HomeMy WebLinkAboutLA24-00538 - APPROVED-Gaul CADSATELLITE MAPCOVER PAGEPV-00EQUIPMENT DATASHEETS ATTACHEDEQUIPMENT SPECIFICATIONSENLARGED VIEWELECTRICAL DIAGRAMWARNING LABELSATTACHMENT PLAN & DETAILSSHEET INDEXPV-02PV-03PV-04PV-06PV-05VICINITY MAPSITE PLANPV-01DIRECTORY PLACARDPV-05.1FRAMING DETAILPV-03.1SITE NOTES2.1.1 A LADDER WILL BE IN PLACE FOR INSPECTION INACCORDANCE WITH OSHA REGULATIONS.2.1.2 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLEAND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NOSTORAGE BATTERIES.2.1.3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANYPLUMBING, MECHANICAL, OR BUILDING ROOF VENTS.2.1.4 PROPER ACCESS AND WORKING CLEARANCE AROUNDEXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BEPROVIDED IN ACCORDANCE WITH SECTION NEC 110.26.2.1.5 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, ANDMAINTAINED IN ACCORDANCE WITH THIS CODE AND THEAPPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THEROOF COVERING SERVES TO PROTECT THE BUILDING ORSTRUCTURE.EQUIPMENT LOCATIONS2.2.1 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS INACCORDANCE WITH NEC 110.26.2.2.2 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BERATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIEDBY NEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15(B)(3)(C).2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDERPV MODULES IN ACCORDANCE WITH NEC 690.34.2.2.4 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDEDWHERE THE INVERTER IS NOT WITHIN SIGHT OF THE ACSERVICING DISCONNECT. 2.2.5 ALL EQUIPMENT SHALL BEINSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL INACCORDANCE WITH NEC APPLICABLE CODES.2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE ANDRATED FOR OUTDOOR USAGE WHEN APPROPRIATE.STRUCTURAL NOTES2.3.1 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED INACCORDANCE WITH THE CODE-COMPLIANT INSTALLATIONMANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEENMODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCEBEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, INACCORDANCE WITH RAIL MANUFACTURER’S INSTALLATIONPRACTICES.2.3.2 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'SSPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BEFLASHED & SEALED PER LOCAL REQUIREMENTS.STRUCTURAL NOTES (CONT.)2.3.3 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETEDAND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSEDCONTRACTOR.2.3.4 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATERTHAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTUREROR PROFESSIONAL ENGINEERING GUIDANCE.2.3.5 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BESTAGGERED AMONGST THE ROOF FRAMING MEMBERS.WIRING & CONDUIT NOTES2.4.1 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIRPURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUMCODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING.2.4.2 CONDUCTORS SIZED IN ACCORDANCE WITH THE NEC2.4.3 AC CONDUCTORS TO BE COLORED OR MARKED PER NEC2.4.4 LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USED INACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING ORLABELING PER NECGROUNDING NOTES2.5.1 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIRPURPOSE, AND GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALLBE RATED FOR SUCH USE.2.5.2 PV EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH NEC690.43 AND NEC TABLE 250.122.2.5.3 METAL PARTS OF MODULE FRAMES, MODULE RACKING, ANDENCLOSURES CONSIDERED GROUNDED IN ACCORDANCE WITH NEC250.134 AND 250.136(A).2.5.4 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED INACCORDANCE WITH NEC 690.45 AND INVERTER MANUFACTURER'SINSTALLATION PRACTICES2.5.5 EACH MODULE WILL BE GROUNDED AS SHOWN IN MANUFACTURERDOCUMENTATION AND APPROVED BY THE AHJ. 2.5.6 THE GROUNDINGCONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THEREMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDINGCONDUCTOR TO ANOTHER MODULE.2.5.7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BECOLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER PER NEC250.1192.5.8 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED INACCORDANCE WITH NEC 250, NEC 690.47 AND THE AHJ.2.5.9 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1)AND (2) TO REDUCE FIRE HAZARDSDISCONNECTION AND OVERCURRENT PROTECTION NOTES2.6.1 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THATWHEN THE SWITCH IS OPENED THE CONDUCTORS REMAININGENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINESIDE” (TYPICALLY THE UPPER TERMINALS).2.6.2 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITYPERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH2.6.3 PV SYSTEM CIRCUITS INSTALLED ON OR IN HABITABLEBUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TOREDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS INACCORDANCE WITH 690.122.6.4 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC690.8, 690.9, AND 240.2.6.5 INVERTER ON-GRID BRANCHES SHALL BE CONNECTED TO ASINGLE BREAKER OR GROUPED FUSE DISCONNECT(S) INACCORDANCE WITH NEC 110.3(B).2.6.6 IF REQUIRED BY THE AHJ, SYSTEM WILL INCLUDE ARC-FAULTCIRCUIT PROTECTION IN ACCORDANCE WITH NEC 690.11 ANDUL1699B.INTERCONNECTION NOTES2.7.1 LOAD SIDE INTERCONNECTION SHALL BE IN ACCORDANCEWITH NEC 705.12 (B).2.7.2 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUSOUTPUT MAY NOT EXCEED 120 PERCENT OF BUSBAR RATING PERNEC 705.12 (B).2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUTCIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICEPROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OFTHE AMPACITY OF THE BUSBAR, PV DEDICATED BACKFEEDBREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROMTHE UTILITY SOURCE OCPD IN ACCORDANCE WITH NEC 705.12 (B).2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINERPANEL, TOTAL RATING OF ALL OVERCURRENT PROTECTION DEVICESSHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE MAINOVERCURRENT PROTECTION DEVICE MAY BE EXCLUDED INACCORDANCE WITH NEC 705.12 (B).2.7.5 FEEDER TAP INTERCONNECTION (LOAD SIDE) IN ACCORDANCEWITH NEC 705.12 (B).2.7.6 SUPPLY SIDE TAP INTERCONNECTION IN ACCORDANCE WITHTO NEC 705.11 WITH SERVICE ENTRANCE CONDUCTORS INACCORDANCE WITH NEC 230.42.2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCESOUTPUT IS EXEMPT FROM ADDITIONAL FASTENING PER NEC 705.12(B).GENERAL NOTESPHONE - (541) 816-4047LIC. NO. - 226333CONTRACTOR3521 AVION DRIVE, SUITE #200,MEDFORD, OREGON 97504PURELIGHT POWER NEWCO LLCPV-009/3/2024SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERREVDATEDESCRIPTIONREVISIONSPROJECT NAMESTRUCTURAL STAMPAHJ STAMPAPN #: 221674005020AHJ: CITY OF LAKEVILLEUTILITY: XCEL ENERGYJENNIFER GAUL20890 GOODHUE WAY,LAKEVILLE, MN 550445075812434JALENDE5@YAHOO.COMSYSTEM SIZE: DC SIZE: 13.940 KW DC-(STC)AC SIZE: 9.500 KW ACNEW PV SYSTEM SPECIFICATIONSNEW PHOTOVOLTAIC ROOF MOUNTED SYSTEM13.940 KW DC/9.500 KW AC20890 GOODHUE WAY, LAKEVILLE, MN 55044DESIGN CRITERIA1. ROOF PITCH:27°, 27°2. AZIMUTH:270°, 90°3. MODULE:(34) YUKON SERIES SEG-410-BMD-HV4. INVERTER:(01) TESLA 5.7 KW INVERTER [240V](01) TESLA 3.8 KW INVERTER [240V]5. RSD:(14) TESLA MCI-2 RSD6. NOMINAL AMPERAGE: 40.007. ROOF AREA:2727 FT²8. PV ARRAY AREA: 714.77 FT²9. PV ARRAY WEIGHT: 1611.26 LBS10. ROOF SURFACE TYPE: COMPOSITE SHINGLE11. ROOF STRUCTURE: 2"X4" TRUSS @ 24" OC12. BUILDING STORY: ONE STORY13. SNOW LOAD:50 PSF14. WIND SPEED:110 MPH15. WIND EXPOSURE: B16. RISK CATEGORY: IICOVER PAGESCOPE OF WORK1.2.1 CONTRACTOR IS RESPONSIBLE FOR THE DESIGN ANDSPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM.THE CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTION OFEXISTING ONSITE CONDITIONS TO DESIGN, SPECIFY, ANDINSTALL THE ROOF-MOUNTED PHOTOVOLTAIC SYSTEMDETAILED IN THIS DOCUMENTAPPLICABLE CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODES:2020 MINNESOTA STATE BUILDING CODE2020 MINNESOTA STATE RESIDENTIAL CODE2020 MINNESOTA STATE FIRE CODE2023 NATIONAL ELECTRICAL CODEAS ADOPTED BY CITY OF LAKEVILLEPROJECT NOTES1.1.1 THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THERELEVANT YEAR OF THE NATIONAL ELECTRIC CODE (NEC), ALLMANUFACTURER’S LISTING AND INSTALLATION INSTRUCTIONS, AND THERELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVINGJURISDICTION’S (AHJ) APPLICABLE CODES.1.1.2 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVEDAND THE PV SYSTEM MUST BE INSPECTED PRIOR TO OPERATION1.1.3 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVEINVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED ANDLISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC ANDOTHER GOVERNING CODES1.1.4 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDINGCODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALLPLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NECAND AHJ.Trevor JonesProfessional Engineer I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota. Signature: Typed or Printed Name: Date: License Number: 6210109/04/2024Concept Approval ONLYSubject to Field InspectionInspectorDate2015MN BldgCode10/09/2024jnuetzman
DRIVEWAYGOODHUE WAY66'-5"134'-11"66'-5"134'-11"8'-1"34'-7"11'-10"40'-11"NSITE PLANSCALE:1"=15'-0"- PROPERTY LINE- FENCE LINELEGENDSITE PLANPV-011PV-019/3/2024SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERREVDATEDESCRIPTIONREVISIONSPROJECT NAMESTRUCTURAL STAMPAHJ STAMPAPN #: 221674005020AHJ: CITY OF LAKEVILLEUTILITY: XCEL ENERGYJENNIFER GAUL20890 GOODHUE WAY,LAKEVILLE, MN 550445075812434JALENDE5@YAHOO.COMNOTE:1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY!2. ALL TESTING SHALL BE PERFORMED BY QUALIFIEDPERSONNEL, WITH PROPER PERSONAL PROTECTIVEEQUIPMENT3. THE PRODUCTION METER AND AC DISCONNECT SHOULDBE LOCATED TOGETHER IN A READILY ACCESSIBLELOCATION WITHIN 10' OF THE MAIN SERVICE METER4. 24/7 UNESCORTED KEYLESS ACCESS SHALL BEPROVIDED FOR THE METERS AND AC DISCONNECTUTILITY AC DISCONNECT SHOULD BELOCATED WITHIN 10 FEET OF THE MAINSERVICE METER(E) WOODEN DECK(E) HOUSEROOF ACCESS POINT(E) GARAGEFRONT OFHOUSE
Trevor JonesProfessional Engineer I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota. Signature: Typed or Printed Name: Date: License Number: 6210109/04/2024
ROOF 1ROOF 2N
MIN. 6"MIN. 6"MIN. 6"MIN. 6"MIN. 6"MIN. 6"PV-029/3/2024SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERREVDATEDESCRIPTIONREVISIONSPROJECT NAMESTRUCTURAL STAMPAHJ STAMPAPN #: 221674005020AHJ: CITY OF LAKEVILLEUTILITY: XCEL ENERGYJENNIFER GAUL20890 GOODHUE WAY,LAKEVILLE, MN 550445075812434JALENDE5@YAHOO.COMENLARGED VIEWSCALE:1"=10'-0"ENLARGED VIEWPV-021= FLUE / PLUMBING VENT= MECHANICAL VENTNOTES:1. ROOF ACCESS POINT SHALL NOT BE LOCATED INAREAS THAT REQUIRE THE PLACEMENT OF GROUNDLADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OFBUILDING CONSTRUCTION IN LOCATIONS WHERE THEACCESS POINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES ORSIGNS.2. STRUCTURES, PATIO COVERS, AND/OR ADDITIONSBUILT WITHOUT PERMITS TO BE RESOLVED BY ASEPARATE PERMIT.LEGENDFIRE SETBACKS36"
18"= STRING 1= STRING 2= STRING 3= TESLA MCI-2 RSD (1 PER 3 MODULES)SLOPE - 27°AZIMUTH - 90°MODULE QTY - 20TRUSS - 2"X4" @ 24" O.C.SURFACE TYPE - COMPOSITE SHINGLEROOF 2SLOPE - 27°AZIMUTH - 270°MODULE QTY - 14TRUSS - 2"X4" @ 24" O.C.SURFACE TYPE - COMPOSITE SHINGLEROOF 1SCALE:N.T.SEQUIP. ELEVATIONPV-022= STRING 4PLAN VIEW TOTAL ROOF AREA: 2727 FT²TOTAL PV ARRAY AREA:714.77 FT²TOTAL % OF ROOF COVERED BY PV: 26.21%GRADEACDUMPMINVACD MSP(E) UTILITY METER(UNDERGROUND SERVICE)METER #: 358 823 160(N) UTILITY OWNED PVPRODUCTION METER, 120/240V(E) MAIN SERVICE PANEL(N) TESLA 5.7 KW INVERTER [240V](N) UTILITY AC DISCONNECTVISIBLE-OPEN TYPE, LOCKABLE &READILY ACCESSIBLE, LABELED60A NON-FUSED AC DISCONNECT(SQUARE D DU222RB)(N) AC DISCONNECT VISIBLE-OPENTYPE, LOCKABLE & READILYACCESSIBLE, LABELED 60A FUSEDAC DISCONNECT(SQUARE D D222NRB)FRONT OF HOUSE
BACK OF HOUSE
GOODHUE WAY(NEAREST CROSS STREETGREENWOOD AVE (50' APPX))ROOF ACCESSPOINTJB(N) JUNCTIONBOX, NEMA 3R(E)UTILITY METER(N)AC DISCONNECT(N) UTILITY AC DISCONNECT(N) TESLAINVERTER(S)(N) UTILITYOWNED PVPRODUCTIONMETERUTILITY AC DISCONNECT SHOULDBE LOCATED WITHIN 10 FEET OFTHE MAIN SERVICE METERNOTE:1. AC DISCONNECT TO BE VISIBLE, LOCKABLEAND LABELED.2. UTILITY HAS 24/7 UNESCORTED KEYLESSACCESS TO ALL METERS AND DISCONNECTS.44.65"67.80"STRING COUNT (INV#1):STRING #1 - 10 MODULESSTRING #2 - 10 MODULESINVCB(N) AC COMBINER PANEL(N) TESLA 3.8 KW INVERTER [240V](N) COMBINERPANELSTRING COUNT INV#2:STRING #3 - 07 MODULESSTRING #4 - 07 MODULESTrevor JonesProfessional Engineer I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota. Signature: Typed or Printed Name: Date: License Number: 6210109/04/2024
ATTACHMENT PLAN& DETAILS- ATTACHMENT POINTS- RAIL- STRUCTURAL MEMBERLEGENDTYPICAL ATTACHMENT PLAN (PORTRAIT)SCALE: NTSPV-031.0TYPICAL ATTACHMENT PLAN (LANDSCAPE)SCALE: NTSPV-031.1STRUCTURAL MEMBER @ 24" OC4'-0" OC ATTACHMENT SPACINGSTRUCTURAL MEMBER @ 24" OC4'-0" OC ATTACHMENT SPACINGDISTRIBUTED LOAD CALCULATIONSMODULEYUKON SERIES SEG-410-BMD-HVMODULE WEIGHT47.39 LBSMODULE DIMENSIONS (L" x W")67.80" x 44.65"TOTAL QTY. OF MODULES34TOTAL WEIGHT OF MODULES 1611.26 LBSTYPE OF RACKINGSUNMODO SMR300 RAILTYPE OF ATTACHMENTSUNMODO NANOMOUNTDISTRIBUTED WEIGHT OF RACKING 0.5 PSFTOTAL WEIGHT OF ARRAY1968.65 LBSAREA OF MODULE21.02 SQFT.TOTAL ARRAY AREA714.77 SQFT.DISTRIBUTED LOAD2.75 PSFPV-039/3/2024SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERREVDATEDESCRIPTIONREVISIONSPROJECT NAMESTRUCTURAL STAMPAHJ STAMPAPN #: 221674005020AHJ: CITY OF LAKEVILLEUTILITY: XCEL ENERGYJENNIFER GAUL20890 GOODHUE WAY,LAKEVILLE, MN 550445075812434JALENDE5@YAHOO.COMNOTE: 6" MAXIMUM DISTANCE FROM ROOF SURFACE TO TOP OF PV MODULESSEE ENLARGED VIEWHEX LAG BOLT M8X110, DIN571, 304S W/ SEALINGWASHER .33 ID X .75 X .157INTO STRUCTURAL MEMBERSUNMODO NANOMOUNTSUNMODO RAILSUNMODO END / MID CLAMPL-FOOT ADAPTOR(E) STRUCTURAL MEMBERPV MODULEPV MODULE(E) STRUCTURAL MEMBERCOMP SHINGLEScale: NTSATTACHMENT DETAILPV-032Scale: NTSENLARGED VIEWPV-033(SMR 300)Trevor JonesProfessional Engineer I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota. Signature: Typed or Printed Name: Date: License Number: 6210109/04/2024
PV-03.19/3/2024SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERREVDATEDESCRIPTIONREVISIONSPROJECT NAMESTRUCTURAL STAMPAHJ STAMPAPN #: 221674005020AHJ: CITY OF LAKEVILLEUTILITY: XCEL ENERGYJENNIFER GAUL20890 GOODHUE WAY,LAKEVILLE, MN 550445075812434JALENDE5@YAHOO.COMFRAMING DETAILSCALE: NTSFRAMING DETAILPV-03.11SLOPE - 27°AZIMUTH - 90°MODULE QTY - 20TRUSS - 2"X4" @ 24" O.C.SURFACE TYPE - COMPOSITE SHINGLEROOF 2SLOPE - 27°AZIMUTH - 270°MODULE QTY - 14TRUSS - 2"X4" @ 24" O.C.SURFACE TYPE - COMPOSITE SHINGLEROOF 15.18"25'-0"1'-0"PV MODULESROOF #12"X4" TRUSS@ 24" O.C.11'-6"27°1'
-6
"17'-0"5.18"25'-0"1'-0"PV MODULESROOF #22"X4" TRUSS@ 24" O.C.11'-6"27°17'-11"2'-9"LOAD BEARINGWALLLOAD BEARINGWALLTrevor JonesProfessional Engineer I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota. Signature: Typed or Printed Name: Date: License Number: 6210109/04/2024
4MLINELOADL1L1L2L2GL1L2NGL1L2N(N) PV PRODUCTIONMETER, UTILITY OWNED, NEMA 3R, UL LISTED200A RATED, 1-PHASE,3-WIRE, 120/240VGL1L2N5(3) #6 AWG6(1) #6 AWG EGCBONDED(N) AC DISCONNECTVISIBLE-OPEN TYPE,LOCKABLE & READILYACCESIBLE, LABELED60A FUSED DISCONNECTW/(2) 50A FUSES, 240V, NEMA3R, UL LISTED(SQUARE D D222NRB)(N) UTILITY AC DISCONNECT VISIBLE-OPEN TYPE,LOCKABLE & READILYACCESIBLE, LABELED60A NON-FUSIBLE, 240V,NEMA 3R, UL LISTED(SQUARE D DU222RB)(3) #8 AWG(1) #10 EGC(3) #8 AWG(1) #10 EGC(3) #8 AWG(1) #10 EGC(E) 225A MAIN SERVICE PANEL, 240V(E) 200A/2P MAINBREAKER, 240VSUPPLY SIDECONNECTION(NEC 705.11)L2 NL2L1TO UTILITY GRID(E) BI-DIRECTIONALUTILITY METER1-PHASE, 3-W,120V/240VMLINELOADGEXISTING GROUNDINGELECTRODE SYSTEMGECNSUPPLY SIDE TAPCONNECTION USINGNON-SPLICING LUGSMETER #: 358 823 160(N) MIDNITE SOLARMNSPD-600 SURGEPROTECTION DEVICEGNL2L1N(N) 125A DEDICATEDPV COMBINERPANEL, 240VG30A20AMETAL CONDUIT REQUIRED FOR DC CONDUCTORSTHAT ARE RAN INTERIOR OF BUILDING(N) JUNCTION BOX600 V, NEMA 3RUL LISTED(4) #12 AWG PV WIRE(1) #6 AWG BARE CU(4) #12 AWG(1) #12 EGC- +- +1109109- + - +2- +- +1- + - +2YUKON SERIES SEG-410-BMD-HV- +3- +388- +- +TESLA SOLAR SHUTDOWN DEVICE,1 FOR EVERY 3 MODULESACDC(N) TESLA 5.7 KW INVERTER[240V] (INV#1)OUTPUT: 240 VAC, 24ANEMA 3R, UL LISTED12METAL CONDUIT REQUIRED FOR DC CONDUCTORSTHAT ARE RAN INTERIOR OF BUILDING(N) JUNCTION BOX600 V, NEMA 3RUL LISTED- +- +1076- + - +2- +- +1- + - +2YUKON SERIES SEG-410-BMD-HV- +3- +35- +- +TESLA SOLAR SHUTDOWN DEVICE,1 FOR EVERY 3 MODULESACDC(N) TESLA 3.8 KW INVERTER[240V] (INV#2)OUTPUT: 240 VAC, 16ANEMA 3R, UL LISTED120765(4) #12 AWG PV WIRE(1) #6 AWG BARE CU(4) #12 AWG(1) #12 EGC3(3) #10 AWG(1) #10 EGC3A(3) #12 AWG(1) #12 EGC44ELECTRICALDIAGRAMPV-049/3/2024SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERREVDATEDESCRIPTIONREVISIONSPROJECT NAMESTRUCTURAL STAMPAHJ STAMPAPN #: 221674005020AHJ: CITY OF LAKEVILLEUTILITY: XCEL ENERGYJENNIFER GAUL20890 GOODHUE WAY,LAKEVILLE, MN 550445075812434JALENDE5@YAHOO.COMDESCRIPTIONFORMULARESULTPV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25 = ((01 x 24) + (01 x 16))A x 1.2550.00A (SELECTED OCPD = 50A)DC WIRE CACLULATIONWIRE IDEXPECTEDWIRE TEMP(°C)TEMPDERATE(90 °C)QTY OF CURRENTCARRYINGCONDUCTORSCONDUITFILL DERATEMINIMUMCONDUIT SIZE(TBD ON SITE)WIRE GAUGE &TYPECONDUCTORAMPACITY @90°C (A)CONDUCTORAMPACITY @75°C (A)REQUIRED CIRCUITCONDUCTORAMPACITY (A)ADJUSTEDCONDUCTORAMPACITY @ 90 °C (A)NEUTRALCONDUCTORSIZE & TYPEGROUND WIRESIZE & TYPE1310.964IN AIRN/A#12 AWG PV WIRE 302521.5628.80NONE#6 AWG BARE Cu2310.9640.83/4"#12 THWN-2302521.5623.04NONE #12 THWN-2AC WIRE CACLULATION3310.96313/4"#10 THWN-2403530.0038.40#10 THWN-2 #10 THWN-23A310.96313/4"#12 THWN-2302520.0028.80#12 THWN-2 #12 THWN-24310.96313/4"#8 THWN-2555050.0052.80#8 THWN-2#10 THWN-25310.96313/4"#6 THWN-2756550.0072.00#6 THWN-2 NONE6NONE#6 THWN-2NOTE:1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY!2.ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNEL, WITH PROPER PERSONALPROTECTIVE EQUIPMENT3. THE PRODUCTION METER AND AC DISCONNECT SHOULD BE LOCATED TOGETHER IN AREADILY ACCESSIBLE LOCATION WITHIN 10' OF THE MAIN SERVICE METER4. 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL XCEL ENERGYEQUIPMENT5. NOTE ALL THE APPLICABLE NEC CODES6.SHOW ALL THE SYSTEMS INCLUDING STORAGE, EXISTING AND NEW (IF APPLICABLE)7. SERVICES <320A WILL USE SELF-CONTAINED MAIN SERVICE METERS. 320A SERVICES MUSTINDICATE WHETHER THE METERING WILL BE SELF-CONTAINED OR TRANSFORMER METERED.ALL SERVICES 400A OR GREATER MUST BE TRANSFORMER METERED8. PRODUCTION METER LOCATED WITHIN 10 FT OF METER9.WIRES LOCATED IN READILY ACCESSIBLE LOCATIONS SHALL BE GUARDED PER NEC690.31(A)10. CONDUIT TO BE UL LISTED FOR WET LOCATIONS AND UV PROTECTED (EX. -EMT,PVC ORRMC) *FMC MAY BE USED IN INDOOR APPLICATIONS WHERE PERMITTED BY NEC ART. 34811. VISIBLE LOCKABLE AND LABELED DISCONNECT IS LOCATED WITHIN 10FT OF METER12.THE INVERTERS ARE UL1741 CERTIFIEDPOC/RPAMINIMUM WIRE SIZES CALLED OUT.USE OF LARGER WIRE ISACCEPTABLE.7/8" MINIMUM CONDUIT HEIGHTABOVE ROOF SURFACELABEL #7 TO BE EVERY 10' ON CONDUIT GOING TO J-BOX ON DCSTRINGS (EXPOSED RACEWAY, COVERS OR ENCLOSURES OF PULLBOXES AND JUNCTION BOXES, CONDUIT BODIES IN WHICH ANYAVAILABLE CONDUIT OPENINGS ARE UNUSEDUTILITY AC DISCONNECT SHOULD BELOCATED WITHIN 10 FEET OF THE MAINSERVICE METERPOC/RPASTRING COUNT (INV#1):STRING #1 - 10 MODULESSTRING #2 - 10 MODULESSTRING COUNT INV#2:STRING #3 - 07 MODULESSTRING #4 - 07 MODULES
WARNINGLABELSPV-059/3/2024SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERREVDATEDESCRIPTIONREVISIONSPROJECT NAMESTRUCTURAL STAMPAHJ STAMPAPN #: 221674005020AHJ: CITY OF LAKEVILLEUTILITY: XCEL ENERGYJENNIFER GAUL20890 GOODHUE WAY,LAKEVILLE, MN 550445075812434JALENDE5@YAHOO.COMLABELING DIAGRAM:LABEL #7 TO BE EVERY 10' ON CONDUIT GOING TOJ-BOX ON DC STRINGS (EXPOSED RACEWAY ,COVERS OR ENCLOSURES OF PULL BOXES ANDJUNCTION BOXES, CONDUIT BODIES IN WHICH ANYAVAILABLE CONDUIT OPENINGS ARE UNUSEDRAPID SHUTDOWN FORSOLAR PV SYSTEM10SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWNPV SYSTEM AND REDUCESHOCK HAZARD IN THEARRAY.8 WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!2THIS EQUIPMENT FED BYMULTIPLE SOURCES TOTALRATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEEDAMPACITY OF BUSBARWARNING!3MAXIMUM AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE: 40.00 AMPS 240 VACPHOTOVOLTAIC AC DISCONNECT6PHOTOVOLTAIC POWER SOURCE7MAIN PHOTOVOLTAICSYSTEM DISCONNECT9PARALLELGENERATION ON SITE11SOLAR ELECTRICPV PANELSUTILITY PVAC DISCONNECT13PHOTOVOLTAICSYSTEM CONNECTED14PV METER1516MAXIMUM DC VOLTAGEOF PV SYSTEM378.34VMAIN SERVICE PANELUTILITY METER(DIRECTORY)INVERTER#11182910616713UTILITY OWNED PVPRODUCTION METER15AC DISCONNECT-1910614UTILITY ACDISCONNECT-2INVERTER#217712SOLAR LOAD CENTER -IF USED TO COMBINEPV OUTPUT CIRCUITS17MAXIMUM DC VOLTAGEOF PV SYSTEM264.84VPHOTOVOLTAIC SYSTEMCOMBINER PANELWARNING!12DO NOT ADD LOADS
MULTIPLE SOURCES OF POWER.POWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:CAUTIONPV-05.19/3/2024SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERREVDATEDESCRIPTIONREVISIONSPROJECT NAMESTRUCTURAL STAMPAHJ STAMPAPN #: 221674005020AHJ: CITY OF LAKEVILLEUTILITY: XCEL ENERGYJENNIFER GAUL20890 GOODHUE WAY,LAKEVILLE, MN 550445075812434JALENDE5@YAHOO.COMDIRECTORYPLACARDADDRESS: 20890 GOODHUE WAY, LAKEVILLE, MN 55044MAIN SERVICE PANELDIRECTORY PLACARD:GOODHUE WAY
ROOF ACCESS POINTFRONT OF HOUSE EMERGENCY CONTACT: (541) -200-2896UTILITY AC DISCONNECT AC DISCONNECTNUTILITY METER
EQUIPMENTSPECIFICATIONSPV-069/3/2024SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERREVDATEDESCRIPTIONREVISIONSPROJECT NAMESTRUCTURAL STAMPAHJ STAMPAPN #: 221674005020AHJ: CITY OF LAKEVILLEUTILITY: XCEL ENERGYJENNIFER GAUL20890 GOODHUE WAY,LAKEVILLE, MN 550445075812434JALENDE5@YAHOO.COMSOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #YUKON SERIES SEG-410-BMD-HVVMP31.05VIMP13.21AVOC37.32VISC13.80ATEMP. COEFF. VOC-0.27%/°CSOLAR SHUTDOWN DEVICEMANUFACTURER / MODEL #TESLA SOLAR SHUTDOWN DEVICENOMINAL INPUT DC CURRENTRATING (IMP)13ANOMINAL INPUT SHORTCIRCUIT CURRENT (ISC)17AMAXIMUM SYSTEM VOLTAGE1000 VDCINVERTER SPECIFICATIONSMANUFACTURER / MODEL #TESLA 5.7 KW INVERTER [240V]POWER RATING5700WMAX DC VOLTAGE600VMAX CONT. OUTPUT CURRENT24AMAX CURRENT PER MPPT (IMP)13AMAX SHORT CIRCUIT CURRENTPER MPPT (ISC)17AINV#1VMAX = VOC + ((TLOW - TSTC) X (VOCCOEF X VOC/100))VMAX = 37.32+ (-26-25) x (-0.27 x 37.32/100)VMAX = 37.32+ (-51) x (-0.0101)VMAX = 37.32+ (-51) x (-0.0101)VMAX = 37.32+ 0.5139VMAX = 37.83 VVMAX FOR 10 MODULES = 378.34VDC SYSTEM VOLTAGE OF INVERTER = 600V600/37.83 = 15.86INVERTER SPECIFICATIONSMANUFACTURER / MODEL #TESLA 3.8 KW INVERTER [240V]POWER RATING3800WMAX DC VOLTAGE600VMAX CONT. OUTPUT CURRENT16AMAX CURRENT PER MPPT (IMP)13AMAX SHORT CIRCUIT CURRENTPER MPPT (ISC)17AINV#2VMAX = VOC + ((TLOW - TSTC) X (VOCCOEF X VOC/100))VMAX = 37.32+ (-26-25) x (-0.27 x 37.32/100)VMAX = 37.32+ (-51) x (-0.0101)VMAX = 37.32+ (-51) x (-0.0101)VMAX = 37.32+ 0.5139VMAX = 37.83 VVMAX FOR 07 MODULES = 264.84VDC SYSTEM VOLTAGE OF INVERTER = 600V600/37.83 = 15.86
Model No.
MNSPD-115
MNSPD-300-AC
MNSPD-300-DC
MNSPD-600
Max Operating
Voltage
100 VAC/150VDC
300VAC
385VDC
480VAC/600VDC
Surge Current
per Phase
80kA
80kA
80kA
80kA
Configuration
1 O, 3-wire (2 Legs)
1 O, 3-wire (2 Legs)
1 O, 3-wire (2 Legs)
1 O, 3-wire (2 Legs)
MCOV
180V L-N
470V L-N
470V L-N
780V L-N
SCCR
10kA
10kA
10kA
10kA
VPR 600V/3kA
L_G
600V
1200V
1200V
1800V
O3.527”
4.425”3.82”
24” Wires
O
2”
ires
Performance
Surge Current Rating per Phase 80kA
Short Circuit Current Rating 10kA
Fusing Individually fused MOVs
Thermal Fusing Yes
Over current Fusing Yes
Operating Frequency 0 to 500 Hz
Mechanical Description
Enclosure Polycarbonate UL94V-0
Environmental Rating Type 4X
Connection Method #12 AWG
Weight 1 lb.
Mounting Method 1/2” Conduit Knockout
Operating Altitude Sea Level – 12,000’ (3,658 Meters)
Storage Temp -40o F to +185o F (-40o C to +85o C)
Operating Temp -40o F to +185o F (-40o C to +85o C)
Diagnostics
Blue status LED, one per leg
Listings and Performance
UL Standard for Safety, UL 1449 Surge Protective Devices-Fourth Edition
CSA C22.2 No. 8-M1986 Electromangetic Interference (EMI) Filters, Fourth Edition
Diagnostic Blue LED
Thermal Disconnector Internal Fuse
Response Time <1 micro sec.
MNSPD-115
0 to 90 VAC
0 to 115 VDC
180V
600V
Up to 90VAC circuits,
12V, 24V, 48VDC battery
circuits
UL1449 4th Ed. Type 1
MNSPD-300-AC
0 to 250 VAC
470V
1200V
120/240 VAC circuits
UL1449 4th Ed. Type 1
MNSPD-300-DC
0 to 300 VDC
470V
1200V
Off-grid PV combiners
Charge controller inputs
up to 300VDC
UL1449 4th Ed. Type 1
MNSPD-600
0 to 480 VAC
0 to 600 VDC
780V
1800V
316V/480 VAC circuits
Grid-tie PV combiners
Grid-tie inverter input
Non-Isolated Inverters
UL1449 4th Ed. Type 1
PART NUMBER
Nominal Voltage
MCOV
VPR Line to Ground
Suggested Placement
Type
MNSPD-300-AC
LED indicates when voltage is present between L1 + ground and L2 + ground
MNSPD-115, MNSPD-300-DC and MNSPD-600:
LED indicates when voltage is present between L1 + L2 (PV+ PV-)
www.midnitesolar.com/spd
19115 - 62nd Ave NE, Arlington, WA 98223 PH. 360-403-7207 FAX 360-691-6862
MidNite Surge Protection DevicesMidNite Surge Protection Devices