULATION IN FLOOR ABOVEGARAGE PLATE HEIGHT TO MATCHMAIN FLOOR UNLESS NOTED OTHERWISECS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 9" B.W.P.2-9 1/2" LVL FLUSH 2-2x10 W/2 TRIMMERS 22' - 8"19' - 4"1/4" = 1'-0"A-4031MAIN FLOOR PLANDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/26/2024 11:17:59 AMTHE PETERSON RESIDENCEL37, B3 - PHEASANT RUN 7TH ADD'N17749 EMERALD COURTLAKEVILLE, MN 55044A-403OTT4575.29.24 CB175212779255.23.24 CB8'- 1 1/8"9'- 1 1/8"8'-4" POUR3954MAVERICK MODEL-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).FANVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.BWPsAboveBWPsAbove BEDROOM #4BATHBEDROOM #3PRIMARY SUITEBOX VAULTHALLPRIMARY BATH7'-6" VANITYCLOSETR & SH. @ 65"BEDROOM #215' - 6"9' - 0"17' - 6"17' - 0"15' - 0"10' - 0"42' - 0"42' - 0"32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"42/6 x 6/8R.O. 2' -8" x 6' -11"2' LINEN3' VANITY3' VANITY42/6 x 6/8R.O. 2' -8" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"62/8 x 6/8R.O. 2' -10" x 6' -11"LAUNDRYCLOSETCLOSET #1TILESHOWER42" WALL W/GLASS PANEL ABOVE7' - 9"7' - 9"4' - 6"4' - 6"8' - 9"8' - 9"20' - 0"20' - 0"CONTROLS5' - 6"7' - 1"4' - 5"7' - 6"7' - 6"40' - 0"6' - 0"11' - 0 1/4"28' - 11 3/4"16' - 0"4' - 0"4' - 0"16' - 0"5' - 0"5' - 0"1' - 8"30' - 4"10' - 8"5' - 2"1' - 6 1/4"4' - 0"3' - 11 3/4"6' - 3 3/4"10' - 4 1/4"9' - 7"5' - 6 3/4"9' - 8 1/2"3' - 7 3/4"8' - 1"5' - 5"13' - 7"2' - 6"3' - 8"3' - 0"3' - 3"5' - 4"2' - 8"12' - 0"7' - 10"2' - 4 1/4"6' - 0"9' - 1 3/4"R & SH. @ 65"CO DET.SMOKEDET.SMOKEDET.SMOKEDET.SMOKEDET.ATTICACCESS2-2x102-9 1/2" LSLW/ 2 TRIMMERS2-2x6 EA. SIDEKNEE WALL W/ PAINTED SPINDLESR & SH. @ 48"22/4 x 6/8 OPG.52/6 x 6/8 PKTR.O. 5' -2" x 6' -11"3' VANITY48" F.G. SHWR42/6 x 6/8R.O. 2' -8" x 6' -11"2x6BATHTYP.2' - 0"2-2x102-2x102-2x102-2x1062/8 x 6/8R.O. 2' -10" x 6' -11"R & SH. @ 65"SMOKEDET.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP3' - 0" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.2-2x10 W/ 2 TRIMMERS 2' - 0"3' - 3"MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.6' - 0"40' - 0"46' - 0"46' - 0"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES105040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"148050E NVGER.O. 8' -0" x 5' -0"H.H. 6' -10"64020 NVFA1 TEMP.R.O. 4' -0" x 2' -0"H.H. 6' -10"148050E NVGER.O. 8' -0" x 5' -0"H.H. 6' -10"32036 NVC1R.O. 2' -0" x 3' -6"H.H. 6' -10"116020 NVFA3R.O. 6' -0" x 2' -0"H.H. 6' -10"52/6 x 6/8 PKTR.O. 5' -2" x 6' -11"42/6 x 6/8R.O. 2' -8" x 6' -11"2' - 4"2' - 3"2' - 7"2' - 0"6' - 0"32/4 x 6/8 PKTR.O. 4' -10" x 6' -11"DRYERWASHERSINK2' - 8"CURBHEAD2x6DOUBLE FRAME PLUMBING WALLACCENT WALLCLOSET#212/4 x 6/8R.O. 2' -6" x 6' -11"2' LINEN22020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"6' FREESTANDING TUBWAINSCOTING SURROUND TUB 148050E NVGER.O. 8' -0" x 5' -0"H.H. 6' -10"126/0 x 6/8R.O. 6' -2" x 6' -11"5' - 8"7' - 8"2' - 8"1'-6" LINEN2-2x103' - 3"3' - 11 3/4"CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.CS-WSP2' - 8" B.W.P.5' TUB/SHWRCORNER SEAT(2) SHAMPOO SHELVES 12"x20" RECESSEDNICHE UNDER HEAD2x6SOUNDINSULATION2x6DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/26/2024 11:18:00 AMTHE PETERSON RESIDENCEL37, B3 - PHEASANT RUN 7TH ADD'N17749 EMERALD COURTLAKEVILLE, MN 55044A-404OTT4575.29.24 CB175212779255.23.24 CB8'- 1 1/8"9'- 1 1/8"8'-4" POUR3954MAVERICK MODEL1/4" = 1'-0"A-4041UPPER FLOOR PLANTemper ifwithin 60"of tub floorFANFANFANFAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). WATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER FLOOR PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATIONALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSS1' - 6"2x4 TYP.2x4 @ TOPSOFFITFRONTSIDETOP VIEWSMOOTHSMARTSIDETYPICAL4x4 POSTFRAMING1' - 6"1' - 6"1' - 6"1' - 3"1' - 3"1' - 8"1' - 8"3' - 6"DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/26/2024 11:18:01 AMTHE PETERSON RESIDENCEL37, B3 - PHEASANT RUN 7TH ADD'N17749 EMERALD COURTLAKEVILLE, MN 55044A-501OTT4575.29.24 CB175212779255.23.24 CB8'- 1 1/8"9'- 1 1/8"8'-4" POUR3954MAVERICK MODELWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 VECTOR ENVISION SERIES 2 2016 NVPWG 2' - 0" 1' - 6" 8' - 0"2 VECTOR ENVISION SERIES 3 2020 NVA1 2' - 0" 2' - 0" 6' - 10"3 VECTOR ENVISION SERIES 1 2036 NVC1 2' - 0" 3' - 6" 6' - 10"4 VECTOR ENVISION SERIES 1 2036 NVPWG 2' - 0" 3' - 6" 9' - 8 19/32"5 VECTOR ENVISION SERIES 6 3650 NVPWG/3620 NVA1 TEMP. 3' - 6" 7' - 0" 8' - 0"6 VECTOR ENVISION SERIES 1 4020 NVFA1 TEMP. 4' - 0" 2' - 0" 6' - 10"7 VECTOR ENVISION SERIES 1 4036 NVPWG TEMP. 4' - 0" 3' - 6" 2' - 5 1/4"8 VECTOR ENVISION SERIES 1 4040 NVPWG TEMP. 4' - 0" 4' - 0" 11' - 11 1/8"9 VECTOR ENVISION SERIES 2 4050E NVG1 4' - 0" 5' - 0" 6' - 10"10 VECTOR ENVISION SERIES 2 5040E NVG1 5' - 0" 4' - 0" 6' - 10"11 VECTOR ENVISION SERIES 1 6020 NVFA3 6' - 0" 2' - 0" 6' - 10"12 VECTOR ENVISION SERIES 1 6050E NVG1 6' - 0" 5' - 0" 6' - 10"13 VECTOR ENVISION SERIES 1 8040E NVGE 8' - 0" 4' - 0" 6' - 10"14 VECTOR ENVISION SERIES 3 8050E NVGE 8' - 0" 5' - 0" 6' - 10"3/8" = 1'-0"A-5012TYP. POURED WALL SECTION1/2" = 1'-0"A-5013GARAGE CEILINGROOM FINISHED SCHEDULEFLOOR ROOM NAME FLOORING AREA CEILING HEIGHT COMMENTSLOWER FLOOR MECHANICAL /STORAGE . 218 SF 8' - 2" MECHANICALS MY VARYLOWER FLOOR BEDROOM #5 CARPET 175 SF 8' - 2" .LOWER FLOOR FAMILY ROOM CARPET 538 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 76 SF 8' - 2"LOWER FLOOR CLOSET #5 CARPET 56 SF 8' - 2"LOWER FLOOR BATH VINYL 52 SF 8' - 2" .MAIN FLOOR GARAGE 745 SF 10' - 9 3/8" FINISH PER CODEMAIN FLOOR OFFICE CARPET 114 SF 9' - 1 1/8"MAIN FLOOR STAIRS CARPET 83 SF 9' - 1 1/8"MAIN FLOOR PORCH CONCRETE 128 SF 9' - 1 1/8" .MAIN FLOOR MUD RM. VINYL 76 SF 9' - 1 1/8" .MAIN FLOOR POWDER VINYL 24 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 267 SF 9' - 1 1/8" .MAIN FLOOR DINING ROOM WOOD 183 SF 9' - 1 1/8" .MAIN FLOOR GREAT ROOM WOOD 234 SF 9' - 1 1/8" 8" BOX VAULT W/ WOODMAIN FLOOR FOYER WOOD 131 SF 9' - 1 1/8" .MAIN FLOOR PANTRY WOOD 30 SF 9' - 1 1/8" .UPPER FLOOR BEDROOM #4 CARPET 196 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 212 SF 8' - 1 1/8" .UPPER FLOOR PRIMARY SUITE CARPET 241 SF 8' - 1 1/8" 12" BOX VAULTUPPER FLOOR HALL CARPET 140 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #2 CARPET 157 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 27 SF 8' - 1 1/8" .UPPER FLOOR CLOSET CARPET 21 SF 8' - 1 1/8" .UPPER FLOOR CLOSET #1 CARPET 67 SF 8' - 1 1/8" .UPPER FLOOR CLOSET#2 CARPET 37 SF 8' - 1 1/8"UPPER FLOOR LAUNDRY LVT 59 SF 8' - 1 1/8" .UPPER FLOOR PRIMARY BATH TILE 166 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 110 SF 8' - 1 1/8" .UPPER FLOOR BATH VINYL 50 SF 8' - 1 1/8" .DOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 2/4 x 6/8 2' - 6" 6' - 11" 92 2/4 x 6/8 OPG. 13 2/4 x 6/8 PKT 4' - 10" 6' - 11" 44 2/6 x 6/8 2' - 8" 6' - 11" 55 2/6 x 6/8 PKT 5' - 2" 6' - 11" 26 2/8 x 6/8 2' - 10" 6' - 11" 37 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 18 3/0 x 6/8 FULL VIEW 3' - 1" 6' - 8" 19 3/0 x 6/8 OPG. 110 3/0 x 6/8 W/ 12" SL'S STEEL 111 4/0 x 6/8 FULL VIEW 4' - 2" 6' - 11" 112 6/0 x 6/8 6' - 2" 6' - 11" 113 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 114 10' x 8' O.H. GARAGE DOOR 115 16' x 8' O.H. GARAGE DOOR 11/2" = 1'-0"A-5011TYP. COLUMN 6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2' GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANS0' - 8"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/26/2024 11:18:02 AMTHE PETERSON RESIDENCEL37, B3 - PHEASANT RUN 7TH ADD'N17749 EMERALD COURTLAKEVILLE, MN 55044A-502OTT4575.29.24 CB175212779255.23.24 CB8'- 1 1/8"9'- 1 1/8"8'-4" POUR3954MAVERICK MODEL1/2" = 1'-0"A-5021TYP. POURED WALKOUT SECTION1/2" = 1'-0"A-5022TYP. POURED LOOKOUT SECTION1/2" = 1'-0"A-5023TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5026BEARING WALL SECTION1/2" = 1'-0"A-5027TYP. HOUSE/STOOP WALL3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM: FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP. FASTENKING STUD TO HEADERW/ 6-16d SINKERS.MIN. 7/16" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).FRONT ELEVATIONMIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 7/16" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INFRAMING (STUDS AND SILLS) AS SHOWN TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALEXTENT OF HEADER WITH DOUBLE PORTAL FRAMES (TWO BRACED WALL PANELS)BRACED WALL LINECONTINUOUSLYSHEATHED WITH WOODSTRUCTURAL PANELS.OVERLAP0' - 9 1/4" MIN.WOOD STRUCTURAL PANEL SHEATHINGCONTINUOUS OVER BAND OR RIM JOISTNAIL SOLE PLATE TO JOISTPER TABLE R602.3(1)WOOD STRUCTURAL PANEL SHEATHING OVER APPROVED BAND OR RIM JOISTATTACH SHEATHING TOBAND OR RIM JOIST WITH8d COMMON NAILS @3" O.C. TOP @ BOTTOMFASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED10' - 0" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/26/2024 11:18:03 AMTHE PETERSON RESIDENCEL37, B3 - PHEASANT RUN 7TH ADD'N17749 EMERALD COURTLAKEVILLE, MN 55044A-503OTT4575.29.24 CB175212779255.23.24 CB8'- 1 1/8"9'- 1 1/8"8'-4" POUR3954MAVERICK MODEL3/8" = 1'-0"A-5031METHOD CS-PF3/8" = 1'-0"A-5032METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS STAIRWAYHEADER BYOTHERSSEE DOCUMENTPROVIDED FORATTACHMENT OF F19 TOF7FLUSH (2) 2X10FLUSH 3-PLY 14" LVL18" DEEP TRUSSES24" O.C. BASE SPACING.DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING. TRUSSES HAVE BEEN HELD IN1/2" AT EXTERIOR WALLS FOR SHEATHING.THE PAINTED END DENOTES THE LEFT ENDOF THE FLOOR TRUSS. THIS END OF THEFLOOR TRUSS IS TO BE PLACED WHERE YOUSEE THE TRIANGLE AND THE PAINTED ENDNOTE ON THE PLACEMENT PLAN. THEPAINTED END ALSO CORRESPONDS TO THELEFT SIDE OF THE SEALED TRUSS DRAWING.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBINGLOCATIONS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLJOSH @ 651-287-1944OREMAIL: JRUDESILL@VILLAUME.COMPAINTED ENDPAINTED ENDPAINTED ENDF14-F18F16F4F17F19F13F23F14F1F14F2F14F2F14F3F14F3F10F11F11F11F11F11F9F6F6F6F22F22F22F22F22F22F22F5F23F12F12F12F12F12F15F9F22F1016-00-004-00-004-00-0010-10-002-00-0012-00-0022-00-00 6-00-0042-00-0036-00-006-00-0022-08-007-10-00 11-06-0010-00-00 15-00-0017-00-0042-00-001-10-042-00-002-00-002-00-002-00-0011-121-03-121-08-082-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-10-042-00-002-00-002-00-002-00-001-02-128-00-00 4-00-006-042-00-001-05-12Customer: Lyman Lumber - ChanhassenJob Number: 327636-CHome Owner: TOPAZ / MAVERICK / PETERSON RESJob Name: 1st FloorSite Address: 17749 EMERALD CT Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Josh Rudesill2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 6/19/2024Version: 8.7.3.303 POST-UP OR 2400 GRADELUMBER TOP PLATE ATBOTH ENDS OF G3FRAME KNEE WALLOFF BOTTOM CHORDOF G3 WITH (14) HUS2816186# D0# U16732# D0# U9285# D0# U8464# D0# UFLUSH (2) 2X10FLUSH 2-PLY 11-7/8" LVLFLUSH 3-PLY 14" LVLPAINTED ENDPAINTED END20" DEEP TRUSSES24" O.C. BASE SPACING.DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING. TRUSSES HAVE BEEN HELD IN1/2" AT EXTERIOR WALLS FOR SHEATHING.THE PAINTED END DENOTES THE LEFT ENDOF THE FLOOR TRUSS. THIS END OF THEFLOOR TRUSS IS TO BE PLACED WHERE YOUSEE THE TRIANGLE AND THE PAINTED ENDNOTE ON THE PLACEMENT PLAN. THEPAINTED END ALSO CORRESPONDS TO THELEFT SIDE OF THE SEALED TRUSS DRAWING.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBINGLOCATIONS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLJOSH @ 651-287-1944OREMAIL: JRUDESILL@VILLAUME.COMFLUSH 2-PLY 14" LVLFF17FF2FF23FF15FF22FF22FF1FF2XFF3FF3FF3FF5FF9FF9FF10FF11FF12FF14FF14FF14FF14FF14FF20FF8FF21FF21FF21FF21FF21FF21FF21FF4FF7FF8FF6FF5FF16FF16FF16FF16FF16FF16FF18FF19FF19FF24FF18FF5FF19FF8FF21G3H1HGUS210-2LUS410LUS410LUS410LUS410LUS410LUS410LUS410LUS410LUS410LUS410LUS410LUS41016-00-004-00-004-00-005-10-0011-08-004-02-0040-00-0017-06-009-00-0015-06-0040-00-0022-06-0021-06-00 6-00-0050-00-008-00-0036-00-006-00-0036-00-007-04-00 11-06-0012-10-00 10-00-00 15-00-0017-00-0054-10-001-10-042-00-002-00-002-00-001-10-003-122-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-04-001-00-001-10-042-00-002-00-002-00-002-00-004-00-002-00-009-041-04-001-04-001-04-001-09-006-042-00-001-05-126-00-008-082-00-002-00-002-00-00Customer: Lyman Lumber - ChanhassenJob Number: 327636-CHome Owner: TOPAZ / MAVERICK / PETERSON RESJob Name: 1st FloorSite Address: 17749 EMERALD CT Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Josh Rudesill2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 6/19/2024Version: 8.7.3.303 POST-UP OR 2400 GRADELUMBER TOP PLATE ATBOTH ENDS OF G316186# D0# U16732# D0# U9285# D0# U8464# D0# UDIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING.THE TRUSS ID DOES NOT DENOTE THE LEFTEND OF THE ROOF TRUSS ON THEPLACEMENT PLAN. USE THE LEFT END OFTHE SEALED TRUSS DRAWING AND THETRIANGLE ON THE PLACEMENT PLAN TOLOCATE THE PROPER END OF EACH ROOFTRUSS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLJOSH @ 651-287-1944OREMAIL: JRUDESILL@VILLAUME.COMG2G1G1G1G3H1L1J1J1J1J1J1J1J1J1J1J1J1K1K1K1K1K1K1K1K3K3K3K1G1G1G1HGUS210-240-00-0017-06-009-00-0015-06-0040-00-0022-06-0021-06-00 6-00-0050-00-008-00-0036-00-006-00-0036-00-007-04-00 11-06-0012-10-00 10-00-00 15-00-0017-00-0054-10-006-00-001-00-006-00-008-082-00-002-00-002-00-00A1A1A1A1A1A1A1A1A1A1A1A1A1A1A3A3A3A3A4E2E1E3E3A2C1D1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P2P216-01-001-11-042-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-00Customer: Lyman Lumber - ChanhassenJob Number: 327636-CHome Owner: TOPAZ / MAVERICK / PETERSON RESJob Name: 1st FloorSite Address: 17749 EMERALD CT Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Josh Rudesill2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 6/19/2024Version: 8.7.3.303 Date Certificate Posted X Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here R-15 X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X X R-30 X X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: 90,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93 Cfm's X " round duct OR 7" flex " metal duct Not required per mech. code X Passive Low: Other, describe: X Low: Location of fan(s), describe: Cfm's X " round duct OR 7" flex " metal duct ML19309016C Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 3.550 Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: 180 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 42545Residential Load Calculation SEER /EER Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 14 Building envelope air tightness: Rim Joist (1st Floor) GPVL5000L 13ACZ042P Model Heating System Natural Gas Lennox Fiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.32 Describe other insulated areas Fiberglass, BlownTHERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not Applicable Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.27 Appliances Mechanical room Mechanical room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 70813 Heating Gain Cooling Load 90 Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.6/26/2024 New Construction Energy Code Compliance Certificate Name of Residential Contractor One Ten Ten Homes, LLC MN License Number Lakeville17749 Emerald Court BC730925 City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 3.5 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 * If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to erosion@lakevillemn.gov “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) 7/2/24 X PM