HomeMy WebLinkAbout17667 Empire TrlCITY OF LAKEVILLE CERTIFICATION OF GRADING AND FINAL PLACEMENT OF IRON MONUMENTS Building Permit #: LA223693 Legal Description: Lot 17 Block 1_ Subdivision: PHEASANT RUN OF LAKEMLLE SEVENTH ADDITION Address: 17667 Empire Trail We ­k hereby certify that on 28th_ day of October , 2024 an inspection of this property was conducted by me or under my direct supervision and that the as -built grades, elevations and drainage patterns of the site and building are in conformance with the grading plan approved by the City Engineer or amendments previously approved by the City Engineer. (EXCEPT AS NOTED ON INCLUDED SURVEY) In addition, all property corner monuments are in place as of this date. I hereby certify that this survey, plan or report was prepared by me or under my direct supervision and that I am a duly Licensed Land Surveyor under the laws of the State of Minnesota. Print Name: P ter/J. Hawkinson Signature: Date: October 29, 2024 MN License #: 42299 NOTE: ATTACH A COPY OF THE CERTIFICATE OF SURVEY SHOWING ALL AS - BUILT GRADES, ELEVATIONS AND DRAINAGE PATTERNS Approved subdivision grading plans should be obtained from the property owner or developer. General questions relating to the building permit should be directed to the Building Inspections Department at 952-985-4440. Questions relating to grading should be directed to the Engineering Department at 952-985-4500. Prior to release of the Grading Security, this document shall be filed with: City of Lakeville Engineering Department 20195 Holyoke Avenue Lakeville, MN 55044 Ends. 1 RECEIVED By Alanna Sobottka at 8:52 am, Nov 08, 2024 A^SDSH AJO P S2VtC'ell icatim, of Omdmu L'KEV=doc IZ � 9Lls /\ z I W I m Q�]5 - 9R].B I ) 9R16 O t [ 9R].69L1.] O I 1 oho •_'� Q I,', I BR35 M d C I•' o I � Z I I` r F)1 4 N1.1 1235 9217921s c3 O N constraotmn Notes: 1. Install rack construction entrance. 2. Install silt fence as needed for erosion control. 3. Sidewalks shall drain away from house a minimum of 1.0%. 4. Contractor must verify driveway design. 5. Contractor must verify service elevation prior to construction. 6. Add or remove foundation ledge as required. 7. Retaining walls are conditional; Wall installed if the grade exceeds 3:1. Wall will not be installed if the grade is 3:1 or less. General Notes: 1. Grading plan by KJ Walk, Inc lost doted 09-16-2021 was used to determine proposed elevations shown herein. 2. This survey does not purport to show improvements or encroachments, except as shown, as surveyed by me or under my direct supervision. 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4. No specific soils investigation has been performed on this lot by the surveyor. The suitability of sails to support the specific house proposed is not the responsibility of the surveyor. S. This certificate does not purport to show easements other than those shown on the recorded plat. 6. Bearings shown ore based on an assumed datum. s N EAST I I %9Ra.9 %BRa.B %921.9 Y %821A z9225 % 921.9 yacc^1 %921A -iah. '013 --- \e�lazo.e xBa.z 40 1r x 92LB % 9RRA x922 a % 922.0 � 9RA] I BR0.9 % 921.4 8R2Ax 9R29 a V 22.0 Y = I au a I �9210.]G 171/- se. O V 8 •0 19R0.8 x .21.5 8222 % E N �� - 69.0 -I- 92L2 9 .a I I r I 92A8 \ 40 54 150.10 I 92].2 x 928.6 % BR6A % B21.1 %Use x.1na .,.. .. __. n9201 % 921.4 _ 822} BR26 82A6 9RA9 see / „B2na %9RR.1 % 919.2 0 .211 92].] 10 22'0 tM 8 B2sO BR].9 lit °2.0/N 7�21] 92]611 O 91 Lis k eze.] 92] 41 92s.2 N, lPf %921.1 %B21.fi %922.] X92d.0 %9RSs XBLl6 X NX9L11 EAST m Vacant • Denotes Iron pipe 'e(f Denotes service oenntes television bex ■ Denotes electric box p Denotes teleph5ne box x poll Denotes existing elevation ( 000.00) Denotes prep ... d elevation Denotes drainage flow direction ♦ Denotes spike Denotes proposed retaining wall designed and built by others. vl X.2. 922] 150.15 Lot area = 10511 SF House a = 2158 SF Porch area = 113 SF Lowest floor elevation per grading plan : 919.0 House elevations (Proposed) / As built Lowest Floor Elevation :(919.7) / Top Of Foundation Elev :(927.7) / 927.6 Garage Slab Elev. 0 Door :(927.3) / 927.4 T.O.F. Elevation 0 Lookout:(922.9) / 923.1 O 0 � O O Q O) L C c ZW� � C w ay �Vy sis vc ow U Um JOO j OJ m5 $� PO O F9m w m � riY �J 3 N O r% 'E LU om Edm o6 w J O QD jO a r co O 1 "X O V U v Q o w x a Sidewalk area = 30 SIF E W emE 'a Driveway area = 730 SF 0' t0' 20' Total Impervious Area - 3031 SIF Impervious Coverage = 26.64k ,oev g REVISED 9/24/24 GRADING AS -BUILT s REVISED 10/7/24 GRADING AS -BUILT Scale: 1' = 20' ewe ^ m Benchmark: 5 hereby certify to Brandt Anderson Homes Inc that this survey , plan To Nut Hydrant P� L20 B2 J ' e or report was prepared by me or under my direct supervision, that Elevation = 923.67 1 On eand o am a duly licensed Land Surveyor under the laws of the State of ey 1 ro Minnesota, dated 04/04/24. y$Z t$ Signetl: i eer E gineering, P.A. aBY:4 F 3A Rzsheuv<i wail 6'9u Peter J. Hawkinson, Professional Land Surveyor _ m Minnesota License No. 42299 emoil-phawkinson0pioneereng.com