Loading...
HomeMy WebLinkAboutItem 05b - North Creek Second AdditionCity of Lakeville Community Development Planning Commission Kris Jenson, Planning Manager November 24, 2025 Packet Material for the December 4, 2025 Planning Commission Meeting North Creek Second Addition preliminary plat. December 16, 2025 KJ Walk, Inc. has applied for a preliminary plat to allow the development plat of 26 single family residential lots and 27 detached townhome lots on 13.35 acres to be known as North Creek Second Addition. The preliminary plat is located east of Pilot Knob Road (CSAH 31) and south of 173rd Street. The North Creek Second Addition preliminary plat plans have been distributed to Environmental Resources, Engineering Division, and Parks and Recreation Department staff. A. Location Map B. Zoning Map C. Preliminary Plat D. Grading and Removals E. Tree Inventory Plan F. Erosion Control & Landscape Plan G. Sanitary Sewer & Water Main (2 pages) H. Storm Sewer Construction I. August 15, 2025 Plat Commission Letter 2 PLANNING A NALYSIS PRELIMINARY PLAT Existing Conditions. The development site consists of one parcel that was platted as Outlot E, North Creek. In 2019, a preliminary plat for the North Creek development was approved by the City Council, and later that year the North Creek final plat was approved and recorded. This parcel was intended to be developed as the second and final phase of the plat, but ultimately the preliminary plat approval expired, thus requiring a new preliminary plat application for the development of the site. The use on the property has been primarily undeveloped agricultural land as well as a house, fence, shed, well, and septic on the property, which must be removed with the development of the site. The North Creek Second Addition plat area is located in Planning District 3 of the 2040 Comprehensive Plan, which guides the subject property for low/medium density residential development where city sewer is available. . The North Creek Second Addition preliminary plat area is currently zoned RST-2. The developer proposes to construct single-family homes and detached townhomes, both of which are a permitted use within the RST-2 District. Adjacent land uses and zoning are as follows: North – Single family homes (RST-2), 173rd Street East – Ely Avenue, single-family homes (RST-2) South –North Creek (P/OS) West – Pilot Knob Road, Manufactured Home Park (RSMH) City streets, sanitary sewer and water improvements for the area of North Creek Second will be financed and constructed by the developer. The development costs associated with the North Creek Second development are not programmed in the 2025– 2029 CIP. A preliminary plat may be deemed premature if any of the criteria listed in Chapter 10-2-4-1 of the Subdivision Ordinance exist. Eligible criteria pertain to a lack of adequate: drainage, water, streets, sanitary sewer, and public service capacity (police and fire protection). The other pertinent criteria pertain to inconsistencies with the City Comprehensive Land Use and Capital Improvement Plans (discussed above). Staff review of the North Creek Second Addition preliminary plat against these criteria finds that it is not a premature subdivision. . The North Creek Second Addition preliminary plat consists of 26 single family lots and 27 detached townhome lots on 13.35 acres. This results in a gross/net density of 3.97 units per acre. 3 SINGLE FAMILY LOT REQUIREMENTS Lots/Blocks. The following minimum single-family lot size requirements of the RST-2, Single- and Two-Family Residential District pertain to the North Creek Second Addition preliminary plat: Single family lot sizes within the North Creek Second Addition preliminary plat range from 8,404 square feet to 11,464 square feet in area. All of the single family lots meet the lot area, width and depth requirements of the RST-2 District. The following minimum requirements for single family building setbacks in the RST-2 District pertain to the North Creek Second Addition preliminary plat: 25 feet (garage) The proposed house pads shown on the North Creek Second Addition grading, drainage and erosion control plans indicate that all 26 single-family lots have adequate building pad areas that meet setback requirements for principal structures. The following minimum requirements for detached townhome building setbacks in the RST-2 District pertain to the North Creek Second Addition preliminary plat: 25 feet (garage) The proposed unit lots shown on the North Creek Second Addition preliminary plat have sufficient area to accommodate detached units. A homeowner’s association will be required to be established for ownership and maintenance of Lot 23, Block 1 and Lot 22, Block 3. Homeowner’s association documents must be reviewed and approved by the 4 City Attorney and proof of recording provided prior to issuance of any building permits for the detached townhomes. The RST-2 District requires at least 5,000 square feet per unit. The North Creek Second Addition preliminary plat has an average of 7,886 square feet per unit for the detached townhomes area, which exceeds the minimum lot area per unit requirements of the RST- 2 District. Each unit must meet the requirements of Section 11-57-19.B.3, which addresses exterior materials of the detached townhomes. Earlier this year, the City Council approved an ordinance amendment that removed the requirement for stone, brick, and/or stucco on the front elevation. The ordinance still requires a variety of materials and ensures that any one material doesn’t exceed 75% of one elevation. Variations in siding style, such as lap, shakes, and board and batten count as different materials to encourage variety. The Zoning Ordinance also deems the use of cement fiberboard material as satisfying the minimum masonry material requirement and is therefore also allowed to exceed the maximum area limit for non-masonry materials. Detached townhomes in the RST-2 District require garages to be a minimum of 20 feet in width and have an area of at least 440 square feet. All calculations are made with interior measurements. Each detached townhome unit must provide landscaping at the immediate perimeter of the unit. All landscaped areas including common open space and public right of way, must have an inground irrigation system with an automatic controller. With the final plat, the Developer must provide information that the landscaping of the detached townhome units meets the requirements of Section 11-58-21K. Seven single family lots and a portion of a townhome common area abut Pilot Knob Road and require increased buffer yard lot sizes and setbacks in the North Creek Second Addition preliminary plat. Pilot Knob Road is classified as a minor arterial in the Comprehensive Transportation Plan. The landscape plan includes the installation of 38 eight-foot tall spruce, pine, and arborvitae trees along the rear yards of Lots 1-7, Block 1 and a portion of Lot 23, Block 1. Prior to City Council consideration of the preliminary plat, the landscape plan must be modified to include the specific species of spruce and pine to be planted, subject to the approval of the City Forester. Lots 1-7, Block 1 and Lot 23, Block 1 must install sod within the buffer area to the rear property line. A $1,000 per lot security for Lots 1-7, Block 1 will be required with the building permit. A security for the plantings within the townhome common area lots must be provided with the final plat to guarantee the installation of the landscaping. There are no outlots proposed with the North Creek Second Addition preliminary plat. North Creek Second Addition will be developed in one phase. 5 Signs. No subdivision identification monument signs are proposed with the North Creek Second Addition preliminary plat. The following is a summary of streets proposed with the North Creek Second Addition preliminary plat. Additional detailed information is outlined in the Engineering Division memorandum dated November 24, 2025. Pilot Knob Road (CSAH 31) – Pilot Knob Road is west of and adjacent to the property and is classified as a minor arterial in the Comprehensive Transportation Plan. The required right of way for Pilot Knob Road was dedicated with the North Creek plat in 2019. No additional right of way is required to be dedicated. 174th Street – 174th Street will be a residential street constructed within a 60-foot right-of- way and a 32-foot-wide street with a five-foot-wide concrete sidewalk along one side of the street. 175th Street – 175th Street will be a residential street constructed within a 60-foot-wide right-of-way and a 32-foot-wide street between Encina Path and Ely Avenue. A five-foot- wide concrete sidewalk will be located on one side of the street. Encina Path – Encina Path will be extended south from it’s current terminus at Ely Avenue and will be a 32-foot-wide residential street constructed within a 60-foot-wide right-of-way with a five-foot wide concrete sidewalk along the west side of the street. Driveway access to Pilot Knob Road is prohibited for Lots 1-7, Block 1. All streets meet the minimum width and design requirements of the Subdivision Ordinance. Proposed grading, drainage, erosion control, and utilities for the North Creek Second Addition preliminary plat is shown on the grading, drainage and erosion control and utility plans. All existing and new local utilities shall be placed underground. Grading, drainage, erosion control, and utilities details are outlined in the November 24, 2025 engineering report prepared by Alanna Sobotka, Civil Engineer and Mac Cafferty, Environmental Resources Manager. The Engineering Division recommends approval of the preliminary plat. Because the North Creek Second Addition preliminary plat application was submitted prior to the adoption of the new tree preservation ordinance, it is not subject to the new ordinance. The trees on site are primarily Boxelder, Cottonwood, Willow, and Spruce; the last of which were planted on site by the previous owner for screening purposes. The submitted plan is consistent with what was approved as part of the original North Creek preliminary plat. The tree plan indicates there are 168 trees on site; however nearly all of trees proposed to be saved are outside the plat boundary and within the Pilot Knob Road ROW or the adjacent city-owned outlot. Prior to City Council consideration of the preliminary plat, the plan must be updated to 6 remove the offsite trees from the inventory and revise the numbers of the total trees on site, to be saved, and to be removed, as well as indicating on the plan which trees are proposed to be removed. A wetland delineation was completed and approved on 04/11/2018, as part of the original preliminary plat. No wetland impacts are proposed with the development. Mac Cafferty has reviewed the wetland delineation report and his comments are included in the November 24, 2025 engineering report. Land for North Creek Park was deeded to the City with the North Creek final plat in 2019, which satisfied a portion of the park dedication requirements for the original North Creek preliminary plat. Cash in lieu is required to be paid on 45.97 lots of the North Creek Second Addition plat and will be paid at the time of final plat. The developer will construct five-foot-wide concrete sidewalks along one side of all streets in the development. The City’s 2015 Parks, Trail and Open Space Plan identifies bituminous trails along Pilot Knob Road. Per the Pheasant Run of Lakeville 7th Addition Development Contract, the developer is required to construct a 10- foot-wide trail along the east side of Pilot Knob Road, from 173rd Street to 179th Street. The trail has been constructed from the south side of the North Creek creek to 179th Street. The North Creek Second Addition preliminary plat area is located within the current MUSA. A private overhead electric line and pole are located along the west property boundary. The developer will be required to place these utilities underground as a part of the improvements on the site. A security will be required to guarantee that the work is completed. The Dakota County Plat Commission reviewed and approved the preliminary plat at their August 13, 2025 meeting. The Plat Commission letter is included as Exhibit I. Community Development Department staff recommends approval of the North Creek Second Addition preliminary plat subject to the following stipulations: 1. Implementation of the recommendations listed in the November 24, 2025 engineering report. 2. Park dedication shall be satisfied with a cash contribution paid with the final plat for each development phase. 3. The developer shall construct five-foot-wide concrete sidewalks along one side of all streets. The Developer shall construct a 10-foot wide bituminous trail along the east side of Pilot Knob Road, from 173rd Street to the current terminus of the 7 bituminous trail on the south side of the North Creek creek, per the Pheasant Run of Lakeville 7th Addition development contract. 4. Buffer yard landscaping shall be installed according to the approved landscape plan. A security for the buffer yard landscaping shall be submitted with the final plat. 5. Lots 1-7, Block 1 must sod the buffer yard to the rear property line. A $1,000 per lot security for these lots will be required with the building permit. 6. All new local utilities and any existing overhead service utilities located on the property shall be placed underground. 7. The existing house, accessory structures, fence, well, and septic system must be removed with the development of this property. 8. A homeowner’s association must be established for ownership and maintenance of Lot 23, Block 1 and Lot 22, Block 3. 9. Prior to City Council consideration of the preliminary plat, the tree inventory must be revised to remove all off-site trees and the counts for total trees, to be saved, and to be removed updated on the plan, and to indicate on the plan which trees are proposed to be removed. 10. Prior to City Council consideration of the preliminary plat, the landscape plan must be modified to include the specific species of spruce and pine to be planted, subject to the approval of the City Forester. Dakota County, Microsoft, Vantor City of Lakeville Site Location Map North Creek Second Add Preliminary Plat 173RD ST EL K W O O D A V E 172ND ST PI L O T K N O B R D ( C S A H 3 1 ) North Creek Second Add. Plat area 176TH ST ELY AVE EN C I N A P A T H ± 175TH ST NORTH CREEK DR 177TH ST EM P I R E T R L EXHIBIT A P/OS P/OS P/OS RM-2RS-2 RSMH RSMH RST-2 RST-2 City of Lakeville Zoning Map North Creek Second Add Preliminary Plat 173RD ST EL K W O O D A V E 172ND ST PI L O T K N O B R D ( C S A H 3 1 ) North Creek Second Add. Plat area 176TH ST ELY AVE EN C I N A P A T H ± 175TH ST NORTH CREEK DR 177TH ST EM P I R E T R L EXHIBIT B I hereby certify that this plan was prepared by me, or under my direct supervision, and that I am a duly registered engineer under the laws of the State of Minnesota. Luke Warren Israelson 6001 Egan Drive, Ste 100, Savage, MN 55378 Phone: 952.226.3200 Web: www.kjwalk.com Preliminary Plat Registration #: 51362 SHEET 1 of 2 Date: 9/17/2025 FILE PATH: G:\.shortcut-targets-by-id\0B7rlATRBOKEBSGQ2T0JkZi0xUTg\Work Files\Lakeville Projects\North Creek\Drawings\DWGs\NC2-2.dwg 0 50 100 150 For Review September 17, 2025 Date: Revision: Original07/15/2025 Revised Per City Comments09/17/2025 5' 7' 10 ' 30 ' 25 ' 10 ' ROW TYPICAL SINGLE FAMILY LOT SETBACKS AND EASEMENTS ROW 20 ' HO U S E S E T B A C K GA R A G E S E T B A C K 20' 10' 10 ' 30 ' 25 ' 10 ' 20 ' HO U S E S E T B A C K GA R A G E S E T B A C K ROW 5' 7' 5' 7' LEGAL DESCRIPTION:OUTLOT E, NORTH CREEK, DAKOTA COUNTY, MINNESOTA SITE DATA TOTAL SITE AREA 581,319 SQ FT 13.345 AC. GROSS DEVELOPMENT AREA 13.345 AC. RIGHT OF WAY AREA (LOCAL STREET)2.662 AC. NET DEVELOPABLE AREA (GROSS DEV. AREA - ROW - BUFFER)10.475 AC. SINGLE FAMILY LOTS 26 LOTS DETACHED TOWNHOUSE LOTS 27 LOTS UNIT DENSITY GROSS 3.97 UNITS PER AC. NET 5.06 UNITS PER AC. ZONING CLASSIFICATION RST-2 SINGLE FAMILY LOT REQUIREMENTS (RST-2) MIN. LOT AREA - INTERIOR LOTS 8,400 S.F. MIN. LOT WIDTH AT SETBACK - INTERIOR LOTS 70 FEET MIN. LOT AREA - CORNER LOTS 10,200 S.F. MIN. LOT WIDTH AT SETBACK - CORNER LOTS 85 FEET MIN. LOT DEPTH - DOUBLE FRONTAGE 150 FEET SINGLE FAMILY MINIMUM SETBACKS (RST-2) FRONT (HOUSE/GARAGE) 20 FEET / 25 FEET SIDE 7 FEET SIDE (STREET)20 FEET REAR 30 FEET REAR (Pilot Knob Road)50 FEET TOWNHOMES MINIMUM SETBACKS (RM-1) ROW TO FRONT 25 FEET BETWEEN BLDGS 14 FEET SIDE (STREET)20 FEET REAR 30 FEET LOT BLOCK SQ FT ACRES 1 1 11,424 0.26 2 1 10,682 0.25 3 1 10,500 0.24 4 1 10,500 0.24 5 1 10,500 0.24 6 1 10,500 0.24 7 1 10,500 0.24 8 1 3,495 0.08 9 1 4,023 0.09 10 1 3,272 0.08 11 1 3,249 0.07 12 1 3,159 0.07 13 1 2,800 0.06 14 1 2,800 0.06 15 1 2,800 0.06 16 1 2,800 0.06 17 1 2,800 0.06 18 1 2,800 0.06 19 1 2,800 0.06 20 1 2,800 0.06 21 1 2,800 0.06 22 1 3,068 0.07 23 1 72,897 1.67 1 2 11,080 0.25 2 2 11,122 0.26 3 2 8,758 0.20 4 2 8,804 0.20 5 2 9,134 0.21 6 2 9,051 0.21 7 2 8,734 0.20 8 2 8,750 0.20 9 2 8,750 0.20 10 2 11,444 0.26 1 3 11,464 0.26 2 3 8,404 0.19 3 3 8,528 0.20 4 3 8,823 0.20 5 3 8,746 0.20 6 3 8,455 0.19 7 3 8,464 0.19 8 3 8,578 0.20 9 3 10,726 0.25 10 3 2,797 0.06 11 3 2,800 0.06 12 3 2,800 0.06 13 3 2,800 0.06 14 3 2,800 0.06 15 3 2,800 0.06 16 3 2,800 0.06 17 3 2,800 0.06 18 3 2,800 0.06 19 3 2,800 0.06 20 3 2,800 0.06 21 3 2,721 0.06 22 3 61,052 1.40 30' 25' 10'ROW TYPICAL DETACHED TOWNHOME LOT SETBACKS AND EASEMENTS ROW 20' 10' 10' 30' 25' ROW 14' 40' 70' 10' EXHIBIT C I hereby certify that this plan was prepared by me, or under my direct supervision, and that I am a duly registered engineer under the laws of the State of Minnesota. Luke Warren Israelson 6001 Egan Drive, Ste 100, Savage, MN 55378 Phone: 952.226.3200 Web: www.kjwalk.com Grading and Removals Registration #: 51362 SHEET 3 of 10 Date: 9/17/2025 FILE PATH: G:\.shortcut-targets-by-id\0B7rlATRBOKEBSGQ2T0JkZi0xUTg\Work Files\Lakeville Projects\North Creek\Drawings\DWGs\NC2-2.dwg 0 50 100 150 For Review September 17, 2025 Date: Revision: Original07/15/2025 Revised Per City Comments09/17/2025 REMOVE BITUMINOUS ENTRANCE REMOVE EXISTING SHEDS REMOVE EXISTING FENCE PI L O T K N O B R O A D REMOVE TREES PER TREE PRESERVATION PLAN REMOVALS EXHIBIT D I hereby certify that this plan was prepared by me, or under my direct supervision, and that I am a duly registered engineer under the laws of the State of Minnesota. Luke Warren Israelson 6001 Egan Drive, Ste 100, Savage, MN 55378 Phone: 952.226.3200 Web: www.kjwalk.com Preliminary Plat Registration #: 51362 SHEET 2 of 2 Date: 9/17/2025 FILE PATH: G:\.shortcut-targets-by-id\0B7rlATRBOKEBSGQ2T0JkZi0xUTg\Work Files\Lakeville Projects\North Creek\Drawings\DWGs\NC2-2.dwg 0 50 100 150 For Review September 17, 2025 Date: Revision: Original07/15/2025 Revised Per City Comments09/17/2025 EXHIBIT E I hereby certify that this plan was prepared by me, or under my direct supervision, and that I am a duly registered engineer under the laws of the State of Minnesota. Luke Warren Israelson 6001 Egan Drive, Ste 100, Savage, MN 55378 Phone: 952.226.3200 Web: www.kjwalk.com Erosion Control and Landscape Plan Registration #: 51362 SHEET 2 of 10 Date: 9/17/2025 FILE PATH: G:\.shortcut-targets-by-id\0B7rlATRBOKEBSGQ2T0JkZi0xUTg\Work Files\Lakeville Projects\North Creek\Drawings\DWGs\NC2-2.dwg CB & DROP IN INLET PROTECTORS SEED & BLANKET LEGEND RIP RAP SILT FENCE NOTES: MAXIMUM ALLOWABLE SLOPE 3:1 PONDS MAY BE USED AS TEMPORARY SEDIMENTATION BASINS DURING CONSTRUCTION, IF A POND IS USED AS A TEMP. SED. BASIN IT MUST BE CLEANED OUT PRIOR TO BEING PUT INTO SERVICE. DRAINAGE TO THE TEMPORARY SEDIMENTATION BASINS MUST BE MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. - MN DOT MIX 250(70LBS/AC) USED IN RIGHT OF WAY - MN DOT MIX 325(84LBS/AC) USED ON PONDS BELOW HWL - MN DOT MIX 328(88LBS/AC) USED ON PONDS ABOVE HWL STOCKPILES TO BE STABILIZED IF NOT UTILIZED FOR MORE THAN 7 DAYS. For Review September 17, 2025 Date: Revision: Original07/15/2025 Revised Per City Comments09/17/2025 0 50 100 150 1/ 3 T R E E HE I G H T ROOT CROWN AT FINISH GRADE, OR 1-2" ABOVE GRADE FINISH GRADE TILLED OR BROKEN UP SOIL MIN 12" DEEP 2" SETTLED LAYER OF MULCH 2X WIDTH OF ROOTBALL TREE HEIGHT IS MEASURED FROM THE TOP OF THE ROOT BALL TO THE BOTTOM OF THE LEADER SYMBOL ID#COMMON NAME SIZE # PS PINE/SPRUCE 8'-0" 23 AT ARBORVITAE "TECHNY"8'-0"15 TOTAL 38 EXHIBIT F I hereby certify that this plan was prepared by me, or under my direct supervision, and that I am a duly registered engineer under the laws of the State of Minnesota. Luke Warren Israelson 6001 Egan Drive, Ste 100, Savage, MN 55378 Phone: 952.226.3200 Web: www.kjwalk.com Sanitary Sewer & Water Main Construction Registration #: 51362 SHEET 5 of 10 Date: 9/17/2025 FILE PATH: G:\.shortcut-targets-by-id\0B7rlATRBOKEBSGQ2T0JkZi0xUTg\Work Files\Lakeville Projects\North Creek\Drawings\DWGs\NC2-2.dwg 0 50 100 150 8"x8" TEE STA=5+47, 10'RT 8" GATE VALVE STA=5+42, 10'RT 8"x6" REDUCER 6" GV&BOX FIRE HYDRANT (SEE HYDRANT RISER DETAIL) STA=5+87, 21'LTTNH=925.58 (PLUG WEEP HOLES) 8" 45° BEND STA=8+46, 2'RT Water main to be installed in strict accordance with the most current edition of the CEAM specifications.(EXISTING)C.S. 924.5 0+60, 30.0' RT WYE (0+72) INV 916.5LLE 922.6 8" 45° BENDSTA=9+06, 11'RT 8"x6" REDUCER 6" GV&BOX FIRE HYDRANT STA=11+12, 21'RT TNH=931.74 REMOVE8" TO 6" REDUCERTEMP. FIRE HYDRANT CONNECT TO EXISTING WATERMAIN For Review September 17, 2025 Date: Revision: Original07/15/2025 Revised Per City Comments09/17/2025 CONNECT TO EXISTING SANITARY REMOVE 8" TO 6" REDUCER TEMP. FIRE HYDRANT CONNECT TO EXISTING WATERMAIN 8" GATE VALVE STA=10+50, 8'RT C.S. 924.3 3+27, 30.0' RT WYE (2+52)INV 918.7 LLE 922.7 C.S. 923.9 3+90, 30.0' RTWYE (1+93) INV 918.3 LLE 922.3 C.S. 923.5 4+60, 30.0' RTWYE (1+23) INV 918.0 LLE 922.0 C.S. 923.1 5+30, 30.0' RTWYE (0+53) INV 917.8 LLE 921.8 C.S. 923.0 5+77, 30.0' RTWYE (0+07) INV 917.8 LLE 921.8 C.S. 923.3 6+46, 30.0' RTWYE (1+68) INV 918.0 LLE 922.0 C.S. 924.1 7+16, 30.0' RTWYE (0+98) INV 919.0 LLE 923.0 C.S. 926.9 7+96, 30.0' RT WYE (0+16) INV 918.0LLE 922.0 C.S. 927.7 8+26, 30.0' RT WYE (0+77) INV 918.0LLE 922.0 C.S. 928.2 8+95, 30.0' RT WYE (3+21) INV 918.0LLE 922.0 C.S. 928.39+24, 30.0' RTWYE (3+12) INV 918.0 LLE 922.0 C.S. 928.5 9+61, 30.0' RT WYE (2+74)INV 918.0 LLE 922.0 C.S. 929.0 10+72, 30.0' RTWYE (1+65) INV 918.4 LLE 922.4 C.S. 929.2 11+45, 30.0' RTWYE (0+93)INV 918.5 LLE 922.5 C.S. 928.9 12+00, 30.0' RT WYE (0+39)INV 918.2 LLE 922.2 C.S. 928.7 12+56, 30.0' RT WYE (3+20) INV 918.0LLE 922.0 C.S. 927.7 13+65, 30.0' RTWYE (2+12)INV 917.3 LLE 921.3 C.S. 925.5 14+19, 30.0' RT WYE (1+58) INV 917.0 LLE 921.0 C.S. 922.514+82, 30.0' RTWYE (0+97) INV 917.7 LLE 921.7 C.S. 923.4 4+89, 30.0' LT WYE (0+95) INV 918.6 LLE 922.6 C.S. 923.3 6+22, 30.0' LTWYE (1+91)INV 918.8 LLE 922.8 C.S. 928.2 8+78, 30.0' LTWYE (0+10)INV 918.8 LLE 922.8 C.S. 928.6 9+64, 30.0' LTWYE (2+77)INV 918.8 LLE 922.8 C.S. 929.2 10+72, 30.0' LTWYE (1+68)INV 918.8 LLE 922.8 C.S. 929.311+44, 30.0' RTWYE (0+95) INV 918.8 LLE 922.8 C.S. 929.1 11+96, 30.0' LT WYE (0+42) INV 918.8 LLE 922.8 C.S. 928.5 13+01, 30.0' LT WYE (2+78) INV 918.8 LLE 922.8 C.S. 928.1 13+55, 30.0' LT WYE (2+24) INV 918.8 LLE 922.8 C.S. 926.1 14+09, 30.0' LT WYE (1+70) INV 918.8 LLE 922.8 C.S. 922.0 15+07, 30.0' LT WYE (0+70)INV 918.8 LLE 922.8 C.S. 928.9 10+18, 30.0' LTWYE (2+22)INV 918.8 LLE 922.8 C.S. 928.8 12+47, 30.0' LT WYE (3+32) INV 918.8 LLE 922.8 C.S. 923.5 14+62, 30.0' LT WYE (1+16)INV 918.8 LLE 922.8 C.S. 928.4 13+11, 30.0' RT WYE (2+66) INV 917.7LLE 921.7 C.S. 928.8 10+17, 30.0' RT WYE (2+19) INV 918.1LLE 922.1 C.S. 928.08+59, 30.0' RTWYE (0+42) INV 918.0 LLE 922.0 EXHIBIT G I hereby certify that this plan was prepared by me, or under my direct supervision, and that I am a duly registered engineer under the laws of the State of Minnesota. Luke Warren Israelson 6001 Egan Drive, Ste 100, Savage, MN 55378 Phone: 952.226.3200 Web: www.kjwalk.com Registration #: 51362 SHEET 6 of 10 Date: 9/17/2025 FILE PATH: G:\.shortcut-targets-by-id\0B7rlATRBOKEBSGQ2T0JkZi0xUTg\Work Files\Lakeville Projects\North Creek\Drawings\DWGs\NC2-2.dwg 0 50 100 150 Sanitary Sewer & Water Main Construction 8"x6" REDUCER 6" GV&BOX FIRE HYDRANT12' BURYSTA=4+05, 21'LT TNH=925.48 (PLUG WEEP HOLES) REMOVE 8" TO 6" REDUCER TEMP. FIRE HYDRANT CONNECT TO EXISTING WATERMAIN 8" GATE VALVE STA=0+15, 10'LT Water main to be installed in strict accordance with the most current edition of the CEAM specifications. For Review September 17, 2025 Date: Revision: Original07/15/2025 Revised Per City Comments09/17/2025 CONNECT TO EXISTING SANITARY C.S. 923.41+67, 30.0' LTWYE (2+24) INV 918.6 LLE 922.6 C.S. 923.1 2+41, 30.0' LT WYE (1+53)INV 918.5 LLE 922.5 C.S. 922.8 3+14, 30.0' LT WYE (0+82) INV 918.2LLE 922.2 C.S. 922.8 3+60, 30.0' LTWYE (0+35)INV 918.2 LLE 922.2 C.S. 923.1 4+27, 30.0' LT WYE (3+06) INV 918.2LLE 922.2 C.S. 923.3 5+19, 30.0' LT WYE (2+13) INV 918.2 LLE 922.2 C.S. 922.9 5+89, 30.0' LTWYE (1+43) INV 918.2 LLE 922.2 C.S. 922.6 6+58, 30.0' LTWYE (0+74) INV 918.2 LLE 922.2 C.S. 922.76+65, 30.0' RTWYE (0+68) INV 918.8 LLE 922.8 C.S. 923.0 5+95, 30.0' RT WYE (1+37) INV 918.8LLE 922.8 C.S. 923.35+25, 30.0' RTWYE (2+07) INV 918.8 LLE 922.8 C.S. 923.2 4+32, 30.0' RT WYE (3+00) INV 918.8LLE 922.8 C.S. 922.9 3+52, 30.0' RTWYE (0+41)INV 918.8 LLE 922.8 C.S. 922.9 3+06, 30.0' RT WYE (0+87) INV 918.8LLE 922.8 C.S. 923.2 2+37, 30.0' RTWYE (1+58) INV 918.8 LLE 922.8 C.S. 923.5 1+69, 30.0' RT WYE (2+28) INV 918.8LLE 922.8 I hereby certify that this plan was prepared by me, or under my direct supervision, and that I am a duly registered engineer under the laws of the State of Minnesota. Luke Warren Israelson 6001 Egan Drive, Ste 100, Savage, MN 55378 Phone: 952.226.3200 Web: www.kjwalk.com Storm Sewer Construction Registration #: 51362 SHEET 7 of 10 Date: 9/17/2025 FILE PATH: G:\.shortcut-targets-by-id\0B7rlATRBOKEBSGQ2T0JkZi0xUTg\Work Files\Lakeville Projects\North Creek\Drawings\DWGs\NC2-2.dwg 0 50 100 150 For Review September 17, 2025 Date: Revision: Original07/15/2025 Revised Per City Comments09/17/2025 EXHIBIT H Dakota County Surveyor’s Office Western Service Center  14955 Galaxie Avenue  Apple Valley, MN 55124 952.891 -7087  Fax 952.891 -7127  www.co.dakota.mn.us August 15, 2025 City of Lakeville 20195 Holyoke Ave. Lakeville, MN 55044 Re: NORTH CREEK SECOND ADDITION The Dakota County Plat Commission met on August 13, 2025, to consider the preliminary plat of the above referenced plat. The plat is adjacent to CSAH 31 (Pilot Knob Rd.) and is therefore subject to the Dakota County Contiguous Plat Ordinance. The proposed plat is a replat of Outlot E, NORTH CREEK. The future right of way needs are 100 feet of half right of way along CSAH 31. The plat includes the proper road dedication along CSAH 31. Restricted access is shown along all of Outlot E. There were no other comments. The Plat Commission has approved the preliminary and final plat and will recommend approval to the County Board of Commissioners meeting on September 9, 2025. Traffic volumes on CSAH 31 are 21,672 ADT and are anticipated to be 33,000 ADT by the year 2040. These traffic volumes indicate that current Minnesota noise standards for residential units could be exceeded for the proposed plat. Residential developments along County highways commonly result in noise complaints. In order for noise levels from the highway to meet acceptable levels for adjacent residential units, substantial building setbacks, buffer areas, and other noise mitigation elements should be incorporated into this development. No work shall commence in the County right of way until a permit is obtained from the County Transportation Department and no permit will be issued until the plat has been filed with the County Recorder’s Office. The Plat Commission does not review or approve the actual engineering design of proposed accesses or other improvements to be made in the right of way. Nothing herein is intended to restrict or limit Dakota County’s rights with regards to Dakota County rights of way or property. The Plat Commission highly recommends early contact with the Transportation Department to discuss the permitting process which reviews the design and may require construction of highway improvements, including, but not limited to, turn lanes, drainage features, limitations on intersecting street widths, medians, etc. Please contact TJ Bentley regarding permitting questions at (952) 891-7115 or Todd Tollefson regarding Plat Commission or Plat Ordinance questions at (952) 891-7070. Sincerely, Todd B. Tollefson Secretary, Plat Commission c: Luke Israelson, KC Walk EXHIBIT I City of Lakeville Public Works – Engineering Division Memorandum To: Kris Jenson, Planning Manager Alanna Sobottka, Civil Engineer McKenzie L. Cafferty, Environmental Resources Manager Joe Masiarchin, Parks and Recreation Director Zach Johnson, City Engineer Julie Stahl, Finance Director Dave Mathews, Building Official November 24, 2025 North Creek Second Addition • Preliminary Plat Review • Preliminary Erosion and Sediment Control Plan Review • Preliminary Grading and Drainage Plan • Preliminary Utility Plan Review • Preliminary Tree Preservation Plan Review KJ Walk, Inc. has submitted a preliminary plat named North Creek Second Addition. The proposed subdivision is located south of and adjacent to 173rd Street, east of and adjacent to Pilot Knob Road (CSAH 31), north and west of and adjacent to two Vermillion River Watershed Joint Powers Organization (VRWJPO) principal connectors (Tributary No. 1 to North Creek and North Creek). The parent parcel consists of Outlot E, North Creek (PID No. 225208000050) zoned RST-2. The preliminary plat consists of twenty-six (26) single family lots, twenty-seven (27) detached townhome lots, and two (2) Homeowners Association (HOA) common lots within three (3) blocks on 13.35 acres. The proposed development will be completed by: Developer: KJ Walk, Inc. Engineer/Surveyor: KJ Walk, Inc. NNOORRTTHH CCRREEEEKK SSEECCOONNDD AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY PPLLAATT NNOOVVEEMMBBEERR 2244,, 22002255 PPAAGGEE 22 OOFF 66 SSIITTEE CCOONNDDIITTIIOONNSS The North Creek Second Addition site consists of Outlot E, North Creek totaling 13.35 acres and lies north of North Creek, which runs along the southern property line from the west to the east. The parcel consists of land that was primarily mass graded with the development of North Creek. There was a previous homestead with a house, fence, sheds, well and septic on the property that shall be removed in full with the development of the site. Pilot Knob Road (CSAH 31) North Creek Second Addition is located east of and adjacent to Pilot Knob Road, a minor arterial County highway, as identified in the City’s Transportation Plan. Pilot Knob Road adjacent to the site is a four-lane divided rural roadway. The current Dakota County Plat Review Needs Map indicates a half right-of-way requirement of 100-feet and designates it as a future six-lane divided urban roadway over its entire length adjacent to the plat. The expansion of Pilot Knob Road to a six-lane roadway is not identified in the City’s or County’s current Capital Improvement Plans. The preliminary plat was reviewed and recommended for approval by the Dakota County Plat Commission at its August 15, 2025 meeting. There will be no access to the development from Pilot Knob Road. 175th Street The development of North Creek Second Addition includes the extension of 175th Street, a local street. 175th Street is designed as a 32-foot wide, two-lane urban roadway with a five- foot concrete sidewalk along the south side of the street. The Developer is dedicating 60-feet of right-of-way in compliance with City ordinance requirements. Encina Path Development of North Creek Second Addition includes the extension of Encina Path, a local street which will be extended south from it’s current terminus at the north boundary of North Creek Second Addition. Encina Path is designed as a 32-foot wide, two-lane urban roadway with a five-foot concrete sidewalk along the west side of the street. The Developer is dedicating 60-feet of right-of-way in compliance with City ordinance requirements. 174th Street The development of North Creek Second Addition includes the construction of 174th Street, a local street. 174th Street is designed as a 32-foot wide, two-lane urban roadway with a five- foot concrete sidewalk along the north side of the street. The Developer is dedicating 60-feet of right-of-way in compliance with City ordinance requirements. Construction traffic access and egress for grading, utility, and street construction shall be through a rock construction entrance on Encina Path south of 173rd Street. NNOORRTTHH CCRREEEEKK SSEECCOONNDD AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY PPLLAATT NNOOVVEEMMBBEERR 2244,, 22002255 PPAAGGEE 33 OOFF 66 PPAARRKKSS,, TTRRAAIILLSS AANNDD SSIIDD EEWWAALLKKSS Development of North Creek Second Addition includes the construction of public sidewalks along the west side of Encina Path, north side of 174th Street, and the south side of 175th Street. The parks and trails within North Creek Second Addition are to be developed to allow for connection to other local and regional facilities as part of the City’s overall Parks, Trails and Open Space System Plan. Consistent with the City’s Parks Trails and Open Space Plan and the Pheasant Run of Lakeville 7th Addition Development Contract the Developer shall construct a 10-foot trail along the east side of Pilot Knob Road adjacent to the plat. The Developer shall construct the trail from 173rd Street to the current terminus of the bituminous trail previously constructed to the south with the Pheasant Run of Lakeville 7th Addition plat. A grading permit will not be approved for the site until a bituminous trail design is approved by both City and County staff. The park dedication requirement for the parent parcels has not been collected and shall be satisfied through a cash contribution that shall be paid with the final plat. North Creek Second Addition is located within subdistrict NC-20010 of the North Creek sanitary sewer district as identified in the City’s Comprehensive Sewer Plan. The Developer is proposing to direct all wastewater from the preliminary plat through the NC-20010 subdistrict; the City has reviewed this proposal and determined that the downstream facilities have sufficient capacity to serve the proposed subdivision. Wastewater will be conveyed to the MCES Farmington Interceptor and continue to the Empire Wastewater Treatment Facility. The Sanitary Sewer Availability Charge has not been collected on the parent parcel and shall be paid with the final plat. Development of North Creek Second Addition includes the extension of 8-inch watermain within the subdivision. Watermain to serve the lots within North Creek Second Addition will be extended from the existing 8-inch watermain stub at the north boundary of the plat in Encina Path. The remainder of the lateral watermain access charge for the portion of 12-inch watermain within Pilot Knob Road right-of-way shall be paid with the final plat An overhead electric transmission line and poles are located along the east side of Pilot Knob Road on the parent parcel servicing the previous house and farmstead. The Developer is required to remove the poles and place the utilities underground with the final plat, NNOORRTTHH CCRREEEEKK SSEECCOONNDD AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY PPLLAATT NNOOVVEEMMBBEERR 2244,, 22002255 PPAAGGEE 44 OOFF 66 consistent with the City’s Public Ways and Property Ordinance. A security will be required with the final plat to ensure proper removal of poles and placement of utilities underground. North Creek is located within subdistricts NC-18 and NC-20 of the North Creek stormwater district as identified in the City’s Water Resources Management Plan. Stormwater within North Creek Second Addition is directed east into the existing stormwater management basin constructed with North Creek. The basin will provide water quality treatment, volume and rate control of the stormwater runoff generated from the North Creek Second Addition plat. The stormwater basin design is consistent with City requirements. The stormwater basin discharges to Tributary No.1 to North Creek, which is east of the preliminary plat. The development of North Creek Second Addition includes lots adjacent to the VRWJPO principal connector North Creek. The 100-yr Flood elevation as determined by the City’s stormwater model will be contained outside of the plat everywhere possible. Natural Area signs will be placed along easement lines impacted by the 100-yr Flood elevations. A security will be required with the final plat to ensure proper installation of signs. Final locations will be identified in the field. The final grading plan shall identify all fill lots in which the building footings will be placed on fill material. The grading specifications shall also indicate that all embankments meet FHA/HUD 79G specifications. The Developer shall certify to the City that all lots with footings placed on fill material are appropriately constructed. Building permits will not be issued until a soils report and an as-built certified grading plan have been submitted and approved by City staff. North Creek Second Addition contains more than one acre of site disturbance. A National Pollution Discharge Elimination System General Stormwater Permit for construction activity is required from the Minnesota Pollution Control Agency for areas exceeding one acre being disturbed by grading. A copy of the Notice of Stormwater Permit Coverage must be submitted to the City upon receipt from the MPCA. Development of North Creek Second Addition includes the construction of public storm sewer systems. Storm sewer will be installed within the subdivision to collect and convey stormwater runoff generated from within the public right-of-way and lots to the existing public stormwater management basin located east of the development. Runoff is conveyed from rear yard lots to the VRWJPO principal connector North Creek. Draintile construction is required in areas of non-granular soils within North Creek Second Addition for the street sub-cuts and lots. Any additional draintile construction, including NNOORRTTHH CCRREEEEKK SSEECCOONNDD AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY PPLLAATT NNOOVVEEMMBBEERR 2244,, 22002255 PPAAGGEE 55 OOFF 66 perimeter draintile required for building footings, which is deemed necessary during construction shall be the Developer’s responsibility to install and finance. The Trunk Storm Sewer Area Charge has not been collected on the parent parcels and shall be paid with the North Creek Second Addition final plat. Final locations and sizes of all storm sewer facilities will be reviewed by City staff with the final construction plans. A portion of the North Creek Second Addition preliminary plat is shown on the Flood Insurance Rate Map (FIRM #27037C0208E effective 12/2/2011) as Zone AE by the Federal Emergency Management Agency (FEMA). Based on this designation, a portion of the plat is located within a Special Flood Hazard Area (SFHA), as determined by FEMA. The remainder of the plat is shown on the Flood Insurance Rate Map (FIRM) as Zone X by the Federal Emergency Management Agency (FEMA). The wetland delineation for this site was approved on 4/11/2018 and the delineation was completed by Kjolhaug Environmental Services. No wetland impacts are proposed with the development. All wetlands/waterways and required buffers will be placed in an outlot dedicated to the city. The waterway is identified as a Principal Connector and requires a buffer width 100-foot average, 65-foot minimum measured from the edge of the meander belt of the river. Buffers must be shown on the plans prior to final plat. The Developer will be responsible for the installation of the required Natural Area signs. Final locations will be identified in the field. A tree preservation plan has been submitted. The tree plan indicates there are 168 trees on site; however nearly all of the total trees proposed to be saved are within the Pilot Knob Road ROW or within the adjacent city-owned outlot. Prior to City Council consideration of the preliminary plat, the plan must be updated to remove the offsite trees from the inventory and revise the numbers of the total trees on site, to be saved, and to be removed. The tree preservation plan will need to be updated to indicate the trees that will be removed on the plan drawing. The plan also needs to include a temporary tree protection fence detail as well as identify the placement of tree protection fencing on the plan drawing. All “save” trees that are damaged or removed will require replacement at a ratio of 2:1 as per the Lakeville Subdivision Ordinance. Prior to any removals the tree protection fence line must be staked and reviewed by City Staff. NNOORRTTHH CCRREEEEKK SSEECCOONNDD AADDDDIITTIIOONN –– PPRREELLIIMMIINNAARRYY PPLLAATT NNOOVVEEMMBBEERR 2244,, 22002255 PPAAGGEE 66 OOFF 66 EERROOSSIIOONN CCOONNTTRROOLL The Developer is responsible for obtaining an MPCA Construction Permit for the site as well as developing a SWPPP for the site prior to construction. The SWPPP must be submitted and approved by the City prior to grading. The permit requires that all erosion and sediment BMPs be clearly outlined in a site’s SWPPP. Changes made throughout construction should be documented in the SWPPP. Additional erosion control measures may be required during construction as deemed necessary by City staff or the Vermillion River Watershed JPO. Any additional measures require shall be installed and maintained by the Developer. RREECCOOMMMMEENNDDAATTIIOONN Engineering recommends approval of the North Creek Second Addition preliminary plat, grading and erosion control plan, utility plan and tree preservation plan, subject to the requirements and stipulations within this report.