Loading...
HomeMy WebLinkAboutLA25722 - 20079 Gambit Pass-Permit PackRESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND EV4F SALEM -3 CAR 20079 Gambit Pass Cedar Hills-3rd Addition SCALE:A1.11FRONT ELEVATION1/4" = 1'- 0"SCALE:A1.12ROOF PLAN1/8" = 1'- 0"SCALE:A1.13SIDE ELEVATION1/8" = 1'- 0"SCALE:A1.14SIDE ELEVATION1/8" = 1'- 0"SCALE:A1.15REAR ELEVATION-LOOKOUT 1/8" = 1'- 0"SCALE:A1.15AREAR ELEVATION-WALKOUT1/8" = 1'- 0"SCALE:A1.11ACOLUMN DETAIL1/2" = 1'- 0"GARAGE HARDWARE PERCOMMUNITY SPECSEXTERIOR MATERIALS % LAP SIDING = 21% STONE = 44% SHAKE = 24% TRIM = 11%LP HORIZONTAL LAP SIDINGFACE APPLIED STONE VENEERHardboard Siding on Front Elevation.FACE APPLIED STONE VENEERHardboard Siding on Side and Rear Elevation.LP HORIZONTAL LAP SIDINGLP SHAKE SIDINGLP HORIZONTAL LAP SIDINGSecure door closed until deck isconstructed with a separate permit. 1/2" ROCK, 8" DEEP20" x 8" CONC. FTG.W/ SILL SEALER(TR) 2x6 SILL PLATEGRADER-20 BATT INSUL.BOLT AT 72" O.C.1/2" DIA. x 10" ANCHOR8" W. POURED CONC.FOUNDATION WALL CONC. SLABPER PLANEXT. FIN. PER PLANDOUBLE TOP PLATEHEADER AT WIN.4 MIL POLY8"2"WRB PER PLAN FLR. SYSTEMVAPOR BARRIERR-10 RIGID INSUL.OR APPROV. STRAP42" MIN.WATERPROOFINGREQ'D. @ TOP OFFDN. WALLR-20 INSUL. @ RIMRIM BOARD6" MIN.1/2" EXT. SHEATHINGCONC. SLAB20" x 8" CONC. FOOTINGFOUNDATION WALLDOUBLE TOP PLATEPER PLANFLR. SYSTEM8" W. POURED CONC.1/2" DIA. x 10" ANCHORBOLT AT 72" O.C.R-20 BATT INSUL.2x8 (TR.) SILL PLATEW/ SILL SEALERGRADEOR APPROV. STRAP3'-6"R-20 SPRAY FOAM INSUL.RIM BOARDR-10 EXT. FDN. INSUL.R-5 RIGIDINSULATIONWATERPROOFINGTOP OF FDN. WALLCANT PLATE 1 1/2"SQUASH BLOCKS@ ALL POINT LOADS2x8 STUDS @ 16" O.C.SIDE WALLWALKOUTFDN. ONLY4" WEEPS EVERY 6'WATERPROOFING6" MIN.1/2" ROCK, 8" DEEPEXT. FIN. PER PLANWRB 1/2" EXT. SHEATHINGAT FOUNDATION4" D. x 8" H. LEDGEPER PLANSUBFLOORFLOOR SYSTEMRIM BOARDCONC. STOOP7 3/4" ENTRY DR. MAX. TO10"30 MIL PVC MEMBRANESEAL ALL SEAMS,CORNERS & EDGES W/35 MIL POLYETHYLENEBACKED SYNTHETICBUTYL RUBBERADHESIVE MEMBRANE1/2" SHEATHING(2") R-10 EXTERIORR-20 SPRAY FOAM INSUL.WATERPROOFINGREQ'D.@ TOP FDN.FOUNDATION INSULATION2x8 SILL PLATEW/ ANCHOR BOLTS1 1/2" CANT'D. ALIGN W/ FDN. WALLTHRESHOLD SUBFLOORFLOOR JSTS/TRUSSES20"x8" CONC. 2x6 TOP PLATECONC. SLABPER PLANPER PLAN16" O.C. (TYP)2x6 STUDS @2x6 TREATEDPLATESECURED W/POWDEREDACTUATEDFASTENERS@ 24" O.C.1"4"x1/2" TRT'D.PLYWOOD,HOLD UP 1"FROM FTG.EACH SIDEBY ENGINEERFTG. U.N.O.4" CONC. SLABFLOOR SYSTEMGARAGE SLAB SLOPE: 4"20" x 8" CONC. FOOTINGPER PLAN20" x 8" CONC. FOOTING8"PER PLANWATERPROOFINGB.O. FTG.GRADE3'-6" MIN.VAPOR BARRIER8" GRANULAR FILL4" CONC. SLABTOP OF CURBTOP OF FDN.TREATED 2x SILLPLATE W/ SILL SEALERSHEATHINGEXT. MTR'L. PER PLANRIM BOARD (BY MFG.)5/8" GYP. SHEATHINGR-10 EXTERIOR FDN.INSULATION10"6"4"2" CERTI-STUD ATFOUNDATION LEDGER-20 SPRAY FOAMINSULATIONWATERPROOFINGREQ'D. AT TOP OFFOUNDATION WALL2x6 SILL PLATEW/ ANCHOR BOLT / STRAPNO CANT. AT GARAGESTD. RIM DETAILHOUSE BASELINE DIM.GAR. OUT TO OUT DIM.NOTE: NO R-5 INSUL.REQ'D. AT GAR./HOUSEINT. COMMON WALLS4" WEEPS EVERY 6'4"(PLATE SIZE PER PLAN)6"MIN.NOTE:FOUNDATION SHALL EXTENDABOVE THE FINISHED GRADEADJACENT TO THE FOUNDATIONAT ALL POINTS AT LEAST 6"FOUNDATION NOTES:·MAXIMUM WALL LENGTH WITHOUT A CONTROL JOINT TO BE 50'-0·PRIOR TO BACKFILLING, FOUNDATION WALLS MUST BE LATERALLY SUPPORTED BY FLOOR CONSTRUCTION ATBOTH TOP & BOTTOM OR BY ADEQUATE TEMPORARY BRACING·WALLS WITH EQUAL BACKFILL ON BOTH SIDES REQUIRE NO REINFORCING FOR WALL LENGTHS LESS THAN25'-0" LONG AND HORIZONTAL REINFORCING ONLY FOR WALLS LONGER THAN 25'-0"·EXTERIOR WATERPROOFING SHALL COMPLY W/ R406.2 PER 2020 MN RESIDENTIAL CODE, WATERPROOFINGSHALL EXTEND FROM TOP OF INSIDE EDGE, ACROSS TOP AND DOWN EXTERIOR FACE OF FOUNDATION WALLTO FOOTING·EXTERIOR FIBERBOARD INSULATION TO BE APPLIED OVER WATERPROOFING. ABOVE GRADE TO BE 2" THICKR-10 CERTISTUD OR EQUAL TO ALLOW FOR SIDING APPLICATION. BELOW GRADE TO BE R-10, 2 3/8" THICKFIBERBOARD (WATCHDOG OR EQUAL). SILL PLATE TO OVERHANG FOUNDATION BY 1 1/2" TO ALIGNFOUNDATION INSULATION WITH 1/2" SHEATHING ABOVE. A GROUND BREAKER PRODUCT WILL BE USED TOTRANSITION FINAL GRADE TO SIDING MATERIAL·2x8 STUD FRAMED WALLS AT LOOKOUT REAR/SIDE RETURNS AND WALKOUT SIDE RETURNS·ALL INTERIOR WALLS ARE 3 1/2", UNLESS NOTED OTHERWISE·ALL POINT LOAD SUPPORTS (JACK STUDS) TO BE CARRIED THRU EACH FLOOR LEVEL TO BEAR ONFOUNDATION, INSTALL BLOCKING IN FLOOR SYSTEM BELOW ALL POINT LOAD SUPPORTS·ALL WOOD IN CONTACT W/ CONCRETE TO BE PRESSURE TREATED WOOD·DISTANCE FROM T.O. FOOTING TO T.O. FOUNDATION WALL TO BE 8'-4" FOR 8' BASEMENT·EXPOSED FLOOR SYSTEM ABOVE UNFINISHED AREAS TO MEET R501.3 FIRE PROTECTION REQUIREMENTS·FLOOR TRUSS FLOOR SYSTEM, SEE TRUSS LAYOUTS FOR SIZE & SPACING REQUIREMENTSTREATED 2x10BACK TO ALLOW HOLD FNDTN. WALLFOR 2x BLOCKING8"8"SCALE:A2.11FOUNDATION PLAN1/4" = 1'- 0"SCALE:A2.11AFOUNDATION PLAN - WALKOUT1/4" = 1'- 0"SCALE:A2.13WALKOUT DETAIL3/4" = 1'- 0"SCALE:A2.16STOOP DETAIL3/4" = 1'- 0"SCALE:A2.12LOOKOUT DETAIL3/4" = 1'- 0"SCALE:A2.15BEARING WALL3/4" = 1'- 0"SCALE:A2.14NON-DROP'D GARAGE/COMMON WALL3/4" = 1'- 0"SCALE:A2.17FND. REAR WALL CORNER DTL.3/4" = 1'- 0"UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. NOTE:WINDOW FALL PROTECTION TO BE PROVIDEDIN ACCORDANCE WITH R312.2.1GENERAL NOTES:·FIRST FLOOR CEILINGS TO BE 9'-1 1/8" ROUGH CEILING HEIGHT (U.N.O.)·T.O. FIRST FLOOR WINDOWS TO BE FRAMED AT 7'-11" (U.N.O.)·SECOND FLOOR CEILINGS TO BE 8'-1 1/8" ROUGH CEILING HEIGHT (U.N.O.)·T.O. SECOND FLOOR WINDOWS TO BE FRAMED AT 6'-11" (U.N.O.)·ALL EXTERIOR HOUSE WALLS TO BE 2x6 @ 16" O.C. (U.N.O.)·GARAGE/HOUSE COMMON WALLS TO BE 2x6 @ 16" O.C. (U.N.0.)·GARAGE WALLS TO BE 2x4 @ 16" O.C. (U.N.O.)·INSTALL 5/8" FIRECODE GYPSUM BOARD ON ALL GARAGE CEILINGS AND ADJOININGHOUSE WALLS·ALL INTERIOR HOUSE WALLS TO HAVE 1/2" GYPSUM BOARD, ALL HOUSE CEILINGS TOHAVE 5/8" FIRECODE GYPSUM BOARD·INTERIOR WALLS TO BE 2x4, WITH EXCEPTION TO THE 2x6 PLUMBING & BEARING WALLSPER PLAN (U.N.O.) ALL INTERIOR WALLS FRAMED @ 16" O.C.·ALL ANGLED WALLS ARE 45 DEGREES (U.N.O.)·ALL POINT LOAD SUPPORTS (JACK STUDS) TO BE CARRIED THRU EACH FLOOR LEVELTO BEAR ON FOUNDATION, INSTALL BLOCKING IN FLOOR SYSTEM BELOW ALL POINTLOAD SUPPORTS·ALL WOOD IN CONTACT W/ CONCRETE TO BE PRESSURE TREATED WOOD·ALL DIMENSIONS ARE TO ROUGH FRAME (U.N.O.)·S.R.O. SIZES LISTED ARE THE FINISHED SHEETROCK OPENING WIDTH AND HEIGHT PERPLAN (EXAMPLE: 2680 OR 2/6x8/0 = 2'-6"x8'-0")·FLOOR BREAK INDICATES CHANGE IN FLOORING MATERIAL, REFER TO THESPECIFICATIONS FOR ACTUAL FLOORING MATERIALS SELECTED·REFER TO SPECIFICATION INFORMATION FOR ALL APPLIANCES & THE APPROPRIATEELECTRICAL OR GAS HOOK-UP REQUIREMENTS FOR EACH·REFER TO SPECIFICATION INFORMATION FOR ALL TUB AND SHOWER SURROUNDMATERIALS·REFER TO SPECIFICATION INFORMATION & CABINET SHOP DRAWINGS FOR KITCHEN &BATH CABINET LAYOUT, SIZES & FEATURES PER CABINET SUPPLIER·ALL BATHROOM FANS TO BE VENTED TO EXTERIOR·TOWEL BARS MOUNTED AT 54" AFF, TOILET PAPER HOLDERS MOUNTED AT 24" AFF·ALL PANTRY & LINEN CLST'S. TO RECEIVE WIRE SHELVING, (U.N.O.)·ALL CLOSETS TO RECEIVE (1) ROD & (1) WIRE SHELF (U.N.O.)·ALL WASHERS ON LEFT SIDE, ALL DRYERS ON RIGHT SIDE·AT ALL BATHROOM VANITIES, INSTALL WOOD STUD FRAMING SO ELECTRICAL OUTLETIS CENTERED ON VANITY.SCALE:3.11FIRST FLOOR PLAN1/4" = 1'- 0"SCALE:3.12GOURMET KITCHEN OPTION1/4" = 1'- 0"SCALE:3.13TILED SHOWER W/ BENCH OPTION1/4" = 1'- 0"-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ). 18" FLOOR TRUSS25/32" OSB SUBFL.BOTTOM OF TOP CHORDVAPOR BARRIERR-44 BLOWN INSULATIONEXTEND SHTG. TO5/8" DRYWALL CLG. (TYP.)CEILING(WINDWASH)MANUF. TRUSSES24" O.C.12PER PLANBATT INSULATION (R-20 MIN.)2x6 TOP & BOTTOM PLATES1/2" DRYWALL WALLS W/ 4 MIL. POLY (TYP.)7/16" OSB SHEATHING, TYP.VAPOR BARRIER2x6 STUDS 16" O.C.WALL CONST.SIDING PER SPEC. LEVELHOUSE WRAPROOF CONST.ASPHALT SHINGLES PER SPECS.WATERGUARD ICE BARRIER AT EAVESSOFFIT AND FASCIA PER SPEC. LEVEL7/16" OSB SHEATHINGINSULATION CHUTES15# FELT2x6 SUBFASCIARIM CONST. - R-20 MIN. 2x8 TR. SILL PLATE W/ A.B. (SEE SHT. S2)R-20 SPRAY FOAM INSULATION7/16" OSB SHEATHING(CANT. PLATE 1 1/2" TO ALIGNW/ 1/2" INSIDE SHEATHING)2" CERTI-STUD INSUL (R-10)STD. ENERGYHEEL HT.MIN. 6"6" GRAVEL FILL6 MIL POLY / LAPPED 12" 4" CONCRETE SLAB20x8 CONC. FTG.APPROX. GRADE8" POURED CONC. WALLFDN. WALL CONST."WATCH DOG" WATERPROOFING2 3/8" "WATCHDOG" (R-10)XP BOARD TO GRADEINTERIOR R-5 RIGID INSULATION7/16" OSB SHEATHING TYP.BATT INSULATION (R-20 MIN.)2x8 TOP & BOTTOM PLATESHOUSE WRAPVAPOR BARRIER2x8 STUDS 16" O.C. (LOOKOUT ONLY)WALL CONST.SIDING PER SPEC. LEVELWALKOUT WALL DETAILSEE PAGE A2 FOR NOTE:WINDOW FALL PROTECTION TOWITH R312.2.1BE PROVIDED IN ACCORDANCELENNAR WILL INSTALL A "PASSIVE RADON READY" SYSTEM.ALL BASEMENT SLABS WILL HAVE A MIN. 4" CLEAN AGGREGATE, COVERED BY 6 MILPOLY. THIS POLY WILL HAVE 12" LAP AT ALL SEAMS. ALL TEARS OR PUNCTURESWILL BE SEALED OR COVERED BY POLY. ALL OPENINGS WILL BE SEALED USINGPOLYURETHANE CAULK OR ELASTOMERIC SEALANT AT ALL OPENINGS. ALL SUMPBASKETS WILL HAVE SEALED LIDS.LENNAR WILL INSTALL A 3" GASTIGHT PVC PIPE, AND WILL BE CONNECTED TO THEDRAIN TILE SYSTEM. USING A "T" FITTING, INTO THE DRAIN TILE SYSTEM. WE WILLUSE THE SHORTEST ROUTE TO EXIT THE ROOF SYSTEM, WITH A MAX. OF (2) 90DEGREE ELBOWS. IN UNCONDITIONED AREAS, THE RADON EXHAUST PIPE WILL BEINSULATED WITH AN R4 SLEEVE. THIS PIPE WILL BE LABELED "RADON GAS VENTSYSTEM" AT ALL ACCESSIBLE LOCATIONS. ALSO, ALL RADON PIPES WILL BE LABELEDAT ALL FLOORS FOR FUTURE REFERENCE.AT ROOF EXIT LOCATIONS, WE WILL MAINTAIN A 10' DISTANCE TO ANY WINDOWLOCATION, 2' BELOW EXHAUST POINT AND ANY ADJACENT STRUCTURE. THELOCATION OF THE EXIT POINT, IN TRUSS AREA, WILL BE CLEAR OF ANYOBSTRUCTIONS WITHIN 24" HORIZONTALLY AND 36" VERTICALLY. LENNAR WILLINSTALL AN OUTLET AND PULL CHORD LIGHT FOR FUTURE EXHAUST FAN ADDITION.RADON NOTE:HOUSE WRAP CUTTING PATTERN12CUT HOUSE WRAPPER DIAGRAM.CUT UPPER FLAP AT 45FLEX WRAPWINDOW OPENINGWRAP TO SILL OF APPLY 10" FLEXUNDER HEAD INSTALL WINDOWINSTALL JAMBSTRIPS OVERINSTALLED WINDOWHOUSE WRAP FOLDHOUSE WRAP FOLDSTRIP UNDER UPPERINSTALL HEADUPPER FOLDAND TAPE OVERCUTOVER HEAD STRIPDROP UPPER FOLDTO SETTING WINDOWAPPY CAULK BEHINDWINDOW FINS PRIORHOLD UPPER FOLD OUT UNTIL FINAL STEPINSTALL, FOLD SIDEAFTER FLEX WRAPHOUSE WRAP FLAPSOVER FLEX WRAPAND TRIM / FASTENTAPETAPEWINDOW WRAP.CAP UNDERINSTALL DRIPDOWN EACH SIDE.BEND CORNERS3456789SEAMSSCALE:A4.11TYP. WALL SECTION3/8" = 1'- 0"SCALE:A4.12SECTION1/4" = 1'- 0"SCALE:A4.14HOUSE WRAP DETAIL AT WINDOWN.T.S.SCALE:A4.13SECTION1/4" = 1'- 0" HEADER1/2" GYPSUM BD.1/2" GYPSUM BD.WIN. OPNG.2x6 HEADER PLATEINSULATE1 1/4" RIM BOARD2x6 DOUBLE TOP PLATE2x6 SILL PLATESUBFL.INSULATE2" SPRAY6'-11 3/8" TO T.O. WIN. R.O.SUBFL. AT 8' CLG. 8'-0" TO SUBFL. AT 9' CLG.1x2 AT EA. SIDE OFWINDOW OPENINGSHEATHINGFOAM INSUL.FLOOR SYSTEM PER PLAN1/2" GYPSUM BD.TRUSS BTM. CHORDTOP PLATEDOUBLE WIN. OPNG.WIN. HDRS.SHEATHING2x6 HDR. PLATET.O. WIN. R.O.6'-11 3/8" TO SUBFL.INSULATEINT/EXT WALL INTERSECTIONINTERIOR WALL CORNER2x6 EXTERIOR WALL1/2" GYPSUM BOARD2x6 R.W. 2x4 R.W. 2x6 EXTERIOR WALL2x2 R.W. INSIDE CORNEROUTSIDE CORNERINSULATE STUDCAVITIES OF ALLCORNERS AND INTERSECTIONSOF OUTSIDE WALLSSIDING2x4 INTERIOR WALL 2x4 BACKINGAT MID HGT.2x4 INT. WALLSHEATHING(EXT. FIN. MAY VARY PER PLAN)PER PLANEXT. MAY VARYSHEATHING9'-0"PLYWD.ALUM. SOFFITW/ALUM.2 x 6 SPF1/2" OXBOARD SHEATHINGGABLEEND TRUSS(WHERE APPL.)2x6 FOR LOOK OUTSUSE SCRAP 2x4 ORNOTE:ENG'DFASCIADIM.2x4 INT. WALLBOARD1/2" GYPSUM5/8" GYPSUM BD.2x4 DOUBLETOP PLATE2x6 BACKINGBOTTOM CHORDOF TRUSSINT WALL2x2 NAILER3/4" PLYWOOD1/2" GYP. BD.FIRE STOP5/8" GYP. BD.I-JOISTDOUBLE TOP PLATEPER PLAN5/8" GYP. BD.1/2" GYP. BD.PER PLANHANGER(2) MICROLAM BEAMSHANGER1/2" GYPSUM BD.SUBFLOORNOTE:FOLLOW MFG'S NAILINGPATTERN FOR HANGERFLOORSYSTEMPER PLANFLOORSYSTEMPER PLANFLOOR SYSTEM PER PLAN1/2" GYPSUM BD.SUBFLOOR(2) 2 x HEADERS1/2" OSBDOUBLE TOP PLATESILL PLATESILL/ TILT TO OUTSIDEHEADER(1) 2X6 TRIMMER U.N.O. VARIES8'-1 1/8" or 9'-1 1/8" TYPICALVARIES7'-0" OR 8'-0" (MAIN FLOOR) / 6'-11 3/8" (2ND FLR.)(R.O.)(R.O.)ON FLOOR PLAN(REFER TO PLAN)FOR WATER DRAINAGERUN TRIMMERS TOBOTTOM OF HEADER(SEE PLAN)BOTT. PL.10"2x12 STRINGERS3'-0"10"7 3/4" MAX.(3) 2x12 STRINGERS5/8" TYPE "X" GYP.AT ENCLOSED USABLESPACE (TYPICAL)UNLESS NOTED OTHERWISE IN CONSTR. WORK ORDERPARTICLE BOARD TREADS & RISERS3"6 1/2" W. x 3/4" T.WOOD CAP5/8" TYPE "X" GYP.AT ENCLOSED USABLESPACE (TYPICAL)ALLOW 6'-8" MIN. HEADROOMNOTE:REFER TO SELECTIONS FOR REFER TO PLAN OR WORK ORDER FOR RAIL AND FINISH TYPE(S)NOTE: THIS DETAIL IS FOR FRAMING PURPOSES ONLY4"MAX.RAIL TYPE3/4" PLYWOOD1 1/4" RIMBOARDSUBFLOORFACE OF RISER3/4" PLYWOOD1 14"7 3/4" MAX.11 14"FLOORSYSTEMPER PLANMAX.MAX.1 14"11 14"MAX.MAX.2x4 TO EXTEND 1 1/2"BEYOND 2x AT EA. ENDCAULKNOTE:5 DEG.2 x W/BEV. TOP"Z" FLASHINGSMOOTH FINISH 2x4EXT. FINISH PER PLANSEE PLANVARIESROUGH OPENINGROUGH OPENINGSUBFLOORCRIPPLEHEADER PLATEDOUBLE TOP PLATE9'-1 1/8" OR 8'-1 1/8" TYPICAL STUDSNOTE: THIS DETAIL IS FOR FRAMINGPURPOSES ONLY, REFER TO SPEC'S. BOX NEWELSTARTER1 3/4" RIM BD.1/2" GYP.SUBFLR.PER PLANFLR. SYSTEM3'-0" FROM FIN. FLR.FOR RAIL & FINISH TYPES TREADPOSTSTONE CAPOR ROWLOCK BRICKFLASHING - CONT.CAULKSHEATHING15# FELT1" AIR SPACESTUD WALLSIDING PER PLANSLOPED TO DRAINSHEATHING ONCEDAR 5/4x BLOW UP DETAIL1 1/8"CAULK"Z" FLASHING"Z" FLASHING4"MINIMUM FINISH MTR'L.PER PLANPER PLANCAULK2x6 FRAMINGFINISH MTR'L.PER PLANWATER RESISTIVE BARRIERWIN. UNIT DIM.14"WIN. ROUGH OPENINGSHEATHINGWINDOW UNITGYPSUMSPRAY FOAM SIDINGTRANS.INSULATIONTRIMSTONE/BRICK CAPSLOPED TO DRAIN(FOR STONE CAP)CAULKTO BACK OF SILLSHEATHING15# FELT1" AIR SPACEFLASHING - CONT.FLASHING - CONT.(FOR BRICK CAP)TO BACK OF SILL2'-0"2x6 SPF MIN. ICE BARRIERVERT. TO ROOFW/ R20 MIN.2x6 STUD WALLON 4 MIL POLY1/2" GYPSUM BD.SOFFITSIDING PER PLANSHINGLES, 15# FELT, 48# BASESHEATHINGTRUSS BOT. CHORD5/8" GYPSUM BD.INSULATION BAFFLES (48" L.)ENG'D TRUSSES AT 24" O.C.R-49 INSULATIONDBL. TOP PLATEON 4 MIL POLYROOF VENTS AS REQUIREDSHEATHINGICE BARRIER6"MIN.HEEL HGT.ICE BARRIER TO END THIS POINTNOTE: ICE AND WATER SHIELD TO RUNENTIRE LENGTH OF ALL VALLEYS2 ROWS OF 24" TO INSURECOVERAGE PAST PLATE LINEEXTEND SHEATHING1 1/4" PAST END OF TRUSSFOR 6/12 PITCH ROOF.REDUCE OVERLAP PERSTEEPER PITCH TRUSSES.OVERLAP W/ FASCIAICE / WATER SHIELDBATT INS.5/8" FIRE-RATEDGYP. BOARDEXTERIORSHEATHINGWRB CONT. ONVERTICAL &HORIZONTALPLANES ATTUCKUNDER,TAPE ALL SEAMSR-20 SPRAYFOAM AT RIM6" DIA. R-4.2 INSULATEDFLEX-DUCT, HELD TIGHTTO FLOOR ABV.TYP. EXTERIORWALL: 2x6 STUDFRAMING W/ R-21BATT. INSULATIONTHERMOPANR-19 MIN. SPRAYFOAM INSUL.PER TABLE R402.1.1WRB CONTINUOUS ONVERTICAL AND HORIZONTALPLANES AT TUCKUNDER,TAPE ALL SEAMSTUCKUNDER FLOOR CAVITIESW/O HVAC BLOWN FULL W/ 11-7/8"FIBERGLASS L-77 INSULATIONI-JOIST FLRSYSTEMGARAGEHOUSEHOUSEELASTOMERICCAULK ATCORNER(BY INSULATORS)8" MIN.PVC SHOWER PAN LINER,DO NOT CUT, EXTEND UP WALL 8" MIN.CEMENT BOARD, OVER LINERCERAMIC TILEWOOD SUBFLOORGROUT SOLID W/ MORTARCERAMIC TILE, SLOPED1" VERTICAL TO DRAIN2-PIECE SHOWER DRAIN SYSTEMTILE SHOWER WALL & DRAIN DETAILTILE SHOWER PLATFORM DETAILCERAMIC TILE W/ BULLNOSED EDGE AT LIPCEMENT BOARD, OVER LINERWOOD SUBFLOOR(2) 2x4 SLEEPERS AT 8" O.CPVC SHOWER PANLINER, DO NOT CUT.CONTINUE OVERPLATFORM 12" MIN.GROUT SOLID W/ MORTARCERAMIC TILE, SLOPED1" VERT. TO DRAINCERAMIC TILEPLATFORM FLOOR1'-0" MIN.3/4" OSBTILE SHOWER CURB DETAILCEMENT BOARDTILE FLOORWOOD SUBFLOORCERAMIC TILE W/BULLNOSED EDGEBATHROOMSHOWER(2) 2x4 SLEEPERS AT 8" O.C3/4" OSB10"30 MIL PVC MEMBRANE, SEALALL SEAMS, CORNERS & EDGESW/ 35 MIL POLYETHYLENEBACKED SYNTHETIC BUTYLRUBBER ADHESIVE MEMBRANE4" MIN. AT GRADE2" MIN. AT HARD SURFACE W/ NO FOOTERGRADEMORTAR SCRATCH COATEXTERIOR SHEATHINGCULTURED STONE VENEER2 LAYERS WRBWIRE LATHMORTAR SETTING BEDWEEP SCREED, EXTEND MIN. 1" BELOWTOP OF FND. WALL2 LAYERS W.R.B. LAPPEDOVER WEEP SCREEDFRAMING HGT OF BOX PIER PER PLANPER PLAN4"(2) USP B88 CLIPS W/(36" H. MOST COMMON W/ RAILING)FINISH WIDTH IS PER PLAN(6) 3/8" x 1" LAG SCREWSTOP RAIL OF RAILING1/2" OSB SHEATHINGINSTALL ICE/WATER SHEILDBEHIND B88 CLIPS2X6 BACKER AT MID POINTBOTTOM RAIL OF RAILINGINSTALL 2x6, CLIPPEDFOR FLAT CLG. FINISHGYP. BOARD,FINISH PER PLANFLOOR SYSTEMPER PLAN5 12"2x4 STUD WALLNON-BEARINGN/A1FLASHING DETAIL3"= 1'-0"2NAILER DET.1"= 1'-0"3FLUSH BEAM1"= 1'-0"4DROP'D. BEAM1"= 1'-0"5EAVE/RAKE1"= 1'-0"8STONE SILL DETAIL1" = 1'-0"1411M. FLR. WIN. HDR.1" = 1'-0"12UPPER FLR. WIN. HDR.1" = 1'-0"13TYP. STUD LAYOUT1" = 1'-0"15DOOR FRAMING1" = 1'-0"16WINDOW FRAMING1" = 1'-0"19RAIL DETAIL1" = 1'-0"201x2 NAILER @ WINDOW3" = 1'-0"21TRIM DETAIL3" = 1'-0"10PIER W/ RAILING DTL.3/4" = 1'-0"6SOFFIT DETAIL1"= 1'-0"7STONE CAP1"= 1'-0"18STAIR FRAMING DETAILS1/2" = 1'-0"22TYPICAL OVERHANG DETAIL1" = 1'-0"23FLOOR ABV. GARAGE INSUL. DETAIL1" = 1'-0"24SERENITY SHOWER OPTION DETAILS1 1/2" = 1'-0"9STONE VENEER DTL.3/4" = 1'-0"17UNDER FIN. STAIR DTL1" = 1'-0" ELEC. R.I. TO JUNCTIONBOX FOR FUTUREOUTLET INSIDE CABINETDUPLEX CONVENIENCE OUTLETDUPLEX OUTLET ABOVE COUNTERWEATHERPROOF DUPLEX OUTLETHALF-SWITCHED DUPLEX OUTLETDUPLEX OUTLET IN FLOOR220 VOLT OUTLETWALL SWITCHTHREE-WAY SWITCHFOUR-WAY SWITCHCEILING MOUNTED INCANDESCENT LIGHT FIXTURERECESSED INCANDESCENT LIGHT FIXTURELIGHT FIXTURE WITH PULL CHAINFLOURESCENT LIGHT FIXTUREEXHAUST FANCHIMESSMOKE DETECTORTHERMOSTATELECTRIC PANELPCWPELECTRICAL KEY DUPLEX OUTLET (GROUND FAULT PROTECTED)GFIPRECESSED INCANDESCENT EYE BALL FIXTURECARBON MONOXIDE DETECTORELECTRIC VEHICLE CHARGER ROUGH-IN (OPTIONAL)LED FIXTURELMULTI-MEDIA JACKEVCMMTCMSDCHPLUGMOLD PM34ELEC. R.I. TO JUNCTIONBOX FOR FUTUREOUTLET INSIDE CABINETPMPMPM AND HEATING PIPE LOCATIONS AND WOOD FRAMING MEMBERS1. THIS ELECTRICAL PLAN MAY VARY DEPENDING UPON PLUMBINGSUCH AS JOISTS, TRUSSES AND STUDS.GENERAL NOTES ELECTRICAL AND/OR GAS HOOK-UP REQUIREMENTS, THIS INCLUDES2. REFER TO SPECIFICATION INFORMATION FOR ALL APPLIANCEBUT IS NOT LIMITED TO WASHER, DRYER, RANGE/COOKTOP,MICROWAVE, OVEN AND/OR ADVANTIUM (WHERE APPLICABLE),DISHWASHER AND REFRIGERATOR.5. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & RECEPTACLESAT THE FOLLOWING HEIGHTS ABOVE FINISH FLOOR:REQUIREMENTS OF ALL GOVERNING CODES.AS REQUIRED BY NATIONAL ELECTRIC CODE (NEC) AND MEETING THE4. PROVIDE AND INSTALL GROUND FAULT CIRCUIT-INTERUPTERS (GFI)AND MEETING THE REQUIREMENTS OF ALL GOVERNING CODES.TELEVISION.........14"TELEPHONE........14"OUTLETS.............14"SWITCHES...........42"AS REQUIRED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)3. PROVIDE AND INSTALL LOCALLY CERTIFIED SMOKE DETECTORSSCALE:E1.14GOURMET KITCHEN ELECTRICAL1/4" = 1'- 0"SCALE:E1.11FIRST FLOOR PLAN ELECTRICAL1/4" = 1'- 0"SCALE:E1.12UNFINISHED LOWER LEVEL ELECTRICAL PLAN1/4" = 1'- 0"SCALE:E1.13WALKOUT LOWER LEVEL ELECTRICAL PLAN1/4" = 1'- 0" 1/2" DRYWALL FIREPLACE FLUE FIREPLACE BOX 8 1/4"8 1/2"5 1/2"1 1/2"3/4"VERIFY DIST. TO COMBUSTIBLES w/ MANUFACTURER'S SPECIFICATIONS.24 24 3/4"3/4" 4 2 2 6 1x10 TRIMMED 2x4 1x4 3 1/2" 1/2"1x624 1'-0 1/2" 1'-8" 3'-6" R.O.1'-4"5'-11" ALLOW 16" SPACE FOR VENT DUCT FRAMED FRAMED1'-8"1'-10 1/2"FIN.1'-2 1/2"1'-2 1/2"8"MANTEL5'-2"SL-7 GAS FIREPLACE R.O. 42" W. x 38 1/4" H. x 16 1/4" D. 7 1/2" FRAMED912"2'-10 1/2"912"9'-0"7 1/2" FRAMED 91 2"3'-1" 2" APPLIED STONE VENEER 812"5'-11" FRAMED 91 2" 5'-6" MANTEL 1/2" REVEAL AT ALL SIDES OF F.P. 4'-8" FACE OF DRYWALL 2" STONE RETURN2" STONE RETURN 6'-0" FINISHED 4"3'-6" R.O. FRAME R.O. FOR F.P. BOX AT 8-7/8" ABOVE FLOOR TO FACE OF DRYWALL TO FACE OF DRYWALL TOP OF MANTEL EQ.EQ.8"8"8"8" CL EQ.EQ. CL CEILING RECEPTACLE TECH. TUBE2x10 BLOCKING BACKER 2x42x42x42x42x4GAS FIREPLACE BOX FRAMING PER PLAN 4'-1" R.O.1'-4"5'-11" FRAMED ALLOW 16" SPACE FOR VENT DUCT FRAMED1'-8"1'-10 1/2"STONE FINISH512" 5'-4" FINISHED 9'-0"2" APPLIED STONE VENEER 5'-0" TO FACE OF DRYWALL 2" STONE RETURN 2" STONE RETURN 5'-11" FRAMED 4'-11" MANTEL SHELF 5'-0" FRAMED2"FRAME R.O. FOR F.P. BOX, 2" ABOVE SUBFLOOR 1/2" REVEAL AT ALL SIDES OF F.P. COSMO 42" GAS FIREPLACE R.O. 49"W x 32 3 4"H x 17 3 4"D 614"1'-8"59"L.x8"D.x2 1/2"H. MANTEL SHELF 4'-5"2x4 FRAMING 2" APPLIED STONE VENEER 512"512"512" 5'-1" R.O. 5'-11" FRAMED7 1/4"6'-0" FINISHED 9'-0"5'-1" R.O.5" FRAMED 5" FRAMED1'-6"1'-7 3/4"R.O.5'-11" FRAMED 1/2" DRYWALL FINISH ALLUSION PLATINUM 60 ELECTRIC FIREPLACE 4'-6"T.O. OPT. MANTLE2x8 FRAMING, FLOOR TO CLG 1/2" DRYWALL FINISH 4'-11" OPTIONAL MANTLE SHELF OPTIONAL 59"L.x8"D.x2 1/2"H. MANTEL SHELF SEE SELECTIONS 1/2" DRYWALL FINISH BACK TO WALL 5'-1" R.O. 5'-11" FRAMED7 1/4"6'-2" FINISHED STONE 9'-0"5'-1" R.O.5" FRAMED 5" FRAMED1'-6"1'-7 3/4"R.O.1" APPLIED STONE VENEER 5'-11" FRAMED ALLUSION PLATINUM 60 ELECTRIC FIREPLACE 4'-6"T.O. OPT. MANTLE SH.5'-11" FRAMING 1" STONE VENEER 1/2" DRYWALL 2x8 FRAMING, FLOOR TO CLG 1/2" DRYWALL 1" STONE VENEER RETURN TO WALL 4'-11" OPTIONAL MANTLE SHELF OPTIONAL 59"L.x8"D.x2 1/2"H. MANTEL SHELF SEE SELECTIONS 1" STONE VENEER 1/2" DRYWALL 5'-1" R.O. 5'-11" FRAMED7 1/4"9'-0"5'-1" R.O.5" FRAMED 5" FRAMED1'-6"1'-7 3/4"R.O.1/2" DRYWALL 5'-11" FRAMED 8mm DEKTON FINISH ALLUSION PLATINUM 60 ELECTRIC FIREPLACE 4'-6"T.O. OPT. MANTLE2x8 FRAMING, FLOOR TO CLG 1/2" DRYWALL 8mm THICK DEKTON FINISH 8mm THICK DEKTON FINISH 5'-11" FRAMING 4'-6"DEKTON SEAM4'-11" OPTIONAL MANTLE SHELF OPTIONAL 59"L.x8"D.x2 1/2"H. MANTEL SHELF SEE SELECTIONS 8mm DEKTON 1/2" DRYWALL 8mm DEKTON 1/2" DRYWALL 5'-1" R.O.1'-7 3/4" R.O.CEILING RECEPTACLE TECH. TUBE2x10 BLOCKING BACKER 8"8"8"8" CL 6'-6"EQ.EQ. CL 1'-6"INSTALL OUTLET ON DED. CIRCUIT NEAR BOTTOM RIGHT OF FP UNIT 2x STUDS, SIZED PER FLOOR PLAN 3'-6".R.O.6'-0" FINIS H E D 1'-3"1'-3"5'-2"SL-7 GAS FIREPLACE R.O. 42" W. x 38 1/4" H. x 16 1/4" D. 7 1/2" FRAMED9 1/2"2'-10 1/2"9 1/2"7 1/2" FRAMED 91 2"3'-1" 2" APPLIED STONE VENEER8 1/2"5'-11" FRAMED 91 2" 5'-6" MANTEL 6'-0" FINISHED 1/2" REVEAL AT ALL SIDES OF F.P.9'-0"FRAME R.O. FOR F.P. BOX AT 8-7/8" ABOVE FLOOR TO FACE OF DRYWALL TO FACE OF DRYWALL VENT LOCATION PER PLAN 4'-3 1/4"45°TO FRAMING4'-1" FRAMING R.O.6'-0" FINIS HE D4'-3 1/4"5'-0"512"512"4" VENT LOCATION PER PLAN 45°5'-4" FINISHED 9'-0"2" APPLIED STONE VENEER 5'-0" TO FACE OF GYP. BD. 2" STONE RETURN 2" STONE RETURN 5'-11" FRAMED2"FRAME R.O. FOR F.P. BOX, 2" ABOVE SUBFLOOR 1/2" REVEAL AT ALL SIDES OF F.P. COSMO 42" GAS FIREPLACE R.O. 49"W x 32 3 4"H x 17 3 4"D 614"1'-8"59"L.x8"D.x2 1/2"H. MANTEL SHELF 4'-11" MANTEL SHELF 4'-5"TO FRAMINGPAGE DESCRIPTION:PAGE NO.: PLAN NO. FIREPLACE FIREPLACESFIREPLACES _1-10-2019ISSUE FOR CONSTRUCTION6-01-2024Q3 2024 PLAN REVISIONSREVISIONS FOUNDATION DETAILAT FOOTING STEP LOCATIONS1S1DescriptionDateRevisionProject Number:Date:S11Sheets: of 2Print Name:Signed: License Number:Nick Hanson46665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.January 1, 20244.0011-1-242024 FOUNDATION GUIDEWALL SECTIONWALKOUT WALL CONDITION2S1WALL SECTIONLOOKOUT WALL CONDITION3S1WALL SECTIONEXTERIOR UNBALANCED FILLCONDITION4S1WALL SECTIONFULL HEIGHT WALL CONDITION5S1REBAR TABLE6S1SITE ADDRESS:City:State:Zip:MNCOPYRIGHT HANSON GROUP LLC 2024©DRAWING USE GUIDELINES AND LIMITATIONSTHE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THISPACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE.THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THEPROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS.THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT INACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEWAND INSPECTIONS.LIMITATIONS1. BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOPOF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT).2. STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT.3. OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITESPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED.4. STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST ORSTRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED.5. EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS.6. ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURALENGINEERING DOCUMENTS.COLD WEATHER GUIDELINES:1. THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILLADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONALCEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED ATTEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F.2. DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHENPOSSIBLE.3. DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS ISRECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR INCONTACT WITH FROZEN MATERIALS.4. REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE.5. BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLSWHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALLWHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F.**THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHERREQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE.MATERIALSCONCRETE WALLS: F'c = 3000 PSI @ 28 DAYSMIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIERCONCRETE FOOTINGS: F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDESA WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE.AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX.REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40#5+ BARS - ASTM A615 GRADE 60TREATED SILL PLATE: SYP GRADE #2 OR BETTERALLOWABLE SOILBEARING PRESSURE 1,500 PSF MINIMUMGENERAL NOTES1. DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVESTRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLYSUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESSADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERALCONTRACTOR.2. STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS.3. 112" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS.4. STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIPFOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE.5. PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS.6. SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEETUNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED.7. BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, ANDINSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTEDOTHERWISE.8. ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALLTHICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS.9. REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BARDIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET.10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVERIS ACHIEVED ON ALL SIDES.11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS.12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN.VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS.13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINORFORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS.14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONSARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALLCORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS INLENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELSMAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHTFOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOADTRANSFER OVER A SILL PLATE OVERHANG CONDITION.15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1.16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITHTHE MANUFACTURER'S REQUIREMENTS.17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS.18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL ANDDIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICALREINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED,BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDINGIS ACHIEVED.19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING.MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS.20.THESE DRAWINGS ARE INTENDED TO BE A LIMITED COMPONENT DESIGN TO RESIST LATERAL SOILPRESSURES FOR SINGLE FAMILY RESIDENCES. VERTICAL LOADS AND FOOTING DESIGNS ARE TO BE THERESPONSIBILITY OF THE BUILDING DESIGNER. NO SUPPLEMENTAL ENGINEERING OR COMPONENT DESIGNFOR THE FOUNDATION SYSTEM SHALL BE INCLUDED WITH THIS PACKET WITHOUT THE PRIOR REVIEW ANDCONSENT OF THE HANSON GROUP.EQUIVALENT REBAR TABLEFOR BUNDLED HORIZONTAL BARS(2)#4 = (1)#6(3)#4 = (2)#5(3)#5 = (2)#6GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10" 12"8"10" 12"8"10" 12"NONE NONE NONENONE NONENONE NONENONE NONENONENONENONENONENONENONENONENONE NONENONE NONENONENONENONENONENONENONENONENONENONENONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONENONE NONE NONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24" 24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)(2) #4 HORIZONTAL BARSBOTH TOP & BOTTOMEXTENDED AT LEAST 24"BEYOND EACH END OF STEPSTABLE BANKHIGH FOOTING MAY BEEXTENDED PROVIDEDBARS ARE PLACED ASSHOWNHORIZ. BARSTOP & BOTTOM6" MIN THICK CONCRETEFOUNDATION, SEE OTHERDETAILS FOR MORE INFOOPTIONAL CONTROL JOINTAT EACH END OF STEP72" MAX SPANEQ.EQ.24" MINDETAIL B3" MIN TYPCONCRETE STRIPFOOTING11BDETAIL A36" MINSTEP2 x STEPSTEP NOTE:DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEPLOCATIONS SHOWNREAR FROST WALLLOOKOUTWALLFULL HEIGHTWALLGARAGE FROSTWALLELEVATIONSHOWN FORREPRESENTATIONPURPOSES ONLY-MAY NOT APPLYELEVATIONSTEP SPACING REQUIREMENTSATYP.6"MIN.WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAYFROM FOUNDATIONOPTIONAL STEM WALLMINIMUM THICKNESS TOMATCH SILL PLATESILL PLATE TO MATCHFRAME WALL ABOVE16" MAX FOR 4" THICK STEM24" MAX. FOR 6" THICK STEMSLAB-ON-GRADE BY OTHERS(1) #4 x CONTINUOUSHORIZONTAL BAR ATTOP OF WALL6" MIN. C.I.P. CONCRETEFOUNDATION WALLUNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1#4x2'-0" DOWELS @ 72" O.C. MAX(5" MIN. EMBED) DOWELS ARENOT REQUIRED IF BACKFILL ISPLACED EQUALLY ON BOTHSIDES IN LIFTS NOT TO EXCEED24"-ALTERNATE EACH SIDE6"MIN.3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN.EMBED) CENTERED IN WALL @48" O.C. (SAND SOIL)OR 36" O.C. (SANDY-CLAY SOIL)OR 24" O.C. (CLAY SOIL)DOWELS MUST BE WET SET ORDRILLED AND EPOXY GROUTED6" MIN. THICK C.I.P.CONCRETEFOUNDATION WALLSLOPE GRADE AWAYFROM FOUNDATION12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORS(1) #4 x CONTHORIZONTAL BARAT TOP OF WALLFRAMING & SILLPLATE BY OTHERSSLAB-ON-GRADEBY OTHERSUNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1(18" MIN WIDTH FOR CLAYBACKFILL OR 16" MIN WIDTH IF2'-6" MAX UNBALANCED BACKFILL)SCOPE OF DRAWINGS:THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED ANDCERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESEDRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P.CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANTTO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR.THESE DRAWINGS EXPIRE ON DECEMBER 31, 2024.6"MIN. CLEAR HEIGHT BACKFILL HEIGHT112" CLEARUNREINFORCED CONCRETESTRIP FOOTING PER CODEOR BY BUILDING DESIGNER,AS AN ALTERNATIVE GUIDEUSE TABLE SHOWN BELOW8" MIN. C.I.P. CONCRETEFOUNDATION WALL-SEEREBAR TABLE 6/S1 FORVERTICAL REBARANCHOR BOLTS SEE WALLANCHOR INFO ON 2/S2FLOOR TO SILLCONNECTION SEE 1/S2WOOD FLOORSYSTEM BY OTHERSSLOPE GRADE AWAYFROM FOUNDATION2x6 MIN SILL PLATECLEAR HEIGHT OF 8'-0" OR LESS(2)#4xCONT. HORIZONTAL BARSCLEAR HEIGHT OF 8'-0" OR MORE(3)#4xCONT. HORIZONTAL BARSCONCRETESLAB-ON-GRADEPLACED TIGHT TOFOUNDATION WALL#4x2'-0" DOWELS @ 72" O.C.MAX (5" MIN. EMBED)GENERAL STRIP FOOTING SIZE GUIDESOILONE-STORY STRUCTURETWO-STORY STRUCTURE2000 PSF16" WIDE x 8" THICK20" WIDE x 8" THICK1500 PSF20" WIDE x 8" THICK26" WIDE x 8" THICKTHIS TABLE IS A GENERAL FOOTING SIZE GUIDE FOR TRIBUTARY UNIFORM LOADING ONLY BASED ONMAXIMUM 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS AND IS TO BE VERIFIED BY HOME DESIGNER. FURTHERCONSIDERATION IS TO BE TAKEN BY HOME DESIGNER FOR VENEER WEIGHT, WALL THICKNESSES OVER 10",AND FLOOR AND ROOF DEAD LOADS OVER 15 PSF. CONCENTRATED LOADS FROM GIRDER TRUSSES, BEAMS,HEADERS, ETC. ARE TO BE ACCOUNTED FOR AND SIZED INDEPENDENTLY OF THIS GUIDE BY OTHERS.6'-0" MAX WOOD FRAMINGABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAY FROMFOUNDATION AT A GRADUAL 2%SLOPE PER GENERAL NOTE 6SILL PLATE TO MATCHFRAME WALL ABOVE#4 x CONTINUOUS HORIZONTALBARS @ 24" O.C. TYP.OPTIONAL 2" RIGID INSULATION ONINSIDE FACE AND UNDERSLAB-ON-GRADE FOR 24" MIN.UNREINFORCED CONCRETESTRIP FOOTING SEE 5/S1(DROP FOR FROST ASREQUIRED PER SITE DESIGN)#4x2'-0" DOWELS @ 48" O.C.MAX (5" MIN. EMBED)(1) #4 x CONTINUOUS HORIZONTALBAR AT TOP OF WALLOPTIONAL SLAB LEDGECONCRETE SLAB-ON-GRADE8" MIN. C.I.P. CONCRETEFOUNDATION WALL#4 x 5'-0" HOOKS @ 24" O.C.EMBEDDED IN FOUNDATIONWALL & CAST INTO SLAB(MAY REDUCE 2'-0" LEG LENGTH& DRILL IN & EPOXY 8" MIN.INTO FOUNDATION WALL)3'-0"NO HOOKS @ 3'-0" OR LESS GRANULAR MATERIAL (SAND)DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0"#5 VERTICAL BARS @ 24" O.C.CENTERED IN WALL TO AID INTHE REDUCTION OF CRACKINGAND BACKFILLING ISSUES PRIORTO TOP OF WALL PINNINGCONTRACTOR IS TO PROVIDETEMPORARY TOP OF WALLBRACING UNTIL GARAGESLAB-ON-GRADE IS IN PLACE(HOOKS INTO GARAGE SLABPROVIDE REQUIRED TOP OFWALL LATERAL SUPPORT)2'-0"8'-0" OR LESS9'-0" MAX.10'-0" MAX.5851 Cedar Lake RoadSuite 202St. Louis Park, MN 55416Tel 612-708-3572www.hansongroupmn.com.GPPCT%QTRQTCVKQPVJ#XG05WKVG2N[OQWVJ/0 COPYRIGHT HANSON GROUP LLC 2024©DescriptionDateRevisionJanuary 1, 2024Project Number:Date:4.001S22Sheets: of 2Print Name:Signed: License Number:Nick Hanson1-1-2446665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.CONNECTION INFOTOP OF WALL CONNECTION TOFLOOR SYSTEM1S2BRICK LEDGE INFO5S2WALL SECTIONAT WINDOW WELL LOCATIONS6S2STOOP INFO7S2WALL ANCHOR INFOANCHOR BOLT AND ALTERNATIVESPACING2S2BLOCKING DETAILFLOOR JOIST CONDITION3S2BLOCKING DETAILFLOOR TRUSS CONDITION4S2SITE ADDRESS:City:State:Zip:MNVENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATIONWALL SEE 5/S1WOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS16" HIGH MAX x6" THICK MINSTEM6"MINWOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS6" MIN THICK STEM#4 DOWELS @ 36" O.C.EMBEDDED 24" INTOLOWER WALLFOUNDATIONWALL SEE5/S1VENEER ORSLAB-ON-GRADEBY OTHERS12"VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 2/S1 OR 3/S1FRAMING BYOTHERS16" HIGH MAXx 4" THICK MINSTEMTHICKNESS TOMATCH SILLPLATE6"3'-0" MAX VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 4/S1SLAB-ON-GRADEFRAMING BYOTHERS6" MIN THICKSTEMDETAIL @ HIGH GRADESIM @ NON-BEARINGDETAIL @ LOOKOUTSIM @ FROST WALLDETAIL @ FROST WALLSw/ LOW GRADEDETAIL @ LOW GRADESIM @ NON-BEARING112"CLEARMINMAX#4 DOWELS @36" O.C.EMBEDDED 24"INTO LOWERWALL (CENTERIN STEMWALL)6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICKx 2"Ø OR SQUARE WASHER SEE 2/S2FOR SPACING (7" EMBED MIN)-METAL STRAP ANCHORS TO BEINSTALLED AT MANUFACTUREREQUIVALENT SPACINGFLOOR SYSTEM, TYPE,SIZE, AND SPACING TO BEDETERMINED BY OTHERSRIM BOARD OR BRACINGMATERIAL BY OTHERS2x6 SILL PLATE MINIMUMFLOOR TO SILL CONNECTION ATEACH MEMBER SEE TABLE BELOWWASHER TO BE COUNTERSUNKFLUSH w/ TOP OF SILL PLATESEE FULL HEIGHT WALL SECTIONON 5/S1 FOR FOUNDATION WALLREQUIREMENTSSLOPE GRADE AWAYFROM FOUNDATIONMINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS****BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)FLOOR MEMBERSPACING16"19.2"A(4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBERSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)24"16"19.2"24"16"19.2"24"AAAAAAABAABBBBBCCCDDDDDDDCCONNECTION A(4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC ATEACH MEMBERCONNECTION CCONNECTION D(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ**OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS*ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS72"* 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWNSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS72"72"72"72"72"72"72"72"72"72"72"72"48"60"72"48"60"72"36"48"72"36"36"72"72"72"48"24"24"ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS**ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/S1)BACKFILL HEIGHT(SEE 5/S1)7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS48"** APPLIES TO 12"Ø EXPANSION BOLT w/ 6" EMBED, 12"Ø SELF-CUTTINGANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHORSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS60"72"30"36"72"18"24"42"72"72"24"18"20"24"18"24"24"30"42"16"12"14"16"12"16"36"36"N/AN/ASLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONNOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER.WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES.* FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES,FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE.** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH.*** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s.****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE ASTRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE.2x8 SILL PLATE TO BE USED w/MAXIMUM OF 112" OVERHANG(MAINTAIN 234" EDGE DISTANCETO BOTH CONCRETE AND INSIDEOF SILL PLATE) - VERTICAL LOADTRANSFER BY SUPPLIERNAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR@ BLOCKING SEE 1/S22 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWNOR SHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE 2/S2 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE 1/S22 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAYFROM FOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1. MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2. NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3. BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4. BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5. HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE 2/S2 FOR SPACING OFBLOCKING SYSTEM SHOWN10'-0" MAX 3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB 1'-6" MIN 3'-0" EACH WAY MIN112" TYP SLOPE GRADE AWAYFROM FOUNDATION#4 HORIZONTAL BARS @12" O.C. CENTERED INWALLS LAP AROUNDCORNERS AND HOOKINTO FOUNDATION WALL@ EACH SIDE (REFER TO5/S1 FOR HORZ. BARREQUIREMENTS w/ 8"C.I.P. WALLS)6" MIN C.I.P.CONCRETE WALL#4 VERTICAL BARS @EACH OUTSIDECORNER OF WELL(1)#4 x2'-0" DOWEL @EACH OUTSIDECORNER OF WELL (5"MIN EMBED)12" WIDE x 8" THICK MINSTRIP FOOTING(1) #4 HORIZONTALBAR AT TOP OF WALL(2) #4 HORIZONTAL BARSTOP & BOTTOM OFLINTEL EXTEND 24" MINPAST OPENING EACHEND (WOOD OR STEELOPTION BY OTHERS)WALL BEYONDPLACE (2) #4 VERTICALBARS FULL HEIGHT ANDONE ANCHOR w/IN 12" OFOPENING EACH END8" MIN C.I.P.CONCRETE WALLSLAB-ON-GRADEUNREINFORCED CONCRETESTRIP FOOTING SEE FULLHEIGHT WALL SECTION 5/S1LOOKOUTWALLSEE 3/S1GRANULARMATERIAL(SAND)SLOPEWINDOW WELLLADDER/ESCAPEMEANS BYOTHERS5'-0" EACH WAY MAXFLOOR SYSTEM BY OTHERS(DO NOT PLACE GIRDERS ORBEAMS OVER CONCRETE LINTELDESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL ATTHE DISCRETION OF THE BUILDER FOR ADDITIONALFROST PROTECTION AS REQUIRED PER SITE DESIGN6"MIN.BACKFILL HEIGHT (NOT TO EXCEED 10'-0")SEE 5/S1 FOR TYPICALFOUNDATION WALL &FOOTING CONSTRUCTIONMAINTAIN MIN. 6" WIDESTEMWALL WITHEXTERIOR LEDGEWOOD FLOORSYSTEM BY OTHERSBACKFILL BELOW EXTERIORSTOOP SLABS WITH COMPACTEDGRANULAR MATERIAL TO FROSTDEPTH (4'-0" MINIMUM)FLASHING &WATERPROOFINGBY OTHERSSTOOP SLAB BY OTHERS* SEE 1/S2 FOR FLOORTO SILL CONNECTION112" CLEARBUILD UP w/ RIGIDINSULATION BELOW SLABTO MAINTAIN 10'-0" MAX.BACKFILL HEIGHT ASREQ'D OR PROVIDE SITESPECIFIC ENGINEERING(MAY SUBTRACT 6" FOR USE IN TABLE LIMITS FOR SANDY CLAY & CLAY SOILS DUE TO GRANULAR FILL BELOW STOOP SLAB) * MODIFIED CLEAR HEIGHT* SEE REBAR TABLE 6/S1FOR VERTICAL REBAR* SEE 2/S2 FOR ANCHOR BOLTS* FOR REBAR TABLE 6/S1, FLOOR TO SILL CONNECTION TABLE 1/S2, AND ANCHOR BOLT TABLE 2/S2USE MODIFIED CLEAR HEIGHT OF 9'-0" IN TABLES FOR BACKFILL HEIGHTS UP TO 8'-6" ANDUSE MODIFIED CLEAR HEIGHT OF 10'-0" IN TABLES FOR BACKFILL HEIGHTS UP TO 9'-6"(MAY REDUCE BACKFILL HEIGHT BY 6" FOR USE IN TABLE LIMITS FOR SANDY CLAY AND CLAY SOILS)8'-0" OR LESS9'-0" MAX.10'-0" MAX.8'-0" OR LESS9'-0" MAX.10'-0" MAX.8'-0" OR LESS9'-0" MAX.10'-0" MAX.5851 Cedar Lake RoadSuite 202St. Louis Park, MN 55416Tel 612-708-3572www.hansongroupmn.com.GPPCT%QTRQTCVKQPVJ#XG05WKVG2N[OQWVJ/0 UFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel.FLIPPED FLIPPED 160,000 X X 66000 768 240 375 375 -183 3724 558 558 155 78 4 wrightsoft• Project SummaryEntire House Elander Mechanical Inc 645 Shenandoah Drive, Shakopee, MN 55379 Job: EV4F Date: 2024By: Kati Printon Plan: Salem W / Basement Pro·ect Information For: Lennar Corp Notes: Desi n Information Weather: Minneapolis-St Paul lnt'I Arp, MN, US Winter Design Conditions Outside db -15 °F Inside db 70 °F Design TD 85 °F Summer Design Conditions Outside db 88 °F Inside db 75 °F Design TD 13 °F Daily range M Relative numidity 50 % Moisture difference 31 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 39177 Btuh Ducts 1947 Btuh Central vent (SER=50% 149 cfm)6768 Btuh Heat recovery Humidification O Btuh Piping O Btuh Equipment load 47892 Btuh Infiltration Method Simplified Semi-tight 0 Construction quality Fireplaces Area (ft2) Volume (ft3) Air changes/hour Equiv. AVF (cfm) Heating 3724 20484 0.19 65 Cooling 3724 20484 0.10 34 Heating Equipment Summary Make Lennox Trade LENNOX Model ML 193UH070XE36B-* AHRI ref 202568879 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 93 AFUE 66000 Btuh 63000 Btuh 50 °F 1181 cfm 0.029 cfm/Btuh 0.80 in H2O Structure Ducts Central vent (SER=50% 149 cfm) Heat recovery Blower Use manufacturer's data Rate/swing multiplier Equipment sensible load 17911 Btuh 1420 Btuh 1027 Btuh 0 Btuh n 0.93 18913 Btuh Latent Cooling Equipment Load Sizing Structure Ducts Central vent ( 149 cfm) Heat recovery Equipment latent load 1705 Btuh 52 Btuh 3080 Btuh 4837 Btuh Equipment Total Load (Sen+Lat) 23750 Btuh Req. total capacity at 0.81 SHR 1.9 ton Cooling Equipment Summary Make Lennox Trade LENNOX Cond ML 14XC1S030-230A** Coil CX35-36B++ TOR AHRI ref 9148954 Efficiency 11.5 EER2,13.8 SEER2 Sensible cooling 22720 Btuh Latent cooling 5680 Btuh Total cooling 28400 Btuh Actual air flow 947 cfm Air flow factor 0.049 cfm/Btuh Static pressure 0.80 in H2O Load sensible heat ratio 0.81 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ,.:S:_ � �.!;��-�!,.�-�-!:!'."' Right-Suite® Universal 2023 23.0.03 RSU13410 ACcr,.., ... Folder\Lennar EV4F Salem Basement 4 season.rup Cale = MJ8 Front Door faces: N 2024-Jul-1 13: 32: 27 Page 1 20079 Gambit Pass Date Certificate Posted X Passive (No Fan ) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here X R-15 X X X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X X Not applicable, all ducts located in conditioned space X Not required per mech. code Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:66,000 Capacity in Gallons:Other, describe: AFUE or HSPF% 93% Cfm's " round duct OR " metal duct X Not required per mech. code Passive X Low: Other, describe: Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Duct system air tightness: Heating or Cooling Ducts Outside Conditioned Spaces Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Describe other insulated areas Building envelope air tightness: Windows & Doors Average U-Factor (excludes skylights and one door ) U: 0.31 Solar Heat Gain Coefficient (SHGC):0.29 R-value MECHANICAL SYSTEMS Make-up Air Select a Type Appliances Heating System Domestic Water Heater Cooling System Natural Gas Natural Gas Electric RU160iN ML14XC1S030 Fuel Type Manufacturer Lennox Rinnai Lennox Model ML193UH070XE36B 14 Location of duct or system: Rating or Size Tankless Output in Tons:2.5 Efficiency SEER /EER Residential Load Calculation Heating Loss Heating Gain Cooliing 47,892 18,913 23,750 MECHANICAL VENTILATION SYSTEM Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Combustion Air Select a Type Select Type Heat Recover Ventilator (HRV) Capacity in cfms:155 MN License Number Lennar BC001413 THERMAL ENVELOPE RADON CONTROL SYSTEM Type: Check All That Apply Insulation Location Total R-Value of all Types of InsulationNon or Not ApplicableFiberglass, BlownFiberglass, BattsFoam, Closed CellFoam Open CellMineral FiberboardRigid, Extruded PolystyreneRigid, IsocynurateNew Construction Energy Code Compliance Certificate Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel.7/12/2024 Mailing Address of the Dwelling or Dwelling Unit City Lakeville20079 Gambit Pass Name of Residential Contractor Below Entire Slab Foundation Wall Perimeter of Slab on Grade Rim Joist (1st Floor) Rim Joist (2nd Floor+) Wall Ceiling, flat Interior R5 + R10 Exterior Interior Interior Balanced Ventilation capacity in cfms:Mech Room Capacity continuous ventilation rate in cfms: Total ventilation (intermittent + continuous) rate in cfms: 78 High: Energy Recover Ventilator (ERV) Capacity in cfms:High: Location of duct or system: 000000Builders Associaton of Minnesota version 101014 NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.”(NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 20079 Gambit Pass US Home LLC dba Lennar Jesse Schwarzrock 612-346-2648 Jesse.Schwarzrock@Lennar.com Residential Development 57174 Chad Johnson Stantec 651-325-6860 chad.johnson@stantec.com University of Minnesota 5/31/23 7/12/2024Kurt NiskaDigitally signed by Kurt Niska Date: 2024.07.12 14:25:56 -05'00' 7/15/24 X PM