Loading...
HomeMy WebLinkAboutLV24-00150 - APPROVED-Solar PlansConcept Approval ONLYSubject to Field Inspection Inspector Date 2015 MN Bldg Code 09/26/2024jnuetzman 3����� 4 wp470 21.0 w sq-ft α EXPERIENCE PERFORMANCE ELIGIBLE LEAD-FREEROHS COMPLIANT Efficiency22.6% COMPACT PANEL Size 9 A module Current compatible with MLPE rec Alpha® Pure-RX Series Product Specifications REC Solar PTE. LTD.20 Tuas South Ave. 14 Singapore 637312post@recgroup.com www.recgroup.com Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. REC Alpha Pure-RX Series Product SPECIFICATIONS Available from: GENERAL DATA Cell type:88 half-cut bifacial REC heterojunction cells with lead-free, gapless technology Glass:0.12 in solar glass with anti-reflective surface treatment in accordance with EN 12150 Backsheet:Highly resistant polymer Frame:Anodized aluminum (black) Junction box:4-part, 4 bypass diodes, lead-free IP68 rated, in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4 (12 AWG) in accordance with IEC 62852, IP68 only when connected Cable:12 AWG solar cable, 66.9 + 66.9 in in accordance with EN 50618 Dimensions:68.0 x 48.1 x 1.2 in (22.4 sq-ft) Weight:51.6 lbs Origin:Made in Singapore Measurements in inches 85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 LOW LIGHT BEHAVIOUR STC NMOTCERTIFICATIONS IEC 61215:2021, IEC 61730:2016, UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance ISO 11925-2 Ignitability (EN 13501-1 Class E) IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) IEC 62321 Lead-free acc. to RoHS EU 863/2015 UL 61730 Fire Type 2 ISO 14001, ISO 9001, IEC 45001, IEC 62941 Lead-Free WARRANTY Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% The REC ProTrust Warranty is only available on panels purchased through an REC Certified Solar Professional installer. Warranty conditions apply. See www.recgroup.com for more details. DELIVERY INFORMATION Panels per pallet:33 Panels per 40 ft GP/high cube container:594 (18 pallets) Panels per 53 ft truck:792 (24 pallets) ELECTRICAL DATA Product Code*: RECxxxAA Pure-RX Power Output - PMAX (Wp) 450 460 470 Watt Class Sorting - (W)0/+10 0/+10 0/+10 Nominal Power Voltage - VMPP (V) 54.3 54.9 55.4 Nominal Power Current - IMPP (A) 8.29 8.38 8.49 Open Circuit Voltage - VOC (V) 65.1 65.3 65.6 Short Circuit Current - ISC (A) 8.81 8.88 8.95 Power Density (W/sq-ft)20.1 20.5 21.0 Panel Efficiency (%) 21.6 22.1 22.6 Power Output - PMAX (Wp)343 350 358 Nominal Power Voltage - VMPP (V) 51.2 51.7 52.2 Nominal Power Current - IMPP (A) 6.70 6.77 6.86 Open Circuit Voltage - VOC (V) 61.3 61.6 61.8 Short Circuit Current - ISC (A) 7.11 7.17 7.23 Values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/m², temperature 77°F (25°C)), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s)). * Where xxx indicates the nominal power class (PMAX) at STC above. GR GR 20.5±0.5 GR GR GR GR GR 0.43±0.010.26±0.010.8±0.02 0.24±0.01 66.9 66.9 68.0 ±0.1 32.2 17.9 46.1 ±0.10.9 23.4 ±0.12 48.1 ±0.10.71.8 1.222.5 594 ±317 45 30Living Building Challenge Compliant MAXIMUM RATINGS Operational temperature:-40 ... +185°F System voltage:1000 V Test load (front):+7000 Pa (146.2 lbs/sq-ft)* Test load (rear):-4000 Pa (83.5 lbs/sq-ft)* Series fuse rating:25 A Reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) TEMPERATURE RATINGS* Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of PMAX:-0.24 %/°K Temperature coefficient of VOC:-0.24 %/°K Temperature coefficient of ISC:0.04 %/°K *The temperature coefficients stated are linear values Irradiance (W/m²)Rel. Efficiency (%)Typical low irradiance performance of module at STC:Ref: PM-DS-AAPRX-Rev- 3.1 10.23Specifications subject to change without notice. PARTS LIST DESCRIPTIONQTYITEM SNAPNRACK, ANCHOR L FOOT, BLACK11 SNAPNRACK, BUTYL, 2.5IN X 4.5IN, 0.200IN THICK12 SNAPNRACK, ULTRA RAIL MOUNT THRU PRC, BLACK13 SNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, BLACK14 5/16IN-18 X 2-1/4IN SS HCS BOLT BLACK15 SNAPNRACK, ULTRA RAIL MOUNT SPRING CAGE16 SNAPNRACK, ULTRA RAIL MOUNT SPRING, SS17 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, TDS, ULTRA RAIL ANCHORFOOT 242-10038 mwatkins THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 225 BUSH STREET, SUITE 1400 ● SAN FRANCISCO, CA 94104 USA PHONE (877) 732-2860 ● CONTACT@SNAPNRACK.COMB REV: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, BUTYL VARIES, REFER TO SNAPNRACK ENGINEERING VARIES, REFER TO SNAPNRACK ENGINEERING 16 FT-LBS UL 2703, FILE E359313; TAS-100(A)-95 WIND-DRIVEN RAIN TEST 0.70 DOC NUMBER: SNR-DC-01314 SUNRUN INSTALLATION SERVICES INC. SHEET: 1:2UNITS: IN, LB, DEG [MM, KG, DEG]11/6/2023 DATE: 4 3 1 6 5 2 7 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, TDS, ULTRA RAIL ANCHORFOOT 242-10038 mwatkins THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 225 BUSH STREET, SUITE 1400 ● SAN FRANCISCO, CA 94104 USA PHONE (877) 732-2860 ● CONTACT@SNAPNRACK.COMB REV: DOC NUMBER: SNR-DC-01314 SUNRUN INSTALLATION SERVICES INC. SHEET: 2:2UNITS: IN, LB, DEG [MM, KG, DEG] DATE: 11/6/2023 2.25 [57.2] 4.50 [114.3] 2.60 [66.0] n.27(X3) n.56(X2) n.33 .63 [15.9] 1.25 [31.8] 2.25 [57.2] 1.30 [33.0] .63 [15.9] 1.60 [40.6] 1.63 [41.3] 4.22 [107.2] 2.50 [63.5] .20 [5.1] 1.882.88 47.8 73.2[] .19 [4.8] .19 [4.8] 1.00 [25.4] SLOT 1.50 [38.1] 3.13 [79.4] DATA SHEET IQ8X Microinverter Our newest IQ8 Series Microinverters are the industry’s first microgrid-forming*, software-defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application- specific integrated circuit (ASIC), which enables the microinverter to operate in grid-tied or off-grid mode. This chip is built using advanced 55-nm technology with high-speed digital logic and superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. IQ8X Microinverter is the latest addition to this family, designed to support PV modules with high output DC voltage and cell counts, such as 80-half-cut cells, 88-half-cut cells and 96-cells. *Meets UL 1741 only when installed with IQ System Controller 2 or 3. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL Listed as PV rapid shutdown equipment and conform with regulations when installed according to the manufacturer’s instructions. Connect PV modules quickly and easily to the IQ8 Series Microinverters with integrated MC4 connectors. Easy to install • Lightweight and compact with plug-and-play connectors • Power line communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produces power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB) NOTE: • IQ8 Series Microinverters cannot be mixed with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, and so on) in the same system. • IQ Microinverters ship with default settings that meet North America’s IEEE 1547 interconnection standard requirements. Region-specific adjustments may be requested by an Authority Having Jurisdiction (AHJ) or utility representative, according to the IEEE 1547 interconnection standard. An IQ Gateway is required to make these changes during installation. IQ8X-MC4-DSH-00185-3.0-EN-US-2024-02-12 © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. (1) No enforced DC/AC ratio. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. (4) IQ8X is not certified for use with Enphase Three Phase Network Protection Relay (NPR-3P-208-NA) and is, therefore, designed for single-phase operation only. Check with the local utility requirements if you wish to install single-phase inverters across three phases. IQ8X Microinverter INPUT DATA (DC)UNIT IQ8X-80-M-US Commonly used module pairings 1 W 320–540 Module compatibility —To meet compatibility, PV modules must be within the following maximum input DC voltage and maximum module Isc Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator MPPT voltage range V 43–60 Operating range V 25–79.5 Minimum and maximum start voltage V 30–79.5 Maximum input DC voltage V 79.5 Maximum continuous operating DC current A 10 Maximum input DC short-circuit current A 16 Maximum module Isc A 13 Overvoltage class DC port —II DC port backfeed current mA 0 PV array configuration —Ungrounded array; no additional DC side protection required; AC side protection requires a maximum of 20 A per branch circuit OUTPUT DATA (AC)UNIT IQ8X-80-M-US @240 VAC IQ8X-80-M-US @208 VAC Peak output power VA 384 366 Maximum continuous output power VA 380 360 Nominal grid voltage (L-L)V 240, split-phase (L-L), 180°208, single-phase (L-L), 120° 4 Minimum and maximum grid voltage 2 V 211–264 183–229 Max. continuous output current A 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 47–68 AC short circuit fault current over three cycles Arms 2.70 Maximum units per 20 A (L-L) branch circuit 3 —10 9 Total harmonic distortion %<5 Overvoltage class AC port —III AC port backfeed current mA 18 Power factor setting —1.0 Grid-tied power factor (adjustable)—0.85 leading … 0.85 lagging Peak efficiency %97.3 97.0 CEC weighted efficiency %96.5 96.5 Nighttime power consumption mW 26 12 MECHANICAL DATA Ambient temperature range -40°C to 65°C (-40°F to 149°F) Relative humidity range 4% to 100% (condensing) DC connector type Stäubli MC4 Dimensions (H × W × D); Weight 212 mm (8.3") × 175 mm (6.9") × 30.2 mm (1.2"); 1.1 kg (2.43 lb) Cooling Natural convection – no fans Approved for wet locations; Pollution degree Yes; PD3 Enclosure Class II double-insulated, corrosion-resistant polymeric enclosure Environmental category; UV exposure rating NEMA Type 6; outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01. This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014, NEC 2017, NEC 2020, and NEC 2023 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer’s instructions. IQ8X-MC4-DSH-00185-3.0-EN-US-2024-02-12 REVISION DATE DESCRIPTION DSH-00185-3.0 February 2024 Updated the information about IEEE 1547 interconnection standard requirements. DSH-00185-2.0 November 2023 Preliminary release - public. DSH-00185-1.0 October 2023 Preliminary release. IQ8X-MC4-DSH-00185-3.0-EN-US-2024-02-12 © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. Revision history snapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience WESTSHORE DESIGN ENGINEERS, P.C. 6279 JOHNSTON RD. ALBANY Ϳ NEW YORK Ϳ 12203 WestShore Design Engineers ۅ 6279 Johnston Rd. ۅ Albany, NY 12203 Subject: Padilla Residence 17329 Joplin Ave. Lakeville, MA To Whom It May Concern, The following references the Padilla Residence in Lakeville, MA: 1. Existing roof framing: Roofs 1,2,3,4: Pre-fabricated/engineered wood truss is 2x4 at 24”o.c. Roof 5: Conventional framing is 2x6 at 24”o.c. with an 8’-4” span. This existing structure is capable to support all the loads indicated below for this photovoltaic project. 2. Roof Loading: - 4psf dead load (modules plus mounting hardware) - 50psf ground snow load - 5.1psf roof materials (1.1psf 2x4, 1.5psf sheathing, 2.5psf asphalt shingles) - Exposure Category B, 129mph wind (3 sec.) This installation design will be in general conformance to the manufacturer’s specifications, and complies with all applicable laws, codes, and ordinances, specifically the International Building Code/IBC 2015 and International Residential Code/IRC 2015 including all MA regulations and amendments. The spacing and fastening of the mounting brackets is to have a maximum of 48”o.c. span between mounting brackets, staggered, and secured using 5/16” diameter corrosive resistant steel lag bolts and a 2.5” minimum embed. Snap N Rack deck attachments or industry similar in lieu of L foot anchors installed per manufacturer specifications and recommendations. Thank you. Westshore Design Engineers 9/12/2024 John Eibert Nicolas Nitti, PE Project Coordinator President To: All Energy Solar 66D Mainline Dr. Westfield, MA Date: September 12, 2024 Ref.: 24090558