RESIDENTIAL BUILDING PERMIT APPLICATION
PAGE 2
OFFICE USE ONLY
BUILDING PERMIT TYPE REQUIRED INSPECTIONS
SINGLE FAMILY DWELLING BUILDING
DUPLEX AS BUILT
TOWNHOUSE UNITS BUILDING FINAL
DETACHED TOWN HOUSE UNIT
CONDO
REROOF
RESIDE
RES ADDN/REPAIR/RMDL
DECK
PORCH
GARAGES
LOWER LEVEL FINISH
ADDITION
FOUNDATION ONLY
MISCELLANEOUS
DEMO
APPROVED BY:
BUILDING INSPECTOR: Date:
PLUMBING/MECHANICAL
INSPECTOR: Date:
COMMENTS:
CITY BUILDING VALUATION: $
BUILDING PERMIT FEES
$PERMIT FEE
$PLAN CHECK
$SURCHARGE
$METRO SAC
$CITY WATER HOOKUP UNIT
$CITY SEWER HOOKUP UNIT
$LANDSCAPE ESCROW
$TREE ESCROW
$MISC ESCROW
$PLUMBING
$MECHANICAL
$SEWER WATER
WATER METER
PRESSURE REDUCING VALVE
$OTHER
$TOTAL
METER SIZE
PRESSURE REDUCING VALVE
SEWER/WATER
SEWER/WATER
FINAL
STREET DRAINTILE
BUILDING INFORMATION
TYPE OF CONSTRUCTION
ZONING
CODE EDITION
FIRE SUPPRESSION SYSTEM
OCCUPANCY GROUP
MECHANICAL
AIR TEST
FINAL
ROUGH-IN
PLUMBING
FINAL
ROUGH-IN
INSULATION
LATH
DECK FOOTING
FIREPLACE
FOOTING
FOUNDATION
FRAMING
PORCH FRAMING
PORCH FOOTING
POURED WALL
SITE
LOWER LEVEL FINAL
OTHER
DECK FRAMING
LOWER LEVEL FRAMING
LANDSCAPING
DECK FINAL
$
$
ACCESSORY BUILDING
EGRESS WINDOW
UNDERGROUND
Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode08/05/2024jnuetzman
SmokeSmokeCOSmokeSmokeCOFANFANFANSmokeSmokeSmokeSmokeCOFANCS-PFCS-PF-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).10.7510.752.53.7518.17.5918.150" WSP5.7524.5UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.(2)7-1/4 LVL(2)7-1/4 LVL(2)7-1/4 LVL(2)7-1/4 LVL
(2)7-1/4 LVL Girder Truss(2)7-1/4 LVL(2)9-1/2 LVLGirder (2)7-1/4 LVL
Project Name:Lateral Brace Wall ReviewProject #:24-093Site Address:17774 Embers AveOswell Engineeringand Consulting, L.L.C.Page S1 of S4Lakeville, MNI hereby certify that this plan,specification, or report wasprepared by me or under mydirect supervision and that I ama duly licensed professionalengineer under the laws of thestate of Minnesota.Craig Oswell, PE (MN #42341) 7/31/20241901 E Hennepin Ave, #201Minneapolis, MN 55413Phone: 612-720-4639Fax: 612-886-2966www.oswellec.comSCOPE & NOTESClient Name:Pinnacle Family HomesISSUED FOR CONSTRUCTIONSCOPE OF WORK:Structural engineering design and detailing for the lateral brace wall requirements at a proposed single-familyresidence. Design is in accordance with the 2020 Minnesota State Building Code and the amended 2018International Residential Code. The scope is limited to the new specific structural items noted. Means andmethods of construction and all other non-structural items are to be by others as required per the Code andstandard industry practice. Refer to the architectural drawings for more information.NOTES:1.The details and plans contained in these drawings are illustrative only and all dimensions areapproximate. The contractor is to verify all conditions and dimensions noted and is to contact theengineer prior to performing the affected work should any significant discrepancies be found.2.This design review was performed in accordance with IRC section R602.10 as applicable using anultimate wind load of 115 mph (90 mph allowable) with an exposure category of B. Portions of the lowerlevel so not require bracing due to the layout of the foundation and grade.3.Follow all manufacturer requirements for hardware and materials.4.All wood in contact with masonry or concrete or in an exterior environment is to be treated or otherwiseseparated.5.Anchor bolts for walkout and frost walls are to be 0.5" diameter at 72" on center maximum with standardwashers and at least 7" embed placed at least 2" from the bolt center to the edge of both the sill plateand foundation wall.6.Anchor bolts for full height walls are to be 0.5" diameter spaced per Code or other standard design with0.125" thick x 2" round/square countersunk washers and at least 7" embed placed at least 2.5" from thebolt center to the edge of both the sill plate and foundation wall.7.Install an anchor bolt within 12" of all sill plate ends with at least two bolts for sections over 24" long.8.Sill plates may overhang up to 1.5" provided all anchor bolt tolerances are met, the sill plate overhang isnot loaded vertically, and all post bearings are checked for crushing on the sill portion over the concreteonly. Increase the sill plate width as required to meet these limits.9.Unless noted otherwise, the opposite face of all shear wall panels, as well as the over-sheathing atinterior panels with plywood or OSB, are to be sheathed with 1/2" sheetrock or better with standardfastening.10.Unless otherwise noted, the exterior faces of all exterior walls, including above and below openings, areto be sheathed continuously with 7/16" minimum thick OSB or plywood nailed with 8d (0.131" diameter x2.5") nails at 6" on center at all panel edges and at 12" on center in the field. Exterior wall sheathing is toextend to the roof line at gables.11.Unless noted otherwise, all horizontal sheathing edges at the panel locations along the brace lines onlyare to be fastened to 2x full width horizontal blocking.12.The roof is to be sheathed with 7/16" minimum thick OSB or plywood nailed with 8d (0.131" diameter x2.5") nails at 6" on center at all panel edges and at 12" on center intermediate.13.The floor is to be sheathed with 3/4" minimum thick OSB or plywood nailed with 8d (0.131" diameter x 3")nails at 6" on center at all panel edges and at 12" on center intermediate.14.Provide all general nailing and/or alternative screw/staple options as required per IRC tables R602.3(1),R602.3(2), and R702.3.5.15.Staples (minimum of 16 GA x 1.5" long) may be used in the plywood/OSB roof and wall sheathing at halfthe spacing noted.16.Block the roof truss heels at all shear wall panels per IRC figures R602.10.8.2(1), (2), and (3) and IRCfigures R602.10.8(1) and (2).
LOWER FLOOR PLANNOT TO SCALE1MAIN FLOOR PLANNOT TO SCALE2AWSP BRACE LINEREQUIRED LENGTH= 16'-6" < 21'-6" PROVIDED(NO HORIZ BLKG REQD)1BA2110'-9" PANEL10'-9" PANEL
WSP BRACE LINEREQUIRED LENGTH= 16'-6" < 25'-7" PROVIDED(NO HORIZ BLKG REQD)7'-6" PANEL
18'-1" PANEL
WSP BRACE LINEREQUIRED LENGTH= 17'-4" < 17'-8" PROVIDED(NO HORIZ BLKG REQD)9' PANEL8'-8" PANELCS-WSP BRACELINE, REQUIREDLENGTH = 7'-5"< 9'-2" PROVIDED2' CS-PF> 1'-6" MINCONT 3" x 11.25" MIN HEADER (ACTUAL SIZEFOR LOAD BY OTHERS) FOR CS-PF PORTALFRAME PANEL PER IRC R602.10.6.4 (COUNTSAT 1.5x LENGTH) W/ SIMPSON OR EQUALLSTA24 OR LARGER STRAPS FROM JACKSTUDS ACROSS HEADER TO TOP OF TOPPLATE AT EACH SIDE OF OPENING (SEE S4)2'-6" PANEL> 2'-3" MIN3'-8" PANEL> 3'-5" MINWSP BRACE LINEREQUIRED LENGTH= 8'-11" < 9'-10" PROVIDED4'-2" PANEL5'-8" PANELWSP BRACE LINEREQUIRED LENGTH= 12'-11" < 24'-6" PROVIDED24'-6" PANEL
Project Name:Lateral Brace Wall ReviewProject #:24-093Site Address:17774 Embers AveOswell Engineeringand Consulting, L.L.C.Page S2 of S4Lakeville, MNI hereby certify that this plan,specification, or report wasprepared by me or under mydirect supervision and that I ama duly licensed professionalengineer under the laws of thestate of Minnesota.Craig Oswell, PE (MN #42341) 7/31/20241901 E Hennepin Ave, #201Minneapolis, MN 55413Phone: 612-720-4639Fax: 612-886-2966www.oswellec.comPLANS(NOT TO SCALE)Client Name:Pinnacle Family HomesISSUED FOR CONSTRUCTION
Project Name:Lateral Brace Wall ReviewProject #:24-093Site Address:17774 Embers AveOswell Engineeringand Consulting, L.L.C.Page S3 of S4Lakeville, MNI hereby certify that this plan,specification, or report wasprepared by me or under mydirect supervision and that I ama duly licensed professionalengineer under the laws of thestate of Minnesota.Craig Oswell, PE (MN #42341) 7/31/20241901 E Hennepin Ave, #201Minneapolis, MN 55413Phone: 612-720-4639Fax: 612-886-2966www.oswellec.comMISC IRC DETAILS(NOT TO SCALE)Client Name:Pinnacle Family HomesISSUED FOR CONSTRUCTION
Project Name:Lateral Brace Wall ReviewProject #:24-093Site Address:17774 Embers AveOswell Engineeringand Consulting, L.L.C.Page S4 of S4Lakeville, MNI hereby certify that this plan,specification, or report wasprepared by me or under mydirect supervision and that I ama duly licensed professionalengineer under the laws of thestate of Minnesota.Craig Oswell, PE (MN #42341) 7/31/20241901 E Hennepin Ave, #201Minneapolis, MN 55413Phone: 612-720-4639Fax: 612-886-2966www.oswellec.comCS-PF PORTALFRAME DETAIL PERIRC 602.10.6.4(NOT TO SCALE)Client Name:Pinnacle Family HomesISSUED FOR CONSTRUCTION
TILELOADKITCHENISLANDABOVEBM1 (2) 9 1/2" LVL BM2 (4) 16" LVLFL06FL03FL02F01F02F02F02F02F02F02F02F02F02F02F03F04F03F05F03F06F07F08F08F08F08F09F09F09F09F09F09F09F10FL04FL05FL01F11F11F11F11F13F13F13F13F13F13F13F15F01F01F01F01F01F01F01F01F01F03F02F09F11F03.20-00-004-06-0031-06-0056-00-0026-00-008-00-00 8-00-00 5-00-00 9-00-0056-00-0020-00-0025-00-001-00-0046-00-0025-00-005-00-0016-00-0046-00-0011-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-06-041-03-115-001-02-031-03-053-141-03-021-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-031-07-0319401 Tamarack Street NWOak Grove, MN 55011PHONE: (612) 656-1642DIMENSIONINGNOTES:ALL DIMENSIONS ARE OR HAVE BEENADJUSTED TO SHEATHINGFLOORPinnacle Family Homes3949205JOB #:SCALE:DRAWNBY:DATE:7/15/2024ACNOT TO SCALE17774 Embers AveMNADDRESS:PROJECT:BUILDER:THESE PLANS ARE DESIGNED TO ASSIST IN THELOCATION AND ERECTION OF BUILDERS FIRSTSOURCETRUSSES ONLY. THEY ARE IN NO WAY TO BEREGARDED AS COMPLETE CONSTRUCTION DRAWINGS.THE BUILDER IS TOTALLY RESPONSIBLE FOR ERECTIONAND COMPLETION OF THE BUILDING, USINGSATISFACTORY CONSTRUCTION METHODS ANDTECHNIQUES AND FOR COMPLIANCE WITH ALL LOCAL,STATE AND FEDERAL CODES, ORDINANCES, ANDSTATUTES IN THAT REGARD.HANGER GENERAL NOTICE:REVISION DATESET CREW SHALL BE SOLELY RESPONSIBLE FOR CORRECTINSTALLATION OF ALL HANGERS. THIS SHALL INCLUDE, BUTNOT BE LIMITED TO, CORRECT NAIL SIZE, CORRECT NAILDIAMETER, CORRECT HANGER LOCATION, AND CORRECTHANGER SIZE AS NOTED ON THIS TRUSS LAYOUT. ALL NAILHOLES ARE TO BE FILLED PER HANGER SPECIFICATION.ANY DISCREPANCY BETWEEN HANGERS NOTED ON PLANAND HANGERS DELIVERED TO SITE SHALL BE REPORTEDPRIOR TO THE HANGERS INSTALLATION.GENERAL NOTICE:PAINTED END INDICATES THE TRIANGLE ENDSHOWN ON THE LAYOUTPAINTED END INDICATES THE TRIANGLE ENDSHOWN ON THE LAYOUTFLOORTRUSSESSUPPORTINGTILEFLOORINGMaximum truss spacing shall be 16" o.c. per ANSI A108/ANSI A118/136.Perpendicular blocking installed at 16" o.c. maximum shallbe permitted inlieu of the 16" o.c. truss spacing.FOR QUESTIONS REGARDINGTHIS LAYOUTPLEASE CONTACT:Andrew @ 612-656-1643
MUS28 (3)HHUS26-2 (1)HUS26 (5)..T03ET09T09T09T09T09T09T09T09T09T09T09T09T09M01ET04ET10T11T11T12T15T14T13T02ET07T07S07S07S07S07S07S07S07S06ES01ES01S01S01S04S05S06S06S06S06G02G01T05ET16T16T16J01J02J02T07S02S02S02V2AV2CV3AV3BV3CV3DV3EV3FV3GV2DV1AV1BV1CV4AV4BV4CV4DV4EV2B2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-002-00-002-00-002-00-002-00-002-00-001-10-121-01-041-00-002-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-002-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 2-00-00 1-10-127-042-00-00 2-00-00 1-11-04 2-00-00 2-00-00 2-00-002-00-002-00-0035-06-0026-00-0016-00-005-00-00 9-00-0062-00-0030-06-0024-06-001-00-0056-00-0010-00-0025-00-005-00-0016-00-0056-00-0026-06-0062-00-006-00-0019401 Tamarack Street NWOak Grove, MN 55011PHONE: (612) 656-1642DIMENSIONINGNOTES:ALL DIMENSIONS ARE OR HAVE BEENADJUSTED TO SHEATHINGROOFPinnacle Family Homes3949210JOB #:SCALE:DRAWNBY:DATE:7/15/2024ACNOT TO SCALE17774 Embers AveMNADDRESS:PROJECT:BUILDER:THESE PLANS ARE DESIGNED TO ASSIST IN THELOCATION AND ERECTION OF BUILDERS FIRSTSOURCETRUSSES ONLY. THEY ARE IN NO WAY TO BEREGARDED AS COMPLETE CONSTRUCTION DRAWINGS.THE BUILDER IS TOTALLY RESPONSIBLE FOR ERECTIONAND COMPLETION OF THE BUILDING, USINGSATISFACTORY CONSTRUCTION METHODS ANDTECHNIQUES AND FOR COMPLIANCE WITH ALL LOCAL,STATE AND FEDERAL CODES, ORDINANCES, ANDSTATUTES IN THAT REGARD.HANGER GENERAL NOTICE:REVISION DATESET CREW SHALL BE SOLELY RESPONSIBLE FOR CORRECTINSTALLATION OF ALL HANGERS. THIS SHALL INCLUDE, BUTNOT BE LIMITED TO, CORRECT NAIL SIZE, CORRECT NAILDIAMETER, CORRECT HANGER LOCATION, AND CORRECTHANGER SIZE AS NOTED ON THIS TRUSS LAYOUT. ALL NAILHOLES ARE TO BE FILLED PER HANGER SPECIFICATION.ANY DISCREPANCY BETWEEN HANGERS NOTED ON PLANAND HANGERS DELIVERED TO SITE SHALL BE REPORTEDPRIOR TO THE HANGERS INSTALLATION.GENERAL NOTICE:PAINTED END INDICATES THE TRIANGLE ENDSHOWN ON THE LAYOUTPAINTED END INDICATES THE TRIANGLE ENDSHOWN ON THE LAYOUTFOR QUESTIONS REGARDINGTHIS LAYOUTPLEASE CONTACT:Andrew @ 612-656-1643
TOTAL INPUT OF APPLIANCES1,
THOUSANDS OF Btu/hr
(kW)
REQUIRED FREE AREA OF AIR-SUPPLY
OPENING OR DUCT, SQUARE INCHES
(sq mm)
ACCEPTABLE APPROXIMATE ROUND DUCT
EQUIVALENT DIAMETER2,
INCH (mm)
25 (8)7 (4,500)3 (75)
50 (15)7 (4,500)3 (75)
75(23)11 (7,000)4 (100)
100 (30)14 (9,000)4 (100)
125 (37)18 (12,000)5 (125)
150 (45)22 (14,000)5 (125)
175 (53)25 (16,000)6 (150)
200 (60)29 (19,000)6 (150)
225 (68)32 (21,000)6 (150)
250 (75)36 (23,000)7 (175)
275 (83)40 (26,000)7 (175)
300 (90)43 (28,000)7 (175)
325 (98)47 (30,000)8 (200)
350 (105)50 (32,000)8 (200)
375 (113)54 (35,000)8 (200)
400 (120)58 (37,000)9 (225)
1. For total inputs falling between listed capacities, use next largest listed input.
2. If flexible duct is used, increase the duct diameter by one inch. *
*Flexible duct shall be stretched with minimal sags.
TABLE 304.1
COMBUSTION AIR REQUIREMENTS FOR GAS-FIRED
APPLIANCES WHEN THE COMBINED INPUT IS UP TO
AND INCLUDING 400,000 Btu/hr
BTU Amount for Non-direct vent appliances_____________________
1 2 3 4 5 6 2
Conditioned space1 (in sq. ft.)
Total/
Continuous
Total/
Continuous
Total/
Continuous
Total/
Continuous
Total/
Continuous
Total/
Continuous
1000-1500 60/40 75/40 90/45 105/53 120/60 135/68
1501-2000 70/40 85/43 100/50 115/58 130/65 145/73
2001-2500 80/40 95/48 110/55 125/63 140/70 155/78
2501-3000 90/45 105/53 120/60 135/68 150/75 165/83
3001-3500 100/50 115/58 130/65 145/73 160/80 175/88
3501-4000 110/55 125/63 140/70 155/78 170/85 185/93
4001-4500 120/60 135/68 150/75 165/83 180/90 195/98
4501-5000 130-65 145/73 160/80 175/88 190/95 205/103
5001-5500 140/70 155/78 170/85 185/93 200/100 215/108
5501-6000 2 150/75 165/83 180/90 195/98 210/105 225/113
1. Conditioned space includes the basement and conditioned crawl spaces.
2. If conditioned space exceeds 6000 sq. ft. or there are more than 6 bedrooms, use Equation R403.5.2
R403.5.2 Total Ventilation rate.
The mechanical ventilation system shall rovide sufficient outdoor air to equal the total ventilation rate average
for each 1- hour period in accordance with Table R403.5.2, or Equation 403.5.2, based on the number of bedrooms and
square footage of conditioned space, including the basement and conditioned crawl spaces.
For the purposes of Table R403.5.2 and Section R403.5.3, the following applies:
a. Equation R403.5.2 Total ventilation rate:
Total ventilation rate (cfm) = (0.02 x square feet of conditioned space) + (15 x (number of bedrooms +1))
b. Equation R403.5.2.1 Continuous ventilation rate: Continuous ventilation rate (cfm) = Total ventiation rate/2
Amount Total _________________________
Amount Continuous____________________
TABLE R403.5.2
NUMBER OF BEDROOMS
VENTILATION REQUIREMENTS
ONE OR MULTIPLE POWER VENT
OR DIRECT VENT APPLIANCES OR
NO COMBUSTION APPLIANCESA
ONE OR MULTIPLE FAN-
ASSISTED APPLIANCES AND
POWER VENT OR DIRECT
VENT APPLIANCESB
ONE ATMOSPHERICALLY
VENTED GAS OR OIL
APPLIANE OR ONE
SOLID FUEL APPLIANCEC
MULTIPLE APPLIANCES THAT
ARE ATMOSPHERICALLY
VENTED GAS OR OIL
APPLIANCES OR SOLID FUEL
APPLIANCESD
1. Use the Appropriate Column to Estimate House Infiltration
a) pressure factor
(cfm/sf)
b) conditioned floor
area (sf)
(including unfinished basements)
Estimated House
Infiltration (cfm):
[1a x 1b]
2. Exhaust Capacity
a) clothes dryer
b) 80% of largest
exhaust rating (cfm):
(not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust)
c) 80% of next largest
exhaust rating (cfm):not applicable
(not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust)
Total Exhaust Capacity
(cfm):
[2a+2b+2c]
3. Makeup Air Requirement
a) Total Exhaust
Capacity
(from above)
b) Estimated House
Infiltration (from
above)
Makeup Air
Quality (cfm):
[3a - 3b]
(if value is negative, no makeup air is needed
4. For Makeup Air Opening Sizing, refer to Table 501.4.2.
A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances.
B. Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included.
C. Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance.
D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically
vented gas or oil appliances and solid fuel appliances.
Table 501.4.1
Procedure to Determine Makeup Air Quantity for Exhaust Appliances in Dwelling Units
Choose Which Applies
TYPE OF OPENING
ONE OR MULTIPLE POWER
VENT OR DIRECT VENT
APPLIANCES OR NO
COMBUSTION
APPLIANCESA
ONE OR MULTIPLE FAN-
ASSISTED APPLIANCES
AND POWER VENT OR
DIRECT VENT APPLIANCESB
ONE
ATMOSPHERICALLY
VENTED GAS OR OIL
APPLIANCE OR ONE
SOLID FUEL
APPLIANCEC
MULTIPLE APPLIANCES
THAT ARE
ATMOSPHERICALLY
VENTED GAS OR OIL
APPLIANCES OR SOLID
FUEL APPLIANCESD
PASSIVE MAKEUP
AIR OPENING
DUCT
DIAMETERE,F,G
OR SYSTEM (cfm)(cfm)(cfm)(cfm)(inches)
Passive opening 1-36 1-22 1-15 1-9 3
Passive opening 37-66 23-41 16-28 10-17 4
Passive opening 67-109 42-66 29-46 18-28 5
Passive opening 110-163 67-100 47-69 29-42 6
Passive opening 164-232 101-143 70-99 43-61 7
Passive opening 233-317 144-195 100-135 62-83 8
Passive opening
with motorized
damper 318-419 196-258 136-179 84-110 9
Passive opening
with motorized
damper 420-539 259-332 180-230 111-142 10
Passive opening
with motorized
damper 540-679 333-419 231-290 143-179 11
Powered makeup
airH >679 >419 >290 >179 Not applicable
A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances.
B. Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included.
C. Use this column if there is one atmospherically vented (ther than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance.
D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented
gas or oil appliances and solid fuel appliances.
E. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90-degree
elbow to determine the remaining length of straight duct allowable.
F. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags.
G. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed.
H. Powered makeup air shall be electrically interlocked with the largest exhaust system.
Table 501.4.2
Makeup Air Opening Sizing Table for New and Existing Dwelling Units
IFGC Appendix E, Worksheet E-1
Residential Combustion Air Calculation Method
(for Furnace, Boiler, and/or Water Heater in the Same Space)
Step 1: Complete vented combution appliace information:
Furnace/Boiler:
Draft Hood Fan Assisted Direct Vent Input: Btu/hr
(Not fan Assisted) & Power Vent
Water Heater:
Draft Hood Fan Assisted Direct Vent Input: Btu/hr
( Not fan Assisted) & Power Vent
Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances.
The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft3
Step 3: Determine air Changes per Hour (ACH)1
Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction
or ACH is not known, use method 4a (Standard Method).
Step 4: Determine Required Volume for Combustion Air.
4a. Standard Method
Total Btu/hr input of all combustion appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Input: Btu/hr
Use Standard Method column in Table E-1 to find Total Required Volume (TRV) TRV: ft3
If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed.
If CAS Volume (from Step 2) is less than TRV then go to STEP 5.
4b. Known Air Infiltration Rate (KAIR) Method
Total Btu/hr input of all fan-assisted and power vent appliances
(DO NOT COUNT DIRECT VENT APPLIANCES) Input: Btu/hr
Use Fan-Assisted Appliances column in Table E-1 to find
Required Volume Fan Assisted (RVFA) RVFA: ft3
Total Btu/hr input of all non-fan-assisted appliances Input: Btu/hr
Use Non-Fan-Assisted Appliances column in Table E-1 to find
Required Volume Non-Fan-Assisted (RVNFA) RVNFA: ft3
Total Required Volume (TRV) = RVFA + RVNFA TRV = + = ft3
If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed.
If CAS Volume (from Step 2) is less than TRV then go to STEP 5.
Step 5: Calculate the ratio of available interior volume to the total required volume.
Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio =
Step 6: Calculate Reduction Factor (RF).
RF = 1 minus Ratio RF = - =
Step 7: Calculate single outdoor opening as if all combustion air is from outside.
Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Input: Btu/hr
Combustion Air Opening Area (CAOA):
Total Btu/hr divided by 3000 Btu/hr per in2 / Btu/hr per in
2 = in2
Step 8: Calculate Minimum CAOA.
Minimum CAOA = CAOA multiplied by RF Minimum CAOA = x = in2
Step 9: Calculate Combustion Air Opening Diameter (CAOD)
CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 x Minimum CAOA = in
1If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section 304.
CAOA =
IFGC Appendix E, Table E-1
Residential Combustion Air Required Volume (Required Interior Volume Based on Input Rating of Appliances)
Known Air Infiltration Rate (KAIR) Method (ft3)
Input Rating Standard Method Fan Assisted Non-Fan-Assisted
(Btu/hr) (ft3) 19941 to Present Pre 19942 19941 to Present Pre 19942
5,000 250 375 188 525 263
10,000 500 750 375 1,050 525
15,000 750 1,125 563 1,575 788
20,000 1,000 1,500 750 2,100 1,050
25,000 1,250 1,875 938 2,625 1,313
30,000 1,500 2,250 1,125 3,150 1,575
35,000 1,750 2,625 1,313 3,675 1,838
40,000 2,000 3,000 1,500 4,200 2,100
45,000 2,250 3,375 1,688 4,725 2,363
50,000 2,500 3,750 1,875 5,250 2,625
55,000 2,750 4,125 2,063 5,775 2,888
60,000 3,000 4,500 2,250 6,300 3,150
65,000 3,250 4,875 2,438 6,825 3,413
70,000 3,500 5,250 2,625 7,350 3,675
75,000 3,750 5,625 2,813 7,875 3,938
80,000 4,000 6,000 3,000 8,400 4,200
85,000 4,250 6,375 3,188 8,925 4,463
90,000 4,500 6,750 3,375 9,450 4,725
95,000 4,750 7,125 3,563 9,975 4,988
100,000 5,000 7,500 3,750 10,500 5,250
105,000 5,250 7,875 3,938 11,025 5,513
110,000 5,500 8,250 4,125 11,550 5,775
115,000 5,750 8,625 4,313 12,075 6,038
120,000 6,000 9,000 4,500 12,600 6,300
125,000 6,250 9,375 4,688 13,125 6,563
130,000 6,500 9,750 4,875 13,650 6,825
135,000 6,750 10,125 5,063 14,175 7,088
140,000 7,000 10,500 5,250 14,700 7,350
145,000 7,250 10,875 5,438 15,225 7,613
150,000 7,500 11,250 5,625 15,750 7,875
155,000 7,750 11,625 5,813 16,275 8,138
160,000 8,000 12,000 6,000 16,800 8,400
165,000 8,250 12,375 6,188 17,325 8,663
170,000 8,500 12,750 6,375 17,850 8,925
175,000 8,750 13,125 6,563 18,375 9,188
180,000 9,000 13,500 6,750 18,900 9,450
185,000 9,250 13,875 6,938 19,425 9,713
190,000 9,500 14,250 7,125 19,950 9,975
195,000 9,750 14,625 7,313 20,475 10,238
200,000 10,000 15,000 7,500 21,000 10,500
205,000 10,250 15,375 7,688 21,525 10,763
210,000 10,500 15,750 7,875 22,050 11,025
215,000 10,750 16,125 8,063 22,575 11,288
220,000 11,000 16,500 8,250 23,100 11,550
225,000 11,250 16,857 8,438 23,625 11,813
230,000 11,500 17,250 8,625 24,150 12,075
1The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is 0.20 ACH.
2This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH.
Bold/italic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2024-Jul-11 12:44:25Right-Suite® Universal 2024 24.0.02 RSU59223 Page 1...eat Loss Folder\Pinnacle Homes 17774 Embers.rup Calc = MJ8 Front Door faces: N
Jawahir ResidenceJob:Project Summary 2024Date:Entire House Shawn LynchBy:
Custom RamblerPlan:Elander Mechanical Inc.
645 Shenandoah Drive, Shakopee, MN 55379 Phone: 952-445-4692 Email: elandermechanical@elandermechanical.com Web: elandermechanical.com
Project Information
Pinnacle Family HomesFor:
Notes:
Design Information
Minneapolis-St Paul Int'l Arp, MN, USWeather:
Winter Design Conditions Summer Design Conditions
Outside db °F-15 Outside db °F88Inside db °F70 Inside db °F75Design TD °F85 Design TD °F13Daily range MRelative humidity %50Ventilation Method ASHRAE 62.2-2019 Moisture difference gr/lb31
Heating Summary Sensible Cooling Equipment Load Sizing
Structure Btuh39527 Structure Btuh25135DuctsBtuh0DuctsBtuh0Central vent (SER=50% 161 cfm)Btuh7297 Central vent (SER=50% 161 cfm)Btuh1107Heat recovery Heat recoveryHumidificationBtuh0Blower Btuh1707PipingBtuh0Equipment load Btuh46824 Use manufacturer's data nRate/swing multiplier 0.93InfiltrationEquipment sensible load Btuh25964
Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Semi-tight0Fireplaces Structure Btuh2131DuctsBtuh0Central vent (161 cfm)Btuh3321CoolingHeatingHeat recovery36133613Area (ft²)Equipment latent load Btuh54522124921249Volume (ft³)Air changes/hour 0.100.19 Equipment Total Load (Sen+Lat)Btuh31416Equiv. AVF (cfm)3567 Req. total capacity at 0.80 SHR ton2.7
Heating Equipment Summary Cooling Equipment Summary
Make Lennox Make LennoxTradeLENNOXTradeLENNOXModelML193UH070XE36B-*Cond ML14XC1S036-230C**AHRI ref 202568879 Coil CK40CT-36B-0*++TDRAHRI ref 214629100Efficiency93 AFUE Efficiency 11.2 EER2,13.4 SEER2Heating input Btuh66000 Sensible cooling Btuh27200Heating output Btuh63000 Latent cooling Btuh6800Temperature rise °F50 Total cooling Btuh34000Actual air flow cfm1181 Actual air flow cfm1133Air flow factor cfm/Btuh0.030 Air flow factor cfm/Btuh0.045Static pressure in H2O0 Static pressure in H2O0.80Space thermostat Load sensible heat ratio 0.84
Date Certificate Posted
X Passive (No Fan)
Active (With fan and monometer or other
system monitoring device )
Location (or future location) of Fan:
Other Please Describe Here
X
R-15 X
X
R-20 X
R-20 X
R-20 X
R-49 X
R-49 X
R-30 X
R-30 X
Not applicable, all ducts located in conditioned space
R-8
X Not required per mech. code
Passive
Powered
Interlocked with exhaust device.
Describe:
Input in
BTUS:66,000 Capacity in
Gallons:Other, describe:
AFUE or
HSPF%
93%
Cfm's
" round duct OR
" metal duct
Not required per mech. code
X Passive
X Low: Other, describe:
Low:
Location of fan(s), describe: Cfm's
6 " round duct OR
" metal duct
Duct system air tightness:
Heating or Cooling Ducts Outside Conditioned Spaces
Ceiling, vaulted
Bay Windows or cantilevered areas
Floors over unconditioned area
Describe other insulated areas
Building envelope air tightness:
Windows & Doors
Average U-Factor (excludes skylights and one door) U: 0.30
Solar Heat Gain Coefficient (SHGC): 0.30 R-value
MECHANICAL SYSTEMS Make-up Air Select a Type
Appliances Heating System
Domestic Water
Heater Cooling System
Nat Gas Nat Gas Elect
GPVL-50 ML14XC1S036
Fuel Type
Manufacturer Lennox AOSmith Lennox
Model ML193UH070XE36B
14 Location of duct or system:
Rating or Size
50 Output in
Tons:3
Efficiency
SEER
/EER
Residential Load Calculation
Heating Loss Heating Gain Cooling Load Mech room
46,824 25,964 31,416
MECHANICAL VENTILATION SYSTEM
Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air
source heat pump with gas back-up furnace):
Combustion Air Select a Type
Select Type
Heat Recover Ventilator (HRV) Capacity in cfms: 180
MN License Number
Pinnacle Family Homes
THERMAL ENVELOPE RADON CONTROL SYSTEM
Type: Check All That Apply
Insulation Location
Total R-Value of all Types of InsulationNon or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateNew Construction Energy Code Compliance Certificate
Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution
panel.
Mailing Address of the Dwelling or Dwelling Unit City
Lakeville17774 Embers Ave.
Name of Residential Contractor
Below Entire Slab
Foundation Wall
Perimeter of Slab on Grade
Rim Joist (1st Floor)
Rim Joist (2nd Floor+)
Wall
Ceiling, flat
Interior R5 + R10 Exterior
Interior
Interior
Balanced Ventilation capacity in cfms:Mech Room
Capacity continuous ventilation rate in cfms:
Total ventilation (intermittent + continuous) rate in cfms:
50 High:
Energy Recover Ventilator (ERV) Capacity in cfms: High:
Location of duct or system: