HomeMy WebLinkAboutLA225412-18348 Glacier Way-Permit PackRESIDENTIAL BUILDING
PERMIT APPLICATION
CITY OF LAKEVILLE
BUILDING INSPECTIONS DEPARTMENT
20195 HOLYOKE AVENUE
LAKEVILLE, MN 55044
952-985-4440
Office Use Only
__________________
Permit Number
___________________
Received By
___________________
Date Received
___________________
Fee Total
SITE ADDRESS:
MAILING ADDRESS: CITY: STATE: ZIP:
JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________
LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________
ESTIMATED VALUATION: PROPOSED START DATE: END DATE:
(New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION:
APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL
NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED)
PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License)
RESIDENT OWNER
NAME:_______________________________________________________________________________
HOME PHONE #:_____________________________ CELL PHONE:___________________________
GENERAL CONTRACTOR
Homeowner
Contractor
CONTRACTOR:_______________________________________________________________________
LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE)
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
PLUMBING WORK
Homeowner
Contractor
CONTRACTOR:__________________________________________LICENSE #: PM______________
OFFICE PHONE #:_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
MECHANICAL WORK
Homeowner
Contractor
CONTRACTOR:________________________________________ _______________________________
_____________________________ CELL PHONE:___________________________
ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________
BOND #:_______________________________________ EXPIRATION DATE____________________
SEWER/WATER CONTRACTOR
New Construction Only
NAME:________________________________________________ ______________________________
_____________________________ CELL PHONE:______________________________
BOND #:_______________________________________ EXPIRATION DATE____________________
NAME OF APPLICANT (Please Print)DATE
I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS
APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO
COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH
LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED
PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE
CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE
ESCROW APPLICATION AND REFUND.
OFFICE PHONE #:_
OFFICE PHONE #:_
*Entering your name affirms your intent to comply with the statement above.
*
Submit Application To: permits@lakevillemn.gov
RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT
CONDO
REROOF
RESIDE
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES
LOWER LEVEL FINISH
ADDITION
FOUNDATION ONLY
MISCELLANEOUS
DEMO
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
CITY BUILDING VALUATION: $
BUILDING PERMIT FEES
$PERMIT FEE
$PLAN CHECK
$SURCHARGE
$METRO SAC
$CITY WATER HOOKUP UNIT
$CITY SEWER HOOKUP UNIT
$LANDSCAPE ESCROW
$TREE ESCROW
$MISC ESCROW
$PLUMBING
$MECHANICAL
$SEWER WATER
WATER METER
PRESSURE REDUCING VALVE
$OTHER
$TOTAL
METER SIZE
PRESSURE REDUCING VALVE
SEWER/WATER
SEWER/WATER
FINAL
STREET DRAINTILE
BUILDING INFORMATION
TYPE OF CONSTRUCTION
ZONING
CODE EDITION
FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
MECHANICAL
AIR TEST
FINAL
ROUGH-IN
PLUMBING
FINAL
ROUGH-IN
INSULATION
LATH
DECK FOOTING
FIREPLACE
FOOTING
FOUNDATION
FRAMING
PORCH FRAMING
PORCH FOOTING
POURED WALL
SITE
LOWER LEVEL FINAL
OTHER
DECK FRAMING
LOWER LEVEL FRAMING
LANDSCAPING
DECK FINAL
$
$
ACCESSORY BUILDING
EGRESS WINDOW
UNDERGROUND
MAIN FLOOR6' -7 3/8"MAIN PLATE14' -8 1/2"LOWER FLOOR-3' -2 1/2"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"LOWER PLATE4' -10 5/8"FOYER FLOOR1' -2 1/8"GARAGE PLATE9' -3 1/4"GARAGE PLATE9' -3 1/4"MAIN FLOOR PLATE HEIGHT8' - 1 1/8"LOWER FLOOR PLATE HEIGHT8' - 1 1/8"ALUMINUM SOFFIT& FASCIA TYP.VINYL LAP SIDINGCULTURED STONE W/ CONCRETE CAPSEE COLUMN DETAILSHEET A-502UPPER FLOOR11' -0"UPPER PLATE19' -1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"FOYER PLATE HEIGHT8' - 1 1/8"VINYL BOARD& BATTEN TYP.4" SMARTSIDE WINDOW TRIM, SIDES & BOTTOM6" WINDOW TRIM ON TOP W/ 2" EXTENSION 6" SMARTSIDE FRIEZE BOARD 6" SMARTSIDE STORY BOARD ARCHEDSMARTSIDE SOFFIT 4" VINYL CORNERS1' - 0"0' - 3"4" SMARTSIDE TRIM@ WINDOWS & DOORS FRONT TYP. ADDRESS STONE6" / 12"6" / 12"6" / 12"8" 12"4" / 12"6" / 12"GARAGE PLATE HEIGHT9' - 3 1/4"FRONT ELEVATION SQFTFRONT ELEVATION= 675 SQ FT.LAP SIDING SQFT.= 317 SQ FT.BOARD & BATTEN SQFT. = 104 SQ FT.STONE SQFT. = 18 SQ FT. LAP SIDING PERCENT OF TOTAL= 46%3' - 6"8" 12"24" RETURNS TYP. 4" 12"6" 12"4" 12"6" 12"8" / 12"24" RETURNSTYP.6" 12"6" 12"6" 12"4" 12"8" / 12"VINYL SIDING& CORNERS TYP.ALUMINUM SOFFIT& FASCIA TYP.6" / 12"4" / 12"8" 12"6" / 12"1/4" = 1'-0"A-2011FRONT ELEVATION1/8" = 1'-0"A-2012LEFT ELEVATIONDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:6/28/2024 12:50:21 PMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-201OTT4534.26.24 CB554126410116.28.24 CB4.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINE1/8" = 1'-0"A-2013RIGHT ELEVATION1/8" = 1'-0"A-2014REAR ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONSA-401 FOUNDATIONA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 ROOF/ SECTIONA-502 DETAILSA-503 WINDOW/ DETAILSSecure door closed until deck isconstructed with a separate permit.Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode07/10/2024jnuetzman
*ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATION2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE2'-10"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.24' - 2"25' - 6"49' - 8"22' - 2"2' - 0"26' - 4"49' - 8"15' - 6"34' - 2"27' - 0"7' - 2"3' - 10"11' - 8"10' - 0"19' - 2"7' - 6"14' - 4"29' - 2"21' - 10"51' - 0"0' - 10 1/2"8' - 3" M.O.0' - 10 1/2"1' - 5 1/2"16' - 3" M.O.1' - 5 1/2"21' - 4"8' - 4"14' - 4"15' - 6"7' - 10"19' - 4"2' - 7 1/4"3' - 8 3/4"3' - 8 3/4"14' - 7 1/4"14' - 9 3/4"7' - 8 1/4"4' - 6"2A-5012x4 STUDS @ 16" O.C. ONHALF-HIGH 4" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.3'-6"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"4' - 1 3/4"22' - 2 1/4"7' - 0"44' - 0"51' - 0"42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY3' - 9 1/4"7' - 9 1/2"2' - 9 1/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:6/28/2024 12:50:22 PMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-401OTT4534.26.24 CB554126410116.28.24 CB4.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINE1/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.
UNEXCAVATEDUNEXCAVATEDSUMPFURNACEF. D.W. H.BATH11' - 8"3' - 10"7' - 2"27' - 0"CO DET.SMOKEDET.7' - 8"6' - 8"15' - 6"34' - 2"49' - 8"51' - 0"29' - 2"21' - 10"10' - 0"19' - 2"7' - 6"14' - 4"49' - 8"24' - 2"25' - 6"INSULATE BETWEENWALL & SLAB11 7/8" LSL JOISTS@ 16" O.C.23' - 10 1/4"5' - 4 1/2"4' - 2 1/4"5' - 1"5' - 6"SMOKEDET.AIR EX.22' - 2"2' - 0"15' - 6"7' - 10"21' - 4"8' - 4"22' - 2"3' - 6"3' - 6"14' - 10"4' - 10"3' - 8"17' - 10"12' - 0"4' - 0"0' - 4"6' - 0" B.W.P.6' - 0" B.W.P.3' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.2-9 1/2" LVL W/ 2 TRIMMERS2-2x1024" CANT.ABOVE12/4 x 6/8R.O. 2' -6" x 6' -11"2' - 8" B.W.P.2-2x10 51' - 0"2-2x10 6' - 2"19' - 10"9' - 4"2' - 0"1' - 8"6' - 4"2' - 10"42/8 x 6/8R.O. 2' -10" x 6' -11"MECHANICALLAUNDRY3' - 0" B.W.P.12' - 0"5' - 0"17' - 2"FAMILY ROOMBEDROOM #4BEDROOM #511' - 0"5' - 0"11' - 0"12/4 x 6/8R.O. 2' -6" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"4' - 0" B.W.P.2-9 1/2" LVL W/ 2 TRIMMERS8' - 10 1/2"9' - 8 1/2"17' - 11"7' - 6"7' - 0"44' - 0"2-9 1/2" LVL W/ 2 TRIMMERS2x4 STUDS @ 16" O.C. ONHALF-HIGH 4" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.WS2x64' VANITY0' - 4"29' - 8"26' - 0"2-2x10 2-2x1042/8 x 6/8R.O. 2' -10" x 6' -11"WALL BUILTTO BOTTOM OF WINDOW1' - 0"4' - 2"2-9 1/2" LSLW/ 2 TRIMMERS2-2x10 EQEQ*ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE/ SHEATHINGNOT INSULATION20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACINGCRAWL SPACE12" CANT. ABOVE 2-2x10 95040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"1367640 NVGER.O. 7' -6" x 4' -0"H.H. 6' -10"22036 NVH1R.O. 2' -0" x 3' -6"H.H. 6' -10"117636 NVGER.O. 7' -6" x 3' -6"H.H. 6' -10"42/8 x 6/8R.O. 2' -10" x 6' -11"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESSMOKEDET.12/4 x 6/8R.O. 2' -6" x 6' -11"R & SHR & SHCLOSETCLOSETSET FIREPLACE 12" A.F.F. W/ TILE SURROUND AND MANTELTECH TUBE ABOVE 1' - 4 1/2"36" GAS F.P.5' - 0"SINKWASHERDRYER96/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"5' TUB/SHWRSTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.1/4" = 1'-0"A-4021LOWER FLOOR PLANDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:6/28/2024 12:50:23 PMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-402OTT4534.26.24 CB554126410116.28.24 CB4.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINE-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).BWPsAboveFAN
29' - 2"21' - 10"51' - 0"10' - 0"19' - 2"7' - 6"14' - 4"51' - 8"2' - 0"27' - 0"7' - 0"11' - 8"4' - 0"FOYERBEDROOM #2HALLDININGKITCHENGARAGESTOOP1' - 0"8' - 0"1' - 0"1' - 7"16' - 0"1' - 7"KNEE WALL W/14" SPINDLES 4' - 7 1/2"3' - 4 1/2"4' - 0"7' - 4"3' - 0"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. CEILING1/2" GYP. BD. ON GARAGE WALLSR-38 MIN. INSULATION IN FLOOR ABOVEGARAGE PLATE HEIGHT TO MATCHFOYER PLATE HEIGHT UNLESS NOTED OTHERWISECO DET.SMOKEDET.2-2x10SEE COLUMN DETAILSHEET A-50224' - 2"27' - 6"2' - 0"25' - 6"22' - 2"2' - 0"0' - 6"7' - 0"0' - 6"3' - 6"5' - 0"21' - 0"2-14" LVLFLOOR LINE ABOVE20" FLOOR TRUSSESPER MFG. SPACINGATTICACCESS2' - 8" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.6' - 0" B.W.P.PFH BRACEDWALL PANEL3' - 0" B.W.P.2-2x10 W/ 2 TRIMMERS2A-50129' - 5 3/4"2' - 6"12' - 0 1/4"GIRDER TRUSS 5x5 PSL5x5 PSL3' - 0" B.W.P.8' - 6"5' - 8"8' - 8"8' - 8"5' - 5 1/4"7' - 0 3/4"14' - 2"17' - 4"12' - 6"7' - 0"44' - 0"22' - 2"3' - 6"3' - 6"14' - 10"21' - 8"8' - 0"32/6 x 6/8R.O. 2' -8" x 6' -11"R & SH51' - 0"17' - 6"1' - 8"5' - 0"11' - 10"2-9 1/2" LSL FLUSH2-9 1/2" LSL FLUSH2-9 1/2" LSL 6' - 8 1/4"20' - 3 3/4"3' - 3"3' - 9"3' - 0" B.W.P.51' - 8"1116' x 8' O.H. GARAGE DOOR6' - 4"1' - 8"2-2x1036' - 0"15' - 8"GIRDER FLOOR TRUSSTRIANGLE OPENING W/ RAILING BETWEEN STAIRS 108' x 8' O.H. GARAGE DOORSMOKEDET.26' - 0"8' - 0"SINK3' - 6"3' - 9"96/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"13' - 0 3/4"3' - 7 3/4"9' - 3 1/2"BEDROOM #3LIVING ROOMDW4' - 0"7' - 0"TYP0' - 4 1/2"85/0 x 6/8R.O. 5' -2" x 6' -11"4' - 6 1/2"BOTTOM OF WINDOW FRAMED 42" A.F.F.2-2x10 CONT.3-2x102-2x1085/0 x 6/8R.O. 5' -2" x 6' -11"R & SH32/6 x 6/8R.O. 2' -8" x 6' -11"R & SH2x6VAULTVAULT LINEVAULTFLAT3:123:12THIS WALL TO BE BALLOON FRAMEDINTO SCISSOR TRUSS ABOVE 2' - 8" B.W.P.3' - 8"4' - 0"5' - 3 1/2"3' - 10"14' - 10 1/2"1' - 0"3' - 8"3' - 8"5' VANITY5' TUB/SHWRFACE FRAME LINEN OVER ENTRY CLOSET18" DEEP36" REFCABINET SURROUND ON REFRIGERATOR 4A-503VAULTFLAT2-2x10 W/ 2 TRIMMERS2-2x102-2x10MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.BATH4-2x611' - 5 1/2"2' - 6"5' - 4 1/2"2' - 8 1/4"7' - 4 3/4"2' - 10"553640 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 6' -0"H.H. 6' -10"595040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"95040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"75020 NVPWGR.O. 5' -0" x 2' -0"H.H. 7' -0"43060 NVH2 ER.O. 6' -0" x 6' -0"H.H. 6' -10"32/6 x 6/8R.O. 2' -8" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"52/8 x 6/8 FIRE RATEDR.O. 2' -10 1/4" x 6' -11"95040E NVG1R.O. 5' -0" x 4' -0"H.H. 7' -6"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESPFH1' - 7"PFH1' - 7"3' - 0" B.W.P.2' - 8" B.W.P.TRASH ROLL OUT 63/0 x 6/8 W/ 12" D.S. SLTEMPERED GLASS @ LOWER SASHES OVEN /MICRO12/4 x 6/8R.O. 2' -6" x 6' -11"16" SHELVING5' - 0"36" COOKTOP W/ WOOD HOOD ABOVE 2' - 9 1/32"PAN.ELONGATED CONC. PAD4' - 0" B.W.P.B.W.P.4' - 0"1' - 0"GIRDER TRUSS4-2x63-11 7/8" LVL1/4" = 1'-0"A-4031MAIN FLOOR PLANDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:6/28/2024 12:50:25 PMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-403OTT4534.26.24 CB554126410116.28.24 CB4.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINE-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).BWPsAboveVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.FANSmoke
EN SUITEPRIMARY SUITEBOX VAULT11' - 1"11' - 1"CO DET.SMOKEDET.SMOKEDET.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.22/4 x 6/8 PKTR.O. 4' -10" x 6' -11"MFG. ROOF TRUSSES@ 24" O.C.2A-50122' - 2"7' - 6"42/8 x 6/8R.O. 2' -10" x 6' -11"19' - 2 1/4"2' - 11 3/4"2x6TYP.2' - 0"3' - 6"4' - 0"29' - 8"6' - 8"5' - 1"4' - 1"2' - 0"4' - 4"5' - 2"9' - 4"2' - 8"20' - 8"5' - 0"1' - 0"1' - 10"14' - 4"LANDINGVAULT FLAT18' - 7 1/2"3' - 6 1/2"22' - 2"8' - 4"17' - 2"ATTICACCESS22' - 2"3' - 6"3' - 6"14' - 10"5' - 0"R&SHHEAD12/4 x 6/8R.O. 2' -6" x 6' -11"2-2x102-2x10 W/ 2 TRIMMERSTILE SHOWERKNEE WALL W/14" SPINDLES SHAMPOO SHELFSEATDOUBLE FRAMED PLUMBING WALL2-2x102-2x102-2x10VAULTFLATVAULT LINE3:123:126' - 8 3/4"3' - 4"12' - 1 1/4"3' x 5' TUB W/ TILEDECK12/4 x 6/8R.O. 2' -6" x 6' -11"DBL R&SH2' - 4"48" WALL W/ GLASS PANEL5'-6" VANITY1' - 10"4A-5031'-6" LINENCONTROLVAULTFLATMFG. ROOF TRUSSES@ 24" O.C.CLOSET33016 NVA1 TEMP.R.O. 3' -0" x 1' -6"H.H. 6' -10"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"64030 NVPWGR.O. 4' -0" x 3' -0"H.H. 6' -10"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES78" TILE WALL HEIGHT TYP. 127646 NVGER.O. 7' -6" x 4' -6"H.H. 6' -10"74/0 x 6/8 BYPASSR.O. 4' -2" x 6' -11"COMFORT HEIGHT, ELONGATED DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:6/28/2024 12:50:26 PMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-404OTT4534.26.24 CB554126410116.28.24 CB4.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINE1/4" = 1'-0"A-4041UPPER FLOOR PLAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).FANFANTemper ifwithin 60"of tub floor
STANDARD ENERGY HEELS @ 4:12 6:12 & 8:12 FASCIA LINES TO MATCH18" OVERHANGS & 12" RAKES TYP.ROOF VENT (10) PER CODE (2) ROOF VENTS THIS AREA (3) ROOF VENTS IN THIS AREA (5) ROOF VENTS IN THIS AREA 4" / 12"8" / 12"6" / 12"6" / 12"6" / 12"8" / 12"4" / 12"6" / 12"6" / 12"6" / 12"6" / 12"8" / 12"8" / 12"MAIN FLOOR6' -7 3/8"MAIN PLATE14' -8 1/2"LOWER FLOOR-3' -2 1/2"T.O. TYP FOOTING-3' -6"T.O. FOUNDATION0' -0"LOWER PLATE4' -10 5/8"FOYER FLOOR1' -2 1/8"GARAGE PLATE9' -3 1/4"UPPER FLOOR11' -0"UPPER PLATE19' -1 1/8"CRAWL SPACEFOYERMAIN PLATE HEIGHT8' - 1 1/8"MFG. ROOF TRUSSES@ 24" O.C.7 RISERS 4' - 4 5/8"9 RISERS 5' - 5 1/4"7 RISERS4' - 4 5/8"11 7/8" LSL JOISTSBATHLANDINGUPPER PLATE HEIGHT8' - 1 1/8"FOYER PLATE HEIGHT8' - 1 1/8"20" FLOOR TRUSSES 20" FLOOR TRUSSES LOWER FLOOR PLATE HEIGHT8' - 1 1/8"LIVING ROOM3" 12"6" 12"4" 12"6" 12"DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:6/28/2024 12:50:27 PMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-501OTT4534.26.24 CB554126410116.28.24 CB4.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINE1/8" = 1'-0"A-5011ROOF PLAN1/4" = 1'-0"A-5012SECTION3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:
ANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATION2" FOAMBOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLVERIFY FLOOR SYSTEMWITH FLOOR PLANS0' - 8"6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATION2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 BLOWINSULATION MIN.FLOOR TRUSSWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHING0' - 10"1x61x6SMOOTHSMARTSIDETYPICAL4x4COREPOST4x4 POSTFRAMING0' - 10"0' - 10"VERIFY FLOOR SYSTEMWITH FLOOR PLANSLOWER FLOOR PLATE HEIGHT8' - 1 1/8"RIM JOISTWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)INSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS4" DRAIN TILE W/WEEP FROM BLOCKTOP COURSE TO BE SOLID BLOCK,BOND BEAM OR GROUTED SOLID 6 MIL. V.B.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEARCHITECTURAL ASPHALT SHINGLES W/ 15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGE3/4" T&GSUBFLOORR-20 SPRAYFOAM INSULATION6 MIL. V.B.1/2" GYP. BD.6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAP5/8" GYP. BD.MAIN FLOOR PLATE HEIGHT8' - 1 1/8"SIDING PER PLANSDRYVIT INSULATION PROTECTION SIDING TO6" BELOW GRADEDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:6/28/2024 12:50:28 PMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-502OTT4534.26.24 CB554126410116.28.24 CB4.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINE1/2" = 1'-0"A-5023TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5024TYP. WALKOUT SECTION1/2" = 1'-0"A-5026TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5027BEARING WALL SECTION1/2" = 1'-0"A-5022GARAGE CEILING1/2" = 1'-0"A-5021TYP. LOOKOUT SECTION1/2" = 1'-0"A-5025TYP. COLUMN1/2" = 1'-0"A-5028TYP. WALL SECTION
FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALMAIN FLOOR6' -7 3/8"MAIN FLOOR6' -7 3/8"MAIN PLATE14' -8 1/2"LOWER PLATE4' -10 5/8"FOYER FLOOR1' -2 1/8"GARAGE PLATE9' -3 1/4"UPPER FLOOR11' -0"UPPER PLATE19' -1 1/8"BATHFOYERMECHANICALFACE FRAME LINEN OVER ENTRY CLOSET18" DEEP4' - 4 5/8"3' - 8 1/2"ENTRY CLOSET LANDING2' - 11 3/4"20" FLOOR TRUSSES 20" FLOOR TRUSSES 8' - 1 1/8"8' - 1 1/8"8' - 1 1/8"DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:6/28/2024 12:50:29 PMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-503OTT4534.26.24 CB554126410116.28.24 CB4.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINEWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 VECTOR ENVISION SERIES 2 2020 NVA1 2' - 0" 2' - 0" 6' - 10"2 VECTOR ENVISION SERIES 1 2036 NVH1 2' - 0" 3' - 6" 6' - 10"3 VECTOR ENVISION SERIES 1 3016 NVA1 TEMP. 3' - 0" 1' - 6" 6' - 10"4 VECTOR ENVISION SERIES 1 3060 NVH2 E 6' - 0" 6' - 0" 6' - 10"5 VECTOR ENVISION SERIES 3 3640 NVPWG/3620 NVA1 TEMP. 3' - 6" 6' - 0" 6' - 10"6 VECTOR ENVISION SERIES 1 4030 NVPWG 4' - 0" 3' - 0" 6' - 10"7 VECTOR ENVISION SERIES 1 5020 NVPWG 5' - 0" 2' - 0" 7' - 0"9 VECTOR ENVISION SERIES 4 5040E NVG1 5' - 0" 4' - 0" VARIES11 VECTOR ENVISION SERIES 1 7636 NVGE 7' - 6" 3' - 6" 6' - 10"136 VECTOR ENVISION SERIES 1 7640 NVGE 7' - 6" 4' - 0" 6' - 10"12 VECTOR ENVISION SERIES 1 7646 NVGE 7' - 6" 4' - 6" 6' - 10"3/8" = 1'-0"A-5033METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/4" = 1'-0"A-5034LINEN SECTIONDOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH WIDTH COUNT COMMENTS1 2/4 x 6/8 2' - 6" 6' - 11" 72 2/4 x 6/8 PKT 4' - 10" 6' - 11" 13 2/6 x 6/8 2' - 8" 6' - 11" 34 2/8 x 6/8 2' - 10" 6' - 11" 65 2/8 x 6/8 FIRE RATED 2' - 10 1/4" 6' - 11" 16 3/0 x 6/8 W/ 12" D.S. SL 17 4/0 x 6/8 BYPASS 4' - 2" 6' - 11" 18 5/0 x 6/8 5' - 2" 6' - 11" 29 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 210 8' x 8' O.H. GARAGE DOOR 111 16' x 8' O.H. GARAGE DOOR 1ROOM FINISH SCHEDULEFLOOR ROOM NAME FLOOR FINISH AREA PLATE HEIGHT COMMENTSLOWER FLOOR CRAWL SPACE 120 SF 3' - 2 1/2"LOWER FLOOR BATH VINYL 52 SF 8' - 1 1/8" .LOWER FLOOR MECHANICAL 71 SF 8' - 1 1/8"LOWER FLOOR LAUNDRY VINYL 66 SF 8' - 1 1/8" .LOWER FLOOR FAMILY ROOM CARPET 433 SF 8' - 1 1/8" .LOWER FLOOR BEDROOM #4 CARPET 141 SF 8' - 1 1/8" .LOWER FLOOR BEDROOM #5 CARPET 134 SF 8' - 1 1/8" .LOWER FLOOR CLOSET CARPET 23 SF 8' - 1 1/8"LOWER FLOOR CLOSET CARPET 20 SF 8' - 1 1/8"FOYER FLOOR FOYER WOOD 89 SF 8' - 1 1/8" .FOYER FLOOR GARAGE 633 SF 9' - 3 1/4"FOYER FLOOR STOOP CONCRETE 30 SF 8' - 1 1/8" .FOYER FLOOR CONC. PAD 100 SF 8' - 1 1/8"MAIN FLOOR BEDROOM #2 CARPET 169 SF 8' - 1 1/8" .MAIN FLOOR HALL WOOD 59 SF 8' - 1 1/8" .MAIN FLOOR DINING WOOD 130 SF 8' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 184 SF 8' - 1 1/8" .MAIN FLOOR BATH VINYL 57 SF 8' - 1 1/8"MAIN FLOOR BEDROOM #3 CARPET 159 SF 8' - 1 1/8" .MAIN FLOOR LIVING ROOM WOOD 244 SF 8' - 1 1/8" .MAIN FLOOR PAN. 17 SF 8' - 1 1/8"UPPER FLOOR EN SUITE L.V.T 120 SF 8' - 1 1/8" .UPPER FLOOR PRIMARY SUITE CARPET 213 SF 8' - 1 1/8" BOX VAULTUPPER FLOOR CLOSET CARPET 69 SF 8' - 1 1/8" .UPPER FLOOR LANDING CARPET 87 SF 8' - 1 1/8"
MAIN FLOOR6' -7 3/8"MAIN PLATE14' -8 1/2"LOWER FLOOR-3' -2 1/2"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"LOWER PLATE4' -10 5/8"FOYER FLOOR1' -2 1/8"GARAGE PLATE9' -3 1/4"GARAGE PLATE9' -3 1/4"MAIN FLOOR PLATE HEIGHT8' - 1 1/8"LOWER FLOOR PLATE HEIGHT8' - 1 1/8"ALUMINUM SOFFIT& FASCIA TYP.VINYL LAP SIDINGCULTURED STONE W/ CONCRETE CAPSEE COLUMN DETAILSHEET A-502UPPER FLOOR11' -0"UPPER PLATE19' -1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"FOYER PLATE HEIGHT8' - 1 1/8"VINYL BOARD& BATTEN TYP.4" SMARTSIDE WINDOW TRIM, SIDES & BOTTOM6" WINDOW TRIM ON TOP W/ 2" EXTENSION 6" SMARTSIDE FRIEZE BOARD 6" SMARTSIDE STORY BOARD ARCHEDSMARTSIDE SOFFIT 4" VINYL CORNERS1' - 0"0' - 3"4" SMARTSIDE TRIM@ WINDOWS & DOORS FRONT TYP. ADDRESS STONE6" / 12"6" / 12"6" / 12"8" 12"4" / 12"6" / 12"GARAGE PLATE HEIGHT9' - 3 1/4"FRONT ELEVATION SQFTFRONT ELEVATION= 675 SQ FT.LAP SIDING SQFT.= 317 SQ FT.BOARD & BATTEN SQFT. = 104 SQ FT.STONE SQFT. = 18 SQ FT. LAP SIDING PERCENT OF TOTAL= 46%3' - 6"8" 12"24" RETURNS TYP. 4" 12"6" 12"4" 12"6" 12"8" / 12"24" RETURNSTYP.6" 12"6" 12"6" 12"4" 12"8" / 12"VINYL SIDING& CORNERS TYP.ALUMINUM SOFFIT& FASCIA TYP.6" / 12"4" / 12"8" 12"6" / 12"1/4" = 1'-0"A-2011FRONT ELEVATION1/8" = 1'-0"A-2012LEFT ELEVATIONDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:4/26/2024 10:58:22 AMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-201OTT4534.26.24 CB554126410114.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINE1/8" = 1'-0"A-2013RIGHT ELEVATION1/8" = 1'-0"A-2014REAR ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONSA-401 FOUNDATIONA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 ROOF/ SECTIONA-502 DETAILSA-503 WINDOW/ DETAILS
*ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE, NOT INSULATION2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE2'-10"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.24' - 2"25' - 6"49' - 8"22' - 2"2' - 0"26' - 4"49' - 8"15' - 6"34' - 2"27' - 0"7' - 2"3' - 10"11' - 8"10' - 0"19' - 2"7' - 6"14' - 4"29' - 2"21' - 10"51' - 0"0' - 10 1/2"8' - 3" M.O.0' - 10 1/2"1' - 5 1/2"16' - 3" M.O.1' - 5 1/2"21' - 4"8' - 4"14' - 4"15' - 6"7' - 10"19' - 4"2' - 7 1/4"3' - 8 3/4"3' - 8 3/4"14' - 7 1/4"14' - 9 3/4"7' - 8 1/4"4' - 6"2A-5012x4 STUDS @ 16" O.C. ONHALF-HIGH 4" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.3'-6"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"4' - 1 3/4"22' - 2 1/4"7' - 0"44' - 0"51' - 0"42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY3' - 9 1/4"7' - 9 1/2"2' - 9 1/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:4/26/2024 10:58:23 AMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-401OTT4534.26.24 CB554126410114.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINE1/4" = 1'-0"A-4011FOUNDATION PLAN
UNEXCAVATEDUNEXCAVATEDSUMPFURNACEF. D.W. H.BATH11' - 8"3' - 10"7' - 2"27' - 0"CO DET.SMOKEDET.7' - 8"6' - 8"15' - 6"34' - 2"49' - 8"51' - 0"29' - 2"21' - 10"10' - 0"19' - 2"7' - 6"14' - 4"49' - 8"24' - 2"25' - 6"INSULATE BETWEENWALL & SLAB11 7/8" LSL JOISTS@ 16" O.C.23' - 10 1/4"5' - 4 1/2"4' - 2 1/4"5' - 1"5' - 6"SMOKEDET.AIR EX.22' - 2"2' - 0"15' - 6"7' - 10"21' - 4"8' - 4"22' - 2"3' - 6"3' - 6"14' - 10"4' - 10"3' - 8"17' - 10"12' - 0"4' - 0"0' - 4"6' - 0" B.W.P.6' - 0" B.W.P.3' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.2-9 1/2" LVL W/ 2 TRIMMERS2-2x1024" CANT.ABOVE12/4 x 6/8R.O. 2' -6" x 6' -11"2' - 8" B.W.P.2-2x10 51' - 0"2-2x10 6' - 2"19' - 10"9' - 4"2' - 0"1' - 8"6' - 4"2' - 10"42/8 x 6/8R.O. 2' -10" x 6' -11"MECHANICALLAUNDRY3' - 0" B.W.P.12' - 0"5' - 0"17' - 2"FAMILY ROOMBEDROOM #4BEDROOM #511' - 0"5' - 0"11' - 0"12/4 x 6/8R.O. 2' -6" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"42/8 x 6/8R.O. 2' -10" x 6' -11"4' - 0" B.W.P.2-9 1/2" LVL W/ 2 TRIMMERS8' - 10 1/2"9' - 8 1/2"17' - 11"7' - 6"7' - 0"44' - 0"2-9 1/2" LVL W/ 2 TRIMMERS2x4 STUDS @ 16" O.C. ONHALF-HIGH 4" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.WS2x64' VANITY0' - 4"29' - 8"26' - 0"2-2x10 2-2x1042/8 x 6/8R.O. 2' -10" x 6' -11"WALL BUILTTO BOTTOM OF WINDOW1' - 0"4' - 2"2-9 1/2" LSLW/ 2 TRIMMERS2-2x10 EQEQ*ALL DIMENSIONS ARE TO EXTERIOR OF CONCRETE/ SHEATHINGNOT INSULATION20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACINGCRAWL SPACE12" CANT. ABOVE 2-2x10 95040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"1367640 NVGER.O. 7' -6" x 4' -0"H.H. 6' -10"22036 NVH1R.O. 2' -0" x 3' -6"H.H. 6' -10"117636 NVGER.O. 7' -6" x 3' -6"H.H. 6' -10"42/8 x 6/8R.O. 2' -10" x 6' -11"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESSMOKEDET.12/4 x 6/8R.O. 2' -6" x 6' -11"R & SHR & SHCLOSETCLOSETSET FIREPLACE 12" A.F.F. W/ TILE SURROUND AND MANTELTECH TUBE ABOVE 1' - 4 1/2"36" GAS F.P.5' - 0"SINKWASHERDRYER96/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"5' TUB/SHWRSTEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.STEP FOOTING & FOUNDATIONMAXIMUM 3:1 DROP IN GRADEALLOWED. STEP FOOTING &FOUNDATION AS REQUIRED.1/4" = 1'-0"A-4021LOWER FLOOR PLANDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:4/26/2024 10:58:24 AMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-402OTT4534.26.24 CB554126410114.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINEHeader Spans:Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***
29' - 2"21' - 10"51' - 0"10' - 0"19' - 2"7' - 6"14' - 4"51' - 8"2' - 0"27' - 0"7' - 0"11' - 8"4' - 0"FOYERBEDROOM #2HALLDININGKITCHENGARAGESTOOP1' - 0"8' - 0"1' - 0"1' - 7"16' - 0"1' - 7"KNEE WALL W/14" SPINDLES 4' - 7 1/2"3' - 4 1/2"4' - 0"7' - 4"3' - 0"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. CEILING1/2" GYP. BD. ON GARAGE WALLSR-38 MIN. INSULATION IN FLOOR ABOVEGARAGE PLATE HEIGHT TO MATCHFOYER PLATE HEIGHT UNLESS NOTED OTHERWISECO DET.SMOKEDET.2-2x10SEE COLUMN DETAILSHEET A-50224' - 2"27' - 6"2' - 0"25' - 6"22' - 2"2' - 0"0' - 6"7' - 0"0' - 6"3' - 6"5' - 0"21' - 0"2-14" LVLFLOOR LINE ABOVE20" FLOOR TRUSSESPER MFG. SPACINGATTICACCESS2' - 8" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.6' - 0" B.W.P.PFH BRACEDWALL PANEL3' - 0" B.W.P.2-2x10 W/ 2 TRIMMERS2A-50129' - 5 3/4"2' - 6"12' - 0 1/4"GIRDER TRUSS 5x5 PSL5x5 PSL3' - 0" B.W.P.8' - 6"5' - 8"8' - 8"8' - 8"5' - 5 1/4"7' - 0 3/4"14' - 2"17' - 4"12' - 6"7' - 0"44' - 0"22' - 2"3' - 6"3' - 6"14' - 10"21' - 8"8' - 0"32/6 x 6/8R.O. 2' -8" x 6' -11"R & SH51' - 0"17' - 6"1' - 8"5' - 0"11' - 10"2-9 1/2" LSL FLUSH2-9 1/2" LSL FLUSH2-9 1/2" LSL 6' - 8 1/4"20' - 3 3/4"3' - 3"3' - 9"3' - 0" B.W.P.51' - 8"1116' x 8' O.H. GARAGE DOOR6' - 4"1' - 8"2-2x1036' - 0"15' - 8"GIRDER FLOOR TRUSSTRIANGLE OPENING W/ RAILING BETWEEN STAIRS 108' x 8' O.H. GARAGE DOORSMOKEDET.26' - 0"8' - 0"SINK3' - 6"3' - 9"96/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"13' - 0 3/4"3' - 7 3/4"9' - 3 1/2"BEDROOM #3LIVING ROOMDW4' - 0"7' - 0"TYP0' - 4 1/2"85/0 x 6/8R.O. 5' -2" x 6' -11"4' - 6 1/2"BOTTOM OF WINDOW FRAMED 42" A.F.F.2-2x10 CONT.3-2x102-2x1085/0 x 6/8R.O. 5' -2" x 6' -11"R & SH32/6 x 6/8R.O. 2' -8" x 6' -11"R & SH2x6VAULTVAULT LINEVAULTFLAT3:123:12THIS WALL TO BE BALLOON FRAMEDINTO SCISSOR TRUSS ABOVE 2' - 8" B.W.P.3' - 8"4' - 0"5' - 3 1/2"3' - 10"14' - 10 1/2"1' - 0"3' - 8"3' - 8"5' VANITY5' TUB/SHWRFACE FRAME LINEN OVER ENTRY CLOSET18" DEEP36" REFCABINET SURROUND ON REFRIGERATOR 4A-503VAULTFLAT2-2x10 W/ 2 TRIMMERS2-2x102-2x10MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.BATH4-2x611' - 5 1/2"2' - 6"5' - 4 1/2"2' - 8 1/4"7' - 4 3/4"2' - 10"553640 NVPWG/3620 NVA1 TEMP.R.O. 3' -6" x 6' -0"H.H. 6' -10"595040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"95040E NVG1R.O. 5' -0" x 4' -0"H.H. 6' -10"75020 NVPWGR.O. 5' -0" x 2' -0"H.H. 7' -0"43060 NVH2 ER.O. 6' -0" x 6' -0"H.H. 6' -10"32/6 x 6/8R.O. 2' -8" x 6' -11"12/4 x 6/8R.O. 2' -6" x 6' -11"52/8 x 6/8 FIRE RATEDR.O. 2' -10 1/4" x 6' -11"95040E NVG1R.O. 5' -0" x 4' -0"H.H. 7' -6"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTESPFH1' - 7"PFH1' - 7"3' - 0" B.W.P.2' - 8" B.W.P.TRASH ROLL OUT 63/0 x 6/8 W/ 12" D.S. SLTEMPERED GLASS @ LOWER SASHES OVEN /MICRO12/4 x 6/8R.O. 2' -6" x 6' -11"16" SHELVING5' - 0"36" COOKTOP W/ WOOD HOOD ABOVE 2' - 9 1/32"PAN.ELONGATED CONC. PAD4' - 0" B.W.P.B.W.P.4' - 0"1' - 0"1/4" = 1'-0"A-4031MAIN FLOOR PLANDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:4/26/2024 10:58:26 AMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-403OTT4534.26.24 CB554126410114.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINEHeader Spans:Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***Girder Truss4-2x63-11 7/8" LVL
EN SUITEPRIMARY SUITEBOX VAULT11' - 1"11' - 1"CO DET.SMOKEDET.SMOKEDET.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.4' - 0" B.W.P.22/4 x 6/8 PKTR.O. 4' -10" x 6' -11"MFG. ROOF TRUSSES@ 24" O.C.2A-50122' - 2"7' - 6"42/8 x 6/8R.O. 2' -10" x 6' -11"19' - 2 1/4"2' - 11 3/4"2x6TYP.2' - 0"3' - 6"4' - 0"29' - 8"6' - 8"5' - 1"4' - 1"2' - 0"4' - 4"5' - 2"9' - 4"2' - 8"20' - 8"5' - 0"1' - 0"1' - 10"14' - 4"LANDINGVAULT FLAT18' - 7 1/2"3' - 6 1/2"22' - 2"8' - 4"17' - 2"ATTICACCESS22' - 2"3' - 6"3' - 6"14' - 10"5' - 0"R&SHHEAD12/4 x 6/8R.O. 2' -6" x 6' -11"2-2x102-2x10 W/ 2 TRIMMERSTILE SHOWERKNEE WALL W/14" SPINDLES SHAMPOO SHELFSEATDOUBLE FRAMED PLUMBING WALL2-2x102-2x102-2x10VAULTFLATVAULT LINE3:123:126' - 8 3/4"3' - 4"12' - 1 1/4"3' x 5' TUB W/ TILEDECK12/4 x 6/8R.O. 2' -6" x 6' -11"DBL R&SH2' - 4"48" WALL W/ GLASS PANEL5'-6" VANITY1' - 10"4A-5031'-6" LINENCONTROLVAULTFLATMFG. ROOF TRUSSES@ 24" O.C.CLOSET33016 NVA1 TEMP.R.O. 3' -0" x 1' -6"H.H. 6' -10"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"12020 NVA1R.O. 2' -0" x 2' -0"H.H. 6' -10"64030 NVPWGR.O. 4' -0" x 3' -0"H.H. 6' -10"CS-WSP METHOD BRACED WALL PANELS-8d NAILS 6" ON EDGES & 12" IN FIELD,STACK BETWEEN LEVELS WHEN POSSIBLE.USE (3) 16d NAILS NEXT TO EACHSTUD TO SECURE WALL DOWN TO DECKAT BRACED WALL PANELS.EXPOSURE CATEGORY BASSUMED BRACED WALL NOTES78" TILE WALL HEIGHT TYP. 127646 NVGER.O. 7' -6" x 4' -6"H.H. 6' -10"74/0 x 6/8 BYPASSR.O. 4' -2" x 6' -11"COMFORT HEIGHT, ELONGATED DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:4/26/2024 10:58:27 AMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-404OTT4534.26.24 CB554126410114.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINE1/4" = 1'-0"A-4041UPPER FLOOR PLANHeader Spans:Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***
STANDARD ENERGY HEELS @ 4:12 6:12 & 8:12 FASCIA LINES TO MATCH18" OVERHANGS & 12" RAKES TYP.ROOF VENT (10) PER CODE (2) ROOF VENTS THIS AREA (3) ROOF VENTS IN THIS AREA (5) ROOF VENTS IN THIS AREA 4" / 12"8" / 12"6" / 12"6" / 12"6" / 12"8" / 12"4" / 12"6" / 12"6" / 12"6" / 12"6" / 12"6" / 12"8" / 12"8" / 12"MAIN FLOOR6' -7 3/8"MAIN PLATE14' -8 1/2"LOWER FLOOR-3' -2 1/2"T.O. TYP FOOTING-3' -6"T.O. FOUNDATION0' -0"LOWER PLATE4' -10 5/8"FOYER FLOOR1' -2 1/8"GARAGE PLATE9' -3 1/4"UPPER FLOOR11' -0"UPPER PLATE19' -1 1/8"CRAWL SPACEFOYERMAIN PLATE HEIGHT8' - 1 1/8"MFG. ROOF TRUSSES@ 24" O.C.7 RISERS 4' - 4 5/8"9 RISERS 5' - 5 1/4"7 RISERS4' - 4 5/8"11 7/8" LSL JOISTSBATHLANDINGUPPER PLATE HEIGHT8' - 1 1/8"FOYER PLATE HEIGHT8' - 1 1/8"20" FLOOR TRUSSES 20" FLOOR TRUSSES LOWER FLOOR PLATE HEIGHT8' - 1 1/8"LIVING ROOM3" 12"6" 12"4" 12"6" 12"DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:4/26/2024 10:58:28 AMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-501OTT4534.26.24 CB554126410114.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINE1/8" = 1'-0"A-5011ROOF PLAN1/4" = 1'-0"A-5012SECTION3" MIN. ABS OR PVC GASTIGHTPIPE FROM SUBSLAB TOMIN. 12" ABOVE ROOF, MUSTBE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TOSUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY)IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0"AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESSTHAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BEMIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING INADJOINING OR ADJACENTBUILDINGS.SUFFICIENT SPACE MUST BELEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BEMIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALLSOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELSOF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHERBARRIERS IF AIRFLOW HASBEEN ESTABLISHED.LABEL THE VENT PIPE AT LEASTONCE PER FLOOR AND INACCESSIBLE ATTICS WITH"RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE ISREQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM:
ANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATION2" FOAMBOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLVERIFY FLOOR SYSTEMWITH FLOOR PLANS0' - 8"6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATION2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 BLOWINSULATION MIN.FLOOR TRUSSWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHING0' - 10"1x61x6SMOOTHSMARTSIDETYPICAL4x4COREPOST4x4 POSTFRAMING0' - 10"0' - 10"VERIFY FLOOR SYSTEMWITH FLOOR PLANSLOWER FLOOR PLATE HEIGHT8' - 1 1/8"RIM JOISTWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)INSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS4" DRAIN TILE W/WEEP FROM BLOCKTOP COURSE TO BE SOLID BLOCK,BOND BEAM OR GROUTED SOLID 6 MIL. V.B.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEARCHITECTURAL ASPHALT SHINGLES W/ 15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGE3/4" T&GSUBFLOORR-20 SPRAYFOAM INSULATION6 MIL. V.B.1/2" GYP. BD.6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAP5/8" GYP. BD.MAIN FLOOR PLATE HEIGHT8' - 1 1/8"SIDING PER PLANSDRYVIT INSULATION PROTECTION SIDING TO6" BELOW GRADEDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:4/26/2024 10:58:29 AMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-502OTT4534.26.24 CB554126410114.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINE1/2" = 1'-0"A-5023TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5024TYP. WALKOUT SECTION1/2" = 1'-0"A-5026TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5027BEARING WALL SECTION1/2" = 1'-0"A-5022GARAGE CEILING1/2" = 1'-0"A-5021TYP. LOOKOUT SECTION1/2" = 1'-0"A-5025TYP. COLUMN1/2" = 1'-0"A-5028TYP. WALL SECTION
FASTEN TOP PLATE TOHEADER W/ (2) ROWS OF16d SINKER NAILS @3" O.C. TYP.MIN. 3/8" WOODSTRUCTURAL PANELSHEATHINGSECTIONTENSION STRAP PERTABLE R602.10.6.4(ON OPPOSITE SIDEOF SHEATHING)IF NEEDED, PANELSPLICE EDGES SHALLOCCUR OVER AND BENAILED TO COMMONBLOCKING WITHINMIDDLE 24" OF WALLMID-HEIGHT. ONEROW OF 3" O.C.NAILING IS REQUIREDIN EACH PANEL EDGE.TYPICAL PORTALFRAME CONSTRUCTION.MIN. DOUBLE 2x4 POST(KING AND JACK STUD).NUMBER OF JACK STUDSPER TABLES R502.5(1) & (2).MIN. 1000 LB HOLD-DOWNDEVICE (EMBEDDED INTOCONCRETE & NAILEDINTO FRAMING)FRONT ELEVATIONMIN. FOOTING SIZE UNDER OPENING IS12" X 12". A TURNED DOWN SLAB SHALLBE PERMITTED AT DOOR OPENINGS.MIN. (1) 5/8" DIA. ANCHOR BOLDINSTALLED PER R403.1.6 W/2" X 2" X 3/16" PLATE WASHER.MIN. REINFORCING OF FOUNDATION,ONE #4 BAR TOP & BOTTOM OFFOOTING. LAP BARS 15" MINIMUM.MIN. (2) 4200 LB STRAP-TYPE HOLD-DOWNS (EMBEDDED INTO CONCRETEAND NAILED INTO FRAMING)MIN. LENGTH OF PANELPER TABLE R602.10.5MIN. DOUBLE 2x4 FRAMING COVEREDWITH MIN. 3/8" THICK WOOD STRUCTURALPANEL SHEATHING W/ 8d COMMON ORGALVANIZED BOX NAILS AT 3" O.C. INALL FRAMING (STUDS, BLOCKING AND SILLS) TYP.HEADER TO JACK STUD STRAP PERTABLE R602.10.6.4 ON BOTH SIDES OFOPENING OPPOSITE SIDE OF SHEATHINGFASTEN SHEATHING TO HEADER WITH8d COMMON OR GALVANIZED BOXNAILS IN 3" GRID PATTERN AS SHOWNMIN. 3" X 11 1/4" NET HEADER,STEEL HEADER PROHIBITED9' - 11 1/4" MAX. HEIGHTHEIGHTPONYWALL12' - 0" MAX TOTAL WALL HEIGHTEXTENT OF HEADER WITH SINGLE PORTALFRAME (ONE BRACED WALL PANEL)2' - 0" TO 18' - 0" FINISHED WIDTH OFOPENING FOR SINGLE OR DOUBLE PORTALMAIN FLOOR6' -7 3/8"MAIN PLATE14' -8 1/2"LOWER PLATE4' -10 5/8"FOYER FLOOR1' -2 1/8"GARAGE PLATE9' -3 1/4"UPPER FLOOR11' -0"UPPER PLATE19' -1 1/8"BATHFOYERMECHANICALFACE FRAME LINEN OVER ENTRY CLOSET18" DEEP4' - 4 5/8"3' - 8 1/2"ENTRY CLOSET LANDING2' - 11 3/4"20" FLOOR TRUSSES 20" FLOOR TRUSSES DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGNLOWER:4/26/2024 10:58:30 AMRATHINAM & KANDASAMYRESIDENCEL4, B3 - GLACIER CREEK 4TH ADD'N18348 GLACIER WAYLAKEVILLE, MN 55044A-503OTT4534.26.24 CB554126410114.19.24 CB8'-1 1/8"8'-1 1/8"3'-6" POUR8'-1 1/8"2829THE JASMINEWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 VECTOR ENVISION SERIES 2 2020 NVA1 2' - 0" 2' - 0" 6' - 10"2 VECTOR ENVISION SERIES 1 2036 NVH1 2' - 0" 3' - 6" 6' - 10"3 VECTOR ENVISION SERIES 1 3016 NVA1 TEMP. 3' - 0" 1' - 6" 6' - 10"4 VECTOR ENVISION SERIES 1 3060 NVH2 E 6' - 0" 6' - 0" 6' - 10"5 VECTOR ENVISION SERIES 3 3640 NVPWG/3620 NVA1 TEMP. 3' - 6" 6' - 0" 6' - 10"6 VECTOR ENVISION SERIES 1 4030 NVPWG 4' - 0" 3' - 0" 6' - 10"7 VECTOR ENVISION SERIES 1 5020 NVPWG 5' - 0" 2' - 0" 7' - 0"9 VECTOR ENVISION SERIES 4 5040E NVG1 5' - 0" 4' - 0" VARIES11 VECTOR ENVISION SERIES 1 7636 NVGE 7' - 6" 3' - 6" 6' - 10"136 VECTOR ENVISION SERIES 1 7640 NVGE 7' - 6" 4' - 0" 6' - 10"12 VECTOR ENVISION SERIES 1 7646 NVGE 7' - 6" 4' - 6" 6' - 10"3/8" = 1'-0"A-5033METHOD PFH - PORTAL FRAME WITH HOLD-DOWNS1/4" = 1'-0"A-5034LINEN SECTIONDOOR SCHEDULETYPE MARK DOOR SIZE ROUGH WIDTH ROUGH WIDTH COUNT COMMENTS1 2/4 x 6/8 2' - 6" 6' - 11" 72 2/4 x 6/8 PKT 4' - 10" 6' - 11" 13 2/6 x 6/8 2' - 8" 6' - 11" 34 2/8 x 6/8 2' - 10" 6' - 11" 65 2/8 x 6/8 FIRE RATED 2' - 10 1/4" 6' - 11" 16 3/0 x 6/8 W/ 12" D.S. SL 17 4/0 x 6/8 BYPASS 4' - 2" 6' - 11" 18 5/0 x 6/8 5' - 2" 6' - 11" 29 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 210 8' x 8' O.H. GARAGE DOOR 111 16' x 8' O.H. GARAGE DOOR 1ROOM FINISH SCHEDULEFLOOR ROOM NAME FLOOR FINISH AREA PLATE HEIGHT COMMENTSLOWER FLOOR CRAWL SPACE 120 SF 3' - 2 1/2"LOWER FLOOR BATH VINYL 52 SF 8' - 1 1/8" .LOWER FLOOR MECHANICAL 71 SF 8' - 1 1/8"LOWER FLOOR LAUNDRY VINYL 66 SF 8' - 1 1/8" .LOWER FLOOR FAMILY ROOM CARPET 433 SF 8' - 1 1/8" .LOWER FLOOR BEDROOM #4 CARPET 141 SF 8' - 1 1/8" .LOWER FLOOR BEDROOM #5 CARPET 134 SF 8' - 1 1/8" .LOWER FLOOR CLOSET CARPET 23 SF 8' - 1 1/8"LOWER FLOOR CLOSET CARPET 20 SF 8' - 1 1/8"FOYER FLOOR FOYER WOOD 89 SF 8' - 1 1/8" .FOYER FLOOR GARAGE 633 SF 9' - 3 1/4"FOYER FLOOR STOOP CONCRETE 30 SF 8' - 1 1/8" .FOYER FLOOR CONC. PAD 100 SF 8' - 1 1/8"MAIN FLOOR BEDROOM #2 CARPET 169 SF 8' - 1 1/8" .MAIN FLOOR HALL WOOD 59 SF 8' - 1 1/8" .MAIN FLOOR DINING WOOD 130 SF 8' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 184 SF 8' - 1 1/8" .MAIN FLOOR BATH VINYL 57 SF 8' - 1 1/8"MAIN FLOOR BEDROOM #3 CARPET 159 SF 8' - 1 1/8" .MAIN FLOOR LIVING ROOM WOOD 244 SF 8' - 1 1/8" .MAIN FLOOR PAN. 17 SF 8' - 1 1/8"UPPER FLOOR EN SUITE L.V.T 120 SF 8' - 1 1/8" .UPPER FLOOR PRIMARY SUITE CARPET 213 SF 8' - 1 1/8" BOX VAULTUPPER FLOOR CLOSET CARPET 69 SF 8' - 1 1/8" .UPPER FLOOR LANDING CARPET 87 SF 8' - 1 1/8"
FLUSH HEADERBY OTHERSFLUSH HEADERBY OTHERSFLUSH HEADERBY OTHERSSEE DETAIL 1SEE DETAIL 1SEE DETAIL 1DETAIL 12X10 HEADERCARRYINGTRUSSCARRIEDTRUSS2X6 TOP CHORDRIBBON BY OTHERS2X10 TOP CHORD RIBBON BY OTHERS20" DEEP TRUSSES24" O.C. BASE SPACING.DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING. TRUSSES HAVE BEEN HELD IN1/2" AT EXTERIOR WALLS FOR SHEATHING.THE PAINTED END DENOTES THE LEFT ENDOF THE FLOOR TRUSS. THIS END OF THEFLOOR TRUSS IS TO BE PLACED WHERE YOUSEE THE TRIANGLE AND THE PAINTED ENDNOTE ON THE PLACEMENT PLAN. THEPAINTED END ALSO CORRESPONDS TO THELEFT SIDE OF THE SEALED TRUSS DRAWING.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBINGLOCATIONS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLJOSH @ 651-287-1944OREMAIL: JRUDESILL@VILLAUME.COMF1F2F2F2F2F2F2F2F4F3F8F9F10F11F13F13F13F14F12F7F17F17F18F19F20F21F5F6F12F1614-02-0017-04-0012-06-0044-00-008-00-0026-00-002-00-0036-00-003-00-00 7-04-00 4-00-00 8-00-0021-08-002-00-0027-00-001-00-006-00-001-10-041-08-001-08-001-08-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-0017-06-001-08-003-10-0419-04-002-10-003-06-003-06-001-11-082-00-00Customer: Lyman Lumber - ChanhassenJob Number: 327564-BHome Owner: TOPAZ / JASMINE / RATHINAM RESJob Name: FloorSite Address: 18348 GLACIER WAY Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Josh Rudesill2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 6/19/2024Version: 8.7.3.303
POST UP TO BOTTOMOF "M3" GIRDER TRUSSPOST UP TO BOTTOMOF "M3" GIRDER TRUSSFLUSH HEADERBY OTHERSFLUSH HEADERBY OTHERSDROPPEDHEADER BYOTHERS2X4 LEDGERBY OTHERS2X4 LEDGERBY OTHERSPLATE HEIGHT BY HATCHING ABOVEMAIN FLOORNON HATCHED: 8-01-02BLUE HATCHED: 2-07-14UPPER WALLS ABOVE GARAGEFLOOR TRUSSES ARE NON-HATCHED20" DEEP TRUSSES24" O.C. BASE SPACING.DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING. TRUSSES HAVE BEEN HELD IN1/2" AT EXTERIOR WALLS FOR SHEATHING.THE PAINTED END DENOTES THE LEFT ENDOF THE FLOOR TRUSS. THIS END OF THEFLOOR TRUSS IS TO BE PLACED WHERE YOUSEE THE TRIANGLE AND THE PAINTED ENDNOTE ON THE PLACEMENT PLAN. THEPAINTED END ALSO CORRESPONDS TO THELEFT SIDE OF THE SEALED TRUSS DRAWING.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBINGLOCATIONS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLJOSH @ 651-287-1944OREMAIL: JRUDESILL@VILLAUME.COMu=0d=14892u=0d=14907u=117d=2553u=117d=25535050365118365118 365118FF1FF2FF2FF2FF2FF2FF2FF2FF2FF3FF5FF6FF7FF7FF4FF8M3HHUS48HHUS48HHUS48HHUS48HHUS48HHUS48HHUS48HHUS48HHUS48HHUS48HHUS48HHUS4812-06-0017-04-0014-02-00 7-00-0051-00-002-00-0025-06-0022-02-002-00-0051-08-002-00-0027-00-001-00-006-00-003-06-006-0015-08-002-00-007-06-00 19-02-00 10-00-001-02-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-06-001-06-001-06-001-00-002-00-002-00-002-00-001-04-008-04-0017-02-003-00-00 7-04-00 4-00-007-00-083-00-00Customer: Lyman Lumber - ChanhassenJob Number: 327564-BHome Owner: TOPAZ / JASMINE / RATHINAM RESJob Name: FloorSite Address: 18348 GLACIER WAY Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Josh Rudesill2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 6/19/2024Version: 8.7.3.303
POST UP TO BOTTOMOF "M3" GIRDER TRUSSPOST UP TO BOTTOMOF "M3" GIRDER TRUSSDROPPEDHEADER BYOTHERS2X4 LEDGERBY OTHERS2X4 LEDGERBY OTHERSPLATE HEIGHT BY HATCHING ABOVEMAIN FLOORNON HATCHED: 8-01-02BLUE HATCHED: 2-07-14UPPER WALLS ABOVE GARAGEFLOOR TRUSSES ARE NON-HATCHEDDIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING.THE TRUSS ID DOES NOT DENOTE THE LEFTEND OF THE ROOF TRUSS ON THEPLACEMENT PLAN. USE THE LEFT END OFTHE SEALED TRUSS DRAWING AND THETRIANGLE ON THE PLACEMENT PLAN TOLOCATE THE PROPER END OF EACH ROOFTRUSS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLJOSH @ 651-287-1944OREMAIL: JRUDESILL@VILLAUME.COMu=0d=14892u=0d=14907u=117d=2553u=117d=2553LO1M2M1M1M1K1K1K1K1K1K1K1K1K1K1K1M3E5E3E2E1E1E1E4E1G1G2D4D4D4D5D3D1D1D1D2C3C6C5C5C1C1C2H2H1H1H1H1C4THA29THA29THA2912-06-0017-04-0014-02-00 7-00-0051-00-002-00-0025-06-0022-02-002-00-0051-08-002-00-0027-00-001-00-006-00-003-06-006-0015-08-002-00-007-06-00 19-02-00 10-00-001-07-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-07-001-06-001-06-002-00-001-06-002-00-002-00-002-00-002-01-041-10-122-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-06-128-04-0017-02-001-04-001-04-002-00-002-00-002-00-002-00-001-11-041-10-003-00-00 7-04-00 4-00-007-00-083-00-00LO2LO2A3A2A2A2A2A2A3A1A3A4A4V1V2V3MUS28MUS282-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-006-08-0014-04-00Customer: Lyman Lumber - ChanhassenJob Number: 327564-BHome Owner: TOPAZ / JASMINE / RATHINAM RESJob Name: FloorSite Address: 18348 GLACIER WAY Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Josh Rudesill2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 6/19/2024Version: 8.7.3.303
Date Certificate Posted
X Passive (No Fan)
Active (With fan and monometer
or other system monitoring
device)
Location (or future location) of Fan:
Other Please Describe Here
R-15 X
R-20 X
R-20 X
R-20 X
R-49 X
R-49 X
R-30 X X
R-30 X
X Not applicable, all ducts located in conditioned space
X Not required per mech. code
Passive
Powered
Interlocked with exhaust device.
Describe:
Input in
BTUS:
70,000 Capacity
in Gallons:
Other, describe:
AFUE or
HSPF%
93
Cfm's
" round duct OR 7" flex
" metal duct
Not required per mech. code
X Passive
Low: Other, describe:
X Low:
Location of fan(s), describe: Cfm's
X " round duct OR 7" flex
" metal duct
City Mailing Address of the Dwelling or Dwelling Unit
Combustion Air Select a Type
Location of duct or system:
2.5
Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.7/3/2024
New Construction Energy Code Compliance Certificate
Name of Residential Contractor
One Ten Ten Homes, LLC
MN License Number
Lakeville18348 Glacier Way
BC730925
Mechanical room
Heat Recover Ventilator (HRV) Capacity in cfms:
Energy Recover Ventilator (ERV) Capacity in cfms:
65012
Heating Gain Cooling Load
80
Fuel Type
Solar Heat Gain Coefficient (SHGC):
Windows & Doors
Ceiling, vaulted
Bay Windows or cantilevered areas
Floors over unconditioned area
Rim Joist (2nd Floor+)
0.27
Appliances
THERMAL ENVELOPE
Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade
RADON CONTROL SYSTEM
Non or Not Applicable Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply
Mineral Fiberboard Insulation Location
Foam, Closed Cell0.32
Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall
R-value
Average U-Factor (excludes skylights and one door ) U:
Duct system air tightness: Building envelope air tightness:
Rim Joist (1st Floor)
GPVL5000L 14ACX030P Model
Heating System
Natural Gas
Lennox
Location of duct or system:
Heating or Cooling Ducts Outside Conditioned Spaces
Electric
Make-up Air Select a Type
AO Smith
Domestic Water
Heater
MECHANICAL SYSTEMS
Rating or Size
Efficiency
14
160
Select Type
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
29235Residential Load Calculation
SEER
/EER
Total ventilation (intermittent + continuous) rate in cfms:
Balanced Ventilation capacity in cfms:
High:
High:
MECHANICAL VENTILATION SYSTEM
Capacity continuous ventilation rate in cfms:
ML19307016C
Heating Loss
Manufacturer Lennox
Natural Gas
Output
in Tons:
2.550
Builders Associaton of Minnesota version 101014
NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION
This form must be completed and submitted with all new residential permit applications.
New residential building permits WILL NOT be issued without this completed form.
Project Site Address: _____________________________________________________________________
Company Name: _________________________________________________________________________
Primary Contact: _________________________________________________________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Description of Land Disturbing Activity: _____________________________________________________
NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___
If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an
erosion and sediment control plan MUST be submitted with the residential building permit application.
Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control
inspections and corrective actions:
Name of Person: ________________________________Company: _______________________________
Phone # (24 hr Contact): ______________________ Email: ______________________________________
Entity that Provided Training: ________________________ Certification Expiration Date: ____________
NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots.
No land disturbing activity may begin until a residential building permit has been issued.
I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National
Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER;
withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater
Permit (MN R 100001) or erosion and sediment control plan.
Signature: ________________________________________________ Date:_________________________
Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500
* If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to
erosion@lakevillemn.gov
“The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA)
“The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA)
7/3/24 X
PM