HomeMy WebLinkAbout8551 183rd St WIX CB
183rd STREET W T p3'a3931 g. RCP)S
1=1011 'M (18"RCP)W
----- --1--- - �_,_ --
I I
LEGEM
Proposed Building
--- > ---
SanitaryLine
---I---
Water Line
— — — OR — — —
Storm Line
Inch Monument Found
RLS 45817
d
Cleanout
®
Curb Stop
OManhole/Catch
Basin
V
Fire Hydrant
W
Water Valve
p
Offset Imn
— — — 981 — — —
Existing Contour
Proposed Contour
—992 —
Proposed Spot Elevation
'di
Existing Spot Elevation
,day
—y
Surface Drainage Direction
GRADING QUANTITIES (CY)
Call, Common Cut
-318
Call, Common Fill
34
Driveway'
-22
Basement Slab
-37
Contrasted Amount
-50
Additional Amount
-0
Send
Swett 20%
69
Total Cut
-434
Total Fill
416
Total (±)
-18
Note qua nmg
excav anon and
driveway and lot grladingo�
CONSTRUCTION NOTES:
1. Install rock construction entrance.
2. Install silt fence as needed for erosion.
3. Sidewalks shall drain away from house a minimum
of1%
4. Contractor must verify driveway design.
5. Contractor must verify service elevation priorto
construction.
be Add or remove foundation ledge as required.
GENERAL NOTES:
1. Grading plan by ISG last dated May 9, 2022 was
used to determine proposed elevations shown
hereon
2. This survey does not purport to show improvements
or encroachments, except as shown, as surveyed by
ISG or under my direct supervision.
3. Proposed building dimensions shown are for
horizontal location ofstructums on the lot only.
Contact builder prior to construction for approved
construction plans.
4. No specific soil investigation has been performed on
this lot bythe surveyor. The suitability ofsoils to
support the specific house proposed is not the
responsibility ofthe surveyor.
5. Ifbuilding footprint exceeds the building pad,
additional earthwork and testing will be required to
meet the requirements as outlined within the
geotechnical report.
fi. This certificate does not purport to show easements
otherthan those shown on the recorded plat.
1. Bearings shown are based on the Final Plat.
8. Site address is 8551 183rd Street W, Lakeville, MN
55044
9. House/Basement type. Itasca EH09 A3- Left -Full
Basement
10. Building dimensions shown are based on First Floor
Plan
11. Proposed Contours are shown hereon.
12. Topographic surveywas completed on March 1,
2025
BENCHMARK:
Top nut fire hydrant located in the NE quadrant of
Hideaway Trail and Highview Avenue.
Elevation = 1038.03 feet
AREA TABLE:
House/Garage Area = 2, 183 sq. If
Porch Area = 78 sq. ft.
Dnveway=alk Area = 848 so. If
Total Impervious Area = 3,109 sq. If
Lot Area = 11 312 sq If
Impervious Coverage = 21.5%
HOUSE ELEVATIONS: Pmposed/As-Built
Garage Floor= 1041.8
Top of Foundation = 1042.1
Lowest Floor= 1034.1
Lowest Opening= 1042.1
N
20
a®
SCALE IN FEET
PROJECT
LENNAR
CORPORATION
CASLANO 2nd
LOT 12, BLOCK 2
IAKEMILLE MINNESOTA
DATE DESCRIPTION R,
PROJECT NO 11 2—
DESIGNED By
CLIENT PROTECT NO
TITLE
CERTIFICATE
OF SURVEY
,xEsr I OF 1