Loading...
HomeMy WebLinkAbout18130 Hounds Dr SurveyHOU N D S D R I V E 37 18130 Hounds Dr 10.34'os bc on line NE 25898 0.00 bc 9.83'os bc on line NE 1045 . 6 0 1046.62 1037.02 10 3 3 . 4 5 1033.50 1033 . 1 8 1046.44 1044 . 4 7 1047 . 2 6 1047 . 6 6 10 4 6 . 7 7 104 6 . 4 2 1045 . 6 7 1045.99 1045 . 2 2 10 4 4 . 5 5 U I I I >> >> >> >> >> >> >> >> >> >> >> >> >> >> >> >> >> > > > > >> >> > > > I I I I PROPOSED WALKOUT PROPOSED GARAGE PROPOSED DRIVEWAY 5.0% SLOPE (to walk) Buildi n g S e t b a c k Drainag e a n d U t i l i t y E a s e m e n t N:178197.02 E:519748.49 I=1032.97 (OTHER" RCP) SUMP SUMP HAS DROP OFF FROM SW PIPE TO E PIPE EX CB T/C=1044.97 EX CB I=1030.53 (24" RCP) SE I=1030.34 (24" RCP) N 1034 . 6 4 1034 . 2 9 EX DROP INTAKE R=1033.14 I=1030.66 I=1 0 4 0 . 4 2 R=1034.00 EX CB I=1028.36 (30" RCP) N I=1028.44 (30" RCP) S I=1029.60 (15" RCP) SW R=1036.38 I=1033.00 (12" PVC) NE I=1033.04 (12" PVC) S S43 ° 1 0 ' 4 6 " E 1 3 5 . 2 5 PORC H N:178306.86 E:519726.42 L=61.88 R=130.00 Δ=27°16'17" 4.00 6.0 4 8.00 21 . 4 6 6.0 0 23.5 4 44. 0 0 L=88.00 R=340.00 Δ=14°49'43" N59° 4 7 ' 5 5 " E 35.5 2 S1 5 ° 5 4 ' 2 9 " E 1 2 5 . 0 4 13.62 12.504.0 06.04 8.0 0 21.46 4.0 0 10.0 0 6.00 23 . 5 4 44.00 25.68 13.77 24.99 44 . 0 0 20 . 4 6 6.0 10.0 2.0 10.04.0 18.5 10 4 6 . 9 5 1044 . 3 3 1038 . 3 6 1041.63 1036 1038 1040 1042 1044 1046 10 4 6 1044 1040 1042 104 6 10 4 8 10 3 8 . 8 0 103 7 . 0 6 104 5 . 5 6 HP 104 5 . 2 9 1047.22 104 7 . 5 0 104 7 . 5 0 104 4 . 6 0 1038.8 0 103 8 . 7 2 1047.07 104 6 . 9 5 10 4 6 . 9 5 1036 . 8 7 1033.7 9 103 4 . 9 9 EOF 10 3 9 . 3 0 1039.307 30 10 10 5 10 25 50 . 4 104 7 . 2 4 HP 20 26 10 3 7 . 2 4 EO F 1047.50 104 4 . 5 0 104 7 . 5 0 14.3 3 12.79 25303 L37 B5 DATE REVISION SCHEDULE DESCRIPTION BY PROJECT NO. CAD FILE NAME DRAWN BY DESIGNED BY ORIGINAL ISSUE DATE CLIENT PROJECT NO. REVIEWED BY PROJECT SHEET TITLE WITHOUT PRIOR WRITTEN CONSENT. INC. AND MAY NOT BE USED, COPIED OR DUPLICATED THIS DOCUMENT IS THE PROPERTY OF I & S GROUP, FI L E L O C A T I O N : S: \ P R O J E C T S \ 2 5 0 0 0 P R O J \ 2 5 3 0 0 - 2 5 3 9 9 \ 2 5 3 0 3 S T R E E F L A N D P R O P E R T Y - L E N N A R - L A K E V I L L E M N \ 2 5 3 0 3 C I V I L - S U R V E Y \ S U R V E Y P R O D U C T I O N D R A W I N G S \ L O T C E R T S \ B L O C K 5 \ L O T 3 7 \ 2 5 3 0 3 L 3 7 B 5 . D W G 1OF CERTIFICATE OF SURVEY 1 21-25303 LAKEVILLE MINNESOTA JW MAS LENNAR CORPORATION CASLANO LOT 37, BLOCK 5 I HEREBY CERTIFY THAT THIS SURVEY, PLAN, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED LAND SURVEYOR UNDER THE LAWS OF THE STATE OF MINNESOTA. DATE LIC. NO.12/2/24 45817 MARK A. SCHWANZ CONSTRUCTION NOTES: 1.Install rock construction entrance. 2.Install silt fence as needed for erosion. 3.Sidewalks shall drain away from house a minimum of 1%. 4.Contractor must verify driveway design. 5.Contractor must verify service elevation prior to construction. 6.Add or remove foundation ledge as required. GENERAL NOTES: 1.Grading plan by ISG last dated May 9, 2022 was used to determine proposed elevations shown hereon. 2.This survey does not purport to show improvements or encroachments, except as shown, as surveyed by ISG or under my direct supervision. 3.Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. 4.No specific soil investigation has been performed on this lot by the surveyor. The suitability of soils to support the specific house proposed is not the responsibility of the surveyor. 5.If building footprint exceeds the building pad, additional earthwork and testing will be required to meet the requirements as outlined within the geotechnical report. 6.This certificate does not purport to show easements other than those shown on the recorded plat. 7.Bearings shown are based on the Final Plat. 8.Site address is 18130 Hounds Drive, Lakeville, MN 55044 9.House/Basement type: Washburn EH05 A3 - Left - Walkout 10.Building dimensions shown are based on First Floor Plan. 11.Proposed Contours are shown hereon. 12.Topographic survey was completed on November 26, 2024. BENCHMARK: Top nut fire hydrant located in the NE quadrant of Hideaway Trail and Highview Avenue. Elevation = 1038.03 feet AREA TABLE: House/Garage Area = 2,120 sq. ft. Porch Area = 158 sq. ft. Driveway/Walk Area = 915 sq. ft. Total Impervious Area = 3,193 sq. ft. Lot Area = 11,844 sq.ft. Impervious Coverage = 27.0% HOUSE ELEVATIONS:Proposed/As-Built Garage Floor = 1047.5 Top of Foundation = 1047.8 Lowest Floor = 1039.8 Lowest Opening = 1039.8 0 SCALE IN FEET 10 20 982 982.5 985. 0 5 LEGEND Existing Building Sanitary Line Water Line Storm Line Iron Monument Found RLS 45817 Cleanout Curb Stop Manhole/Catch Basin Transformer Utility Pedestal Water Valve Fire Hydrant Offset Iron Existing Contour Proposed Contour Proposed Spot Elevation Existing Spot Elevation Surface Drainage Direction > >> I U Note: Cut and fill quantities include building excavation, driveway, and lot grading. GRADING QUANTITIES (CY) Calc Common Cut -135 Calc Common Fill 271 Driveway*-24 Basement Slab -37 Contracted Amount -71 Additional Amount -0 Sand -7 Swell 20%54 Total Cut -274 Total Fill 325 Total (±)51