Loading...
HomeMy WebLinkAboutItem 05a - D.R. Horton Inc VarianceCity of Lakeville Community Development Memorandum To: Planning Commission Kris Jenson, Planning Manager May 15, 2025 Packet Material for the May 22, 2025 Planning Commission Meeting 4824 171st Street Garage Size Variance D.R. Horton, Inc. – Minnesota, on behalf of Dayitwa Shrestha and Renu Lakhemaru. has submitted a variance application for an attached garage of less than 540 square feet and a width of less than 22 feet for the home at 4824 171st Street West. Construction of the home was completed and conveyed to the current homeowners in March 2025. The zoning of the property is RST-2, Single and Two-Family Residential District. The following exhibits are attached for your review: A. Location map B. Applicant narrative C. Survey D. Floor Plan Section 11-18-7.D of the Zoning Ordinance includes minimum size standards for single family home attached garages. The minimum floor area of an attached garage for a dwelling without a basement is 540 square feet with a minimum width of 22 feet. The minimum floor area for an attached garage with a basement is 480 square feet. These measurements are based on interior dimensions. 2 Shortly after the homeowners took possession of their home, they contacted Community Development staff to inquire about the minimum size for an attached garage in a single family home. Staff responded via email a day or so later, but in the interim, Staff was contacted by representatives from DR Horton. They had been contacted by the homeowners regarding the garage size, and it was determined that the attached garage constructed with the home did not meet the minimum garage size for area and width. When the building permit was submitted, it should have included a bump out on the side of the garage such that the minimum garage area would be at least 540 square feet and the width 22 feet. Those measurements are the minimum requirements for a home that is a slab on grade (no basement). This was an error on DR Horton’s part. When the building plans were reviewed by Building Inspections staff, they also missed that the garage did not include the additional bump out area to increase the garage area and width. This was an error on the City’s part. The permit was issued and the home was constructed. The garage as constructed is 481 square feet in area and 20 feet in width. Upon learning of the error at 4824 171st Street, Inspections staff reviewed all of the issued permits for single family homes without a basement in the Brookshire development and confirmed that all of the previous permits issued for similar homes meet the minimum area and width requirements. Approval of this variance request would remove the non-conformity status of the garage, meaning the structure is considered legal and conforming. The variance form would be recorded with Dakota County so that the legal and conforming status is known and available to any future buyers of the home. Section 11-6-5 of the Zoning Ordinance states that the board of adjustment (City Council) shall not approve any variance request unless they find failure to grant the variance will result in practical difficulties. “Practical difficulties” means that the property owner proposes to use the property in a reasonable manner not permitted by the Zoning Ordinance and that economic considerations alone do not constitute practical difficulties. The following review criteria must also be met: Single family homes are consistent with the low-density residential land use designation. A two car garage is the minimum requirement for a single family home and therefore is in harmony with the general purposes and intent of this title. 3 C. That the plight of the landowner is due to circumstances unique to the property not created by the landowner. The homeowner did not create this situation; it is due to an error on the part of DR Horton and the City of Lakeville. D. Not applicable. There are other single family homes in the Brookshire development which have two car garages. That the attached garage at 4824 171st Street does not meet the minimum area and width is not noticeable from outside the structure and therefore will not alter the essential character of the neighborhood in which the home is located. The home and garage are constructed and therefore the granting of the requeted variance is the minimum action required to eliminate the practical difficulty. Not applicable; single family homes are a permitted use in the RST-2 District. Community Development Department staff recommends approval of the variance for minimum garage area and width at 4824 171st Street, on the basis that the review criteria have been met. Findings of Fact are attached for consideration. Dakota County, Maxar, Microsoft EA G L E V I E W D R 170TH ST 4824 171ST ST City of Lakeville 4824 171st St Variance Location Map EXHIBIT A DRAFT HORSE BLVD 171ST ST DRAPER WAY DY S A R T P L A C E DURHAM DR 173RD ST EXHIBIT B EXHIBIT C These plans, and the concept thereof or used without written consent. And may not be reproduced are the exclusive property of D.R. Horton Inc., COPYRIGHT D.R. HORTON, INC. 2022C 3.0 X X427 HOLCOMBE PC#1155: 12-29-23-LLPC#1133,1141,1143: 9-14-2023-LL PERMIT/CONSTRUCT: 7-29-24-RK LIVING ROOM DINING 942 SQ. FT. NOTES:-9'-1 1/8" PLATE HEIGHT TYPICAL-WDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)-TYP. FIRST FLOOR WINDOW HEAD HEIGHT AT 7'-11 3/8" U.N.O.-BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFR 14'-0"x8'-0"CONC PATIO 2ND FLOOR PLAN 1/4"=1'-0" NOTES:-8'-1 1/8" PLATE HEIGHT TYPICAL-WDW SIZES GIVEN IN FEET AND INCHES (WIDTH x HEIGHT)-TYP. SECOND FLOOR WINDOW HEAD HEIGHT AT 6'-11 3/8" U.N.O.-BEAM & HEADER SIZES TO BE VERIFIED BY SUPPLIER/MFR 1381 SQ. FT. LIVING AREA 1ST FLOOR PLAN 1/4"=1'-0" 35'-0" 9'-4" 41 ' - 6 " 16 ' - 9 " 7'-2" 41 ' - 6 " 15 ' - 0 " 16x7 OVERHEAD DOOR 20'-0" 10'-6 1/2" 21'-0 1/2" 35'-0" 11 ' - 6 " 5'-0"5'-0" 2x6 BRNG WALL 2x6 BRNG WALL 6'-1" 20'-0" 26 ' - 0 " 2-8 PED. PWDRHD-FLR 7' - 3 1 / 2 " 3' - 6 " 3' - 6 " W/ WOOD CAP42" HIGH ANGLED WALL UP 16 R 14'-0" 2W 3050 SH3050 SH 6'-6" 6'-6" 4'-10 1/4" 3'-6" BEDRM #1 LAU. HD-FLR DRYERWASHER W.S. LOFT 14'-8"6'-4 1/2" BEDRM #3 21'-0 1/2" W.I.C. CPT. 26 ' - 6 " 5' - 1 1 1 / 2 " FLEX CLEAR FRAMING 11 ' - 1 3 / 4 " I N S I D E F R A M I N G 20 AMP.MICRO HOODCIRCUIT RANGE 2'-4" SI N K DW 2x 6 W A L L 7' - 1 " 7' - 0 " C A B T S . 3'-6" TOP 7' - 4 " T O P 3' - 5 " 3' - 3 " 8'-7" 2-4 2' - 4 " KIT VE N T H O O D TO O U T S I D E REF. 3'-0 5 / 8 " 15'-0" 1' - 6 " 35'-0" 13'-10" 7'-2" 2x6 3' - 6 " 3' - 6 " W/ W O O D C A P 42 " H I G H H A L F W A L L DN 16 R 2W 3050 SH 9'-8" BATH #2 HD-FLR 36" 5- 0 F B G L TU B / S H W R 2'-10" TP H TOWEL BAR 7' - 0 " 8' - 1 " 41 ' - 6 " 2' - 6 " 2' - 6 " 11 ' - 1 " 41 ' - 6 " 30 ' - 0 " 16 ' - 9 " 11 ' - 6 " 7' - 3 1 / 2 " 5' - 1 1 1 / 2 " 2' - 7 3 / 4 " 10'-0" 35'-0" 3'-11 1/2" BEDRM #4 6'-1 1/2" 1' - 6 " BEDRM #2 6' - 3 1 / 2 " 6' - 6 1 / 2 " 12 ' - 1 0 " MECH 20 ' - 0 " AHU METERRISER AIREXCHGR F.D. UNFIN.WHTANKLESS 4- 3 S R O 2' - 0 " 7' - 3 " 6'-10" 5'-4 1/2" TOWEL RING BATH #1 HD-FLR 34x60 FBGLSHWR 72" TPH TOWEL BAR 12'-0" 6' - 0 " 5'-0"5'-0"4'-6 1/2" 9'-5" 4'-2" CONC PORCH73 SQ. FT.16" WIDE DROPPED SOFFIT(SEE SECTION)DROPPED BEAM 3' - 1 0 " 8" 3'-6" 3' - 6 " 1'-11 1/2" 8"8" TYPICAL PORCH COLUMN:6x6 TREATED POST WITHIN10" SQUARE BOXED COLUMN 2'-0" 1'-6" 2040 SH F.D. 22x30ATTICACCESS WATER NOTE:FRAMER TO ROCK , POLY & INSULATEMECH ROOM EXTERIOR WALLS PRIORTO MECH EQUIPMENT BEING INSTALLED 3050 SH TEMP3050 SH 3050 SH 3-0 DR 2W 3050 SH 14 " M F D F L O O R T R U S S E S IN S T A L L P E R M F R S S P E C S MF D T R U S S E S A T 2 4 " O . C . MF D T R U S S E S A T 2 4 " O . C . RADONVENT PIPE RADONVENT PIPE SILLCOCK A/C 2-4 2-4 2-8 2-4 2-4 2-4 2-4 2-4 2-6 2-8 2-8 2-6 2-62-6 4-0 6068 SGD 4'-5" 10'-6" 1' - 5 " TEMP W.I.C. CPT. W.I.C. CPT. 6'-2 1/2" CLEAR FRAMING 3' - 1 0 1 / 2 " 1' - 6 " 1' - 6 " 7'-0"7'-8" 2W 3050 SH2W 3050 SH HD-FLR HD-FLR HD-FLR CPT. FOYERHD-FLR 5'-4 1/2"8 1/2" 3'-6 3/4" SEWERCLEANOUT CPT.CPT. CPT. CPT. CPT. 2x 6 2x6 10 " 2-6 2-6 WINDOW & DOOR SCHEDULE - MAIN LEVEL CALL-OUT U-FACTOR ROUGH OPENINGLOCATIONSHGC# 3-0 DR 0.31FOYER 0.231 1 DINING ROOM6068 SGD 3050 SH KITCHEN1 0.31 72 1/8" X 80"0.32 0.31 0.31 36 1/4" X 60 1/4" WINDOW & DOOR SCHEDULE- UPPER LEVEL CALL-OUT U-FACTOR ROUGH OPENINGLOCATIONSHGC# 3050 SH 1 CLOSET 0.31 36 1/4" X 60 1/4"0.31 2W 3050 SH 1 BEDROOM #1 0.31 0.31 72 1/8" X 60 1/4" 2 BEDROOM #3 0.31 0.313050 SH 36 1/4" X 60 1/4" 38 1/4" X 83 1/4 2W 3050 SH 1 FLEX RM 0.31 0.31 72 1/8" X 60 1/4" 1 BATH #12040 SH 0.31 24" X 48"0.31 3050 SH 1 STAIRS 0.31 36 1/4" X 60 1/4"0.31 3050 SH 1 BEDROOM #2 0.31 36 1/4" X 60 1/4"0.312W 3050 SH 1 LIVING ROOM 0.31 0.31 72 1/8" X 60 1/4" 1 BEDROOM #4 0.31 0.313050 SH 36 1/4" X 60 1/4" 1 BEDROOM #4 0.31 0.312020 FX 24" X 24" 4' - 6 " 3' - 1 0 " 8" 9'-0"4'-8" ELEC FIREPLACE 3/16"=1'-0" 5'-6" 1' - 4 " 18-1/4"x44-1/2" S/R 1' - 6 1 / 4 " RGH OPGALLUSION 48 ELEC FP 1' - 4 " 1' - 6 1 / 4 " 10 " 2X 6 W A L L 2-2X10 1/2" PLYWD 2X6 FRAMING INSULATION & 1 LAYEROF ROCK BY FRAMERS MANTLE 4' - 2 " 1/2" ROCK OVER ROCK RETURNSOF FIREPLACE OPG. +- 3'-8 1/2" 10 3/4"10 3/4" GARAGE 4" CONC FLOOR 505 SQ. FT. (OUTSIDE) TYPICAL 2x6 GARAGE WALLS 481 SQ. FT. (INSIDE) DRP BEAM SILLCOCK 10'-6" WSFUT 2x6 46 ' - 0 " OUTLET INSTALLED20AMP DEDICATED ON SIDE WALL OFFIREPLACE OPGDO NOT 14 " M F D F L O O R T R U S S E S IN S T A L L P E R M F R S S P E C S 16 " M F D F L O O R T R U S S E S IN S T A L L P E R M F R S S P E C S 2" STEP INWALL HEIGHTS 2" STEP INWALL HEIGHTS NOTE: INSULATORS TOSPRAY FOAM MECHANICALROOM CEILING AT SAMETIME AS RIM BOARD ADDITIONAL NOTESINTERIOR SWING DOORS: RGH OPG HGT IS 83", THE WIDTH IS THE SIZE OF THE DOOR PLUS 2"INTERIOR BI-FOLD DOORS: RGH OPG HGT IS 82", THE WIDTH IS THE SIZE OF THE DOOR PLUS 1-1/2" DO NOT POLY TECH TUBEOUTLET & SET R.O.HEIGHT AT7'-11 3/8"ABOVELANDING ANGLEDWALL ON ALL WALLS & CEILINGGYP. BOARDNOTE: PANIC PAN 16X36 MECHANICAL SOFFIT 4-0 2' - 2 1 / 4 " 6'-4 1/4" 2' - 6 " 12 ' - 7 3 / 4 " 3' - 2 " 1' - 1 0 1 / 4 " 14'-6" MUD RMHD-FLR STOP SHELVINGHERE EL E C . F P 5' - 6 " 4' - 3 " IRRIGATION SYSTEM PLAN OPTIONS LIVING ROOM HD-FLR ELECTRIC FIREPLACE IRRIGATION SYSTEM - PERMIT/CONSTRUCT PLANS 4824 171ST STREET WEST LOT 12 BLOCK 6 - BROOKSHIRE -Min. 15" clearance to any obstruction from center of W.C., 24" in front(typ). 3.9 (2)7-1/4 LSL (2)7-1/4 LSL (2)7-1/4 LSL 3-1/2 x 9-1/2 LSL 3-1/2 x 9-1/2 LSL 3-1/2 x 7-1/4 LSL 3-1/2 x 7-1/4 LSL 3-1/2 x 7-1/4 LSL 3-1/2 x 7-1/4 LSL (3) 18" LVL Shearwall PFHPFH EXHIBIT D 1 CITY OF LAKEVILLE DAKOTA COUNTY, MINNESOTA 4824 171ST ST VARIANCE FINDINGS OF FACT AND RECOMMENDATION The Lakeville Planning Commission met at its regularly scheduled meeting on May 22, 2025 to consider the application of D.R. Horton, Inc, - Minnesota, on behalf of Dayitwa Shrestha and Renu Lakhemaru, for a variance to allow an attached garage of less than 540 square feet and a width of less than 22 feet for the home at 4824 171st Street. The Planning Commission conducted a public hearing on the variance application preceded by published and mailed notice. The applicant was present, and the Planning Commission heard testimony from all interested persons wishing to speak. 1. The subject property is located in Comprehensive Planning District 3, which guides the property for low density residential use. 2. The subject site is zoned RST-2, Single and Two-Family Residential District. 3. Legal description of the property is: Lot 12, Block 6, Brookshire 4. Chapter 6 of the City of Lakeville Zoning Ordinance provides that a variance shall not be approved unless failure to grant the variance will result in practical difficulties. The criteria and our findings regarding them are: Finding: Single family homes are consistent with the low-density residential land use designation. Finding: A two car garage is the minimum requirement for a single family home and therefore is in harmony with the general purposes and intent of this title. 2 Finding: The homeowner did not create this situation; it is due to an error on the part of DR Horton and the City of Lakeville. Finding: Not applicable. Finding: There are other single family homes in the Brookshire development which have two car garages. That the attached garage at 4824 171st Street does not meet the minimum area and width is not noticeable from outside the structure and therefore will not alter the essential character of the neighborhood in which the home is located. Finding: The home and garage are constructed and therefore the granting of the requeted variance is the minimum action required to eliminate the practical difficulty. Finding: Not applicable; single family homes are a permitted use in the RST-2 District. 5. The report dated May 15, 2025 prepared by Kris Jenson, Planning Manager is incorporated herein. The Planning Commission recommends that the City Council approve the variance based upon the foregoing information, findings, and the considerations and stipulations outlined in the Planning Report dated May 15, 2025, prepared by Kris Jenson, Planning Manager. LAKEVILLE PLANNING COMMISSION BY: __________________________ Christine Zimmer, Chair