HomeMy WebLinkAbout8594 183rd St W1
II LEGEND
=1039d3(15"RCP)E Proposed Building1=1039 79 (il"RCP)W
SanitaryLine
20
---" --- Storm Line
1 / Q 83 O inn Monument Found
4 4�'0 I N:1]]2 14 RLS4s817
rC/ <7R �E:5200 3.51
�?ea Q Cleanout
A Curb Stop
ygr�"SD f / OSEOI� I1 O p Manhole/Catch Basin
WdA61 � 1 5.1%SLOPE 9^ ■ rv� • Post
_ s77 ^� I ■ I 1
Light Pole
j � � � L= j / iaygB ❑ Offset Iron
vWa /i / PROPOSED a �C t �� 104314 - - - 981 - - - Existing Contour
l // 1014-
i(yz i �rt1e RAGE 1018.I0 <� 300 � _�z_ Proposed Contour
1� y1lI
\� ��// all Proposed Spot Elevation
\
i I 8594-ji&FfilW 12- 5Existing Spot Elevation
0
, PROPOSE0.
/ 1040
�Surface Drainage Direction
WALKOUT I �O
100—
r
CIO
fosg_
S
71038 v�4'B.la
T I it
I
1/
I I I
j I I 1
.igx.
N:1 ]]104 46
E520021.93
0
—1034 _ R —
GRADING QUANTITIES (CY)
Call, Common Cut
-85
Call, Common Fill
332
Drive vi
-22
Basement Slab
-27
Contracted Amount
-71
Additional Amount
-0
Send
]
Snell 20%
55
Total Cut
-212
Total Fill
398
Total(±)
186
NOtG qua ding
excav anon and
tlriveway and lldi grladingd�
CONSTRUCTION NOTES:
1. Install mck construction entrance.
2. Install silt fence as needed for erosion.
3. Sidewalks shall chain away from house a minimum
0f1%
4. Contractor must verify driveway design.
5. Contractor must verify service elevation priorto
construction.
be Add or remove foundation ledge as required
GENERAL NOTES:
1. Grading plan by ISG last dated May 9, 2022 was
used to determine proposed elevations shown
hereon
2. This survey does not purport to show improvements
or encroachments, except as shown, as surveyed by
ISG or under my direct supervision.
3. Proposed building dimensions shown are for
honzontal location ofstructures on the lot only.
Contact builder prior to construction for approved
construction plans.
4. No specific soil investigation has been performed on
this lot bythe surveyor. The suitability ofsoils to
support the specific house proposed is not the
responsibility ofthe surveyor.
s. Ifbuilding footprint exceeds the building pad
additional earthwork and testing will be required to
meet the requirements as outlined within the
geotechnical report.
fi. This certificate does not purport to show easements
otherthan those shown on the recorded plat.
1. Bearings shown are based on the Final Plat.
8. Site address is 8594 183rd Street W, Lakeville, MN
55044
9. House/Basement type: Lewis EK05 B3- Right -
Walkout
10. Building dimensions shown are based on First Floor
Plan
11. Proposed Contours are shown hereon.
12. Topographic surveywas completed on Apnl 29,
2025
BENCHMARK:
Top nut fire hydrant located in the NE quadrant of
Hideaway Trail and Highview Avenue.
Elevation = 1038.03 feet
AREA TABLE:
House/Garage Area = 1,8]4 sq. ft.
Porch Area = 130 sq. ft.
Unveway=alk Area = 856 so. ft.
Total Impervious Area = 2 860 sq. ft.
Lot Area = 10 253 sq ft.
Impervious Coverage = 27.9%
HOUSE ELEVATIONS: Proposed/As-Built
Garage Floor=
10467'
Top of Foundation =
104].0
Lowest Opening=
1039.0
RICE =
1038.5
Raised 0 5'
N
20
B®
SCALE IN FEET
�� MARK A SCHWARZ
/r�rt.2 Q_
PROJECT
LENNAR
CORPORATION
CASLANO 2nd
LOT 3, BLOCK 4
IAKEMILLE MINNESOTA