Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA226683 - 17005 Draper Way-Permit Pack
RESIDENTIAL BUILDING PERMIT APPLICATION CITY OF LAKEVILLE BUILDING INSPECTIONS DEPARTMENT 20195 HOLYOKE AVENUE LAKEVILLE, MN 55044 952-985-4440 Office Use Only __________________ Permit Number ___________________ Received By ___________________ Date Received ___________________ Fee Total SITE ADDRESS: MAILING ADDRESS: CITY: STATE: ZIP: JOB DESCRIPTION:__________________________________ MASTER PLAN: (Number or Address)____________________ LIST OTHER STRUCTURES ON PROPERTY:_______________________________________________________________ ESTIMATED VALUATION: PROPOSED START DATE: END DATE: (New Residential Only): LEGAL DESCRIPTION: LOT: _____ BLOCK: _____ SUBDIVISION: APPLICANT IS: RESIDENT OWNER CONTRACTOR EMAIL NEW MODEL HOME: YES NO (IF YES – ADMINISTRATIVE PERMIT REQUIRED) PLEASE FILL OUT THE FOLLOWING COMPLETELY (All Contractor information must be as listed on State License) RESIDENT OWNER NAME:_______________________________________________________________________________ HOME PHONE #:_____________________________ CELL PHONE:___________________________ GENERAL CONTRACTOR Homeowner Contractor CONTRACTOR:_______________________________________________________________________ LICENSE #:BC______________ LEAD CERTIFICATE#_______________ (PRE 1978 STRUCTURE) OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ PLUMBING WORK Homeowner Contractor CONTRACTOR:__________________________________________LICENSE #: PM______________ OFFICE PHONE #:_____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ MECHANICAL WORK Homeowner Contractor CONTRACTOR:________________________________________ _______________________________ _____________________________ CELL PHONE:___________________________ ADDRESS:____________________________ CITY:________________ ST:______ ZIP:____________ BOND #:_______________________________________ EXPIRATION DATE____________________ SEWER/WATER CONTRACTOR New Construction Only NAME:________________________________________________ ______________________________ _____________________________ CELL PHONE:______________________________ BOND #:_______________________________________ EXPIRATION DATE____________________ NAME OF APPLICANT (Please Print)DATE I HEREBY APPLY FOR PERMIT AND ACKNOWLEDGE THAT ALL INFORMATION ON THIS APPLICATION IS COMPLETE AND ACCURATE. THIS IS NOT A PERMIT AND WORK IS NOT TO COMMENCE UNTIL SUCH TIME A PERMIT IS ISSUED. ALL WORK WILL COMPLY WITH LAKEVILLE CITY CODE, THE MINNESOTA STATE BUILDING CODE, AND THE APPROVED PLANS. INTEREST EARNINGS ON ESCROW ACCOUNTS, IF ANY, WILL BE RETAINED BY THE CITY TO OFFSET THE ADMINISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. OFFICE PHONE #:_ OFFICE PHONE #:_ *Entering your name affirms your intent to comply with the statement above. * Submit Application To: permits@lakevillemn.gov RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING BUILDING DUPLEX AS BUILT TOWNHOUSE UNITS BUILDING FINAL DETACHED TOWN HOUSE UNIT CONDO REROOF RESIDE RES ADDN/REPAIR/RMDL DECK PORCH GARAGES LOWER LEVEL FINISH ADDITION FOUNDATION ONLY MISCELLANEOUS DEMO APPROVED BY: BUILDING INSPECTOR: Date: PLUMBING/MECHANICAL INSPECTOR: Date: COMMENTS: CITY BUILDING VALUATION: $ BUILDING PERMIT FEES $PERMIT FEE $PLAN CHECK $SURCHARGE $METRO SAC $CITY WATER HOOKUP UNIT $CITY SEWER HOOKUP UNIT $LANDSCAPE ESCROW $TREE ESCROW $MISC ESCROW $PLUMBING $MECHANICAL $SEWER WATER WATER METER PRESSURE REDUCING VALVE $OTHER $TOTAL METER SIZE PRESSURE REDUCING VALVE SEWER/WATER SEWER/WATER FINAL STREET DRAINTILE BUILDING INFORMATION TYPE OF CONSTRUCTION ZONING CODE EDITION FIRE SUPPRESSION SYSTEM OCCUPANCY GROUP MECHANICAL AIR TEST FINAL ROUGH-IN PLUMBING FINAL ROUGH-IN INSULATION LATH DECK FOOTING FIREPLACE FOOTING FOUNDATION FRAMING PORCH FRAMING PORCH FOOTING POURED WALL SITE LOWER LEVEL FINAL OTHER DECK FRAMING LOWER LEVEL FRAMING LANDSCAPING DECK FINAL $ $ ACCESSORY BUILDING EGRESS WINDOW UNDERGROUND ROOF PLAN1/4"=1'-0"6:128:121'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"AAAABBBBCCCC17' RIDGE VENT 1'-8"8:128:128:126:1219' RIDGE VENT4:1210:126:126:128' RIDGE VENTREFSIDING LEGENDALAP SIDING "B"LAP SIDING "A"PRODUCTCBD5" TRIM - VINYL LINEALNOT USEDE6 1/2" VINYL BEAD BDThese plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2020CAT FRONT ONLY1/2"=1'-0"TYPICAL WDW & DOOR TRIM3 1/2" VINYL TRIM 5" VINYL TRIM5" VINYL TRIM3 1/2" VINYL TRIM LIGHT FIXTURES1/2"=1'-0"BLOCKING AT7-1/4"12" 4"4" DIA. HOLE1.0XELDER X304-D-GLPC#1054,1057,1064,1068:11-22-LLPC#1082: 2-23-2023-LLPC#1120: 7-13-2023-LLPERMIT/CONSTRUCT: 8-16-24-RK20860 KENBRIDGE COURT, SUITE 100LAKEVILLE, MN 55044 (952)985-7272CUST:SPEC HOMEX304-DELDERA D.R. HORTON COMPANYTYPICAL PORCH COLUMN:6x6 TREATED POST WITHIN10" SQUARE BOXED COLUMN5/4" x 3" - WOODGRAINOVER5/4" x 10" - WOODGRAINWOODGRAIN PANEL5/4" x 3" - WOODGRAIN5/4" x 10" - WOODGRAIN10" SQUARE COLUMN9 1/2"9 1/2"6x6 POSTBLOCKING2x4 TREATED1/2" OSB4/4" x 3" - WOODGRAINCORNER TRIM(FRONT & REAR)4/4" x 2" - WOODGRAINCORNER TRIM(SIDES)4/4" x 3" - WOODGRAINCORNER TRIM(FRONT & REAR)2"=1'-0"1/4"=1'-0"30°3-CAR GARAGEA6:12 PITCHELDER X304 D1xXXXXX1'-0"1'-0"4:12 PITCHAASTEEL PANEL OVERHEAD DOORADDRESS NUMBERD6:12 PITCH10:12 PITCHFALSE CORNERFALSE CORNER8'-8"4'-0"496 SQ. FT. TOTAL FACING64 SQ. FT. STONE (12.9%)46 SQ. FT. WINDOW (9.3%)9 7/16"6:12 PITCH812812LEFT ELEVATION1/8"=1'-0"REAR ELEVATION1/8"=1'-0"RIGHT ELEVATION1/8"=1'-0"A2x42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BE42" MIN BELOW FINISHED GRADEALL EXTERIOR FTGS TO BEA6:12 PITCHAADB7 7/16"HEEL ASPHALT SHINGLESFLASH OVER ALL EXT OPGS40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R8061'-0"6:12 PITCHAALL EXTERIOR FTGS TO BE42" MIN BELOW FINISHED GRADEDB1241261'-0"7 7/16" HEEL 8:12 PITCH8128:12 PITCH8:12 PITCH1264'-0"8'-0"GRADE = 936.3GRADE = 936.3GRADE = 936.3GRADE = 935.63GRADE = 935.63GRADE = 934.8GRADE = 934.8GRADE = 935.6321'-0"16'-6"4'-0"GRADE = 935.63GRADE = 935.63PERMIT/CONSTRUCT PLANS17005 DRAPER WAYLOT 14 BLOCK 3 - BROOKSHIREConcept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode08/20/2024jnuetzman These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2020C2.0XELDER X304-D-GLPC#1054,1057,1064,1068:11-22-LLPC#1082: 2-23-2023-LLPC#1120: 7-13-2023-LLPERMIT/CONSTRUCT: 8-16-24-RK41'-6"6'-6" 48'-0"29'-0"48'-0" 22'-10"25'-2"20'-6"6'-2 1/2"9'-5 1/2"2'-9 1/2"15'-10"6'-6" 4'-4 3/4"UNEXCAVATED6" CURB (OMIT CURB AT GARAGE DOOR OPENINGS)6" THICK, 3'-6" HIGH16"x8" CONC. FTG.POURED CONC. WALLFOUNDATION PLAN1/4"=1'-0"FULL10'-6 1/2"6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 3'-6" HIGHUNEXCAVATED2'-3 1/2"6'-2 1/2"6" CURB, 2" INT. LEDGE,POURED CONC. WALL18"x8" CONC. FTG.10" THICK, 4'-6" HIGH2" EXT. LEDGE6" CURB, 2" INT. LEDGE,POURED CONC. WALL18"x8" CONC. FTG.10" THICK, 4'-2" HIGH2" GARAGE SLAB LEDGE6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 3'-6" HIGH6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 4'-6" HIGHCONC PAD FTG24x24x8CONC PAD FTG 30x30x12 TREATED BOTTOM PLATE6" WIDE, 3'-6" HIGH CONC WALL16x8 CONC FTGANCHORS AT 6'-0" O.C.2x6 STUDS AT 16" O.C.2x6 BRNG WALL ABOVECONC PAD FTG24x24x8CONC PAD FTG24x24x816"x8" CONC. FTG.MIN. 3'-6" BELOW GRADEPOURED CONC. WALL6" THICK, 3'-6" HIGHF.D.SEWERCLEANOUTFOR KITCHEN ISLAND SLEEVE/CONDUIT39'-0"7'-6"2'-7 1/2"21'-6"2'-7 1/2"16'-3"10'-0"6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 4'-2" HIGH10'-0"20'-10"2'-0"7 1/2"8'-3"1'-1 1/2"CONC PAD FTG36x36x12CONC PAD FTG24x24x8CONC PAD FTG24x24x8#5 BARS @ 12" O.C.10'-0"39'-0"18" STEP INFOOTING8" STEP IN TOPOF FOUNDATION934.8936.3935.6393 5 . 6 3 DROPPED 8"THICKEN SLAB - SEE SECTION A/ALINE OF INSETSTEP ABOVE8'-0"6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 5'-0" HIGH16'-6"21'-0"8" THICK, 5'-0" HIGH4'-0"6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 4'-2" HIGH6" STEP INFOOTING4" STEP INFOOTING936.3935.638" STEP INFOOTING4'-0"6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 4'-2" HIGH8" STEP IN TOPOF FOUNDATIONPERMIT/CONSTRUCT PLANS17005 DRAPER WAYLOT 14 BLOCK 3 - BROOKSHIREPLAN OPTIONSSLAB FOUNDATION3RD GARAGE STALLGARAGE FLOOR DROPPED 8"6" CURB, 2" LEDGEPOURED CONC. WALL16"x8" CONC. FTG.8" THICK, 4'-2" HIGHUFER Ground-Provide 20' Rebar in footing and stubup near electrical service panel. 1ST FLOOR PLAN1/4"=1'-0"These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2020C3.0XELDER X304-D-GLPC#1054,1057,1064,1068:11-22-LLPC#1082: 2-23-2023-LLPC#1120: 7-13-2023-LLPERMIT/CONSTRUCT: 8-16-24-RKUP16R41'-6" 16'-4"25'-2" 13'-10"2'-6"7'-8"17'-6" 5'-10"8" 6'-6"29'-0"5'-0"48'-0"22'-10"25'-2" 48'-0" 6'-6"15'-10" 4'-3"6'-6"9'-2"3'-4"5'-8"4'-4"10'-6"2'-0"1'-2"4'-2"1'-2"12'-6"14" MFD FLOOR TRUSSES INSTALL PER MFRS SPECS LIVINGROOMHD-FLR16x7 OVERHEAD DOOR3050 SH3050 SH3050 SH14" MFD FLOOR TRUSSESINSTALL PER MFRS SPECS 4'-2"DROPPED BEAMDROPPED BEAM2-82'-6"2'-2"6"879 SQ. FT.NOTES:-9'-1 1/8" PLATE HEIGHT TYPICAL-WDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)-TYP. FIRST FLOOR WINDOW HEAD HEIGHT AT 7'-11 3/8" U.N.O.-BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFR2x6 BRNG WALLAHUWH2-8BEDRM #3CPT.BEDRM #4CPT.BEDRM #2CPT.BEDRM #1CPT.W.I.C.CPT.BATH #1HD-FLRLOFTCPT.DN16RW.I.C.CPT.W.I.C.CPT.BATH #2HD-FLRLAU.HD-FLR3050 SH3050 SH29'-0"4'-10"12'-2"2'-6"9'-8"12'-0"2'-6"9'-6"41'-6" 6'-5"17'-3"11'-2" 11'-9"5'-6" 6'-6" 48'-0" 6'-8" 16'-6"14'-4"11'-2" 8'-8"5'-8" 48'-0" 6'-0"3050 SH2W 3050 SH7'-4"3'-10"3050 SHMFD TRUSSES AT 24" O.C.MFD TRUSSES AT 24" O.C.DRYERWASHER2-42-62-62-42-42-82-64-02-62-62-62-42-02x6 WALL2x6 WALLSHOWER34x60 FBGL29'-0"7'-6"5'-2"21'-6"7'-0"14'-6"2'-4"2020 FX7'-0"3'-0"5'-6"6'-6"9'-10"1'-2"11'-6"11'-0"2'-6"8'-2"2'-10"2'-0"6'-2"5'-4"3'-7"6'-4"3'-8"3'-8" 5'-2"2'-4"3'-10"6'-6" 3'-8"6'-0"4'-4"60"60"2ND FLOOR PLAN1/4"=1'-0"NOTES:-8'-1 1/8" PLATE HEIGHT TYPICAL-WDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)-TYP. SECOND FLOOR WINDOW HEAD HEIGHT AT 6'-11 3/8" U.N.O.-BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFR1304 SQ. FT.LIVING AREA3-0 W/TRANSOM22x30ATTICACCESS2W 3050 SH3'-4"3'-4"2020 FX3'-8"3'-9"W/ WOOD CAP42" HIGH ANGLED WALLW/ WOOD CAP42" HIGH HALF WALLW.S.WINDOW & DOOR SCHEDULECALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#3-0 DR W/ TRANSOM0.31ENTRY0.2313050 SHENTRY11KITCHEN3040 SH1LIVING ROOM6068 SGD3050 SHLIVING ROOM20.3136 1/4" X 60 1/4"0.310.3136 1/4" X 48"0.310.3172 1/8" X 80"0.320.310.3138.25" X 95.2536 1/4" X 60 1/4"WINDOW & DOOR SCHEDULE- UPPER LEVELCALL-OUTU-FACTORROUGH OPENINGLOCATIONSHGC#13050 SH1BEDROOM #1BEDRM #2BEDRM #410.310.310.310.310.3136 1/4" X 60 1/4"0.313050 SH36 1/4" X 60 1/4"3050 SH20.3136 1/4" X 60 1/4"0.31BEDRM #32W 3050 SH1LOFT0.310.3172 1/8" X 60 1/4"1WIC0.31BATH #1124" X 24"0.310.322W 3050 SH72 1/8" X 60 1/4"2-614'-0"x8'-0"CONC PATIO5-0 FBGL TUB/SHWR 2'-2"2-82'-10"1'-6"3'-3"SILLCOCKRADON VENT PIPE(BSMT PLAN)RADONVENT PIPE(SLAB PLAN)RADONVENT PIPE(SLAB PLAN)9'-3"12'-9"5'-0"13'-0"3'-0"6068 SGDWSMETERRISERAIREXCHGRSILLCOCK2x6 WALL7'-1"7'-0" CABTS.3'-6" TOP7'-4" TOP4'-4 1/2"KIT.HD-FLR20 AMP.MICRO HOODCIRCUITRANGE2'-4"SINK DW REF.SUBFLOOR TO43 1/2" FROM TOP OFSET KITCHEN WINDOWSRGH.OPG. OF WINDOW4'-11 1/2"3040 SH 2-45'-0"3'-10 1/2"2'-4"2'-2"11'-3"7'-10 1/4" INSIDE FRAMINGNOTE:FRAMER TO ROCK , POLY & INSULATEMECH ROOM EXTERIOR WALLS PRIORTO MECH EQUIPMENT BEING INSTALLED 7'-6"12'-2"ELEC FIREPLACE3/16"=1'-0"6'-0"1'-4"18-1/4"x44-1/2"S/R1'-6 1/4"RGH OPGALLUSION 48 ELEC FP1'-4"1'-6 1/4" 10" 2X6 WALL 2-2X101/2" PLYWD2X6 FRAMINGINSULATION & 1 LAYEROF ROCK BY FRAMERSMANTLE4'-2"1/2" ROCK OVERROCK RETURNSOF FIREPLACE OPG.+-3'-8 1/2"1'-1 3/4"1'-1 3/4"2020 FX1'-0"GIRDER TRUSS1BEDROOM #10.312020 FX24" X 24"0.3224" X 24"0.322020 FX2020 FX7'-5"A/C8'-9" CLEAR FRAMING2'-3"DININGHD-FLRENTRYHD-FLRLFT-RGT DIRECTIONLFT-RGT DIRECTION56 SQ FTMECHF.D.VENT HOODTO OUTSIDETYPICAL PORCH COLUMN:6x6 TREATED POST WITHIN10" SQUARE BOXED COLUMN48 SQ. FT.CONCPORCH16x36 MECHANICAL SOFFITPWDRHD-FLRTOWEL RINGTPH 7'-10"3'-9"2-4PED.2x6 WALL2-4SEWERCLEANOUT4'-6"2'-2"OUTLET INSTALLED20AMP DEDICATEDON SIDE WALL OFFIREPLACE OPGDO NOTADDITIONAL NOTESINTERIOR SWING DOORS: RGH OPG HGT IS 83", THE WIDTH IS THE SIZE OF THE DOOR PLUS 2"INTERIOR BI-FOLD DOORS: RGH OPG HGT IS 82", THE WIDTH IS THE SIZE OF THE DOOR PLUS 1-1/2"NOTE: BUILD AND ROCK A SOFFIT AROUND ALL DROPPEDMECHANICAL DUCTWORKOUTLET &TECH TUBEPANIC PAN20'-10"39'-0"7'-6"10'-9"2'-10"4'-8"21'-6"10'-9"GARAGESLOPE TO DOORS4" CONC FLOOR638 SQ. FT. (INSIDE)TYPICAL 2x6 GARAGE WALLS6"2'-0"10'-0"4'-9"5'-3"8x7 OVERHEAD DOORFLUSH BEAMMFD TRUSSES AT 24" O.C.8"4'-6"3'-6"22x30ATTICACCESS10'-0"39'-0"DROPPED 8"1'-0"2'-0"DROPPED BEAMINSET STEP16" WIDEDROPPED SOFFITTHICKEN SLAB - SEE SECTION A/AELEC. FP 6'-0"5 1/2"5'-0"IRRIGATIONSYSTEMPERMIT/CONSTRUCT PLANS17005 DRAPER WAYLOT 14 BLOCK 3 - BROOKSHIREPLAN OPTIONSLIVING ROOM HD-FLRELECTRIC FIREPLACEIRRIGATION SYSTEM3RD GARAGE STALLGARAGE FLOOR DROPPED 8"3.533-Min. 15" clearance to anyobstruction from center ofW.C., 24" in front(typ).BWPsAboveBWPsAbove33.55PFHPFH5669.58553-1/2 x 7-1/4 LSL3-1/2 x 9-1/2 LSL(3)11-7/8 LSL(2)7-1/4 LSL(2) 16" LVL(3) 18" LVL3-1/2 x 9-1/2 LSLVerify loads with girdertruss specs, may requireremoval of top plates atbearing due to crushing.(2)2x8 BEDRM #3BEDRM #4BEDRM #2BEDRM #1W.I.C.BATH #1W.I.C.BATH #2LAU.1/4"=1'-0"ELECTRICAL PLAN2ND FLOORS S S SLSSFANGFI SLSD SDSDSD/CMDSDS SS GFI GFI SLFANSS22x30ATTICACCESS1/4"=1'-0"These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2020C4.0XGARAGEAHUWHELECTRICAL PLAN1ST FLOORS LSS S SSGFIFANS S SSSD TCHIMESHCPWP15 AMP CIRCUITFOR POWER VENTW/ SINGLE RECEPTACLEGFICONC.PORCHLLLLSD/CMDLLLLLSLLLLLLOFTSSS LLLW.I.C.SLIVINGROOMKIT.DININGOPTMETERRISERAIR EXCHGRLLLLLLLLS WPUSBWS4'-6"5'-6"4'-6"LSLSSDISP.DWL LGFISSLPWDR OUTLET FORFUT. WATER SOFT.WPA/CCDROUGH-INBLANK PLATESELDER X304-D-GLPC#1054,1057,1064,1068:11-22-LLPC#1082: 2-23-2023-LLPC#1120: 7-13-2023-LLPERMIT/CONSTRUCT: 8-16-24-RKLVENT HOODTO OUTSIDEOUTLET INSTALLED20AMP DEDICATEDON SIDE WALL OFFIREPLACE OPGABOVE FP MANTLEINSTALL OUTLETCTUBETECHRGH-IN INSIDECABINET ONLYAPPLIANCES TO BEON A GFCI OUTLETNOTE: ALL KITCHENSMART HOMERECEPTACLESYSTEM RECEPTACLELOW VOLTAGESPRINKLERSYSTEMRECEPTACLEGFIDROPPED 8"IRRIGATIONSYSTEMPERMIT/CONSTRUCT PLANS17005 DRAPER WAYLOT 14 BLOCK 3 - BROOKSHIREPLAN OPTIONSLIVING ROOM HD-FLRELECTRIC FIREPLACEIRRIGATION SYSTEM3RD GARAGE STALLGARAGE FLOOR DROPPED 8" These plans, and the concept thereofor used without written consent. And may not be reproducedare the exclusive property of D.R. Horton Inc.,COPYRIGHT D.R. HORTON, INC. 2020C5.0XELDER X304-D-GLPC#1054,1057,1064,1068:11-22-LLPC#1082: 2-23-2023-LLPC#1120: 7-13-2023-LLPERMIT/CONSTRUCT: 8-16-24-RK1/2" SHEATHINGMIN. R-20 INSULATION2x6 STUDS AT 16" O.C.HOUSE WRAPSIDING PER ELEV.BARRIER PASTACOUSTICAL SEALANTEXTEND POLY VAPOR1-1/2" THERMAX2-1/4"X12" DUCTINSULATION(R-10 x 2)1/2"=1'-0"WALL DETAIL4" CONC. GAR. FLOOR5/8" GYP. BD.9'-1 1/8"VARIESSEE PLANVARIES122x6 STUDS AT 16" O.C.BLOCK AT MIDPOINT2x6 BEARING WALL14x8 CONC. FTG.6" HALF HIGH CONC. CURB. BLK.1/2" ANCHOR BOLTSOMIT BEARING WALLAT STEEL OR LVL BEAMR-49 INSUL.MFD TRUSSESAIR CHU TE S APPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGSNOTEDUNLESSOTHERWISENOTEDUNLESSOTHERWISEOVER 1/2" SHEATHINGSHINGLES OVER FELT PAPERRIGID WIND WASH INSTALLED EXTENDINGBARRIER MUST BETO WITHIN 1-1/2" to 2"FROM BOTTOM OFROOF SHEATHING4 MIL. POLY VAPOR / AIR BARRIERALUMINUMCORNICEVENTS40% TO 50% NEAR RIDGEVENT 1/300th OF ROOF AREAREMAINDER IN SOFFITPER IRC SECTION R806TREATED SILL PLATEAPPROVED ANCHORPER CODE (IRC R403.1.6)TREATEDSILL PLATEW/ FOAM SILL SEALMIN. 42" BELOW FINISHED GRADEALL EXTERIOR FOOTINGS TO BE4" INCH CLEAN AGGREGATE ORCONCRETE SLAB AND PREPARED SUBGRADE6 MIL POLY V.B. W/ LAPPED SEAMS 12" BETWEENAPPROVED GAS-PERMEABLE LAYERPASSIVE SUB-SLAB DEPRESSURIZATIONSYSTEM REQUIRED PER MINNESOTARESIDENTIAL ENERGY CODE 1322.2100POURED CONC. WALL(6" CURB, 2" INT. LEDGE)8" THICK, 42" HIGHOPENINGS, JOINTS AND SUMPSFOUNDATION WALL & SLABSEAL JOINT BETWEEN3-1/2" CONC. FLOOR SEALED AT8'-1 1/8"1/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.TRUSSESS PER PLAN3/4" SUBFLOORSEE PLANVERTICAL CLEARANCE OF NOT LESS THANTHE EXTERIOR WALL TOP PLATETO THE ROOF SHEATHINGSIX INCHES FROM THE OUTSIDE EDGE OF6" MIN. HEEL 6'-0" OF ICE & WATER SHIELDINSTALL PER MFR'S SPECSTERMINATE 12" ABOVE ROOF2x6 SUBFASCIAPROVIDE RECEPTACLE FOR FUTURE RADON FANVENT PIPE SHALL BE INSTALLED WITH A MINIMUM24" HORIZONTAL CLEARANCE AND 36" VERTICALCLEARANCE TO ALLOW FOR FUTURE INSTALLATIONOF RADON FAN (ACTIVE SYSTEM)GYP. BD. W/ VAPOR BARR.1/2" SAG-RESISTANTAPPLIED ON WARM-IN-WINTER SIDE OFTHERMAL INSULATION AT ABOVE GRADEFRAMED WALLS, RIM JOISTS, FLRS AND CLGS4 MIL. POLY VAPOR / AIR BARRIERW/ APPROVED SEALANTGYP. BD. W/ VAPOR BARR.1/2" SAG-RESISTANT1/2" GYP. BD.SEAL BEHIND POLY.SEAL BEHIND POLY.1/2" GYP. BD.SEAL BEHIND POLY.PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"PASSIVE RADON VENTLABEL ON EACH FLR"RADON REDUCTION SYSTEM"CONNECTRED TO EACH SIDE OF10' SECTION OF PERFORATED PIPE2x6 EXTERIOR WALLR-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.171/2" EXT. SHEATHING5-1/2" BATT INSULATION2x6 STUDS AT 16" O.C. W/HOUSE WRAPSIDING PER ELEV.R-0.62R-21R-N/AR-N/AINSIDE AIR FILMR-0.681/2" GYP BD.R-0.45OUTSIDE AIR FILMR-0.172x6 EXTERIOR WALL3.5" MIN. POLYURETHANE FOAMAT PERIMETER R=20RUNNING THRU UNCONDITIONEDSPACES TO HAVER-4 INSUL. (MIN)VENT PIPER-10 RIGID INSULATIONINTENDED FOR EXTERIOR USEASTM C578, C612 or C1029INSTALLED PER MFR'S SPECSALL NON-BEARING PARTITION WALLSTO BE FRAMED AT 16" ON CENTER16x8 CONC. FTG.5000 PSI TESTED -OR-APPROVED ADMIXTUREVERTICAL REINFORCINGAS SOIL COND. REQUIRE(SEE HANSON ENGINEERING)"T" FITTING IN AGGREGATE1/2"=1'-0"GARAGE SLAB LEDGE DETAIL4" 8"TYPICAL WALL SECTION1/2"=1'-0"SLAB-ON-GRADE1/4"=1'-0"CROSS SECTION A-A9'-1 1/8" 5'-0"3 1/2" CONC. FLOOR8'-1 1/8" 10'-3 7/8"LIVINGROOMFOYERCONC.PORCHDROPPED HDR5'-10"41'-6"3/4" SUBFLOOR14" MFD FLOOR TRUSSESSLAB-ON-GRADEOWNERSBATHBEDRM #4LOFTW.I.C.16" WIDEDROPPED SOFFITDROPPED BEAM6'-6"8"5'-10"9'-1 1/8" 4'-6" 8'-1 1/8" 10'-3 7/8"29'-0"BEDRM #24'-2"3/4" SUBFLOOR3 1/2" CONC. FLOORMECH.6'-8" MIN HEADROOM HAND RAIL ALL STAIRSPROVIDE MIN. 6'-8" HEADROOM3) LSL STRINGERS7 3/4" MAX RISE10" TREAD CUTSTAIR DATA1/4"=1'-0"CROSS SECTION C-CSLAB-ON-GRADE14" MFD FLOOR TRUSSESMFD TRUSS1241'-8"8 1/8"MFD TRUSS1'-0"1267 7/16"1'-0"7 7/16"1269'-1 1/8"22'-4"25'-8"1/4"=1'-0"CROSS SECTION B-B4" CONC. FLOOR3'-6"3 1/2" CONC. FLOORKITCHEN8'-1 1/8" 10'-3 7/8"BEDRM #348'-0"3/4" SUBFLOOR14" MFD FLOOR TRUSSESSLAB-ON-GRADEGARAGEOWNERSBEDRMDININGBEDRM #2BATH#2DROPPED HDR1'-0"7 7/16"126GIRDER TRUSS6'-6"41'-6"2'-0"1/2"=1'-0"OVER UNCONDITIONED SPACEFLOOR DETAILMFD TRUSS1'-0"9 7/16"812128MECHSOFFITLIVABLE SPACEGARAGER-30 BLOWN-IN INSULATION3/4" SUBFLOOR6" ROUND DUCTWORKFLOOR TRUSSESR-8 INSULATION WRAP5/8" TYPE 'X' GYP. BD.14"SPRAY FOAM INSUL.AROUND DUCTWORKCLOSED CELL1" CLOSED CELLSPRAY FOAM16" MAX SPAN FORVINYL SOFFIT PANELS.FRAMERS TO ADD NAILINGSTRIPS AS NEEDED. R703.3.1.2DROPPED 8"4'-2"8"3'-6"THICKEN SLAB 8"4'-2"PERMIT/CONSTRUCT PLANS17005 DRAPER WAYLOT 14 BLOCK 3 - BROOKSHIRE FOUNDATION DETAILAT FOOTING STEP LOCATIONS1FG1DescriptionDateRevisionProject Number:Date:FG11Sheets: of2Print Name:Signed: License Number:Nick Hanson46665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.January 1, 20244.0011-1-242024 FOUNDATION GUIDEWALL SECTIONWALKOUT WALL CONDITION2FG1WALL SECTIONLOOKOUT WALL CONDITION3FG1WALL SECTIONEXTERIOR UNBALANCED FILLCONDITION4FG1WALL SECTIONFULL HEIGHT WALL CONDITION5FG1REBAR TABLE6FG1SITE ADDRESS:City:State:Zip:MNCOPYRIGHT HANSON GROUP LLC 2024©DRAWING USE GUIDELINES AND LIMITATIONSTHE CONTRACTOR LISTED IN THE TITLE BLOCK BELOW IS LICENSED BY THE HANSON GROUP TO USE THISPACKET WITHIN THESE LIMITATIONS NOTED FOR PROJECTS WHICH THE LICENSEE IS DIRECTLY RESPONSIBLE.THE LICENSEE MAY RELEASE THIS PACKET TO ITS SUB-CONTRACTORS AND CLIENTS FOR USE IN THEPROCUREMENT OF BUILDING PERMITS FOR PROJECTS WHICH THE LICENSEE IS USING THESE DRAWINGS.THE FOUNDATION GUIDELINES ARE TO BE ISSUED TO THE APPROPRIATE BUILDING DEPARTMENT INACCORDANCE WITH THEIR APPROVED PROCEDURE FOR USE BY THE BUILDING AGENCY DURING PLAN REVIEWAND INSPECTIONS.LIMITATIONS1.BASEMENT FOUNDATION WALLS TEN FOOT OR LESS IN CLEAR HEIGHT (FROM TOP OF FLOOR SLAB TO TOPOF CONCRETE WALL AT SILL PLATE BEARING-NOT NECESSARILY BASEMENT CEILING HEIGHT).2.STRUCTURE HEIGHT IS NOT TO EXCEED TWO STORIES ABOVE THE BASEMENT.3.OVERALL BUILDING IS ASSUMED TO FALL WITHIN THE PRESCRIPTIVE LIMITATIONS OF THE CODE. A SITESPECIFIC PLAN REVIEW HAS NOT BEEN PERFORMED.4.STRUCTURES CONSTRUCTED OF WOOD FLOOR, WOOD ROOF, AND WOOD WALLS ONLY. NO PRECAST ORSTRUCTURAL CONCRETE BEARING ON FOUNDATION WALLS IS PERMITTED.5.EXTERIOR GRADE SLOPING DOWN AND AWAY FROM THE FOUNDATION WALLS.6.ANY CASE BEYOND THE ABOVE NOTED ITEMS REQUIRES SEPARATE AND SPECIFIC STRUCTURALENGINEERING DOCUMENTS.COLD WEATHER GUIDELINES:1.THE CONTRACTOR AND CONCRETE SUPPLIER ARE TO WORK TO OBTAIN A MIX DESIGN WHICH WILLADEQUATELY PERFORM UNDER THE EXPECTED CONSTRUCTION CONDITIONS. THE USE OF ADDITIONALCEMENT, HIGH-EARLY STRENGTH CONCRETE, AND/OR ACCELERATOR IS RECOMMENDED ATTEMPERATURES AND CONDITIONS EXPECTED LESS THAN TWENTY DEGREES F.2.DELIVER CONCRETE WARM AND IN A TIMELY MANNER. PLACE CONCRETE EARLY IN THE DAY WHENPOSSIBLE.3.DO NOT ADD ADDITIONAL WATER TO THE CONCRETE. THE USE OF WATER REDUCING AGENTS ISRECOMMENDED WHEN WORKABILITY CONCERNS EXIST. NO CONCRETE IS TO BE PLACED ON SNOW OR INCONTACT WITH FROZEN MATERIALS.4.REBAR DOES NOT NEED TO BE PRE-HEATED, BUT IS TO BE FREE OF FROST, SNOW, AND ICE.5.BLANKETS OR OTHER ACCEPTED PROTECTION IS HIGHLY RECOMMENDED FOR THE TOP 24" OF THE WALLSWHEN THE AIR TEMPERATURE IS LESS THAN TEN DEGREES F AND FOR THE FULL HEIGHT OF THE WALLWHEN THE AIR TEMPERATURE IS LESS THAN ZERO DEGREES F.**THE ABOVE COLD WEATHER GUIDELINES ARE GENERAL RECOMMENDATIONS AND ALL ACI COLD WEATHERREQUIREMENTS ARE TO BE FOLLOWED AT THE RESPONSIBILITY OF THE LICENSEE.MATERIALSCONCRETE WALLS:F'c = 3000 PSI @ 28 DAYSMIX DESIGN AND PROPORTIONED BY CONCRETE SUPPLIERCONCRETE FOOTINGS:F'c = 5000 PSI @ 28 DAYS (OR 3000 PSI WITH AN APPROVED ADMIXTURE THAT PROVIDESA WATER AND VAPOR RESISTANCE AT LEAST OR EQUIVALENT TO 5000 PSI CONCRETE.AGGREGATE: FOOTINGS - 1 12" MAX. WALLS/SLABS - 34" MAX.REINFORCING STEEL: #4- BARS - ASTM A615 GRADE 40#5+ BARS - ASTM A615 GRADE 60TREATED SILL PLATE:SYP GRADE #2 OR BETTERALLOWABLE SOILBEARING PRESSURE1,500 PSF MINIMUMGENERAL NOTES1.DO NOT BACKFILL BASEMENT WALLS UNTIL THE CONCRETE HAS REACHED A MINIMUM COMPRESSIVESTRENGTH OF 2,250 PSI. IN ADDITION, DO NOT BACKFILL UNTIL THE BASEMENT WALLS ARE LATERALLYSUPPORTED BY THE FINAL INSTALLED FLOOR CONSTRUCTION AT THE TOP AND BOTTOM, UNLESSADEQUATE SHORING IS INSTALLED AS REQUIRED. SHORING IS THE SOLE RESPONSIBILITY OF THE GENERALCONTRACTOR.2.STRIP FOOTING MAY BE PLACED AT ELEVATIONS LOWER THAN SHOWN IN THE DETAILS.3.112" DEEP BY 312" WIDE BY CONTINUOUS KEYWAYS MAY BE USED IN LIEU OF DOWELS FOR FULL HEIGHT ANDFROST WALLS.4.STRIP FOOTING TO WALL CENTERLINES MAY BE OFFSET UP TO 2", HOWEVER, A MINIMUM OF 2" OF STRIPFOOTING IS TO EXTEND BEYOND THE WALL FACE ON EACH SIDE.5.PROVIDE CODE REQUIRED FROST PROTECTION TO THE BOTTOM OF ALL FOOTINGS.6.SLOPE GRADE DOWN AND AWAY FROM THE STRUCTURE A MINIMUM OF 6" WITHIN THE FIRST TEN FEETUNLESS ADEQUATE DRAINAGE OR SWALES ARE PROVIDED.7.BOTH MATERIALS AND INSTALLATION OF DRAIN TILE, WATER-PROOFING, CONTROL JOINTS, FLASHING, ANDINSULATION ARE TO BE IN ACCORDANCE WITH THE CODE BY THE GENERAL CONTRACTOR, UNLESS NOTEDOTHERWISE.8.ALL WALL WIDTHS SHOWN ARE NOMINAL DIMENSIONS, UNLESS NOTED OTHERWISE. OVERALL WALLTHICKNESS MAY VARY BY UP TO 12" FROM THAT SHOWN ON THE DRAWINGS.9.REINFORCING PLACEMENT TOLERANCE IS NOT TO EXCEED 12". BARS BEING SPLICED ARE TO BE WITHIN 2"OF CENTERLINE. MINIMUM SPLICE LENGTHS ARE 30 BAR DIAMETERS FOR GRADE 40 STEEL AND 48 BARDIAMETERS FOR GRADE 60 STEEL. TYING IS NOT REQUIRED PROVIDED THESE TOLERANCES ARE MET.10.PROVIDE MATCHING HOOK BARS FOR ALL HORIZONTAL BARS AT WALL CORNERS AND INTERSECTIONS.HORIZONTAL BARS MAY BE PLACED ANYWHERE WITHIN THE WALL AS LONG AS A 2" MINIMUM CLEAR COVERIS ACHIEVED ON ALL SIDES.11.REINFORCING MAY BE BUNDLED UP TO A MAXIMUM OF THREE BARS.12.DOWELS MAY BE DRILLED AND GROUTED IN PLACE. VERTICAL BARS AND DOWELS DO NOT NEED TO ALIGN.VERTICAL BARS MAY BE DRILLED AND EMBEDDED 5" INTO THE STRIP FOOTING IN LIEU OF DOWELS.13.THE BOND BETWEEN CONCRETE AND REINFORCING WILL NOT BE APPRECIABLY REDUCED IF VERY MINORFORM OIL IS PRESENT FOR THE CONDITIONS CONTAINED WITHIN THESE DRAWINGS.14.SILL PLATES ARE TO BE ANCHORED WITH A MINIMUM OF TWO ANCHORS PER SILL SECTION. ALL SECTIONSARE TO HAVE AN ANCHOR WITHIN 4" TO 12" OF EACH END. AN ANCHOR IS TO BE PLACED AT ALL WALLCORNERS AND INTERSECTIONS ON WALLS MORE THAN TWO FEET IN LENGTH. WALLS TWO FEET OR LESS INLENGTH REQUIRE A MINIMUM OF ONE ANCHOR. REQUIREMENTS FOR SHEAR WALLS AND BRACED PANELSMAY BE IN EXCESS OF THESE REQUIREMENTS. TWO INCH WASHERS ARE ONLY REQUIRED AT FULL HEIGHTFOUNDATION WALLS. BUILDING DESIGNER IS TO ACCOMMODATE LOAD PATH FOR ANY VERTICAL LOADTRANSFER OVER A SILL PLATE OVERHANG CONDITION.15.ANCHOR BOLTS 12" DIAMETER OR LARGER ARE NOT REQUIRED TO BE CORROSION PROTECTED INACCORDANCE WITH CODE SECTION R317.3.1 EXCEPTION 1.16.ALL PRE-MANUFACTURED FASTENERS AND CONNECTORS ARE TO BE INSTALLED IN ACCORDANCE WITHTHE MANUFACTURER'S REQUIREMENTS.17.FLOOR BLOCKING IS ONLY REQUIRED AT FULL HEIGHT FIRST FLOOR NON-BEARING FOUNDATION WALLS.18.CARE IS TO BE TAKEN DURING CONCRETE PLACEMENT TO MINIMIZE INADEQUATE HORIZONTAL ANDDIAGONAL COLD JOINTS, AND TO PREVENT THESE JOINTS ENTIRELY IN WALLS WITHOUT VERTICALREINFORCEMENT. ADEQUATELY VIBRATE CONCRETE AT POTENTIAL JOINT LOCATIONS AS REQUIRED,BASED ON PLACEMENT CONDITIONS TO ELIMINATE HONEYCOMBING AND TO ENSURE SUFFICIENT BONDINGIS ACHIEVED.19.TOP AND BOTTOM OF FOUNDATION WALLS ARE TO BE LATERALLY SUPPORTED PRIOR TO BACKFILLING.MEANS AND METHODS OF LATERAL SUPPORT ARE BY OTHERS.20.THESE DRAWINGS ARE INTENDED TO BE A LIMITED COMPONENT DESIGN TO RESIST LATERAL SOILPRESSURES FOR SINGLE FAMILY RESIDENCES. VERTICAL LOADS AND FOOTING DESIGNS ARE TO BE THERESPONSIBILITY OF THE BUILDING DESIGNER. NO SUPPLEMENTAL ENGINEERING OR COMPONENT DESIGNFOR THE FOUNDATION SYSTEM SHALL BE INCLUDED WITH THIS PACKET WITHOUT THE PRIOR REVIEW ANDCONSENT OF THE HANSON GROUP.EQUIVALENT REBAR TABLEFOR BUNDLED HORIZONTAL BARS(2)#4 = (1)#6(3)#4 = (2)#5(3)#5 = (2)#6GRADE 60 #6 VERTICAL BAR SPACING FOR FULL HEIGHT WALLS w/ F'c = 3000 PSIALTERNATIVE TO CODE TABLE R404.1.2EQUIVALENT VERTICAL REBARSUBSTITUTION TABLEBACKFILL TYPECLEAR HEIGHT(SEE 5/FG1)BACKFILL HEIGHT(SEE 5/FG1)7'-6"7'-0" OR LESS8'-6"8'-0"7'-0"6'-0" OR LESS9'-6"9'-0"8'-0"7'-0"6'-0" OR LESS8"10"12"8"10"12"8"10"12"NONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONENONE* = NONE IF F'c = 4,000 PSI*36"*36"*36"*36"*36"*36"36"36"36"36"36"36"36"36"24"24"24"24"SAND (30 PSF/FT)WALL THICKNESSSANDY CLAY (45 PSF/FT)WALL THICKNESSCLAY (60 PSF/FT)WALL THICKNESS#6 @ 24" = #5 @ 18" = #4 @ 12" (GRADE 60) = #4 @ 8" (GRADE 40)(1)#6 = (2)#4 (GRADE 60)#6 @ 36" = #5 @ 24" = #4 @ 18" (GRADE 60) = #4 @ 12" (GRADE 40)(2) #4 HORIZONTAL BARSBOTH TOP & BOTTOMEXTENDED AT LEAST 24"BEYOND EACH END OF STEPSTABLE BANKHIGH FOOTING MAY BEEXTENDED PROVIDEDBARS ARE PLACED ASSHOWNHORIZ. BARSTOP & BOTTOM6" MIN THICK CONCRETEFOUNDATION, SEE OTHERDETAILS FOR MORE INFOOPTIONAL CONTROL JOINTAT EACH END OF STEP72" MAX SPANEQ.EQ.24" MINDETAIL B3" MIN TYPCONCRETE STRIPFOOTING11BDETAIL A36" MINSTEP2 x STEPSTEP NOTE:DO NOT LOCATE CONCENTRATED LOADS IN EXCESS OF 2,000 PLF OR 10,000 POUNDS ABOVE STEPLOCATIONS SHOWNREAR FROST WALLLOOKOUTWALLFULL HEIGHTWALLGARAGE FROSTWALLELEVATIONSHOWN FORREPRESENTATIONPURPOSES ONLY-MAY NOT APPLYELEVATIONSTEP SPACING REQUIREMENTSATYP.6"MIN.WOOD FRAMING ABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAYFROM FOUNDATIONOPTIONAL STEM WALLMINIMUM THICKNESS TOMATCH SILL PLATESILL PLATE TO MATCHFRAME WALL ABOVE16" MAX FOR 4" THICK STEM24" MAX. FOR 6" THICK STEMSLAB-ON-GRADE BY OTHERS(1) #4 x CONTINUOUSHORIZONTAL BAR ATTOP OF WALL6" MIN. C.I.P. CONCRETEFOUNDATION WALLUNREINFORCED CONCRETESTRIP FOOTING SEE 5/FG1#4x2'-0" DOWELS @ 72" O.C. MAX(5" MIN. EMBED) DOWELS ARENOT REQUIRED IF BACKFILL ISPLACED EQUALLY ON BOTHSIDES IN LIFTS NOT TO EXCEED24"-ALTERNATE EACH SIDE6"MIN.3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB#4 x 2'-0" DOWELS (5" MIN.EMBED) CENTERED IN WALL @48" O.C. (SAND SOIL)OR 36" O.C. (SANDY-CLAY SOIL)OR 24" O.C. (CLAY SOIL)DOWELS MUST BE WET SET ORDRILLED AND EPOXY GROUTED6" MIN. THICK C.I.P.CONCRETEFOUNDATION WALLSLOPE GRADE AWAYFROM FOUNDATION12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORS(1) #4 x CONTHORIZONTAL BARAT TOP OF WALLFRAMING & SILLPLATE BY OTHERSSLAB-ON-GRADEBY OTHERSUNREINFORCED CONCRETESTRIP FOOTING SEE 5/FG1(18" MIN WIDTH FOR CLAYBACKFILL OR 16" MIN WIDTH IF2'-6" MAX UNBALANCED BACKFILL)SCOPE OF DRAWINGS:THESE CAST-IN-PLACE CONCRETE FOUNDATION WALL GUIDELINE DRAWINGS ARE PREPARED ANDCERTIFIED BY THE HANSON GROUP IN COMPLIANCE WITH THE MINNESOTA RESIDENTIAL CODE. THESEDRAWINGS CONTAIN STRUCTURAL INFORMATION FOR USE IN THE CONSTRUCTION OF STANDARD C.I.P.CONCRETE FOUNDATIONS FOR TYPICAL RESIDENTIAL CONDITIONS. THIS INFORMATION IS RELEVANTTO THE CONCRETE CONTRACTOR, THE GENERAL CONTRACTOR, AND THE FRAMING CONTRACTOR.THESE DRAWINGS EXPIRE ON DECEMBER 31, 2024.6"MIN. CLEAR HEIGHT BACKFILL HEIGHT112" CLEARUNREINFORCED CONCRETESTRIP FOOTING PER CODEOR BY BUILDING DESIGNER,AS AN ALTERNATIVE GUIDEUSE TABLE SHOWN BELOW8" MIN. C.I.P. CONCRETEFOUNDATION WALL-SEEREBAR TABLE 6/FG1 FORVERTICAL REBARANCHOR BOLTS SEE WALLANCHOR INFO ON 2/FG2FLOOR TO SILLCONNECTION SEE 1/FG2WOOD FLOORSYSTEM BY OTHERSSLOPE GRADE AWAYFROM FOUNDATION2x6 MIN SILL PLATECLEAR HEIGHT OF 8'-0" OR LESS(2)#4xCONT. HORIZONTAL BARSCLEAR HEIGHT OF 8'-0" OR MORE(3)#4xCONT. HORIZONTAL BARSCONCRETESLAB-ON-GRADEPLACED TIGHT TOFOUNDATION WALL#4x2'-0" DOWELS @ 72" O.C.MAX (5" MIN. EMBED)GENERAL STRIP FOOTING SIZE GUIDESOILONE-STORY STRUCTURETWO-STORY STRUCTURE2000 PSF16" WIDE x 8" THICK20" WIDE x 8" THICK1500 PSF20" WIDE x 8" THICK26" WIDE x 8" THICKTHIS TABLE IS A GENERAL FOOTING SIZE GUIDE FOR TRIBUTARY UNIFORM LOADING ONLY BASED ONMAXIMUM 25'-0" FLOOR SPANS & 50'-0" ROOF SPANS AND IS TO BE VERIFIED BY HOME DESIGNER. FURTHERCONSIDERATION IS TO BE TAKEN BY HOME DESIGNER FOR VENEER WEIGHT, WALL THICKNESSES OVER 10",AND FLOOR AND ROOF DEAD LOADS OVER 15 PSF. CONCENTRATED LOADS FROM GIRDER TRUSSES, BEAMS,HEADERS, ETC. ARE TO BE ACCOUNTED FOR AND SIZED INDEPENDENTLY OF THIS GUIDE BY OTHERS.6'-0" MAX WOOD FRAMINGABOVE BY OTHERS12"Ø x 10" LONG ANCHORBOLTS (7" MIN. EMBED)@ 72" O.C. MAX. OREQUIVALENT METALSTRAP ANCHORSSLOPE GRADE AWAY FROMFOUNDATION AT A GRADUAL 2%SLOPE PER GENERAL NOTE 6SILL PLATE TO MATCHFRAME WALL ABOVE#4 x CONTINUOUS HORIZONTALBARS @ 24" O.C. TYP.OPTIONAL 2" RIGID INSULATION ONINSIDE FACE AND UNDERSLAB-ON-GRADE FOR 24" MIN.UNREINFORCED CONCRETESTRIP FOOTING SEE 5/FG1(DROP FOR FROST ASREQUIRED PER SITE DESIGN)#4x2'-0" DOWELS @ 48" O.C.MAX (5" MIN. EMBED)(1) #4 x CONTINUOUS HORIZONTALBAR AT TOP OF WALLOPTIONAL SLAB LEDGECONCRETE SLAB-ON-GRADE8" MIN. C.I.P. CONCRETEFOUNDATION WALL#4 x 5'-0" HOOKS @ 24" O.C.EMBEDDED IN FOUNDATIONWALL & CAST INTO SLAB(MAY REDUCE 2'-0" LEG LENGTH& DRILL IN & EPOXY 8" MIN.INTO FOUNDATION WALL)3'-0"NO HOOKS @ 3'-0" OR LESS GRANULAR MATERIAL (SAND)DETAIL ABOVE MAY ONLY BE UTILIZED FOR A LENGTH OF 15'-0"#5 VERTICAL BARS @ 24" O.C.CENTERED IN WALL TO AID INTHE REDUCTION OF CRACKINGAND BACKFILLING ISSUES PRIORTO TOP OF WALL PINNINGCONTRACTOR IS TO PROVIDETEMPORARY TOP OF WALLBRACING UNTIL GARAGESLAB-ON-GRADE IS IN PLACE(HOOKS INTO GARAGE SLABPROVIDE REQUIRED TOP OFWALL LATERAL SUPPORT)2'-0"8'-0" OR LESS9'-0" MAX.10'-0" MAX.5851 Cedar Lake RoadSuite 202St. Louis Park, MN 55416Tel 612-708-3572www.hansongroupmn.comD R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 COPYRIGHT HANSON GROUP LLC 2024©DescriptionDateRevisionJanuary 1, 2024Project Number:Date:4.001FG22Sheets: of2Print Name:Signed: License Number:Nick Hanson1-1-2446665Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.CONNECTION INFOTOP OF WALL CONNECTION TOFLOOR SYSTEM1FG2BRICK LEDGE INFO5FG2WALL SECTIONAT WINDOW WELL LOCATIONS6FG2STOOP INFO7FG2WALL ANCHOR INFOANCHOR BOLT AND ALTERNATIVESPACING2FG2BLOCKING DETAILFLOOR JOIST CONDITION3FG2BLOCKING DETAILFLOOR TRUSS CONDITION4FG2SITE ADDRESS:City:State:Zip:MNVENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATIONWALL SEE5/FG1WOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS16" HIGH MAX x6" THICK MINSTEM6"MINWOOD FLOORSYSTEM BYOTHERSFRAMING BY OTHERS6" MIN THICK STEM#4 DOWELS @ 36" O.C.EMBEDDED 24" INTOLOWER WALLFOUNDATIONWALL SEE5/FG1VENEER ORSLAB-ON-GRADEBY OTHERS12"VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 2/FG1 OR 3/FG1FRAMING BYOTHERS16" HIGH MAXx 4" THICK MINSTEMTHICKNESS TOMATCH SILLPLATE6"3'-0" MAX VENEER ORSLAB-ON-GRADEBY OTHERSFOUNDATION WALLSEE 4/FG1SLAB-ON-GRADEFRAMING BYOTHERS6" MIN THICKSTEMDETAIL @ HIGH GRADESIM @ NON-BEARINGDETAIL @ LOOKOUTSIM @ FROST WALLDETAIL @ FROST WALLSw/ LOW GRADEDETAIL @ LOW GRADESIM @ NON-BEARING112"CLEARMINMAX#4 DOWELS @36" O.C.EMBEDDED 24"INTO LOWERWALL (CENTERIN STEMWALL)6"12"Ø ANCHOR BOLTS w/ NUT & 18" THICKx 2"Ø OR SQUARE WASHER SEE 2/FG2FOR SPACING (7" EMBED MIN)-METAL STRAP ANCHORS TO BEINSTALLED AT MANUFACTUREREQUIVALENT SPACINGFLOOR SYSTEM, TYPE,SIZE, AND SPACING TO BEDETERMINED BY OTHERSRIM BOARD OR BRACINGMATERIAL BY OTHERS2x6 SILL PLATE MINIMUMFLOOR TO SILL CONNECTION ATEACH MEMBER SEE TABLE BELOWWASHER TO BE COUNTERSUNKFLUSH w/ TOP OF SILL PLATESEE FULL HEIGHT WALL SECTIONON 5/FG1 FOR FOUNDATION WALLREQUIREMENTSSLOPE GRADE AWAYFROM FOUNDATIONMINTRUSS/JOIST CONNECTION FOR FULL HEIGHT WALLS****BACKFILL TYPECLEAR HEIGHT(SEE 5/FG1)FLOOR MEMBERSPACING16"19.2"A(4) 0.131"Ø x 3" TOP NAILS AT EACH MEMBERSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)24"16"19.2"24"16"19.2"24"AAAAAAABAABBBBBCCCDDDDDDDCCONNECTION A(4) 0.148"Ø x 3" TOP NAILS AT EACH MEMBERCONNECTION B(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON A35/USP MPA1 OR USP LJC ATEACH MEMBERCONNECTION CCONNECTION D(2) 0.131"Ø x 3" TOP NAILS & MECHANICAL CLIPS : SIMPSON FWANZ* OR USP LJQ**OR (2) SIMPSON A35s***/(2) USP MPA1s*** AT EACH MEMBER12"Ø ANCHOR BOLT AND NON-BEARING WALL BLOCKING SPACING FOR FULL HEIGHT WALLS*ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/FG1)BACKFILL HEIGHT(SEE 5/FG1)7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS72"* 12"Ø EPOXIED THREADED ROD w/ 6" EMBED MAY BE USED AT SPACING SHOWNSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS72"72"72"72"72"72"72"72"72"72"72"72"48"60"72"48"60"72"36"48"72"36"36"72"72"72"48"24"24"ALTERNATIVE ANCHOR SPACING FOR FULL HEIGHT WALLS**ALTERNATIVE TO CODE TABLE R404.1.(1)BACKFILL TYPECLEAR HEIGHT(SEE 5/FG1)BACKFILL HEIGHT(SEE 5/FG1)7'-6"7'-0"8'-6"8'-0"7'-0" OR LESS9'-6"9'-0"8'-0"7'-0" OR LESS48"** APPLIES TO 12"Ø EXPANSION BOLT w/ 6" EMBED, 12"Ø SELF-CUTTINGANCHOR BOLT w/ 4" EMBED, OR SIMPSON FWAZ ANCHORSAND(30 PSF/FT)SANDY CLAY(45 PSF/FT)CLAY(60 PSF/FT)6'-0" OR LESS60"72"30"36"72"18"24"42"72"72"24"18"20"24"18"24"24"30"42"16"12"14"16"12"16"36"36"N/AN/ASLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONSLOPE GRADEAWAY FROMFOUNDATIONNOTE: INCREASE STRIP FOOTING WIDTH AT ALL WALLS SUPPORTING MORE THAN 6'-0" OF VENEER.WIDTH TO INCREASE BY THICKNESS OF VENEER MULTIPLIED BY NUMBER OF STORIES.* FWANZ TO BE USED WITH A MIN. 118" OSB RIM AND LOCATED w/IN 5" OF EACH MEMBER. WITH FLOOR TRUSSES,FWANZ MUST BE IN CONTACT WITH A TRUSS OR A MINIMUM 2x4 CONTINUOUS BOTTOM BRACE MUST BE IN PLACE.** LJQ IS TO BE APPROPRIATELY SIZED BASED ON MEMBER WIDTH.*** MEMBER MUST BE A MINIMUM OF 3" WIDE FOR PLACEMENT OF (2) SIMPSON A35s/(2) USP MPA1s.****CONNECTIONS ARE CLASSIFIED A TO D, WITH D BEING THE STRONGEST. IT IS ACCEPTABLE TO USE ASTRONGER CLASS CONNECTION THAN NOTED IN THE TABLE ABOVE.2x8 SILL PLATE TO BE USED w/MAXIMUM OF 112" OVERHANG(MAINTAIN 234" EDGE DISTANCETO BOTH CONCRETE AND INSIDEOF SILL PLATE) - VERTICAL LOADTRANSFER BY SUPPLIERNAIL SHEATHING TO BLOCKING/JOISTS0.131 Ø x 3" LONG NAILS @ 6" O.C.STRUCTURAL RIM BOARD BY OTHERSTYPE D CONNECTOR@ BLOCKING SEE 1/FG22 x 6 MINSILL PLATEFOUNDATION WALL SEE OTHER SHEETSFOR ANCHORS & WALL INFOSLOPE GRADE AWAY FROMFOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MINSPACERS UNTIL SPACES IN WHICH FULLHEIGHT BLOCKING CAN BE INSTALLED,TOE NAIL TO FLOOR MEMBERS EACH ENDw/ (12) 0.131"Øx3" LONG NAILSFRAMINGBY OTHERSOPTIONAL OPEN SPACE AS SHOWNOR SHIFT FULL HEIGHT BLOCKINGPROVIDE BLOCKINGAS REQUIRED TO ACHIEVENAILING SHOWN. (MIN 2SPACES) BLOCKING HEIGHTTO MATCH JOIST DEPTH &BE OF LUMBER, I-JOIST, OROTHER MANUFACTUREDMATERIAL ATTACHBLOCKING TO JOISTS w/ TOENAILS EACH ENDJOISTS BY OTHERSSEE 2/FG2 FOR SPACING OFBLOCKING SYSTEM SHOWNNOTES:1.MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x3" LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2.NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3.BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTHMEMBER BLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD.NAILING SHOWN IS TO BE USED AT MINIMUM.4.BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5.HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.NAIL SHEATHING TO BLOCKING/TRUSSESw/ (12) 0.131"Øx3" LONG NAILSDUCT/MECHANICAL (AS REQUIRED)BY OTHERSFRAMINGBY OTHERS0.131 Ø x 3" LONGNAILS @ 6" O.C.RIM TRUSSBY OTHERSTOP NAIL RIM TO SILLw/ MIN OF (12)0.131 Ø x3" LONG NAILS EACHSIDE OF BLOCKING ORTYPE D CONNECTOR @BLOCKING SEE 1/FG22 x 6 MINSILL PLATEFOUNDATION WALL SEEOTHER SHEETS FORANCHORS & WALL INFOSLOPE GRADE AWAYFROM FOUNDATIONIF REQUIRED, PROVIDE 2 x 4 MIN SPACERSTOP & BOTTOM AT MECHANICAL UNTILSPACES IN WHICH BLOCKING CAN BEINSTALLED, TOE NAIL TO FLOOR MEMBERSw/ (2) 0.131 Ø x 3" LONG NAILS3/4" PLYWOOD/OSB ONE SIDEOF BLOCKING w/ (6) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMOR 1/2" PLYWOOD/OSB EACHSIDE OF BLOCKING EACH w/(4) 0.131 Ø x 3" LONG NAILS TOP & BOTTOMPROVIDE 2 x 4 MIN BLOCKINGTOP & BOTTOM OF TRUSSESAS REQUIRED TO ACHIEVENAILING SHOWN.INSTALL w/ (2) 0.131 Ø x 3"LONG TOE NAILSTRUSSES BY OTHERSNOTES:1.MAIN LEVEL FLOOR SHEATHING TO BE 34" PLYWOOD/OSB PLACED IN STAGGERED PATTERN NAILED w/ 0.131"Ø x 3"LONG NAILS @ 6" O.C. AT PANELS EDGES & @ 12" O.C. @ PANEL INTERIOR SUPPORTS OF EQUIVALENT.2.NAILS IN BLOCKING ARE TO BE PLACED SUCH THAT THE WOOD DOES NOT SPLIT.3.BLOCKING MEMBERS SHOWN MAY BE REPLACED WITH PRE-MANUFACTURED TRUSS STYLE OR FULL DEPTH MEMBERBLOCKING SUCH AS I-JOIST OR LVL DESIGNED FOR 1,500 POUND LATERAL COMPRESSIVE LOAD. NAILING SHOWN IS TOBE USED AT MINIMUM.4.BLOCKING DOES NOT HAVE TO BE PLACED IN ADJACENT BAYS. IF REQUIRED USE ADDITIONAL 2x4 SPACERS ASSHOWN IN FIRST SPACE.5.HOLES MAY BE INSTALLED IN BLOCKING IF REQUIRED UP TO 4" IN DIAMETER, MAINTAIN 3" EDGE DISTANCE.SEE 2/FG2 FOR SPACING OFBLOCKING SYSTEM SHOWN10'-0" MAX 3'-0" MAX GRADE HEIGHT ABOVE TOP OF SLAB 1'-6" MIN 3'-0" EACH WAY MIN112" TYP SLOPE GRADE AWAYFROM FOUNDATION#4 HORIZONTAL BARS @12" O.C. CENTERED INWALLS LAP AROUNDCORNERS AND HOOKINTO FOUNDATION WALL@ EACH SIDE (REFER TO5/FG1 FOR HORZ. BARREQUIREMENTS w/ 8"C.I.P. WALLS)6" MIN C.I.P.CONCRETE WALL#4 VERTICAL BARS @EACH OUTSIDECORNER OF WELL(1)#4 x2'-0" DOWEL @EACH OUTSIDECORNER OF WELL (5"MIN EMBED)12" WIDE x 8" THICK MINSTRIP FOOTING(1) #4 HORIZONTALBAR AT TOP OF WALL(2) #4 HORIZONTAL BARSTOP & BOTTOM OFLINTEL EXTEND 24" MINPAST OPENING EACHEND (WOOD OR STEELOPTION BY OTHERS)WALL BEYONDPLACE (2) #4 VERTICALBARS FULL HEIGHT ANDONE ANCHOR w/IN 12" OFOPENING EACH END8" MIN C.I.P.CONCRETE WALLSLAB-ON-GRADEUNREINFORCED CONCRETESTRIP FOOTING SEE FULLHEIGHT WALL SECTION 5/FG1LOOKOUTWALLSEE 3/FG1GRANULARMATERIAL(SAND)SLOPEWINDOW WELLLADDER/ESCAPEMEANS BYOTHERS5'-0" EACH WAY MAXFLOOR SYSTEM BY OTHERS(DO NOT PLACE GIRDERS ORBEAMS OVER CONCRETE LINTELDESIGNED FOR 1500 PLF)IF CONCRETEOPTIONAL RIGID INSULATION w/IN WINDOW WELL ATTHE DISCRETION OF THE BUILDER FOR ADDITIONALFROST PROTECTION AS REQUIRED PER SITE DESIGN6"MIN.BACKFILL HEIGHT (NOT TO EXCEED 10'-0")SEE 5/FG1 FOR TYPICALFOUNDATION WALL &FOOTING CONSTRUCTIONMAINTAIN MIN. 6" WIDESTEMWALL WITHEXTERIOR LEDGEWOOD FLOORSYSTEM BY OTHERSBACKFILL BELOW EXTERIORSTOOP SLABS WITH COMPACTEDGRANULAR MATERIAL TO FROSTDEPTH (4'-0" MINIMUM)FLASHING &WATERPROOFINGBY OTHERSSTOOP SLAB BY OTHERS* SEE 1/FG2 FOR FLOORTO SILL CONNECTION112" CLEARBUILD UP w/ RIGIDINSULATION BELOW SLABTO MAINTAIN 10'-0" MAX.BACKFILL HEIGHT ASREQ'D OR PROVIDE SITESPECIFIC ENGINEERING(MAY SUBTRACT 6" FOR USE IN TABLE LIMITS FOR SANDY CLAY & CLAY SOILS DUE TO GRANULAR FILL BELOW STOOP SLAB) * MODIFIED CLEAR HEIGHT* SEE REBAR TABLE 6/FG1FOR VERTICAL REBAR* SEE 2/FG2 FOR ANCHOR BOLTS* FOR REBAR TABLE 6/FG1, FLOOR TO SILL CONNECTION TABLE 1/FG2, AND ANCHOR BOLT TABLE 2/FG2USE MODIFIED CLEAR HEIGHT OF 9'-0" IN TABLES FOR BACKFILL HEIGHTS UP TO 8'-6" ANDUSE MODIFIED CLEAR HEIGHT OF 10'-0" IN TABLES FOR BACKFILL HEIGHTS UP TO 9'-6"(MAY REDUCE BACKFILL HEIGHT BY 6" FOR USE IN TABLE LIMITS FOR SANDY CLAY AND CLAY SOILS)8'-0" OR LESS9'-0" MAX.10'-0" MAX.8'-0" OR LESS9'-0" MAX.10'-0" MAX.8'-0" OR LESS9'-0" MAX.10'-0" MAX.5851 Cedar Lake RoadSuite 202St. Louis Park, MN 55416Tel 612-708-3572www.hansongroupmn.comD R Horton 20860 Kenbridge Court #100Lakeville, MN 55044 Customer:Job Name:Plan/Model#:DR HortonX304 Elder SOG DAddress //Lot:City, State:, MNJob#:Subdivision:Scale:Prepared By:Lyman Lumber Co.18900 West 78th StreetChanhassen, MN#952-470-4800Sheet: 1 of 3 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Mitch W.Checked By:Justin H.Release Date:1-25-24Revision Date:1-29-24Lack of proper bracing during construction can result in serious accidents. Observe the following guidelines: WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut Lines Rim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks of Weyerhaeuser NR. © 2014 Weyerhaeuser NR Company. All rights reserved. 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. For A3.1-A3.3 installation specifications see Rim Board Details and Installation in Weyerhaeuser Installation Guide for Floor and Roof Framing, TJ-9001. Plate nail - 16d (0.135" x 312") at 16" on-center* Toe nail - 10d (0.131" x 3") at 6" on-center* When sheathing thickness exceeds 78", trim sheathing tongue at rim board Web Stiffeners required each side at A3._W A3 A3.2A3.1 A3.3 A3W W A3.1 W A3.2 W A3.3 * Floor panel nail - 8d (0.131" x 212") at 6" on-center* 118" TJ® Rim Board, (A3.1/A3.1W only) 114" or 1 12" TimberStrand® LSL. Load bearing or braced/shear wall above (must stack over wall below) Blocking panel: 118" TJ® Rim Board, 114" TimberStrand®LSL or TJI® joist. Web stiffeners required on both sides at B1W and B2W ONLY B1WB1 B2 B2W 116" 2x4 minimum squash blocks Blocking panels may be required with braced/shear walls above or below — see detail B1 TJI® 560 floor joist Top View NAILING AT BEARING (FLOOR) 134" minimum end bearing single-family applications TJI® Joist to Bearing Plate 118" TJ® Rim Board, 114" or 1 12" TimberStrand® LSL. or TJI® 110 rim joist: One 10d (0.131" x 3") nail into each flange TJI® 210, 230, and 360 rim joist: One 16d (0.135" x 312") nail into each flange. With depths > 16", use TJI® 360 rim joist. Shear transfer: Connections equivalent to floor panel nailing schedule TJI® 560 rim joist: Toe nail with 10d (0.128" x 3") nails, one each side of TJI® joist flange Rim to TJI® Joist Squash Blocks to TJI® Joist (Load bearing wall above) One 10d (0.128" x 3") nail into each flange 118" TJ® Rim Board or 114" or 1 12" TimberStrand® LSL. Also see detail B2 Locate rim board joint between joists. 134" minimum bearing One 8d (0.113" x 212") nail each side. Drive nails at an angle at least 112" from end. 312" minimum intermediate bearing 514" may be required for maximum capacity Use 2x4 minimum squash blocks to transfer load around TJI® joist CS Load from above 2x4 minimum squash blocks 116" Blocking panel: 118" TJ® Rim Board, 114"or 112" TimberStrand® LSL, or TJI® joist End of joists at centerline of support B4 Load bearing or braced/shear wall above (must stack over wall below when present) B4W Web stiffeners required on both sides of both joist ends at B4W ONLY Hanger Backer Block: Install tight to top flange (tight to bottom flange with face mount hangers). Attach per the table below. Clinch nails when possible. H2 Backer block both sides of web with single TJI® joist Double TJI® Joist Filler Block: Attach per the table below. Clinch nails when possible. With top mount hangers, backer block required only for downward loads exceeding 250 (395 factored) lbs or for uplift conditions. For filler and backer block sizes see Weyerhaeuser Installation Guide for Floor and Roof Framing, TJ-9001. TJI® Depth, D TJI® Flange Width Block Type Nail Size Quantity 912" <D< 20" 20" <D< 24" less than 312" 312" 312"Filler Backer 16d(0.135" x 312") 10d(0.128" x 3") 25 - each side 15 Filler Backer 16d(0.135" x 312") 10d(0.128" x 3") 15 - each side 15 Filler Backer 10d(0.128" x 3") 15 1510d(0.128" x 3") For nailing capacities refer to TB-834 (ASD) and TB-861 (LSD) For triple TJI® joist header conditions refer to Weyerhaeuser Technical Bulletin TB-820 WARNING Joists are unstable until braced laterally. Safety bracing required during installation. rim board closure 1 1/8" iLevel along panel edges and in field Additional connections may be required to transfer lateral loads from wall above. Attach with 8d (2 1/2" box) nails @ 6" o.c. 24/16 span rated sheathing (7/16" min.) iLevel rim board or 2X8 (min)solid sawn nailed to top plate Maximum 1 1/8"x4 1/2" (min.) 8d (2 1/2" box) nails @ 6"o.c. 2x plate -Joist must be sized properly for vertical loading (Block must be full length between joist (Verify with building official if pressure treated plywood is required due to distance from ground) Lateral load transfer due to wind or seismic loads for this detail is 180 PLF (pound per linear foot) meeting conventional construction building practices TJI® Joist and tight to each flange) -See details in iLevel specifiers guide for all other requirements EXTERIOR DECK ATTACHMENT Structural exterior sheathing See fastener table below. Maintain 2" distance (minimum) from edge of ledger to fastener. LA Flashing Treated 2x_ ledger 118" TJ® Rim Board or 114" or 112" TimberStrand®LSL. (1) Corrosion-resistant fasteners required for wet-service applications. (2) Allowable load determined in accordance with ASTM D7672. (3) 118" TJ® Rim Board is allowed with joist depths < 16" only. (4) Maximum 12" shimmed air space. Fastener Allowable Load (lbs/bolt) 480 12" lag bolt 118" TJ® Rim Board Rim Board Material 1 14" TimberStrand® LSL 1 12" TimberStrand® LSL 610 675 695 12" Through bolt 725 725 12" Through bolt with Air Space 615 (2) (3) (4) _ W Web stiffener both sides. See table below. 2x4 Minimum Web Stiffener Size 58" x 2516" 34" x 2516" 78" x 2516" 560 Tight fit* 110 210 230 & 360 End 3 WEB STIFFENER ATTACHMENTGap*: 18" minimum 234" maximum TJI® Joist Series Type 8d (0.113" x 212") 1" (112" for TJI® 560, 560D) * With point load from above, and no support below, install web stiffener tight to top flange (gap at bottom flange) All Depth (in.) 560D All All All 18" 20" 22" 24" 2x4 Nailing Requirements 16d (0.135" x 312") 16d (0.135" x 312") 3 Number Nails Intermediate 4 5 6 6 4 5 11 13 (2) (2) (1) (1) (1) Nailing: See table below. (1) PS1 or PS2 sheathing, face grain vertical (2) Construction grade or better (3) Web stiffeners are always required for 22" and 24" TJI® 560D Joists (3) (3) Floor panel nail - 8d (0.131" x 212") at 6" on-center Toe nail - 10d (0.131" x 3") at 6" on-center Install proper blocking to support all panel edges Sheathing boundry nails, 8d (0.131 x 212") at 4" o.c. For additional installation specifications see Rim Board Details and Installation in Weyerhaeuser Installation Guide for Floor and Roof Framing, TJ-9001. A3.4 12" min. 2x_ stud wall at 16" on-center Plate nail, 16d (0.135" x 312") at 12" on-center When sheathing thickness exceeds 78", trim sheathing tongue at rim board A3.4 W Web stiffeners required on both sides at A3.4W ONLY For rim board thicker than 134" - Attach TJI Joist to rim board with one 10d (0.128" x 3") nail. Top nail from TJI joists into rim board. - Connect corner with four 10d (0.128" x 3") nails. Toe nail from side of parallel closure into rim board. 114" or 1 12" TimberStrand®LSL rim board. 8" diameter maximum hole for 1178" - 16" deep blocking panels; 6" diameter maximum for blocking panels 912" deep or shorter than 12" long. Do not cut flanges. Attach reinforcement to joist flange with 8d (0.131" x 212") nails at 6" on-center. When reinforcing both sides, stagger nails. E3E2 2 '-0 "m a x im u m Face grain horizontal 4'-0" length of 34" reinforcement on one side at E2, both sides at E3 118" TJ® Rim Board or 114" or 112" TimberStrand® LSL. Nail with 10d (0.131" x 3") nails, one each at top and bottom flange. 2 '-0 " m a x im u m Not for use with 312" TJI® joist flange widthsE4 Attach reinforcement to joist web with 3 rows 10d (0.148" x 3") nails at 6" on-center, clinched. Use 2 rows with 912" and 1178" TJI® joists. 8" diameter maximum hole for 1178" - 16" deep blocking panels; 6" diameter maximum for blocking panels 912" deep or shorter than 12" long. Do not cut flanges. 6'-0" length of TJI® joist reinforcement and filler block. Use 4'-0" length with 912" and 1178" TJI® joists. 118" TJ® Rim Board 114" or 112" TimberStrand® LSL. Nail with 10d (0.131" x 3") nails,one each at top and bottom flange. Top mount hanger H1 Face mount hanger Web stiffeners required if sides of hanger do not laterally support at least 38" of TJI® joist top flange Hanger height must be a minimum of 60% of joist depth L6 Multiple pieces can be nailed or bolted together to form a header or beam of the required size, up to a maximum width of 7" Load must be applied evenly across entire beam width. Otherwise, use connections for side-loaded beams. When fasteners are required on both sides, stagger fasteners on the second side so they fall halfway between fasteners on the first side. (1) 10d nails are 0.128" diameter; 12d-16d nails are 0.148" - 0.162" diameter; screws are SDS, SDW, USP WS, or TrussLOK® (2) An additional row of nails is required with depths of 14" or greater. (3) When connecting 4-ply members, nail each ply to the other and offset nail rows by 2" from the rows in the ply below. Piece Width # of Plies Fastener Type Min. Length # Rows O.C. Spacing Location 10d nails 3" 312" 134" 2 3 4 2 12d-16d nails Screws 10d nails 12d-16d nails Screws 10d nails 12d-16d nails Screws Screws 12" bolts (1) (3) (3) 3 14" 338" or 312" 3" 3 14" 338" or 312" 5" 3" 3 14" 5" or 6" 6 34" 5" or 6" 6 34" 8" 3 2 2 3 2 2 3 2 2 2 2 12" 24" 12" 24" 12" 24" 24" 24" One side Both sides One side Both sides One side(per ply) Both sides One side Both sides One side - (2) (2) (2) (2) (2) (2) Fastener Installation Requirements Multiple-Member Connections for Top-Loaded Beams Option #2: 2x_ strapping installed at 13 joist-span locations using two 212" screws per joist, typical Option #1: TJI® joist blocking with end blocks installed at 13 joist-span locations using two 8d (0.113" x 212") nails or 212" screws, typical PB1 Option #3: Directly applied ceiling When specified on the layout, one of the bracing options above is required Apply subfloor adhesive to all contact surfaces 8 ' m a x .1 3 jo is t s p a n DO NOT cut, notch or drill holes in headers or beams except as indicated in illustrations and tables. DO NOT cut or notch flange. DO NOT cut holes in cantilever reinforcement. 112" hole may be cut anywhere in web out- side of hatched zone Min. distance from Table ANo field cut holes in hatched zones Minimum distance from edge of hole to inside face of nearest end support minimum (applies to all holes except knockouts) Table A - End Support 6" 6"1L 12 x D 1D DL 2 x L minimum 2 2 6" 6" 2 ALLOWABLE HOLES - TJI® Joists 1.3E TimberStrand®LSL allowed hole zone dd Microllam®LVL and Parallam® PSL allowed hole zone middle 13 span 1.3E TimberStrand® LSL hole zone Microllam®LVL and Parallam® PSL hole zone 2 x diameter of the largest hole (minimum) d 13 depth 1" 2" 134" Maximum Round Hole Size Header or Beam Depth 438" 714"- 20" 512" See illustration for Allowed Hole Zone Other Trus Joist® Headers and Beams 1.55E TimberStrand®LSL Headers and Beams ALLOWABLE HOLES - Headers and Beams 13 depth 2 x diameter of the largest hole (minimum) 8" See illustration for allowed hole zone 1114"-11 78" 14"-16" 914"-912" 358" 458" 3" No holes in headers or beams in plank orientation. Round holes only General Notes General Notes No holes in headers or beams in plank orientation. Allowed hole zone suitable for headers and beams with uniform loads only. Round holes only No holes in cantilevers. Allowed hole zone suitable for headers and beams with uniform and/or concentrated loads. Maximum Round Hole Size Header or Beam Depth 8" Allowed hole zone Min. distance from Table BDo not cut holes larger than 112" in cantilever 6"Closely grouped round holes are permitted if the group perimeter meets requirements for round or square holes. 10'-0" 11'-6"3'-0"1'-0"1'-0" 1'-6" 9'-0"9'-0"6'-6"4'-6"1'-0" 1'-0"1'-0"360 1'-0" 12'-0" 17" 13" 15'-6" 15'-6" SQUARE OR RECTANGULAR HOLE SIZE Minimum distance from edge of hole to inside face of nearest intermediate or cantilever support 16'-6" 16'-0" 21'-0" 20'-6" 18'-0" 17" 17'-0" For simple span (5' minimum), uniformly loaded joists used in residential applications, one maximum size round hole may be located at the center of the joist span provided that no other holes occur in the joist. Distances are based on the maximum uniform loads from current Trus Joist specifier's guides. For other load conditions or hole configurations use Forte® software or contact your Weyerhaeuser representative. 15"8" 10"6"4"12"17"15"12"10"8"6"4" 16'-0" 15'-6" Holes may be located vertically anywhere within the web. Leave 18" of web (minimum) at top and bottom of hole. Knockouts are located in web at approximately 12" on-center; they do not affect hole placement. 1'-0" 1'-0" 1'-0" 1'-0" Rectangular holes based on measurement of longest side. 18" 20"1'-0"560 560 360 360 1'-0" 1'-0" 1'-0" 1'-0" 1'-6" 1'-0" 2'-0" 3'-0" 3'-0" 6'-0" 6'-0" 12'-0"5'-6" 16'-6" 11'-0" 15'-0" 10'-0" 6'-0" 9'-0" 6'-0" 3'-0" 1'-6" 4'-0" 1'-0" 1'-0" 1'-0" 1'-0" 16'-6" 18'-0" 16'-6" 14'-0"8'-6" 7'-0" 9'-0" 11'-6" 16'-6" 12'-6" 14'-6" 19'-6"17'-6' 19'-0" 20'-0" 19'-6" 10'-0" 17" 11'-0" 13" 10'-6" ROUND HOLE SIZE Table B - Intermediate or Cantilever Support 11'-0" 10'-0" 15'-0" 13'-6" 4'-0" 8'-6"2'-6"230 3'-0" 1'-0" 1'-0" 1'-0" 1'-0" 3'-0" 3'-0" 1'-0" 1'-0" 4'-0" 1'-0" 2'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 16" 14" 230 560 360 1'-0" 1'-0" 1'-0" 230 560 210 360 1'-0" 1'-0" 1'-0" 1'-0" 1178"1'-0"230 360 110 210 560 2'-0" 1'-0" 1'-6" 360 210 110 3'-0" 1'-0" 1'-0" 9'-6"5'-6"1'-0" 2'-6" 1'-0" 1'-0" 1'-0" 1'-6" 2'-6" 3'-0" 1'-0" 1'-0" 1'-6" 2'-0" 1'-0" 5'-6" 5'-6" 3'-6" 11'-0" 10'-0" 4'-0" 7'-0" 6'-6" 6'-6" 10'-6" 13'-6" 12'-6" 6'-0" 9'-6" 3'-6" 8'-6" 6'-0" 2'-6" 5'-0" 4'-0" 1'-0" 4'-6" 7'-0" 2'-0" 8'-0" 5'-6" 2'-0" 1'-6" 4'-6" 4'-0" 9'-0" 10'-0" 11'-0" 4'-6" 12'-0" 8'-6" 9'-0" 8'-6" 6" 3" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 2'-6" 2'-6" 912" TJI® 210 110 2" 2'-0" 2'-0" 18" 20" 1'-0"360 560 560 360 1'-0" 1'-0" 1'-0" 560 1'-0" 4" 4" 3'-6" 3'-6" 612" 8'-0" 7'-6" 878" 11" 1'-0" 2'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 8"10" 1'-0" 10'-0"5'-0" 11'-0"5'-0" 1'-0" 2'-0" 7'-0" 7'-0" 5'-0" 12" 7'-6" 15" 7'-6"3'-6"2'-0" 4'-6" 4'-6" 2'-0" 1'-6" 3'-6" 2'-6" 1'-0" 1'-0" 1'-0" 3'-0" 1'-0" 1'-0" 2'-0" 4'-6" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 2'-0" 1'-0" 3'-0" 3'-0" 1'-0" 1'-0" 13'-0"6'-0"2'-0" 10'-0" 10'-6" 13'-6" 12'-0" 11'-0" 14'-6" 13'-0" 1'-0" 3'-6" 2'-0" 5'-0" 9'-0" 7'-6" 1'-0" 5'-0" 4'-0" 2'-6" 6'-6" 4'-6" 10'-0" 9'-0" 13'-6" 16'-0" 14'-6" 13'-6" 12'-6" 15'-0" 14'-0" 10'-0" 12'-0" 11'-0" 10'-6" 10'-0" 8'-6"3'-6" 5'-0" 1'-0" 6'-0" 9'-6" 5'-0" 10'-6" 5'-6" 3'-0" 2'-6" 8'-0" 8'-0" 7'-0" 12'-0"9'-0" 9'-6" 2'-0" 6" 1'-6" 1'-0" 1'-0" 3" 1'-0" 3'-0" 2'-6" 2'-0" 1'-6" 2" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 4" 4'-0" 3'-6" 4"612" 7'-6" 6'-6" 11"878" 10'-0" 12'-0" 11'-6" 11'-0"10'-0"5'-0" 6'-6" 4'-0" 2'-6" 11'-0" 9'-6" 8'-0" 3'-0" 8" 4'-6" 10" 13'-6" 14'-6" 14'-6" 14'-0" 12'-6' 11'-0" 15"12" 13" 11'-0" 11'-0" SQUARE OR RECTANGULAR HOLE SIZE 13" 6'-0" 7'-0" ROUND HOLE SIZE 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-6" 2'-0" 2'-0" 1'-6" 1'-6" 1'-0" 1'-6" 1'-0" 2'-0" 2'-6"1'-6"560 16" 14" 1'-0"360 210 230 560 1'-0" 1'-0" 1'-0" 210 230 110 1'-0" 1'-0" 1'-0" 1178" 912" 110 230 360 210 1'-0" 1'-0" 1'-6" 1'-0" 110 230 360 210 1'-0" 1'-6" 1'-6" 1'-0" 8'-0"3'-0" 4'-0" 1'-6" 1'-0" 1'-0" 2'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-6" 8'-0"5'-6" 2'-6" 3'-0" 6'-6" 3'-6" 4'-0" 9'-0" 3'-6" 4'-0" 3'-0" 6'-0" 7'-0" 5'-6" 1'-6" 2'-0" 3'-0" 2'-0" 2'-0" 3'-6" 2'-6" 2'-0" 2'-0" 2'-6" 3'-0" 2'-6" 4'-0" 3'-6" 3'-0" 3'-0" 5'-6" 6'-6" 7'-0" 6'-0" 3" JOIST DEPTH TJI® 2" 4" 8 78" 11" 1'-6" 2'-0" 1'-6" 2'-6" 2'-0" 2'-0" 3'-6" 2'-6" 1'-0" 1'-6" 1'-0" 1'-0" 1'-6" 1'-0" 1'-0" 3'-0" 2'-6" 1'-0" 1'-0" 1'-0" 1'-6" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-6" 1'-0" 1'-0" 1'-0" 1'-6" 1'-0" 5'-6"4'-6" 8'-0" 4'-0"2'-6" 1'-0" 1'-0" 4'-0" 2'-0" 2'-0" 5'-0" 2'-0" 1'-6" 2'-0" 3'-0" 2'-6" 2'-0" 9'-6"8'-0" 9'-0" 8'-0" 10'-0" 7'-0" 6'-6" 9'-0" 9'-0" 8'-6" 8'-0" 7'-0" 6'-0" 6'-6" 2'-0" 3'-6" 2'-6" 2'-6" 2'-6" 4'-6" 3'-6" 3'-0" 3'-6" 3'-0" 2'-6" 2'-6" 3'-6" 5'-0" 4'-6" 4'-0" 7'-6" 7'-0" 6'-6" 6'-0" 3"2" 4" 11"878"612" 5'-6" 5'-0" 5'-6" 6'-0" 3'-0" 3'-0" 4'-6" 2'-6" 2'-0" 2'-6" 1'-6" 4'-6" 1'-0" 1'-6" 3'-6" 5'-6" 2'-6" 2'-6" 612" 4'-6" 5'-0" 5'-0" 5'-6" 5'-0" 5'-6" 6'-6" 4'-6" 3'-6" 4'-0" 4'-0" 7'-0" 3'-6" 3'-0" 6'-0" 7'-0" 6'-6" 5'-0" 3'-6" 3'-6" 5'-0" 3'-0" 2'-6" 2'-6" 2'-0" 5'-0" 1'-6" 1'-6" 4'-0" 6'-0" 3'-0" 2'-6" 5'-6" 5'-6" 6'-6" 5'-0" 4'-0" 4'-6" 5'-0" 7'-6" 4'-0" 3'-6" 6'-6" 7'-6" 7'-0" 5'-6" 5"5"7"7" 1'-6" 2'-6" 3'-0" 5" 4'-6" 5'-0" 2'-6" 3'-0" 6'-6" 5'-6" 1'-0" 5'-6" 3'-6" 3'-6" 3'-6" 1'-0" 2'-0" 1'-0" 1'-0" 1'-0" 1'-0" 5'-6" 7" 4'-6" 3'-0" 2'-0" 3'-6" 4'-0" 4'-0" 1'-0" 6'-6" 6'-0" 5'-6" 7'-6" 2'-6" 8'-6" 5'-0" 7"5" 5'-6" 6'-6" 3'-6" 2'-6" 5'-6" 4'-0" 4'-0" 1'-6" 7'-0" 5'-6" 5'-0" 7'-0" 2'-6" 8'-0" 7'-6" 4'-6" 4'-0" 6'-6" 8'-0" 11'-0" 6'-0" 9'-6" 9'-0" 10'-0" 11'-0" 5'-6" 7'-6" 8'-6" 10'-0" 6'-0" 7'-0" 7'-0" 5" 1'-0" 1'-0" 1'-0" 1'-0" 7" 1'-0" 1'-0" 1'-0" 1'-0" 5" 7" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 3'-0" 4'-0" 5" 1'-0" 1'-0" 1'-0" 1'-0" 1'-6" 1'-0" 1'-0" 1'-0" 7"5" 1'-0" 1'-0" 3'-6" 1'-6" 6'-6" 4'-0" 6'-0" 8'-6" 7" JOIST DEPTH FILLER and BACKER BLOCK SIZES (1) If necessary, increase filler and backer block height for face mount hangers and maintain 18" gap at top of joist; see detail W. Filler andbacker block dimensions should accomodate required nailing without splitting (12" minimum for backer blocks and 24" minimum for filler blocks). 2x10 6'-0" long 110TJI® Joists Cantilever Filler (Detail E4) Filler Block (1) (Detail H2) Backer Block (1) (Detail F1 or H2) 2x6 4'-0" long 58" or 34" Depth 2x6 2x8 912" or 1178"14" 210 230 or 360 560 1178" Two 2x6 2x6 2x6 + 12" sheathing 4'-0" long 912" or 1178" 2x6 + 12" sheathing 2x6 + 38" sheathing 4'-0" long 2x10 + 38" sheathing 6'-0" long 34" or 78" 2x8 + 38" sheathing 2x6 + 38" sheathing 912" or 1178" 14" or 16" 2x10 + 12" sheathing 6'-0" long 78" or 1" Net 2x8 + 12" sheathing 14" or 16" 2x12 + 12" sheathing Not applicable 18" or 20" 2x122x8 18" or 20" Two 2x12 Not applicable Two 2x8 14" or 16" 1.5E TimberStrand®LSL Prescriptive Chart 13 depth 2 x diameter of the largest hole (minimum) 8" See illustration for allowed hole zone 1114"-11 78" 14"-16" 914"-912" 358" 458" 3" Round holes only General Notes No holes within 8" of joist ends. Maximum Round Hole SizeJoist Depth Allowed hole zone 1.5 E TimberStrand® LSL 8" Round holes larger than 3-5/8" up to 7-1/4" max. in 1.5" x 11-7/8" 1.5E TimberStrand LSL joist only Edge of large holes need to be at least 4 times the diameter of the largest hole (for a 7-1/4" hole, the closest distance allowed to the next hole is 29", even if the next hole is a small 12" diameter hole). The hole must be centered within the joist vertically. No square or rectangular holes No more than (2) holes between 3-5/8" and 7-1/4" diameter allowed per span. See chart below for minimum distance from inside face of bearing to edge of hole for holes larger than 3-5/8" but not greater than 7.25" Minimum distance from edge of hole to inside face of bearing (end or intermediate) 4"5"6.5" 7.25" 2'-0"2'-0" 3'-0"3'-6" the area of a 7-1/4" circumscribed hole A smaller hole can be drilled within centered in the depth of the joist circumscribed 7-1/4" hole smaller hole drilled within circumscribed area of 7-1/4" hole assuming the circumscribed hole is a minimum of 3'-6" from face of bearing 1-1/2" x 11-7/8" 1.5E TimberStrand LSL floor joist No load bearing wall above Web stiffeners required each side at B3W ONLY B3WB3 Blocking panels may be required with braced/shear walls above or below — see detail B1 8" diameter maximum hole for 117 8" - 16" deep blocking panels; 6" diameter maximum for blocking panels 912" deep or shorter than 12" long. Do not cut flanges. E1 E1W Web stiffeners required on both sides at E1W ONLY 118" TJ® Rim Board or 114" or 112" TimberStrand® LSL. Nail with 10d (0.131" x 3") nails, one each at top and bottom flange.SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ONTHIS DRAWING. LYMAN COMPANIES WOULD ONLY BE RESPONSIBLE FOR THEINDIVIDUAL MEMBER DESIGN, BASED UPON THE ASSUMED OR KNOWN VERTICALLOADS. THE BUILDER OR GENERAL CONTRACTOR IS RESPONSIBLE FOR THESTRUCURE(S) OVERALL DESIGN, AND IT IS STRONLY RECOMMENDED THAT ALLDRAWINGS AND CALCULATIONS BE REVIEWED BY THE ENGINEER OF RECORD FORTHE PARTICULAR PROJECT. Products PlotID Length Product Plies Net Qty B1 22' 0" 1 3/4" x 16" 2.0E Microllam LVL 2 2 B2 14' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 3 3 B4 8' 0" 1 3/4" x 7 1/4" 1.55E TimberStrand LSL 2 2 B7 8' 0" 2 x 8 SPF No.1/No.2 2 2 Wall Framing PlotID Length Product Plies Net Qty B3 8' 0" 3 1/2" x 9 1/2" 1.55E TimberStrand LSL 1 1 B5 4' 0" 3 1/2" x 7 1/4" 1.3E TimberStrand LSL 1 1 B6 4' 0" 2 x 10 SPF No.1/No.2 2 10 5ft Bumpout Garage Option - Add List PlotID Length Product Plies Net Qty B8 22' 0" 1 3/4" x 18" 2.0E Microllam LVL 3 3 Pt1 10' 0" 5 1/4" x 5 1/4" 1.8E Parallam PSL 1 1 3rd Stall Garage Option - Add List PlotID Length Product Plies Net Qty B8 22' 0" 1 3/4" x 18" 2.0E Microllam LVL 3 3 Pt1 10' 0" 5 1/4" x 5 1/4" 1.8E Parallam PSL 1 1 B9 10' 0" 3 1/2" x 9 1/2" 1.55E TimberStrand LSL 1 1 B2 B4 B1 B7 B5 B6B6B6B6B6B3 B9 B8B8Pt1 Pt1 3rd Stall Garage Option 5ft Bumpout Garage Option D.R. Horton and Energy Star Requirements: -4 stud U corners required for siding and sheetrock backing. -Full depth headers as marked required for load transfer. -Double jack studs as marked under full depth headers required for load transfer. -Cripple studs required for load transfer at both ends of window sill and required for drywall on center spacing.Top of beam flush with top of floor.Top of beam flush with top of floor.Interior Brace Panel 3-2x6 3-2x6 1 Trimmer Each End 3-2x6 3-2x6 2-2x6 2-2x6 2 Trimmers Each End 2 Trimmers Each End 14" Floor Truss 14" Floor Truss 14" Floor Truss Floor truss 14" Floor Truss 4-2x64-2x6 PSL through bottom plate PSL through bottom plate Customer:Job Name:Plan/Model#:DR HortonX304 Elder SOG DAddress //Lot:City, State:, MNJob#:Subdivision:Scale:Prepared By:Lyman Lumber Co.18900 West 78th StreetChanhassen, MN#952-470-4800Sheet: 2 of 3 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Mitch W.Checked By:Justin H.Release Date:1-25-24Revision Date:1-29-24SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ONTHIS DRAWING. LYMAN COMPANIES WOULD ONLY BE RESPONSIBLE FOR THEINDIVIDUAL MEMBER DESIGN, BASED UPON THE ASSUMED OR KNOWN VERTICALLOADS. THE BUILDER OR GENERAL CONTRACTOR IS RESPONSIBLE FOR THESTRUCURE(S) OVERALL DESIGN, AND IT IS STRONLY RECOMMENDED THAT ALLDRAWINGS AND CALCULATIONS BE REVIEWED BY THE ENGINEER OF RECORD FORTHE PARTICULAR PROJECT. Wall Framing PlotID Length Product Plies Net Qty B1 8' 0" 2 x 10 SPF No.1/No.2 2 4 B2 4' 0" 2 x 10 SPF No.1/No.2 2 14 Products PlotID Length Product Plies Net Qty B3 22' 0" Girder by Others 2 2 B2B2B2B2 B2 B1B2B2 B1 B3 D.R. Horton and Energy Star Requirements: -4 stud U corners required for siding and sheetrock backing. -Full depth headers as marked required for load transfer. -Double jack studs as marked under full depth headers required for load transfer. -Cripple studs required for load transfer at both ends of window sill and required for drywall on center spacing. 1 Trimmer Each End 2 Trimmer Each End 1 Trimmer Each End 4-2x6 through top plates Customer:Job Name:Plan/Model#:DR HortonX304 Elder SOG DAddress //Lot:City, State:, MNJob#:Subdivision:Scale:Prepared By:Lyman Lumber Co.18900 West 78th StreetChanhassen, MN#952-470-4800Sheet: 3 of 3 A complete Javelin™ framing plan requires the Framer's Pocket Guide See the Framer's Pocket Guide for Product Trademark Information Drawn By:Mitch W.Checked By:Justin H.Release Date:1-25-24Revision Date:1-29-24SALES PRESENTATION DRAWING:NO STRUCTURAL OR DIMENSIONAL CHECK HAS BEEN PERFORMED ONTHIS DRAWING. LYMAN COMPANIES WOULD ONLY BE RESPONSIBLE FOR THEINDIVIDUAL MEMBER DESIGN, BASED UPON THE ASSUMED OR KNOWN VERTICALLOADS. THE BUILDER OR GENERAL CONTRACTOR IS RESPONSIBLE FOR THESTRUCURE(S) OVERALL DESIGN, AND IT IS STRONLY RECOMMENDED THAT ALLDRAWINGS AND CALCULATIONS BE REVIEWED BY THE ENGINEER OF RECORD FORTHE PARTICULAR PROJECT. DescriptionProject Number:Date:0.108S11Sheets: of1D R Horton 20860 Kenbridge Court #100Lakeville, MN 55044X304 & X324 Elder ModelGarage LeftMinnesota Construction3407 Kilmer Lane NSuite 4Plymouth, MN 55441Tel 612-708-3572www.hansongroupmn.comPLANS SHOWN LIGHT IN BACKGROUND ARE FORLOCATION REFERENCE ONLY. PLAN NOTES ANDELEMENTS SHOWN LIGHT MAY NOT NECESSARILYSUPPORT THE HANSON GROUP'S DESIGN.DateRevisionPrint Name:Signed: License Number:Ryan Mack46673Date:I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota.PARTIAL LOWER LEVEL HOUSE PLANSHOWN FOR LOCATION REFERENCE ONLY1S1REFERENCE PLANTHE REQUIREMENTS SHOWN DIRECTLY ABOVEONLY APPLY TO WALKOUT FOUNDATIONSTHE REQUIREMENTS SHOWN DIRECTLY ABOVEONLY APPLY TO LOOKOUT FOUNDATIONSMAIN LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY2S1REFERENCE PLANCONCRETEFOUNDATIONBELOWSIMPSON HTT5HOLDOWN ANCHOR ATLOCATIONS SHOWN w/12"Ø x 12" LONGSIMPSON TITEN HDSCREW-IN ANCHORPOST-INSTALLED HOLDOWN OPTION6S1FRAMING DETAILCONSTRUCTPORTAL FRAME ASSHOWN IN 4/S1S1FRAMING DETAILGARAGE FRONT PORTAL FRAME4NOTEINFO APPLIES SYMMETRICALLY ACROSS DETAIL.WITH 3-CAR GARAGEPROVIDE DOUBLE STUDS ATEACH END OF SHEARWALL(MAY USE BEARING/KINGSTUDS AS REQ'D)HATCHED AREA INDICATES 716" ORTHICKER PLYWOOD/OSB EXTERIORSHEATHING FASTENED TO STUDS w/8d NAILS @ 6" O.C. AT PANEL EDGES& @ 12" O.C. AT INTERIOR SUPPORTSTYPICAL 2x6 STUDS @ 16" O.C.FASTEN FRAMINGABOVE AS SHOWN FORBRACED WALL PANELSHEADER & BEARING/KINGSTUDS AT SIDES OFOPENINGS BY SUPPLIERSIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 6/S1 FOR ALTERNATIVE OPTIONPERFORATED SHEARWALL5S1FRAMING DETAILNOTEINFO APPLIES SYMMETRICALLY ACROSSDETAIL UNLESS NOTED/SHOWN OTHERWISE.ELEVATION BELEVATION CCONSTRUCTSHEARWALL ASSHOWN IN 5/S1UPPER LEVEL HOUSE PLAN SHOWNFOR LOCATION REFERENCE ONLY3S1REFERENCE PLAN16'-3"±NOT TO EXCEED 12'-0"FASTEN TOP PLATE TO HEADER w/ (2)ROWS 16d SINKER NAILS @ 3" O.C.(1) 2x6 BEARING STUD & (1) 2x6 FULLHEIGHT STUD EACH END OF HEADERLOCATE PANEL JOINT WITHIN 2'-0" FROMCENTER OF HEADER HEIGHT AS REQ'D (2x SOLIDBLOCKING REQUIRED AT SHEATHING JOINT)(2) 2x6 BEARING STUDS MIN.(VERIFY w/ SUPPLIER)PROVIDE 2x6 INFILL WALLABOVE HEADER AS REQ'DFOUNDATION WALL BELOWLENGTH OF CONTINUOUS HEADER(2) 58" Ø ANCHOR BOLTS (7" MIN. EMBED)w/ 2" x 2" x 316" PLATE WASHERSNAIL SHEATHING TO HEADER w/ 8dNAILS @ 3" O.C. EA. WAY TYP.SMALL HATCH AREA INDICATES 716" ORTHICKER PLYWOOD OR OSB SHEATHINGAPPLIED TO EXTERIOR SIDE OF STUDS(NAIL SHEATHING AROUND PERIMETER w/ (2)ROWS 8d NAILS @ 3" O.C. STAGGERED & TOPLATES / BLOCKING @ 3" O.C.)SIMPSON MSTC40 STRAP ON INSIDE FACEOF WALL (PROVIDE SPACER TO FLUSHOUT HEADER TO WALL STUD THICKNESS)FASTEN KING STUD TO HEADER w/(2) ROWS 16d SINKER NAILS @ 3" O.C.LARGE HATCH AREA INDICATES 716" OR THICKERPLYWOOD OR OSB SHEATHING APPLIED TO EXTERIORSIDE OF STUDS w/ STANDARD 6"/12" NAILINGFASTEN FRAMING ABOVE AS SHOWNFOR BRACED WALL PANELS2'-712"±CONTINUOUS LSL/LVL HEADER TOSUPPORT VERTICAL LOADS BY SUPPLIER(MIN.312" WIDTH & MIN.1114" DEPTH REQ'D)SIMPSON STHD14 EMBEDDED HOLDOWNANCHOR AT LOCATIONS SHOWN(REFER TO 6/S1 FOR ALTERNATIVE OPTION(4-FT)(4-FT)(4-FT) (4-FT)(4-FT) (4-FT)(4-FT)(4-FT)(3.5-FT)(3-FT)(3-FT)(3-FT)(3-FT)(3-FT)(4-FT)BRACED WALL LINE BRACED WALL LINEBRACEDWALL LINEBRACEDWALL LINEBRACEDWALL LINEBRACEDWALL LINE(5-FT)(5-FT)(5-FT)(5-FT) (5-FT)(6-FT)(6-FT) (4-FT)(4-FT)(3.5-FT)(9.5-FT)(8-FT)ONE-SIDED(3-FT)(4-FT)(4-FT)BRACED WALL LINE BRACED WALL LINE BRACED WALL LINE BRACEDWALL LINEBRACEDWALL LINEBRACEDWALL LINEBRACEDWALL LINE(3-FT)(3-FT)(6-FT)BRACEDWALL LINE(8-FT)BRACEDWALL LINEApril 27, 20201-3-23COPYRIGHT HANSON GROUP, LLC 2020©THIS SHEET/S REPRESENTS A COMPLETE DESIGN OF THE "MAIN WINDFORCE RESISTING SYSTEM" FOR THE ENTIRERESIDENTIAL STRUCTURE. THE LOCATION AND LENGTH OF EACH BRACED WALL PANEL AND ENGINEERED WINDRESISTING ELEMENT THAT IS REQUIRED FOR THE HANSON GROUP'S DESIGN IS SHOWN ON THE STRUCTURALDRAWINGS. WALLS NOT SPECIFICALLY LABELED ON THE PLANS MAY BE STANDARD FRAMING.SECTIONS SHOWN DEPICT CONNECTIONS OF BRACED WALL PANELS TOROOF TRUSSES ABOVE, TO JOISTS/TRUSSES/BLOCKING ABOVE, AND TOJOISTS/TRUSSES/BLOCKING BELOW. THESE PANELS ARE NOT NECESSARILYREQUIRED TO ALIGN, BUT MAY DEPENDING ON PLAN LAYOUT.ROOFTRUSSESBRACEDWALL PANELFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)SIMPSONA35FRAMINGANGLEEACH END(4) 0.131"Øx 3" NAILSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSPROVIDE 12" WIDTH WEBSTIFFENER FOR ATTACHMENTOF FRAMING ANGLEBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONA35FRAMINGANGLEEACH ENDFLOORJOISTSBRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)FLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACEDWALL PANEL(4) 0.131"Øx 3" NAILSSIMPSONLTP4FRAMINGPLATEEACH ENDFLOORTRUSSESFLAT 2x6 @ 24" O.C.(MIN. (3) PER BRACEDWALL PANEL)BRACED WALL CONNECTIONBRACED WALL CONNECTIONBRACED WALL CONNECTION(ROOF TRUSSES)(FLOOR JOISTS)(FLOOR TRUSSES)DETAILS SHOWN ABOVE AREALTERNATIVE CONNECTIONS TO BEUSED WHEN BRACED WALL PANELDOES NOT ALIGN WITH FRAMING.EXTERIOR NON-BEARING WALLFRAME 2x4 BOXAROUND SPACEBETWEEN TRUSS w/SAME SHEATHINGAND FASTENING ASWALL BELOW(OR REPLACE w/ADEQUATE DEPTH2x MEMBER)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)#12 x 312" WOODSCREWS @ 16" O.C.INSTALLED INADDITION TO NAILS(MAIN/UPPERLEVEL ROOFTRUSS BEARINGWALLS ONLY)EXTERIOR BEARING WALLREPRESENTSFIGURER602.10.8.2(3)INDICATES INTERIOR BRACED WALL PANEL w/ GYPSUMSHEATHING BOTH FACES WITH EITHER FASTENER OPTIONLISTED IN NOTE 3, SPACED AT 4" O.C. PROVIDE INCREASEDFASTENING REQUIREMENTS AS SHOWN BELOW.INDICATES ENGINEERED WIND RESISTING ELEMENTS TOBE CONSTRUCTED AS SHOWN IN THE DETAIL SHEETS.(MIN. LENGTH)INDICATES EXTERIOR BRACED WALL PANEL w/ SHEATHING ONEXTERIOR FACE IN ACCORDANCE w/ NOTE 2. PROVIDEINCREASED FASTENING REQUIREMENTS AS SHOWN BELOW.(MIN. LENGTH)w/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESw/ JOISTSw/ TRUSSESMATERIALSWALL STUDS (10' OR LESS):SPF STUD GRADE OR BETTERWALL STUDS (OVER 10'):SPF NO.2 GRADE OR BETTERDIMENSIONAL LUMBER:SPF NO.2 GRADE OR BETTERTREATED LUMBER:SYP NO.2 GRADE OR BETTERLSL:134" WIDTH - 1.55E OR BETTERLVL:134" WIDTH - 1.9E OR BETTERLOADSROOF SNOW LOAD: 35-42 PSFROOF DEAD LOAD: 15 PSFFLOOR LIVE LOAD: 40 PSFFLOOR DEAD LOAD: 15 PSFWIND LOAD:115 MPH ULTIMATE EXP. BCODE2020 MINNESOTA RESIDENTIAL CODEROOF TRUSSESFASTENED TO PLATESw/ (4) 0.131"Ø x 3"TOENAILS & SIMPSONH2.5 CLIPNAIL BOTTOM PLATETO RIM/JOIST/BLOCKING w/ (3) 16dNAILS EVERY 16"NAIL BOTTOM PLATETO RIBBON BRACE /TRUSS w/ (3) 16dNAILS EVERY 16"NAIL EACH JOIST TOTOP PLATES w/ (3)0.131"Ø x 3" NAILS2x4 BLOCKINGBETWEENTRUSSES NAILEDTO TOP PLATESw/ (3) 0.131"Ø x 3"NAILS EACHNAIL EACH TRUSS TOTOP PLATES w/ (3)0.131"Ø x 3" TOENAILSROOF TRUSSFASTENED TOPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO RIM/JOIST/BLOCKINGw/ (3) 16d NAILSEVERY 16"NAIL RIM TOPPLATES w/0.131"Ø x 3"TOENAILS@ 6" O.C.NAIL BOTTOMPLATE TO LADDERTRUSS w/ (3) 16dNAILS EVERY 16"NAIL LADDERTRUSS TO TOPPLATES w/0.131"Ø x 3"NAILS @ 6" O.C.INTERIOR WALLPERPENDICULAR TO FRAMINGINTERIOR WALLPARALLEL w/ FRAMING2x4 BLOCKING BETWEENROOF TRUSSES NAILEDTO TOP PLATES w/ (3)0.131"Ø x 3" NAILS EACHNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN JOISTSNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH JOIST TO TOPPLATE w/ (3) 0.131"Ø x 3" NAILSNAIL BOTTOM PLATE TOBLOCKING w/ (3) 16dNAILS EVERY 16"PROVIDE FULL DEPTHBLOCKING BETWEEN TRUSSESNAILED TO TOP PLATES w/(3) 0.131"Ø x 3" NAILS EACHNAIL EACH TRUSS TO TOP PLATEw/ (3) 0.131"Ø x 3" TOENAILSPROVIDE ROOF TRUSSDIRECTLY IN LINE w/BRACED WALL PANELFASTENED TO PLATESw/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE JOIST DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.NAIL BOTTOM PLATETO BLOCKING w/ (3)16d NAILS EVERY 16"PROVIDE TRUSS DIRECTLYIN LINE w/ BRACED WALLPANEL FASTENED TOPLATES w/ 0.131"Ø x 3"TOENAILS @ 6" O.C.SCOPEDESIGN AND DETAIL OF THE MAIN WINDFORCE RESISTING SYSTEM FOR A SINGLE-FAMILY RESIDENCE. CONSTRUCTION ISTO BE IN ACCORDANCE WITH THIS DOCUMENT, STANDARD INDUSTRY PRACTICE, AND THE CODE.NOTES1.THESE DOCUMENTS APPLY TO STRUCTURAL ONLY. REFER TO CONSTRUCTION DOCUMENTS FOR MORE INFORMATION.2.ALL EXTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O., WHICHMEETS OR EXCEEDS THE REQUIREMENTS OF CODE SECTION R602.10.4-WSP AND CS-WSP.A.2x6 STUDS SPACED @ 16" O.C.B.EXTERIOR SHEATHING: 716" MIN. STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGESAND 12" O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.3.ALL INTERIOR WALLS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA, U.N.O.A.2x4 OR 2x6 STUDS SPACED @ 16" O.C.B.WALL SHEATHING: 12" MIN. GYPSUM SHEATHING FASTENED TO FRAMING w/ 5d COOLER NAILS @ 8" O.C. MAX. ORTYPE S/W WALLBOARD SCREWS @ 16" O.C. MAX. (58" MINIMUM STUD PENETRATION)4.ALL FLOORS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.FLOOR FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FLOOR SHEATHING: 34" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS.5.ALL ROOFS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING CRITERIA.A.ROOF FRAMING SPACED AT A MAXIMUM OF 24" O.C.B.FASTEN ALL ROOF FRAMING TO TOP PLATES WITH SIMPSON H2.5 CLIP OR EQUIVALENT AND (4) 0.131"Ø x 3"TOENAILS.C.ROOF SHEATHING: 12" STRUCTURAL PANEL SHEATHING w/ 8d COMMON NAILS @ 6" O.C AT PANEL EDGES AND 12"O.C. AT INTERMEDIATE SUPPORTS OR 134" 16 GAUGE STAPLES @ 3" / 6" SPACING.6.ALONG LENGTH OF WALLS, LAP WALL TOP PLATES A MINIMUM OF 24" AND FASTEN TOGETHER WITH (12) 0.131"Ø x 3" INLAP ZONE. AT CORNERS AND INTERSECTIONS, LAP PLATES AND PROVIDE (3) 0.131"Ø x 3" FACE NAILS.7.CONNECTIONS NOT SPECIFICALLY NOTED ARE TO BE IN ACCORDANCE WITH CODE TABLE R602.3(1).8.TALL WOOD WALL FRAMING IS TO BE DESIGNED BY SUPPLIER FOR GRAVITY AND OUT-OF-PLANE WIND LOADS.9.THE ENTRY PORCH IS CONSIDERED TO BE A PRIMARILY OPEN, NON-ESSENTIAL PORTION OF THE STRUCTURE AND ISEXCLUDED FROM THE OVERALL MAIN WINDFORCE SYSTEM OF THE HOME. PROVIDE CODE REQUIRED UPLIFTCONNECTIONS AT ALL POSTS AND TENSION CONNECTIONS AT LEDGERS.HARDWAREALTERNATETABLESIMPSONPRODUCTUSPPRODUCTA34MP34A35MPA1H2.5RT7HTT5HTT45LSTASTRAPSAMELTP4MP4FMSTCSTRAPSAMESTHD14/RJSTAD14/RJTITEN HDWEDGEBOLTHARDWARE IN SAMEROW MAY BE USEDINTERCHANGEABLYIN THIS DOCUMENTPlan Changes12-28-201ELEVATION D(3-FT)(3-FT)BRACEDWALL LINEPlan Changes6-14-212Extended Garage8-26-223(5-FT)(5-FT)BRACED WALL LINE 5 Ft Bumpout1-3-234WITH 5 FT BUMPOUTBRACEDWALL LINE2'-712"± Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-May-18 15:37:34Right-Suite® Universal 2022 22.0.01 RSU64702 Page 1 ...Documents\Wrightsoft HVAC\DRH- X304 - Elder.rup Calc = MJ8 Front Door faces: E Job:Load Short Form 5/18/22Date:Entire House By: Silver Tree Plumbing and Heating LLC 1335 Mendota Heights Rd, Mendota Heights, MN 55120 Phone: 651-319-4200 Email: andyf@silvertreepandh.com Web: www.silvertreepandh.com Project Information DRH- X304- ElderFor: Design Information InfiltrationClgHtg SimplifiedMethod88-15Outside db (°F)Semi-tightConstruction quality7270Inside db (°F) 1 (Semi-tight)Fireplaces1685Design TD (°F) M-Daily range 5030Inside humidity (%)5030Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade TradeModelCond AHRI ref Coil AHRI refEfficiency93 AFUE Efficiency 13 SEER Heating input Btuh0 Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm897 Actual air flow cfm897 Air flow factor cfm/Btuh0.017 Air flow factor cfm/Btuh0.055 Static pressure in H2O0 Static pressure in H2O0 Space thermostat Load sensible heat ratio 0.86 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room1 859 28804 7389 490 408 Room3 859 12715 4510 216 249 Room4 474 11219 4346 191 240 Entire House 2193 52738 16244 897 897 Other equip loads 1954 0 Equip. @ 0.93 RSM 15075Latent cooling 2715 TOTALS 2193 54692 17790 897 897 Date Certificate Posted X Passive (No Fan ) Active (With fan and monometer or other system monitoring device) Location (or future location) of Fan: Other Please Describe Here R-10 X R-10 X X R-20 X R-20 X R-20 X R-49 X R-49 X R-30 X R-30 X Not applicable, all ducts located in conditioned space R8 Not required per mech. code X Passive Powered Interlocked with exhaust device. Describe: Input in BTUS:60,000 Capacity in Gallons:Other, describe: AFUE or HSPF%92% Cfm's 5 " round duct OR " metal duct X Not required per mech. code Passive Low: Other, describe: X Low: Location of fan(s), describe: Cfm's " round duct OR " metal duct Output in Tons:2tankless Total ventilation (intermittent + continuous) rate in cfms: Balanced Ventilation capacity in cfms: High: High: MECHANICAL VENTILATION SYSTEM 119 59 Capacity continuous ventilation rate in cfms: REI60 BA13NA024 Model Heating System Nat Gas Bryant Interior Interior Location of duct or system: Heating or Cooling Ducts Outside Conditioned Spaces Electric Make-up Air Select a Type Rinnai Domestic Water Heater MECHANICAL SYSTEMS Rating or Size Efficiency 13SEER/EER 912SD36060E17 Manufacturer Bryant Nat GasTotal R-Value of all Types of InsulationType: Check All That Apply Mineral Fiberboard Insulation Location Foam, Closed Cell0.30 Describe other insulated areas Fiberglass, BlownFiberglass, Batts Foundation Wall R-value Average U-Factor (excludes skylights and one door) U: Duct system air tightness: Building envelope air tightness: Rim Joist (1st Floor) Mech Room Heat Recover Ventilator (HRV) Capacity in cfms: Energy Recover Ventilator (ERV) Capacity in cfms: 54,692 Heating Gain Cooling Load 59 119 Select Type Describe any additional or combined heating or cooling systems if installed: (e.g. two furnaces or air source heat pump with gas back-up furnace): Residential Load Calculation Heating Loss Combustion Air Select a Type Location of duct or system: 17,790 Per R401.3 Certificate. A building certificate shall be posted on or in the electrical distribution panel. New Construction Energy Code Compliance Certificate Name of Residential Contractor D.R. Horton MN License Number Lakeville17005 Draper Way BC605657 City Mailing Address of the Dwelling or Dwelling Unit THERMAL ENVELOPE Foam Open Cell Wall Below Entire Slab Rigid, Extruded Polystyrene Ceiling, flat Fuel Type Solar Heat Gain Coefficient (SHGC): Windows & Doors Ceiling, vaulted Bay Windows or cantilevered areas Floors over unconditioned area Rim Joist (2nd Floor+) 0.31 Appliances Rigid, Isocynurate Perimeter of Slab on Grade RADON CONTROL SYSTEM R10 ExteriorNon or Not Applicable Cooling System Builders Associaton of Minnesota version 101014 4 5 X 15 =752183 2183 X 0.02 =43.66 Continuous Ventilation Requirement = Enter # of Bedrooms Ventilation 118.66 59.33 Sq Ft of Home (including unfinished basements etc) Total Ventilation Requirement = Step 1: Draft Hood Fan Assisted 60000 Direct Vent Input:60000 Btu/hr & Power vent Draft Hood 0 Fan Assisted 160000 Direct Vent Input:160000 Btu/hr & Power vent Step 2: 571 ft^3 Step 3: Step 4:4a. Input:0 Btu/hr TRV:0 ft^3 4b. Input:0 Btu/hr RVFA:0 ft^3 Input:0 Btu/hr RVNFA:ft^3 TRV =0 +0 =0 ft^3 Ratio =571 /0 =#DIV/0! RF=1 -#DIV/0!= Input:0 Btu/hr CAOA=0 /3000 Btu/hr per in2 =0 in2 0 x #DIV/0!=#DIV/0!in2 CAOD =1.13 x #DIV/0!=#DIV/0!in Required Volume Fan Assisted (RVFA) Complete vented combustion appliance information: Calculate the volume of the Combustion Appliance Space (CAS) containing combustion appliances. IFGC Appendix E, Worksheet E-1 Residential Combustion Air Calculation Method (for Furnace, Boiler, and/or Water Heater in the Same Space) 1346.6012 IFGC APPENDIX E, WORKSHEET E-1. Total Btu/hr input of all non-fan-assisted appliances If CAS Volume (from Step 2) is less than TRV then go to STEP 5. Known Air Infiltration Rate (KAIR) MethodTotal Btu/hr input of all fan-assisted and power vent appliances (DO NOT COUNT DIRECT VENT APPLIANCES) Use Fan-Assisted Appliances column in Table E-1 to find Total Btu/hr input of all combustion appliances (DO NOT COUNT DIRECT VENT APPLIANCES) The CAS includes all spaces connected to one another by code compliant openings.CAS Volume: Furnace/Boiler: Water Heater:(Not fan assisted) (Not fan Assisted) Total Required Volume (TRV) = RVFA + RVNFA Required Volume Non-Fan-Assisted (RVNFA) If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. Ratio = CAS Volume (from Step 2) divided by TRV (from Step 4a or Step 4b) Determine air Changes per Hour (ACH)1Default ACH values have been incorporated into Table E-1 for use with Method 4b (KAIR Method). If the year of construction or ACH is not known, use method 4a (Standard Method) Use Standard Method column in Table E-1 to find Total Required Volume (TRV) If CAS Volume (from Step 2) is greater than TRV then no outdoor openings are needed. Determine Required Volume for Combustion Air.Standard Method #DIV/0! Step 7: Calculate single outdoor opening as if all combustion air is from outside. Total Btu/hr input of all Combustion Appliances in the same CAS (EXCEPT DIRECT VENT) Total Btu/hr divided by 3000 Btu/hr per in^2 Use Non-Fan-Assisted Appliances column in Table E-1 to find Combustion Air Opening Area (CAOA): Step 5: Calculate the ratio of available interior volume to the total required volume. Step 6: Calculate Reduction Factor (RF). RF = 1 minus Ratio If CAS Volume (from Step 2) is less than TRV then go to STEP 5. CAOD = 1.13 multiplied by the square root of Minimum CAOA 1If desired, ACH can be determined using ASHRAE calculation or blower door test. Follow procedures in Section 304. Step 8: Calculate Minimum CAOA. Minimum CAOA = CAOA multiplied by RF Minimum CAOA = Step 9: Calculate Combustion Air Opening Diameter (CAOD) 1994(1) to Present Pre 1994(2)1994(1) to Present Pre 1994(2) 5,000 250 375 188 525 263 10,000 500 750 375 1,050 525 15,000 750 1,125 563 1,575 788 20,000 1,000 1,500 750 2,100 1,05025,000 1,250 1,875 938 2,625 1,31330,000 1,500 2,250 1,125 3,150 1,57535,000 1,750 2,625 1,313 3,675 1,83840,000 2,000 3,000 1,500 4,200 2,10045,000 2,250 3,375 1,688 4,725 2,363 50,000 2,500 3,750 1,875 5,250 2,625 55,000 2,750 4,125 2,063 5,775 2,888 60,000 3,000 4,500 2,250 6,300 3,15065,000 3,250 4,875 2,438 6,825 3,41370,000 3,500 5,250 2,625 7,350 3,67575,000 3,750 5,625 2,813 7,875 3,93880,000 4,000 6,000 3,000 8,400 4,20085,000 4,250 6,375 3,188 8,925 4,463 90,000 4,500 6,750 3,375 9,450 4,725 95,000 4,750 7,125 3,563 9,975 4,988 100,000 5,000 7,500 3,750 10,500 5,250105,000 5,250 7,875 3,938 11,025 5,513110,000 5,500 8,250 4,125 11,550 5,775115,000 5,750 8,625 4,313 12,075 6,038120,000 6,000 9,000 4,500 12,600 6,300125,000 6,250 9,375 4,688 13,125 6,563 130,000 6,500 9,750 4,875 13,650 6,825 135,000 6,750 10,125 5,063 14,175 7,088 140,000 7,000 10,500 5,250 14,700 7,350 145,000 7,250 10,875 5,438 15,225 7,613150,000 7,500 11,250 5,625 15,750 7,875155,000 7,750 11,625 5,813 16,275 8,138160,000 8,000 12,000 6,000 16,800 8,400165,000 8,250 12,375 6,188 17,325 8,663170,000 8,500 12,750 6,375 17,850 8,925 175,000 8,750 13,125 6,563 18,375 9,188 180,000 9,000 13,500 6,750 18,900 9,450 185,000 9,250 13,875 6,938 19,425 9,713190,000 9,500 14,250 7,125 19,950 9,975195,000 9,750 14,625 7,313 20,475 10,238200,000 10,000 15,000 7,500 21,000 10,500205,000 10,250 15,375 7,688 21,525 10,763210,000 10,500 15,750 7,875 22,050 11,025 215,000 10,750 16,125 8,063 22,575 11,288 220,000 11,000 16,500 8,250 23,100 11,550 225,000 11,250 16,857 8,438 23,625 11,813230,000 11,500 17,250 8,625 24,150 12,075(1)The 1994 date refers to dwellings constructed under the 1994 Minnesota Energy Code. The default KAIR used in this section of the table is 0.20 ACH.(2)This section of the table is to be used for dwellings constructed prior to 1994. The default KAIR used in this section of the table is 0.40 ACH. 1346.6014 IFGC APPENDIX E, TABLE E-1. Known Air Infiltration Rate (KAIR) Method (ft3) Fan Assisted Non-Fan-Assisted IFGC Appendix E, Table E-1 Residential Combustion Air Required Volume (Required Interior Volume Based on Input Rating of Appliances) Standard Method (ft3) Input Rating (Btu/hr) One or multiple power vent or direct vent appliances or no combustion appliancesA One or multiple fan-assisted appliances and power vent or direct vent appliancesB One atmospherically vented gas or oil appliance or one solid fuel applianceC Multiple atmospherically vented gas or oil appliances or solid fuel appliancesD 1a) pressure factor (cfm/sf) 0.15 0.09 0.06 0.03 b) conditioned floor area (sf) (including unfinished basements) 2183 0 0Estimated House Infiltration (cfm): [1a x 1b] 327.45 0 0 0 2.a) Exhaust Capacity continuous exhaust-only ventilation systems (cfm): (not applicable to balanced ventilation systems such as HRV) 0 0 0 0 b) clothes dryer 135 135 135 135 c) 80% of largest exhaust rating (cfm): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) 240 0 0 0 d) 80% of next largest exhaust rating (cfm): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) 0 0 0 Total Exhaust Capacity (cfm): [2a+2b+2c+2d] 375 135 135 135 3.a) Makeup Air Requirement Total Exhaust Capacity (from above) 375 135 135 135 b) Estimated House Infiltration (from above) 327.45 0 0 0 Makeup Air Quantity (cfm): [3a – 3b] (if value is negative, no makeup air is needed) 47.55 135 135 135 4. For Makeup Air Opening Sizing, refer to Table 501.3.2 One or multiple power vent or direct vent appliances or no combustion appliancesA One or multiple fan-assisted appliances and power vent or direct vent appliancesB One atmospherically vented gas or oil appliance or one solid fuel applianceC Multiple atmospherically vented gas or oil appliances or solid fuel appliancesD Passive makeup air opening duct diameterE,F,G Type of opening or system (cfm) (cfm) (cfm) (cfm) (inches) Passive Opening 1-36 1-22 1-15 1-9 3Passive Opening 37-66 23-41 16-28 10-17 4 Passive Opening 67-109 42-66 29-46 18-28 5Passive Opening 110-163 67-100 47-69 29-42 6Passive Opening 164-232 101-143 70-99 43-61 7Passive Opening 233-317 144-195 100-135 62-83 8Passive Opening with Motorized Damper 318-419 196-258 136-179 84-110 9Passive Opening with Motorized Damper 420-539 259-332 180-230 111-142 10Passive Opening with Motorized Damper 540-679 333-419 231-290 143-179 11Powered Makeup AirH >679 >419 >290 >179 not applicable D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. A Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustionappliances. B Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. Table 501.3.1 Procedure to Determine Makeup Air Quantity for Exhaust Equipment in Dwellings Use the Appropriate Column to Estimate House Infiltration A Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliances or if there are no combustion appliances. B Use this column if there is one fan-assisted appliance per venting system. Other than atmospherically vented appliances may also be included. C Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. G Barometric dampers are prohibited in passive makeup air openings when any atmospherically vented appliance is installed.H Powered makeup air shall be electrically interlocked with the largest exhaust system. Table 501.3.2 Makeup Air Opening Sizing Table for New and Existing Dwellings C Use this column if there is one atmospherically vented (other than fan-assisted) gas or oil appliance per venting system or one solid fuel appliance. D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmosphericallyvented gas or oil appliances and solid fuel appliance(s). E An equivalent length of 100 feet of round smooth metal duct is assumed. Subtract 40 feet for the exterior hood and ten feet for each 90-degree elbow to determine the remaining length of straight duct allowable. F If flexible duct is used, increase the duct diameter by one inch. Flexible duct shall be stretched with minimal sags. NEW RESIDENTIAL CONSTRUCTION SWPPP VERIFICATION This form must be completed and submitted with all new residential permit applications. New residential building permits WILL NOT be issued without this completed form. Project Site Address: _____________________________________________________________________ Company Name: _________________________________________________________________________ Primary Contact: _________________________________________________________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Description of Land Disturbing Activity: _____________________________________________________ NPDES Construction Stormwater Permit # C000 ___ ___ ___ ___ ___ or # SUB00 ___ ___ ___ ___ ___ If you are not covered under a NPDES Construction Stormwater Permit administered by the MPCA, an erosion and sediment control plan MUST be submitted with the residential building permit application. “The permittee(s) shall ensure that the individuals are trained by local, state, federal agencies, professional organizations or other entities in erosion prevention, sediment control, permanent Stormwater management and the Minnesota NPDES/SDS Construction Stormwater Permit.” (NPDES Construction Stormwater Permit, MPCA) “The permittee(s) must ensure that a trained person (as identified in Part III.A.3.a) will routinely inspect the entire construction site at least once every seven (7) days during active construction and within 24 hours after a rainfall event greater than 0.5 inches in 24 hours.” (NPDES Construction Stormwater Permit, MPCA) Contact information of person CERTIFIED to provide weekly onsite erosion and sediment control inspections and corrective actions: Name of Person: ________________________________Company: _______________________________ Phone # (24 hr Contact): ______________________ Email: ______________________________________ Entity that Provided Training: ________________________ Certification Expiration Date: ____________ NOTE: Prior to any land-disturbing activity, all erosion and sediment controls must be installed on the project site and on individual lots. No land disturbing activity may begin until a residential building permit has been issued. I understand, the above information to be true and I will have read, understood, and accepted all terms and conditions of the National Pollutant Discharge Elimination System (NPDES) Permit (MN R 100001). The City of Lakeville may issue a STOP WORK ORDER; withhold building inspections; or, draw on securities/escrows to bring the site into compliance with the NPDES Construction Stormwater Permit (MN R 100001) or erosion and sediment control plan. Signature: ________________________________________________ Date:_________________________ Contact the City of Lakeville with questions at erosion@lakevillemn.gov or 952-985-4500 Ryan Klika 8/20/24 X PM