Loading...
HomeMy WebLinkAbout8594 183rd St W1 II LEGEND =1039d3(15"RCP)E Proposed Building1=1039 79 (il"RCP)W SanitaryLine 20 ---" --- Storm Line 1 / Q 83 O inn Monument Found 4 4�'0 I N:1]]2 14 RLS4s817 rC/ <7R �E:5200 3.51 �?ea Q Cleanout A Curb Stop ygr�"SD f / OSEOI� I1 O p Manhole/Catch Basin WdA61 � 1 5.1%SLOPE 9^ ■ rv� • Post _ s77 ^� I ■ I 1 Light Pole j � � � L= j / iaygB ❑ Offset Iron vWa /i / PROPOSED a �C t �� 104314 - - - 981 - - - Existing Contour l // 1014- i(yz i �rt1e RAGE 1018.I0 <� 300 � _�z_ Proposed Contour 1� y1lI \� ��// all Proposed Spot Elevation \ i I 8594-ji&FfilW 12- 5Existing Spot Elevation 0 , PROPOSE0. / 1040 �Surface Drainage Direction WALKOUT I �O 100— r CIO fosg_ S 71038 v�4'B.la T I it I 1/ I I I j I I 1 .igx. N:1 ]]104 46 E520021.93 0 —1034 _ R — GRADING QUANTITIES (CY) Call, Common Cut -85 Call, Common Fill 332 Drive vi -22 Basement Slab -27 Contracted Amount -71 Additional Amount -0 Send ] Snell 20% 55 Total Cut -212 Total Fill 398 Total(±) 186 NOtG qua ding excav anon and tlriveway and lldi grladingd� CONSTRUCTION NOTES: 1. Install mck construction entrance. 2. Install silt fence as needed for erosion. 3. Sidewalks shall chain away from house a minimum 0f1% 4. Contractor must verify driveway design. 5. Contractor must verify service elevation priorto construction. be Add or remove foundation ledge as required GENERAL NOTES: 1. Grading plan by ISG last dated May 9, 2022 was used to determine proposed elevations shown hereon 2. This survey does not purport to show improvements or encroachments, except as shown, as surveyed by ISG or under my direct supervision. 3. Proposed building dimensions shown are for honzontal location ofstructures on the lot only. Contact builder prior to construction for approved construction plans. 4. No specific soil investigation has been performed on this lot bythe surveyor. The suitability ofsoils to support the specific house proposed is not the responsibility ofthe surveyor. s. Ifbuilding footprint exceeds the building pad additional earthwork and testing will be required to meet the requirements as outlined within the geotechnical report. fi. This certificate does not purport to show easements otherthan those shown on the recorded plat. 1. Bearings shown are based on the Final Plat. 8. Site address is 8594 183rd Street W, Lakeville, MN 55044 9. House/Basement type: Lewis EK05 B3- Right - Walkout 10. Building dimensions shown are based on First Floor Plan 11. Proposed Contours are shown hereon. 12. Topographic surveywas completed on Apnl 29, 2025 BENCHMARK: Top nut fire hydrant located in the NE quadrant of Hideaway Trail and Highview Avenue. Elevation = 1038.03 feet AREA TABLE: House/Garage Area = 1,8]4 sq. ft. Porch Area = 130 sq. ft. Unveway=alk Area = 856 so. ft. Total Impervious Area = 2 860 sq. ft. Lot Area = 10 253 sq ft. Impervious Coverage = 27.9% HOUSE ELEVATIONS: Proposed/As-Built Garage Floor= 10467' Top of Foundation = 104].0 Lowest Opening= 1039.0 RICE = 1038.5 Raised 0 5' N 20 B® SCALE IN FEET �� MARK A SCHWARZ /r�rt.2 Q_ PROJECT LENNAR CORPORATION CASLANO 2nd LOT 3, BLOCK 4 IAKEMILLE MINNESOTA