HomeMy WebLinkAboutLA226680-18885 Javelin Way-Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND FIRST FLOORTOTAL5,114 SF1,814 SF--GARAGEBASEMENTFLOOR AREA ELEV. DFINISHED-1,062 SF294 SFUNFINISHED200 AMP SERVICEGARAGE RIGHTSECOND FLOOR1,780 SF-SIDEWALK53 SFGARAGE SLABBASEMENT SLABFLATWORK SQUARE FOOTAGE1,673 SF1,034 SF2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGEND1,520 SFWALKOUTPRESERVE OF LAKEVILLELOT 2, BLOCK 318885 JAVELIN WAYMATT MUNZEN & SARAH BARTLETT2ND. ADDITIONHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3-8"E9'-6" OFF LANDINGF5'-0"G6'-6"2018 BUILDING CODE2020 ENERGY CODELAKEVILLE, MN 550441x6 LP TRIM1x6 LP TRIM1'-2"1'-4"ALUMINUM SOFFITCEDARMILL TEXTURELP PANEL WITH3/8" BEAD VULKEM CAULKINGALL 4 SIDES& BACK OF COLUMN1x3 LP TRIM ON FRONT1x2 ON EACH SIDESCALE: 3/4" = 1'-0"COLUMN #12 - CONCRETE PORCH6" CONC. WALLCONCRETE PORCHT.O. CONC.T.O. FTG.T.O. WALLELEV. 109'-7"SIDEWALK 70 SFPorchGarage66666'-0"11'-1"FRAMERS - MAKE SURE THERE IS ICE & WATER SHIELD BEHIND PORCH FRAMERS - 1/2" SHEATHING SHOULD BE FLUSH WITH CONCRETE& DECK LEDGERSCOUNTRY JOE SERIESEXTERIOR FOUNDATION INSULATION10'-3" TALL FOUNDATION WALLSBOLT W/ (1) NUT &1" Ø x 8" ANCHORWASHER @ 60" O.C.OR SIMPSON MAB6 @48" O.C. OR APP'D EQ.6"WALLGALV. ROLLED FLASHING4" CONC. SLAB8"2"262x6 STUD WALL W/BATT INSUL.HIGH DENSITY F.G.1/2" SHEATHING4 MIL. POLY V.B.1/2" GYP. BD OVER266"EL. 110'-3"T.O. 8" CONC.1ST FLOOREL. 110'-8-1/4"1ST FLOORSECTION AT CONCRETE STOOPSCALE: 1-1/2" = 1'-0"A-0218" FLOOR TRUSSEL. 109'-7"T.O. 8" CONC.SCALE: 1-1/2" = 1'-0"DUCT CHASE AT FLOOR TRUSS1A-11'-8"FLOOR TRUSS 3/4" SUB-FLOOR1-1/2" TOP CHORD8" x 8"DUCT1-1/2" SPRAY FOAM (R-10)1-1/2" BOTTOM CHORDFILL 20" FLOOR TRUSS WITHLOOSE FILL FIBERGLASS INSULATION9"= R-23 6" ROUND PIPECOUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701APRIL 19, 20242MAY 9, 20243MAY 23, 20244JULY 9, 2024Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode08/22/2024jnuetzman 8" TRIM BOARD12121'-0"1'-0"8:128:128" TRIM BOARD8" FRIEZE BOARD1'-6"HARDIE LAPBOX OUT GABLE 6"1'-0"1'-6"121212128:12 SHED ROOF8" TRIM BOARD4" EXPOSURE24" OVERHANG8:12 SHED ROOF24" OVERHANGBL2665 - BOTH SIDESBL2665 - BOTH SIDESSHINGLES5'-0"BOX OUT 18" RAKEHARDIE LAP - 4" EXPOSURE6" HARDIE FREEZE BD.BOX OUT GABLE 6"6"X6"X6" BRACKETS-BL24615'-0" BOX OUT 24" OVERHANGPITCH CHANGESHINGLES OVER 15# BUILDINGPAPER 15/32" OSB ROOF SHEATHING(ICE DAM EAVES)FASTEN SHEATHING TO HEADER WITH 8d COMMON ORGALVANIZED BOX NAILS IN 3" GRID PATTERN AS SHOWNON ATTACHED DETAILS.1ST FLRSUBFLOORELEV.110'-814"T.O. FTG.ELEV.100'WALL PLATEELEV.119'-9 3/8"2ND FLRSUBFLOORELEV.120'-10"8'-118"WALL PLATEELEV.128'-1118"SCALE: 1/4" = 1'-0"A-11FRONT ELEVATION - DFOR BRACED WALL REQUIREMENTSBOTH GARAGE PIERSUSE 1/2" OSB SHEATHING10'-3"10'-118"T.O. FND. WALLELEV.110'-3"10'-3" TALL FOUNDATION WALLS4:12BARREL VAULT8:121212COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701APRIL 19, 20242MAY 9, 20243MAY 23, 20244JULY 9, 2024 A-2RIGHT ELEVATION2SCALE: 1/8" = 1'-0"A-21REAR ELEVATIONSCALE: 1/8" = 1'-0"SCALE: 1/8" = 1'-0"LEFT ELEVATION3A-21281281ST FLOORELEV. 110'-8-1/4"2ND FLRELEV.120'-10"9'-11 8"WALL PLATEELEV.119'-9 3/8"T.O. SLABELEV.100'-4"1'-6"1'-0"T.O.WALLELEV.103'-6"26'-0"SCALE: 1/8" = 1'-0"ROOF PLAN - ELEV. DA-2411 ROOF VENTS6:128:128:12 8:12 6:128:12 1'-6"1'-0"1'-6"1'-0"1'-0"1'-0"2'-0" 1'-6"1'-6"12:1212:127'-0"12:1212:1212:1212:1218" MIN.TOP OF PLATEELEV.128'-11-1/8"2'-0"1ST FLOOR9'-118"HARDIELAPGAS F.P.VENT1'-6"12812812:1238'-0"1ST FLOORELEV. 110'-8-1/4"2ND FLRELEV.119'-9-3/8"WALL PLATEELEV.120'-10"TOP OF PLATEELEV.128'-11-1/8"4 / 1212412:121'-6"12:1212:1212:1212:1212:127:127:12 4.7:12124.74.7:124:121264:12 PITCH CHANGE4.7:12COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701APRIL 19, 20242MAY 9, 20243MAY 23, 20244JULY 9, 2024 FURN.MechanicalRoom4" CONC. SLAB308 SFFLR.DRN.SUMP6'-0" X 6'-11" PATIOBEARING WALLT.O. 6" CURBT.O. FOOTINGELEV. 100'-0"T.O. 8" CURBUnexcavated4" CONC. SLABFamily RoomCARPET43'-0"21'-0"46'-0" 25'-10"20'-2" 54'-0" 8'-0"32'-0" LOOKOUT BASEMENT14'-0"18'-0"10'-0"15'-11"7'-9"3'-0"@ 110'-3"BASEMENT PLAN - ELEV. DA-31SCALE: 1/4" = 1'-0"UP 17R@ 7-11/32"9'-1012"30"x60"54"x60" FIXED30"x60"2-2x62-2x625'-10"10"2"7'-0"7'-0"4'-614"3'-1012"3'-1012" SLOPE SLAB FOR DRAINAGE VARIEST.O. SLABT.O. 6" CURBT.O. 2" LEDGET.O. FTG.19'-8"11'-8"A(3) 1-3/4" x 9-1/2" LSL(2) 2x10(2) 2x10DROPPED2'-0"VOID10'-614"(3) 1-3/4" x 11-7/8" LVL6x6 GLUDROPPED64'-0"Stairs38'-0"9'-614"8'-112"10'-0"MIN. FTG. STEP5'-0"NO DRAINTILE AT WALKOUT WALL ONLYT.O. 8" CONC.T.O. FTG.EL. 100'-4"EL. 96'-4"T.O. FTG.T.O. 8" WALLEL. 100'-0"T.O. FTG.32"28"WATERHEATER3x5 PSL30x30x12 FOOTINGSW/ (3) #5 BARS EACH DIRECTIONHELD 3" FROM BOTTOMHOSEBIBHOSEBIBHVACCHASEABOVET.O. 8" WALLT.O. 6" CURB14'-4"(2) 1-3/4" x 11-7/8" LSL4'-6"HALF WALL1A-6EL. 110'-0"EL. 110'-8"EL. 110'-8"EL. 110'-8"EL. 106'-0"9'-0" TALL TYP. MAIN FOUNDATION WALLEL. 96'-4"EL. 109'-0"T.O. 10" WALL110'-3"6'-0" 6'-0"12" CONC. PIERS5'-0" 4'-10" FTGS. TYP.24"x24"LINE OF PORCH ABOVE9'-3"11'-9"12" CONC. PIERS5'-0"1A-7BEAM POCKET4" WIDE x 12 1/2" TALL8"x20" CONCRETEFOOTING - TYPICAL4" DRAINTILE ATFOOTINGS ON EACHWALL AS MARKED ALLOW FOR SEWER24" VOID TO5,000 LB. FOOTINGSTRENGTH MIX2" BRICK LEDGEEL. 110'-0"36"x36"x12" FTG. PADSCDSFIRE RESISTANT FLOOR SYSTEMOR 1/2" GYPSUM WALL BOARDWITH 80 SQ. FEET UNPROTECTED18" FLOOR TRUSSESSEE TRUSS SPECS T.O. 8" WALLT.O. FTG.T.O. 6" CURBEL. 110'-8"EL. 105'-0"T.O. FTG.EL. 110'-0"6" CURB ON TOP OFFOOTINGS AT INTERIORBEARING WALLS (TYPICAL)TOP OF CURB FLUSH WITHTOP OF BASEMENT SLAB11'-8"2-2x62-2x 6 (2) 2x10A36x60 SH36x60 SH36x60 SH42" VAN.36"18" FLOOR TRUSSES SEE TRUSS SPECS 7'-0"60x42 SLIDER8'-912"16'-0"9'-0"ABedroom #50'-4" CONC. SLAB(2) 9-1/2 LSLSSCD36" 18" FLOOR TRUSSESSEE TRUSS SPECS 10"64'-0"1'-812"1'-812"8'-3"1'-812"1'-812"16'-3"1'-812"8'-3"1'-812"48x3430"30"7'-212"3'-812"5'-312"7'-434"7'-912"18'-0"Unexcavated4" CONC. SLAB6'-612"3'-312"40" C.O.LLBathC.T.36 SF. FLR.WETBAR R/I2'-434"5"LOOKOUT BASEMENT10"10"T.O. 10" WALLEL. 110'-3"T.O. FTG.EL. 100'-0"T.O. 8" WALLEL. 110'-3"T.O. FTG.EL. 100'-0"2" BRICK LEDGE FORCONCRETE STOOP @ 110'-3"T.O. WALLEL. 109'-7"T.O. 8" CONC.T.O. FTG.EL. 103'-6"EL. 100'-0"T.O. 8" CONC.T.O. FTG.EL. 103'-6"EL. 100'-0"110'-0"110'-3"T.O. 6" CURBT.O. FTG.EL. 110'-3"EL. 100'-0"T.O. 6" CURBEL. 103'-6"2 TIMMERS3 TIMMERS8"11'-4"APPROX. LOCATIONOF DRAFT STOP5'-0"18" LVL(2) 2x102x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDFINISHED ROOM SIZESBEDROOM #5 & WIC - CONC.MECHANICALLL BATH - C.T.STAIRS - CARPETTOTAL380 SF308 SF74 SF83 SF1,814 SFFAMILY ROOM - CARPET969 SFHEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701APRIL 19, 20242MAY 9, 20243MAY 23, 20244JULY 9, 2024Shearwall ShearwallOnly One Strap/Holdown required atcorner where shearwalls meet.92.63.5UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. 6 6 30" 30" 36" DN 17R UP 18R Stairs 36"28"36" MTL.SERV. DR.Foyer WOOD DW R.C. TWIN REF. (3) 1-3/4" x 14" LVL - FLUSH VAULT 3.5:12 VAULT 3.5:12 14'-114"4'-114"3'-812"2'-51516"7'-934"16'-1"2'-41516"6'-0"2'-41516"2'-9316"38'-0"6'-6"4'-93 4"5'-21 4"5'-0" 9'-101 2"8'-11 2"7'-0"6'-8" 18'-0"13'-8"6'-0"18'-4"14'-0"6'-6"24'-0"20'-0"2'-0"11'-33 4"10'-21 4" 2-Story Great Room WOOD 8'-0" x8'-0" O.H. DOOR (2) 2x12 - CONT. PORTAL FRAME 8'-0" x8'-0" O.H. DOOR (3) 2x12 - CONT. PORTAL FRAME 16'-0" x8'-0" O.H. DOOR (2) 1-3/4" x 11-7/8 LSL - CONT. PORTAL FRAME (+96") 63" DRYWALL OPENING (2) 1-3/4x 11-7/8" LSL - FLUSH 2-2x62-2x6(2) 2x10 Garage INSULATE COMPLETE ZERO-ENTRY THRESHOLD Pantry WOOD Mudroom C.T. W.I.C. C.T. 9'-3"11'-9" 21'-0"46'-0"13'-11"5'-31 2"2'-03 4"6'-1" 15'-13 4"19'-21 2"8'-13 4" Kitchen WOOD Dining Room WOOD 18'-0" x 14'-0" Screened Porch TREX DECKING10'-0"14'-0"14'-114"6'-0"2'-014"7'-214" 3'-9"PANELACCESSATTIC22x30GAS FIREPLACEBUILT-IN CAB.BUILT-IN CAB.(2) 2x10(2) 2x10 24"x 96"ISLAND TOP SIZE 111"x48"48" FREE-STANDINGRANGE W/ WOOD HOODS (2) 2x10 B36x66 SH R & S R & S36x84 FIXED36x84 FIXED(2) 36x66 SH - MULLED48x78 FIXED - TEMP.E G G B 42x84 FIX Porch CONC. S S CD 36x66 SH 36x66 SH 5'-3"4'-9"64'-0" R & S 28"60x368'-0" C.T. WALLSZERO-ENTRYBedroom #4 WOOD 6'-0" 36" STORM 14'-0" x 6'-0" Grill Deck TREX DECKING Pwdr. Bath WOOD 27 SF. FLR.W.I.C. / Laundry C.T. 83 SF (FLR) 5'-0" LOCKERS 48" DROP ZONE(2) 2x1036x66 SH36x66 SH2-2x6 3'-1034"3'-2"1'-714"7'-7"4'-334"42x84 FIX 42x84 FIX BARREL VAULT 66 66 (2) 1-3/4"x7-1/4" LSL2'-814"Jr. Suite Bath C.T. 46 SF. FLR. (3) 1-3/4"x7-1/4" LSL 30" 30" 6'-0" X 8'-0" PATIO (3) 2x10 30x66 SH30x66 SH11'-53 4" 19'-8"11'-8"11'-8" 36" PKT.36" PKT.2'-0" LINEN CAB. 2'-81 4"5'-01 2"4'-0"8'-91 2" RAILING TO LANDING W/ NEWEL POSTS ISPD 36"1'-10"8'-0"1'-10"1'-10"16'-0"1'-10"1'-10"8'-0"1'-10" 43'-0"2'-0"HVAC R & SB WASHER / DRYERROUGH-IN 36" Hall WOOD 25" SINK W/ 32"BASE CABINET B 4'-6" B BPOT-FILLER18" DEEP BENCH 24" BEV. FRIDGE (2) 9-1/2 LSL (2) 30x66 SH - MULLED 3'-2"10'-4"2'-2"4'-4"36" S.R.O.13'-6"11-7/8" TJI JOISTSSEE EWP PLAN11-7/8" TJI JOISTSSEE EWP PLAN11-7/8" TJI JOISTSSEE EWP PLAN(2) 2x10 2 TRIMMERS (2) 2x10(2) 2x10(3) 11-7/8" LSL (4) 20" LVLGIRDER TRUSS6x8 GLU3- 2 x 6 (3) 1-3/4x 14" LVL6x6 GLU (2) 2x1011-7/8" LSL3-2x63- 2 x 6 GIRDER TRUSS SEE TALL WALL EWP DETAILS FOR HEADER INFO@ 2-STORY GREAT ROOM1'-914" 6'-11 4"7'-21 4" 3'-91 2"5'-1"4'-312"7'-358"3'-0" Study CARPET 15'-5"9'-1"1'-1034"2'-314"(2) 11-7/8" LSL - FLUSH 3- 2 x 6 GIRDER TRUSS3-2x6 (1) 9-1/2 LSL 3-2x65-2x6 3-2x6 3- 2 x 6 2x4 INTERIOR WALLS 2x6 INTERIOR WALLS SHEATHING - INSULATED CONCRETE WALLS BRICK / BRICK LEDGE 2x6 EXTERIOR WALL WITH 1/2" FUTURE FINISH WALL LEGEND FINISHED ROOM SIZES STUDY - CARPET 2-STORY GREAT ROOM - WOOD 144 SF 246 SF W.I.C. / LAUNDRY ROOM - C.T.83 SF KITCHEN/DINE/FOYER - WOOD 519 SF MUD ROOM & W.I.C. - C.T.94 SF BEDROOM #4 - CARPET 190 SF POWDER BATH - WOOD 27 SF HALL - WOOD 48 SF PANTRY - WOOD 30 SF JR. SUITE BATH - C.T.78 SF HEADER HEIGHT SCHEDULE A B C 6'-11-1/4" 8'-0" 7'-6" D E 9'-6" OFF LANDING F 5'-0" 6'-11-3/8" G 13'-0" MIN. TREAD 10" STAIR REQUIREMENTS MAX. RISE 7-3/4" 10"734"MIN. NOSING 3/4" MAX. NOSING 1-1/4" 1-1/4"COUNTRY JOE HOMESYOUNGFIELD HOMES22260 DODD BLVD.LAKEVILLE, MN 55044PHONE (952) 469-4066LLC. #BC6276701 APRIL 19, 2024 2 MAY 9, 2024 3 MAY 23, 2024 4 JULY 9, 2024 SCALE: 1/4" = 1'-0" FIRST FLOOR PLAN A-4 1 BWPs Above BWPs Above BWPs Above BWPs Above BWPs Above BWPs Above FAN Temper glass within 60" of bottom stair tread. BWPs Above Verify loads with girder truss specs, may require removal of top plates at bearing due to crushing. -Min. 15" clearance to any obstruction from center of W.C., 24" in front(typ).PROVIDE THE FOLLOWING TALL WALL BRACING REQUIREMENTS:·TALL WOOD WALL FRAMING DESIGNED BY THE SUPPLIER FOR GRAVITY ANDOUT-OF-PLANE WIND LOADS w/ STUD SPACING NOT TO EXCEED 16" O.C.· 716" OR THICKER PLYWOOD/OSB EXTERIOR SHEATHING FASTENED TO STUDSw/ 8d NAILS @ 6" O.C. AT PANEL EDGES & @ 12" O.C. AT INTERIOR SUPPORTS·TOP OF WALL CONNECTIONS SHOWN FOR BRACED WALL PANELS ALONG FULLLENGTH OF GREAT ROOM & STAIR WALLS·BOTTOM OF WALL CONNECTIONS SHOWN FOR BRACED WALL PANELS ALONGFULL LENGTH OF GREAT ROOM WALLS·FASTEN LAPPED WALL TOP PLATES TOGETHER w/ (4) 3" LONG SIMPSON SDWSTIMBER SCREWS IN ADDITION TO NAILS ALONG FULL LENGTH OF GREAT ROOM& STAIR WALLS & MIN. SIX FEET BEYOND INTO PRIMARY BATH & BEDROOM 2ShearwallShearwall Only One Strap/Holdown required at corner where shearwalls meet. 8 5.5 5.5 2.7 6 6 6 PFH PFHPFHPFH 5.5 9 3 6 6 6 6 4'-0"4'-8"4'-6"4'-6"4'-8"4'-2"4'-0"2'-4"3'-6"3'-0"3'-0"4'-8"4'-6"3'-8"6'-0"9'-0"18'-4"4'-0" 1'-0" ROOF TRUSSES @ 24" O.C.2x10 JOISTS @ 16" O.C.2x10 JOISTS @ 16" O.C.(2) 11-7/8" LVL - CONT.(2) 11-7/8" LVL - CONT.4'-0"DECKING SHOULD BE DOWN4" FROM THE FIRST FLOOR(3) 2x10 16'-0" LEDGER BOARD2x10 DECK JOISTS @ 16" O.C.(2) 2x10 2x10 JOISTS - SOUTHERN YELLOW PINE .40 TREATED 5/4" DECKING 3-2x10 BEAMS SOUTHERN YELLOW PINE - .40 TREATED 6x6 POSTS PONDEROSA PINE - .60 TREATED 9'-0" 9'-2"9'-2" 18'-4"4'-0" 1'-0"14'-0"6'-0"STAIRS TO GRADE(3) 2x10T.O. DECKING 3'-0"312"T.O. RAILING 312"4" 3 RAILING DETAILS DECK SCALE: 1/2" = 1'-0" 4" SPHERE CANNOT PASS WESTBURY RAILING SYSTEM TOP OF 8" CONC. ELEV. 108'-4" ELEV. 109'-6-1/8" 1ST FLOOR 1178"34"BOISE RIM BOARD (EXTERIOR) 1-1/8" OSB RIM BOARD (R-20) 11-7/8" TJI JOISTS 2x10 JOISTS FLASHING W/ DRIP EDGE DTT1Z DECK TENSION TIE DECK LEDGER HANGER4"4 LATERAL LOAD CONNECTION DECK SCALE: 3/4" = 1'-0" BOLT THROUGH BLOCKING @ 16" O.C. @ 16" O.C. #12 - STRUCTURAL 4" LEDGER SCREWS @ 16" O.C. DUPONT TYVEK BUILDING PAPER EXTERIOR SHEATHING ICE & WATER SHEILD DUPONT TYVEK BUILDING PAPER ICE & WATER SHEILD HOLDER REQUIRED TO ANCHOR STRAP OR POST SLOPE TO OF PIER CONCRETE PIER FOOTING 51 2" POST 6x6 DECK SUPPORT 60"1'-0" FLARE BOTTOM OF FOOTING TO A MINIMUM DIAMETER OF 24" CONNECT POST TO FOOTING 5 POST & PIER DETAIL DECK SCALE: 1/2" = 1'-0" & A MINIMUM OF 12" DEEP 2'-0"COUNTRY JOE HOMESYOUNGFIELD HOMES22260 DODD BLVD.LAKEVILLE, MN 55044PHONE (952) 469-4066LLC. #BC6276702 DECK FRAMING / FOOTING PLAN DECK SCALE: 1/4" = 1'-0" 1 PORCH HEADER PLAN DECK SCALE: 1/4" = 1'-0" 1 APRIL 19, 2024 2 MAY 9, 2024 3 MAY 23, 2024 4 JULY 9, 2024 25" SINK W/ 32" BASE CABINETDN 18RBedroom #2CARPETBedroom #3WOOD42"HIGH WALL W/W/WOOD CAPGIRDER TRUSSCDGIRDER TRUSS(2) 2X1030x30(2) 36X60 MULLED(2) 2x10A(2) 36X60 MULLED(2) 2x10AATEMP.SSLoftCARPET17'-10"16'-0"7'-7"15'-5"39'-0"11'-112"6'-6"6'-6"3'-6"3'-6"6'-6"6'-6"13'-0"7'-0"13'-0"33'-0"1'-0" 6'-9"25'-0"19'-0"2-2x6A42x84 FIXSEE TALL WALL2-2x 6 42x84 FIX42x84 FIX7'-1112"9'-1012"58'-0"PrimaryBathC.T.104 SF (FLR)W.I.C.CarpetPANELACCESSATTIC22.5x30LaundryRoomVINYL72 SF (FLR)WD32"28"84" VANITY28" ROD & SHELF ROD & SHELF82x36C.T. WALLS& FLOORS48"x48"FIXED(2) 2X10TEMP.(2) TRIMMERS EA. SIDEVAULT 4:124:12 VAULT36"W.I.C.WOOD28"60" VANITY 36"SCDS36x60 SH(2) 2x10(2) 2x10(2) 2x103'-134"3'-134"8'-234"36x24 - FIX36x24 - FIX12'-2"7'-214"20'-934"19'-414"PrimaryBedroomCARPETROD & SHELF30"30"5'-734"19'-414"4'-4"11'-4"4'-4" 20'-0" 2'-6"8'-0"8'-8" 3'-412" 8'-8" 7'-43 4"3'-912"4'-934" 5'-0" 2'-101 4"4'-23 4"7'-11" 4'-0" 6'-10"7'-512"67x32 OVAL FREE-STANDING54x60 FIX36x60 SHAA2-2x62-2x6S28"ROD & SHELF30"3 0 "MainBathC.T.36 SF (FLR)HallCARPET7'-034"28"LINEN 36"2'-6"3'-714"3'-912"28" - GLHALF WALL W/ GLASSAA36" SRO. 36" SRO5'-138"3- 2 x 6 3-2x63- 2 x 6 3-2x6EWP DETAILSFOR HEADER INFO2x4 INTERIOR WALLS2x6 INTERIOR WALLSSHEATHING - INSULATEDCONCRETE WALLSBRICK / BRICK LEDGE2x6 EXTERIOR WALL WITH 1/2"FUTURE FINISHWALL LEGENDMIN. TREAD 10"STAIR REQUIREMENTSMAX. RISE 7-3/4"10"734"MIN. NOSING 3/4"MAX. NOSING 1-1/4"1-1/4"HEADER HEIGHT SCHEDULEABC6'-11-1/4"8'-0"7'-6"D6'-11-3/8"FINISHED ROOM SIZESMASTER BEDROOMLAUNDRY - VINYLMASTER BATH - VINYL230 SF52 SF114 SFHALLWAY & LINEN148 SFBEDROOM # 2163 SFBEDROOM # 4209 SFBEDROOM # 3181 SFBATH - VINYL79 SFMASTER W.I.C.79 SFTHE TOTALS FOR FLOORING ARE ON FLOOR PLANLOFT130 SFELEVATION A-C - STANDARDCOUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC627670SCALE: 1/4" = 1'-0"SECOND FLOOR PLANA-511APRIL 19, 20242MAY 9, 20243MAY 23, 20244JULY 9, 2024PROVIDE THE FOLLOWING TALL WALL BRACING REQUIREMENTS:·TALL WOOD WALL FRAMING DESIGNED BY THE SUPPLIER FOR GRAVITY ANDOUT-OF-PLANE WIND LOADS w/ STUD SPACING NOT TO EXCEED 16" O.C.· 716" OR THICKER PLYWOOD/OSB EXTERIOR SHEATHING FASTENED TO STUDSw/ 8d NAILS @ 6" O.C. AT PANEL EDGES & @ 12" O.C. AT INTERIOR SUPPORTS·TOP OF WALL CONNECTIONS SHOWN FOR BRACED WALL PANELS ALONG FULLLENGTH OF GREAT ROOM & STAIR WALLS·BOTTOM OF WALL CONNECTIONS SHOWN FOR BRACED WALL PANELS ALONGFULL LENGTH OF GREAT ROOM WALLS·FASTEN LAPPED WALL TOP PLATES TOGETHER w/ (4) 3" LONG SIMPSON SDWSTIMBER SCREWS IN ADDITION TO NAILS ALONG FULL LENGTH OF GREAT ROOM& STAIR WALLS & MIN. SIX FEET BEYOND INTO PRIMARY BATH & BEDROOM 2Temper ifwithin 60"of tub floor-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).Top & BottomConnections2.52.56663.53.53.55564.5 SCALE: 1/4" = 1'-0"BUILDING SECTION - ELEV. DA-618" x 20" CONC. FTG'S4" CONCRETE SLABTYPICAL18" FLOOR TRUSS @ 19.2" O.C.10'-3"T.O. 6" CURBELEV. 110'-8-1/4"BOTTOM OF ALL FOOTINGS TO BE 42" MINIMUMBELOW FINISH GRADE RESTING ON UNDISTURBED SOIL1ST FLRSUBFLOORELEV.110'-8-1/4"9'-5"1'-0"1'-0"10'-414"5'-512"11'-134"8'-118"TYPICAL STAIR CONSTRUCTION NOTES:* 6'-10" MINIMUM HEADROOM* (3) 11-7/8" STAIR STRINGERS W/* 11" TREADS* PROVIDE 36" HIGH HANDRAILS & GUARD RAILS PER CODE.~ MINIMUM TREAD DEPTH 10" - MAX RISE 7-3/4"MINIMUM NOSING 34" MAX. NOSING 1-1/4"StairsStairs5'-078"20" FLOOR TRUSSESBedroom # 3LoftFoyerGarage4" CONCRETE SLAB PITCHEDTOWARDS OVERHEAD DOORS5/8" TYPE X GYP. BRD.ON ALL COMMON WALLS &CEILINGS.MUD ALL JOINTS1/2" SHEATHING - EXT.TYPICAL GARAGE WALL2x6 STUD WALLS @ 16" O.C. W/R-49 ROOF INSULATIONTRUSSES @ 24" O.C.PRE-ENGINEERED ROOFR-49 ROOF INSULATIONTRUSSES @ 24" O.C.PRE-ENGINEERED ROOFBasement11-7/8" TJI JOISTS @ 16" O.C.6'-078"DROP GARAGE WALL 8-1/8"81 8"5,000 LB. FOOTINGSTRENGTH MIX2x8ELEV. 120'-9-3/8"ELEV. 121'-10"TOP OF PLATE2ND FLOORELEV. 110'-8-1/4"1ST FLOORELEV. 129'-11-1/8"2ND FLOOR CLG.10'-3"4'-1034"2x812121'-6"1'-27 8"4'-012"4'-6"MIN. TREAD 10"STAIR REQUIREMENTSMAX. RISE 7-3/4"10"73 4"MIN. NOSING 3/4"MAX. NOSING 1-1/4"1-1/4"COUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701APRIL 19, 20242MAY 9, 20243MAY 23, 20244JULY 9, 2024 BUILDING SECTION1A-6SCALE: 1/4" = 1'-0"INTERIOR & EXTERIOR 4" DIA. PERFORATED DRAIN TILE PIPED TOSUMP BASKET.10'-6" WALLS - (1) 2x6 TOP PLATE 4" CONCRETE SLAB8" x 20" CONC. FTG'SELEV. 100'-0"TOP OF FOOTINGTOP OF 8" CONC.ELEV. 110'-3"1ST FLOOR - 110'-8-1/4"MAINTAIN A MIN. CL.OF 6" FROM GRADETO BOTTOM OF SIDINGWATERPROOFING1) COAT EXTERIOR W/ POLYUREA WATER-8" THICK CONC. WALLS18" FLOOR TRUSSESBLOCKING AT FOUNDATIONWALLS PARALLEL TO FRAMINGSEE DETAIL S-6BPROOFINGDUCT3/4" OSB FLOOR SHEATHING5,000 LB. FOOTINGSTRENGTH MIX2) FOAM W/ POLYURETHANE (R-15)6 MIL POLY SLIP SHEET OVERFOAM PRIOR TO BACKFILLAS REQUIRED PER CITYBOISE RIM BOARD1-1/8" OSB RIM BOARD(R-20)1/2" ANCHOR BOLTSPLATE W/ SILL SEAL INSUL. &PRESSURE TREATED 2x6 SILLSEAL ALL JOINTS, CRACKS, OR OTHEROPENINGS WITH POLYURETHANE CAULKFOR RADON PROTECTIONFIRE RESISTANT FLOOR SYSTEM1/2" GYPSUM WALL BOARD WITH80 SQUARE FEET UNPROTECTED3" EXTERIOR FOAM INSULATION ATLOOKOUT/WALKOUT SIDE WALLS. 2"FOAM AT FULL BASEMENT & 4' FROSTFOOTINGS.GLUED AND NAILED9'-012"RIGID METAL FLASHING INSTALLED BY SIDERPROTECTION TO6" BELOW GRADE1/2" ANCHOR BOLTS@ 6'-0" O.C. (8" EMBED.)3) APPLY ABOVE GRADEFOUNDATION COATING2x6 STUD WALLS @16" O.C. W/ (R-21) FIBERGLASS BATTINSULATION, 4 MIL POLYVAPOR BARRIER & 1/2"GYPSUM BOARD INSIDE 2x6 STUD WALLS @16" O.C. W/ (R-21) FIBERGLASS BATTINSULATION, 4 MIL POLYVAPOR BARRIER & 1/2"GYPSUM BOARD INSIDE 8'-118"ELEV. 120'-9-3/8"ELEV. 121'-10"TOP OF PLATE2ND FLOOR10'-118" 34" 1178"ELEV. 129'-11-1/8"2ND FLOOR CLG.BOISE RIM BOARD1-1/8" OSB RIM BOARD11-7/8" TJI JOISTS @ 16" O.C.OR 1/2" SAG-RESISTANT5/8" TYPE "X" GYP. BD.R-49 ROOF INSULATIONPRE-ENGINEERED ROOFTRUSSES @ 24" O.C.OR 1/2" SAG-RESISTANT5/8" TYPE "X" GYP. BD.3/4" OSB FLOOR SHEATHINGMIN. 6" ENERGY HEAL(R-20)GLUED AND NAILED1/2" EXTERIOR SHEATHINGTYPICAL UNLESS NOTEDOTHERWISE1/2" EXTERIOR SHEATHINGTYPICAL UNLESS NOTEDOTHERWISESHINGLES OVER 15#15/32" OSB ROOF SHEATHINGBUILDING PAPER(ICE DAM EAVESSCALE: 1/4" = 1'-0"PORCH SECTION - ELEV. DA-721'-6"9'-0"COLUMN BEYONDSEE ELEVATIONSAND FLOOR PLAN8'-118"FOYERCOVEREDPORCHMECH.ROOMBEDROOM #2TRUSSES @ 24" O.C.PRE-ENGINEERED ROOF1-0" CANTMATCH GARAGE PLATE HEIGHTWITH TOP OF PORCH BEAM 5'-0"1242'-3"VERIFY: FASCIA TOPLANE OUT WITHGARAGE FASCIA4 7 16"1'-6"12" MIN.SIMPSON MSTC28 STRAP W/MIN (14) 10d NAILS EACH INTOI-JOIST/RIM @ DOUBLE STUDS.BOISE RIM BOARD1-1/8" OSB RIM BOARD2X6 STUDS @ 16" O.C.PROVIDE 3/4" PLYWOOD GUSSETONE SIDE OF I-JOIST W/ 16d NAILS@ 3" OC.C TO TOP @ BOTTOM CHORDSPROVIDE BLOCKING BETWEENJOISTS AS REQUIRED. 2X6 WALL STUD BELOWSIMPSON HTW24 TWIST STRAPW/ (12) 10d NAILS AT EACH ENDOF CANT.BLOCKING AT END WHERETWIST STRAP IS LOCATED1'-0"DETAIL @ CANTILEVER3SCALE: 1/2" = 1'-0"A-7SHEATH WITH 1/2" OSBCOUNTRY JOE HOMES YOUNGFIELD HOMES 22260 DODD BLVD. LAKEVILLE, MN 55044 PHONE (952) 469-4066 LLC. #BC6276701APRIL 19, 20242MAY 9, 20243MAY 23, 20244JULY 9, 2024 ProductsPlotID Length ProductPlies Net QtyM132' 0" 1 3/4" x 18" 2.0E Microllam LVL 1 1M2-314' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 3 33-2x10 Trtd. 20' 0" 2 x 10 SPF No.1/No.23 33-2x10 Trtd. 14' 0" 2 x 10 SPF No.1/No.23 32-2x10 Trtd. 14' 0" 2 x 10 SPF No.1/No.22 2BBO1-2 6' 0" 2 x 10 SPF No.1/No.22 2Wall FramingPlotID Length ProductPlies Net QtyTSHd1-3 12' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 3 3TSHd2-2 6' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 2 2BBOHd1-2 10' 0" 2 x 10 SPF No.1/No.22 2BBOHd2-2 8' 0" 2 x 10 SPF No.1/No.22 2BBOHd3-2 4' 0" 2 x 10 SPF No.1/No.22 2TSHd1-3 BBOHd1-2 BBOHd2-2TSHd2-2M2-3BBO1-2 BBOHd3-23-2x10 Trtd.3-2x10 Trtd.2-2x10 Trtd.M1← Floor Trusses →3 Trimmers2 Trimmers6x6 Glulam6x6 GlulamCustomer:Job Name:Address/Lot:Youngfield HomesMunzen & Bartlett18885 Javelin WayCity, State:Lakeville, MNPlan/Model #:Watkins D CustomJob Number:2441Lyman Lumber Company18900 West 78th StPO Box 130Chanhassen, MN(952) 470-4800Sheet:1A complete Javelin™ framing plan requires the Framer's Pocket GuideSee the Framer's Pocket Guide for Product Trademark InformationDrawn By:Jeff D.Drawn Date:7/2/24Revised By:Jeff D.Revision Date:8/8/24Revision #:4SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ON THIS DRAWING. LYMAN LUMBER COMPANY IS ONLY RESPONSIBLE FOR INDIVIDUAL MEMBER DESIGN,BASED UPON THE ASSUMED VERTICAL LOADS. BUILDER IS RESPONSIBLE FOROVERALL DESIGN OF THE STRUCTURE AND IT IS STRONGLY RECOMMENDEDTHAT ALL DRAWINGS AND CALCULATIONS BE REVIEWED BY THEENGINEER OF RECORD FOR THIS PARTICULAR PROJECT.Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut LinesRim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, iLevel®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, TJ® and Trus Joist® are registered trademarks of Weyerhaeuser NR. © 2012 Weyerhaeuser NR Company. All rights reserved.Header Spans:Up to 4'-11" = 1 Trimmer 5'-0" and Bigger = 2 Trimmers*** Unless Noted Otherwise *** Start Joist Layout Here. 16" o/cFraming Connector SummaryPlotID Qty Manuf Product Face Nails Top Nails Member Nails Web StiffH1 1 Simpson HU410 14- 10dx1.5 - 6- 10d NoH2 1 Simpson HGUS5.50/8 36- 10d - 12- 10d NoH3 1 Simpson HUCQ1.81/9-SDS 8- SDS25134 - 4- SDS25134 NoH4 6 User IUS2.06/11.88 Not RequiredH5 1 Simpson HU2.1/11 16- 10dx1.5 - 6- 10dx1.5 YesH6 1 Simpson HHUS410 30- 16d - 10- 16d NoH7 11 Simpson IUS2.06/11.88 10- 10dx1.5 - 2- Strong-Grip NoProductsPlotID Length Product Plies Net QtyF38' 38' 0" 11 7/8" TJI 210 joist 1 1F26' 26' 0" 11 7/8" TJI 210 joist 1 1F24' 24' 0" 11 7/8" TJI 210 joist 1 2F22' 22' 0" 11 7/8" TJI 210 joist 1 4F20' 20' 0" 11 7/8" TJI 210 joist 1 30F16' 16' 0" 11 7/8" TJI 210 joist 1 7F14' 14' 0" 11 7/8" TJI 210 joist 1 1TJI Blocking 6' 7 3/8" 11 7/8" TJI 210 joist 1 1M1-4 26' 0" 1 3/4" x 20" 2.0E Microllam LVL 4 4M2-3 20' 0" 1 3/4" x 14" 2.0E Microllam LVL 3 3M3-3 14' 0" 1 3/4" x 14" 2.0E Microllam LVL 3 3M4-2 16' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 2 2M5-2 6' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 2 2TS1-2 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 22TS2-2 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 24TS3 8' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 2TS4 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1TS5-2 4' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2TS6-3 14' 0" 1 3/4" x 7 1/4" 1.55E TimberStrand LSL 3 3TS7-2 10' 0" 1 3/4" x 7 1/4" 1.55E TimberStrand LSL 2 4Rim 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 82x8 Flat Blocking 11' 5 7/8" 2x8 blocking (11 7/8" joist depth) 1 1BBO1-3 14' 0" 2 x 12 SPF No.1/No.2 3 3BBO2-2 12' 0" 2 x 12 SPF No.1/No.2 2 2Solid Blocking 2' 0" 5 1/2" x 11 7/8" CS Block 1 3Wall FramingPlotID Length Product Plies Net QtyTSHd1-3 14' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL1 2TSHd2-2 6' 0" 1 3/4" x 9 1/2" 1.55E TimberStrand LSL 22BBOHd1-2 10' 0" 2 x 10 SPF No.1/No.2 2 2BBOHd3-3 8' 0" 2 x 10 SPF No.1/No.2 3 3BBOHd2-2 8' 0" 2 x 10 SPF No.1/No.2 2 4BBOHd4-2 6' 0" 2 x 10 SPF No.1/No.2 2 2BBOHd5-2 4' 0" 2 x 10 SPF No.1/No.2 2 10CSCSPB1PB1PB1PB1PB1PB1TS2-2Girder TrussGirder TrussM2-3M3-3TS3F20'RimRimRimRimRimRim2x8 Flat BlockingTS4BBOHd4-2M5-2M4-2BBOHd1-2BBOHd2-2Solid BlockingSolid BlockingSolid BlockingTS7-2TS7-2TS6-3RimBBO2-2TS1-2BBO1-3M1-4Rim2x8 Flat BlockingBBOHd3-3 BBOHd5-2BBOHd5-2BBOHd5-2BBOHd2-2TSHd2-2BBOHd5-2BBOHd5-21' 5"1' 3"1' 4"TJI BlockingTS2-2RimF20'TS3F38'Option #2:2x_ strapping installed at 13joist-span locations using two212" screws per joist, typicalOption #1:TJI® joist blocking with endblocks installed at 13 joist-spanlocations usingtwo 8d (0.113" x 212")nails or212" screws,typicalPB1Option #3:Directly applied ceilingWhen specified on the layout, one ofthe bracing options above is requiredApply subflooradhesive to allcontact surfaces8' max.13 joist span11 3/4"Girder TrussRimF26'F14'Rim1' 0" 11 7/16"TS5-21' 8"1' 4"H6H3H7H5H2H1H4H4H4H4H4H4TSHd1-3F16'16" O.C.F22'16" O.C.F24'16" O.C.F20'16" O.C.H73-2x63-2x63-2x63-2x63-2x63-2x65-2x64-2x62 Trimmers2 Trimmers← Floor Trusses →← Roof Trusses →2 TrimmersTall WallsSee Forte Calcs for SpecsInstall these H4hangers upside down4-2x63-2x63-2x66x8 Glulam3-2x63-2x6Customer:Job Name:Address/Lot:Youngfield HomesMunzen & Bartlett18885 Javelin WayCity, State:Lakeville, MNPlan/Model #:Watkins D CustomJob Number:2441Lyman Lumber Company18900 West 78th StPO Box 130Chanhassen, MN(952) 470-4800Sheet:2A complete Javelin™ framing plan requires the Framer's Pocket GuideSee the Framer's Pocket Guide for Product Trademark InformationDrawn By:Jeff D.Drawn Date:7/2/24Revised By:Jeff D.Revision Date:8/8/24Revision #:4SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ON THIS DRAWING. LYMAN LUMBER COMPANY IS ONLY RESPONSIBLE FOR INDIVIDUAL MEMBER DESIGN,BASED UPON THE ASSUMED VERTICAL LOADS. BUILDER IS RESPONSIBLE FOROVERALL DESIGN OF THE STRUCTURE AND IT IS STRONGLY RECOMMENDEDTHAT ALL DRAWINGS AND CALCULATIONS BE REVIEWED BY THEENGINEER OF RECORD FOR THIS PARTICULAR PROJECT.Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut LinesRim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, iLevel®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, TJ® and Trus Joist® are registered trademarks of Weyerhaeuser NR. © 2012 Weyerhaeuser NR Company. All rights reserved.Header Spans:Up to 4'-11" = 1 Trimmer5'-0" and Bigger = 2 Trimmers*** Unless Noted Otherwise *** Wall FramingPlotID Length Product Plies Net QtyBBOHd1-2 12' 0" 2 x 10 SPF No.1/No.2 2 2BBOHd2-2 8' 0" 2 x 10 SPF No.1/No.2 2 4BBOHd3-2 6' 0" 2 x 10 SPF No.1/No.2 2 2BBOHd4-2 4' 0" 2 x 10 SPF No.1/No.2 2 6Girder TrussGirder TrussBBOHd2-2 BBOHd2-2BBOHd4-2BBOHd3-2BBOHd1-2BBOHd4-2BBOHd4-23-2x63-2x63-2x63-2x62 TrimmersTall WallsSee Forte Calcs for SpecsCustomer:Job Name:Address/Lot:Youngfield HomesMunzen & Bartlett18885 Javelin WayCity, State:Lakeville, MNPlan/Model #:Watkins D CustomJob Number:2441Lyman Lumber Company18900 West 78th StPO Box 130Chanhassen, MN(952) 470-4800Sheet:3A complete Javelin™ framing plan requires the Framer's Pocket GuideSee the Framer's Pocket Guide for Product Trademark InformationDrawn By:Jeff D.Drawn Date:7/2/24Revised By:Jeff D.Revision Date:8/8/24Revision #:4SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ON THIS DRAWING. LYMAN LUMBER COMPANY IS ONLY RESPONSIBLE FOR INDIVIDUAL MEMBER DESIGN,BASED UPON THE ASSUMED VERTICAL LOADS. BUILDER IS RESPONSIBLE FOROVERALL DESIGN OF THE STRUCTURE AND IT IS STRONGLY RECOMMENDEDTHAT ALL DRAWINGS AND CALCULATIONS BE REVIEWED BY THEENGINEER OF RECORD FOR THIS PARTICULAR PROJECT.Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut LinesRim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, iLevel®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI ®, TJ® and Trus Joist® are registered trademarks of Weyerhaeuser NR. © 2012 Weyerhaeuser NR Company. All rights reserved.Header Spans:Up to 4'-11" = 1 Trimmer5'-0" and Bigger = 2 Trimmers*** Unless Noted Otherwise *** PARTIAL LOWER LEVEL HOUSE PLANSHOWN FOR LOCATION REFERENCE ONLY1S1REFERENCE PLAN(2.5-FT)(2.5-FT)(6-FT)(4-FT)ONE-SIDED(4-FT) ONE-SIDED(3.5-FT)(3.5-FT)(3.5-FT)(4-FT)(4-FT)(4-FT)BRACED WALL LINE BRACED WALL LINE BRACED WALL LINE BRACEDWALL LINEBRACEDWALL LINEBRACEDWALL LINE(6-FT)(3-FT)(4-FT)(5.5-FT) (8-FT) (6-FT) ONE-SIDED (9-FT)(6-FT)ONE-SIDED(4-FT)(4-FT)(4-FT)(5-FT)(5-FT) (6-FT)(6-FT)(6-FT)(6-FT)(4.5-FT)(4-FT)BRACED WALL LINE (6-FT)(6-FT)(6-FT)(2.7-FT)(5.5-FT)(5.5-FT)BRACED WALL LINE BRACED WALL LINE BRACED WALL LINE BRACED WALL LINE BRACEDWALL LINEBRACEDWALL LINEBRACEDWALL LINE(2.6-FT)(3.5-FT)(4-FT)(4-FT)(4-FT)(9-FT)BRACED WALL LINEBRACEDWALL LINENOTESEE 4/S2 FOR REQUIREMENTS WITH A BRACEDWALL PANEL LOCATED ABOVE A CANTILEVER.MAIN LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY2S1REFERENCE PLANUPPER LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY3S1REFERENCE PLANTHIS SHEET/S REPRESENTS A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRERESIDENTIAL STRUCTURE. THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WINDRESISTING ELEMENT THAT IS REQUIRED FOR THE HANSON GROUP'S DESIGN IS SHOWN ON THE STRUCTURALDRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TOROOF TRUSSES ABOVE, TO JOISTS/TRUSSES/BLOCKING ABOVE, AND TOJOISTS/TRUSSES/BLOCKING BELOW. THESE PANELS ARE NOT NECESSARILYREQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR JOISTS)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.EXTERIOR NON-BEARING WALLFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUMSHEATHING BOTH FACES WITH EITHER FASTENER OPTIONLISTED IN NOTE 3, SPACED AT 4" O.C. PROVIDE INCREASEDFASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TOBE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)INDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ONEXTERIOR FACE IN ACCORDANCE w/ NOTE 2. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.(MIN. LENGTH)w/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIPNAIL BOTTOM PLATETO RIM/JOIST/BLOCKING w/ (3) 16dNAILS EVERY 16"NAIL BOTTOM PLATETO RIBBON BRACE /TRUSS w/ (3) 16dNAILS EVERY 16"NAIL EACH JOIST TOTOP PLATES w/ (3)0.131"Ø x 3" NAILS2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHNAIL EACH TRUSS TOTOP PLATES w/ (3)0.131"Ø x 3" TOENAILSROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"NAIL RIM TOPPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO LADDERTRUSS w/ (3) 16dNAILS EVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/0.131"Ø x 3"NAILS @ 6" O.C.INTERIOR WALLPERPENDICULAR TO FRAMINGINTERIOR WALLPARALLEL w/ FRAMING2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN JOISTSNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH JOIST TO TOPPLATE w/ (3) 0.131"Ø x 3" NAILSNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN TRUSSESNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH TRUSS TO TOP PLATEw/ (3) 0.131"Ø x 3" TOENAILSPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE JOIST DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSS DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.MATERIALSWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLSL:134" WIDTH - 1.55E OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLOADSROOF SNOW LOAD: 35 PSFROOF DEAD LOAD: 15 PSFFLOOR LIVE LOAD: 40 PSFFLOOR DEAD LOAD: 15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODE2020 MINNESOTA RESIDENTIAL CODESCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM FOR A SINGLE-FAMILY RESIDENCE. CONSTRUCTION ISTO BE IN ACCORDANCE WITH THIS DOCUMENT, STANDARD INDUSTRY PRACTICE, AND THE CODE.NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO CONSTRUCTION DOCUMENTS FOR MORE INFORMATION.2.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICHMEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x4/2x6 STUDS SPACED BY SUPPLIER NOT TO EXCEED 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.3.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. ORTYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)4.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS.5.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIP OR EQUIVALENT AND (4) 0.131"Ø x 3"TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.6.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12) 0.131"Ø x 3" INLAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3" FACE NAILS.7.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).8.TALL WOOD WALL FRAMING IS TO BE DESIGNED BY THE SUPPLIER FOR GRAVITY AND OUT-OF-PLANE WIND LOADS.9.THE ENTRY PORCH, SCREEN PORCH, AND DECK ARE CONSIDERED TO BE PRIMARILY OPEN, NON-ESSENTIAL PORTIONSOF THE STRUCTURE AND ARE EXCLUDED FROM THE OVERALL MAIN WINDFORCE SYSTEM OF THE HOME. PROVIDECODE REQUIRED UPLIFT CONNECTIONS AT ALL POSTS AND TENSION CONNECTIONS AT LEDGERS.COPYRIGHT HANSON GROUP, LLC 2024©DescriptionDateRevisionJuly 15, 2024Project Number:Date:4.276S11Sheets: of2Youngfield Homes, Inc.22260 Dodd BoulevardLakeville, MN 55044Munzen & Bartlett Residence18885 Javelin WayLakeville, MNPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.Print Name:Signed: License Number:Ryan Mack7-15-2446673Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.5851 Cedar Lake RoadSuite 202St. Louis Park, MN 55416Tel 612-708-3572www.hansongroupmn.comNOTESEE 4/S2 FOR REQUIREMENTS WITH A BRACEDWALL PANEL LOCATED ABOVE A CANTILEVER.CONSTRUCTSHEARWALL ASSHOWN IN 2/S2CONSTRUCTPORTAL FRAMEAS SHOWN IN 1/S2CONSTRUCTPORTAL FRAMEAS SHOWN IN 1/S2CONSTRUCTSHEARWALL ASSHOWN IN 2/S2 SIM.ONLY ONESTRAP/HOLDOWNREQUIRED ATCORNER WHERESHEARWALLS MEETCONSTRUCTSHEARWALL ASSHOWN IN 2/S2CONSTRUCTSHEARWALL ASSHOWN IN 2/S2 SIM.ONLY ONESTRAP/HOLDOWNREQUIRED ATCORNER WHERESHEARWALLS MEETPROVIDE TOP & BOTTOMOF WALL CONNECTIONSSHOWN FOR BRACED WALLPANELS ALONG INDICATEDPORTION OF WALLPROVIDE THE FOLLOWING TALL WALL BRACING REQUIREMENTS:·TALL WOOD WALL FRAMING DESIGNED BY THE SUPPLIER FOR GRAVITY ANDOUT-OF-PLANE WIND LOADS w/ STUD SPACING NOT TO EXCEED 16" O.C.· 716" OR THICKER PLYWOOD/OSB EXTERIOR SHEATHING FASTENED TO STUDSw/ 8d NAILS @ 6" O.C. AT PANEL EDGES & @ 12" O.C. AT INTERIOR SUPPORTS·TOP OF WALL CONNECTIONS SHOWN FOR BRACED WALL PANELS ALONG FULLLENGTH OF GREAT ROOM & STAIR WALLS·BOTTOM OF WALL CONNECTIONS SHOWN FOR BRACED WALL PANELS ALONGFULL LENGTH OF GREAT ROOM WALLS·FASTEN LAPPED WALL TOP PLATES TOGETHER w/ (4) 3" LONG SIMPSON SDWSTIMBER SCREWS IN ADDITION TO NAILS ALONG FULL LENGTH OF GREAT ROOM& STAIR WALLS & MIN. SIX FEET BEYOND INTO PRIMARY BATH & BEDROOM 2SEE 3/S1 FORTALL WALLBRACINGREQUIREMENTS S2FRAMING DETAILGARAGE FRONT PORTAL FRAME1NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.8'-3"±9'-5"±FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT STUD EACH END OF HEADERLOCATE PANEL JOINT WITHIN 2'-0" FROMCENTER OF WALL HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x6 BEARING STUDS MIN.(VERIFY w/ SUPPLIER)PROVIDE 2x6 INFILL WALLABOVE HEADER AS REQ'DSIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 3/S2 FOR ALTERNATIVE OPTION)FOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADER58" Ø ANCHOR BOLT (7" MIN. EMBED)w/ 2" x 2" x 316" PLATE WASHERNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/ (2)ROWS 8d NAILS @ 3" O.C. STAGGERED & TOPLATES / BLOCKING @ 3" O.C.)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.LARGE HATCH AREA INDICATES 716" OR THICKERPLYWOOD OR OSB SHEATHING APPLIED TO EXTERIORSIDE OF STUDS w/ STANDARD 6"/12" NAILINGFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELS1'-812"±CONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN.312" WIDTH & MIN.1114" DEPTH REQ'D)1'-812"±PROVIDE DOUBLE STUDS ATEACH END OF SHEARWALL(MAY USE BEARING/KINGSTUDS AS REQ'D)HATCHED AREA INDICATES 716" ORTHICKER PLYWOOD/OSB EXTERIORSHEATHING FASTENED TO STUDS w/8d NAILS @ 4" O.C. AT PANEL EDGES& @ 12" O.C. AT INTERIOR SUPPORTSFASTEN FRAMINGABOVE AS SHOWN FORBRACED WALL PANELSHEADER & BEARING/KINGSTUDS AT SIDES OFOPENINGS BY SUPPLIERTYPICAL 2x6 STUDS @ 16" O.C.FASTEN BOTTOM PLATEw/ (3) 16d NAILS EVERY 16"SIMPSON MSTC52 STRAPSCENTERED ON FLOOR SYSTEMAT LOCATIONS SHOWN(PROVIDE 2x BLOCKING INFLOOR SPACE AS REQ'D)PROVIDE DOUBLE STUDS ATEACH END OF SHEARWALL(MAY USE BEARING/KINGSTUDS AS REQ'D)HATCHED AREA INDICATES 716" ORTHICKER PLYWOOD/OSB EXTERIORSHEATHING FASTENED TO STUDS w/8d NAILS @ 4" O.C. AT PANEL EDGES& @ 12" O.C. AT INTERIOR SUPPORTSFASTEN FRAMINGABOVE AS SHOWN FORBRACED WALL PANELSHEADER & BEARING/KINGSTUDS AT SIDES OFOPENINGS BY SUPPLIERTYPICAL 2x6 STUDS @ 16" O.C.SIMPSON STHD14EMBEDDED HOLDOWNANCHOR AT LOCATIONSSHOWN (REFER TO 3/S2FOR ALTERNATIVE OPTION)SILL PLATE ATTACHED TOFOUNDATION w/ ANCHORBOLTS PER CODENOTES·INFO APPLIES SYMMETRICALLY ACROSSDETAIL UNLESS NOTED/SHOWN OTHERWISE.·QUANTITY AND SIZE OF OPENINGS VARY ATSIMILAR SHEARWALL LOCATIONS.2S2FRAMING DETAILSTACKED PERFORATEDSHEARWALLS SECTION 4S2AT BRACED WALL PANELS ABOVECANTILEVERED FLOOR FRAMINGNOTESECTION ONLY APPLIES WHEN BRACED WALLPANELS OR SHEARWALLS ARE LOCATED ABOVEFLOOR CANTILEVER. SEE PLAN FOR APPLICABILITY.COPYRIGHT HANSON GROUP, LLC 2024©DescriptionDateRevisionProject Number:Date:4.276S22Sheets: of2Youngfield Homes, Inc.22260 Dodd BoulevardLakeville, MN 55044Print Name:Signed: License Number:Ryan Mack46673Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.5851 Cedar Lake RoadSuite 202St. Louis Park, MN 55416Tel 612-708-3572www.hansongroupmn.comCONCRETEFOUNDATIONBELOWSIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWN w/12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHORPOST-INSTALLED HOLDOWN OPTION3S2FRAMING DETAILBRACED WALL PANELFASTEN BOTTOM PLATE TOJOIST/BLOCKING w/ (3) 16dNAILS EVERY 16" O.C.CANTILEVERED FLOORJOIST BY SUPPLIERFRAMEWALL / BRACEDWALL PANEL BELOWBLOCKING BETWEEN JOISTS AS FOLLOWS:·FLAT 2x4 TOP & BOTTOM OR JOISTMATERIAL OR SAWN BLOCKING·34" PLYWOOD SHEET NAILED TO 2x4's w/(8) 8d NAILS TOP & BOTTOM·CIRCULAR HOLE UP TO 8"Ø MAY BE CUTINTO CENTER OF PLYWOODNAIL FLOOR SHEATHING TOBLOCKING w/ 8d NAILS @ 6" O.C.FASTEN BOTTOM 2x4 w/ (3) 16dNAILS EVERY 16" O.C.July 15, 2024Munzen & Bartlett Residence18885 Javelin WayLakeville, MN7-15-24 Print Name: Signed: Nick Hanson I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. License Number:1-1-24 46665Date: SCOPE OF DRAWINGS: THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED AND CERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESE DRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P. CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANT TO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR. THESE DRAWINGS EXPIRE ON DECEMBER 31, 2024. 2024 FOUNDATION GUIDE: DRAWING INDEX: SCOPE, INDEX, & CERTIFICATION S0 USE GUIDELINES AND MATERIALS S1 GENERAL NOTES S2 STEP FOOTING DETAIL S3 WALKOUT WALL DETAIL S4 LOOKOUT/KNEE WALL DETAIL S5 EXTERIOR LOW GRADE FOUNDATION DETAIL S6 BASEMENT WALL DETAIL S7 BASEMENT WALL VERTICAL REINFORCING TABLE S8 BRICK LEDGE DETAILS S9 FLOOR MEMBER BEARING DETAIL AND CONNECTION TABLE S10 BASEMENT WALL ANCHOR SPACING TABLE S11 NON-BEARING WALL JOIST BLOCKING DETAIL S12 NON-BEARING WALL TRUSS BLOCKING DETAIL S13 WINDOW WELL DETAIL S14 STEPPING DOWN WALL WITH GRADE S15 COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 150 4.001 January 1, 2024 S0 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS SCOPE, INDEX, & CERTIFICATION Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake RoadSuite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com    &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 DRAWING USE GUIDELINES AND LIMITATIONS THE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THIS PACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE. THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THE PROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS. THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT IN ACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEW AND INSPECTIONS. LIMITATIONS 1. BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOP OF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT). 2. STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT. 3. OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITE SPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED. 4. STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST OR STRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED. 5. EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS. 6. ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURAL ENGINEERING DOCUMENTS. COLD WEATHER GUIDELINES: 1. THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILL ADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONAL CEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED AT TEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F. 2. DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHEN POSSIBLE. 3. DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS IS RECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR IN CONTACT WITH FROZEN MATERIALS. 4. REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE. 5. BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLS WHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALL WHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F. **THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHER REQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE. MATERIALS CONCRETE WALLS: F'c = 3000 PSI @ 28 DAYS MIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIER CONCRETE FOOTINGS: F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDES A WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE. AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX. REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40 #5+ BARS - ASTM A615 GRADE 60 TREATED SILL PLATE: SYP GRADE #2 OR BETTER ALLOWABLE SOIL BEARING PRESSURE 1,500 PSF MINIMUM EQUIVALENT REBAR TABLE FOR BUNDLED HORIZONTAL BARS (2)#4 = (1)#6 (3)#4 = (2)#5 (3)#5 = (2)#6 COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 151 4.001 January 1, 2024 S1 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS DRAWING LIMITATIONS & MATERIALS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake RoadSuite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com & T G Y U % Q P E T G V G + P E 21$QZ 5JCMQRGG/0 GENERAL NOTES 1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVE STRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLY SUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESS ADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 2. STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS. 3. 1 12" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT AND FROST WALLS. 4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIP FOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE. 5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS. 6. SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEET UNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED. 7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, AND INSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTED OTHERWISE. 8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALL THICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS. 9. REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2" OFCENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BAR DIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET. 10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS. HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVER IS ACHIEVED ON ALL SIDES. 11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS. 12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN. VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS. 13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINOR FORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS. 14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONS ARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALL CORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS IN LENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELS MAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHT FOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOAD TRANSFER OVER A SILL PLATE OVERHANG CONDITION. 15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1. 16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS. 17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS. 18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL AND DIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICAL REINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED, BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDING IS ACHIEVED. 19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING. MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS. 20.THESE DRAWINGS ARE INTENDED TO BE A LIMITED COMPONENT DESIGN TO RESIST LATERAL SOIL PRESSURES FOR SINGLE FAMILY RESIDENCES. VERTICAL LOADS AND FOOTING DESIGNS ARE TO BE THE RESPONSIBILITY OF THE BUILDING DESIGNER. NO SUPPLEMENTAL ENGINEERING OR COMPONENT DESIGN FOR THE FOUNDATION SYSTEM SHALL BE INCLUDED WITH THIS PACKET WITHOUT THE PRIOR REVIEW AND CONSENT OF THE HANSON GROUP. COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 152 4.001 January 1, 2024 S2 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS GENERAL NOTES Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com 21$QZ 5JCMQRGG/0 (2) #4 HORIZONTAL BARS BOTH TOP & BOTTOM EXTENDED AT LEAST 24" BEYOND EACH END OF STEP STABLE BANK HIGH FOOTING MAY BE EXTENDED PROVIDED BARS ARE PLACED AS SHOWN HORIZ. BARS TOP & BOTTOM 6" MIN THICK CONCRETE FOUNDATION, SEE OTHER DETAILS FOR MORE INFO OPTIONAL CONTROL JOINT AT EACH END OF STEP 72" MAX SPAN EQ.EQ.24" MINDETAIL B 3" MIN TYPCONCRETE STRIP FOOTING 11B DETAIL A 36" MIN STEP 2 x STEP STEPNOTE: DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEP LOCATIONS SHOWN REAR FROST WALL LOOKOUT WALL FULL HEIGHT WALL GARAGE FROST WALL ELEVATION SHOWN FOR REPRESENTATION PURPOSES ONLY -MAY NOT APPLYELEVATION STEP SPACING REQUIREMENTS A TYP. COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 153 4.001 January 1, 2024 S3 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS STEP FOOTING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN. WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION OPTIONAL STEM WALL MINIMUM THICKNESS TO MATCH SILL PLATE SILL PLATE TO MATCH FRAME WALL ABOVE 16" MAX FOR 4" THICK STEM 24" MAX. FOR 6" THICK STEM SLAB-ON-GRADE BY OTHERS (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL 6" MIN. C.I.P. CONCRETE FOUNDATION WALL UNREINFORCED CONCRETE STRIP FOOTING SEE S7 #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) DOWELS ARE NOT REQUIRED IF BACKFILL IS PLACED EQUALLY ON BOTH SIDES IN LIFTS NOT TO EXCEED 24"-ALTERNATE EACH SIDE COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 154 4.001 January 1, 2024 S4 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS WALKOUT WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN.3'-0" MAX GRADE HEIGHTABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN. EMBED) CENTERED IN WALL @ 48" O.C. (SAND SOIL) OR 36" O.C. (SANDY-CLAY SOIL) OR 24" O.C. (CLAY SOIL) DOWELS MUST BE WET SET OR DRILLED AND EPOXY GROUTED 6" MIN. THICK C.I.P. CONCRETE FOUNDATION WALL SLOPE GRADE AWAY FROM FOUNDATION 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS (1) #4 x CONT HORIZONTAL BAR AT TOP OF WALL FRAMING & SILL PLATE BY OTHERS SLAB-ON-GRADE BY OTHERS UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (18" MIN WIDTH FOR CLAY BACKFILL OR 16" MIN WIDTH IF 2'-6" MAX UNBALANCED BACKFILL) COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 155 4.001 January 1, 2024 S5 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS LOOKOUT/KNEE WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6'-0" MAXWOOD FRAMING ABOVE BY OTHERS 12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED) @ 72" O.C. MAX. OR EQUIVALENT METAL STRAP ANCHORS SLOPE GRADE AWAY FROM FOUNDATION AT A GRADUAL 2% SLOPE PER GENERAL NOTE 6 SILL PLATE TO MATCH FRAME WALL ABOVE #4 x CONTINUOUS HORIZONTAL BARS @ 24" O.C. TYP. OPTIONAL 2" RIGID INSULATION ON INSIDE FACE AND UNDER SLAB-ON-GRADE FOR 24" MIN. UNREINFORCED CONCRETE STRIP FOOTING SEE S7 (DROP FOR FROST AS REQUIRED PER SITE DESIGN) #4x2'-0" DOWELS @ 48" O.C. MAX (5" MIN. EMBED) (1) #4 x CONTINUOUS HORIZONTAL BAR AT TOP OF WALL OPTIONAL SLAB LEDGE CONCRETE SLAB-ON-GRADE 8" MIN. C.I.P. CONCRETE FOUNDATION WALL #4 x 5'-0" HOOKS @ 24" O.C. EMBEDDED IN FOUNDATION WALL & CAST INTO SLAB (MAY REDUCE 2'-0" LEG LENGTH & DRILL IN & EPOXY 8" MIN. INTO FOUNDATION WALL) 3'-0"NO HOOKS @ 3'-0" OR LESSGRANULAR MATERIAL (SAND) DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0" #5 VERTICAL BARS @ 24" O.C. CENTERED IN WALL TO AID IN THE REDUCTION OF CRACKING AND BACKFILLING ISSUES PRIOR TO TOP OF WALL PINNING CONTRACTOR IS TO PROVIDE TEMPORARY TOP OF WALL BRACING UNTIL GARAGE SLAB-ON-GRADE IS IN PLACE (HOOKS INTO GARAGE SLAB PROVIDE REQUIRED TOP OF WALL LATERAL SUPPORT)2'-0" COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 156 4.001 January 1, 2024 S6 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS UNBALANCED FOUNDATION DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6" MIN. CLEAR HEIGHTBACKFILL HEIGHT112" CLEAR UNREINFORCED CONCRETE STRIP FOOTING PER CODE OR BY BUILDING DESIGNER, AS AN ALTERNATIVE GUIDE USE TABLE SHOWN BELOW 8" MIN. C.I.P. CONCRETE FOUNDATION WALL-SEE REBAR TABLE S8 FOR VERTICAL REBAR ANCHOR BOLTS SEE WALL ANCHOR INFO ON S11 FLOOR TO SILL CONNECTION SEE S10 WOOD FLOOR SYSTEM BY OTHERS SLOPE GRADE AWAY FROM FOUNDATION 2x6 MIN SILL PLATE CLEAR HEIGHT OF 8'-0" OR LESS (2)#4xCONT. HORIZONTAL BARS CLEAR HEIGHT OF 8'-0" OR MORE (3)#4xCONT. HORIZONTAL BARS CONCRETE SLAB-ON-GRADE PLACED TIGHT TO FOUNDATION WALL #4x2'-0" DOWELS @ 72" O.C. MAX (5" MIN. EMBED) GENERAL STRIP FOOTING SIZE GUIDE SOIL ONE-STORY STRUCTURE TWO-STORY STRUCTURE 2000 PSF 16" WIDE x 8" THICK 20" WIDE x 8" THICK 1500 PSF 20" WIDE x 8" THICK 26" WIDE x 8" THICK THIS TABLE IS A GENERAL FOOTING SIZE GUIDE FOR TRIBUTARY UNIFORM LOADING ONLY BASED ON MAXIMUM 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS AND IS TO BE VERIFIED BY HOME DESIGNER. FURTHER CONSIDERATION IS TO BE TAKEN BY HOME DESIGNER FOR VENEER WEIGHT, WALL THICKNESSES OVER 10", AND FLOOR AND ROOF DEAD LOADS OVER 15 PSF. CONCENTRATED LOADS FROM GIRDER TRUSSES, BEAMS, HEADERS, ETC. ARE TO BE ACCOUNTED FOR AND SIZED INDEPENDENTLY OF THIS GUIDE BY OTHERS. COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 157 4.001 January 1, 2024 S7 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS BASEMENT WALL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE S7)BACKFILL HEIGHT(SEE S7)7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10" 12"8"10" 12"8"10" 12"NONE NONE NONENONE NONENONE NONENONE NONENONENONENONENONENONENONENONENONE NONENONE NONENONENONENONENONENONENONENONENONENONENONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24" 24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)8'-0" OR LESS9'-0" MAX.10'-0" MAX. COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 158 4.001 January 1, 2024 S8 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS VERTICAL REINFORCING TABLE Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S7 WOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 16" HIGH MAX x 6" THICK MIN STEM6"MINWOOD FLOOR SYSTEM BY OTHERS FRAMING BY OTHERS 6" MIN THICK STEM #4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL FOUNDATION WALL SEE S7 VENEER OR SLAB-ON-GRADE BY OTHERS 12"VENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S4 OR S5 FRAMING BY OTHERS 16" HIGH MAX x 4" THICK MIN STEM THICKNESS TO MATCH SILL PLATE6"3'-0" MAXVENEER OR SLAB-ON-GRADE BY OTHERS FOUNDATION WALL SEE S6 SLAB-ON-GRADE FRAMING BY OTHERS 6" MIN THICK STEM DETAIL @ HIGH GRADE SIM @ NON-BEARING DETAIL @ LOOKOUT SIM @ FROST WALL DETAIL @ FROST WALLS w/ LOW GRADE DETAIL @ LOW GRADE SIM @ NON-BEARING 112" CLEAR MINMAX#4 DOWELS @ 36" O.C. EMBEDDED 24" INTO LOWER WALL (CENTER IN STEMWALL) SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION SLOPE GRADE AWAY FROM FOUNDATION NOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER. WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES. COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 159 4.001 January 1, 2024 S9 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS BRICK LEDGE DETAILS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICKx 2"Ø OR SQUARE WASHER SEE S11 FOR SPACING (7" EMBED MIN) -METAL STRAP ANCHORS TO BE INSTALLED AT MANUFACTURER EQUIVALENT SPACING FLOOR SYSTEM, TYPE, SIZE, AND SPACING TO BE DETERMINED BY OTHERS RIM BOARD OR BRACING MATERIAL BY OTHERS 2x6 SILL PLATE MINIMUM FLOOR TO SILL CONNECTION AT EACH MEMBER SEE TABLE BELOW WASHER TO BE COUNTERSUNK FLUSH w/ TOP OF SILL PLATE SEE FULL HEIGHT WALL SECTION ON S7 FOR FOUNDATION WALL REQUIREMENTS SLOPE GRADE AWAY FROM FOUNDATION MINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS**** BACKFILL TYPECLEAR HEIGHT (SEE S7) FLOOR MEMBER SPACING 16" 19.2" A (4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBER SAND (30 PSF/FT)SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 24" 16" 19.2" 24" 16" 19.2" 24" A A A A A A A B A A B B B B B C C C D D D D D D D C CONNECTION A (4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B (2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC AT EACH MEMBER CONNECTION C CONNECTION D (2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ** OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER * FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES, FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE. ** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH. *** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s. ****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE A STRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE. 2x8 SILL PLATE TO BE USED w/ MAXIMUM OF 112" OVERHANG (MAINTAIN 234" EDGE DISTANCE TO BOTH CONCRETE AND INSIDE OF SILL PLATE) - VERTICAL LOAD TRANSFER BY SUPPLIER 8'-0" OR LESS 9'-0" MAX. 10'-0" MAX. COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 1510 4.001 January 1, 2024 S10 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS FLOOR BEARING CONNECTIONS Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS* ALTERNATIVE TO CODE TABLE R404.1.(1) BACKFILL TYPE CLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 72" * 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWN SAND (30 PSF/FT)SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 72" 48" 60" 72" 48" 60" 72" 36" 48" 72" 36" 36" 72" 72"72" 48" 24" 24" ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS** ALTERNATIVE TO CODE TABLE R404.1.(1) BACKFILL TYPECLEAR HEIGHT (SEE S7) BACKFILL HEIGHT (SEE S7) 7'-6" 7'-0" 8'-6" 8'-0" 7'-0" OR LESS 9'-6" 9'-0" 8'-0" 7'-0" OR LESS 48" ** APPLIES TO 12"Ø EXPANSION BOLT w/ 6" EMBED, 12"Ø SELF-CUTTINGANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHOR SAND (30 PSF/FT) SANDY CLAY (45 PSF/FT) CLAY (60 PSF/FT) 6'-0" OR LESS 60" 72" 30" 36" 72" 18" 24" 42" 72" 72" 24" 18" 20" 24" 18" 24" 24" 30" 42" 16" 12" 14" 16" 12" 16" 36" 36" N/A N/A 8'-0" OR LESS 9'-0" MAX. 10'-0" MAX. 8'-0" OR LESS 9'-0" MAX. 10'-0" MAX. COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 1511 4.001 January 1, 2024 S11 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS ANCHOR SPACING TABLES Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR @ BLOCKING SEES102 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWN ORSHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE. COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 1512 4.001 January 1, 2024 S12 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS NON BEARING JOIST BLOCKING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE S102 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE S11 FOR SPACING OFBLOCKING SYSTEM SHOWN COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 1513 4.001 January 1, 2024 S13 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS NON-BEARING TRUSS BLOCKING DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 10'-0" MAX3'-0" MAX GRADE HEIGHTABOVE TOP OF SLAB1'-6" MIN3'-0" EACH WAY MIN 112" TYPSLOPE GRADE AWAY FROM FOUNDATION #4 HORIZONTAL BARS @ 12" O.C. CENTERED IN WALLS LAP AROUND CORNERS AND HOOK INTO FOUNDATION WALL @ EACH SIDE (REFER TO S7 FOR HORZ. BAR REQUIREMENTS w/ 8" C.I.P. WALLS) 6" MIN C.I.P. CONCRETE WALL #4 VERTICAL BARS @ EACH OUTSIDE CORNER OF WELL (1)#4 x2'-0" DOWEL @ EACH OUTSIDE CORNER OF WELL (5" MIN EMBED) 12" WIDE x 8" THICK MIN STRIP FOOTING (1) #4 HORIZONTAL BAR AT TOP OF WALL (2) #4 HORIZONTAL BARS TOP & BOTTOM OF LINTEL EXTEND 24" MIN PAST OPENING EACH END (WOOD OR STEEL OPTION BY OTHERS) WALL BEYOND PLACE (2) #4 VERTICAL BARS FULL HEIGHT AND ONE ANCHOR w/IN 12" OF OPENING EACH END 8" MIN C.I.P. CONCRETE WALL SLAB-ON-GRADE UNREINFORCED CONCRETE STRIP FOOTING SEE FULL HEIGHT WALL SECTION S7 LOOKOUT WALL SEE S5 GRANULAR MATERIAL (SAND) SLOPE WINDOW WELL LADDER/ ESCAPE MEANS BY OTHERS 5'-0" EACH WAY MAX FLOOR SYSTEM BY OTHERS (DO NOT PLACE GIRDERS OR BEAMS OVER CONCRETE LINTEL DESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL AT THE DISCRETION OF THE BUILDER FOR ADDITIONAL FROST PROTECTION AS REQUIRED PER SITE DESIGN 6" MIN. COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 1514 4.001 January 1, 2024 S14 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS WINDOW WELL DETAIL Project: Client: RevDateSITE ADDRESS: State:Zip:MN 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 6'-0" MAX. 8" MIN. GRAD E L I N E 9'-4" MAX.6'-0" MAX.4'-0" MAX.SEE BASEMENT WALL DETAILSEE LOOKOUT WALL DETAILSIM.CONSTRUCT SIM. LOOKOUT WALLw/ MIN. (2) #4 HORIZ. BARS3 MIN. 1 S7S5S5SLAB-ON-GRADE BEYOND CONCRETE STRIP FOOTING STEP DOWN AS REQ'D FOR FROST PROTECTION AT NON-BEARING WALLS, LOCATE BLOCKING DETAILS (S12 / S13) AT END OF FULL HEIGHT WALL PROVIDE (2) ADDITIONAL #4 BARS @ END OF FULL HEIGHT WALL SEGMENT LOCATED 2" FROM INSIDE WALL FACE FLOOR FRAMING ABOVE BY OTHERS INFILL WOOD FRAMING BY OTHERS COPYRIGHT HANSON GROUP LLC 2024© City: ofSheet: Drawing Date: Project Number: 1515 4.001 January 1, 2024 S15 Project: Client: RevDateSITE ADDRESS: State:Zip:MN 2024 C.I.P. CONCRETE FOUNDATION GUIDELINE DRAWINGS STEPPING DOWN WALL WITH GRADE 5851 Cedar Lake Road Suite 202St. Louis Park, MN 55416 Tel 612-708-3572www.hansongroupmn.com &TGYU%QPETGVG+PE 21$QZ 5JCMQRGG/0 Passive (No Fan) Active (With fan and monitoring device ) Location (or future location) of Fan: Other Please Describe Here Not applicable, all ducts located in conditioned space Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS: Capacity in Gallons: Other, describe: AFUE or HSPF% Cfm's " round duct OR " metal duct Not required per mech. code Passive Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor MN License Number City Mailing Address of the Dwelling or Dwelling Unit Rigid, Extruded PolystyreneHeat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: Combustion Air Select a Type Location of duct or system: Rim Joist (2nd Floor+) Building envelope air tightness: Below Entire Slab Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area THERMAL ENVELOPE Foam Open Cell Wall Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM Total R-Value of all Types of InsulationType: Check All That Apply Mineral FiberboardInsulation Location Foam, Closed Cell Describe other insulated areas Ceiling, flat Non or Not ApplicableFiberglass, BlownFiberglass, Batts Foundation Wall Output in Tons: Appliances Cooling System Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Make-up Air Select a Type Domestic Water Heater Model Heating System Rim Joist (1st Floor) Average U-Factor (excludes skylights and one door ) U: Duct system air tightness: Rating or Size Efficiency Heating Gain Cooling Load Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation SEER /EER Capacity continuous ventilation rate in cfms: Heating Loss Manufacturer Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM Date Cert. Posted R-value MECHANICAL SYSTEMS Builders Associaton of Minnesota version 101014 Site address Date 6/17/2024 Contractor Silver Tree Plumbing & Heating, LLC By Jake Ryan Section A Square feet (Conditioned area inc. 5114 TOTAL VENTILATION 192 basement – finished or unfinished)CONTINUOUS VENTILATION 96 Number of bedrooms 5 # of BEDROOMS 1 2 3 4 5 6 Total/ Total/ Total/ Total/ Total/ Total/ continuous continuous continuous continuous continuous continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 4501-5000 130/65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 150/75 165/;83 180/90 195/98 210/105 225/113 Equation R403.5.2 2015 Mn Energy Code (0.02 x conditioned space) + (15 X (# of bedrooms + 1))= TOTAL VENTILATION RATE Sq Ft 5114 0.02 102.28 Bedrooms 5 15 75 Plus 1 bedroom 15 TOTAL VENT 192.28 CFM Section B Low cfm: High cfm: 96 192 Section D Control Set at 40%96 CFM HIGH set at 80%216 CFM (BALANCED) Table R403.5.2 2015 Minnesota Energy Code Total and Continuous Ventilation Rates (in cfm) Conditioned space (in sq. ft.) 2015 Mechanical & Energy Code – Ventilation, Makeup, and Combustion Air Calculations Ventilation Method 18885 Javelin Way, Lakeville Ventilation Quantity (Determine quantity by using Table R403.5.2 or Equation R403.5..2, 2015 Minnesota Energy Code) ☒Balanced, HRV (Heat Recovery Ventilator) or ERV (Energy Recovery Ventilator) – cfm of unit in low must not exceed continuous ventilation rating by more than 100%. Ventilation Controls (Describe operation and control of the continuous ventilation) Page 1 of 6 Page 2 of 6 One or multiple power vent or direct vent appliances or no combustion appliances One or multiple fan- assisted appliances and power vent or direct vent appliances One atmospherically vented gas or oil appliance or one solid fuel appliance Multiple atmospherically vented gas or oil appliances or solid fuel appliances Column A Column B Column C Column D 1.Enter the Appropriate Column to Estimate House Infiltration a) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03 b) conditioned floor area (sf) (including unfinished basements) 5114 Estimated House Infiltration (cfm): [1a x 1b]767.1 2. Exhaust Capacity ERV/HRV=0 a) clothes dryer (cfm)135 135 135 135 b) 80% of largest exhaust rating (cfm); (not applicable if recirculating system or if powered makeup air is electrically interlocked and match to exhaust) 240 c) 80% of next largest exhaust rating (cfm); NA (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) Total Exhaust Capacity (cfm);375 [2a + 2b +2c] 3. Makeup Air Quantity (cfm) a) total exhaust capacity (from above)375 b) estimated house infiltration (from above)767.1 Makeup Air Quantity (cfm); [3a – 3b]-392.1 (if value is negative, no makeup air is needed) 4. For makeup Air Opening Sizing, refer to Table 501.4.2 Not required, negative number A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances. (Power vent and direct vent appliances may be used.) B. Use this column if there is one fan-assisted appliance per venting system. (Appliances other than atmospherically vented appliances may also be included.) C. Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. Directions - In order to determine the makeup air for ventilation, Table 501.4.1 must be filled out (see below). For most new installations, column A will be appropriate, however, if kitchen hoods exceed 300 cfm, atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column. Please note, if the makeup air quantity is negative, no additional makeup air will be required for ventilation, if the value is positive refer to Table 501.4.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to the last line of section D. The ventilation make-up air supply must communicate with the exhaust appliances. Table 501.4.1, 2015 Minnesota Mechanical Code PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST APPLIANCES IN DWELLING UNITS (Additional makeup air will be required for combustion appliances, see KAIR method for calculations) Be advised: 2015 Minnesota Mechanical Code, Section 505.2, Installation of exhaust hood systems capable of exhausting in excess of 400 cfm shall be provide with makeup air at a rate approximately equal to the exhaust air rate. Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system. Page 3 of 6 Section E Passive (determined from calculations from 2015 Minnesota Mechanical Code, Table 501.4.1) Powered (determined from calculations from 2015 Minnesota Mechanical Code, Table 501.4.1) Interlocked with exhaust device (determined from calculations from 2015 Minnesota Mechanical Code, Table 501.4.1) Other, describe: Location of duct or system ventilation make-up air: (Determined from make-up air opening table, Table 501.4.2.) Not Required -392.1 Makeup Air Opening Table for New and Existing Dwelling Table 501.4.2, 2015 Minnesota Mechanical Code One or multiple power vent, direct vent appliances, or no combustion appliances One or multiple fan- assisted appliances and power vent or direct vent appliances One atmospherically vented gas or oil appliance or one solid fuel appliance Multiple atmospherically vented gas or oil appliances or solid fuel appliances Column A Column B Column C Column D Duct diameter Passive opening 1 – 36 1 – 22 1 – 15 1 – 9 3 Passive opening 37 – 66 23 – 41 16 – 28 10 – 17 4 Passive opening 67 – 109 42 – 66 29 – 46 18 – 28 5 Passive opening 110 - 163 67 – 100 47 – 69 29 – 42 6 Passive opening 164 – 232 101 – 143 70 – 99 43 – 61 7 Passive opening 233 – 317 144 – 195 100 – 135 62 – 83 8 Passive opening w/motorized damper 318 – 419 196 – 258 136 – 179 84 – 110 9 Passive opening w/motorized damper 420 – 539 259 – 332 180 – 230 111 – 142 10 Passive opening w/motorized damper 540 – 679 333 – 419 231 – 290 143 – 179 11 Powered makeup air >679 >419 >290 >179 NA Notes: A. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90- degree elbow to determine the remaining length of straight duct allowable. B. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. Compressed duct shall not be accepted. C. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. D. Powered makeup air shall be electrically interlocked with the largest exhaust system. Sections F X Size and type FLEX= RIGID= Other, describe: Not required per mechanical code (No atmospheric or power vented appliances) Make-up air for COMBUSTION Passive (see IFGC Appendix E, Worksheet E-1) Explanation - If no atmospheric or power vented appliances are installed, check the appropriate box, not required. If a power vented or atmospherically vented appliance installed, use IFGC Appendix E, Worksheet E-1 (see below). Please enter size and type. Combustion air vent supplies must communicate with the appliance or appliances that require the combustion air. Directions - The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening, is called the Known Air Infiltration Rate Method (KAIR). For new construction, 4b of step 4 is required to be filled out. The example assumes a typical 3,000 square foot home with a finished basement that has a mechanical room that is 10 feet wide by 12 feet long with an 8 foot ceiling. It also assumes installation of a 70,000 btu, 2 pipe condensing furnace; and a 40,000 Btu, power vented water heater. Make-up air for VENTILATION Size and type (round, rectangular, flex or rigid) Page 4 of 6 Furnace/Boiler: Water Heater: INPUT in BTUHS:0 CAS VOLUME:1872 Mech Room Length:18 Mech Room Width:13 Mech Room Height:8 Cubic feet INPUT (BTUH/HOUR)= TRV (ft3)= INPUT (BTUH/HOUR)=0 RVFA (Ft3)=3000 INPUT (BTUH/HOUR)=0 RVNFA (Ft3)=NONE RVFA:3000 RVNFA (Ft3)=0 3000 Ft3 RATIO=1872 DIVIDED BY 3000 EQUALS:0.62 RF = 1 minus Ratio Ratio RF=1 MINUS 0.62 EQUALS:0.38 INPUT (BTUH/HOUR)=0 CAOA=0 divided by 3000 EQUALS:0.00 BTUH/HR per in2 MIN CAOA=0.00 X 0.38 0.00 Square Inches CAOD= 1.13 X Square root Minimum CAOA=0.00 inches Step 1: Complete vented combustion appliance information. __ Draft Hood __ Fan Assisted __-Direct Vent XX FURNACE IS SEALED COMBUSTION (for Furnace, Boiler, and/or Water Heater in the Same Space) IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method Total Btu/hr input of all fan-assisted and power vent appliances Step 4: Determine Required Volume for Combustion Air. 4a. Standard Method Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. Step 3: Determine Air Changes per Hour (ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method). If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. 4b. Known Air Infiltration Rate (KAIR) Method __ Draft Hood (Non- fan assist) __ Fan Assisted & Power Vent __ Direct Vent _X_Electric Total Btu/hr input of all combustion appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Use Standard Method column in Table E-1 to find Total Required Volume (TRV) Step 6: Calculate Reduction Factor (RF). (DO NOT COUNT DIRECT VENT APPLIANCES) Use Fan-Assisted Appliances column in Table E-1 to find Required Volume Fan Assisted (RVFA) Total Btu/hr input of all non-fan-assisted appliances Use Non-Fan-Assisted Appliances column in Table E-1 to find Required Volume Non-Fan-Assisted (RVNFA) Total Required Volume (TRV) = RVFA + RVNFA 1 If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section G304 Minimum CAOA = CAOA multiplied by RF Step 9: Calculate Combustion Air Opening Diameter (CAOD) CAOD = 1.13 multiplied by the square root of Minimum CAOA Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per in2 Step 8: Calculate Minimum CAOA. If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Page 5 of 6 Input Rating (Btu/hr) 1994 to present Pre-1994 1994 to present Pre-1994 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,675 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8.625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 IFGC Appendix E, Table E-1 Residential Combustion air (Required Interior Volume Based on Input Rating of Appliance) Standard Method Known Air Infiltration Rate (KAIR) Method (cu ft) Fan Assisted Non-Fan Assisted 1.     The 1994 date refers to dwelling constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is .20 air changes per hour (ACH). 2.     This section of the table is to be used for dwelling constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH. Although this worksheet, IFGC Appendix E, Worksheet E-1 and the following worksheet, IFGC Appendix E, Table E-1, is referenced in the 2015 Minnesota Fuel Gas Code, these worksheets were not included in the published copy. Page 6 of 6 TOTAL INPUT OF APPLIANCES1, THOUSANDS OF Btu/hr (kW) REQUIRED FREE AREA OF AIR-SUPPLY OPENING OR DUCT, SQUARE INCHES (sq mm) ACCEPTABLE APPROXIMATE ROUND DUCT EQUIVALENT DIAMETER2, INCH (mm) 25 (8)7 (4,500)3 (75) 50 (15)7 (4,500)3 (75) 75(23)11 (7,000)4 (100) 100 (30)14 (9,000)4 (100) 125 (37)18 (12,000)5 (125) 150 (45)22 (14,000)5 (125) 175 (53)25 (16,000)6 (150) 200 (60)29 (19,000)6 (150) 225 (68)32 (21,000)6 (150) 250 (75)36 (23,000)7 (175) 275 (83)40 (26,000)7 (175) 300 (90)43 (28,000)7 (175) 325 (98)47 (30,000)8 (200) 350 (105)50 (32,000)8 (200) 375 (113)54 (35,000)8 (200) 400 (120)58 (37,000)9 (225) 1. For total inputs falling between listed capacities, use next largest listed input. 2. If flexible duct is used, increase the duct diameter by one inch. * *Flexible duct shall be stretched with minimal sags. TABLE 304.1 COMBUSTION AIR REQUIREMENTS FOR GAS-FIRED APPLIANCES WHEN THE COMBINED INPUT IS UP TO AND INCLUDING 400,000 Btu/hr BTU Amount for Non-direct vent appliances_____________________ 1 2 3 4 5 6 2 Conditioned space1 (in sq. ft.) Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous Total/ Continuous 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 4501-5000 130-65 145/73 160/80 175/88 190/95 205/103 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 5501-6000 2 150/75 165/83 180/90 195/98 210/105 225/113 1. Conditioned space includes the basement and conditioned crawl spaces. 2. If conditioned space exceeds 6000 sq. ft. or there are more than 6 bedrooms, use Equation R403.5.2 R403.5.2 Total Ventilation rate. The mechanical ventilation system shall rovide sufficient outdoor air to equal the total ventilation rate average for each 1- hour period in accordance with Table R403.5.2, or Equation 403.5.2, based on the number of bedrooms and square footage of conditioned space, including the basement and conditioned crawl spaces. For the purposes of Table R403.5.2 and Section R403.5.3, the following applies: a. Equation R403.5.2 Total ventilation rate: Total ventilation rate (cfm) = (0.02 x square feet of conditioned space) + (15 x (number of bedrooms +1)) b. Equation R403.5.2.1 Continuous ventilation rate: Continuous ventilation rate (cfm) = Total ventiation rate/2 Amount Total _________________________ Amount Continuous____________________ TABLE R403.5.2 NUMBER OF BEDROOMS VENTILATION REQUIREMENTS ONE OR MULTIPLE POWER VENT OR DIRECT VENT APPLIANCES OR NO COMBUSTION APPLIANCESA ONE OR MULTIPLE FAN- ASSISTED APPLIANCES AND POWER VENT OR DIRECT VENT APPLIANCESB ONE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANE OR ONE SOLID FUEL APPLIANCEC MULTIPLE APPLIANCES THAT ARE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCES OR SOLID FUEL APPLIANCESD 1. Use the Appropriate Column to Estimate House Infiltration a) pressure factor (cfm/sf) b) conditioned floor area (sf) (including unfinished basements) Estimated House Infiltration (cfm): [1a x 1b] 2. Exhaust Capacity a) clothes dryer b) 80% of largest exhaust rating (cfm): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) c) 80% of next largest exhaust rating (cfm):not applicable (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) Total Exhaust Capacity (cfm): [2a+2b+2c] 3. Makeup Air Requirement a) Total Exhaust Capacity (from above) b) Estimated House Infiltration (from above) Makeup Air Quality (cfm): [3a - 3b] (if value is negative, no makeup air is needed 4. For Makeup Air Opening Sizing, refer to Table 501.4.2. A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances. B. Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. C. Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. Table 501.4.1 Procedure to Determine Makeup Air Quantity for Exhaust Appliances in Dwelling Units Choose Which Applies TYPE OF OPENING ONE OR MULTIPLE POWER VENT OR DIRECT VENT APPLIANCES OR NO COMBUSTION APPLIANCESA ONE OR MULTIPLE FAN- ASSISTED APPLIANCES AND POWER VENT OR DIRECT VENT APPLIANCESB ONE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCE OR ONE SOLID FUEL APPLIANCEC MULTIPLE APPLIANCES THAT ARE ATMOSPHERICALLY VENTED GAS OR OIL APPLIANCES OR SOLID FUEL APPLIANCESD PASSIVE MAKEUP AIR OPENING DUCT DIAMETERE,F,G OR SYSTEM (cfm)(cfm)(cfm)(cfm)(inches) Passive opening 1-36 1-22 1-15 1-9 3 Passive opening 37-66 23-41 16-28 10-17 4 Passive opening 67-109 42-66 29-46 18-28 5 Passive opening 110-163 67-100 47-69 29-42 6 Passive opening 164-232 101-143 70-99 43-61 7 Passive opening 233-317 144-195 100-135 62-83 8 Passive opening with motorized damper 318-419 196-258 136-179 84-110 9 Passive opening with motorized damper 420-539 259-332 180-230 111-142 10 Passive opening with motorized damper 540-679 333-419 231-290 143-179 11 Powered makeup airH >679 >419 >290 >179 Not applicable A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances. B. Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. C. Use this column if there is one atmospherically vented (ther than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. E. An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90-degree elbow to determine the remaining length of straight duct allowable. F. If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. G. Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed. H. Powered makeup air shall be electrically interlocked with the largest exhaust system. Table 501.4.2 Makeup Air Opening Sizing Table for New and Existing Dwelling Units IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) Step 1: Complete vented combution appliace information: Furnace/Boiler: Draft Hood Fan Assisted Direct Vent Input: Btu/hr (Not fan Assisted) & Power Vent Water Heater: Draft Hood Fan Assisted Direct Vent Input: Btu/hr ( Not fan Assisted) & Power Vent Step 2: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. The CAS includes all spaces connected to one another by code compliant openings. CAS volume: ft3 Step 3: Determine air Changes per Hour (ACH)1 Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method). Step 4: Determine Required Volume for Combustion Air. 4a. Standard Method Total Btu/hr input of all combustion appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Input: Btu/hr Use Standard Method column in Table E-1 to find Total Required Volume (TRV) TRV: ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. 4b. Known Air Infiltration Rate (KAIR) Method Total Btu/hr input of all fan-assisted and power vent appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Input: Btu/hr Use Fan-Assisted Appliances column in Table E-1 to find Required Volume Fan Assisted (RVFA) RVFA: ft3 Total Btu/hr input of all non-fan-assisted appliances Input: Btu/hr Use Non-Fan-Assisted Appliances column in Table E-1 to find Required Volume Non-Fan-Assisted (RVNFA) RVNFA: ft3 Total Required Volume (TRV) = RVFA + RVNFA TRV = + = ft3 If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Step 5: Calculate the ratio of available interior volume to the total required volume. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Ratio = Step 6: Calculate Reduction Factor (RF). RF = 1 minus Ratio RF = - = Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Input: Btu/hr Combustion Air Opening Area (CAOA): Total Btu/hr divided by 3000 Btu/hr per in2 / Btu/hr per in 2 = in2 Step 8: Calculate Minimum CAOA. Minimum CAOA = CAOA multiplied by RF Minimum CAOA = x = in2 Step 9: Calculate Combustion Air Opening Diameter (CAOD) CAOD = 1.13 multiplied by the square root of Minimum CAOA CAOD = 1.13 x Minimum CAOA = in 1If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section 304. CAOA = Electric IFGC Appendix E, Table E-1 Residential Combustion Air Required Volume (Required Interior Volume Based on Input Rating of Appliances) Known Air Infiltration Rate (KAIR) Method (ft3) Input Rating Standard Method Fan Assisted Non-Fan-Assisted (Btu/hr) (ft3) 19941 to Present Pre 19942 19941 to Present Pre 19942 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,050 25,000 1,250 1,875 938 2,625 1,313 30,000 1,500 2,250 1,125 3,150 1,575 35,000 1,750 2,625 1,313 3,675 1,838 40,000 2,000 3,000 1,500 4,200 2,100 45,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,875 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,150 65,000 3,250 4,875 2,438 6,825 3,413 70,000 3,500 5,250 2,625 7,350 3,675 75,000 3,750 5,625 2,813 7,875 3,938 80,000 4,000 6,000 3,000 8,400 4,200 85,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250 105,000 5,250 7,875 3,938 11,025 5,513 110,000 5,500 8,250 4,125 11,550 5,775 115,000 5,750 8,625 4,313 12,075 6,038 120,000 6,000 9,000 4,500 12,600 6,300 125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613 150,000 7,500 11,250 5,625 15,750 7,875 155,000 7,750 11,625 5,813 16,275 8,138 160,000 8,000 12,000 6,000 16,800 8,400 165,000 8,250 12,375 6,188 17,325 8,663 170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713 190,000 9,500 14,250 7,125 19,950 9,975 195,000 9,750 14,625 7,313 20,475 10,238 200,000 10,000 15,000 7,500 21,000 10,500 205,000 10,250 15,375 7,688 21,525 10,763 210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,857 8,438 23,625 11,813 230,000 11,500 17,250 8,625 24,150 12,075 1The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is 0.20 ACH. 2This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-Jun-13 14:14:05Right-Suite® Universal 2024 24.0.01 RSU60948 Page 1 ...JH - 18885 Javelin Way, Lakeville (Watkins).rup Calc = MJ8 Front Door faces: N Job:Load Short Form 6/12/2024Date:Entire House Jake RyanBy: WatkinsPlan:Silver Tree Plumbing and Heating LLC 1335 Mendota Heights Rd, Mendota Heights, MN 55120 Phone: 651-319-4200 Email: jaker@silvertreepandh.com Web: www.silvertreeph.com Project Information Watkins, Country Joe HomesFor: 18885 Javelin Way, Lakeville, MN 55044 Design Information InfiltrationClgHtg Blower doorMethod87-9Outside db (°F) 3 (partial) / 2Shielding / stories7570Inside db (°F) 50 Pa / 1.5 / 966 cfmPressure /ACH /AVF1279Design TD (°F) M-Daily range 5030Inside humidity (%) 3631Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Bryant Make Bryant Trade Bryant Legacy 92 Single Stage ...Trade 14 SEER2 AC Model 912SE48080M17 Cond GA4SAN43600NA0 AHRI ref 211778833 Coil CVPVA3617XMC+912SD48080E17 AHRI ref 209018269Efficiency92.1 AFUE Efficiency 12.0 EER2,14.5 SEER2 Heating input Btuh80000 Sensible cooling Btuh26880 Heating output Btuh75000 Latent cooling Btuh6720Temperature rise °F63 Total cooling Btuh33600 Actual air flow cfm1120 Actual air flow cfm1120 Air flow factor cfm/Btuh0.018 Air flow factor cfm/Btuh0.041 Static pressure in H2O0.80 Static pressure in H2O0.80 Space thermostat Load sensible heat ratio 0.88 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Bedroom #5 360 3217 709 57 29 LL Main Bath 58 91 0 2 0 Family Room 1002 12072 4260 215 177 LL Stairs 81 0 0 0 0Dining Room 140 4181 2159 74 90 Great Room 315 10048 6397 179 265 Kitchen 311 702 997 12 41Powder Bath 27 0 0 0 0 WIC Laundry 79 0 479 0 20 WIC 41 242 14 4 1 JR. Suite Bath 91 1405 773 25 32 Pantry 38 0 0 0 0 Study 163 2728 842 49 35 Foyer 187 2174 416 39 17 18885 Javelin Way Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2024-Jun-13 14:14:05Right-Suite® Universal 2024 24.0.01 RSU60948 Page 2 ...JH - 18885 Javelin Way, Lakeville (Watkins).rup Calc = MJ8 Front Door faces: N Main Floor Stairs 81 0 0 0 0 Hall 55 1794 1140 32 47 Bedroom #4 220 3631 1685 65 70 Mudroom 59 1253 294 22 12 Loft 69 367 116 7 5 Bedroom #2 207 3658 1023 65 42Bedroom #3 247 5094 1248 91 52 2nd Floor Hallway 83 514 120 9 5 Master Bath 189 2210 714 39 30 Master Bedroom 385 6569 2804 117 116 Main Bath 58 91 52 2 2 BR #3 WIC 39 727 153 13 6 Master BR WIC 60 94 54 2 2 2nd Floor Stairs 81 0 0 0 02nd Floor Laundry 80 125 550 2 23 Mechanical Room 306 0 0 0 0 Entire House 5110 62988 26996 1120 1120 Other equip loads 7155 446 Equip. @ 0.92 RSM 25110 Latent cooling 3718 TOTALS 5110 70143 28828 1120 1120 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. A National Pollutant Discharge Elimination System (NPDES) Construction Stormwater Permit is required for “Construction activity that results in land disturbance of equal to or greater than one (1) acre or if a project is part of a common plan of development that will ultimately disturb greater than one (1) acre,” (NPDES Permit, Section 1.2). Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ *Primary Company Contact: _________________________________________________________________ *Should a site be deemed noncompliant, this individual will be notified Phone #: ____________________________ Email: ______________________________________________ If you are not covered under a NPDES Construction Stormwater Permit administered by the Minnesota Pollution Control Agency (MPCA), an erosion and sediment control plan MUST be approved as part of the residential building permit application. “Permittees must ensure a trained person will inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than ½ inch in 24 hours,” (NPDES Permit, Section 11.2). The City of Lakeville reserves the right to request weekly inspection logs. The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name: ____________________________________ Company: ___________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: __________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed I understand the above information to be accurate and I have read, understood, and accepted all terms and conditions of the NPDES Permit (MN R 100001). Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 952-215-6391 rjarvi@countryjoehomes.com Rob Jarvi Youngfield Homes Rob Jarvi Youngfield Homes 952-215-6391 rjarvi@countryjoehomes.com University of Minnesota Steve Sauber 18885 Javelin Way 07/26/24 05/31/27 8/9/24 X PM