HomeMy WebLinkAboutLA225893 - 17967 Hawksbill Dr-Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
_____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
NAME OF APPLICANT (Please Print)DATE
I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS
APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO
COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH
LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED
PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE
CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE
ESCROW APPLICATION AND REFUND.
OFFICE PHONE #:_
OFFICE PHONE #:_
*Entering your name affirms your intent to comply with the statement above.
*
Submit Application To: permits@lakevillemn.gov
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT
CONDO
REROOF
RESIDE
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES
LOWER LEVEL FINISH
ADDITION
FOUNDATION ONLY
MISCELLANEOUS
DEMO
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
CITY BUILDING VALUATION: $
BUILDING PERMIT FEES
$PERMIT FEE
$PLAN CHECK
$SURCHARGE
$METRO SAC
$CITY WATER HOOKUP UNIT
$CITY SEWER HOOKUP UNIT
$LANDSCAPE ESCROW
$TREE ESCROW
$MISC ESCROW
$PLUMBING
$MECHANICAL
$SEWER WATER
WATER METER
PRESSURE REDUCING VALVE
$OTHER
$TOTAL
METER SIZE
PRESSURE REDUCING VALVE
SEWER/WATER
SEWER/WATER
FINAL
STREET DRAINTILE
BUILDING INFORMATION
TYPE OF CONSTRUCTION
ZONING
CODE EDITION
FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
MECHANICAL
AIR TEST
FINAL
ROUGH-IN
PLUMBING
FINAL
ROUGH-IN
INSULATION
LATH
DECK FOOTING
FIREPLACE
FOOTING
FOUNDATION
FRAMING
PORCH FRAMING
PORCH FOOTING
POURED WALL
SITE
LOWER LEVEL FINAL
OTHER
DECK FRAMING
LOWER LEVEL FRAMING
LANDSCAPING
DECK FINAL
$
$
ACCESSORY BUILDING
EGRESS WINDOW
UNDERGROUND
Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode07/24/2024jnuetzman
UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.
-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).BWPsAboveBWPsAboveBWPsAbove3.5Shearwall6663.536PFHPFH5575Shear Panelw/holdownsShear Panelw/holdowns
-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).33
5(4#/+0)&'6#+.)#4#)'(41062146#.(4#/'ÄÄ01661':%''&Ä.'0)6*1(%106+07175*'#&'4(#56'06122.#6'61*'#&'4Y
4195F5+0-'40#+.5"1%
Z$'#4+0)567&
Z(7..*'+)*6567&'#%*'0&1(*'#&'4.1%#6'2#0'.,1+069+6*+0Ä(41/%'06'41(*'#&'4*'+)*6#54'3&
Z51.+&$.1%-+0)4'37+4'A*'#6*+0),1+06
Z$'#4+0)567&5/+0
8'4+(;Y5722.+'42418+&'Z+0(+..9#..#$18'*'#&'4#54'3&5+/251056*&'/$'&&'&*1.&190#0%*14#6.1%#6+1055*190
4'('4615(14#.6'40#6+8'126+105(170+109#..$'.19
#0%*14$1.65
/+0'/$'&YZZ2.#6'9#5*'450#+.5*'#6*+0)61*'#&'4YF0#+.5"1%'#9#;6;25/#..*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5
0#+.5*'#6*+0)#4170&2'4+/'6'4Y
4195F0#+.5"1%56#))'4'& 612.#6'5$.1%-+0)"1%5+/2510/56%564#210+05+&'(#%'1(9#..
2418+&'52#%'461(.75*176*'#&'4619#..567&6*+%-0'55(#56'0-+0)567&61*'#&'4Y
4195F5+0-'40#+.5"1%.#4)'*#6%*#4'#+0&+%#6'5146*+%-'42.;911&1415$5*'#6*+0)#22.+'&61':6'4+145+&'1(567&5Y56#0&0#+.+0)(#56'0(4#/+0)#$18'#55*190(14$4#%'&9#..2#0'.5%106+07175.8.*'#&'46157221468'46+%#..1#&5$;5722.+'4
/+09+&6* /+0&'26*4'3&Ä%12;4+)*6*#0510)4172..%&GUETKRVKQP&CVG4GXKUKQP,WN[2TQLGEV0WODGT&CVG55JGGVUQH-G[.CPF*QOGU(KUJ2QKPV4F5'2TKQT.CMG/02.#055*190.+)*6+0$#%-)4170'(14.1%#6+104'('4'0%'10.;2.#0016'5#0&'.'/'0655*190.+)*6/#;0160'%'55#4+.;57221466*'*#0510)41725&'5+)02TKPV0COG5KIPGF.KEGPUG0WODGTÄÄ&CVG+JGTGD[EGTVKH[VJCVVJKURNCPURGEKHKECVKQPQTTGRQTVYCURTGRCTGFD[OGQTWPFGTO[FKTGEVUWRGTXKUKQPCPFVJCV+COCFWN[.KEGPUGF2TQHGUUKQPCN'PIKPGGTWPFGTVJGNCYUQHVJG5VCVGQH/KPPGUQVC6*+55*''654'24'5'065#%1/2.'6'&'5+)01(6*'/#+09+0&(14%'4'5+56+0)5;56'/(146*''06+4'4'5+&'06+#.5647%674'6*'.1%#6+10#0&.'0)6*1('#%*$4#%'&9#..2#0'.#0&'0)+0''4'&9+0&4'5+56+0)'.'/'066*#6+54'37+4'&(146*'*#0510)41725&'5+)0+55*190106*'5647%674#.&4#9+0)59#..501652'%+(+%#..;.#$'.'&106*'2.#05/#;$'56#0&(4#/+0)5'%6+1055*190&'2+%6%100'%6+1051($4#%'&9#..2#0'.561411(64755'5#$18'61,1+56564755'5$.1%-+0)#$18'#0&61,1+56564755'5$.1%-+0)$'.196*'5'2#0'.5#4'0160'%'55#4+.;4'37+4'&61#.+)0$76/#;&'2'0&+0)102.#0.#;176411(64755'5$4#%'&9#..2#0'.(.#6Z"1%
/+0
2'4$4#%'&9#..2#0'.5+/2510#(4#/+0)#0).''#%*'0&
Z0#+.52418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'.
Z0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+5652418+&'9+&6*9'$56+(('0'4(14#66#%*/'061((4#/+0)#0).'$4#%'&9#..2#0'.
Z0#+.55+/2510#(4#/+0)#0).''#%*'0&(.114,1+565$4#%'&9#..2#0'.
Z0#+.55+/2510.62(4#/+0)2.#6''#%*'0&(.11464755'5(.#6Z"1%
/+0
2'4$4#%'&9#..2#0'.(.#6Z"1%
/+0
2'4$4#%'&9#..2#0'.(.#6Z"1%
/+0
2'4$4#%'&9#..2#0'.$4#%'&9#..2#0'.
Z0#+.55+/2510.62(4#/+0)2.#6''#%*'0&(.11464755'5(.#6Z"1%
/+0
2'4$4#%'&9#..2#0'.$4#%'&9#..%100'%6+10$4#%'&9#..%100'%6+10$4#%'&9#..%100'%6+10
411(64755'5
(.114,1+565
(.11464755'5&'6#+.55*190#$18'#4'#.6'40#6+8'%100'%6+10561$'75'&9*'0$4#%'&9#..2#0'.&1'5016#.+)09+6*(4#/+0)':6'4+14010Ä$'#4+0)9#..(4#/'Z$1:#4170&52#%'$'69''064755Y5#/'5*'#6*+0)#0&(#56'0+0)#59#..$'.19
144'2.#%'Y#&'37#6'&'26*Z/'/$'4Z911&5%4'95"1%+056#..'&+0#&&+6+10610#+.5
/#+0722'4.'8'.411(64755$'#4+0)9#..510.;Z911&5%4'95"1%+056#..'&+0#&&+6+10610#+.5
/#+0722'4.'8'.411(64755$'#4+0)9#..510.;':6'4+14$'#4+0)9#..4'24'5'065(+)74'4
+0&+%#6'5+06'4+14$4#%'&9#..2#0'.Y);257/5*'#6*+0)$16*(#%'59+6*'+6*'4(#56'0'4126+10.+56'&+0016'52#%'=%2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19+0&+%#6'5'0)+0''4'&9+0&4'5+56+0)'.'/'06561$'%105647%6'7*190+06*'&'6#+.5*''65
/+0.'0)6*+0&+%#6'5':6'4+14$4#%'&9#..2#0'.Y5*'#6*+0)10':6'4+14(#%'+0#%%14�%'Y016'2418+&'+0%4'#5'&(#56'0+0)4'37+4'/'065#55*190$'.19
/+0.'0)6*Y,1+565Y64755'5Y,1+565Y64755'5Y,1+565Y64755'5Y,1+565Y64755'55%12'&'5+)0#0&&'6#+.1(6*'/#+09+0&(14%'4'5+56+0)5;56'/(14#5+0).'Ä(#/+.;4'5+&'0%'%105647%6+10+561$'+0#%%14�%'9+6*6*+5&1%7/'0656#0&+0&7564;24#%6+%'#0&6*'%1&'016'56*'5'&1%7/'065#22.;615647%674#.10.;4'('461%105647%6+10&1%7/'065(14/14'+0(14/#6+10#..':6'4+149#..5#4'61$'%105647%6'&+0#%%14�%'9+6*6*'(1..19+0)%4+6'4+#7019*+%*/''6514':%''&56*'4'37+4'/'0651(%1&'5'%6+104Ä952#0&%5Ä952#Z567&552#%'&"1%$':6'4+145*'#6*+0)/+05647%674#.2#0'.5*'#6*+0)YF%1//100#+.5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'5722146514)#7)'56#2.'5"52#%+0)#..+06'4+149#..5#4'61$'%105647%6'&+0#%%14�%'9+6*6*'(1..19+0)%4+6'4+#701#Z14Z567&552#%'&"1%$9#..5*'#6*+0)/+0);257/5*'#6*+0)(#56'0'&61(4#/+0)YF%11.'40#+.5"1%/#:146;2'599#..$1#4&5%4'95"1%/#:
/+0+/7/567&2'0'64#6+10#..(.1145#4'61$'%105647%6'&+0#%%14�%'9+6*6*'(1..19+0)%4+6'4+##(.114(4#/+0)52#%'#/#:+/7/1(1%$(.1145*'#6*+0)5647%674#.2#0'.5*'#6*+0)YF%1//100#+.5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'57221465#..411(5#4'61$'%105647%6'&+0#%%14�%'9+6*6*'(1..19+0)%4+6'4+##411((4#/+0)52#%'#/#:+/7/1(1%$(#56'0#..411((4#/+0)616122.#6'59+6*5+/2510*%.+214'37+8#.'06#0&
Z61'0#+.5%411(5*'#6*+0)5647%674#.2#0'.5*'#6*+0)YF%1//100#+.5"1%#62#0'.'&)'5#0&1%#6+06'4/'&+#6'5722146514)#7)'56#2.'5"52#%+0)#.10).'0)6*1(9#..5.#29#..6122.#6'5#/+0+/7/1(#0&(#56'061)'6*'49+6*
Z+0.#2<10'#6%140'45#0&+06'45'%6+105.#22.#6'5#0&2418+&'
Z(#%'0#+.5%100'%6+10501652'%+(+%#..;016''61$'+0#%%14�%'9+6*%1&'6#$.'4
6#..911&9#..(4#/+0)+561$'&'5+)0'&$;5722.+'4(14)4#8+6;#0&176Ä1(Ä2.#0'9+0&.1#&56*''064;214%*+5%105+&'4'&61$'#24+/#4+.;12'0010Ä'55'06+#.2146+101(6*'5647%674'#0&+5':%.7&'&(41/6*'18'4#../#+09+0&(14%'5;56'/1(6*'*1/'2418+&'%1&'4'37+4'&72.+(6%100'%6+105#6#..21565/#6'4+#.59#..567&5
14.'5552(567&)4#&'14$'66'49#..567&5
18'452(01)4#&'14$'66'4&+/'05+10#..7/$'452(01)4#&'14$'66'464'#6'&.7/$'45;201)4#&'14$'66'4.5.9+&6*Ä'14$'66'4.8.9+&6*Ä'14$'66'4.1#&5411(5019.1#&Ä25(411(&'#&.1#&25((.114.+8'.1#&25((.114&'#&.1#&25(9+0&.1#&/2*7.6+/#6'':2$%1&'/+00'516#4'5+&'06+#.%1&'411(64755'5(#56'0'&612.#6'5Y
Z61'0#+.5 5+/2510*%.+20#+.$1661/2.#6'614+/,1+56$.1%-+0)Y
F0#+.5'8'4;0#+.$1661/2.#6'614+$$10$4#%'64755Y
F0#+.5'8'4;0#+.'#%*,1+56616122.#6'5Y
Z0#+.5Z$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y
Z0#+.5'#%*0#+.'#%*64755616122.#6'5Y
Z61'0#+.5411(64755(#56'0'&612.#6'5YZ61'0#+.5"1%0#+.$1661/2.#6'614+/,1+56$.1%-+0)Y
F0#+.5'8'4;0#+.4+/6122.#6'5YZ61'0#+.5"1%0#+.$1661/2.#6'61.#&&'464755Y
F0#+.5'8'4;0#+..#&&'464755616122.#6'5YZ0#+.5"1%+06'4+149#..2'42'0&+%7.#461(4#/+0)+06'4+149#..2#4#..'.Y(4#/+0)Z$.1%-+0)$'69''0411(64755'50#+.'&616122.#6'5Y
Z0#+.5'#%*0#+.$1661/2.#6'61$.1%-+0)Y
F0#+.5'8'4;2418+&'(7..&'26*$.1%-+0)$'69''0,1+5650#+.'&616122.#6'5Y
Z0#+.5'#%*0#+.'#%*,1+56616122.#6'Y
Z0#+.50#+.$1661/2.#6'61$.1%-+0)Y
F0#+.5'8'4;2418+&'(7..&'26*$.1%-+0)$'69''064755'50#+.'&616122.#6'5Y
Z0#+.5'#%*0#+.'#%*64755616122.#6'Y
Z61'0#+.52418+&'411(64755&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YZ61'0#+.5"1%0#+.$1661/2.#6'61$.1%-+0)Y
F0#+.5'8'4;2418+&',1+56&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YZ61'0#+.5"1%0#+.$1661/2.#6'61$.1%-+0)Y
F0#+.5'8'4;2418+&'64755&+4'%6.;+0.+0'Y$4#%'&9#..2#0'.(#56'0'&612.#6'5YZ61'0#+.5"1%2NCPÄ++5VCNN)CTCIG/KPPGUQVC%QPUVTWEVKQP%GFCT.CMG4QCF5WKVG5V.QWKU2CTM/06GNÄÄYYYJCPUQPITQWROPEQO2#46+#..19'4.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;
#%67#..#;176/#;$'/+4414'&54'('4'0%'2.#0/#+0.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;
#%67#..#;176/#;$'/+4414'&54'('4'0%'2.#0722'4.'8'.*175'2.#05*190(14.1%#6+104'('4'0%'10.;
#%67#..#;176/#;$'/+4414'&54'('4'0%'2.#0016'+0(1#22.+'55;//'64+%#..;#%4155&'6#+.70.'55016'&5*19016*'49+5'5(4#/+0)&'6#+.2'4(14#6'&5*'#49#..2418+&'&17$.'567&5#6'#%*'0&1(5*'#49#..
/#;75'$'#4+0)-+0)567&5#54'3&*#6%*''#+0&+%#6'5146*+%-'42.;911&15$':6'4+145*'#6*+0)(#56'0'&61567&5YF0#+.5"1%#62#0'.'&)'5 "1%#6+06'4+14572214656;2+%#.Z567&5"1%(#56'0$1661/2.#6'Y
F0#+.5'8'4;(#56'0(4#/+0)#$18'#55*190(14$4#%'&9#..2#0'.5*'#&'4 $'#4+0)-+0)567&5#65+&'51(12'0+0)5$;5722.+'45+/2510/56%564#2(#56'0'&61&17$.'567&5 (.1144+/%10%4'6'(170+10$'.195+/2510*66*1.&190#0%*14#6.1%#6+1055*190YZ.10)5+/25106+6'0*&5%4'9Ä+0#0%*142156Ä+056#..'&*1.&190126+1055(4#/+0)&'6#+.016'+0(1#22.+'55;//'64+%#..;#%4155&'6#+.70.'55016'&5*19016*'49+5'#0%*14$1.6
/+0'/$'&YZZ2.#6'9#5*'4
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6$4#%'&
9#...+0'
$4#%'&
9#...+0'
$4#%'&
9#...+0'$4#%'&9#...+0'$4#%'&9#...+0'
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6
Ä(6$4#%'&
9#...+0'
$4#%'&
9#...+0'
$4#%'&
9#...+0'$4#%'&9#...+0'$4#%'&9#...+0'$4#%'&9#...+0'
Ä(6
Ä(6
Ä(6
Ä(6$4#%'&9#...+0'%105647%62146#.(4#/'#55*190+05%105647%65*'#49#..#55*190+050KEM*CPUQP5(4#/+0)&'6#+.)#4#)'5*'#49#..(#56'0(4#/+0)#$18'#55*190(14$4#%'&9#..2#0'.5#.10)6*+55*'#49#..#59'..#5#$18'18'4*'#&&114*#6%*''#+0&+%#6'5146*+%-'42.;911&15$':6'4+145*'#6*+0)(#56'0'&61567&5YF0#+.5"1%#62#0'.'&)'5 "1%#6+06'4+1457221465
#0%*14$1.65
/+0'/$'&6;2+%#.Z567&5"1%2418+&'&17$.'567&5#6'0&1(5*'#49#..*'#&'4 $'#4+0)-+0)567&521565#65+&'51(12'0+0)5$;5722.+'45+/251056*&*1.&190#0%*14(#56'0'&61&17$.'567&5
4'('4615(142156Ä+056#..'&*1.&190126+10%105647%65*'#49#..#55*190+05%105647%65*'#49#..#55*190+05/+4414'&1/+6$4#%'&9#..2#0'.+((7..*'+)*6%10%4'6'
FLUSH 3PLY 18" LVLFLUSH 18" LVL
DROPPED LVL
PLUMBING LOCATIONODD SPACE
MECH.
CHASE
E3 TRUSSES BEARON UPPER LEVEL WALL
2X6 LEDGER-ATTACHMENT
DESIGNED BY OTHERS BEARING BLOCK
12'-1 1/8" WALL
12'-1 1/8" WALL 12'-1 1/8" WALL
PAINTED END OF TRUSS
PAINTED END OF TRUSS
PAINTED END OF TRUSS
18" DEEP TRUSSES
19.2" O.C. BASE SPACING.
DIMENSIONS ARE FROM THE OUTSIDE OF
FRAMING.
THE PAINTED END DENOTES THE LEFT END
OF THE FLOOR TRUSS. THIS END OF THE
FLOOR TRUSS IS TO BE PLACED WHERE YOU
SEE THE TRIANGLE AND THE PAINTED END
NOTE ON THE PLACEMENT PLAN. THE
PAINTED END ALSO CORRESPONDS TO THE
LEFT SIDE OF THE SEALED TRUSS DRAWING.
PLUMBING LOCATIONS ARE ESTIMATED.
CONTRACTOR TO VERIFY PLUMBING
LOCATIONS.
DO NOT CUT TRUSSES.
IF YOU HAVE ANY QUESTIONS OR
CONCERNS, PLEASE CALL JOHN @ 651-688-
3609 OR EMAIL: JMILLER@TRUSSABC.COMFF1
FF10FF14FF12FF2FF2FF2FF2FF2FF2FF8FF8FF8FF5FF8FF5FF9FF6FF9FF6FF9FF6FF9FF6FF9FF7FF9FF9FF9FF4FF3FF13FF11FF15FF15FF9FF9E1E1E1E1E3E2D2
C2C1C1C1C1C1A1A1A2E3E3E3A1E1C1D1
D1
V2
V3
V4
V5
V6
V7
V110-10-0014-10-002-11-004-00-0422-02-1210-00-00 22-00-00 20-00-00
11-00-00 15-00-00 18-00-00 8-00-00
52-00-00
4-00-0029-00-0011-00-001-05-071-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-05-071-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-032-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-0022-05-0820-00-0022-00-0044-00-001-11-04
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00 2-00-006-00-002-00-00
Customer: Key Land HomesJob Number: 327581-BHome Owner: 2614 II B-SPECJob Name: FloorSite Address: 17967 HAWKSBILL DRIVE Sales Rep: John FrankCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Unassigned2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 6/10/2024Version: 8.7.3.303
E3 TRUSSES BEARON UPPER LEVEL WALL
2X6 LEDGER-ATTACHMENT
DESIGNED BY OTHERS BEARING BLOCK
12'-1 1/8" WALL
12'-1 1/8" WALL 12'-1 1/8" WALL
BEARING WALL
CANTED TRUSSES
BEARING BLOCK
DIMENSIONS ARE FROM THE OUTSIDE OF
FRAMING.
THE TRUSS ID DOES NOT DENOTE THE LEFT
END OF THE ROOF TRUSS ON THE
PLACEMENT PLAN. USE THE LEFT END OF
THE SEALED TRUSS DRAWING AND THE
TRIANGLE ON THE PLACEMENT PLAN TO
LOCATE THE PROPER END OF EACH ROOF
TRUSS.
DO NOT CUT TRUSSES.
IF YOU HAVE ANY QUESTIONS OR
CONCERNS, PLEASE CALL JOHN @ 651-688-
3609 OR EMAIL: JMILLER@TRUSSABC.COME1E1E1E1E3E2D2C2C1C1C1C1C1A1A1A2E3E3E3A1E1C1D1
D1
V2
V3
V4
V5
V6
V7
V1
TBE4
10-00-00 22-00-00 20-00-00
11-00-00 15-00-00 18-00-00 8-00-00
52-00-00
4-00-0029-00-0011-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-0022-05-0820-00-0022-00-0044-00-001-11-04
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00 2-00-006-00-002-00-00
K6
K2
K1
K1
K3
K3
K3
K3
K3
K3
K4
K5G1G1G1G1G2G3G3G3H3H1H1H1H1H2L1V8
V9FV10FLUS28LUS28LUS282-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-11-04
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
2-00-00
Customer: Key Land HomesJob Number: 327581-AHome Owner: 2614 II B-SPECJob Name: RoofSite Address: 17967 HAWKSBILL DRIVE Sales Rep: John FrankCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Unassigned2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 6/10/2024Version: 8.7.3.303
TOTAL INPUT OF APPLIANCES1,
THOUSANDS OF Btu/hr
(kW)
REQUIRED FREE AREA OF AIR-SUPPLY
OPENING OR DUCT, SQUARE INCHES
(sq mm)
ACCEPTABLE APPROXIMATE ROUND DUCT
EQUIVALENT DIAMETER2,
INCH (mm)
25 (8)7 (4,500)3 (75)
50 (15)7 (4,500)3 (75)
75(23)11 (7,000)4 (100)
100 (30)14 (9,000)4 (100)
125 (37)18 (12,000)5 (125)
150 (45)22 (14,000)5 (125)
175 (53)25 (16,000)6 (150)
200 (60)29 (19,000)6 (150)
225 (68)32 (21,000)6 (150)
250 (75)36 (23,000)7 (175)
275 (83)40 (26,000)7 (175)
300 (90)43 (28,000)7 (175)
325 (98)47 (30,000)8 (200)
350 (105)50 (32,000)8 (200)
375 (113)54 (35,000)8 (200)
400 (120)58 (37,000)9 (225)
1. For total inputs falling between listed capacities, use next largest listed input.
2. If flexible duct is used, increase the duct diameter by one inch. *
*Flexible duct shall be stretched with minimal sags.
TABLE 304.1
COMBUSTION AIR REQUIREMENTS FOR GAS-FIRED
APPLIANCES WHEN THE COMBINED INPUT IS UP TO
AND INCLUDING 400,000 Btu/hr
BTU Amount for Non-direct vent appliances_____________________
1 2 3 4 5 6 2
Conditioned space1 (in sq. ft.)
Total/
Continuous
Total/
Continuous
Total/
Continuous
Total/
Continuous
Total/
Continuous
Total/
Continuous
1000-1500 60/40 75/40 90/45 105/53 120/60 135/68
1501-2000 70/40 85/43 100/50 115/58 130/65 145/73
2001-2500 80/40 95/48 110/55 125/63 140/70 155/78
2501-3000 90/45 105/53 120/60 135/68 150/75 165/83
3001-3500 100/50 115/58 130/65 145/73 160/80 175/88
3501-4000 110/55 125/63 140/70 155/78 170/85 185/93
4001-4500 120/60 135/68 150/75 165/83 180/90 195/98
4501-5000 130-65 145/73 160/80 175/88 190/95 205/103
5001-5500 140/70 155/78 170/85 185/93 200/100 215/108
5501-6000 2 150/75 165/83 180/90 195/98 210/105 225/113
1. Conditioned space includes the basement and conditioned crawl spaces.
2. If conditioned space exceeds 6000 sq. ft. or there are more than 6 bedrooms, use Equation R403.5.2
R403.5.2 Total Ventilation rate.
The mechanical ventilation system shall rovide sufficient outdoor air to equal the total ventilation rate average
for each 1- hour period in accordance with Table R403.5.2, or Equation 403.5.2, based on the number of bedrooms and
square footage of conditioned space, including the basement and conditioned crawl spaces.
For the purposes of Table R403.5.2 and Section R403.5.3, the following applies:
a. Equation R403.5.2 Total ventilation rate:
Total ventilation rate (cfm) = (0.02 x square feet of conditioned space) + (15 x (number of bedrooms +1))
b. Equation R403.5.2.1 Continuous ventilation rate: Continuous ventilation rate (cfm) = Total ventiation rate/2
Amount Total _________________________
Amount Continuous____________________
TABLE R403.5.2
NUMBER OF BEDROOMS
VENTILATION REQUIREMENTS
ONE OR MULTIPLE POWER VENT
OR DIRECT VENT APPLIANCES OR
NO COMBUSTION APPLIANCESA
ONE OR MULTIPLE FAN-
ASSISTED APPLIANCES AND
POWER VENT OR DIRECT
VENT APPLIANCESB
ONE ATMOSPHERICALLY
VENTED GAS OR OIL
APPLIANE OR ONE
SOLID FUEL APPLIANCEC
MULTIPLE APPLIANCES THAT
ARE ATMOSPHERICALLY
VENTED GAS OR OIL
APPLIANCES OR SOLID FUEL
APPLIANCESD
1. Use the Appropriate Column to Estimate House Infiltration
a) pressure factor
(cfm/sf)
b) conditioned floor
area (sf)
(including unfinished basements)
Estimated House
Infiltration (cfm):
[1a x 1b]
2. Exhaust Capacity
a) clothes dryer
b) 80% of largest
exhaust rating (cfm):
(not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust)
c) 80% of next largest
exhaust rating (cfm):not applicable
(not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust)
Total Exhaust Capacity
(cfm):
[2a+2b+2c]
3. Makeup Air Requirement
a) Total Exhaust
Capacity
(from above)
b) Estimated House
Infiltration (from
above)
Makeup Air
Quality (cfm):
[3a - 3b]
(if value is negative, no makeup air is needed
4. For Makeup Air Opening Sizing, refer to Table 501.4.2.
A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances.
B. Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included.
C. Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance.
D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically
vented gas or oil appliances and solid fuel appliances.
Table 501.4.1
Procedure to Determine Makeup Air Quantity for Exhaust Appliances in Dwelling Units
Choose Which Applies
TYPE OF OPENING
ONE OR MULTIPLE POWER
VENT OR DIRECT VENT
APPLIANCES OR NO
COMBUSTION
APPLIANCESA
ONE OR MULTIPLE FAN-
ASSISTED APPLIANCES
AND POWER VENT OR
DIRECT VENT APPLIANCESB
ONE
ATMOSPHERICALLY
VENTED GAS OR OIL
APPLIANCE OR ONE
SOLID FUEL
APPLIANCEC
MULTIPLE APPLIANCES
THAT ARE
ATMOSPHERICALLY
VENTED GAS OR OIL
APPLIANCES OR SOLID
FUEL APPLIANCESD
PASSIVE MAKEUP
AIR OPENING
DUCT
DIAMETERE,F,G
OR SYSTEM (cfm)(cfm)(cfm)(cfm)(inches)
Passive opening 1-36 1-22 1-15 1-9 3
Passive opening 37-66 23-41 16-28 10-17 4
Passive opening 67-109 42-66 29-46 18-28 5
Passive opening 110-163 67-100 47-69 29-42 6
Passive opening 164-232 101-143 70-99 43-61 7
Passive opening 233-317 144-195 100-135 62-83 8
Passive opening
with motorized
damper 318-419 196-258 136-179 84-110 9
Passive opening
with motorized
damper 420-539 259-332 180-230 111-142 10
Passive opening
with motorized
damper 540-679 333-419 231-290 143-179 11
Powered makeup
airH >679 >419 >290 >179 Not applicable
A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances.
B. Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included.
C. Use this column if there is one atmospherically vented (ther than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance.
D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented
gas or oil appliances and solid fuel appliances.
E. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90-degree
elbow to determine the remaining length of straight duct allowable.
F. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags.
G. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed.
H. Powered makeup air shall be electrically interlocked with the largest exhaust system.
Table 501.4.2
Makeup Air Opening Sizing Table for New and Existing Dwelling Units
IFGC Appendix E, Worksheet E-1
Residential Combustion Air Calculation Method
(for Furnace, Boiler, and/or Water Heater in the Same Space)
Step 1: Complete vented combution appliace information:
Furnace/Boiler:
Draft Hood Fan Assisted Direct Vent Input: Btu/hr
(Not fan Assisted) & Power Vent
Water Heater:
Draft Hood Fan Assisted Direct Vent Input: Btu/hr
( Not fan Assisted) & Power Vent
Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances.
The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft3
Step 3: Determine air Changes per Hour (ACH)1
Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction
or ACH is not known, use method 4a (Standard Method).
Step 4: Determine Required Volume for Combustion Air.
4a. Standard Method
Total Btu/hr input of all combustion appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Input: Btu/hr
Use Standard Method column in Table E-1 to find Total Required Volume (TRV) TRV: ft3
If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed.
If CAS Volume (from Step 2) is less than TRV then go to STEP 5.
4b. Known Air Infiltration Rate (KAIR) Method
Total Btu/hr input of all fan-assisted and power vent appliances
(DO NOT COUNT DIRECT VENT APPLIANCES) Input: Btu/hr
Use Fan-Assisted Appliances column in Table E-1 to find
Required Volume Fan Assisted (RVFA) RVFA: ft3
Total Btu/hr input of all non-fan-assisted appliances Input: Btu/hr
Use Non-Fan-Assisted Appliances column in Table E-1 to find
Required Volume Non-Fan-Assisted (RVNFA) RVNFA: ft3
Total Required Volume (TRV) = RVFA + RVNFA TRV = + = ft3
If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed.
If CAS Volume (from Step 2) is less than TRV then go to STEP 5.
Step 5: Calculate the ratio of available interior volume to the total required volume.
Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio =
Step 6: Calculate Reduction Factor (RF).
RF = 1 minus Ratio RF = - =
Step 7: Calculate single outdoor opening as if all combustion air is from outside.
Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Input: Btu/hr
Combustion Air Opening Area (CAOA):
Total Btu/hr divided by 3000 Btu/hr per in2 / Btu/hr per in
2 = in2
Step 8: Calculate Minimum CAOA.
Minimum CAOA = CAOA multiplied by RF Minimum CAOA = x = in2
Step 9: Calculate Combustion Air Opening Diameter (CAOD)
CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 x Minimum CAOA = in
1If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section 304.
CAOA =
IFGC Appendix E, Table E-1
Residential Combustion Air Required Volume (Required Interior Volume Based on Input Rating of Appliances)
Known Air Infiltration Rate (KAIR) Method (ft3)
Input Rating Standard Method Fan Assisted Non-Fan-Assisted
(Btu/hr) (ft3) 19941 to Present Pre 19942 19941 to Present Pre 19942
5,000 250 375 188 525 263
10,000 500 750 375 1,050 525
15,000 750 1,125 563 1,575 788
20,000 1,000 1,500 750 2,100 1,050
25,000 1,250 1,875 938 2,625 1,313
30,000 1,500 2,250 1,125 3,150 1,575
35,000 1,750 2,625 1,313 3,675 1,838
40,000 2,000 3,000 1,500 4,200 2,100
45,000 2,250 3,375 1,688 4,725 2,363
50,000 2,500 3,750 1,875 5,250 2,625
55,000 2,750 4,125 2,063 5,775 2,888
60,000 3,000 4,500 2,250 6,300 3,150
65,000 3,250 4,875 2,438 6,825 3,413
70,000 3,500 5,250 2,625 7,350 3,675
75,000 3,750 5,625 2,813 7,875 3,938
80,000 4,000 6,000 3,000 8,400 4,200
85,000 4,250 6,375 3,188 8,925 4,463
90,000 4,500 6,750 3,375 9,450 4,725
95,000 4,750 7,125 3,563 9,975 4,988
100,000 5,000 7,500 3,750 10,500 5,250
105,000 5,250 7,875 3,938 11,025 5,513
110,000 5,500 8,250 4,125 11,550 5,775
115,000 5,750 8,625 4,313 12,075 6,038
120,000 6,000 9,000 4,500 12,600 6,300
125,000 6,250 9,375 4,688 13,125 6,563
130,000 6,500 9,750 4,875 13,650 6,825
135,000 6,750 10,125 5,063 14,175 7,088
140,000 7,000 10,500 5,250 14,700 7,350
145,000 7,250 10,875 5,438 15,225 7,613
150,000 7,500 11,250 5,625 15,750 7,875
155,000 7,750 11,625 5,813 16,275 8,138
160,000 8,000 12,000 6,000 16,800 8,400
165,000 8,250 12,375 6,188 17,325 8,663
170,000 8,500 12,750 6,375 17,850 8,925
175,000 8,750 13,125 6,563 18,375 9,188
180,000 9,000 13,500 6,750 18,900 9,450
185,000 9,250 13,875 6,938 19,425 9,713
190,000 9,500 14,250 7,125 19,950 9,975
195,000 9,750 14,625 7,313 20,475 10,238
200,000 10,000 15,000 7,500 21,000 10,500
205,000 10,250 15,375 7,688 21,525 10,763
210,000 10,500 15,750 7,875 22,050 11,025
215,000 10,750 16,125 8,063 22,575 11,288
220,000 11,000 16,500 8,250 23,100 11,550
225,000 11,250 16,857 8,438 23,625 11,813
230,000 11,500 17,250 8,625 24,150 12,075
1The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is 0.20 ACH.
2This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH.
17967 Hawksbill Dr., Lakeville
HVAC Load Calculations
for
Prepared By:
Thursday, May 23, 2024
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D.
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
West Metro Mechanical Inc.17967 Hawksbill Dr., Lakeville
Green Isle, MN 55338-2007 Page 2
Project Report
General Project Information
Project Title:17967 Hawksbill Dr., Lakeville
Project Date:Thursday, May 23, 2024
Design Data
Reference City:Minneapolis/St. Paul AP, Minnesota
Building Orientation:Front door faces East
Daily Temperature Range:Medium
Latitude:44 Degrees
Elevation:834 ft.
Altitude Factor:0.970
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter:-15 -11.42 n/a n/a 72 n/a
Summer:88 71 44%50%72 30
Check Figures
Total Building Supply CFM:1,042 CFM Per Square ft.:0.339
Square ft. of Room Area:3,072 Square ft. Per Ton:1,272
Volume (ft³):18,975
Building Loads
Total Heating Required Including Ventilation Air:49,525 Btuh 49.525 MBH
Total Sensible Gain:23,267 Btuh 80 %
Total Latent Gain:5,708 Btuh 20 %
Total Cooling Required Including Ventilation Air:28,975 Btuh 2.41 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\ ...\1431 142nd Ct. E., Rosemount Heat Calcs.r10 Thursday, May 23, 2024, 6:53 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
West Metro Mechanical Inc.17967 Hawksbill Dr., Lakeville
Green Isle, MN 55338-2007 Page 3
Miscellaneous Report
System 1
Input Data
Outdoor
Dry Bulb
Outdoor
Wet Bulb
Outdoor
Rel.Hum
Indoor
Rel.Hum
Indoor
Dry Bulb
Grains
Difference
Winter:-15 -11.42 100%n/a 72 n/a
Summer:88 71 44%50%72 29.99
Duct Sizing Inputs
Main Trunk Runouts
Calculate:Yes Yes
Use Schedule:Yes Yes
Roughness Factor:0.00300 0.01000
Pressure Drop:0.1000 in.wg./100 ft.0.1000 in.wg./100 ft.
Minimum Velocity:0 ft./min 0 ft./min
Maximum Velocity:900 ft./min 750 ft./min
Minimum Height:0 in.0 in.
Maximum Height:0 in.0 in.
Outside Air Data
Winter Summer
Infiltration Specified:0.370 AC/hr 0.190 AC/hr
117 CFM 60 CFM
Infiltration Actual:0.370 AC/hr 0.190 AC/hr
Above Grade Volume:Cu.ft.Cu.ft.X 18,975 X 18,975
7,021 Cu.ft./hr 3,605 Cu.ft./hr
X 0.0167 X 0.0167
Total Building Infiltration:117 CFM 60 CFM
Total Building Ventilation:150 CFM 150 CFM
---System 1---
Infiltration & Ventilation Sensible Gain Multiplier: 17.08 = (1.10 X 0.970 X 16.00 Summer Temp. Difference)
Infiltration & Ventilation Latent Gain Multiplier: 19.79 = (0.68 X 0.970 X 29.99 Grains Difference)
Infiltration & Ventilation Sensible Loss Multiplier: 92.85 = (1.10 X 0.970 X 87.00 Winter Temp. Difference)
Winter Infiltration Specified:0.370 AC/hr (117 CFM), Construction: Average
Summer Infiltration Specified:0.190 AC/hr (60 CFM), Construction: Average
C:\ ...\1431 142nd Ct. E., Rosemount Heat Calcs.r10 Thursday, May 23, 2024, 6:53 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
West Metro Mechanical Inc.17967 Hawksbill Dr., Lakeville
Green Isle, MN 55338-2007 Page 4
Load Preview Report
Scope
Net
Ton
ft.²
/Ton Area
Sen
Gain
Lat
Gain
Net
Gain
Sen
Loss
Sys
Htg
CFM
Sys
Clg
CFM
Sys
Act
CFM
Duct
Size
Building 2.41 1,272 3,072 23,267 5,708 28,975 49,525 588 1,042 1,042
System 1 2.41 1,272 3,072 23,267 5,708 28,975 49,525 588 1,042 1,042 12x15
Ventilation 1,025 2,968 3,993 5,571 150 150 150
Zone 1 3,072 22,242 2,740 24,982 43,954 588 1,042 1,042 12x15
1-Basement 996 1,005 82 1,087 9,791 131 47 47 1--5
2-Main Level 996 10,559 1,001 11,560 18,752 251 495 495 5--7
3-2nd Story 1,080 10,678 1,657 12,335 15,411 206 500 500 5--7
C:\ ...\1431 142nd Ct. E., Rosemount Heat Calcs.r10 Thursday, May 23, 2024, 6:53 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
West Metro Mechanical Inc.17967 Hawksbill Dr., Lakeville
Green Isle, MN 55338-2007 Page 5
Duct Size Preview
Room or
Duct Name Source Minimum
Velocity
Maximum
Velocity
Rough.
Factor
Design
L/100
SP
Loss
Duct
Velocity
Duct
Length Htg
Flow
Clg
Flow
Act.
Flow
Duct
Size
Reg
Size
System 1
Supply Runouts
Zone 1
1-Basement Built-In 0 750 0.01 0.1 345.3 131 47 47 1--5
2-Main Level Built-In 0 750 0.01 0.1 370.2 251 495 495 5--7
3-2nd Story Built-In 0 750 0.01 0.1 374.4 206 500 500 5--7
Other Ducts in System 1
Supply Main Trunk Built-In 0 900 0.003 0.1 833.6 588 1,042 1,042 12x15
SummarySummarySummarySummarySummarySummarySummarySummary
System 1
Heating Flow:588
Cooling Flow:1042
C:\ ...\1431 142nd Ct. E., Rosemount Heat Calcs.r10 Thursday, May 23, 2024, 6:53 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
West Metro Mechanical Inc.17967 Hawksbill Dr., Lakeville
Green Isle, MN 55338-2007 Page 6
Total Building Summary Loads
Component
Description
Area
Quan
Sen
Loss
Lat
Gain
Sen
Gain
Total
Gain
Gls-Marvin: Glazing-Window, U-value 0.3, SHGC 0.34 313 8,169 0 10,584 10,584
11D: Door-Wood - Solid Core, U-value 0.39 39.7 1,346 0 418 418
15B0-10sf-8: Wall-Basement, , R-10 board insulation to
floor, no interior finish, 8' floor depth, U-value 0.05,
above grade U-value 0.083
1288 5,929 0 118 118
12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud
cavity, no board insulation, siding finish, wood studs,
U-value 0.065
2266 12,814 0 2,400 2,400
16B-50: Roof/Ceiling-Under Attic with Insulation on Attic
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-50 insulation, U-value 0.02
1432 2,491 0 1,461 1,461
21A-20: Floor-Basement, Concrete slab, any thickness, 2
or more feet below grade, no insulation below floor,
any floor cover, shortest side of floor slab is 20' wide,
U-value 0.027
995.9 2,339 0 0 0
20P-30: Partition Floor (STD=84, WTD=0)-Over open
crawl space or garage, Passive, R-30 blanket
insulation, any cover, U-value 0.035
440 0 0 1,294 1,294
Subtotals for structure:33,088 0 16,275 16,275
People:4 800 920 1,720
Equipment:750 750 1,500
Lighting:200 682 682
Ductwork:0 0 0 0
Infiltration: Winter CFM: 117, Summer CFM: 60 10,866 1,190 1,026 2,216
Ventilation: Winter CFM: 150, Summer CFM: 150 5,571 2,968 1,025 3,993
Exhaust: Winter CFM: 150, Summer CFM: 150
AED Excursion:0 0 2,589 2,589
Total Building Load Totals:49,525 5,708 23,267 28,975
Check Figures
Total Building Supply CFM:1,042 CFM Per Square ft.:0.339
Square ft. of Room Area:3,072 Square ft. Per Ton:1,272
Volume (ft³):18,975
Building Loads
Total Heating Required Including Ventilation Air:49,525 Btuh 49.525 MBH
Total Sensible Gain:23,267 Btuh 80 %
Total Latent Gain:5,708 Btuh 20 %
Total Cooling Required Including Ventilation Air:28,975 Btuh 2.41 Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\ ...\1431 142nd Ct. E., Rosemount Heat Calcs.r10 Thursday, May 23, 2024, 6:53 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
West Metro Mechanical Inc.17967 Hawksbill Dr., Lakeville
Green Isle, MN 55338-2007 Page 7
Building Pie Chart
Building
Loss
49,525
Btuh
Floor 5%
Roof 5%
Wall 38%
Glass 16%
Door 3%
Infiltration 22%
Ventilation 11%
Building
Gain
28,975
Btuh
Floor 4%Roof 5%
Wall 9%
Glass 37%
Door 1%
People 6%
Equipment 5%
Lighting 2%
Infiltration 8%
Ventilation 14%
AED Excursion 9%
C:\ ...\1431 142nd Ct. E., Rosemount Heat Calcs.r10 Thursday, May 23, 2024, 6:53 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
West Metro Mechanical Inc.17967 Hawksbill Dr., Lakeville
Green Isle, MN 55338-2007 Page 8
Detailed Room Loads - Room 1 - Basement (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:33.0 ft.System Number:1
Room Width:30.2 ft.Zone Number:1
Area:995.9 sq.ft.Supply Air:47 CFM
Ceiling Height:8.8 ft.Supply Air Changes:0.3 AC/hr
Volume:8,715 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:1 Actual Winter Vent.:33 CFM
Runout Air:47 CFM Percent of Supply.:71 %
Runout Duct Size:5 in.Actual Summer Vent.:7 CFM
Runout Air Velocity:345 ft./min.Percent of Supply:14 %
Runout Air Velocity:345 ft./min.Actual Winter Infil.:8 CFM
Actual Loss:0.097 in.wg./100 ft.Actual Summer Infil.:4 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
N -Wall-15B0-10sf-8 33 X 8.8
- Abv. grade U-value 0.083
288.8 0.050 4.6 1,331 0.1 0 27
S -Wall-15B0-10sf-8 33 X 8.8
- Abv. grade U-value 0.083
288.8 0.050 4.6 1,331 0.1 0 27
E -Wall-15B0-10sf-8 44 X 8.8
- Abv. grade U-value 0.083
385 0.050 4.6 1,774 0.1 0 36
W -Wall-15B0-10sf-8 34 X 8.8
- Abv. grade U-value 0.083
297.5 0.050 4.6 1,371 0.1 0 28
W -Wall-12F-0sw 8 X 5.2 24.5 0.065 5.7 139 1.1 0 26
W -Wall-15B0-10sf-8 8 X 3.5
- Abv. grade U-value 0.083
28 0.050 4.4 122 0.0 0 0
W -Wall-12F-0sw 7 X 4.6 32.1 0.065 5.7 181 1.1 0 34
W -Gls-Gls-Marvin shgc-0.34 0%S 17.5 0.300 26.1 457 36.6 0 640
Floor-21A-20 30.2 X 33 995.9 0.027 2.3 2,339 0.0 0 0
Subtotals for Structure:9,045 0 818
Infil.: Win.: 8.0, Sum.: 4.1 187 3.979 746 0.373 82 70
AED Excursion:117
Room Totals:9,791 82 1,005
C:\ ...\1431 142nd Ct. E., Rosemount Heat Calcs.r10 Thursday, May 23, 2024, 6:53 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
West Metro Mechanical Inc.17967 Hawksbill Dr., Lakeville
Green Isle, MN 55338-2007 Page 9
Detailed Room Loads - Room 2 - Main Level (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:33.0 ft.System Number:1
Room Width:30.2 ft.Zone Number:1
Area:995.9 sq.ft.Supply Air:495 CFM
Ceiling Height:9.1 ft.Supply Air Changes:3.3 AC/hr
Volume:9,046 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:5 Actual Winter Vent.:64 CFM
Runout Air:99 CFM Percent of Supply.:13 %
Runout Duct Size:7 in.Actual Summer Vent.:71 CFM
Runout Air Velocity:370 ft./min.Percent of Supply:14 %
Runout Air Velocity:370 ft./min.Actual Winter Infil.:59 CFM
Actual Loss:0.070 in.wg./100 ft.Actual Summer Infil.:30 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
N -Wall-12F-0sw 42 X 9.1 344.8 0.065 5.7 1,950 1.1 0 365
S -Wall-12F-0sw 42 X 9.1 348.5 0.065 5.7 1,971 1.1 0 369
E -Wall-12F-0sw 34 X 9.1 308.8 0.065 5.7 1,746 1.1 0 327
W -Wall-12F-0sw 34 X 9.1 156.8 0.065 5.7 887 1.1 0 166
N -Door-11D 2.7 X 7 18.7 0.390 33.9 633 10.5 0 197
S -Door-11D 3 X 7 21 0.390 33.9 713 10.5 0 221
N -Gls-Gls-Marvin shgc-0.34 100%S 18 0.300 26.1 470 11.2 0 202
S -Gls-Gls-Marvin shgc-0.34 0%S 12 0.300 26.1 313 20.3 0 243
W -Gls-Gls-Marvin shgc-0.34 0%S 48 0.300 26.1 1,253 36.6 0 1,756
W -Gls-Gls-Marvin shgc-0.34 0%S 24 0.300 26.1 626 36.6 0 878
W -Gls-Gls-Marvin shgc-0.34 0%S
(2)
48 0.300 26.1 1,252 36.6 0 1,756
W -Gls-Gls-Marvin shgc-0.34 0%S 32 0.300 26.1 835 36.6 0 1,171
UP-Ceil-16B-50 22 X 16 352 0.020 1.7 612 1.0 0 359
Subtotals for Structure:13,261 0 8,010
Infil.: Win.: 59.1, Sum.: 30.4 1,381 3.977 5,491 0.376 601 519
AED Excursion:1,229
People: 200 lat/per, 230 sen/per:2 400 460
Lighting:100 341
Room Totals:18,752 1,001 10,559
C:\ ...\1431 142nd Ct. E., Rosemount Heat Calcs.r10 Thursday, May 23, 2024, 6:53 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
West Metro Mechanical Inc.17967 Hawksbill Dr., Lakeville
Green Isle, MN 55338-2007 Page 10
Detailed Room Loads - Room 3 - 2nd Story (Average Load Procedure)
General
Calculation Mode:Htg. & clg.Occurrences:1
Room Length:36.0 ft.System Number:1
Room Width:30.0 ft.Zone Number:1
Area:1,080.0 sq.ft.Supply Air:500 CFM
Ceiling Height:8.1 ft.Supply Air Changes:3.4 AC/hr
Volume:8,730 cu.ft.Req. Vent. Clg:0 CFM
Number of Registers:5 Actual Winter Vent.:53 CFM
Runout Air:100 CFM Percent of Supply.:11 %
Runout Duct Size:7 in.Actual Summer Vent.:72 CFM
Runout Air Velocity:374 ft./min.Percent of Supply:14 %
Runout Air Velocity:374 ft./min.Actual Winter Infil.:50 CFM
Actual Loss:0.072 in.wg./100 ft.Actual Summer Infil.:26 CFM
Item
Description
Area
Quantity
-U-
Value
Htg
HTM
Sen
Loss
Clg
HTM
Lat
Gain
Sen
Gain
N -Wall-12F-0sw 44 X 8.1 355.7 0.065 5.7 2,011 1.1 0 377
S -Wall-12F-0sw 44 X 8.1 342.4 0.065 5.7 1,936 1.1 0 363
E -Wall-12F-0sw 30 X 8.1 186.2 0.065 5.7 1,053 1.1 0 197
W -Wall-12F-0sw 26 X 8.1 166.2 0.065 5.7 940 1.1 0 176
S -Gls-Gls-Marvin shgc-0.34 0%S 7 0.300 26.1 183 20.3 0 142
S -Gls-Gls-Marvin shgc-0.34 0%S 6.2 0.300 26.1 163 20.3 0 127
E -Gls-Gls-Marvin shgc-0.34 0%S 6.2 0.300 26.1 163 36.6 0 229
E -Gls-Gls-Marvin shgc-0.34 0%S
(2)
50 0.300 26.1 1,306 36.6 0 1,830
W -Gls-Gls-Marvin shgc-0.34 0%S 24 0.300 26.1 626 36.6 0 878
W -Gls-Gls-Marvin shgc-0.34 0%S 20 0.300 26.1 522 36.6 0 732
UP-Ceil-16B-50 36 X 30 1080 0.020 1.7 1,879 1.0 0 1,102
Floor-Part-20P-30 20 X 22 440 0.035 0.0 0 2.9 0 1,294
Subtotals for Structure:10,782 0 7,447
Infil.: Win.: 49.9, Sum.: 25.6 1,164 3.977 4,629 0.375 507 437
AED Excursion:1,243
People: 200 lat/per, 230 sen/per:2 400 460
Equipment:750 750
Lighting:100 341
Room Totals:15,411 1,657 10,678
Equipment Cooling Loads
Item Name
Cont.
Output
Sens.
Btuh
Cont.
Output
Lat.
Btuh
Avg.
In-Use
Output
Pct
Used
/Hour
Sens.
Load
Btuh
Lat.
Load
Btuh
Entertainment Equipment 750 750 100 100 750 750
Total 750 750
C:\ ...\1431 142nd Ct. E., Rosemount Heat Calcs.r10 Thursday, May 23, 2024, 6:53 PM
Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.
West Metro Mechanical Inc.17967 Hawksbill Dr., Lakeville
Green Isle, MN 55338-2007 Page 11
System 1 Room Load Summary
No
Room
Name
Area
SF
Htg
Sens
Btuh
Min
Htg
CFM
Run
Duct
Size
Run
Duct
Vel
Clg
Sens
Btuh
Clg
Lat
Btuh
Min
Clg
CFM
Act
Sys
CFM
---Zone 1---
1 Basement 996 9,791 131 1-5 345 1,005 82 47 47
2 Main Level 996 18,752 251 5-7 370 10,559 1,001 495 495
3 2nd Story 1,080 15,411 206 5-7 374 10,678 1,657 500 500
Ventilation 5,571 1,025 2,968
System 1 total 3,072 49,525 588 23,267 5,708 1,042 1,042
System 1 Main Trunk Size:12x15 in.
Velocity:834 ft./min
Loss per 100 ft.:0.105 in.wg
Cooling System Summary
Cooling
Tons
Sensible/Latent
Split
Sensible
Btuh
Latent
Btuh
Total
Btuh
Net Required:2.41 80% / 20%23,267 5,708 28,975
Equipment Data
Heating System Cooling System
Type:Natural Gas Furnace Standard Air Conditioner
Model:
Indoor Model:
Brand:
Efficiency:0 AFUE 0 SEER
Sound:0 0
Capacity:0 Btuh 0 Btuh
Sensible Capacity:n/a 0 Btuh
Latent Capacity:n/a 0 Btuh
C:\ ...\1431 142nd Ct. E., Rosemount Heat Calcs.r10 Thursday, May 23, 2024, 6:53 PM
Passive (No Fan)
Active (With fan and monitoring
device )
Location (or future location) of Fan:
Other Please Describe Here
Not applicable, all ducts located in conditioned space
Not required per mech. code
Passive
Powered
Interlocked with exhaust device.
Describe:
Input in
BTUS:
Capacity in
Gallons:
Other, describe:
AFUE or
HSPF%
Cfm's
" round duct OR
" metal duct
Not required per mech. code
Passive
Low: Other, describe:
Low:
Location of fan(s), describe: Cfm's
" round duct OR
" metal duct
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.
New Construction Energy Code Compliance Certificate
Name of Residential Contractor MN License Number
City Mailing Address of the Dwelling or Dwelling Unit
Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms:
Energy Recover Ventilator (ERV) Capacity in cfms:
Combustion Air Select a Type
Location of duct or system:
Rim Joist (2nd Floor+)
Building envelope air tightness:
Below Entire Slab
Fuel Type
Solar Heat Gain Coefficient (SHGC):
Windows & Doors
Ceiling, vaulted
Bay Windows or cantilevered areas
Floors over unconditioned area
THERMAL ENVELOPE
Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade
RADON CONTROL SYSTEM
Total R-Value of all Types of InsulationType: Check All That Apply
Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas
Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall
Output
in Tons:
Appliances Cooling System
Location of duct or system:
Heating or Cooling Ducts Outside Conditioned Spaces
Make-up Air Select a Type
Domestic Water
Heater
Model
Heating System
Rim Joist (1st Floor)
Average U-Factor (excludes skylights and one door ) U:
Duct system air tightness:
Rating or Size
Efficiency
Heating Gain Cooling Load
Select Type
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
Residential Load
Calculation
SEER
/EER
Capacity continuous ventilation rate in cfms:
Heating Loss
Manufacturer
Total ventilation (intermittent + continuous) rate in cfms:
Balanced Ventilation capacity in cfms:
High:
High:
MECHANICAL VENTILATION SYSTEM
Date Cert. Posted
R-value
MECHANICAL SYSTEMS
Builders Associaton of Minnesota version 101014
7/9/24 X PM