HomeMy WebLinkAboutItem 06c - Launch Park Fourth Addition1
City of Lakeville
Community Development
Memorandum
To: Planning Commission
Heather Botten, Senior Planner
September 8, 2025
Packet Material for the September 18, 2025 Planning Commission Meeting
: Launch Park Fourth Addition Preliminary Plat
November 27, 2025
BACKGROUND
Lakeville Flexspace, LLC has submitted a preliminary plat for Launch Park Fourth Addition.
The proposed plat includes one lot and one outlot on a 20-acre parcel. Lot 1 is eight acres and
the outlot is 12 acres. Lakeville Flexspace is proposing to construct a garage condo development
on Lot 1. The proposed storage development is a permitted use in the I-2, General Industrial
District. The complex would include three garage condo buildings, each roughly 33,750 square
feet (375’ x 90’) in size and one building about 16,875 square feet (375’ x 40’). Each building
consists of multiple units, and each unit has access to water and sewer.
The property is located east of Cedar Avenue (CSAH 23) and south of future 222nd Street. The
preliminary plat plans have been reviewed by the Engineering Division, Fire Marshal, and
Parks and Recreation Department.
The following exhibits are attached for your information:
A. Location Map
B. Zoning Map
C. Preliminary Plat
D. Site Plan
2
E. Grading Plan
F. Utility Plan
G. Landscape Plan
H. Photometric Plan
I. Building Elevations
The property is zoned I-2, General Industrial District. The
proposed project is surrounded by the following existing or planned land uses:
Commission Property Township Comprehensive
Plan guides for agricultural
Eureka Township
Zoning Map
The property is currently guided Industrial
and located in Planning District No. 6 of the Comprehensive Land Use Plan. The property is
in the Metropolitan Urban Service Area (MUSA) which means that City municipal services,
including sanitary sewer service, are available to serve the property. The property is zoned I-
2, General Industrial District. The proposed lot and outlot meet the minimum lot size and
width requirements for future development in the I-2 district. The proposed preliminary plat
meets the recommended goals and objectives of the zoning code and comprehensive plan.
The site is currently undeveloped; historically used for agricultural
production of row crops.
The parent parcel is platted as Outlot A, Launch Park First Addition. This
was platted as an outlot with the intent of future industrial development. The preliminary plat
of Launch Park Fourth Addition consists of one lot and one outlot. The lots proposed with the
3
preliminary plat exceed the minimum lot area and lot width requirements for the I-2, General
Industrial District.
Right-of-way dedication for 222nd Street was done with previous plats and no
additional right-of-way is needed. 222nd Street is a local rural industrial street constructed as a
40-foot-wide paved section within an 80-foot right of way.
City sanitary sewer and water is currently available to the
site. The existing and planned future City sanitary sewer and water systems available to serve
the area of the preliminary plat are adequate to accommodate the build-out of future industrial
building(s) within the preliminary plat area. Proposed grading, drainage, erosion control, and
utility plans for Launch Park Fourth Addition are shown on the attached civil plans.
Grading, drainage, erosion control, and utility issues are addressed in the engineering review
memo prepared by Jon Nelson, Assistant City Engineer and Mac Cafferty, Environmental
Resources Manager dated September 8, 2025. A copy of the engineering report is attached for
your review. The Engineering Division recommends approval of Launch Park Fourth Addition
preliminary plat subject to the stipulations outlined in the engineering report.
. The Fire Marshal reviewed the plans and stated an onsite hydrant about
midpoint of the property would be required on the east side of the development.
There are no wetlands on the site.
There are no significant trees identified within the preliminary plat.
The City’s Comprehensive Parks, Trails, and Open
Space Plan does not identify any future park needs in the area of the plat and no public trails
or sidewalks are being constructed with this plat. Park dedication will be satisfied by a cash fee
in lieu of land dedication, which is $5,615 per acre for industrial zoned property. Lot 1, Block
1 is 7.98 acres and must pay $44,807.70 for park dedication with Launch Park Fourth Addition
final plat. The park dedication requirement for Outlot A will be paid when platted into lots
and blocks.
4
SITE PLAN REVIEW
The site plan proposes three 33,750 square foot (375’ x 90’) garage condo buildings and one
16,875 square foot (375’ x 40’) building. Site improvements also include access drive aisles,
utilities, and stormwater management facilities. The proposed stormwater treatment involves
an infiltration pond on the east side of the site.
The I-2, Industrial District requires the following setback requirements:
The maximum height of a building in the I-2 zoning district is 50 feet. The
proposed buildings are single level with a mezzanine. The tallest point of the buildings is 31
feet, complying with code requirements.
The buildings are designed with LP Smartside LAP siding (engineered wood)
with accent panels on the corners. On walls that are public-facing, three feet of stone veneer is
added to the bottom of the building. The proposed materials are in compliance with the
requirements for industrial buildings.
There is one access point on 222nd Street. The access complies
with spacing guidelines in the City Code. There is no separate guest parking area proposed.
Section 11-19-13 of City Code requires 3 parking spaces, plus 1 space per 100 storage units. A
revised site plan demonstrating the required parking spaces is required prior to final plat
approval.
Landscaping on the site includes deciduous and coniferous trees planted along
the front property line. Financial security will be required with the final plat to guarantee
installation of the approved landscaping. A revised landscaping plan is required to identify the
tree species and the quantity of each to be planted and must be reviewed and approved by the
City Forester.
If trash will be kept outdoors in an enclosure, the structure must meet the
requirements of Section 11-18-11, including exterior materials, location, and screening. All
outdoor trash enclosures must be screened with a structure that is a minimum of six feet in
height or one foot taller than the containers and must be constructed of materials that match
the architecture of the principal building.
The submitted lighting plan shows that the proposed lighting on site meets the
Zoning Ordinance requirement of light levels not exceeding one foot candle at the property
line along right-of-way. At this time, there are no parking lot lights, only wall mounted lights
that are downward facing LED wall packs.
5
Signs. All signs shall comply with the Zoning Ordinance requirements for the I-2 District. A
sign permit shall be issued prior to the installation of any signs.
Primary mechanical equipment will be contained within the
building. Any exterior equipment shall follow the screening requirements in Section 11-21-13
of city code.
Community Development staff recommend approval of Launch Park Fourth Addition
preliminary plat subject to the following stipulations:
1. Implementation of the recommendations listed in the engineering report dated September
8, 2025 and any subsequent correspondence.
2. The final plat shall be in substantial conformance with the preliminary plans on file with
the Community Development Department except as may be modified by the conditions
herein.
3. A development contract and related agreements shall be approved by the City Council with
the approval of the final plat.
4. The site and building shall be developed in accordance with the plans approved by the City
Council.
5. Landscaping shall be installed consistent with a landscape plan approved by the City
Forester. A financial security shall be submitted with the development contract to
guarantee installation of the approved landscaping. All landscaped areas within and
adjacent to the building and parking lot shall be irrigated. Trees and shrubs shall not be
planted in road right-of-way.
6. The park dedication fee must be paid with the final plat.
7. Site lighting shall not exceed one foot candle at the property line adjacent to public right-
of-way. All exterior light fixtures shall be down-cast design so as not to glare onto public
right-of-way.
8. Section 11-19-13 of City Code requires 3 parking spaces, plus 1 space per 100 storage units.
A revised site plan demonstrating the required parking spaces is required prior to final plat
approval.
9. An onsite hydrant about midpoint of the property shall be required on the east side of the
development as required by the Fire Marshal.
City of Lakeville
Public Works – Engineering Division
Memorandum
To: Heather Botten, Senior Planner
Jon Nelson, Assistant City Engineer
McKenzie L. Cafferty, Environmental Resources Manager
Joe Masiarchin, Parks & Recreation Director
Zach Johnson, City Engineer
Julie Stahl, Finance Director
Dave Mathews, Building Official
Tina Goodroad, Community Development Director
September 8, 2025
Launch Park Fourth Addition
• Preliminary Plat Review
• Preliminary Grading and Erosion Control Plan Review
• Preliminary Landscaping Plan Review
• Preliminary Utility Plan Review
Lakeville Flexspace, LLC representatives have submitted a preliminary plat named Launch
Park Fourth Addition along with preliminary plans to construct a garage condo complex on
one (1) block with one (1) outlot on 20.02 acres. The parent parcel (Outlot A, Launch Park First
Addition) is zoned I-2, General Industrial District.
The proposed development is located east of Cedar Avenue (CSAH 23), south of and adjacent
to 222nd Street, north of 225th Street and Eureka Township, and west of Flagstaff Avenue. The
parent parcel consists of Outlot A, Launch Park.
LLAAUUNNCCHH PPAARRKK FFOOUURRTTHH AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY PPLLAATT
SSEEPPTTEEMMBBEERR 88,, 22002255
PPAAGGEE 22 OOFF 55
The outlots created with the preliminary plat shall have the following use:
Outlot A: Future Development; retained by Developer (12.04 acres)
The proposed development will be completed by:
Developer: Hat Trick Investments, Inc.
Engineer/Surveyor: Auth Consulting & Associates
The existing parcel consists of Outlot A, Launch Park First Addition. The site consists of
undeveloped agricultural land. The site is located within the South Creek Stormwater District
with the site generally draining west to east. The northwest of the site is being used for
stockpiling.
SSTTRREEEETT AANNDD SSUUBBDD II VV II SSIIOO NN LLAAYYOO UUTT
222nd Street
Launch Park Fourth Addition is located south of and adjacent to the extension of 222nd Street
from its existing terminus at the intersection of 222nd Street and Garvey Lane through the
western plat boundary. The roadway is a 40-foot-wide rural roadway terminating in a cul-de-
sac and is actively under construction in association with Airlake DEA final plat.
Construction traffic access and egress for grading, utility, and street construction shall be
limited to a single access from 222nd Street.
The Park Dedication requirement for the parent parcel has not been paid and will be
calculated and satisfied through a cash contribution with the final plat.
Launch Park Fourth Addition is located within the South Creek sanitary sewer district as
identified in the City’s Comprehensive Sanitary Sewer Plan. Wastewater will be conveyed via
existing sanitary sewer to the Empire Treatment Facility via the MCES Elko/New Market
Interceptor monitored by meter M646.
LLAAUUNNCCHH PPAARRKK FFOOUURRTTHH AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY PPLLAATT
SSEEPPTTEEMMBBEERR 88,, 22002255
PPAAGGEE 33 OOFF 55
Launch Park Fourth Addition includes the construction of privately owned and maintained
sanitary sewer. 8-inch sanitary sewer will be connected to the public sanitary sewer stub
located at the property line south of 222nd Street.
The Sanitary Sewer Availability Charge has not been collected on the parent parcel and will
be required with the final plat. The fee will be based on the rate in effect at the time of final
plat approval.
Development of Launch Park Fourth Addition includes the construction of privately owned
and maintained watermain. 6-inch watermain will be connected to the public sanitary sewer
stub located at the property line south of 222nd Street.
Launch Park Fourth Addition is located within the South Creek stormwater district as
identified in the City’s Water Resources Management Plan.
Development of Launch Park Fourth Addition includes the construction of a privately owned
and maintained stormwater management infiltration basin to collect and treat the
stormwater runoff generated from the site. The Developer shall submit an approved final
stormwater management plan for the site prior to approval and recording of the Launch Park
Fourth Addition final plat. The Developer shall submit an approved final grading plan prior to
approval and recording of the Launch Park Fourth Addition final plat and issuance of a
grading permit.
The final grading plan shall identify all fill lots in which the building footings will be placed on
fill material. The grading specifications shall also indicate that all embankments meet
FHA/HUD 79G specifications. The Developer shall certify to the City that all lots with footings
placed on fill material are appropriately constructed. Building Certificate of Occupancies will
not be issued until a soils report and an as-built certified grading plan have been submitted
and approved by City staff.
Launch Park Fourth Addition contains more than one acre of site disturbance. A National
Pollution Discharge Elimination System General Stormwater Permit for construction activity is
required from the Minnesota Pollution Control Agency for areas exceeding one acre being
disturbed by grading. A copy of the Notice of Stormwater Permit Coverage must be
submitted to the City upon receipt from the MPCA.
LLAAUUNNCCHH PPAARRKK FFOOUURRTTHH AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY PPLLAATT
SSEEPPTTEEMMBBEERR 88,, 22002255
PPAAGGEE 44 OOFF 55
SSTTOORRMM SSEEWWEERR
Development of Launch Park Fourth Addition includes the construction of a privately owned
and maintained storm sewer system. Storm sewer will be installed within the subdivision to
collect and convey stormwater runoff to the privately owned and maintained infiltration
basin.
The Storm Sewer Charge has not been collected on the parent parcel and will be required
with the final plat. The fee will be based on the rate in effect at the time of final plat approval.
Final locations and sizes of all storm sewer facilities will be reviewed by City staff with the
building permit application and final construction plans.
Launch Park Fourth Addition is located within areas shown on the Flood Insurance Rate Map
(FIRM) as Zone X, as determined by FEMA (Map number 27037C0214E). Based on this
designation, no areas within the plat are located within a Special Flood Hazard Area (SFHA).
There are no wetlands within the project area.
TTRREEEE PPRREESSEERRVVAATT IIOONN
There are no significant trees identified on the site.
The plant schedule is to be updated to identify the specific tree types and quantity of each to
be planted.
EERROOSSIIOONN CCOONNTTRROOLL
The Developer is responsible for obtaining an MPCA Construction Permit for the site prior to
construction. The developer is responsible for following and implementing all of the
requirements outlined in the SWPPP. Any changes made throughout construction must be
documented in the SWPPP. Additional erosion control measures may be required during
construction as deemed necessary by City staff. Any additional measures required shall be
installed and maintained by the Developer.
LLAAUUNNCCHH PPAARRKK FFOOUURRTTHH AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY PPLLAATT
SSEEPPTTEEMMBBEERR 88,, 22002255
PPAAGGEE 55 OOFF 55
RREECCOOMMMMEENNDDAATTIIOONN
Engineering recommends approval of the Launch Park Fourth Addition preliminary plat,
preliminary erosion control plan and grading plan, preliminary utility plan, and preliminary
landscape plan subject to the requirements and stipulations within this report.
Dakota County, Maxar
City of Lakeville
Location Map
Launch Park
Fourth Add
Preliminary Plat
EXHIBIT A
Site Location
CE
D
A
R
A
V
E
(
C
S
A
H
2
3
)
220TH ST
Eureka Township
GA
R
V
E
Y
L
N
225TH ST
Ci
t
y
o
f
F
a
r
m
i
n
g
t
o
n
Ai
r
l
a
k
e
A
i
r
p
o
r
t
±
I-3
I-2
I-2
I-2I-3 I-2
City of Lakeville
Zoning Map
Launch Park
Fourth Add
Preliminary Plat
EXHIBIT B
Site Location
CE
D
A
R
A
V
E
(
C
S
A
H
2
3
)
220TH ST
Eureka Township
GA
R
V
E
Y
L
N
Ci
t
y
o
f
F
a
r
m
i
n
g
t
o
n
Ai
r
l
a
k
e
A
i
r
p
o
r
t
±
I-3
I-3
I-2
222ND STREET WEST
NO BUILDING OBSERVED
LOT 1
OUTLOT A
BLOCK 1
REVISIONSPAGE
DRAWING NAME:
JOB NO.
FILE NO.
FIELD BOOK SURVEY FOR:PROPERTY ADDRESS:
DRAWN BY:
BY:
CHECKED
FIELDWORK
CHIEF:
EXISTING LEGAL DESCRIPTION:
GENERAL SURVEY NOTES:
PRELIMINARY PLAT FOR:
WWW.EFNSURVEY.COM
New Brighton, Minnesota 55112
PHONE: (612) 466-3300
475 Old Highway 8 NW, Suite 200
Egan, Field & Nowak, Inc.
l a n d s u r v e y o r s s i n c e 1 8 7 2
LEGEND:GOPHER STATE ONE CALL NOTE:
222nd Street W & Garvey Lane
Lakeville, Minnesota 55024
Dakota County Tax PID 224450500010
Kimley Horn & Associates, Inc.
Kimley Horn & Associates, Inc.
PAGE
DRAWING NAME:
JOB NO.
FILE NO.
FIELD BOOK
DRAWN BY:
BY:
CHECKED
FIELDWORK
CHIEF:
N
SHEET 1 OF 1
CERTIFICATION:
PROPOSED LOT SUMMARY:
PROPOSED LEGAL DESCRIPTIONS:
PRELIMINARY PLAT OF
LAUNCH PARK FOURTH ADDITION
OWNER/SUBDIVIDER:
LAND SURVEYOR:
CIVIL ENGINEER:
3
2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 2 2 2 2
2 2 2 2 2 2 2 2 2
2 2 2 2 2
2 2 2 2 2 2 2 2 2 2
2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 2 2 2 2 2 2 2 2 2 2 2 2 2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
1
1
1 1
1
1
1
1
1
1
1 1
1
1
1
1
1
1
1 1
1
1
1
1
1
1
1 1
1
1
1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
4 4
4
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5
11
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
10
10
8
8
8
2' OVERHANG
2' OVERHANG
2' OVERHANG
2' OVERHANG
2' OVERHANG
2' OVERHANG
2' OVERHANG
2' OVERHANG
2' OVERHANG
2' OVERHANG
2' OVERHANG
2' OVERHANG
2' OVERHANG
2' OVERHANG
WATER SERVICE
RISER ROOM
WATER SERVICE
RISER ROOM
WATER SERVICE
RISER ROOM
WATER SERVICE
RISER ROOM
MATCH STREET
(UNDER CONSTRUCTION)
BUILDING SETBACK
BUILDING SETBACK
BUILDING SETBACK
BU
I
L
D
I
N
G
S
E
T
B
A
C
K
BU
I
L
D
I
N
G
S
E
T
B
A
C
K
BU
I
L
D
I
N
G
S
E
T
B
A
C
K
BU
I
L
D
I
N
G
S
E
T
B
A
C
K
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE PROPERTY LINE
DRAINAGE EASEMENT
DRAINAGE EASEMENT
222ND STREET WEST
30' WIDE DRAINAGE SWAL
E
(UNDER CONSTRUCTION)
6
6
6
6
6
6
6
6
6
6
(UNDER CONSTRUCTION
)
1
2
4
5
3
SHEET KEY
6
NEW BUILDING OVERHEAD DOOR
30" CONCRETE APRON
BITUMINOUS PAVEMENT
24" CONCRETE VALLEY GUTTER
7
24" CONCRETE SURMOUNTABLE CURB & GUTTER
8
RESERVED
9 STORM INLET/MANHOLE
10 STORMWATER MANAGEMENT BASIN
11 24" CONCRETE RIBBON CURB
NEW BUILDING ENTRANCE/EXIT DOOR
DRAINAGE SWALE
LEGEND
BUILDING SETBACK
PROPOSED BITUMINOUS
PROPOSED CONCRETE SURFACE
PROPOSED BUILDING PROPOSED STORM WATER
MANAGEMENT AREA
DRAINAGE SWALE
24" RIBBON CURB
24" VALLEY GUTTER
GENERAL SITE NOTES
1.CONTRACTOR TO OBTAIN PERMISSION/PERMIT FROM THE CITY TO WORK IN
RIGHT-OF-WAY PRIOR TO ANY WORK BEING PERFORMED WITHIN THE PUBLIC
RIGHT-OF-WAY. ANY REQUIRED LANE CLOSURES OR TRAFFIC CONTROL
SIGNAGE/DETOUR PLANS IS THE RESPONSIBILITY OF THE CONTRACTOR AND
SHALL BE COORDINATED WITH CITY STAFF, AS REQUIRED.
2.CONTRACTOR TO FIELD VERIFY AND LOCATE ALL EXISTING UTILITIES PRIOR TO
CONSTRUCTION.
3.CONTRACTOR TO COORDINATE RELOCATION OF ANY SMALL UTILITIES, AS
NECESSARY.
4.CONTRACTOR SHALL MAINTAIN TRAFFIC ACCESSIBILITY ALONG THE PROJECT.
5.NO TREES OR SHRUBS ARE TO BE REMOVED WITHOUT THE PRIOR APPROVAL
OF THE OWNER.
6.ALL SIGNAGE SHALL BE IN ACCORDANCE TO THE CURRENT EDITION OF THE
MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND
HIGHWAYS AND MnDOT REQUIREMENTS.
24" SURMOUNTABLE CURB & GUTTER
EX. STORM WATER UTILITY EASEMENT
PROPOSED LOT AREA
7.985 ACRES
PROPOSED LOT WIDTH
515.0'
CURRENT ZONING
I2 - GENERAL INDUSTRIAL DISTRICT
SETBACK REQUIREMENTS
FRONT YARD SETBACK - 40'
REAR YARD SETBACK - 30', OR 50' ON THE
YARD ABUTTING RESIDENTIAL ZONED
PROPERTY
SIDE YARD SETBACK - 10' ON ANY 1 SIDE, OR 30'
ON THE SIDE YARD ABUTTING A STREET;
EXCEPT 50' ON THE SIDE YARD BUTTING
RESIDENTIAL ZONED PROPERTY
SITE DATA
PROPERTY BOUNDARY LINE
EXISTING STORMWATER BASIN
DRAINAGE & UTILITY EASEMENT
942
943
943
943
943
943
943
943
943
942
943
943
943
943
943
943
943
943
943
941
941
942
943
943
93
8
942
942
943
93
7
93
8
93
9
INFILTRATION BASIN A
BOTTOM ELEV=935.00
TEMPORARY SEDIMENT BASIN
10 YR HWL = 938.42
100 YR HWL = 940.24
TOTAL VOL. PROVIDED=43,501 CF
WQV REQUIRED = 28,205 CF
WQV ELEV. = 936.50
TOP ELEV=941.00
BUILDING #1
F.F.E. = 943.50
F.F.E. = 943.50
BUILDING #2
BUILDING #3
F.F.E. = 943.50
F.F.E. = 943.50
BUILDING #4
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
PROPERTY LINE/R.O.W.
& UTILITY EASEMENT
50' WIDE DRAINAGE
GRADING
LIMITS
(APPROX.)
GRADING
LIMITS
(APPROX.)
GRADING
LIMITS
(APPROX.)
GRADING
LIMITS
(APPROX.)
GRADING
LIMITS
(APPROX.)
GRADING
LIMITS
(APPROX.)
GRADING
LIMITS
(APPROX.)
GRADING
LIMITS
(APPROX.)
BASIN OUTLET
STRUCTURE
(SEE DETAILS)
CREST = 940.00
OUTFALL
STORM SEWER
OUTFALL
STORM SEWER
OUTFALL
STORM SEWER
OUTFALL
STORM SEWER
BASIN OUTLET
STORM WATER
5FT WIDE
BOTTOM
SWALE5FT WIDE
BOTTOM
SWALE
222ND STREET WEST
30' WIDE DRAINAGE SWAL
E
(UNDER CONSTRUCTION
)
CONSTRUCT 1FT WIDE BERM
(UNDER CONSTRUCTION)
20' WIDE WEIR
TOP ELEV.=942.40
F.F.E.=943.50
943.45
H.P./EOF
942.50
94
3
.
3
3
94
3
.
3
3
94
3
.
3
3
2.0%
942
.
7
7
H.P
.
0.
5
%
942
.
5
5
0.
5
%
2.9%
94
3
.
3
3
94
3
.
3
3
94
3
.
3
3
2.0%
942
.
7
7
H.P
.
0.
5
%
0.
5
%
3.
2
%
0.5%
0.5%
L.P./RIM=
942.13
0.5%
0.5%
0.5%
0.5%
L.P./RIM=
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
L.P./RIM=
942.13
F.F.E.=943.50
943.45
4.
6
%
3.
2
%
H.P./EOF
942.50
3.
2
%
4.
6
%
3.
2
%
4.
6
%
3.
2
%
4.
6
%
3.
2
%
H.P./EOF
942.50
F.F.E.=943.50
943.45F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
H.P./EOF
942.50L.P./RIM=
942.13
4.
6
%
3.
2
%
H.P./EOF
942.50
3.
2
%
4.
6
%
3.
2
%
3.
2
%
4.
6
%
3.
2
%
0.5%
L.P./RIM=
942.13
0.5%
0.5%
0.5%
94
3
.
3
3
94
3
.
3
3
94
3
.
3
3
2.0%942
.
7
7
0.
5
%
942
.
5
5
2.9%
L.P./RIM=
942.03
1.0%
1.
3
%
H.P
.
942
.
5
5
0.
5
%
2.9%
94
3
.
3
3
3.
2
%
H.P./EOF
942.50
3.
2
%
0.5%
0.5%
L.P./RIM=
942.13
0.5%
0.5%
0.5%
H.P./EOF
H.P./EOF
942.500.5%
0.5%
2.
3
%
1.
5
%
H.P./EOF
942.500.5%
0.5%
942.06
RIM=
2.
2
%
941.68
RIM=
93
9
.
5
8
939.88
93
9
.
3
4
0.5%
0.5%
939.61939.76
1.
4
%
1.
0
%
1.0%
94
1
.
1
0
94
0
.
8
6
943.00
F.F.E.=943.50
943.00
F.F.E.=943.50
F.F.E.=943.50
F.F.E.=943.50
F.F.E.=943.50 943.00
F.F.E.=943.50
933.93
INV=933.54
INV=
0.5%
0.5%
L.P./RIM=
4.
1
%
942.25
4.
1
%
1.
7
%
941.91
942
.
7
7
0.
5
%
942
.
5
5
2.9%
4.
1
%
942.25
4.
1
%
1.
7
%
1.
7
%
941.91
942
.
5
5
2.9%
941.91
1.
7
%
942
.
5
5
2.9%
4.
1
%
942.25
1.
7
%
942
.
5
5
2.9%
4.
1
%
940.03
2.
6
%
942.50L.P./RIM=
942.13
4.
6
%
3.
2
%
H.P./EOF
942.50
3.
2
%
4.
6
%
3.
2
%
4.
6
%
3.
2
%
4.
6
%
3.
2
%
H.P./EOF
942.50
94
3
.
3
3
94
3
.
3
3
2.0%942
.
7
7
0.
5
%
942
.
5
5
2.9%
H.P
.
942
.
5
5
0.
5
%
2.9%
94
3
.
3
3
94
3
.
3
3
94
3
.
3
3
2.0%942
.
7
7
0.
5
%
942
.
5
5
2.9%
H.P
.
942
.
5
5
0.
5
%
2.9%
1.
3
%
L.P./RIM=
942.03
1.0%
1.
3
%
1.
3
%
L.P./RIM=
942.03
1.0%
1.
3
%
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
943.45F.F.E.=943.50
943.45
F.F.E.=943.50
943.45F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
943.45F.F.E.=943.50
943.45
F.F.E.=943.50
943.45F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
F.F.E.=943.50
F.F.E.=943.50
F.F.E.=943.50
943.45
F.F.E.=943.50
943.45
4.
0
%
1.0%
1.
7
%
94
3
.
3
3
94
3
.
3
3
94
3
.
3
3
2.0%
H.P
.
0.
5
%
942
.
5
5
2.9%
942.26
941.93
L.P./RIM=
0.
7
%
942.80943.00
943.00
943.00
942.80
942.80
942.80
942.80
942.00
941.25
940.50
940.13
L.P./RIM=
1.
5
%
941.93
L.P./RIM=
0.5%
CONSTRUCT TEMPORARY SEDIMENT BASIN TO
PROVIDE LIVE STORAGE VOLUME GREATER
THAN OR EQUAL TO 27,000 CF. REFER TO
SWPPP FOR ADDITIONAL INFORMATION.
93
6
93
6
93
7
93
7
93
7
93
7
93
8
93
8
93
8
93
8
93
9
93
9
93
9
93
9
94
0
94
0
94
0
94
0
94
1
94
1
94
1
94
1
94
2
94
2
94
2
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
945
935
93
5
93
5
93
5
935
93
5
93
5
940
94
0
94
0
940
94
0
94
0
94
0
LEGEND
EXISTING 5FT CONTOURS
EXISTING 1FT CONTOURS
APPROXIMATE GRADING LIMITS
PROPOSED BUILDINGS
PROPOSED 5FT CONTOURS
PROPOSED 1FT CONTOURS H.P.= HIGH POINT GRADE ELEVATION
= LOW POINT GRADE ELEVATION
FFE = FINISHED FLOOR ELEVATION
PROPOSED FINISHED GRADE
SURFACE DRAINAGE
L.P.
XXX.XX
(ALL CURB SPOT ELEVATION SHOWN ARE AT
CURB FLOWLINE UNLESS OTHERWISE NOTED)
PROPOSED FINISHED GRADE SPOT ELEVATIONS
BENCHMARK
X.X%
1.REFER TO SHEET C1.1 - "GENERAL NOTES" FOR GRADING
NOTES.
GRADING NOTES
EOF = EMERGENCY OVERFLOW
TEMPORARY SEDIMENT BASIN
(APPROXIMATE)
PROPERTY BOUNDARY LINE
>
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
>
>
>
>
STM STM STM STM STM
STM STM STM STM STM STM STM
STM STM STM STM STM STM STM
STM STM STM STM STM
STM STM STM STM STM STM STM
STM STM STM STM STM STM STM
STM STM STM STM STM
STM STM STM STM STM STM STM
STM STM STM STM STM STM STM
STM
STM STM STM
STM STM STM STM STM STM STM STM STM
STM STM STM STM STM STM STM STM
ST
M
ST
M
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
STM
STM
222ND STREET WEST
30' WIDE DRAINAGE SWAL
E
(UNDER CONSTRUCTION)
(UNDER CONSTRUCTION)
I(24")=933.93
W/ TRASHGUARD
STM F.E.S. #E2
24" RCP F.E.S.
STM F.E.S. #E1
I(24")=933.54
24" RCP F.E.S.
78'-24" RCP @ 0.5%
STM INLET #C5
STM INLET #B5
(2'x3' BOX)
NEENAH R-3067-V CASTING
D = 3.00'
R = 941.93
I(12"E) = 938.93
STM INLET #A5
D = 3.82'
I(12"W) = 938.21
R = 941.93
I(15"E) = 938.11
NEENAH R-3067-V CASTING
STM INLET #A4
STM INLET #B4
STM INLET #B3
STM INLET #C3
STM INLET #C4
(4' DIAM. MH)
180'-12" RCP(CL5) @ 0.4%
(2'x3' BOX)
NEENAH R-3067-V CASTING
D = 2.75'
R = 942.03
I(12"E) = 939.28
100'-12" RCP(CL5) @ 0.4%
150'-15" RCP(CL5) @ 0.4%
(4' DIAM. MH)
D = 3.35'
I(12"W) = 938.88
R = 942.13
I(15"E) = 938.78
NEENAH R-2540 CASTING
(4' DIAM. MH)
D = 4.05'
I(15"W) = 938.18
R = 942.13
I(18"E) = 938.08
NEENAH R-2540 CASTING
100'-12" RCP(CL5) @ 0.4%
150'-15" RCP(CL5) @ 0.4%
(2'x3' BOX)
NEENAH R-3067-V CASTING
D = 2.75'
R = 942.03
I(12"E) = 939.28
(4' DIAM. MH)
D = 3.35'
I(12"W) = 938.88
R = 942.13
I(15"E) = 938.78
NEENAH R-2540 CASTING
(4' DIAM. MH)
D = 4.05'
I(15"W) = 938.18
R = 942.13
I(18"E) = 938.08
NEENAH R-2540 CASTING
NEENAH R-3067-V CASTING
SAFL BAFFLE )
NEENAH R-3067-V CASTING
(5' DIAM. MH W/
I(18"W) = 937.47
R = 941.91
I(18"E) = 937.37
SAFL BAFFLE )
NEENAH R-3067-V CASTING
D = 9.54'
SUMP(5') = 932.37
D = 9.59'
NEENAH R-3067-V CASTING
I(18")=936.00
STM OUTFALL #B1
18" RCP F.E.S.
I(18")=936.00
STM OUTFALL #C1
18" RCP F.E.S.
I(18")=936.00
STM OUTFALL #D1
18" RCP F.E.S.(2'x3' BOX)
NEENAH R-3067-V CASTING
D = 2.75'
R = 942.03
I(12"E) = 939.28
STM INLET #D5
(4' DIAM. MH)
D = 4.05'
I(15"W) = 938.18
R = 942.13
I(18"E) = 938.08
NEENAH R-2540 CASTING
STM INLET #D3
(4' DIAM. MH)
D = 3.35'
I(12"W) = 938.88
R = 942.13
I(15"E) = 938.78
NEENAH R-2540 CASTING
STM INLET #D4
100'-12" RCP(CL5) @ 0.4%
150'-15" RCP(CL5) @ 0.4%
153'-18" STM @ 0.4%
24'-18" STM @ 5.8%
R = 941.91
SAFL BAFFLE )
STM INLET #B2
STM INLET #C2
STM INLET #D2
(6' DIAM. MH W/
(6' DIAM. MH W/
SUMP(6') = 931.37
D = 10.54'
I(18"E) = 937.37
I(18"W) = 937.47
23'-18" STM @ 6.0%
D = 10.54'
SUMP(6') = 931.37
I(18"E) = 937.37
I(18"W) = 937.47
R = 941.91
23'-18" STM @ 6.0%
154'-18" STM @ 0.4%
154'-18" STM @ 0.4%
37'-
1
8
"
S
T
M
I(15"W) = 937.49
R = 942.06
I(18"E) = 937.39
NEENAH R-3067-V CASTING
STM INLET #A3
(4' DIAM. MH)
(5' DIAM. MH W/
I(18"NW) = 937.19
R = 941.68
SAFL BAFFLE )
I(18"SE) = 937.09
SUMP(5') = 932.09
I(18")=936.00
18" RCP F.E.S.
STM INLET #A2
STM OUTFALL #A1
154'-15" RCP(CL5) @ 0.4%
50'-18" S
T
M
@ 0.4%
D = 4.67'
@ 3
.
0
%
STM STRUCTURE #F
(SEE DETAILS)
STM OUTFALL #F1
12" RCP F.E.S.
I(12")=933.28
BUILDING #1 -WTR SERVIC
E
10' - 4" WTR SERV. W/
6"x6"x4" TEE & 4" G.V.
BUILDING #2 -WTR SERVIC
E
10' - 4" WTR SERV. W/
6"x6"x4" TEE & 4" G.V.
BUILDING #3 -WTR SERVIC
E
10' - 4" WTR SERV. W/
6"x6"x4" TEE & 4" G.V.
BUILDING #4 -WTR SERVIC
E
55' - 4" WTR SERV. W/ 4" G.
V
.
12" WTR STUB.
CONNECT TO EXISTING
& 6" GATE VALVE
INSTALL 12"x6" REDUCER
24°
24°
58
9
'
-
6
"
W
T
R
(SEE DETAILS)
F.G. = 943.30
19.0' - 6" LEAD
6"x6" TEE W/
WITH VALVE
HYDRANT #1
(2)45°
6"x4" REDUCER
14'-8" STM @ 17.9%
INV(8"E)=941.50
INV(8"W)=939.00
BUILDING #1 -SAN. SERVIC
E
22'-6" PVC @ 2.0%(MIN.)
W/ 8"x8"x6" WYE
BUILDING #2 -SAN. SERVIC
E
22'-6" PVC @ 2.0%(MIN.)
W/ 8"x8"x6" WYE
BUILDING #3 -SAN. SERVIC
E
22'-6" PVC @ 2.0%(MIN.)
W/ 8"x8"x6" WYE
BUILDING #4 -SAN. SERVIC
E
45-6" PVC @ 2.0%(MIN.)
W/ 8"x8"x6" WYE & (3) 45°BE
N
D
INV (8")=930.10
8" PVC SANITARY STUB
CONNECT TO EXISTING
62
'
-
8
"
P
V
C
(S
D
R
3
5
)
@ 0
.
5
%
DEPTH=11.03'
INV OUT(8"NE)=930.41
RIM=941.44
SAN MH A1
INV IN(8"S)=930.51
RIM=942.91
SAN MH A2
RIM=942.60
SAN MH A3
DEPTH=9.36'
INV OUT(8"N)=933.24
27
0
'
-
8
"
P
V
C
(
S
D
R
3
5
)
@
0
.
5
%
DEPTH=11.12'
INV OUT(8"N)=931.79
INV IN(8"S)=931.89
25
6
'
-
8
"
P
V
C
(
S
D
R
3
5
)
@
0
.
5
%
LEGEND
PROPOSED BUILDINGS
PROPOSED STORM SEWER
PROPOSED SANITARY SEWER
PROPOSED WATER MAIN
EXISTING STORM SEWER
EXISTING SANITARY SEWER
EXISTING HYDRANT AND VALVE
EXISTING CATCH BASIN
EXISTING SANITARY SEWER
EXISTING WATERMAIN
EXISTING OVERHEAD ELECTRIC LINE
EXISTING POWER POLE
EXISTING UNDERGROUND GAS LINE
PROPOSED INSULATION
EXISTING ELECTRIC LINE
EXISTING TELEPHONE LINE
STORM WATER UTILITY EASEMENT
1.REFER TO SHEET C1.1 - "GENERAL NOTES" FOR GENERAL
UTILITY, SANITARY SEWER, WATER AND STORM SEWER
NOTES.
UTILITY NOTES
PROPERTY BOUNDARY LINE
942
943
943
943
943
943
943
943
943
942
943
943
943
943
943
943
943
943
943
941
941
942
943
943
93
8
942
942
943
BUILDING #1
BUILDING #2
BUILDING #3
BUILDING #4
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
PROPERTY LINE/R.O.W.
222ND STREET WEST
30' WIDE DRAINAGE SWAL
E
(UNDER CONSTRUCTION)
& UTILITY EASEMENT
50' WIDE DRAINAGE
93
7
93
8
93
9
93
6
93
6
93
7
93
7
93
7
93
7
93
8
93
8
93
8
93
8
93
9
93
9
93
9
93
9
94
0
94
0
94
0
94
0
94
1
94
1
94
1
94
1
94
2
94
2
94
2
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
94
3
945
935
93
5
93
5
93
5
935
93
5
93
5
940
94
0
94
0
940
94
0
94
0
94
0
E D D E E D D E E D E D D D E
LEGEND
PLANTSYMBOL
LANDSCAPE PLANTING SCHEDULE
INSTALLATION SIZE
(MINIMUM)CATEGORY
DECIDUOUS TREE
CHOSE VARIETIES
FROM THE PLANT
LIST TO THE RIGHT
AUTUMN BLAZE MAPLE,
NORTHWOOD MAPLE,
NORTHERN PIN OAK,
NORTHERN RED OAK,
SWAMP WHITE OAK,
RIVER BIRCH,
SENTRY LINDEN,
LITTLE LEAF LINDEN,
HACKBERRY,
THORNLESS HONEYLOCUST,
SKYLINE HONEYLOCUST,
KENTUCKY COFFEE TREE
DECIDUOUS SHADE TREES:
2 1
2 INCH DIAMETER
QUANTITY
8
DECIDUOUS ORNAMENTAL TREES:
2 INCH DIAMETER SINGLE STEM
OR 6-7 FOOT, CLUMP FORM
EVERGREEN TREES:
6 FEET IN HEIGHT
NTS
DECIDUOUS TREE PLANTING DETAIL
N.T.S.
EVERGREEN PLANTING DETAIL
SEED w/ MNDOT SOUTHERN
BOULEVARD (SB) SEED MIX (TYP.)
SEED w/ MNDOT WET DITCH (WD)
SEED MIX (TYP.)
SCREENING TREE
(EVERGREEN)
SCREENING TREE
(DECIDUOUS)
EVERGREEN TREE
CHOSE VARIETIES
FROM THE PLANT
LIST TO THE RIGHT
COLORADO BLUE SPRUCE,
BLACK HILLS SPRUCE
7
D
E
E
D
222ND STREET WEST
(UNDER CONSTRUCTION)
0.1
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.2
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.4
0.6
0.6
0.4
0.2
0.1
0.1
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.1
0.2
0.2
0.2
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.3
0.6
0.7
0.5
0.2
0.1
0.2
0.2
0.2
0.2
0.3
0.2
0.4
1.0
1.7
1.5
0.7
0.3
0.3
0.4
0.2
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.1
0.1
0.2
0.3
0.3
0.2
0.2
0.1
0.1
0.2
0.1
0.1
0.3
0.7
1.0
0.7
0.4
0.2
0.2
0.2
0.2
0.2
0.3
0.1
0.3
0.8
1.9
2.3
1.1
0.4
0.1
0.5
0.4
0.3
0.5
0.8
0.1
0.4
1.4
3.1
2.6
0.9
0.2
0.1
1.4
0.6
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.1
0.1
0.3
0.8
1.4
1.1
0.6
0.4
0.3
0.2
0.3
0.4
0.2
0.6
1.6
2.9
1.8
0.6
0.2
0.6
0.6
0.3
0.5
1.0
0.1
0.2
0.9
2.8
3.8
1.4
2.1
1.1
0.5
1.2
3.1
4.3
1.2
0.2
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.1
0.2
0.5
1.7
3.5
2.4
0.8
1.1
0.6
0.4
1.0
1.5
0.1
0.5
1.8
2.8
1.9
0.7
0.8
2.8
4.6
6.3
2.3
0.7
1.8
5.8
5.0
1.6
0.3
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
3.3
1.2
0.6
2.1
5.5
7.0
3.8
1.0
1.1
4.0
6.7
6.2
2.7
0.8
1.8
5.3
5.8
1.7
0.3
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
5.6
1.8
0.8
2.6
6.4
6.1
4.1
1.2
1.1
3.8
7.2
6.9
2.8
0.9
1.5
4.3
3.7
1.6
0.4
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
6.0
2.1
0.8
2.4
6.7
4.0
1.3
0.9
2.9
4.6
3.7
2.4
0.9
1.3
3.2
5.3
2.0
0.4
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
4.8
2.0
0.8
1.9
3.9
3.2
1.3
0.9
2.6
4.5
6.5
3.3
1.0
1.4
4.6
6.2
2.4
0.5
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
4.2
2.1
0.8
1.8
4.7
5.2
1.6
0.9
3.1
7.2
6.4
3.7
1.1
1.3
4.2
6.3
6.9
2.6
0.5
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
6.9
2.7
0.9
2.0
5.8
5.2
1.8
0.9
2.9
6.6
7.2
4.0
1.2
1.1
3.7
6.2
4.4
2.2
0.5
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
6.5
2.9
0.9
1.8
5.5
5.5
1.8
0.8
2.4
5.4
3.7
3.0
1.2
1.0
2.7
3.7
5.0
2.6
0.6
0.2
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
6.0
2.8
0.9
1.5
3.9
3.5
1.7
0.8
2.0
4.0
4.1
1.4
1.0
3.4
7.1
7.0
3.3
0.7
0.2
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
3.8
2.6
0.9
1.4
3.6
6.0
2.2
0.8
2.3
6.5
4.8
1.6
1.0
3.3
6.4
7.1
3.6
0.8
0.2
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
7.2
3.6
1.1
1.4
4.7
6.0
2.5
0.9
2.2
5.8
5.3
1.7
0.9
2.9
6.8
5.0
3.0
0.8
0.2
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
6.3
3.9
1.2
1.3
4.4
6.7
6.8
2.6
0.9
1.8
5.1
3.7
1.6
0.8
2.2
3.7
4.2
3.1
0.9
0.2
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
6.6
3.9
1.2
1.1
3.4
5.1
3.9
2.2
0.8
1.5
3.4
4.6
1.8
0.8
2.4
6.3
6.9
4.4
1.1
0.2
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
3.3
3.0
1.2
1.0
2.8
4.2
6.0
2.8
0.9
1.6
5.1
6.0
2.2
0.9
2.5
6.1
4.6
1.3
0.3
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
4.6
1.4
1.0
3.5
7.4
6.6
3.3
1.0
1.5
4.7
6.4
2.3
0.8
2.2
6.4
4.1
1.2
0.3
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
4.8
1.6
1.0
3.3
6.6
7.3
3.6
1.0
1.4
4.4
4.6
2.1
0.8
1.7
3.7
3.4
1.3
0.3
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
5.2
1.7
0.9
2.8
6.0
4.2
2.8
1.0
1.1
2.9
3.4
4.5
2.3
0.8
1.7
4.9
5.6
1.7
0.3
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
3.4
1.6
0.8
2.2
3.9
5.0
3.5
1.2
1.1
3.8
6.7
7.0
2.9
0.9
1.8
5.3
5.4
1.9
0.4
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
5.4
1.9
0.9
2.6
6.8
6.6
4.4
1.3
1.1
3.7
6.4
6.7
3.2
1.0
1.7
5.3
5.5
1.9
0.4
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
5.8
2.2
0.9
2.5
6.1
4.7
1.4
1.0
3.5
7.2
5.7
2.9
1.0
1.3
3.5
3.8
1.8
0.4
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
6.6
2.4
0.9
2.2
6.0
3.7
1.4
0.9
2.5
3.8
4.1
2.8
1.0
1.3
3.7
6.6
2.4
0.5
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
4.1
2.1
0.8
1.7
3.6
4.0
1.6
0.9
2.7
6.2
7.3
4.0
1.1
1.3
4.2
6.6
6.2
2.6
0.5
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
5.6
2.6
0.9
1.8
5.5
5.7
1.9
0.9
2.8
6.4
6.3
4.1
1.2
1.2
4.0
7.1
6.7
2.7
0.6
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
6.7
3.0
0.9
1.8
5.1
5.7
2.0
0.8
2.6
6.8
3.9
1.2
1.0
3.0
4.6
3.7
2.3
0.6
0.2
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
7.2
3.2
1.0
1.6
5.1
4.7
1.9
0.8
2.0
4.0
3.1
1.2
0.9
2.7
4.7
6.6
3.1
0.7
0.2
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
4.5
2.6
0.9
1.3
3.1
4.1
1.9
0.8
1.9
4.9
5.0
1.5
0.9
3.2
7.2
6.3
3.4
0.8
0.2
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
4.9
3.0
1.0
1.3
4.1
6.7
2.5
0.8
2.0
5.8
4.9
1.6
0.8
2.9
6.7
7.0
3.5
0.7
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
7.0
3.9
1.1
1.2
4.2
6.2
6.3
2.6
0.8
1.8
5.6
4.9
1.4
0.6
2.0
4.6
2.6
1.7
0.5
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
6.6
4.1
1.1
1.0
3.8
7.0
5.5
2.1
0.6
1.1
3.0
1.8
0.8
0.4
0.8
1.1
0.1
0.5
1.5
3.0
2.3
0.9
0.3
0.5
0.6
0.2
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
4.4
2.9
0.8
0.6
1.9
2.7
1.9
0.5
0.1
1.5
0.9
0.4
0.5
0.8
0.1
0.3
1.0
2.6
3.0
1.2
0.4
0.1
0.5
0.3
0.2
0.3
0.3
0.2
0.4
0.9
1.4
1.2
0.6
0.2
0.1
0.2
0.1
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.1
0.5
2.0
4.0
2.3
0.7
1.1
0.5
0.3
0.6
0.5
0.2
0.6
1.7
2.8
1.6
0.6
0.2
0.4
0.3
0.2
0.2
0.2
0.1
0.2
0.5
1.0
1.1
0.6
0.3
0.1
0.2
0.2
0.1
0.1
0.1
0.1
0.2
0.3
0.4
0.4
0.2
0.1
0.1
0.1
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.1
0.2
0.5
1.3
2.1
1.4
0.6
0.5
0.3
0.2
0.2
0.2
0.2
0.4
0.7
0.9
0.6
0.3
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.3
0.2
0.2
0.1
0.0
0.1
0.1
0.1
0.1
0.1
0.0
0.1
0.1
0.1
0.1
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.1
0.1
0.3
0.5
0.6
0.5
0.2
0.2
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.2
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.0
0.0
0.0
0.1
0.1
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
·
·
NON-PUBLIC FACING SIDEWALL
PUBLIC FACING SIDEWALL
PUBLIC FACING ENDWALL PUBLIC FACING ENDWALL
Lakeville FlexSpace Facility | Exterior Rendering- Public Facing
Lakeville, MN | 07/09/2025 | V1 Public Face
1 2
BOULDER AVE & HWY 3
1
MIDWESTFlexSpace
Stone/Faux Stone Wainscot Cement Bd Siding
(Horizontal)
2