Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA226566-18356 Glacier Way-Permit Pack
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -6 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"GARAGE PLATE HEIGHT10' - 9 3/8"VINYL BOARD& BATTEN TYP.CULTURED STONEW/ CONCRETE CAPALUMINUM SOFFIT& FASCIA TYP.3' - 6"SEE COLUMN DETAILSHEET A-5016" SMARTSIDE FRIEZE BOARD TYP.VINYL LAPSIDING TYP. @ FRONT4" SMARTSIDE TRIM@ WINDOWS & DOORS AT FRONTADDRESS STONE1' - 0"8" 12"7" / 12"7" / 12"8:128" 12"8:12PLUMBING NOTESTOTAL FIXTURE UNITS: 59TOTAL LENGTH: 95'WATER SERVICE SIZE: 1"WATER METER SIZE: 1"WATER HEATER FEED: 1"BUILDING SUPPLY TO 1st BRANCH: 1 1/4"SOFTENER INLET SIZE: 1 1/4"WATER PRESSURE AT THE STREET: 60 PSIDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 6REV. 7REV. 8REV. 9REV. 10PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN8/15/2024 3:53:50 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18356 GLACIER WAYLAKEVILLE, MN 55044A-201OTT4568.14.24 CB1682149511838.15.24 DB5.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNA1/4" = 1'-0"A-2011FRONT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONA-202 ELEVATIONS/ ROOF PLANA-401 FOUNDATION PLANA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 SCHEDULES/ DETAILSA-502 DETAILSConcept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode08/16/2024jnuetzman 24" RETURN TYP.8" / 12"8" / 12"8" / 12"7" 12"4" / 12"8" / 12"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING &CORNERS TYP.8" 12"8" 12"4" 12"4" / 12"24" RETURN TYP.8" / 12"8" / 12"8" / 12"4" 12"STANDARD ENERGY HEELS @ 8:1218" OVERHANGS & 12" RAKES TYP.7 ROOF VENT REQUIRED STANDARD ENERGY HEELS @ 4:12 W/ 7:12 & 8:12 FASCIA LINES TO MATCH3 ROOF VENTS REQUIRED 1 ROOF VENT REQUIRED 8" / 12"8" / 12"8" / 12"7" / 12"8" / 12"8" / 12"7" / 12"4" / 12"8" / 12"8" / 12"4" / 12"8" / 12"DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 6REV. 7REV. 8REV. 9REV. 10PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN8/15/2024 3:53:53 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18356 GLACIER WAYLAKEVILLE, MN 55044A-202OTT4568.14.24 CB1682149511838.15.24 DB5.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNA1/8" = 1'-0"A-2021RIGHT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023LEFT ELEVATION1/8" = 1'-0"A-2024ROOF PLANSecure door closed until deck isconstructed with a separate permit. 9' - 10"18' - 6"30' - 6"0' - 2"20' - 6"10' - 0"1' - 4 1/2"8' - 3" M.O.0' - 4 1/2"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"*ALL DIMENSIONS ARETO EXTERIOR OFCONCRETE, NOT 2" FOAM INSULATIONBETWEEN WALL & SLAB8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.49' - 0"29' - 8"21' - 8"30' - 4"6' - 0"5' - 10"11' - 10"40' - 2"52' - 0"0' - 4"52' - 0"54 x 54" x 12" CONCRETE FTG.W/ (6) #5 REBAR EACH WAY19' - 4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY8' - 3 1/4"14' - 9"4' - 2 3/4"4' - 2 3/4"8' - 8 1/4"8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.9' - 9 1/4"11' - 10 3/4"9' - 1 1/4"10' - 2 3/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY4' - 2 3/4"26' - 10 1/4"17' - 11"11' - 6"10' - 10"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY4' - 2 3/4"25' - 5 1/4"13' - 9 1/4"3' - 2 3/4"17' - 6"14' - 6"17' - 0"49' - 0"2' - 0"6' - 0"22' - 4"19' - 8"2' - 0":LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAYANCHOR BOLTS TO EACH SIDE OF BEARING POINT TYPICAL42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY5' - 10 3/4"8' - 1 3/4"5' - 3 1/2"4' - 4 1/2"3' - 3" M.O.12' - 0 1/2"48" x 48" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAYDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 6REV. 7REV. 8REV. 9REV. 10PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN8/15/2024 3:53:53 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18356 GLACIER WAYLAKEVILLE, MN 55044A-401OTT4568.14.24 CB1682149511838.15.24 DB5.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNA1/4" = 1'-0"A-4011FOUNDATION PLANUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. UNEXCAVATEDMECHANICAL/ STORAGE9' - 10"11' - 10"20' - 6"10' - 0"0' - 2"18' - 6"30' - 6"40' - 2"5' - 10"6' - 0"12' - 11"27' - 3"8' - 11"4' - 0"4' - 0"23' - 3"UNEXCAVATED9' - 0"8' - 0"7' - 6"7' - 0"8' - 9"8' - 9"52' - 0"SET SILL 6" ABOVE TREATED PLATE 0' - 4"*ALL DIMENSIONS ARE TOEXTERIOR OF CONCRETE ORSHEATHING, NOT 2" FOAM INSULATIONBETWEEN WALL & SLAB0' - 4"49' - 0"5' - 0 1/2"8' - 1"4' - 2 3/4"BEDROOM #4FAMILY ROOMSUMPR & SH.48" F.G. SHWR5' VANITYBATH #52x6FURNACEAIR EX.6' - 0"5' - 10"37' - 2"40' - 2"11' - 10"21' - 8"30' - 4"52' - 0"19' - 4"CO DET.SMOKEDET.2-2x103-9 1/2" LSL W/2 TRIMMERS 5x5 PSL2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"0' - 4 1/2"8' - 3" M.O.1' - 4 1/2"SMOKEDET.W. H.2-2x105' - 10"6' - 0"7' - 6"2' - 6"9' - 4"6' - 7"4' - 3"11' - 6"72/8 x 6/8R.O. 2' -10" x 6' -11"18" FLOOR TRUSSESPER MFG. SPACING62/6 x 6/8R.O. 2' -8" x 6' -11"29' - 8"6036E NVG114R.O. 6' -0" x 3' -6"H.H. 6' -10"4030 NVPWG TEMP.10R.O. 4' -0" x 3' -0"H.H. 11' -8"FROM LOWER FLOOR17' - 6"14' - 6"17' - 0"49' - 0"MECHANICAL CHASE ABOVE 2' - 0"6' - 0"22' - 4"19' - 8"2' - 0"ANCHOR BOLTS TO EACH SIDE OF BEARING POINT TYPICAL123/0 x 6/8R.O. 3' -2" x 6' -11"2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.32/4 x 6/8R.O. 2' -6" x 6' -11"14' - 3"FLEX ROOM18" FLOOR TRUSSESPER MFG. SPACING6036E NVG114R.O. 6' -0" x 3' -6"H.H. 6' -10"6036E NVG114R.O. 6' -0" x 3' -6"H.H. 6' -10"W.S.4' - 4 1/2"3' - 3" M.O.12' - 0 1/2"2x632/4 x 6/8R.O. 2' -6" x 6' -11"72/8 x 6/8R.O. 2' -10" x 6' -11"6' - 6"3-14" LSL FLUSH5x5 PSL5x5 PSL2-2x102-9 1/2" LSL 3-2x63' - 2"4' - 0"DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 6REV. 7REV. 8REV. 9REV. 10PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN8/15/2024 3:53:54 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18356 GLACIER WAYLAKEVILLE, MN 55044A-402OTT4568.14.24 CB1682149511838.15.24 DB5.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNA1/4" = 1'-0"A-4021LOWER FLOOR PLAN-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).FAN 40' - 0"12' - 0"36" REFSINKDWPORCH20' - 6"10' - 0"2' - 3"16' - 0"2' - 3"0' - 6"8' - 0"1' - 6"52' - 0"17' - 6"14' - 6"17' - 0"GARAGE30' - 0"4' - 0"4' - 6"7' - 8"5' - 0"22' - 0"30' - 0"52' - 0"FOYERGREAT ROOMDININGEQEQ10' - 0"RAILING KNEE WALL W/14" PAINTED SPINDELS 8' - 0"15' - 3"4' - 0"4' - 0"8' - 9"6' - 0"5' - 10"0' - 10"36' - 4"SEE COLUMN DETAILSHEET A-501ATTICACCESS2' - 0"6' - 0"22' - 0"20' - 0"2' - 0"18' - 6"30' - 6"6' - 0"6' - 0"5' - 3"8' - 6"5' - 3"7' - 4 1/4"1' - 3"1' - 3"9' - 1 3/4"4' - 11"3' - 10"MECH CHASE17' - 6"12' - 6"DBL. FRAMED WALLFOR REFG. RECESSOVEN /MICRO3' - 3"3' - 6"3' - 9"4' - 9"6' - 9"2' - 6"5' - 0"4' - 9 1/4"4' - 2 3/4"16" SH.12" SH.PANTRYBATH #4FLEX ROOM9' - 0"4' - 7"36" GASCOOKTOPW/ WOOD HOOD ABOVE10" FLUSH S.B.6' - 0"14' - 0"8' - 7 1/4"13' - 4 3/4"8' - 9"8' - 9"7' - 0"7' - 6"10' - 6"6' - 6"0' - 5"9' - 4"8' - 0"0' - 9"FLOOR GIRDERKITCHENSTUDYR & SH.3-TRIMMERS 3-11 7/8" LSL FLUSH5x5 PSLGIRDER TRUSSGIRDER TRUSS3-TRIMMERS 3-11 7/8" LVL2-11 7/8" LSL4-2x62-2x102-2x102-2x102-2x10FLUSH2-9 1/2" LVLFLUSHR-38 INSULATION INFLOOR ABOVE SMOKEDET.2-2x106'-10" ABOVE LANDINGRECYCLE7' - 2"2' - 6"9' - 4"MUD RM.19' - 0"3-14" LSL FLUSH49' - 0"14' - 6"11' - 4"END PANEL39"x73" FRIG RECESS2' - 9"4' - 0"3-9 1/2" LSLSTAGGERED UPPERS20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING82/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"42/4 x 6/8 FULL VIEWR.O. 2' -6" x 6' -11"72/8 x 6/8R.O. 2' -10" x 6' -11"113/0 x 6/8 W/ 12" D.S. SL'SSTEEL32/4 x 6/8R.O. 2' -6" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"1616' x 8' O.H. GARAGE DOORINSULATED158' x 8' O.H. GARAGE DOORINSULATEDMFG. ROOF TRUSSES@ 24" O.C.2-2x10 W/2 TRIMMERS MFG. ROOF TRUSSES@ 24" O.C.-SET FIREPLACE 12" A.F.F.20" FLOOR TRUSSESPER MFG. SPACING2' - 0"12' - 9"22' - 11 3/4"4' - 3 1/4"3060E NVH28R.O. 6' -0" x 6' -0"H.H. 8' -0"4040 NVPWG TEMP.11R.O. 4' -0" x 4' -0"H.H. 12' -6 3/4"FROM MAIN FLOOR49' - 0"U.C. LIGHTS U.C.LIGHTS U.C. LIGHTS U.C.LIGHTS 32/4 x 6/8R.O. 2' -6" x 6' -11"R & SH.2020 NVPWG2R.O. 2' -0" x 2' -0"H.H. 8' -0"20" FLOOR TRUSSESPER MFG. SPACING0' - 5"5' - 7"5' - 0"2-2x10136/0 x 6/8 FULL VIEW W/ GRIDSR.O. 6' -2" x 6' -11"103/0 x 6/8 FULL VIEW FIXED W/GRIDSR.O. 3' -2" x 6' -11"1032/4 x 6/8R.O. 2' -6" x 6' -11"52/4 x 6/8 PKTR.O. 4' -10" x 6' -11"12/0 x 6/8R.O. 2' -2" x 6' -11"3-2x10 DROPPED CONT. 2-2x10 FLUSH2-2x10 FLUSH2-2x10 FLUSH2640 NVH14R.O. 2' -6" x 4' -0"H.H. 6' -10"60" F.G. SHWR3'-6" VANITY3060E NVH16R.O. 3' -0" x 6' -0"H.H. 8' -0"6146/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"COMFORT HEIGHT 93/0 x 6/8R.O. 3' -2" x 6' -10 1/4"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. CEILING1/2" GYP. BD. ON GARAGE WALLSGARAGE PLATE HEIGHT TOMATCH MAIN FLOOR UNLESS NOTED OTHERWISE48" WIDE CONCRETE SIDEWALK TO DRIVEWAY INSULATE GARAGE WALLS AND CEILING 3060E NVH1-3660 NVPWH-3060E NVH17R.O. 9' -6" x 6' -0"H.H. 8' -0"MFG. ROOF TRUSSES@ 24" O.C.SUNROOM2' - 6"3' - 6"2050 NVH23R.O. 4' -0" x 5' -0"H.H. 6' -10"0' - 3" TYP.0' - 3"36" GAS F.P.5x5 PSL 5x5 PSL3-2x63-2x6DO NOT LET PORCH BEAM IN GARAGE WALLLUS210-2MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.2-2x102-2x103-2x102-2x10GIRDER TRUSSSMOKEDET.CO DET.3-2x6GIRDER TRUSS1/4" = 1'-0"A-4031MAIN FLOOR PLANDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 6REV. 7REV. 8REV. 9REV. 10PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN8/15/2024 3:53:56 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18356 GLACIER WAYLAKEVILLE, MN 55044A-403OTT4568.14.24 CB1682149511838.15.24 DB5.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNA-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).FANVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.BWPsAboveBWPsAboveBWPsAbove7.53.55Top of WallConnectionsPFHPFH6616.411.47.1BWPsAbove 17' - 0"15' - 0"13' - 0"2' - 0"34' - 0"6' - 0"6' - 0"5' - 10"33' - 2"CO DET.SMOKEDET.SMOKEDET.38' - 0"6' - 0"PRIMARY SUITEBOX VAULTBEDROOM #2EN SUITE #2HALLBEDROOM #35' - 8 3/4"7' - 2"6' - 11 1/4"14' - 2"14' - 9"4' - 0"4' - 0"15' - 3"17' - 4 1/4"4' - 1 1/2"6' - 5"3' - 9"13' - 4 1/4"12' - 0"7' - 0"26' - 0"8' - 6"8' - 6"7' - 6"7' - 6"6' - 6"6' - 6"18' - 9"19' - 3"6' - 0"6' - 0"3' - 6"3' - 6"23' - 10"10' - 2"12' - 2"6' - 5 3/4"13' - 0"7' - 8 1/2"5' - 7 3/4"2-2x102-9 1/2" LSLKNEE WALLW/ 14" PAINTED SPINDLES MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.ATTICACCESS10'-10" ABOVE LANDING45' - 0"7' - 8"3' - 8"1' - 10"7' - 11 1/4"5' - 1 3/4"PRIMARYBATHLAUNDRYMFG. ROOF TRUSSES@ 24" O.C.PRIMARYCLOSETEN SUITE #345' - 0"2-2x102-2x1044' - 0"42' - 0"5' - 11"7' - 10"SMOKEDET.2020 NVA11R.O. 2' -0" x 2' -0"H.H. 6' -10"4030 NVPWG TEMP.10R.O. 4' -0" x 3' -0"H.H. 6' -10"6020 NVFA313R.O. 6' -0" x 2' -0"H.H. 5' -8 7/8"FROM UPPER FLOOR8050E NVGE15R.O. 8' -0" x 5' -0"H.H. 6' -10"72/8 x 6/8R.O. 2' -10" x 6' -11"12' - 2"HALF WALL 5040E NVG112R.O. 5' -0" x 4' -0"H.H. 6' -10"13' - 9"62/6 x 6/8R.O. 2' -8" x 6' -11"62/6 x 6/8R.O. 2' -8" x 6' -11"R & SH.6' VANITY22/4 SHWR DR.3' x 5' TUB W/ TILEDECK32/4 x 6/8R.O. 2' -6" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"2' LINEN2' - 4"18' - 11"4' - 9"3040E NVC15R.O. 3' -0" x 4' -0"H.H. 6' -10"2020 NVA11R.O. 2' -0" x 2' -0"H.H. 6' -10"5040E NVG112R.O. 5' -0" x 4' -0"H.H. 6' -10"TYP.2' - 0"2' LINEN4' VANITY5' TUB/SHWR5' TUB/SHWR4' VANITYSMOKEDET.LOFTR & SH.R & SH.R & SH.R & SH.CLOSET #2CLOSET #33636 NVG19R.O. 3' -6" x 3' -6"H.H. 6' -10"2x6MFG. ROOF TRUSSES@ 24" O.C.WASHERDRYERSINK3' - 7"72/8 x 6/8R.O. 2' -10" x 6' -11"62/6 x 6/8R.O. 2' -8" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"2' - 0"5' - 11"3' - 5"TILE SHOWER4' - 5 3/4"6' - 5"4' - 1 1/4"42" HALF WALL W/ GLASS PANEL ABOVE 2-2x102-2x102-2x102-2x102-2x101' - 11"14' - 2"DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 6REV. 7REV. 8REV. 9REV. 10PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN8/15/2024 3:53:57 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18356 GLACIER WAYLAKEVILLE, MN 55044A-404OTT4568.14.24 CB1682149511838.15.24 DB5.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNA1/4" = 1'-0"A-4041UPPER FLOOR PLANFANFANFANFANTemper ifwithin 60"of tub floorTemper ifwithin 60"of tub floorTemper ifwithin 60"of tub floor-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).3.753.5 1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 6REV. 7REV. 8REV. 9REV. 10PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN8/15/2024 3:53:57 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18356 GLACIER WAYLAKEVILLE, MN 55044A-501OTT4568.14.24 CB1682149511838.15.24 DB5.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNAWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 VECTOR ENVISION SERIES 2 2020 NVA1 2' - 0" 2' - 0" 6' - 10"2 VECTOR ENVISION SERIES 1 2020 NVPWG 2' - 0" 2' - 0" 8' - 0"3 VECTOR ENVISION SERIES 1 2050 NVH2 4' - 0" 5' - 0" 6' - 10"4 VECTOR ENVISION SERIES 1 2640 NVH1 2' - 6" 4' - 0" 6' - 10"5 VECTOR ENVISION SERIES 1 3040E NVC1 3' - 0" 4' - 0" 6' - 10"6 VECTOR ENVISION SERIES 2 3060E NVH1 3' - 0" 6' - 0" 8' - 0"7 VECTOR ENVISION SERIES 1 3060E NVH1-3660 NVPWH-3060E NVH1 9' - 6" 6' - 0" 8' - 0"8 VECTOR ENVISION SERIES 1 3060E NVH2 6' - 0" 6' - 0" 8' - 0"9 VECTOR ENVISION SERIES 1 3636 NVG1 3' - 6" 3' - 6" 6' - 10"10 VECTOR ENVISION SERIES 2 4030 NVPWG TEMP. 4' - 0" 3' - 0" VARIES11 VECTOR ENVISION SERIES 1 4040 NVPWG TEMP. 4' - 0" 4' - 0" 12' - 6 3/4"12 VECTOR ENVISION SERIES 2 5040E NVG1 5' - 0" 4' - 0" 6' - 10"13 VECTOR ENVISION SERIES 1 6020 NVFA3 6' - 0" 2' - 0" 5' - 8 7/8"14 VECTOR ENVISION SERIES 3 6036E NVG1 6' - 0" 3' - 6" 6' - 10"15 VECTOR ENVISION SERIES 1 8050E NVGE 8' - 0" 5' - 0" 6' - 10"ROOM FINISH SCHEDULEFLOOR NAME FLOOR FINISH AREA PLATE HEIGHT COMMENTSLOWER FLOOR MECHANICAL / STORAGE CONCRETE 138 SF 8' - 2"LOWER FLOOR BEDROOM #4 CARPET 227 SF 8' - 2" .LOWER FLOOR FAMILY ROOM CARPET 439 SF 8' - 2" .LOWER FLOOR BATH #5 VINYL 53 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 84 SF 8' - 2"LOWER FLOOR FLEX ROOM 346 SF 8' - 2"MAIN FLOOR PORCH CONCRETE 111 SF 9' - 1 1/8"MAIN FLOOR GARAGE CONCRETE 614 SF 10' - 9 3/8"MAIN FLOOR FOYER WOOD 80 SF 9' - 1 1/8" .MAIN FLOOR GREAT ROOM WOOD 252 SF 9' - 1 1/8" .MAIN FLOOR DINING WOOD 159 SF 9' - 1 1/8" .MAIN FLOOR PANTRY VINYL 24 SF 9' - 1 1/8" .MAIN FLOOR BATH #4 VINYL 72 SF 9' - 1 1/8" .MAIN FLOOR FLEX ROOM CARPET 144 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 281 SF 9' - 1 1/8" .MAIN FLOOR STUDY CARPET 56 SF 9' - 1 1/8" .MAIN FLOOR MUD RM. VINYL 33 SF 9' - 1 1/8" .MAIN FLOOR STAIRWAY CARPET 94 SF 9' - 1 1/8"MAIN FLOOR SUNROOM 124 SF 9' - 1 1/8"UPPER FLOOR PRIMARY SUITE CARPET 242 SF 8' - 1 1/8" BOX VAULTUPPER FLOOR BEDROOM #2 CARPET 171 SF 8' - 1 1/8" .UPPER FLOOR EN SUITE #2 VINYL 59 SF 8' - 1 1/8" .UPPER FLOOR HALL CARPET 134 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 189 SF 8' - 1 1/8" .UPPER FLOOR PRIMARY BATH TILE 130 SF 8' - 1 1/8"UPPER FLOOR LAUNDRY VINYL 53 SF 8' - 1 1/8"UPPER FLOOR PRIMARY CLOSET CARPET 110 SF 8' - 1 1/8"UPPER FLOOR EN SUITE #3 CARPET 59 SF 8' - 1 1/8"UPPER FLOOR LOFT 168 SF 8' - 1 1/8"UPPER FLOOR CLOSET #2 50 SF 8' - 1 1/8"UPPER FLOOR CLOSET #3 48 SF 8' - 1 1/8"DOOR SCHEDULETYPE MARK DOOR SIZES ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 2/0 x 6/8 2' - 2" 6' - 11" 12 2/4 SHWR DR. 13 2/4 x 6/8 2' - 6" 6' - 11" 124 2/4 x 6/8 FULL VIEW 2' - 6" 6' - 11" 1 FROSETED GLASS5 2/4 x 6/8 PKT 4' - 10" 6' - 11" 16 2/6 x 6/8 2' - 8" 6' - 11" 57 2/8 x 6/8 2' - 10" 6' - 11" 48 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 19 3/0 x 6/8 3' - 2" 6' - 10 1/4" 110 3/0 x 6/8 FULL VIEW FIXED W/ GRIDS 3' - 2" 6' - 11"211 3/0 x 6/8 W/ 12" D.S. SL'S STEEL 112 3/0 x 6/8 3' - 2" 6' - 11" 113 6/0 x 6/8 FULL VIEW W/ GRIDS 6' - 2" 6' - 11" 114 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 115 8' x 8' O.H. GARAGE DOOR INSULATED 116 16' x 8' O.H. GARAGE DOOR INSULATED 11/2" = 1'-0"A-5012TYPICAL COLUMN3" MIN. ABS OR PVC GASTIGHT PIPE FROM SUBSLAB TO MIN.12" ABOVE ROOF, MUST BE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TO SUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY) IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0" AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESS THAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BE MIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING IN ADJOINING OR ADJACENT BUILDINGS.SUFFICIENT SPACE MUST BE LEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BE MIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALL SOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELS OF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHER BARRIERS IF AIRFLOW HAS BEEN ESTABLISHED.LABEL THE VENT PIPE AT LEAST ONCE PER FLOOR AND IN ACCESSIBLE ATTICSWITH "RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE IS REQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM: WATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANS2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSSDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 6REV. 7REV. 8REV. 9REV. 10PLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREIN WERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECKALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN8/15/2024 3:53:58 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18356 GLACIER WAYLAKEVILLE, MN 55044A-502OTT4568.14.24 CB1682149511838.15.24 DB5.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNA3/8" = 1'-0"A-5021TYP. WALL SECTION1/2" = 1'-0"A-5022TYP. WALKOUT SECTION1/2" = 1'-0"A-5023TYP. LOOKOUT SECTION1/2" = 1'-0"A-5024TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5025TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5026BEARING WALL SECTION1/2" = 1'-0"A-5027GARAGE CEILING MAIN FLOOR1' -8 1/4"UPPER PLATE20' -7 1/4"T.O. FOUNDATION0' -0"T.O. FOUNDATION0' -0"MAIN PLATE10' -9 3/8"MAIN PLATE10' -9 3/8"UPPER FLOOR12' -6 1/8"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"UPPER FLOOR PLATE HEIGHT8' - 1 1/8"GARAGE PLATE HEIGHT10' - 9 3/8"VINYL BOARD& BATTEN TYP.CULTURED STONEW/ CONCRETE CAPALUMINUM SOFFIT& FASCIA TYP.3' - 6"SEE COLUMN DETAILSHEET A-5016" SMARTSIDE FRIEZE BOARD TYP.VINYL LAPSIDING TYP. @ FRONT4" SMARTSIDE TRIM@ WINDOWS & DOORS AT FRONTADDRESS STONE1' - 0"8" 12"7" / 12"7" / 12"8:128" 12"DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/19/2024 2:02:09 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18365 GLACIER WAYLAKEVILLE, MN 55044A-201OTT4566.19.24 CB1682149511835.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNA1/4" = 1'-0"A-2011FRONT ELEVATIONSHEET INDEXSHEET NUMBER SHEET NAMEA-201 ELEVATIONA-202 ELEVATIONS/ ROOF PLANA-401 FOUNDATION PLANA-402 LOWER FLOORA-403 MAIN FLOORA-404 UPPER FLOORA-501 SCHEDULES/ DETAILSA-502 DETAILS 24" RETURN TYP.8" / 12"8" / 12"8" / 12"7" 12"4" / 12"8" / 12"ALUMINUM SOFFIT& FASCIA TYP.VINYL SIDING &CORNERS TYP.8" 12"8" 12"4" 12"4" / 12"24" RETURN TYP.8" / 12"8" / 12"8" / 12"4" 12"STANDARD ENERGY HEELS @ 8:1218" OVERHANGS & 12" RAKES TYP.7 ROOF VENT REQUIRED STANDARD ENERGY HEELS @ 4:12 W/ 7:12 & 8:12 FASCIA LINES TO MATCH3 ROOF VENTS REQUIRED 1 ROOF VENT REQUIRED 8" / 12"8" / 12"8" / 12"7" / 12"8" / 12"8" / 12"7" / 12"4" / 12"8" / 12"8" / 12"4" / 12"8" / 12"DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/19/2024 2:02:11 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18365 GLACIER WAYLAKEVILLE, MN 55044A-202OTT4566.19.24 CB1682149511835.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNA1/8" = 1'-0"A-2021RIGHT ELEVATION1/8" = 1'-0"A-2022REAR ELEVATION1/8" = 1'-0"A-2023LEFT ELEVATION1/8" = 1'-0"A-2024ROOF PLAN 9' - 10"18' - 6"30' - 6"0' - 2"20' - 6"10' - 0"1' - 4 1/2"8' - 3" M.O.0' - 4 1/2"2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL W/2" x 8" INTERIOR LEDGE ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.7'-8"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.0' - 4"*ALL DIMENSIONS ARETO EXTERIOR OFCONCRETE, NOT INSULATION2" FOAM INSULATIONBETWEEN WALL & SLAB8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.49' - 0"29' - 8"21' - 8"30' - 4"6' - 0"5' - 10"11' - 10"40' - 2"52' - 0"0' - 4"52' - 0"42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY19' - 4"42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY8' - 3 1/4"14' - 9"4' - 2 3/4"4' - 2 3/4"8' - 8 1/4"8'-4"(H) x 10"(W) POUREDCONCRETE FOUND. WALL W/4" x 8" EXTERIOR LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.9' - 9 1/4"11' - 10 3/4"9' - 1 1/4"10' - 2 3/4"30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY4' - 2 3/4"26' - 10 1/4"17' - 11"11' - 6"10' - 10"42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY, BOTH SIDES.4' - 2 3/4"25' - 5 1/4"13' - 9 1/4"3' - 2 3/4"32' - 0"17' - 0"49' - 0"2' - 0"6' - 0"22' - 4"19' - 8"2' - 0":LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODE30" x 30" x 12"CONCRETE FTG. W/ (3)#5 REBAR EACH WAY42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAYANCHOR BOLTS TO EACH SIDE OF BEARING POINT TYPICAL42" x 42" x 12" CONCRETE FTG.W/ (4) #5 REBAR EACH WAY5' - 10 3/4"8' - 1 3/4"5' - 3 1/2"4' - 4 1/2"3' - 3" M.O.12' - 0 1/2"DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/19/2024 2:02:11 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18365 GLACIER WAYLAKEVILLE, MN 55044A-401OTT4566.19.24 CB1682149511835.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNA1/4" = 1'-0"A-4011FOUNDATION PLAN UNEXCAVATEDMECHANICAL /STORAGE9' - 10"11' - 10"20' - 6"10' - 0"0' - 2"18' - 6"30' - 6"40' - 2"5' - 10"6' - 0"12' - 11"27' - 3"8' - 11"4' - 0"4' - 0"23' - 3"UNEXCAVATED9' - 2"7' - 10"7' - 3"7' - 3"8' - 9"8' - 9"52' - 0"SET SILL 6" ABOVE TREATED PLATE 0' - 4"*ALL DIMENSIONS ARE TOEXTERIOR OF CONCRETE ORSHEATHING, NOT INSULATION2" FOAM INSULATIONBETWEEN WALL & SLAB0' - 4"49' - 0"17' - 4 1/4"BEDROOM #4FAMILY ROOMSUMPR & SH.48" F.G. SHWR5' VANITYBATH2x6FURNACEAIR EX.6' - 0"5' - 10"37' - 2"40' - 2"11' - 10"21' - 8"30' - 4"52' - 0"19' - 4"CO DET.SMOKEDET.xxxx FLUSH2-2x103-2x105x5 PSL2' - 1 1/2"16' - 3" M.O.2' - 1 1/2"0' - 4 1/2"8' - 3" M.O.1' - 4 1/2"SMOKEDET.W. H.2-2x105' - 10"6' - 0"7' - 6"2' - 6"9' - 4"6' - 7"4' - 3"11' - 6"72/8 x 6/8R.O. 2' -10" x 6' -11"18" FLOOR TRUSSESPER MFG. SPACING62/6 x 6/8R.O. 2' -8" x 6' -11"29' - 8"6036E NVG114R.O. 6' -0" x 3' -6"H.H. 6' -10"4030 NVPWG TEMP.10R.O. 4' -0" x 3' -0"H.H. 11' -8"FROM LOWER FLOOR17' - 6"14' - 6"17' - 0"49' - 0"MECHANICAL CHASE ABOVE 2' - 0"6' - 0"22' - 4"19' - 8"2' - 0"ANCHOR BOLTS TO EACH SIDE OF BEARING POINT TYPICAL126/0 x 6/8R.O. 6' -2" x 6' -11"EQEQ2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.32/4 x 6/8R.O. 2' -6" x 6' -11"14' - 3"FLEX ROOM18" FLOOR TRUSSESPER MFG. SPACING6036E NVG114R.O. 6' -0" x 3' -6"H.H. 6' -10"6036E NVG114R.O. 6' -0" x 3' -6"H.H. 6' -10"W.S.4' - 4 1/2"3' - 3" M.O.12' - 0 1/2"2x632/4 x 6/8R.O. 2' -6" x 6' -11"72/8 x 6/8R.O. 2' -10" x 6' -11"6' - 6"DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/19/2024 2:02:13 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18365 GLACIER WAYLAKEVILLE, MN 55044A-402OTT4566.19.24 CB1682149511835.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNA1/4" = 1'-0"A-4021LOWER FLOOR PLANXXXX*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***||[[[[[[2 - 1-3/4"x 9-1/2" LSL2-2x103 - 1-3/4"x 9-1/2" LSL3 - 1-3/4"x 14" LSL5x5 PSL5x5 PSLOK 40' - 0"12' - 0"36" REFSINKDWPORCH20' - 6"10' - 0"2' - 3"16' - 0"2' - 3"0' - 6"8' - 0"1' - 6"52' - 0"17' - 6"14' - 6"17' - 0"GARAGE30' - 0"4' - 0"4' - 6"7' - 8"5' - 0"22' - 0"30' - 0"52' - 0"FOYERGREAT ROOMDININGEQEQ10' - 0"RAILING KNEE WALL W/14" PAINTED SPINDELS 4' - 0"4' - 0"8' - 9"6' - 0"5' - 10"0' - 10"36' - 4"SEE COLUMN DETAILSHEET A-501ATTICACCESS2' - 0"6' - 0"22' - 0"20' - 0"2' - 0"18' - 6"30' - 6"6' - 0"6' - 0"5' - 3"8' - 6"5' - 3"7' - 4 1/4"1' - 3"1' - 3"9' - 1 3/4"4' - 11"3' - 10"MECH CHASE17' - 6"12' - 6"DBL. FRAMED WALLFOR REFG. RECESSOVEN /MICRO3' - 3"3' - 6"3' - 9"4' - 9"6' - 9"2' - 6"5' - 0"9' - 0"16" SH.12" SH.PANTRYBATHFLEX ROOM9' - 0"4' - 7"36" GASCOOKTOPW/ WOOD HOOD ABOVE10" FLUSH S.B.6' - 0"14' - 0"8' - 7 1/4"13' - 4 3/4"8' - 9"8' - 9"7' - 0"7' - 6"10' - 6"6' - 6"0' - 5"9' - 4"8' - 9"FLOOR GIRDERKITCHENSTUDYR & SH.4-2x6XXXX FLUSH5x5 PSLGIRDER TRUSSGIRDER TRUSS5x5 PSL2-11 7/8" LSL2-11 7/8" LSL3-2x62-2x102-2x102-2x102-2x10FLUSH2-2x10FLUSH2-11 7/8" LSLFLUSHR-38 INSULATION INFLOOR ABOVE SMOKEDET.2-2x106'-10" ABOVE LANDINGRECYCLE7' - 2"2' - 6"9' - 4"MUD RM.19' - 0"3-14" LVL FLUSH49' - 0"14' - 6"11' - 4"END PANEL39"x73" FRIG RECESS2' - 9"4' - 0"2-9 1/2" LSLSTAGGERED UPPERS20" FLOOR TRUSSESPER MFG. SPACING20" FLOOR TRUSSESPER MFG. SPACING82/8 x 6/8 FIRE RATEDR.O. 2' -10" x 6' -10 1/4"42/4 x 6/8 FULL VIEWR.O. 2' -6" x 6' -11"72/8 x 6/8R.O. 2' -10" x 6' -11"113/0 x 6/8 W/ 12" D.S. SL'SSTEEL32/4 x 6/8R.O. 2' -6" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"1616' x 8' O.H. GARAGE DOORINSULATED158' x 8' O.H. GARAGE DOORINSULATEDMFG. ROOF TRUSSES@ 24" O.C.2-2x10 W/2 TRIMMERS MFG. ROOF TRUSSES@ 24" O.C.-55" LINEAR ELECTRIC FIREPLACE -SET 12" ABOVE FINISHED FLOOR W/ MANTEL WRAP AROUND SIDES 20" FLOOR TRUSSESPER MFG. SPACING2' - 0"12' - 9"22' - 11 3/4"4' - 3 1/4"3060E NVH28R.O. 6' -0" x 6' -0"H.H. 8' -0"4040 NVPWG TEMP.11R.O. 4' -0" x 4' -0"H.H. 12' -6 3/4"FROM MAIN FLOOR49' - 0"U.C. LIGHTS U.C.LIGHTS U.C. LIGHTS U.C.LIGHTS 32/4 x 6/8R.O. 2' -6" x 6' -11"R & SH.2020 NVPWG2R.O. 2' -0" x 2' -0"H.H. 8' -0"20" FLOOR TRUSSESPER MFG. SPACING0' - 5"5' - 7"5' - 0"2-2x10136/0 x 6/8 FULL VIEW W/ GRIDSR.O. 6' -2" x 6' -11"103/0 x 6/8 FULL VIEW FIXED W/GRIDSR.O. 3' -2" x 6' -11"1032/4 x 6/8R.O. 2' -6" x 6' -11"52/4 x 6/8 PKTR.O. 4' -10" x 6' -11"12/0 x 6/8R.O. 2' -2" x 6' -11"XXXX DROPPED XXXX FLUSHXXXX FLUSHXXXX FLUSH2640 NVH14R.O. 2' -6" x 4' -0"H.H. 6' -10"60" F.G. SHWR3'-6" VANITY3060E NVH16R.O. 3' -0" x 6' -0"H.H. 8' -0"6146/0 x 6/8 SLIDERR.O. 6' -0" x 6' -8"COMFORT HEIGHT BUILT-INBUILT-IN93/0 x 6/8R.O. 3' -2" x 6' -10 1/4"4" CONCRETE SLAB, SLOPETOWARDS DOORS5/8" TYPE X GYP. BD. CEILING1/2" GYP. BD. ON GARAGE WALLSGARAGE PLATE HEIGHT TOMATCH MAIN FLOOR UNLESS NOTED OTHERWISE48" WIDE CONCRETE SIDEWALK TO DRIVEWAY INSULATE GARAGE WALLS AND CEILING 3060E NVH1-3660NVPWH-3060E NVH17R.O. 9' -6" x 6' -0"H.H. 8' -0"MFG. ROOF TRUSSES@ 24" O.C.SUNROOM2' - 6"3' - 6"2050 NVH23R.O. 4' -0" x 5' -0"H.H. 6' -10"1/4" = 1'-0"A-4031MAIN FLOOR PLANDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/19/2024 2:02:14 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18365 GLACIER WAYLAKEVILLE, MN 55044A-403OTT4566.19.24 CB1682149511835.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNAFloor TrussDo NOT let porch beam intogarage wall. Beam stops shortof wall to eliminate upliftsituation @ Garage wallbearing.*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***||[[[[[[[[[[[[[[[[2-2x10B2B1B3B4B53-2x10OK2-2x102-2x10OKOKOK2-2x102-2x102-2x10OK3-2x10 Cont.OK5x5 PSL3 - 1-3/4"x 11-7/8" LSL3 - 1-3/4"x 9-1/2" LSLOK2 - 1-3/4"x 9-1/2" LVL3 - 1-3/4"x 14" LSL5x5 PSL||[[[[[[4-2x6LUS210-23-2x63-2x63-TrimmersOK3 - 11-7/8" LVL3-Trimmers3-2x6 17' - 0"15' - 0"13' - 0"2' - 0"34' - 0"6' - 0"6' - 0"5' - 10"33' - 2"CO DET.SMOKEDET.SMOKEDET.38' - 0"6' - 0"PRIMARY SUITEBOX VAULTBEDROOM #2EN SUITE #2HALLBEDROOM #35' - 8 3/4"7' - 2"6' - 11 1/4"14' - 2"14' - 9"4' - 0"4' - 0"15' - 3"17' - 4 1/4"4' - 1 1/2"6' - 5"3' - 9"13' - 4 1/4"12' - 0"7' - 0"26' - 0"8' - 6"8' - 6"7' - 6"7' - 6"6' - 6"6' - 6"18' - 9"19' - 3"6' - 0"6' - 0"3' - 4 7/8"3' - 7 1/8"23' - 10"10' - 2"12' - 2"6' - 5 3/4"13' - 0"7' - 8 1/2"5' - 7 3/4"2-2x103-2x10KNEE WALLW/ 14" PAINTED SPINDLES MFG. ROOF TRUSSES@ 24" O.C.MFG. ROOF TRUSSES@ 24" O.C.ATTICACCESS10'-10" ABOVE LANDING45' - 0"7' - 8"5' - 6"7' - 11 1/4"5' - 1 3/4"PRIMARY BATHLAUNDRYMFG. ROOF TRUSSES@ 24" O.C.PRIMARYCLOSETEN SUITE #345' - 0"2-2x102-2x1044' - 0"42' - 0"5' - 11"7' - 10"SMOKEDET.2020 NVA11R.O. 2' -0" x 2' -0"H.H. 6' -10"4030 NVPWG TEMP.10R.O. 4' -0" x 3' -0"H.H. 6' -10"6020 NVFA313R.O. 6' -0" x 2' -0"H.H. 5' -8 7/8"FROM UPPER FLOOR8050E NVGE15R.O. 8' -0" x 5' -0"H.H. 6' -10"72/8 x 6/8R.O. 2' -10" x 6' -11"12' - 2"HALF WALL 5040E NVG112R.O. 5' -0" x 4' -0"H.H. 6' -10"13' - 9"62/6 x 6/8R.O. 2' -8" x 6' -11"62/6 x 6/8R.O. 2' -8" x 6' -11"R & SH.6' VANITY22/4 SHWR DR.3' x 5' TUB W/ TILEDECK32/4 x 6/8R.O. 2' -6" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"2' LINEN2' - 4"18' - 11"4' - 9"3040E NVC15R.O. 3' -0" x 4' -0"H.H. 6' -10"2020 NVA11R.O. 2' -0" x 2' -0"H.H. 6' -10"5040E NVG112R.O. 5' -0" x 4' -0"H.H. 6' -10"TYP.2' - 0"2' LINEN4' VANITY5' TUB/SHWR5' TUB/SHWR4' VANITYSMOKEDET.LOFTR & SH.R & SH.R & SH.R & SH.CLOSET #2CLOSET #33636 NVG19R.O. 3' -6" x 3' -6"H.H. 6' -10"2x6MFG. ROOF TRUSSES@ 24" O.C.WASHERDRYERSINK3' - 7"72/8 x 6/8R.O. 2' -10" x 6' -11"62/6 x 6/8R.O. 2' -8" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"32/4 x 6/8R.O. 2' -6" x 6' -11"2' - 0"5' - 11"3' - 5"3' LINENTILE SHOWER4' - 5 3/4"6' - 5"4' - 1 1/4"42" HALF WALL W/ GLASS PANEL ABOVE DATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/19/2024 2:02:15 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18365 GLACIER WAYLAKEVILLE, MN 55044A-404OTT4566.19.24 CB1682149511835.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNA1/4" = 1'-0"A-4041UPPER FLOOR PLAN*** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ****** Header Spans ***Up to 4' 11" = 1 Trimmer5' 0" and Larger = 2 Trimmers*** Unless Noted Otherwise ***||[[[[[[[[[[[[[[[[OKOK2-2x102-2x102-2x102-2x102-2x10OK2 - 1-3/4"x 9-1/2" LSL 1' - 5"0' - 9 1/2"2x4 @ BOTTOM1x3 TYP.2x22x4 @ TOPSMOOTH LPSMARTSIDE TYP.SOFFIT1' - 9 1/2"1' - 0"FRONTSIDETOP VIEW1' - 5"0' - 9 1/2"FRAMING4x4 POSTDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/19/2024 2:02:16 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18365 GLACIER WAYLAKEVILLE, MN 55044A-501OTT4566.19.24 CB1682149511835.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNAWINDOW SCHEDULETYPE MARK MANUFACTURER MODEL COUNT UNIT ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT1 VECTOR ENVISION SERIES 2 2020 NVA1 2' - 0" 2' - 0" 6' - 10"2 VECTOR ENVISION SERIES 1 2020 NVPWG 2' - 0" 2' - 0" 8' - 0"3 VECTOR ENVISION SERIES 1 2050 NVH2 4' - 0" 5' - 0" 6' - 10"4 VECTOR ENVISION SERIES 1 2640 NVH1 2' - 6" 4' - 0" 6' - 10"5 VECTOR ENVISION SERIES 1 3040E NVC1 3' - 0" 4' - 0" 6' - 10"6 VECTOR ENVISION SERIES 2 3060E NVH1 3' - 0" 6' - 0" 8' - 0"7 VECTOR ENVISION SERIES 1 3060E NVH1-3660 NVPWH-3060E NVH1 9' - 6" 6' - 0" 8' - 0"8 VECTOR ENVISION SERIES 1 3060E NVH2 6' - 0" 6' - 0" 8' - 0"9 VECTOR ENVISION SERIES 1 3636 NVG1 3' - 6" 3' - 6" 6' - 10"10 VECTOR ENVISION SERIES 2 4030 NVPWG TEMP. 4' - 0" 3' - 0" VARIES11 VECTOR ENVISION SERIES 1 4040 NVPWG TEMP. 4' - 0" 4' - 0" 12' - 6 3/4"12 VECTOR ENVISION SERIES 2 5040E NVG1 5' - 0" 4' - 0" 6' - 10"13 VECTOR ENVISION SERIES 1 6020 NVFA3 6' - 0" 2' - 0" 5' - 8 7/8"14 VECTOR ENVISION SERIES 3 6036E NVG1 6' - 0" 3' - 6" 6' - 10"15 VECTOR ENVISION SERIES 1 8050E NVGE 8' - 0" 5' - 0" 6' - 10"ROOM FINISH SCHEDULEFLOOR NAME FLOOR FINISH AREA PLATE HEIGHT COMMENTSLOWER FLOOR MECHANICAL / STORAGE CONCRETE 138 SF 8' - 2"LOWER FLOOR BEDROOM #4 CARPET 227 SF 8' - 2" .LOWER FLOOR FAMILY ROOM CARPET 439 SF 8' - 2" .LOWER FLOOR BATH VINYL 53 SF 8' - 2" .LOWER FLOOR STAIRWAY CARPET 84 SF 8' - 2"LOWER FLOOR FLEX ROOM 346 SF 8' - 2"MAIN FLOOR PORCH CONCRETE 111 SF 9' - 1 1/8"MAIN FLOOR GARAGE CONCRETE 614 SF 10' - 9 3/8"MAIN FLOOR FOYER WOOD 80 SF 9' - 1 1/8" .MAIN FLOOR GREAT ROOM WOOD 252 SF 9' - 1 1/8" .MAIN FLOOR DINING WOOD 159 SF 9' - 1 1/8" .MAIN FLOOR PANTRY VINYL 24 SF 9' - 1 1/8" .MAIN FLOOR BATH VINYL 72 SF 9' - 1 1/8" .MAIN FLOOR FLEX ROOM CARPET 144 SF 9' - 1 1/8" .MAIN FLOOR KITCHEN WOOD 281 SF 9' - 1 1/8" .MAIN FLOOR STUDY WOOD 56 SF 9' - 1 1/8" .MAIN FLOOR MUD RM. VINYL 33 SF 9' - 1 1/8" .MAIN FLOOR STAIRWAY CARPET 94 SF 9' - 1 1/8"MAIN FLOOR SUNROOM 124 SF 9' - 1 1/8"UPPER FLOOR PRIMARY SUITE CARPET 242 SF 8' - 1 1/8" BOX VAULTUPPER FLOOR BEDROOM #2 CARPET 171 SF 8' - 1 1/8" .UPPER FLOOR EN SUITE #2 VINYL 59 SF 8' - 1 1/8" .UPPER FLOOR HALL CARPET 134 SF 8' - 1 1/8" .UPPER FLOOR BEDROOM #3 CARPET 189 SF 8' - 1 1/8" .UPPER FLOOR PRIMARY BATH TILE 130 SF 8' - 1 1/8"UPPER FLOOR LAUNDRY VINYL 53 SF 8' - 1 1/8"UPPER FLOOR PRIMARY CLOSET CARPET 110 SF 8' - 1 1/8"UPPER FLOOR EN SUITE #3 CARPET 59 SF 8' - 1 1/8"UPPER FLOOR LOFT 168 SF 8' - 1 1/8"UPPER FLOOR CLOSET #2 50 SF 8' - 1 1/8"UPPER FLOOR CLOSET #3 48 SF 8' - 1 1/8"DOOR SCHEDULETYPE MARK DOOR SIZES ROUGH WIDTH ROUGH HEIGHT COUNT COMMENTS1 2/0 x 6/8 2' - 2" 6' - 11" 12 2/4 SHWR DR. 13 2/4 x 6/8 2' - 6" 6' - 11" 124 2/4 x 6/8 FULL VIEW 2' - 6" 6' - 11" 1 FROSETED GLASS5 2/4 x 6/8 PKT 4' - 10" 6' - 11" 16 2/6 x 6/8 2' - 8" 6' - 11" 57 2/8 x 6/8 2' - 10" 6' - 11" 48 2/8 x 6/8 FIRE RATED 2' - 10" 6' - 10 1/4" 19 3/0 x 6/8 3' - 2" 6' - 10 1/4" 110 3/0 x 6/8 FULL VIEW FIXED W/ GRIDS 3' - 2" 6' - 11"211 3/0 x 6/8 W/ 12" D.S. SL'S STEEL 112 6/0 x 6/8 6' - 2" 6' - 11" 113 6/0 x 6/8 FULL VIEW W/ GRIDS 6' - 2" 6' - 11" 114 6/0 x 6/8 SLIDER 6' - 0" 6' - 8" 115 8' x 8' O.H. GARAGE DOOR INSULATED 116 16' x 8' O.H. GARAGE DOOR INSULATED 11/2" = 1'-0"A-5012TYPICAL COLUMN3" MIN. ABS OR PVC GASTIGHT PIPE FROM SUBSLAB TO MIN.12" ABOVE ROOF, MUST BE RUN THRU CONDITIONED SPACE.PIPE CAN BE CONNECTED TO SUMP SYSTEM OR HAVE"T" FITTING (MIN. 10'-0" EA. WAY) IN GRAVEL UNDER SLAB.END OF PIPE MUST BE MIN. 10'-0" AWAY FROM ANY WINDOW OROTHER OPENING THAT IS LESS THAN 2'-0" BELOW END OF PIPE. END OF PIPE MUST ALSO BE MIN. 10'-0" AWAY FROM ANYWINDOW OR OTHER OPENING IN ADJOINING OR ADJACENT BUILDINGS.SUFFICIENT SPACE MUST BE LEFT AROUND PIPE IN ATTIC SPACETO ADD FAN. SPACE MUST BE MIN. ∅24" CENTERED ON AXIS OFPIPE W/ MIN. 3'-0" VERTICAL SPACE.A SINGLE PIPE CAN BE USED IF ALL SOIL GASES IN DWELLING CANFLOW FREELY BETWEEN ALL LEVELS OF FOUNDATION. THIS INCLUDESINTERIOR FOOTINGS & OTHER BARRIERS IF AIRFLOW HAS BEEN ESTABLISHED.LABEL THE VENT PIPE AT LEAST ONCE PER FLOOR AND IN ACCESSIBLE ATTICSWITH "RADON REDUCTION SYSTEM".ONE ELECTRICAL RECEPTACLE IS REQUIRED IN THE ATTIC NEARTHE VENT PIPE FOR OPT. FAN.:PASSIVE RADON SYSTEM: WATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALER6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETRT'D 2x8 SILL PLATEW/ CLOSED CELL ROLLSILL SEALERGRADEGRANULAR FILL4" DRAIN TILEW/ SILT SOCK1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOORLOWER PLATE HEIGHT8' - 2"MAIN FLOOR PLATE HEIGHT9' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.VERIFY FLOOR SYSTEMWITH FLOOR PLANSUPPER FLOOR PLATE HEIGHT8' - 1 1/8"6 MIL. V.B.1/2" GYP. BD.3/4" T&GSUBFLOOR6 MIL. V.B.2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION2x6 STUDS @ 16" O.C.W/ R-21 F.G. INSULATION8'-4"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.1/2" OSBSHEATHINGTYVEK (OR EQUAL)ROLL HOUSE WRAPSIDING, VERIFYW/ ELEVATIONS5/8" GYP. BD.5/8" GYP. BD.VENTED ALUMINUMSOFFIT PANELSICE & WATER GUARDFROM EAVE TO 2'-0"MIN. OVER STRUCTUREVENT CHUTES & WIND WASH@ EACH TRUSS SPACEASPHALT SHINGLES W/15# ROLL FELT UNDER1/2" OSB ROOF SHEATHINGMFG. ROOFTRUSSES @ 24" O.C.ATTIC VENTINGAS PER CODER-49 MIN. BLOWNATTIC INSULATIONALUMINUM FASCIA W/2x6 SUB FASCIAALUMINUMDRIP EDGERIM JOISTRIM JOISTR-20 MIN. SPRAYFOAM INSULATION,COVER FOUNDATION WALLGMX THERMAL DRAINAGE BOARD(R-10) INSULATIONDRYVIT INSULATIONPROTECTION FROM SIDINGTO 6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITH OUTSIDE OF SHEATINGR-20 MIN. SPRAYFOAM INSULATION6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEGRANULAR FILL:WALKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALLW/ 2" x 4" INT. LEDGE ON20" x 8" CONCRETE FTG'S.REBAR PER CODE.POLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSMIN.0' - 6"5000 PSI CONCRETE@ ALL FOOTINGS2" FOAMBOARD(R-10) INSULATION4" DRAIN TILEW/ SILT SOCKWATER PROOF COATING FROM FOOTING TOSILL SEALERWATER PROOF COATINGFROM FOOTING TOINSIDE OF WALL6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODETYPICAL 2x6EXTERIOR WALLTRT'D 2x6 SILL PLATEW/ ROLL SILL SEALERGRADEMIN.0' - 6"GRANULAR FILL4" DRAIN TILEW/ SILT SOCK:LOOKOUT WALL:2x6 STUDS @ 16" O.C. ON3'-6"(H) x 8"(W) POUREDCONCRETE FOUND. WALL ON20" x 8" CONCRETE FTG.REBAR PER CODEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTS1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGESINSULATION & SEALANT TOBE CONT. OVER WALL2" FOAMBOARD(R-10) INSULATIONINSULATION PROTECTIONFROM SIDING TO6" BELOW GRADE5000 PSI CONCRETE@ ALL FOOTINGS*OUTSIDE OF FOUNDATION TO ALIGN WITHOUTSIDE OF SHEATHINGANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)VERIFY FLOOR SYSTEMWITH FLOOR PLANS3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" OSBSHEATHINGRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESTOOP, FLASH AS REQ'DAT HOUSE WALLPOUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERSIDING, VERIFYW/ ELEVATIONSTYVEK (OR EQUAL) ROLL HOUSE WRAP0' - 2"FROM SHEATHING TOOUTSIDE OF FOUNDATIONANCHOR BOLTPER CODETRT'D 2x6 SILL PLATEW/ ROLL SILL SEALER1" FOAMBOARD (R-5) INSULATIONW/ ACOUSTICAL SEALANT @ TOP& BOTTOM EDGES, BETWEEN INSUL.& SLAB & AT ALL VERTICAL EDGES(ONLY WHEN REQUIRED BY CODE)3/4" T&GSUBFLOOR6 MIL. V.B.1/2" GYP. BD.2x6 STUDS @ 16" O.C.W/ R-20 F.G. INSULATION1/2" GYP BOARD,TAPE & MUD ALL SEAMSRIM JOISTR-20 MIN. SPRAYFOAM INSULATIONGMX THERMAL DRAINAGE BOARD(R-10) INSULATION5/8" GYP. BD., TAPE& MUD ALL SEAMSSLOPED CONCRETESLAB, FLASH AS REQ'DAT HOUSE WALL0' - 4"POUREDFND. WALLWATCH DOG WATER PROOFCOATING FROM FOOTING TOSILL SEALERVERIFY FLOOR SYSTEMWITH FLOOR PLANS2x6 STUDS @ 16" O.C. ONHALF-HIGH 6" BLOCK ON16" x 8" CONCRETE FTG'S.REBAR PER CODE.TRT'D SILL PLATEPOLYURETHANE CAULKOR ELASTOMERICSEALANT @ ALL JOINTSSLEEVE EVERY10'-0" MIN.6 MIL POLY V.B., OVERLAPEDGES MIN. 12" & TAPE.SEAL ALL OPENINGS4" MIN. LAYER3/4" RIVER ROCK3 1/2" CONCRETE SLABANCHOR BOLTPER CODE5000 PSI CONCRETE@ ALL FOOTINGSALL DUCT WORK & PLUMBING TO REMAIN ABOVE INSULATIONTYVEK OR EQUALHOUSE WRAP5/8" TYPE 'X'GYP. BD., TAPE &MUD ALL SEAMS1" RIGID INSULATION3/4" T&G SUBFLOORR-30 MIN.BLOWN INSULATIONFLOOR TRUSSDATEFINISHED SQUARE FEETPROJECTSHEETUPPER:MAIN:LOWER:RELEASEDREV. 1REV. 2REV. 3REV. 4REV. 5PRELIMINARY -NOT FOR CONSTRUCTIONPLATE HEIGHTSUPPER:MAIN:FOUND:UNSPECIFIED HEADERS TO BE 2-2x10 W/ 2 TRIMMERS10" MIN. STAIR TREAD DEPTH & 7 3/4" MAX STAIR RISER HEIGHTALL ANGLES ARE 45 DEGREES UNLESS NOTED OTHERWISEALL EXTERIOR DIMENSIONS ARE TO OUTSIDE OF SHEATHING, CONCRETE OR FOUNDATION INSULATIONTOTAL:THE IDEAS, DESIGNS, DRAWINGS AND SPECIFICATIONS REPRESENTED HEREIN ARE AND SHALL REMAIN THE EXCLUSIVE COPYRIGHT PROPERTY OF ONETENTEN HOMES. NO PART THERE OF SHALL BE USED, COPIED, OR DISCLOSED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF ONETENTEN HOMES.THE PLANS FURNISHED HEREINWERE PREPARED UPON REQUEST BY DRAFTSPERSONS WHO ARE NOT REGISTERED ARCHITECTS OR ENGINEERS. ONETENTEN HOMES ASSUMES NO RESPONSIBILITY FOR STRUCTURAL OR DIMENSIONAL ERRORS OR OMISSIONS.THE CONTRACTOR AND/OR OWNER MUST VERIFY AND CHECK ALL NOTES DETAILS, ELEVATIONS, SECTIONS AND FLOOR PLANS AND NOTIFY ONETENTEN HOMES OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. NO WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING COMPLIANCE OF THIS PLAN WITH APPLICABLE BUILDING CODE REQUIREMENTS. THE SELECTION AND APPLICATION OF CORRECT STRUCTURAL MATERIALS IS THE RESPONSIBILITY OF THE BUILDER, THE OWNER OR THE USER OF THESE PLANS.3000 COUNTY ROAD 42 WEST, SUITE 302BURNSVILLE, MN 55337PH (952) 953-4000ONETENTENHOMES.COMP.O. BOX 3915411 LAKERS LANE, SUITE 204NISSWA, MN 56468PH (218) 232-6031MARKA.DESIGN6/19/2024 2:02:17 PMTHE ASLAM & SHAIKHRESIDENCEL5, B3 - GLACIER CREEK 4TH ADD'N18365 GLACIER WAYLAKEVILLE, MN 55044A-502OTT4566.19.24 CB1682149511835.17.24 CB8'-1 1/8"9'-1 1/8"8'-4" POUR4360THE SAVANNA3/8" = 1'-0"A-5021TYP. WALL SECTION1/2" = 1'-0"A-5022TYP. WALKOUT SECTION1/2" = 1'-0"A-5023TYP. LOOKOUT SECTION1/2" = 1'-0"A-5024TYP. HOUSE/STOOP WALL1/2" = 1'-0"A-5025TYP. HOUSE/GARAGE WALL1/2" = 1'-0"A-5026BEARING WALL SECTION1/2" = 1'-0"A-5027GARAGE CEILING COPYRIGHT HANSON GROUP, LLC 2024©August 12, 2024Project Number:Date:4.352S11Sheets: of1PLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.DescriptionDateRevisionAslam & Shaikh Residence18365 Glacier WayLakeville, MN5851 Cedar Lake RoadSuite 202St. Louis Park, MN 55416Tel 612-708-3572www.hansongroupmn.comPrint Name:Signed: License Number:8-12-24Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.OneTenTen Homes3000 County Road 42 WSuite 302Burnsville, MN 55337Garrett Brunell52600UPPER LEVEL PLAN SHOWN FORLOCATION REFERENCE ONLY3S1REFERENCE PLANMAIN FLOOR PLAN SHOWN FORLOCATION REFERENCE ONLY2S1REFERENCE PLANINDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ON EXTERIOR FACE IN ACCORDANCE w/ FRAMING NOTE 1.PROVIDE INCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TO BE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)(MIN. LENGTH)THESE SHEETS REPRESENT A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRE RESIDENTIAL STRUCTURE.THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WIND RESISTING ELEMENT THAT IS REQUIRED FOR THE HANSONGROUP'S DESIGN IS SHOWN ON THE STRUCTURAL DRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUM SHEATHING BOTH FACES WITH EITHER FASTENER OPTION LISTED INFRAMING NOTE 2, SPACED AT 4" O.C. PROVIDE INCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TO ROOF TRUSSESABOVE, TO TRUSSES/BLOCKING ABOVE, AND TO TRUSSES/BLOCKING BELOW. THESE PANELSARE NOT NECESSARILY REQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.EXTERIOR NON-BEARING WALLFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)w/ TRUSSESw/ TRUSSESROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIPNAIL BOTTOM PLATETO RIBBON BRACE /TRUSS w/ (3) 16dNAILS EVERY 16"2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHNAIL EACH TRUSS TOTOP PLATES w/ (3)0.131"Ø x 3" TOENAILSROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO LADDERTRUSS w/ (3) 16dNAILS EVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/0.131"Ø x 3"NAILS @ 6" O.C.w/ TRUSSESw/ TRUSSESINTERIOR WALLPERPENDICULAR TO FRAMINGINTERIOR WALLPARALLEL w/ FRAMING2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN TRUSSESNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH TRUSS TO TOP PLATEw/ (3) 0.131"Ø x 3" TOENAILSPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSS DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATE w/(3) 16d NAILS EVERY 16"(OR AS SHOWN TOTHE RIGHT IF REQ'D)FASTEN PLATE w/ 14" CONCRETESCREWS OR POWDERACTUATED 0.145" WASHEREDPINS @ 16" O.C. w/ 1"EMBEDMENT IN CONCRETESCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM AT A SINGLE FAMILY RESIDENCE.CONSTRUCTION IS TO BE IN ACCORDANCE WITH THESE DRAWINGS, STANDARD INDUSTRY PRACTICE, AND THEREQUIREMENTS OF THE CODE.GENERAL NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO HOUSE PLANS PREPARED BY MARKAARCHITECTURE LAST DATED 6-19-24 FOR MORE INFORMATION.2.THE HANSON GROUP'S ENGINEERING IS LIMITED TO THE ITEMS LISTED IN THE PROJECT SCOPE ABOVE.THE DESIGN OF THE REMAINING HOME, INCLUDING ALL BEAM AND HEADER SIZES, FOUNDATION WALLS, PADFOOTINGS, ETC IS BY OTHERS.3.IT IS THE RESPONSIBILITY OF THE BUILDER TO PROVIDE ALL FUTURE PLAN CHANGES TO THE HANSONGROUP FOR REVIEW. IF FINAL TRUSS LAYOUTS VARY FROM THOSE SHOWN ON HOUSE PLANS, NOTIFYENGINEER PRIOR TO CONSTRUCTION.4.CONTRACTOR AND BUILDER ARE TO VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDING WITHWORK. NOTIFY THE HANSON GROUP IF DISCREPANCIES ARISE.5.MEANS AND METHODS OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR.FRAMING NOTES1.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.,WHICH MEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x6 STUDS SPACED @ 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C ATPANEL EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.2.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C.MAX. OR TYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)3.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS.4.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIP OR EQUIVALENT AND (4) 0.131"Ø x3" TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.5.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12)0.131"Ø x 3" IN LAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3"FACE NAILS.6.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).7.TALL WOOD WALL FRAMING IS TO BE DESIGNED BY SUPPLIER FOR GRAVITY AND OUT-OF-PLANE WINDLOADS.8.THE ENTRY PORCH IS CONSIDERED TO BE A PRIMARILY OPEN, NON-ESSENTIAL PORTION OF THESTRUCTURE AND IS EXCLUDED FROM THE OVERALL MAIN WINDFORCE SYSTEM OF THE HOME. PROVIDECODE REQUIRED UPLIFT CONNECTIONS AT ALL POSTS.MATERIALSWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLSL STUDS:112" WIDTH - 1.3E OR BETTERLOADSROOF LIVE LOAD: 35 PSF (SNOW)ROOF DEAD LOAD:15 PSFFLOOR LIVE LOAD:40 PSFFLOOR DEAD LOAD:15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODE2020 MINNESOTA RESIDENTIAL CODEBRACEDWALL LINEBRACED WALL LINE (4-FT) (4-FT) BRACED WALL LINE(3.75-FT)(4-FT)BRACEDWALL LINE(4-FT)(3.5-FT)(4-FT)(4-FT)(4-FT)(4-FT) (4-FT)(4-FT) BRACED WALL LINE(7.1-FT)ONE-SIDEBRACEDWALL LINEBRACEDWALL LINEBRACED WALL LINE BRACED WALL LINE (6-FT)(16.4-FT)ONE-SIDEBRACEDWALL LINE(4-FT)(5-FT)(4.5-FT)CONSTRUCT GARAGE PORTALFRAME AS SHOWN IN 4/S1(4-FT) (6-FT)(4-FT)(4-FT)(4-FT)(3.5-FT)(4-FT)(4-FT)PARTIAL LOWER LEVEL FLOORPLAN SHOWN FOR LOCATIONREFERENCE ONLY1S1REFERENCE PLAN(11.4-FT)ONE-SIDES1FRAMING DETAILGARAGE FRONT PORTAL FRAME4NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.16'-3"±10'-938"±FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT STUD EACH END OF HEADERLOCATE PANEL JOINT WITHIN 2'-0" FROM CENTEROF HEADER HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x6 BEARING STUDS MIN.(VERIFY w/ SUPPLIER)PROVIDE 2x6 INFILL WALLABOVE HEADER AS REQ'DSIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 5/S1 FOR ALTERNATIVE OPTION)FOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADER(2) 58" Ø ANCHOR BOLTS (7" MIN. EMBED)w/ 2" x 2" x 316" PLATE WASHERSNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/ (2)ROWS 8d NAILS @ 3" O.C. STAGGERED & TOPLATES / BLOCKING @ 3" O.C.)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.LARGE HATCH AREA INDICATES 716" OR THICKERPLYWOOD OR OSB SHEATHING APPLIED TO EXTERIORSIDE OF STUDS w/ STANDARD 6"/12" NAILINGFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELS2'-112"±2'-112"±CONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN.312" WIDTH & MIN.1114" DEPTH REQ'D)PROVIDE TOP OF WALLCONNECTIONS SHOWN FORBRACED WALL PANELS ALONGINDICATED PORTION OF WALLBRACED WALL LINE (7.5-FT)SHEATH ONE-SIDE w/PLYWOOD/OSB PERFRAMING NOTE 1(4-FT)(4-FT)(4-FT)BRACEDWALL LINE(4-FT)(4-FT)(4-FT)(4-FT)CONCRETEFOUNDATIONBELOWSIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWN w/12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHORPOST-INSTALLED HOLDOWN OPTION5S1FRAMING DETAIL FLUSH XXX-PLY XXX" LVL18" DEEP TRUSSES24" O.C. BASE SPACING.DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING. TRUSSES HAVE BEEN HELD IN1/2" AT EXTERIOR WALLS FOR SHEATHING.THE PAINTED END DENOTES THE LEFT ENDOF THE FLOOR TRUSS. THIS END OF THEFLOOR TRUSS IS TO BE PLACED WHERE YOUSEE THE TRIANGLE AND THE PAINTED ENDNOTE ON THE PLACEMENT PLAN. THEPAINTED END ALSO CORRESPONDS TO THELEFT SIDE OF THE SEALED TRUSS DRAWING.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBINGLOCATIONS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLJOSH @ 651-287-1944OREMAIL: JRUDESILL@VILLAUME.COMPAINTED ENDPAINTED ENDPAINTED ENDF12-F17F12F2F13F9F15F16F11F1F11F1F11F1F1F1F10F4F4F4F6F6F6F6F6F7F7F7F8F8F8F8F14F14F14F14F14F14F14F3F11F11F8F8F6F19F17F17F17F17F17F17F17F17F18F623-03-004-00-004-00-0010-00-0022-00-00 6-00-0040-00-0040-00-0030-00-0019-00-0049-00-0017-00-0014-06-0017-06-0049-00-001-10-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-004-00-001-10-002-00-002-00-002-00-002-00-0011-10-002-00-002-00-002-00-002-00-002-00-001-06-002-00-001-04-001-04-002-00-008-00Customer: Lyman Lumber - ChanhassenJob Number: 327912-CHome Owner: TOPAZ / SAVANNA / ASLAM SHAIKH RESJob Name: 1st FloorSite Address: 18365 GLACIER WAY Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Josh Rudesill2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 7/23/2024Version: 8.7.3.303 POST-UP TOG2 HEREUSE (10) HUS26 TOBUILD KNEE WALLOF B/C OF G2G211493 / - lbHorizontal: - / - lbG214795 / - lbHorizontal: - / - lbH57449 / - lbHorizontal: - / - lbH510173 / - lbHorizontal: - / - lbFLUSH (2) 2X10FLUSH 3-PLY 14" LVLFLUSH 2-PLY 11-7/8" LVLFLUSH xxx-PLY xxx" LVLFLUSH 3-PLY 11-7/8" LVL20" DEEP TRUSSES24" O.C. BASE SPACING.DIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING. TRUSSES HAVE BEEN HELD IN1/2" AT EXTERIOR WALLS FOR SHEATHING.THE PAINTED END DENOTES THE LEFT ENDOF THE FLOOR TRUSS. THIS END OF THEFLOOR TRUSS IS TO BE PLACED WHERE YOUSEE THE TRIANGLE AND THE PAINTED ENDNOTE ON THE PLACEMENT PLAN. THEPAINTED END ALSO CORRESPONDS TO THELEFT SIDE OF THE SEALED TRUSS DRAWING.PLUMBING LOCATIONS ARE ESTIMATED.CONTRACTOR TO VERIFY PLUMBINGLOCATIONS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLJOSH @ 651-287-1944OREMAIL: JRUDESILL@VILLAUME.COMPAINTED ENDFF15FF5FF18FF18FF14FF4FF14FF3FF14FF3FF2FF13FF2FF12FF12FF12FF12FF9FF9FF9FF9FF9FF10FF10FF10FF1FF6FF7FF8FF17FF17FF17FF17FF17FF17FF17FF10FF9FF14FF17FF11FF10FF10FF16FF16FF13G2H5LUS410LUS410LUS410LUS410LUS410LUS410LUS410LUS410THGQ2-SDS3LUS24LUS24HUS28LUS24LUS410LUS410LUS410LUS410LUS410LUS41015-03-004-00-004-00-002-00-0020-00-0022-00-00 6-00-0050-00-0012-00-0040-00-0052-00-0010-00-0020-06-0018-06-0049-00-0017-00-0015-00-0017-00-0049-00-0036-00-0012-00-002-00-0034-00-0026-00-001-10-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-001-10-002-00-002-00-002-00-002-00-001-00-002-00-006-00-005-0013-00-002-00-002-00-002-00-004-00-002-00-002-00-007-00-002-00-002-00-00Customer: Lyman Lumber - ChanhassenJob Number: 327912-CHome Owner: TOPAZ / SAVANNA / ASLAM SHAIKH RESJob Name: 1st FloorSite Address: 18365 GLACIER WAY Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Josh Rudesill2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 7/23/2024Version: 8.7.3.303 POST-UP TOG2 HEREG211493 / - lbHorizontal: - / - lbG214795 / - lbHorizontal: - / - lbH57449 / - lbHorizontal: - / - lbH510173 / - lbHorizontal: - / - lbDIMENSIONS ARE FROM THE OUTSIDE OFSHEATHING.THE TRUSS ID DOES NOT DENOTE THE LEFTEND OF THE ROOF TRUSS ON THEPLACEMENT PLAN. USE THE LEFT END OFTHE SEALED TRUSS DRAWING AND THETRIANGLE ON THE PLACEMENT PLAN TOLOCATE THE PROPER END OF EACH ROOFTRUSS.DO NOT CUT TRUSSES.IF YOU HAVE ANY QUESTIONS OR CONCERNS,PLEASE CALLJOSH @ 651-287-1944OREMAIL: JRUDESILL@VILLAUME.COMG3G1G2H1H2H3H4H4H5M2M1M1M1M1M1M1M1M1M1M1N1N1N1N1J1J1K1K1K2K1L2L1L1L1L1L1L1L1L1L3TBE6THGQ2-SDS3LUS24LUS24LUS28LUS28LUS28HUS28LUS242-00-0020-00-0022-00-00 6-00-0050-00-0012-00-0040-00-0052-00-0010-00-0020-06-0018-06-0049-00-0017-00-0015-00-0017-00-0049-00-0036-00-0012-00-002-00-0034-00-0026-00-0013-00-002-00-001-11-042-00-001-10-087-00-002-00-002-00-00A3A2A2A2A2A2A2A2A2A2A2A1A1A1A1A1A2A4E1E1E2C1D1P2P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P22-00-081-10-122-00-0017-06-002-00-082-00-00Customer: Lyman Lumber - ChanhassenJob Number: 327912-CHome Owner: TOPAZ / SAVANNA / ASLAM SHAIKH RESJob Name: 1st FloorSite Address: 18365 GLACIER WAY Sales Rep: Josh RudesillCity, ST, ZIP: LAKEVILLE MN 55044 Designer: Josh Rudesill2926 Lone Oak Circle, St. Paul, MN 55121Ph: 651-454-3610 Fax: 651-454-4765Date: 7/23/2024Version: 8.7.3.303 Date Certificate Posted X Passive (No Fan) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here R-15 X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X X R-30 X X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: 90,000 Capacity in Gallons: Other, describe: AFUE or HSPF% 93 Cfm's " round duct OR 7" flex " metal duct Not required per mech. code X Passive Low: Other, describe: X Low: Location of fan(s), describe: Cfm's X " round duct OR 7" flex " metal duct City Mailing Address of the Dwelling or Dwelling Unit Combustion Air Select a Type Location of duct or system: 3 Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.8/12/2024 New Construction Energy Code Compliance Certificate Name of Residential Contractor One Ten Ten Homes, LLC MN License Number Lakeville18356 Glacier Way BC730925 Mechanical room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 63157 Heating Gain Cooling Load 88 Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.27 Appliances THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Non or Not Applicable Cooling SystemTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.32 Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) GPVL5000L 13ACX036P Model Heating System Natural Gas Lennox Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type AO Smith Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 14 175 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): 38809Residential Load Calculation SEER /EER Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Capacity continuous ventilation rate in cfms: ML19309016C Heating Loss Manufacturer Lennox Natural Gas Output in Tons: 350 Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 * If awaiting a MPCA permit transfer, provide MPCA proof of transfer submittal e-mail along with this form to erosion@lakevillemn.gov “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) 8/14/24 X PM