HomeMy WebLinkAbout18130 Hounds Dr SurveyHOU
N
D
S
D
R
I
V
E
37
18130 Hounds Dr
10.34'os bc on line NE
25898
0.00
bc
9.83'os bc on line NE
1045
.
6
0
1046.62
1037.02
10
3
3
.
4
5
1033.50
1033
.
1
8
1046.44
1044
.
4
7
1047
.
2
6
1047
.
6
6
10
4
6
.
7
7
104
6
.
4
2
1045
.
6
7
1045.99
1045
.
2
2
10
4
4
.
5
5
U
I
I
I
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>
>
>
>
>>
>>
>
>
>
I
I
I
I
PROPOSED
WALKOUT
PROPOSED
GARAGE
PROPOSED
DRIVEWAY
5.0% SLOPE
(to walk)
Buildi
n
g
S
e
t
b
a
c
k
Drainag
e
a
n
d
U
t
i
l
i
t
y
E
a
s
e
m
e
n
t
N:178197.02
E:519748.49
I=1032.97 (OTHER" RCP) SUMP SUMP HAS DROP OFF FROM SW PIPE TO E PIPE
EX CB
T/C=1044.97
EX CB
I=1030.53 (24" RCP) SE
I=1030.34 (24" RCP) N
1034
.
6
4
1034
.
2
9
EX DROP INTAKE
R=1033.14
I=1030.66
I=1
0
4
0
.
4
2
R=1034.00
EX CB
I=1028.36 (30" RCP) N
I=1028.44 (30" RCP) S
I=1029.60 (15" RCP) SW
R=1036.38
I=1033.00 (12" PVC) NE
I=1033.04 (12" PVC) S
S43
°
1
0
'
4
6
"
E
1
3
5
.
2
5
PORC
H
N:178306.86
E:519726.42
L=61.88
R=130.00
Δ=27°16'17"
4.00
6.0
4
8.00
21
.
4
6
6.0
0
23.5
4
44.
0
0
L=88.00
R=340.00
Δ=14°49'43"
N59°
4
7
'
5
5
"
E
35.5
2
S1
5
°
5
4
'
2
9
"
E
1
2
5
.
0
4
13.62
12.504.0
06.04
8.0
0
21.46
4.0
0
10.0
0
6.00
23
.
5
4
44.00
25.68
13.77
24.99
44
.
0
0
20
.
4
6
6.0
10.0
2.0
10.04.0
18.5
10
4
6
.
9
5
1044
.
3
3
1038
.
3
6
1041.63
1036
1038
1040
1042
1044
1046
10
4
6
1044
1040
1042
104
6
10
4
8
10
3
8
.
8
0
103
7
.
0
6
104
5
.
5
6
HP
104
5
.
2
9
1047.22
104
7
.
5
0
104
7
.
5
0
104
4
.
6
0
1038.8
0
103
8
.
7
2
1047.07
104
6
.
9
5
10
4
6
.
9
5
1036
.
8
7
1033.7
9
103
4
.
9
9
EOF
10
3
9
.
3
0
1039.307
30
10
10
5 10
25
50
.
4
104
7
.
2
4
HP
20
26
10
3
7
.
2
4
EO
F
1047.50
104
4
.
5
0
104
7
.
5
0
14.3
3
12.79
25303 L37 B5
DATE
REVISION SCHEDULE
DESCRIPTION BY
PROJECT NO.
CAD FILE NAME
DRAWN BY
DESIGNED BY
ORIGINAL ISSUE DATE
CLIENT PROJECT NO.
REVIEWED BY
PROJECT
SHEET
TITLE
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
FI
L
E
L
O
C
A
T
I
O
N
:
S:
\
P
R
O
J
E
C
T
S
\
2
5
0
0
0
P
R
O
J
\
2
5
3
0
0
-
2
5
3
9
9
\
2
5
3
0
3
S
T
R
E
E
F
L
A
N
D
P
R
O
P
E
R
T
Y
-
L
E
N
N
A
R
-
L
A
K
E
V
I
L
L
E
M
N
\
2
5
3
0
3
C
I
V
I
L
-
S
U
R
V
E
Y
\
S
U
R
V
E
Y
P
R
O
D
U
C
T
I
O
N
D
R
A
W
I
N
G
S
\
L
O
T
C
E
R
T
S
\
B
L
O
C
K
5
\
L
O
T
3
7
\
2
5
3
0
3
L
3
7
B
5
.
D
W
G
1OF
CERTIFICATE
OF SURVEY
1
21-25303
LAKEVILLE MINNESOTA
JW
MAS
LENNAR
CORPORATION
CASLANO
LOT 37, BLOCK 5
I HEREBY CERTIFY THAT THIS SURVEY, PLAN, OR REPORT WAS
PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A
DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF
MINNESOTA.
DATE LIC. NO.12/2/24 45817
MARK A. SCHWANZ
CONSTRUCTION NOTES:
1.Install rock construction entrance.
2.Install silt fence as needed for erosion.
3.Sidewalks shall drain away from house a minimum
of 1%.
4.Contractor must verify driveway design.
5.Contractor must verify service elevation prior to
construction.
6.Add or remove foundation ledge as required.
GENERAL NOTES:
1.Grading plan by ISG last dated May 9, 2022 was
used to determine proposed elevations shown
hereon.
2.This survey does not purport to show
improvements or encroachments, except as shown,
as surveyed by ISG or under my direct supervision.
3.Proposed building dimensions shown are for
horizontal location of structures on the lot only.
Contact builder prior to construction for approved
construction plans.
4.No specific soil investigation has been performed
on this lot by the surveyor. The suitability of soils to
support the specific house proposed is not the
responsibility of the surveyor.
5.If building footprint exceeds the building pad,
additional earthwork and testing will be required to
meet the requirements as outlined within the
geotechnical report.
6.This certificate does not purport to show
easements other than those shown on the recorded
plat.
7.Bearings shown are based on the Final Plat.
8.Site address is 18130 Hounds Drive, Lakeville, MN
55044
9.House/Basement type: Washburn EH05 A3 - Left -
Walkout
10.Building dimensions shown are based on First
Floor Plan.
11.Proposed Contours are shown hereon.
12.Topographic survey was completed on November
26, 2024.
BENCHMARK:
Top nut fire hydrant located in the NE quadrant of
Hideaway Trail and Highview Avenue.
Elevation = 1038.03 feet
AREA TABLE:
House/Garage Area = 2,120 sq. ft.
Porch Area = 158 sq. ft.
Driveway/Walk Area = 915 sq. ft.
Total Impervious Area = 3,193 sq. ft.
Lot Area = 11,844 sq.ft.
Impervious Coverage = 27.0%
HOUSE ELEVATIONS:Proposed/As-Built
Garage Floor = 1047.5
Top of Foundation = 1047.8
Lowest Floor = 1039.8
Lowest Opening = 1039.8
0
SCALE IN FEET
10 20
982
982.5
985.
0
5
LEGEND
Existing Building
Sanitary Line
Water Line
Storm Line
Iron Monument Found
RLS 45817
Cleanout
Curb Stop
Manhole/Catch Basin
Transformer
Utility Pedestal
Water Valve
Fire Hydrant
Offset Iron
Existing Contour
Proposed Contour
Proposed Spot Elevation
Existing Spot Elevation
Surface Drainage Direction
>
>>
I
U
Note: Cut and fill quantities include building
excavation, driveway, and lot grading.
GRADING QUANTITIES (CY)
Calc Common Cut -135
Calc Common Fill 271
Driveway*-24
Basement Slab -37
Contracted Amount -71
Additional Amount -0
Sand -7
Swell 20%54
Total Cut -274
Total Fill 325
Total (±)51