HomeMy WebLinkAboutLA226004-APPROVED-20980 Jury Ct Solar Permit PlanSHEET INDEX PAGE #DESCRIPTION PV - 01 TITLE SHEET PV - 02 SITE PLAN / STRING DETAILS PV - 03 ELECTRICAL LINE DIAGRAM PV - 04 RACKING DETAILS PV - 05 ELECTRICAL LABELS PV - 06, PV - 06.1 SURVEY ELECTRICAL PHOTOS PV - 07 MAP PLACARD CONTRACTORS LICENSE # & TYPE MINNESOTA FALSE MINNESOTA FALSE APPLICABLE CODES 2020 NATIONAL ELECTRIC CODE (NEC) 2021 INTERNATIONAL RESIDENTIAL CODE (IRC) 2021 INTERNATIONAL BUILDING CODE (IBC) NABCEP CERTIFICATION MICHAEL GARRISON PV 011818-019231 AERIAL VICINITY SCALING NEARMAP 410.1554541 GOOGLE 223.0242061 EAGLEVIEW 588'-0" MODULE(S) MODULE TYPE NUMBER OF MODS MODULE SIZE: WATTS SYSTEM SIZE: WATTS REC 36 410 14760 WATTS INVERTER(S) MANUFACTURER MODEL NUMBER OF INVERTERS SYSTEM OUTPUT ENPHASE ENERGY IQ8X 36 56.93 AMPS JOB DETAILS ROOF MATERIAL STANDARD ASPHALT SHINGLE ROOF SQ FT OF ARRAY ARRAY AZIMUTH(S)52°,232°756.4 RACKING TYPE UL LISTED IRONRIDGE RACKING SYSTEM ATTACHMENT SPACING MAXIMUM ATTACHMENT SPACING 48'' INSTALLATION SURFACE / PANEL ANGLE 26.57° / 26.57° GENERAL NOTES 1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE LATEST STATE CODE OF REGULATIONS, NATIONAL ELECTRICAL CODE EDITION AND ALL APPLICABLE LOCAL CODES AND REGULATIONS. 2. ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER SPACE AND LUGS IN COMPLIANCE TO UL REQUIREMENTS TO ACCOMMODATE CONDUCTORS SHOWN. 3. WHERE WIRE SIZES ARE INDICATED ON PLANS, FOR INDIVIDUAL CIRCUITS, THE WIRE SIZE INDICATED SHALL APPLY TO THE COMPLETE CIRCUIT, UNLESS OTHERWISE NOTED. 4. CONTRACTOR SHALL EXTEND WIRING FROM ALL JUNCTION BOXES, SWITCHES, ETC. AND MAKE FINAL CONNECTION AS REQUIRED TO ALL BUILDING EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. 5. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED. FOLLOW DRAWING IN LAYING OUT WORK AND CHECK DRAWINGS OR OTHER TRADES RELATING TO WORK TO VERIFY SPACE IN WHICH WORK WILL BE INSTALLED. MAINTAIN HEADROOM AND MINIMUM CODE REQUIRED WORKING CLEARANCES AT ALL TIMES. 6. ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE THAT ARE EXPOSED TO OUTSIDE ENVIRONMENT SHALL BE WEATHERPROOF TYPE, NEMA 3R. 7. DISCONNECT SWITCHES SHALL BE MOUNTED ON INDIVIDUAL SUPPORTS, OR OTHERWISE DIRECTLY ON EQUIPMENT, PROVIDED. 8. NO MODIFICATION TO EQUIPMENT IS NECESSARY. ALL ELECTRIC MATERIAL SHALL BE LISTED BY "UL" FOR THE TYPE OF APPLICATION AND "UL" LABEL SHALL APPEAR ON ALL ELECTRICAL EQUIPMENT. 9. WIRING METHOD SHALL BE EMT ABOVE GROUND AND MOUNTED IN CONCEALED SPACES (UNLESS APPROVED OTHERWISE) AND SCHEDULE - 40 PVC FOR BELOW GROUND INSTALLATION UNLESS NOTED OTHERWISE. 10. FOR WOOD CONSTRUCTION, THE SOLAR PV SYSTEM SUPPORTS SHALL BE ANCHORED TO SOLID ROOF RAFTERS OR TO SOLID BLOCKING WITH A MINIMUM OF ONE 5/16-INCH (8 MM) DIAMETER LAG SCREW EMBEDDED A MINIMUM OF 2-1/2 INCHES (64 MM). 1 SHEET # SCALE:819 N LAGOON DRIVEFARMINGTON, UT 84025PHONE: (801) 317-8444DATE:7/19/2024DESIGNER:D HANSENSYSTEM SIZE:14760 WATTSAHJ:Lakeville City, MNRYAN SEYS20980 JURY COURTLAKEVILLE, MINNESOTA 55044SOLARREVISIONS:PROJECT #5-23-2024: R. MIZE13488016-21-202427-19-2024: R. MIZE3N/A4N/A5N/A6PV-01 N.T.S Concept Approval ONLYSubject to Field Inspection Inspector Date 2015 MN Bldg Code 07/31/2024jnuetzman SOURCE CIRCUITS # OF MICROINVERTERS 1 10 2 10 3 10 4 6 FIRE CODE CONCRETE NEMA-4 ROOFTOP JUNCTION BOX ENPHASE COMBINERE AC DISCONNECTAC CHARGE CONTROLLERCC FENCE METER-MAIN PANELM POINT OF INTERCONNECTION NOTE: 1.THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY! 2.ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNEL, WITH PROPER PERSONAL PROTECTIVE EQUIPMENT. 3.AC DISCONNECT SHOULD BE LOCATED TOGETHER IN A READILY ACCESSIBLE LOCATION WITHIN 10' OF THE MAIN SERVICE METER. 4.24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED FOR XCEL ENERGY EQUIPMENT. 5.UTILITY AC DISCONNECT SHOULD BE LOCATED WITHIN 10 FEET OF THE MAIN SERVICE METER. 6.SOLAR PV SHALL BE USED AS A SECONDARY INTERCONNECTION. 7.MAXIMUM 1' SPACING BETWEEN COMPONENTS. 8.NEAREST CROSS ROAD - ELK LAKE RD APPROX. 721' SW NO POSITION, DISTANCE AND CLEARENCE CONCERNS OF OVERHEAD ELECTRIC SERVICE LINES AND/OR OTHER UTILITIES IN RELATION TO THE PV PANELS *MICROINVERTERS ARE MODULE INTEGRATED TOTAL PANELS:36 TOTAL INVERTERS:36 DC SYSTEM SIZE (kW):14.76 kW AC SYSTEM SIZE (kW):13.662 kW ROOF COVERAGE: TOTAL ROOF AREA (SQFT):3504 TOTAL ARRAY AREA (SQFT):691.2 % OF ROOF COVERAGE:19.73% SYMBOL:MEANING: JURY COURT PV ARRAY #1 AZIMUTH: 232 TILT: 26.57° # OF MODULE: 32 PV ARRAY #2 AZIMUTH: 52 TILT: 26.57° # OF MODULE: 4 AC CCPAC E M SPCL PRODUCTION METERP CRITICAL LOAD PANELCL UTILITY ACCOUNT #: 51-0013855882-3 UTILITY APPLICATION #: 05776168 1 1 1 2 3 SHEET # SCALE:819 N LAGOON DRIVEFARMINGTON, UT 84025PHONE: (801) 317-8444DATE:7/19/2024DESIGNER:D HANSENSYSTEM SIZE:14760 WATTSAHJ:Lakeville City, MNRYAN SEYS20980 JURY COURTLAKEVILLE, MINNESOTA 55044SOLARREVISIONS:PROJECT #5-23-2024: R. MIZE13488016-21-202427-19-2024: R. MIZE3N/A4N/A5N/A6MODULE(S) MODULE TYPE NUMBER OF MODS MODULE SIZE: WATTS SYSTEM SIZE: WATTS REC 36 410 14760 WATTS INVERTER(S) MANUFACTURER MODEL NUMBER OF INVERTERS SYSTEM OUTPUT ENPHASE ENERGY IQ8X 36 56.93 AMPS JOB DETAILS ROOF MATERIAL STANDARD ASPHALT SHINGLE ROOF SQ FT OF ARRAY ARRAY AZIMUTH(S)52°,232°756.4 RACKING TYPE UL LISTED IRONRIDGE RACKING SYSTEM ATTACHMENT SPACING MAXIMUM ATTACHMENT SPACING 48'' INSTALLATION SURFACE / PANEL ANGLE 26.57° / 26.57° PV-02 1 16"= 1'Jul 19 2024 CONDUIT AND CONDUCTOR SCHEDULE TAG#DESCRIPTION 1 (3) MICROINVERTER TRUNK LINE (1) #6 BARE COPPER EG 2 (IN ATTIC) (3) #10-2 ROMEX CABLE, (1) #10 THWN-2 CU EG 3 (1) MIN 3/4'' EMT, (6) #10 THWN-2 CU, (1) #10 THWN-2 CU EG 4 (1) MIN 1'' EMT, (3) #6 THWN-2 CU, (1) #6THWN-2 CU EG 5 (1) MIN 1' EMT, (3) #3 THWN-2 CU, (1) #6THWN-2 CU EG INVERTER SPECIFICATIONS MANUFACTURER ENPHASE ENERGY MODEL IQ8X-80-M-US (GRID TIED) MAX DC INPUT VOLTAGE 79.5 VDC MAX OUTPUT POWER 379.5 W MAX DC INPUT POWER 460 W NOMINAL AC OUTPUT VOLTAGE 240 VAC (SINGLE PHASE) NOMINAL AC OUTPUT CURRENT 1.58 A MAX FUSE (OCPD)20 A TOTAL PANELS:36 TOTAL INVERTERS:36 DC SYSTEM SIZE (kW):14.76 kW AC SYSTEM SIZE (kW):13.662 kW NOTES: 1.THIS SYSTEM MEETS THE REQUIREMENTS OF NEC 690.41 2.THE DC CONDUCTORS ARE NOT BONDED TO GROUND AND THE INVERTERS DO NOT REQUIRE A GEC. 3.NEC 690.43(C) STRUCTURE AS EQUIPMENT GROUNDING CONDUCTOR ALLOWS FOR EQUIPMENT TO BE USED AS THE EGC IN A PHOTOVOLTAIC SYSTEM. 4.THE DEVICES LISTED AND IDENTIFIED FOR GROUNDING THE EQUIPMENT MAY BE STAND-ALONE GROUNDING COMPONENTS OR UL-2703 LISTED MOUNTING HARDWARE. MODULES ARE BONDED TO THE RACKING WITH LISTED AND APPROVED GROUNDING COMPONENTS. 5.EQUIPMENT OPERATING 150 VOLTS OR GREATER SHALL ONLY BE SERVICED OR REPLACED BY QUALIFIED PERSONNEL. FIELD PROTECTION MAY BE IN THE FORM OF CONDUIT, CLOSED CABINET OR AN ENCLOSURE WHICH REQUIRE USE OF TOOLS TO OPEN. 6.SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ART. 690 OF THE 2017 NEC. 7.LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. 8.ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 9.WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE PER NEC 110.2, 110.3(A), 110.3(B) & 300.4 10.EQUIPMENT TERMINATIONS SHALL BE RATED MINIMUM 75 C. 2017 NEC ARTICLE 110.14(C)(1). 11.ROOF TOP CONDUITS SHALL BE MINIMUM 7/8 INCH ABOVE THE ROOFTOP. 2017 NEC ARTICLE 310.15(B) 12.ALL PV ROOFTOP CONDUCTORS NOT UNDER THE ARRAY SHALL BE PROTECTED BY A RACEWAY WITH A LISTED JUNCTION BOX AT BOTH ENDS. 2017 NEC ARTICLE 690.31(A) ALL AC PV EQUIPMENT IS 240V (SINGLE PHASE) MODULE SPECIFICATIONS MANUFACTURER REC MODEL REC410AA PURE MAX POWER-POINT CURRENT (IMP)-AMPS 9.72 MAX POWER-POINT VOLTAGE (VMP)-VOLTS 42.2 OPEN CIRCUIT VOLTAGE (VOC)-VOLTS 49.4 SHORT CIRCUIT CURRENT (ISC)-AMPS 10.42 MAX SERIES FUSE (OCPD)-AMPS 30 MAX POWER (PMAX)410 WATTS PHOTOVOLTAIC AC OUTPUT AC OUTPUT CURRENT 56.93 AMPS NOMINAL AC VOLTAGE 240 MAX OCPD RATING 80AAC 100A/2P BI-DIRECTIONAL SINGLE PHASE UTILITY METER UTILITY GRID 120/240V EXISTING 150A SERVICE ENTRANCE 150A/2P PLACARD REQ. YELLOW W/ BLK LETTERING "SERVICE AC DISCONNECT" LOCKABLE W/ VISIBLE OPEN AND READILY ACCESSIBLE UL 1741 CERTIFIED PLACARD REQ. YELLOW W/ BLK LETTERING "PHOTOVOLTAIC SYSTEM CONNECTED" -PV PRODUCTION METER SOCKET BEING IN COMPLIANCE WITH SECTION 4.11 OF THE XCEL ENERGY STANDARD AS OF JULY 31, 2022 REVISIONS. -PV PRODUCTION METER TO HAVE A STAMPED BRASS, ALUMINUM, OR STAINLESS STEEL TAG INDICATING THE ADDRESS INCLUDING UNIT, AND “PV UTILITY PROD” IN ACCORDANCE WITH THE REQUIREMENTS FOR METER IDENTIFICATION IN SECTION 4.14.4 OF THE XCEL ENERGY STANDARD. 240V, 1-PHASE, 3-WIRE, WITHIN 10' OF BILLING METER. *ALL NEW AC PV EQUIPMENT IS 120/240V (SINGLE AND/OR 1 PHASE) *ALL EXISTING UTILITY EQUIPMENT IS 120/240V (SINGLE AND/OR 1 PHASE) PLACARD REQ. YELLOW W/ BLK LETTERING "PV UTILITY AC DISCONNECT" LOCKABLE W/ VISIBLE OPEN AND READILY ACCESSIBLE RPA:REFERENCE POINT OF APPLICABILITY 1010 10 20A-2P 20A-2P 20A-2P WITHIN 10' OF UTILITY METER 100A 120/240V DISCONNECT NON-FUSED 44 NEMA-4 J-BOX NEMA 3R JUNCTION BOX 3 2 1 ROOF MOUNT BREAKERS IN ENPHASE COMBINER ARE HOLD-DOWN FOR EACH STRING 125A 120/240V ENPHASE AC COMBINER (80A TOTAL CIRCUIT RATING) CONDUCTOR CALCULATIONS TAG# CALCULATED AMPERAGE (AT MAXIMUM CIRCUIT POTENTIAL) CONDUCTOR USED ALLOWABLE AMPACITIES 75° (NEC 310.15(B)(16)) 1 15.73*1.25 = 19.66 AMPS MICROINVERTER TRUNK LINE 35 AMPS2 (TEMP) (4 CCC) 15.73*1.25 = 19.66 AMPS #10-2 ROMEX CABLE (THHN)35 AMPS 3 (4 CCC)15.73*1.25 = 19.66 AMPS #10 THWN-2 CU 35 AMPS 4 47.25*1.25 = 59.09625 AMPS #6 THWN-2 CU 65 AMPS 5 100 AMPS #3 THWN-2 CU 100 AMPS WITHIN 10' OF UTILITY METER 100A 120/240V DISCONNECT NON-FUSED 5 CHARGE CONTROLLER TO BE SET TO LIMIT BACKFEED TO THE MSP AT 30A 80A/2P 100A/2P ENPHASE CHARGE CONTROLLER (A.T.S) CRITICAL LOADS SUB-PANEL 5 HEAT DETECTOR TO BE INSTALLED IN CRITICAL LOADS PANEL 5 PROD. METER LINE SIDE LOAD SIDE 4 INTERCONNECTION PCC MADE IN EXISTING EXTERIOR 240VAC, 150AAC SINGLE PHASE / 3-WIRE METER MAIN PANEL WITH LOAD SIDE TAP ON 150AAC. TAP WILL LAND ON DEDICATED PV BREAKER SPOT IN NEW ENPHASE CHARGE CONTROLLER. THIS CONNECTION SHALL BE MADE IN CONFORMANCE WITH 2020 NEC 705.12(B)(2). 100A/2P UTILITY ACCOUNT #: 51-0013855882-3 UTILITY APPLICATION #: 05776168 20A-2P 6 TOTAL PANELS:36 TOTAL INVERTERS:36 DC SYSTEM SIZE (kW):14.76 kW AC SYSTEM SIZE (kW):13.662 kW 1 1 1 2 2 SHEET # SCALE:819 N LAGOON DRIVEFARMINGTON, UT 84025PHONE: (801) 317-8444DATE:7/19/2024DESIGNER:D HANSENSYSTEM SIZE:14760 WATTSAHJ:Lakeville City, MNRYAN SEYS20980 JURY COURTLAKEVILLE, MINNESOTA 55044SOLARREVISIONS:PROJECT #5-23-2024: R. MIZE13488016-21-202427-19-2024: R. MIZE3N/A4N/A5N/A6PV-03 N.T.S MEETS OR EXCEEDS IBC IRC CONSTRUCTION STANDARDS CASE 1 Load Calculations 2X4 Construction 24'' on Center Trusses REC 410 Watt PV Panel: < 50 LBS/Panel IRONRIDGE CONNECTION HARDWARE: .735 PLF * 6.66 FT/PANEL = 4.8951 LBS/PANEL SYSTEM INCLUDES 36 PANELS AND IRONRIDGE MOUNTING HARDWARE: 36 X 54.9 = 1976.4 LBS A = L x W (PANEL): 19.2 SQ FT ARRAY: 19.2 SQ FT x 36 = 691.2 SQ FT SNOW LOAD: 691.2 SQ FT x 30 PSF = 20736 LBS PULL OUT STRENGTH: 72 5/16 LAG BOLTS 72 x 3'' EMBED x 205 LBS = 44280 LBS MINIMUM ATTACHMENT DEPTH 2-1/2'' TOTAL WEIGHT = PANELS + HARDWARE = 1976.4 LBS 1976.4 LBS / 691.2 SQ FT = 3.02 PSF ROOF LOAD BEARING: 1976.4 LBS / 72 STANDOFFS = 27.45 LBS 3.83 .38 3.35 1.63 3.00 .40 .34 .26 1.56 1 RD STRUCTURAL SCREW PN RD-1430-01-M1 SOLD SEPARATELY SHOWN FOR REFERENCE Release Linershown for reference PART NUMBER DESCRIPTION QM-HUG-01-M1 Halo UltraGrip - Mill QM-HUG-01-B1 Halo UltraGrip - Black QuickMount® Halo UltraGrip TYP. IRONRIDGE UFO + END SLEEVE TYP. IRONRIDGE UFO MODULE CLAMP TYP. QUICKBOLTS 5 1/4 " MICRO FLASHING TYP. IRONRIDGE XR10 RAIL TYP. IRONRIDGE L-FOOT TYP. IRONRIDGE UFO + END SLEEVE TYP. IRONRIDGE UFO MODULE CLAMP TYP. QUICKBOLTS 5 1/4 " MICRO FLASHING TYP. IRONRIDGE XR10 RAIL TYP. IRONRIDGE L-FOOT LANDSCAPE INSTALLATION PORTRAIT INSTALLATION MAXIMUM ATTACHMENT SPACING 48''SHEET # SCALE:819 N LAGOON DRIVEFARMINGTON, UT 84025PHONE: (801) 317-8444DATE:7/19/2024DESIGNER:D HANSENSYSTEM SIZE:14760 WATTSAHJ:Lakeville City, MNRYAN SEYS20980 JURY COURTLAKEVILLE, MINNESOTA 55044SOLARREVISIONS:PROJECT #5-23-2024: R. MIZE13488016-21-202427-19-2024: R. MIZE3N/A4N/A5N/A6PV-04 N.T.S Jul 19 2024 ALL SIGNAGE MUST BE PERMANENTLY ATTACHED AND BE WEATHER RESISTANT/SUNLIGHT RESISTANT AND CANNOT BE HAND-WRITTEN CONDUITS, ENCLOSURES, OR MC Cable THAT CONTAIN DC CIRCUITS EVERY 10' LOCATED AT SERVICE PANEL BOARD NEC 690.54 LOCATED ON STRING INVERTER (IF USED) NEC 690.53 LOCATED AT MAIN PV DISCONNECT NEC 690.13(B) LOCATED AT RAPID SHUTDOWN DISCONNECT NEC 690.56(C)(3) LOCATED AT SERVICE PANEL NEC 705.10 LOCATED AT PV BREAKER IN PANEL BOARD NEC 705.12(B)(2)(3)(b) LOCATED AT SERVICE PANEL NEC 690.56(C)(1) LOCATED ON MULTI BRANCH PV SUB-PANEL 480 0 45 240 56.93 AMPS 480 0 45 240 56.93 AMPS SHEET # SCALE:819 N LAGOON DRIVEFARMINGTON, UT 84025PHONE: (801) 317-8444DATE:7/19/2024DESIGNER:D HANSENSYSTEM SIZE:14760 WATTSAHJ:Lakeville City, MNRYAN SEYS20980 JURY COURTLAKEVILLE, MINNESOTA 55044SOLARREVISIONS:PROJECT #5-23-2024: R. MIZE13488016-21-202427-19-2024: R. MIZE3N/A4N/A5N/A6PV-05 N.T.S SHEET # SCALE:819 N LAGOON DRIVEFARMINGTON, UT 84025PHONE: (801) 317-8444DATE:7/19/2024DESIGNER:D HANSENSYSTEM SIZE:14760 WATTSAHJ:Lakeville City, MNRYAN SEYS20980 JURY COURTLAKEVILLE, MINNESOTA 55044SOLARREVISIONS:PROJECT #5-23-2024: R. MIZE13488016-21-202427-19-2024: R. MIZE3N/A4N/A5N/A6PV-06 N.T.S TO BE PLACED ON METER MAIN PANEL.705.10 & 690.56(B)ENPHASE COMBINER UNI-DIRECTIONAL METER JURY COURT AC CC PACE M SPCL UTILITY DISCONNECT UTILITY DISCONNECT CHARGE CONTROLLER UTILITY METER EXISTING SUB PANEL CRITICAL LOAD PANEL SHEET # SCALE:819 N LAGOON DRIVEFARMINGTON, UT 84025PHONE: (801) 317-8444DATE:7/19/2024DESIGNER:D HANSENSYSTEM SIZE:14760 WATTSAHJ:Lakeville City, MNRYAN SEYS20980 JURY COURTLAKEVILLE, MINNESOTA 55044SOLARREVISIONS:PROJECT #5-23-2024: R. MIZE13488016-21-202427-19-2024: R. MIZE3N/A4N/A5N/A6PV-07 N.T.S SOURCE CIRCUITS # OF MICROINVERTERS 1 10 2 10 3 10 4 6 FIRE CODE CONCRETE NEMA-4 ROOFTOP JUNCTION BOX ENPHASE COMBINERE AC DISCONNECTAC CHARGE CONTROLLERCC FENCE METER-MAIN PANELM POINT OF INTERCONNECTION NOTE: 1.THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY! 2.ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNEL, WITH PROPER PERSONAL PROTECTIVE EQUIPMENT. 3.AC DISCONNECT SHOULD BE LOCATED TOGETHER IN A READILY ACCESSIBLE LOCATION WITHIN 10' OF THE MAIN SERVICE METER. 4.24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED FOR XCEL ENERGY EQUIPMENT. 5.UTILITY AC DISCONNECT SHOULD BE LOCATED WITHIN 10 FEET OF THE MAIN SERVICE METER. 6.SOLAR PV SHALL BE USED AS A SECONDARY INTERCONNECTION. 7.MAXIMUM 1' SPACING BETWEEN COMPONENTS. 8.NEAREST CROSS ROAD - ELK LAKE RD APPROX. 721' SW NO POSITION, DISTANCE AND CLEARENCE CONCERNS OF OVERHEAD ELECTRIC SERVICE LINES AND/OR OTHER UTILITIES IN RELATION TO THE PV PANELS *MICROINVERTERS ARE MODULE INTEGRATED TOTAL PANELS:36 TOTAL INVERTERS:36 DC SYSTEM SIZE (kW):14.76 kW AC SYSTEM SIZE (kW):13.662 kW SYMBOL:MEANING: JURY COURT PV ARRAY #1 AZIMUTH: 232 TILT: 26.57° # OF MODULE: 32 PV ARRAY #2 AZIMUTH: 52 TILT: 26.57° # OF MODULE: 4 AC CCPAC E M SPCL PRODUCTION METERP CRITICAL LOAD PANELCL UTILITY ACCOUNT #: 51-0013855882-3 UTILITY APPLICATION #: 05765070 1 1 1 SHEET # SCALE:819 N LAGOON DRIVEFARMINGTON, UT 84025PHONE: (801) 317-8444DATE:5/23/2024DESIGNER:D HANSENSYSTEM SIZE:14760 WATTSAHJ:Lakeville City, MNRYAN SEYS20980 JURY COURTLAKEVILLE, MINNESOTA 55044SOLARREVISIONS:PROJECT #5-23-2024: R. MIZE1348801N/A2N/A3N/A4N/A5N/A6MODULE(S) MODULE TYPE NUMBER OF MODS MODULE SIZE: WATTS SYSTEM SIZE: WATTS REC 36 410 14760 WATTS INVERTER(S) MANUFACTURER MODEL NUMBER OF INVERTERS SYSTEM OUTPUT ENPHASE ENERGY IQ8X 36 56.93 AMPS JOB DETAILS ROOF MATERIAL STANDARD ASPHALT SHINGLE ROOF SQ FT OF ARRAY ARRAY AZIMUTH(S)52°,232°756.4 RACKING TYPE UL LISTED IRONRIDGE RACKING SYSTEM ATTACHMENT SPACING MAXIMUM ATTACHMENT SPACING 48'' INSTALLATION SURFACE / PANEL ANGLE 26.57° / 26.57° PV-02 1 16"= 1' COMPACT PANEL Size 9 A module Current compatible with MLPE rec Alpha Pure-R SERIES Product Specifications α experience performance wp430 20.7 w ft2 ELIGIBLE LEAD-FREE rohs cOMPLIANT22.3%Efficiency Ref: PM-DSRev- A .www.recgroup.com Specifications subject to change without notice. STC NMOT85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Lead-Free GR GR GR GR GR 11±0.2[0.43±0.01]6.6±0.2 [0.26±0.01]20.5±0.5[0.8±0.02] 6.0±0.2[0.24±0.01] 1700 [67]1700 [67] Lorem ipsum 1730±2.5 [68.1±0.1] 880 [34.6]425 [16.7]1077±2.5 [42.4±0.1]22.5 [0.9] 594±3 [23.4±0.12] 1118±2.5 [44.0±0.1]17 [0.7]45 [1.8] 30 [1.2]GENERAL DATA Cell type: half-cut REC bifacial, heterojunction cells with lead-free, gapless technology Glass:. in (. mm) solar glass with anti-reflective surface treatment in accordance with EN Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) Junction box:-part, bypass diodes, lead-free IP rated, in accordance with IEC Connectors:Stäubli MC PV KBT /KST ( mm ) in accordance with IEC , IP only when connected Cable: AWG ( mm PV wire, + in (. + . m) in accordance with EN Dimensions:. x . x . in (. ) / x x mm (. m ) Weight:. lbs (. kg) Origin:Made in Singapore WARRANTY Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All kW kW Product Warranty (yrs) Power Warranty (yrs) Labor Warranty (yrs) Power in Year Annual Degradation ... Power in Year See warranty documents for details. Conditions apply TEMPERATURE RATINGS* Nominal Module Operating Temperature:°C (±°C) Temperature coe cient of PMAX:. /°C Temperature coe cient of VOC:. /°C Temperature coe cient of ISC:. /°C *The temperature coe cients stated are linear values MAXIMUM RATINGS Operational temperature: ... +°C System voltage: V Test load (front): + Pa ( lbs/)* Test load (rear):- Pa (. lbs/)* Series fuse rating: A Reverse current: A * See installation manual for mounting instructions. Design load = Test load / . safety factor) ELECTRICAL DATA Product Code*: RECxxxAA PURE R Power Output - PMAX (Wp) Wa Class Sorting - (W)/+/+/+ Nominal Power Voltage - VMPP (V) ... Nominal Power Current - IMPP (A) ... Open Circuit Voltage - VOC (V) ... Short Circuit Current - ISC (A) ... Power Density (W/)... Panel E ciency () ... Power Output - PMAX (Wp) Nominal Power Voltage - VMPP (V) ... Nominal Power Current - IMPP (A) ... Open Circuit Voltage - VOC (V) ... Short Circuit Current - ISC (A) ... Values at standard test conditions (STC: air mass AM ., irradiance . W/sq ( W/m ), temperature °F (°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±% within one wa class. Nominal module operating temperature (NMOT: air mass AM ., irradiance W/m, temperature °F (°C), windspeed . /s ( m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. DELIVERY INFORMATION Panels per pallet: Panels per truck: pallets REC Alpha PURE-R Series Product SPECIFICATIONS Founded in , REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, a ordable solar power. As Solar’s Most Trusted, REC is commi ed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. CERTIFICATIONS PENDING IEC :, IEC :, UL IEC PID IEC Salt Mist IEC Ammonia Resistance UL Fire Type Class IEC Dynamic Mechanical Load IEC :Hailstone (mm) IEC Lead-free acc. to RoHS EU / ISO , ISO , IEC , IEC Typical low irradiance performance of module at STC: LOW LIGHT BEHAVIOUR Measurements in inches [mm] Irradiance (W/m )Rel. Eciency () 6500 Sheridan Drive, Suite 100 Buffalo NY 14221 Phone: 1.866.620.2410 | Toll Free Fax: 1.866.807.7882 | sales@dynoraxx.com www.dynoraxx.com No Tools Required DynoBond™ is pushed onto bottom ange of module. Supports ange thicknesses from 1.2mm to 3.1mm Clean Wire is virtually hidden on system Corrosion Resistant Stainless steel clips and tin-plated copper wire paired for reduced electrochemical potential Superior Design UL recognized to 467 and 2703 DRXDB042214 Stainless Steel Spring Clamp12 Gauge Tin-plated Copper Factory Crimped Connection Teeth Embed into Module Frame Available Wire Lengths t NN t NN t NN t NN t NN 1/12/2024 The DynoRaxx® DynoBond™ is a proprietary UL recognized design that allows the DynoBond™ to be used as a jumper between modules and rows which makes the module frame the medium for the equipment ground path. The DynoBond™ replaces the conventional method of installing one ground lug per solar module and running a solid six gauge copper wire bonding the modules. The DynoBond™ is engineered for commercial and residential applications. www.dynoraxx.com Phone: 1.866.620.2410 sales@dynoraxx.com DYNOBOND™ 1/12/2024 SolaDeck UL 1741 Combiner/Enclosures Model SD 0783-41 3” Fixed Din Rail fastened using Norlock System **Typical System Configuration 4- Din Rail Mounted Fuse Holders 600VDC 30 AMP 1- Power Distribution Block 600VDC 175AMP 1- Bus Bar with UL lug Basic Features •Stamped Seamless Construction • 18 Gauge Galvanized Steel • Powder Coated Surfaces •Flashes into the roof deck •3 Roof deck knockouts .5", .75", 1" •5 Centering dimples for entry/exit fittings or conduit •2 Position Ground lug installed •Mounting Hardware Included Available Models: Model SD 0783 - (3” fixed Din Rail) Model SD 0786 - (6” slotted Din Rail) SolaDeck UL50 Type 3R Enclosures Models SD 0783-41 and SD 0786-41 are labeled and ETL listed UL STD 1741 according to the UL STD 1741 for photovoltaic combiner enclosures. Model SD 0786-41 6” Slotted Din Rail fastened using steel studs **Typical System Configuration 4- Din Rail Mounted Fuse Holders 600VDC 30 AMP 4- Din Rail Mounted Terminal Blocks Bus Bars with UL lug **Fuse holders and terminal blocks added in the field must be UL listed or recognized and meet 600 VDC 30 AMP 110C for fuse holders, 600V 50 AMP 90C for rail mounted terminal blocks and 600 V 175 AMP 90C for Power Distribution Blocks. Use Copper WireConductors. Cover is trimmed to allow conduit or fittings, base is center dimpled for fitting locations. Model SD 0783-41, wired with Din Rail mounted fuse holders, bus bar and power distribution block. Model SD 0786-41, wired with Din Rail mounted fuse holders,terminal blocks and bus bars. RSTC Enterprises, Inc • 2219 Heimstead Road • Eau Cliare, WI 54703 For product information call 1(866) 367-7782 SolaDeck Model SD 0783 Max Rated - 600VDC, 120AMPS 1/12/2024 GE Energy General Duty Safety Switches 30-600 Amps, 240 Vac For residential and light commercial applications ~ UL Listed and CSA Certified ~ Meets or exceeds the requirements of NEMA Standard KS-1 for type General Duty ~ Suitable for use as Service Equipment ~ Fusible and non-fusible construction ~ 100,000 RMS Amps, symmetrical IC rating on 30-200A disconnects when protected by class R fuses ~ NEMA Type 1 (indoor) and Type 3R (outdoor) construction ~ Integral cover interlock on 30-200A disconnects for added protection ~ Lockable cover and handle (OFF position) to prevent unauthorized entry and use ~ Field installable accessories available (ground lugs, neutral lugs, class R fuse rejection kits, and universal raintight hubs) Features & Benefits Ordering Information Fusible Non- Fusible NEMA Type 1 (indoor) Ampere Rating 2-Pole 3-Wire 3-Pole 3-Wire 3-Pole 4-Wire 3-Pole 3-Wire 30 TG3221 — TG4321 TGN3321 60 TG3222 — TG4322 TGN3322 100 TG3223 — TG4323 TGN3323 200 TG3224 — TG4324 TGN3324 400 TG3225 TG3325 TG4325 TGN3325 600 TG3226 TG3326 TG4326 TGN3326 Fusible Non- Fusible NEMA Type 3R (outdoor) Ampere Rating 2-Pole 3-Wire 3-Pole 3-Wire 3-Pole 4-Wire 3-Pole 3-Wire 30 TG3221R — TG4321R TGN3321R 60 TG3222R — TG4322R TGN3322R 100 TG3223R — TG4323R TGN3323R 200 TG3224R — TG4324R TGN3324R 400 TG3225R TG3325R — — 600 TG3226R TG3326R — — *Includes factory installed neutral lug TGN3322 with integral cover interlock **** 30A 60A 100A 200A Now with cover interlock! imagination at work DEE-576 7/12 GE Energy 41 Woodford Avenue Plainville, CT 06062 www.geindustrial.com © 2012 GE Company Information provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end-use conditions. 1/12/2024 Flush Mount System Strength Tested All components evaluated for superior structural performance. PE Certified Pre-stamped engineering letters available in most states. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Design Assistant Online software makes it simple to create, share, and price projects. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. 25-Year Warranty Products guaranteed to be free of impairing defects. Built for solar’s toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 25-year warranty. Datasheet 1/12/2024 © 2018 IronRidge, Inc. All rights reserved. U.S. Patents: #8,695,290; #9,819,303; #9,865,938; Others Pending. Version 1.50 XR Rails Attachments Datasheet Design Assistant Go from rough layout to fully engineered system. For free. Go to IronRidge.com/design Resources XR100 Rail The ultimate residential solar mounting rail. • 8’ spanning capability • Heavy load capability • Clear and black finish Bonded Splices All rails use internal splices for seamless connections. • Self-drilling screws • Varying versions for rails • Forms secure bonding XR10 Rail A low-profile mounting rail for regions with light snow. • 6’ spanning capability • Moderate load capability • Clear and black finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12’ spanning capability • Extreme load capability • Clear anodized finish FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist-on Cap eases install • Wind-driven rain tested • Mill and black finish Drop-in design for rapid rail attachment. • Secure rail connections • Slot for vertical adjusting • Clear and black finish Slotted L-Feet Clamps & Grounding UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear and black finish Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • Sized to match modules • Clear and black finish Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction Microinverter Kits Mount MIs or POs to XR Rails. • Bonds devices to rails • Kit comes assembled • Listed to UL 2703 NABCEP Certified Training Earn free continuing education credits, while learning more about our systems. Go to IronRidge.com/training Bond and attach XR Rails to roof attachments. • T & Square Bolt options • Nut uses 7/16” socket • Assembled and lubricated Bonding Hardware CONTINUING EDUCAT IONREGISTERED PROVIDER Flash and mount conduit, strut, or junction boxes. • Twist-on Cap eases install • Wind-driven rain tested • Secures ¾” or 1” conduit Conduit Mount 1/12/2024 MODULe COMPATIBILITY © 2023 IRONRIDGE, INC. VERSION 4.1 FLUSH MOUNT INSTALLATION MANUAL - 27 Phono Solar Phono Solar modules with 30, 35 and 40 mm frames PSxxxY-ZZ/A Where "Y" can be M, M1, MH, M1H, M4, M4H, M5GF, M5GFH, M6, M6H, M8, M8H, M8GF, M8GFH or P; "ZZ" can be 18, 20 or 24; and "A" can be F, T, TH, THB, U, UH, UHB, VH or VHB Prism Solar Prism Solar modules with 35 mm frames PST-xxxW-M72Y Where "Y" can be H, HB or HBI Rayzon Solar Rayzon Solar modules with 35 and 40 mm frames RSxxxWC Recom Recom modules with 35 and 40 mm frames RCM-xxx-6yy Where “yy” can be MA, MB, ME or MF REC Solar REC modules with 30 and 38 mm frames RECxxxYYZZ Where “YY” can be AA, M, NP, NP2, NP3, PE, PE72, TP, TP2, TP2M, TP2SM, TP2S, TP3M or TP4; and “ZZ” can be blank, Black, BLK, BLK2, SLV, 72, Pure, Pure-R, Pure-RX or Pure 2 Renesola ReneSola modules with 35 and 40 mm frames AAxxxY-ZZ Where "AA" can be SPM(SLP) or JC; "Y" can be blank, F, M or S; and "ZZ" can be blank, Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, Db-b, or 24/Bb Renogy Renogy Modules with 35 and 40 mm frames RZZ-xxxY-AAA Where "ZZ" can be NG or SP; "Y" can be D or P; and "AAA" can be blank, 144, BB-108, BB-120 or BK-120 Risen Risen Modules with 30, 35 and 40 mm frames RSMyy-a-xxxZZ Where "yy" can be 60, 72, 110, 120, 132 or 144; "a" can be 6, 7 or 8; and "ZZ" can be M, P or BMDG Saatvik Saatvik Modules with 35 mm frames SGExxx-YYYZZZ Where "YYY" can be 108 or 144; and "ZZZ" can be MHC, MBHC or MHCB S-Energy S-Energy modules with 35 and 40 mm frames SABB-CCYYY-xxxZ Where “A” can be C, D, L or N; “BB” can be blank, 20, 25, 40 or 45; “CC” can be blank, 60 or 72; “YYY” can be blank, BDE, MAE, MAI, MBE, MBI, MCE or MCI; and “Z” can be V, M-10, P-10 or P-15 SEG Solar SEG Solar with 30, 35 and 40 mm frames SEG-aYY-xxxZZ Where "a" can be blank, 6 or B; "YY" can be blank, MA, MB, PA, or PB; and "ZZ" can be blank, BB, BG, BW, HV, WB, WW, BMB, BMA-HV, BMA-BG, BMA-TB, BMB-TB, BMB-HV, BMD-HV, BMB-BG, BTA-BG or BMD- TB Seraphim USA Seraphim modules with 30, 35 and 40 mm frames SRP-xxx-YYY-ZZ Where "xxx" is the module power rating; and "YYY" can be BMA, BMD, 6MA, 6MB, 6PA, 6PB, 6QA-XX-XX, and 6QB-XX-XX; ZZ is blank, BB, BG or HV Sharp Sharp modules with 35 and 40 mm frames NUYYxxx Where “YY” can be SA or SC Shinsung E&G Shinsung Modules with 35 mm frames SSVxxx-144MH Silfab Silfab Modules with 35 and 38 mm frames SYY-Z-xxxAb Where "YY" can be IL, SA, LA, SG or LG; "Z" can be blank, M, P, or X; "A" can be blank, B, H, M, N; and "b" can be A, C, C+, G, K, L, M, N, T, U or X Cut Sheet © 2023 IronRidge, Inc. All rights reserved. Visit www.ir-patents.com for patent information.QM-HUG-01-B1 or QM-HUG-01-M1 Cut Sheet Rev 1.01 1 RD STRUCTURAL SCREW PN RD-1430-01-M1 SOLD SEPARATELY SHOWN FOR REFERENCE Release Liner shown for reference ITEM NO DESCRIPTION QTY IN KIT 1 QM Halo UltraGrip(Mill or Black)1 PART NUMBER DESCRIPTION QM-HUG-01-M1 Halo UltraGrip - Mill QM-HUG-01-B1 Halo UltraGrip - Black QuickMount® Halo UltraGrip® Cut Sheet © 2023 IronRidge, Inc. All rights reserved. Visit www.ir-patents.com for patent information.QM-HUG-01-B1 or QM-HUG-01-M1 Cut Sheet Rev 1.01 3.83 .38 3.35 1.63 3.00 .40 .34 .26 1.56 1. Halo UltraGrip Property Value Material 300 Series Aluminium Finish Mill or Black DATASHEET IQ8X Microinverter Our newest IQ8 Series Microinverters are the industry’s first microgrid-forming*, software-defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application- specific integrated circuit (ASIC), which enables the microinverter to operate in grid-tied or off- grid mode. This chip is built using the advanced 55 nm technology with high-speed digital logic and superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. *Only when installed with IQ System Controller 1, 2, or 3, meets UL 1741. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL Listed as PV rapid shutdown equipment and conform with regulations when installed according to the manufacturer’s instructions. Connect PV modules quickly and easily to the IQ8 Series Microinverters with integrated MC4 connectors. Easy to install • Lightweight and compact with plug- and-play connectors • Power line communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produces power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB) • Designed to support PV modules with higher input DC voltage and cell counts, such as 96-cell, 80-half-cell, and 88-half-cells. NOTE: IQ8 Series Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, and so on) in the same system. PRELIMINARY IQ8X-MC4-DSH-00185-1.0-EN-US-2023-09-26 © 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. (1) No enforced DC/AC ratio. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. (4) IQ8X is not certified for use with Enphase Three Phase Network Protection Relay (NPR-3P-208-NA) and therefore designed for single-phase operation only. Check with the local utility requirements if you wish to install single phase inverter across three phases. IQ8X Microinverter INPUT DATA (DC)UNIT IQ8X-80-M-US Commonly used module pairings 1 W 320–540 Module compatibility To meet compatibility, PV modules must be within max. input DC voltage and max. module Isc listed below. Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator MPPT voltage range V 43–60 Operating range V 25–79.5 Min. and max. start voltage V 30–79.5 Max. input DC voltage V 79.5 Max. continuous operating DC current A 10 Max. input DC short-circuit current A 16 Max. module Isc A 13 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration Ungrounded array; no additional DC side protection required; AC side protection requires max. 20 A per branch circuit OUTPUT DATA (AC)UNIT IQ8X-80-M-US @240 VAC IQ8X-80-M-US @208 VAC Peak output power VA 384 366 Max. continuous output power VA 380 360 Nominal grid voltage (L-L)V 240, split-phase (L-L), 180°208, single-phase (L-L), 120° 4 Min. and max. grid voltage 2 V 211–264 183–229 Max. continuous output current A 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 47–68 AC short circuit fault current over three cycles Arms 2.70 Max. units per 20 A (L-L) branch circuit 3 10 9 Total harmonic distortion %<5 Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading…0.85 lagging Peak efficiency %97.6 97.4 CEC weighted efficiency %97 96.5 Nighttime power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to 65°C (-40°F to 149°F) Relative humidity range 4% to 100% (condensing) DC connector type Stäubli MC4 Dimensions (H × W × D); Weight 212 mm (8.3") × 175 mm (6.9") × 30.2 mm (1.2"); 1.1 kg (2.43 lbs) Cooling Natural convection – no fans Approved for wet locations; Pollution degree Yes; PD3 Enclosure Class II double-insulated, corrosion-resistant polymeric enclosure Environmental category; UV exposure rating NEMA Type 6; outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer’s instructions. IQ8X-MC4-DSH-00185-1.0-EN-US-2023-09-26 Revision history REVISION DATE DESCRIPTION DSH-00185-1.0 September 2023 Preliminary release IQ8X-MC4-DSH-00185-1.0-EN-US-2023-09-26 © 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. DATASHEET IQ System Controller 3/3G The Enphase IQ System Controller 3/3G connects the home to grid power, the IQ Battery system, and solar PV. It provides microgrid interconnect device (MID) functionality by automatically detecting and seamlessly transitioning the home energy system from grid power to backup power in the event of a grid failure. It consolidates interconnection equipment into a single enclosure and streamlines grid-independent capabilities of PV and storage installations by providing a consistent, pre-wired solution for residential applications. Easy to install • Connects to service entrance¹ or main load center • Includes neutral-forming transformer • Mounts on single stud with centered brackets • Provides conduit entry from the bottom, left, or right • Includes color-coded wires for ease of wiring the System Shutdown Switch • Integrates hold-down functionality to eliminate the need for hold-down kits and special breakers Flexible • Can be used for Sunlight Backup, Home Essentials Backup, or Full Energy Independence • IQ System Controller 3 integrates with IQ Battery 5P • IQ System Controller 3G integrates with select AC standby generators. See the Generator integration tech brief for a list of generators • Provides a seamless transition to backup Safe and reliable • System Shutdown Switch can be used to disconnect PV, battery, and generator systems • System Shutdown Switch acts as a rapid shutdown initiator of grid-forming IQ8 PV Microinverters for the safety of maintenance technicians/first responders • 10-year limited warranty (1) IQ System Controller 3 is not suitable for use as service equipment in Canada. IQSC-3-DSH-00021-3.0-EN-US-2023-08-08 © 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. IQ Combiner 5/5C Consolidates PV interconnection equipment into a single enclosure and streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, pre-wired solution for residential applications IQ Series Microinverters The high-powered smart grid-ready IQ Series Microinverters (M Series, IQ6, IQ7, and IQ8 Series) dramatically simplify the installation process 10-year limited warranty IQ Load Controller Helps prioritize essential appliances during a grid outage to optimize energy consumption and prolong battery life IQ Battery 5P Fully integrated AC battery system. Includes six field-replaceable IQ8D-BAT microinverters (4) The IQ System Controller 3 is rated at 22 kAIC. (5) Integrated hold-down kit support breakers (BR230/BR230/BR240) without predrilled hole. Integrated hold-down kit also supports GE/ABB and Siemens as mentioned under section alternate DER circuit breakers. (6) "~" indicates alternating current (AC) supply. (*) Power Control System. IQ System Controller 3/3G MODEL NUMBER DESCRIPTION SC200D111C240US01 IQ System Controller 3 streamlines the grid-independent capabilities of PV and storage installations. Integrates hold-down capability. Supports IQ Battery 5P units up to 40 kWH (without PCS*) and 80 kWh (with PCS*). Does not support generator integration SC200G111C240US01 IQ System Controller 3G streamlines the grid-independent capabilities of PV and storage installations. Integrates hold-down capability. Supports IQ Battery 5P units up to 20 kWH (without PCS*) and 40 kWh (with PCS*). Supports generator integration WHAT'S IN THE BOX IQ System Controller 3/3G Includes neutral-forming transformer (NFT) and microgrid interconnect device (MID) System Shutdown Switch Includes pre-wired red, black, orange, and purple 12 AWG wire (EP200G-NA-02-RSD) Wall-mounting bracket Screws provided in the accessories kit for mounting 4-pole circuit breaker Pre installed Quad breaker (BRK-20A40A-4P-240V), 20 A-40 A, 10 kAIC, Eaton BQC2202402 Accessories kit IQ System Controller 3/3G literature kit, including labels, CTRL headers, screws, filler plates, and Quick Install Guide (QIG) (EP200G-LITKIT) OPTIONAL ACCESSORIES AND REPLACEMENT PARTS CT-200-SPLIT 200 A split core current transformers for metering (accuracy: ±2.5%)³ CT-200-CLAMP 200 A clamp-type current transformers for metering (accuracy: ±2.5%)³ Main or load circuit breakers (order separately, as needed)4 • BRK-100A-2P-240V : 2-pole, 100A, 25kAIC, CSR2100N or CSR2100 • BRK-125A-2P-240V: 2-pole, 125A, 25kAIC, CSR2125N • BRK-150A-2P-240V: 2-pole, 150A, 25kAIC, CSR2150N • BRK-175A-2P-240V: 2-pole, 175A, 25kAIC, CSR2175N • BRK-200A-2P-240V: 2-pole, 200A, 25kAIC, CSR2200N Distributed energy resource (DER) circuit breakers (order separately, as needed)5 • BRK-20A-2P-240V-B: 2-pole, 20 A, 10 kAIC, BR220B/BR220 • BRK-30A-2P-240V-B: 2-pole, 30 A, 10 kAIC, BR230 • BRK-40A-2P-240V-B: 2-pole, 40 A, 10 kAIC, BR240B/BR240 • BRK-60A-2P-240V: 2-pole, 60 A, 10 kAIC, BR260 • BRK-80A-2P-240V: 2-pole, 80 A, 10 kAIC, BR280 EP200G-HNDL-R1 IQ System Controller 3/3G installation handle kit (order separately) CTRL-SC3-NA-01 Control cable, 500 ft. spool (order separately) ALTERNATE DER CIRCUIT BREAKERS GE/ABB THQL21xx (20/40/60/80 A) Siemens Q2xx (20/40/60/80 A) Siemens (quad breaker) Q24020CT2 (20/40 A) ELECTRICAL SPECIFICATIONS Nominal voltage/Range (L-L)240 V~6/±20% Voltage measurement accuracy ±1% V nominal (±1.2V L-N and ±2.4V L-L) Auxiliary (dry) contact for load control, excess PV control, and generator two-wire control 24 V, 1 A Nominal frequency/Range 60 Hz/56–63 Hz Frequency measurement accuracy ±0.1 Hz Maximum continuous current rating 160 A Maximum input overcurrent protection device 200 A Maximum output overcurrent protection device 200 A Maximum overcurrent protection device rating for generator circuit 80 A (IQ System Controller 3G only - SC200G111C240US01) Maximum overcurrent protection device rating for storage circuit 2 x 80 A (IQ System Controller 3 - SC200D111C240US01), 1 x 80 A (IQ System Controller 3G - SC200G111C240US01 ) DATASHEET (2) Factory installed quad breaker (Siemens or Eaton). NFT pre-wired to 40 A terminal of the quad breaker. (3) Two units of CT-200-SPLIT or CT-200-CLAMP must be bought separately for generator integration. IQSC-3-DSH-00021-3.0-EN-US-2023-08-08 ELECTRICAL SPECIFICATIONS Maximum overcurrent protection device rating for PV combiner unit 80 A Internal busbar rating 200 A Neutral-forming transformer (NFT)• Breaker rating (pre-installed): 40 A between L1 and Neutral; 40 A between L2 and Neutral • Continuous rated power: 3,600 VA • Maximum continuous unbalance current: 30 A @ 120 V • Peak unbalanced current: 80 A @ 120 V for two seconds MECHANICAL DATA Dimensions (WxHxD)50 cm x 91.6 cm x 24.6 cm (19.7 in x 36 in x 9.7 in) Weight 39.4 kg (87 lbs) Ambient temperature range -40°C to 50°C (-40°F to 122°F) Cooling Natural convection and a heat shield Enclosure environmental rating Outdoor, NEMA type 3R, polycarbonate construction Maximum altitude 2500 meters (8200 feet) WIRE SIZES Connections (All lugs are rated to 90°C) Main lugs and backup load lugs CSR breaker bottom wiring lugs AC combiner lugs, IQ Battery lugs, and generator lugs Neutral (large lugs) Cu/Al: 6 AWG–300 kcmil Cu/Al: 2 AWG–300 kcmil 14 AWG–2 AWG Cu/Al: 6 AWG–300 kcmil Neutral and ground bars Large holes (5/16–24 UNF) Small holes (10–32 UNF) 14 AWG–1/0 AWG 14 AWG–6 AWG COMPLIANCE Compliance (under progress) UL 1741, UL 1741 SA, IEEE 1547:2018 (UL 1741-SB, 3rd Ed.), UL 1741 PCS CRD, UL1 998, UL 869A, UL 675, UL 5087, UL 50E7 CSA 22.2 No. 107.1, 47 CFR Part 15 Class B, ICES 003, ICC ES AC156. The IQ System Controller 3/3G is approved for use as service equipment in the United States WARRANTY Limited warranty (restrictions apply) Up to 10 years (EP200G-NA-02-RSD has a 5-year warranty) COMPATIBILITY8 Battery IQ Battery 5P (IQBATTERY-5P-1P-NA) Microinverters IQ8, IQ7, IQ6, and M Series Microinverters9 IQ Combiner IQ Combiner 5/5C (X-IQ-AM1-240-5C,  X-IQ-AM1-240-5) Communications Kit 2 COMMS-KIT-02 (7) Sections from these standards were used during the safety evaluation and included in the UL 1741 listing. (8) For more details, refer to IQ System Controller 3/3G Quick Install Guide. (9) M Series Microinverters can only be supported in states that have not yet adopted IEEE 1547:2018. Enphase does not support mixing IQ8 Series Microinverters with other series on the same IQ Gateway. DATASHEET IQSC-3-DSH-00021-3.0-EN-US-2023-08-08 STRUCTURAL CERTIFICATION REPORT July 16, 2024 To: 1Solar Re: Ryan Seys 2391 S. 1560 W Suite C 20980 Jury Ct Woods Cross, UT 84087 Lakeville, MN 55044 AHJ: Lakeville (City), MN proposes to install new roof-mounted solar panels at this residence and asked to review the existing structure for suitability. This letter summarizes the methods that were used to survey, evaluate, and certify the existing roof framing and the attachment of the new solar panels to it. STRUCTURAL DESIGN Building Code:Minnesota Residential Code 2020 Design Standards:ASCE 7-16 Snow:Ground: pg= 60.0 psf | Flat Roof: pf= 41.58 psf | Sloped Roof: ps= 30.49 psf Wind:Ultimate Wind Speed = 109.0 mph | Exposure = C Seismic:Risk Category = 2 | Seismic Design Category = A | Site Class = D STRUCTURE Field Technicians from visited the site and observed the existing structure : Array Name Panel Quantity Roof Framing Material Pitch Array 1 2 Pre-Manufactured Truss| 24" o.c.Asphalt Shingles 26° Array 2 4 Pre-Manufactured Truss| 24" o.c.Asphalt Shingles 26° Array 3 10 Pre-Manufactured Truss| 24" o.c.Asphalt Shingles 26° Array 4 20 Pre-Manufactured Truss| 24" o.c.Asphalt Shingles 26° ANCHORAGE The solar panel anchorage shall be installed according to the manufacturer's most current installation manual. The attachment configuration should match the certified building plans. The solar panels should be mounted parallel (max 5 inches) to the roof surface. Array Name Connection Type Fastener Max Anchorage Spacing Array 1 Halo UltraGrip (HUG) (2) #14 Wood Screws (2.5" embedment) into roof substructure 48" Array 2 Halo UltraGrip (HUG) (2) #14 Wood Screws (2.5" embedment) into roof substructure 48" Array 3 Halo UltraGrip (HUG) (2) #14 Wood Screws (2.5" embedment) into roof substructure 48" Array 4 Halo UltraGrip (HUG) (2) #14 Wood Screws (2.5" embedment) into roof substructure 48" Installation Instructions Solar panels and the equipment shall be installed per the manufacturer's installation specifications. Improper installation will void this certification. If deviations from the approved structural plans occur, Right Angle Engineering must be notified. Prior to installation, the installer should: 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 1 of 7 •Confirm that the existing structure matches the information provided in the site survey, the approved installation plans and this certification. •Identify discrepancies between this certification and the approved installation plans. If found, then this certification shall govern. •Identify structural elements that are dangerous (cracked, broken, excessive sag, signs of overstress, rot,decay, fire, water). If found, installation shall cease until those elements are adequately abated and made to comply with the referenced building code. •Verify that both the existing structure and the solar addition has been permitted through the AHJ. STRUCTURAL CERTIFICATION I certify the addition of solar panels on the roof of this structure does not cause the structure to become unsafe or make it generally less compliant with the life-safety requirements of the referenced building code. Based on the evaluation methods described below, for the loads that exist at this site, the existing framing will safely support the new solar panels if they are installed and attached correctly. Electrical design is not included in this certification. Array Name Certification Method Retrofits Array 1 Prescriptive method Minnesota Conservation Code for Existing Buildings code 806.2 None required Array 2 Prescriptive method Minnesota Conservation Code for Existing Buildings code 806.2 None required Array 3 Prescriptive method Minnesota Conservation Code for Existing Buildings code 806.2 None required Array 4 Prescriptive method Minnesota Conservation Code for Existing Buildings code 806.2 None required Regards, Robert D. Smythe, P.E. Right Angle Engineering 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 2 of 7 Job Details Roof Snow Load - ASCE 7-16 Ground Snow Load ()60.0 psf Exposure Factor ()0.9 Thermal Factor ()1.1 Importance Factor ()1 Flat Roof Snow Load ()41.58 psf Non-Slippery Surface Slope Factor () 1 Slippery Surface Slope Factor ()0.73 Roof Snow Load 41.58 psf Reduced Snow Load (Slippery Surface)30.49 psf Design Criteria Wind Speed (Vult)109.0mph Exposure Category C Risk Category 2 Mean Roof Height 20 ft Roof Type Gable Roof Building Type Enclosed Roof Live Load Existing Roof Live Load 20 psf 1Roof Dead Load Asphalt Shingles 2.0 psf No Drywall 0.0 psf 5/8" Plywood Sheathing 2.0 psf Solar Panel Array 2.74 psf Roof Framing 4 psf Dead Load Without Panels 9.2 psf Insulation 1.2 psf 1Roof Dead Load is taken from the worst case scenario dead load from all arrays of the job in order to provide a more conservative evaluation. 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 3 of 7 Array 1 Array Details Roof Framing Pre-Manufactured Truss Spacing 24.0" Beam Span 24.0' Roof Pitch 26° Panel Quantity 2 Panel Array Area 43.27 ft² Panel Orientation Portrait Lag Screw Embedment 2.5" Roof Attachment Type Halo UltraGrip (HUG) (2) #14 Wood Screws Shear Capacity 368.0 lbs Pullout Capacity 1004.0 lbs Velocity Pressure 22.43 psf GCP Zones 1/2e 2n/2r /3e 3r GCp -1.48 -2.13 -2.4 Design Pressure Up [psf]-17.7 -25.5 -28.7 Factored Design Pressure Up [psf]-9.1 -13.8 -15.7 Exposed Design Pressure Up [psf]-26.5 -38.2 -43.0 Design Pressure Down [psf]16 16 16 Tributary Area [ft2]25.3 25.3 25.3 Maximum Connection Spacing [in]97 97 97 Maximum Rail Span [in]48 48 48 Maximum Rail Cantilever [in]16 16 16 Design Connection Spacing [in]48 48 48 Design Connection Spacing (exposed) [in]48 48 48 Prescriptive Method: Minnesota Conservation Code for Existing Buildings Code 806.2 Total load on member without solar 2589.78 lbs Total load on member with solar 2380.92 lbs Percentage of total design load on member with solar 0.92% The 2020 Minnesota Conservation Code for Existing Buildings section 806.2 indicates that alterations to an existing building that results in less than a 5.0% increase in the total stress may be performed without a structural evaluation of the existing building. As demonstrated in the above calculations, the additional weight of the solar panels will be less than 5.0% increase in the gravity loading and therefore stress on the existing roof framing. Load case before and load case after solar panels have been added have both been considered according to Minnesota State Building Code 1607.13.5.1. 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 4 of 7 Array 2 Array Details Roof Framing Pre-Manufactured Truss Spacing 24.0" Beam Span 32.0' Roof Pitch 26° Panel Quantity 4 Panel Array Area 86.54 ft² Panel Orientation Portrait Lag Screw Embedment 2.5" Roof Attachment Type Halo UltraGrip (HUG) (2) #14 Wood Screws Shear Capacity 368.0 lbs Pullout Capacity 1004.0 lbs Velocity Pressure 22.43 psf GCP Zones 1/2e 2n/2r /3e 3r GCp -1.48 -2.13 -2.4 Design Pressure Up [psf]-17.7 -25.5 -28.7 Factored Design Pressure Up [psf]-9.1 -13.8 -15.7 Exposed Design Pressure Up [psf]-26.5 -38.2 -43.0 Design Pressure Down [psf]16 16 16 Tributary Area [ft2]25.3 25.3 25.3 Maximum Connection Spacing [in]97 97 97 Maximum Rail Span [in]48 48 48 Maximum Rail Cantilever [in]16 16 16 Design Connection Spacing [in]48 48 48 Design Connection Spacing (exposed) [in]48 48 48 Prescriptive Method: Minnesota Conservation Code for Existing Buildings Code 806.2 Total load on member without solar 3402.26 lbs Total load on member with solar 3193.4 lbs Percentage of total design load on member with solar 0.94% The 2020 Minnesota Conservation Code for Existing Buildings section 806.2 indicates that alterations to an existing building that results in less than a 5.0% increase in the total stress may be performed without a structural evaluation of the existing building. As demonstrated in the above calculations, the additional weight of the solar panels will be less than 5.0% increase in the gravity loading and therefore stress on the existing roof framing. Load case before and load case after solar panels have been added have both been considered according to Minnesota State Building Code 1607.13.5.1. 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 5 of 7 Array 3 Array Details Roof Framing Pre-Manufactured Truss Spacing 24.0" Beam Span 32.0' Roof Pitch 26° Panel Quantity 10 Panel Array Area 216.35 ft² Panel Orientation Portrait Lag Screw Embedment 2.5" Roof Attachment Type Halo UltraGrip (HUG) (2) #14 Wood Screws Shear Capacity 368.0 lbs Pullout Capacity 1004.0 lbs Velocity Pressure 22.43 psf GCP Zones 1/2e 2n/2r /3e 3r GCp -1.48 -2.13 -2.4 Design Pressure Up [psf]-17.7 -25.5 -28.7 Factored Design Pressure Up [psf]-9.1 -13.8 -15.7 Exposed Design Pressure Up [psf]-26.5 -38.2 -43.0 Design Pressure Down [psf]16 16 16 Tributary Area [ft2]25.3 25.3 25.3 Maximum Connection Spacing [in]97 97 97 Maximum Rail Span [in]48 48 48 Maximum Rail Cantilever [in]16 16 16 Design Connection Spacing [in]48 48 48 Design Connection Spacing (exposed) [in]48 48 48 Prescriptive Method: Minnesota Conservation Code for Existing Buildings Code 806.2 Total load on member without solar 3402.26 lbs Total load on member with solar 3088.96 lbs Percentage of total design load on member with solar 0.91% The 2020 Minnesota Conservation Code for Existing Buildings section 806.2 indicates that alterations to an existing building that results in less than a 5.0% increase in the total stress may be performed without a structural evaluation of the existing building. As demonstrated in the above calculations, the additional weight of the solar panels will be less than 5.0% increase in the gravity loading and therefore stress on the existing roof framing. Load case before and load case after solar panels have been added have both been considered according to Minnesota State Building Code 1607.13.5.1. 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 6 of 7 Array 4 Array Details Roof Framing Pre-Manufactured Truss Spacing 24.0" Beam Span 28.0' Roof Pitch 26° Panel Quantity 20 Panel Array Area 432.7 ft² Panel Orientation Portrait Lag Screw Embedment 2.5" Roof Attachment Type Halo UltraGrip (HUG) (2) #14 Wood Screws Shear Capacity 368.0 lbs Pullout Capacity 1004.0 lbs Velocity Pressure 22.43 psf GCP Zones 1/2e 2n/2r /3e 3r GCp -1.48 -2.13 -2.4 Design Pressure Up [psf]-17.7 -25.5 -28.7 Factored Design Pressure Up [psf]-9.1 -13.8 -15.7 Exposed Design Pressure Up [psf]-26.5 -38.2 -43.0 Design Pressure Down [psf]16 16 16 Tributary Area [ft2]25.3 25.3 25.3 Maximum Connection Spacing [in]97 97 97 Maximum Rail Span [in]48 48 48 Maximum Rail Cantilever [in]16 16 16 Design Connection Spacing [in]48 48 48 Design Connection Spacing (exposed) [in]48 48 48 Prescriptive Method: Minnesota Conservation Code for Existing Buildings Code 806.2 Total load on member without solar 2996.02 lbs Total load on member with solar 2578.29 lbs Percentage of total design load on member with solar 0.86% The 2020 Minnesota Conservation Code for Existing Buildings section 806.2 indicates that alterations to an existing building that results in less than a 5.0% increase in the total stress may be performed without a structural evaluation of the existing building. As demonstrated in the above calculations, the additional weight of the solar panels will be less than 5.0% increase in the gravity loading and therefore stress on the existing roof framing. Load case before and load case after solar panels have been added have both been considered according to Minnesota State Building Code 1607.13.5.1. 757 Technology Ave, F31 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 7 of 7