Loading...
HomeMy WebLinkAboutItem 05a - Prime 35 Preliminary platCity of Lakeville Community Development Memorandum To: Planning Commission Heather Botten, Senior Planner February 23, 2025 Packet Material for the March 5, 2026 Planning Commission Meeting Crosby Development Partners, LLC. -Preliminary plat of Prime 35 Industrial April 1, 2026 (120-day deadline) Representatives from Crosby Development Partners, LLC have submitted an application for a preliminary plat for an eight lot, five outlot subdivision and preliminary plan set for an industrial development to be known as Prime 35 Industrial. The eight lots would be used for industrial development that will consist of warehouse, distribution, and manufacturing type businesses, with the final build out adding over one million square feet of industrial space. Two of the outlots are proposed to be deeded to the city to protect the wetlands while the others would be retained by the developer. The property is zoned I-1, Light Industrial. The proposed development is located south of 215th Street (CSAH 70), west of Jacquard Avenue. The two parent parcels total 145 acres in area, including right-of-way. The property is currently used for agricultural purposes that contain wetlands. There is one natural gas pipeline that dissects the property from west to east and the property is located in floodplain areas associated with the West Branch South Creek corridor. The Prime 35 Lakeville preliminary plat and development plans have been reviewed by Community Development, Engineering, Environment Resources Division, and the City Forester, as well as Barr Engineering for stormwater review. A. Location Map B. Zoning Map C. Preliminary Plat 2 D. Existing Conditions E. Site Plan F. Grading and Drainage Plan G. Landscape Plan H. Tree Preservation Plan I. Dakota County Plat Commission Letter The development consists of two parent parcels, zoned I-1, Light Industrial Development. The property is currently guided for Warehouse/Light Industrial land uses in Planning District No. 6 of the 2040 Comprehensive Land Use Plan. A comprehensive plan amendment to adjust the staging on the westerly part of the property from Expansion Area B to current Municipal Urban Service Area (MUSA) was approved by the City Council on August 18, 2025 and approved by the Metropolitan Council on November 12, 2025. The proposed preliminary plat is consistent with the recommended goals and objectives of the comprehensive plan. The site is currently undeveloped and historically used for agricultural production of row crops. There is a gas easement that dissects the property along with wetlands. Industrial, Office Park I-1, Light Industrial Lot 1, Block 2 is proposed to be accessed by 215th Street. The remainder of the site will be accessed from 217th Street. Prime 35 Industrial development includes the construction of Javelin Avenue and 217th Street. The roads shall be constructed to City standards and will provide access to 215th Street (CSAH 70). The Dakota County Plat Commission recommended approval of the preliminary plat at the January 18, 2026 meeting subject to the requirements in the approval letter dated January 19, 2026. 3 Lot Frontage. City code requires each lot to have frontage on an abutting, improved, and city- accepted public street except as may be allowed by a conditional use permit (CUP). Lot 2, Block 4 is proposed south of Lot 1, Block 4 and does not have street frontage, instead relying on shared access with Lot 1, Block 4. Therefore, a CUP is required for this configuration. A CUP has not been processed with the preliminary plat as several potential scenarios could occur. For example, the final plat could designate these areas as outlots and will then be platted as a lot in the future. Other options include the combination of Lots 1 and 2, Block 4 into a single lot, eliminating the need for a CUP, or the lot boundaries could be adjusted to provide Lot 2 with frontage on 217th Street. A stipulation is included stating that, as currently proposed, Lot 2, Block 4 will require a CUP in accordance with Section 11-16-5.G prior to final plat approval. Over 2,200 trees were inventoried on the property. Development in industrial districts may remove up to seventy percent (70%) of the total diameter inches of significant trees without replacement; any removal or disturbance of trees beyond this threshold shall require replacement tree planting or mitigation. Trees within the South Creek corridor will remain undisturbed. The City Forester is working with the applicant on compliance with the tree preservation ordinance. The project area consists of wetlands, drainage features, and floodplain areas associated with the West Branch South Creek corridor. Portions of the site are located within the FEMA mapped floodplain. A wetland delineation for the site was approved June 18th, 2025. A wetland replacement plan was submitted and is out for comment. The replacement identifies 2 acres of wetland impacts to previously farmed wetlands. All protected wetlands, waterways, floodplains and buffers will be placed in City owned outlots with the final plat. Any wetland impacts will be approved by the City, with the applicant working with Environmental Resources The Comprehensive Parks, Trails, and Open Space Plan does not identify any future park land needs in the area of the plat. Park dedication will be satisfied at the time of final plat with a cash fee determined by the most recent fee schedule for industrial zoned property. The development of Prime 35 Industrial includes the construction of a 10-foot-wide bituminous trail, constructed on the south side of 215th Street/CSAH 70, adjacent to the plat frontage. The Developer will be responsible for 100% of the grading and restoration for the bituminous trail to the length of the plat. The Developer shall receive a credit to the final plat cash fees for the City’s 3/8th share (excluding grading and restoration) of the trail construction costs. The Prime 35 Industrial plat proposes eight lots and five outlots. All of the lots within the plat exceed the minimum lot area and width requirements in the I-1 District. 4 Minimum Lot Area Minimum Lot Width Minimum Required 30,000 square feet 100 feet Lot 1, Block 1 476,731 sf +800 feet Lot 1, Block 2 544,723 sf 1,003 feet Lot 1, Block 3 621,273 sf 1,610 feet Lot 1, Block 4 499,261 sf 1,177 feet Lot 2, Block 4 647,984 sf 1,318 feet Lot 3, Block 4 376,955 sf 445 feet Lot 4, Block 4 747,193 sf 110 feet Lot 5, Block 4 458,861 sf +1,100 feet . The minimum building setback requirements within the I-1 District are: The proposed buildings shall comply with the minimum code requirements. The setback requirements for parking lots and drive aisles is 15 feet abutting right-of-way and five feet from interior lot lines. The proposed parking areas and drive aisles comply with the minimum setback requirements. The proposed site plan has drive areas that cross over internal property boundaries, a cross-access agreement will be required with the final development plans. The exterior building materials of all structures shall comply with City Code Section 11-17-9. Architectural information will be provided at the final submittal for each lot. Building Height. The maximum height for any building is 50 feet. . Any roof-mounted mechanical equipment must be screened if greater than three feet in height. Ground-mounted mechanical equipment must be screened with landscaping and/or fencing. Outdoor storage, including parking of semi-tractor trailers is allowed as an accessory use and shall comply with City Code Section 11-86-5. The landscape plan proposes a mix of deciduous and ornamental trees and shrubs mainly located around parking lots and private drives. The City Forester has reviewed the 5 landscape plans dated January 30, 2026 and is working with the applicant on landscape compliance. Landscaping on site must be installed per approved plans. The Developer must provide a security with the final plat to guarantee installation of the landscaping. Prior to a final landscape inspection, an as-built landscape plan must be submitted to the city. . No signs are proposed or approved with the application. Any signs to be installed upon the property are to comply with Zoning Ordinance requiremenst. All signs require approval of a sign permit prior to installation. No light source or combination thereof which casts light on a public street shall exceed one foot-candle meter reading as measured at the right of way or property line. All building- mounted lighting must face downward onto the structure. A photometric lighting plan for the proposed exterior lighting shall be submitted with the development of each lot in compliance with the Zoning Ordinance. Lighting for the proposed streets will be provided during the permitting phase and will meet city standards. Grading, drainage and erosion control plans have been submitted with the preliminary plat. City Engineering and Environmental Resources have reviewed the civil plan set. A copy of the engineering report dated February 23, 2026 is attached for your review. The Engineering Division recommends approval of the preliminary plat subject to the stipulations outlined in the report. A Stormwater Maintenance Agreement will be required with the final plat for maintenance of the stormwater systems on site. If trash will be kept outdoors in an enclosure, the structure must meet the requirements of Section 11-18-11, including exterior materials, location, and screening. Community Development Department staff recommends approval of the Prime 35 Lakeville preliminary plat, subject to the following stipulations: 1. All grading, drainage, wetland, and erosion control issues and plans shall be subject to review and approval of the City Engineer, including implementation of the recommendations listed in the February 23, 2026 engineering report. 2. The final plat shall be in substantial conformance with the preliminary plans on file with the Community Development Department except as may be modified by the conditions herein. 6 3. An agreement for any shared driveway access points shall be established in conjunction with the recording of the final plat, subject to review and approval of the Zoning Administrator. 4. As currently proposed, Lot 2, Block 4 will require a CUP in accordance with Section 11-16- 5.G prior to final plat approval. 5. Outlots A and C shall be deeded to the City for stormwater management purposes with the final plat. 6. Park dedication requirements shall be satisfied at the time of final plat approval based on the fee schedule then in effect. 7. The preliminary plat shall be valid for one year from the date of City Council approval unless extended as provided for by the Subdivision Ordinance and Zoning Ordinance. 8. Landscaping shall be installed in accordance with the approved landscape plan, subject to review and approval of the City Forester. 9. The Developer shall provide a security in an amount determined by the City Forester with the final plat to guarantee installation of the landscaping and prior to a final landscape inspection by the City Forester, an as-built landscape plan must be submitted to the city. 10. Any signs installed upon the property shall comply with Chapter 23 of the Zoning Ordinance and shall require a sign permit approved by the Zoning Administrator prior to placement. 11. Applicant shall enter into a Development Contract and related agreements with the City subject to review by the City Attorney and approval of the City Council prior to approval of a final plat. City of Lakeville Public Works – Engineering Division Memorandum To: Heather Botten, Senior Planner Jonathan Nelson, Assistant City Engineer Mac Cafferty, Environmental Resources Manager Joe Masiarchin, Parks and Recreation Director Zach Johnson, City Engineer Tina Goodroad, Community Development Director Julie Stahl, Finance Director Dave Mathews, Building Official February 23, 2026 Prime 35 Industrial • Preliminary Plat Review • Preliminary Grading and Erosion Control Plan Review • Preliminary Utility Plan Review • Preliminary Tree Preservation Review Olam Holdings 1, LLC has submitted a preliminary plat named Prime 35 Industrial. The proposed subdivision is located south of and adjacent to 215th Street (CSAH 70) and west of and adjacent to the existing western terminus of 217th Street. The parent parcels are identified as PID Nos. 220310051012 and 220360075013, zoned I-1, Light Industrial. The preliminary plat consists of eight (8) industrial lots and five (5) outlots on 145.21 acres. The outlots created with the preliminary plat shall have the following use: • Outlot A: Wetland and Buffer; to be deeded to the City (8.25 acres) • Outlot B: Future development; to be retained by developer (5.37 acres) • Outlot C: Wetland and Buffer; to be deeded to the City (1.07 acres) • Outlot D: Future Development; to be retained by developer (2.17 acres) PPRRIIMMEE 3355 IINNDDUUSSTTRRIIAALL –– PPRREELLIIMMIINNAARRYY PPLLAATT FFEEBBRRUUAARRYY 2233,, 22002266 PPAAGGEE 22 OOFF 55 • Outlot E: Stormwater management; to be retained by developer (19.47 acres) The proposed development will be completed by: Developer: Olam Holdings 1, LLC Engineer/Surveyor: MN Hill The Prime 35 Industrial site consists of undeveloped agricultural land containing wetlands, drainage features, and floodplain areas associated with the West Branch South Creek corridor. Existing topography generally drains toward the creek corridor and associated wetland complexes located within the site. Public utilities are located within adjacent roadway rights- of-way and will be extended to serve the proposed development. There is a gas main easement with Northern Natural Gas that bisects the site. Construction activities within the easement area must be coordinated and permitted with Northern Natural Gas. Portions of the site are located within the FEMA mapped floodplain and are proposed to be deeded to the City as an outlot. 215th Street (CSAH 50) Prime 35 Industrial is located south of and adjacent to 215th Street (CSAH 70), which is classified as a minor arterial roadway as identified in the City’s Transportation Plan. The Dakota County Plat Review Needs Map identifies CSAH 70 as a future four-lane divided roadway requiring seventy-five (75) feet of half right-of-way. The Developer shall dedicate the necessary right-of-way as shown on the preliminary plat. The preliminary plat was reviewed and recommended for approval by the Dakota County Plat Commission at their January 29, 2026 meeting upon meeting the described conditions in the plat commission letter. 217th Street Prime 35 Industrial includes the construction of 217th Street, a local roadway, within the plat boundary. 217th Street shall be constructed to City standards as a 40-foot-wide industrial roadway section with two-foot-wide gravel shoulders within 80-foot dedicated right-of-way and will provide access to proposed industrial lots and future development areas located west of the plat. Javelin Avenue Prime 35 Industrial includes the construction of Javelin Avenue, a local roadway. Javelin Avenue shall be constructed to City standards as a 40-foot-wide industrial roadway section with two-foot-wide gravel shoulders within 80-foot dedicated right-of-way and will provide access to 215th Street (CSAH 70). A right-of-way permit with Dakota County is required for construction proposed within Dakota County right-of-way. PPRRIIMMEE 3355 IINNDDUUSSTTRRIIAALL –– PPRREELLIIMMIINNAARRYY PPLLAATT FFEEBBRRUUAARRYY 2233,, 22002266 PPAAGGEE 33 OOFF 55 CCOONNSSTTRRUUCCTTIIOONN AACCCCEESSSS Construction traffic access and egress for grading, utility and street construction will limit use of the existing adjacent local roadways to the maximum extent practical for the construction. The City’s Parks, Trails and Open Space Plan does not designate a park within Prime 35 Industrial. The Park Dedication requirement has not been collected on the parent parcel and shall be satisfied through a cash contribution with the final plat. Prime 35 Industrial includes the construction of public trails. 10-foot-wide bituminous trail shall be constructed on the south side of 215th Street (CSAH 50) adjacent to the plat frontage. The Developer will be responsible for 100% of the grading and restoration for the bituminous trail. The Developer shall receive a credit to the final plat cash fees for the City’s 3/8th share (excluding grading and restoration) of the trail construction costs. Prime 35 Industrial is located within subdistrict SC-10190, SC-10420, and SC-10430 of the South Creek sanitary sewer district as identified in the City of Lakeville Sanitary Sewer Comprehensive Plan. Development includes extension of sanitary sewer to serve the proposed industrial lots. Consistent with the City’s Sanitary Sewer Comprehensive Plan, 8” trunk sanitary main will be extended to the western plat boundary to serve future development. Wastewater from the development will be conveyed through existing downstream sanitary sewer infrastructure to the Empire Treatment Facility monitored by meter M649. The development of Lot 1, Block 2 of Prime 35 Industrial shall enter into a special assessment agreement with the City for the reconstruction of 215th Street with trunk sanitary sewer and trunk watermain to provide availability of utility service to the site, consistent with City Comprehensive plans. The Sanitary Sewer Availability Charge has not been collected on the parent parcel and shall be paid with the final plat at the rate in effect at the time of approval. Prime 35 Industrial includes the extension of watermain to serve the proposed industrial lots. Consistent with the City’s Comprehensive Water System Plan, 12-inch trunk watermain will be extended to the west plat boundary to serve future development. The development of Lot 1, Block 2 of Prime 35 Industrial shall enter into a special assessment agreement with the City for the reconstruction of 215th Street with trunk sanitary sewer and PPRRIIMMEE 3355 IINNDDUUSSTTRRIIAALL –– PPRREELLIIMMIINNAARRYY PPLLAATT FFEEBBRRUUAARRYY 2233,, 22002266 PPAAGGEE 44 OOFF 55 trunk watermain to provide availability of utility service to the site, consistent with City Comprehensive plans. The City will credit the Developer for the oversizing of the trunk watermain in 217th Street. The credit will be based on the cost difference between 8-inch watermain and the oversized watermain that will be installed. The credit will be applied to the Developer’s final plat cash fees and will be based on an estimate provided by the Developer’s engineer. Prime 35 Industrial is located within subdistricts SC-174, SC-187, SC-021, SC-006, SC-022, SC- 199-3P as identified in the City of Lakeville Water and Natural Resources Management Plan. Development includes construction of five (5) privately owned and maintained stormwater management facilities to collect and treat runoff generated from the site. A stormwater maintenance agreement will be required with the final plat. A grading permit shall not be issued until the final plans have been approved by the city in conjunction with the final plat. Drainage leaving the site must fall within a drainage and utility easement accessible to the development. The final grading plan shall identify all fill lots where building footings will be placed on fill material. Grading specifications shall indicate that all embankments meet FHA/HUD 79G requirements. Building permits will not be issued until a soils report and an as-built certified grading plan have been submitted and approved by City staff. The proposed development will disturb more than one acre of land. A National Pollutant Discharge Elimination System (NPDES) Construction Permit is required from the Minnesota Pollution Control Agency (MPCA). A copy of the Notice of Stormwater Permit Coverage shall be submitted to the City prior to construction. Development of Prime 35 Industrial includes construction of public storm sewer systems to collect and convey runoff within public right-of-way. Privately owned and maintained storm sewer shall be constructed to collect and convey runoff from within the private lots. All storm sewer systems shall be designed and constructed in accordance with City standards. Draintile construction is required in areas of non-granular soils for the street sub-cuts and lots. Any additional draintile construction, including perimeter draintile required for building footings, which is deemed necessary during construction shall be the developer’s responsibility to install and finance. The Storm Sewer Charge has not been collected on the parent parcel and shall be paid with the final plat. Prime 35 Industrial is located within areas shown on the Flood Insurance Rate Map (Map No. 27037C0194E) primarily as Zone X and is identified as Zone AE along the northeast quadrant PPRRIIMMEE 3355 IINNDDUUSSTTRRIIAALL –– PPRREELLIIMMIINNAARRYY PPLLAATT FFEEBBRRUUAARRYY 2233,, 22002266 PPAAGGEE 55 OOFF 55 of the plat as determined by FEMA. Based on this designation, a portion of the site is located within the plat is located within a Special Flood Hazard Area (SFHA). No buildings or grading are being proposed within the SFHA. A wetland delineation for the site was approved June 18, 2025. A wetland replacement plan was submitted and is out for comment until March 5, 2026. The replacement identifies 2 acres of wetland impacts to previously farmed wetlands. A preapplication meeting was held with the TEP prior to the replacement plan being set out on notice. The replacement plan was updated based on comment from TEP. A decision will be made on the replacement plan on or before March 3, 2026. No impacts can take place to the wetland prior to approval of the wetland replacement plan and purchase of wetland credit to offset the impacts. All wetlands, waterways, floodplains and buffers will be placed in City owned outlots with final plat. Natural Area signs will be installed along City owned outlots by the developer. The tree removal threshold for the Prime 35 site is 70%. The tree preservation plan dated 11/14/2025 identifies 26,566 inches of existing significant diameter inches on the property and proposes the removal of 18,339 significant diameter inches, or 69%. Heritage trees were not calculated separately. Per the tree preservation ordinance, all diameter inches of heritage trees removed shall require replacement. The Tree Preservation Plan is to be updated to calculate the number of diameter inches of Heritage Trees onsite, to be removed, and to be preserved; and to provide an updated summary table indicating the number of tree inches that require replacement. A calculation worksheet is available on the City’s website. The Developer is responsible for obtaining an MPCA Construction Permit for the site prior to construction. The permit requires that all erosion and sediment BMPS be clearly outlined in a site’s SWPPP. Changes made throughout construction must be documented in the SWPPP. A final SWPPP must be submitted to the City for review and approval prior to any land disturbing activity. Additional erosion control measures may be required during construction as deemed necessary by City staff. Any additional measures required shall be installed and maintained by the developer. Engineering recommends approval of the Prime 35 Industrial preliminary plat, grading and erosion control plan, and utility plan, subject to the requirements and stipulations within this report.     ! "#$ Legal Description: The East one-half of the Southeast Quarter of Section Thirty-six (36), Township One-Hundred Fourteen (114), Range Twenty-one (21) and the West one-half of the Southwest Quarter of Section Thirty-one (31), Township One Hundred Fourteen (114), Range Twenty (20), except that part thereof described as follows: The West 409.31 feet of the North 887.00 feet of the Northwest Quarter of the Southwest Quarter of Section Thirty-one (31), Township One Hundred Fourteen (114), Range Twenty (20) and further except the East 81.79 feet of the North 887.00 feet of the Northeast Quarter of the Southeast Quarter of Section Thirty-six (36), Township One Hundred Fourteen (114), Range Twenty-one (21), Dakota County, Minnesota. PROPERTY DESCRIPTION PROJECT NO. 24306-00 CAD FILE 11/07/2025 DATE REVISIONS DRAWN BY 24306PP.dwg F: \ _ C i v i l 3 D P r o j e c t s \ 2 4 3 0 6 \ P R E - P L A T P L A N S \ 2 4 3 0 6 p p . d w g - 2 / 0 9 / 2 0 2 6 0 4 : 0 2 P M PLM SCALE IN FEET 0 100 200 ZONING INFORMATION I-1 (LIGHT INDUSTRIAL DISTRICT)CURRENT ZONING: PROPOSED ZONING:I-1 (LIGHT INDUSTRIAL DISTRICT) LOTS LOTS R.O.W. C.S.A.H. NO. 70 (215TH STREET WEST) 215TH STREET WEST JAVELLIN AVENUE 217TH STREET WEST OUTLOTS TOTAL 8 LOTS 100.39 ACRES 8.50 ACRES (1.61 ACRES) (0.94 ACRES) (0.61 ACRES) (5.34 ACRES) 36.32 ACRES 145.21 ACRES MINIMUM SETBACKS (PARKING) FRONT SIDE (INTERIOR) SIDE (STREET) REAR 15 FEET 5 FEET 15 FEET 5 FEET SITE DATA GROSS AREA 145.21 ACRES MINIMUM LOT REQUIREMENTS LOT AREA LOT WIDTH 30,000 S.F. 100 FEET LA K E V I L L E , M I N N E S O T A PR I M E 3 5 L A K E V I L L E OL A M H O L D I N G S 1 , L L C FO R 26 8 B U S H S T R E E T , # 4 9 , S A N F R A N C I S C O , C A 9 4 1 0 4 PR E L I M I N A R Y P L A T 29 9 9 W E S T C . R . 4 2 , S U I T E 1 0 0 BU R N S V I L L E , M N 5 5 3 0 6 PH O N E : 9 5 2 - 8 9 0 - 6 0 4 4 ma r c u s @m n h i l l . c o m ww w . m n h i l l . c o m Da t e : Re g . N o . I h e r e b y c e r t i f y t h a t t h i s s u r v e y , p l a n or r e p o r t w a s p r e p a r e d b y m e o r un d e r m y d i r e c t s u p e r v i s i o n a n d t h a t I am a d u l y L i c e n s e d L a n d S u r v e y o r un d e r t h e l a w s o f t h e S t a t e o f Mi n n e s o t a . PRE L I M I N A R Y MINIMUM SETBACKS (BUILDING) FRONT SIDE (INTERIOR) SIDE (STREET) REAR 40 FEET 10 FEET 30 FEET 30 FEET C200 DRAINAGE AND UTILITY EASEMENTS BEING 5 FEET IN WIDTH, UNLESS OTHERWISE INDICATED, ADJOINING LOT LINES, AND BEING 10 FEET IN WIDTH, UNLESS OTHERWISE INDICATED, ADJOINING RIGHT OF WAY LINES, AS SHOWN ON THIS PLAT. DRAINAGE AND UTILITY EASEMENTS ARE SHOWN THUS:2026-01-20 CITY COMMENTS G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G X X X X X X X X X X X X X XXXXXXXXX X X X X X X X X X X X X XXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP X X X X X X X X X X X X X X X X X X X X X X >> > > > > > >> > I I I I I I I I I I E E E E E E E E E E E E E E T T T T T T T T T T T T T T T II HWL HWL HWL HWL HWL HWL HWL HWL HWL HWL HW L HW L HW L HW L HWL HWL HWL HW L HW L HW L HWL HWL HWL HWL HWL HWL HWL HWL HWL HWL HW L HWL HW L HWL HWL HWL HW L HWL HW L HWL HW L HWL HWL HWL HW L HWL HWL HWL HWL HWL HWL HWL HW L HW L WETLAND 1 3.12 AC MANAGE 1 WETLAND 2 0.96 AC MANAGE 1 WETLAND 3 0.07 AC MANAGE 1 WETLAND 4 0.07 AC MANAGE 2 WETLAND 7 0.04 AC MANAGE 2 WETLAND 5 1.89 AC UTILIZE 215TH STREET W (C.R. 70) 217TH STREET 215TH STREET 8" SANITARY STUB INV 1015.35 (PER PLAN) TEMPORARY HYDRANT 1024 1026 1028 1030 1032 1034 1036 1038 1040 104 2 1044 104 6 1048 1050 1052 1054 1056 1058 1060 1062 1064 1066 1068 1070 1072 1074 1076 10 2 2 10 2 4 10 2 6 10 2 8 103 0 10321034 1036 10 3 8 1040 104 4 104 2 104 0 103 8 1036 103 4 1032 1030 1028 1026 1026 1024 1022 1020 1018 1014 1018 10161020 1022 1018 1018 1018 102 0 10 3 0 10 2 2 10 2 4 10 2 6 10 2 8 10 3 2 10 4 0 10 5 0 10 6 0 10 4 2 10 4 4 10 4 6 10 4 8 10 5 2 10 5 4 10 5 6 10 5 8 1042 1044 1046 1048 1050 1052 1054 1056 1058 1060 1062 1064 10 5 0 10 6 0 10 7 0 1040 103 0 104 0 10 5 0 10 6 0 1028 103 0 103 2 103 4 103 6 10 3 8 10 4 0 105 0 1060 1068 1070 1072 1074 1076 1078 1080 1082 1084 1080 1080 1086 1078 1060 1050 1040 1034 1032 1030 1040 1038 1036 1034 1052 1054 1056 1058 1048 1046 1040 1050 1060 1070 1070 1080 1080 1034 1036 1038 1042 1044 1046 1048 1052 1054 1056 1058 1062 1064 1066 1066 106 8 1068 1072 1072 1074 1074 1076 1076 1078 1078 1082 1082 1084 1084 103 6 1038 104 0 1042 1042 1042 1040 GASMAIN EASEMENT (NORTHERN NATURAL GAS) EX SSMH RIM 1039.18 INV 1013.93 (PER AS-BUILT) 12" PVC WM WEST B R A N C H S O U T H C R E E K WETLAND 6 0.19 AC UTILIZE WETLAND 8 0.34 AC MANAGE 1 FLOODPLAIN ZONE AE PER FEMA MAPS. BASE FLOOD ELEVATION = 1024.0 EX FES INV 1013.56 EX 85 LF 30" RCP @ 0.49% EX FES INV 1013.15 PROJECT NO. 24306 CAD FILE 11/14/25 DATE REVISIONS DRAWN BY Da t e : Re g . N o . 29 9 9 W E S T C . R . 4 2 , S U I T E 1 0 0 BU R N S V I L L E , M N 5 5 3 0 6 PH O N E : 9 5 2 - 8 9 0 - 6 0 4 4 bb u s s e l m a n @m n h i l l . c o m ww w . m n h i l l . c o m PRE L I M I N A R Y LA K E V I L L E , M I N N E S O T A PR I M E 3 5 L A K E V I L L E OL A M H O L D I N G S 1 , L L C FO R 26 8 B U S H S T R E E T , # 4 9 , S A N F R A N C I S C O , C A 9 4 1 0 4 F: \ _ C i v i l 3 D P r o j e c t s \ 2 4 3 0 6 \ P R E - P L A T P L A N S \ 2 4 3 0 6 E X C . d w g - 2 / 0 9 / 2 0 2 6 0 4 : 0 2 P M EXISTING CONTOUR923 24306EXC EX I S T I N G C O N D I T I O N S EPF LEGEND > I > I OHP OHP X X X X G G G E E E UFO UFO UFO T T T EXISTING TELEPHONE PEDESTAL EXISTING TRANSFORMER EXISTING LIGHT POLE EXISTING TREELINE/TREES EXISTING STORM SEWER EXISTING SANITARY SEWER EXISTING WATERMAIN EXISTING OVERHEAD POWER LINE EXISTING CURB & GUTTER EXISTING FENCE EXISTING ASPHALT EXISTING CONCRETE EXISTING UNDERGROUND GAS EXISTING UNDERGROUND ELECTRIC EXISTING UNDERGROUND FIBER OPTIC EXISTING UNDERGROUND TELEPHONE EXISTING TV PEDESTAL EXISTING SOIL BORING LOCATION S TV T EXISTING MANHOLE (ELECTRIC) EXISTING SIGN EXISTING VAULT E V SB-1 Know what's below. before you dig.Call R SCALE IN FEET 0 100 200 C102 EXISTING WETLAND EDGE EXISTING WETLAND NOTES WETLAND DELINEATION COMPLETED IN JUNE, 2025 BY KIMLEY-HORN AND ASSOCIATES, INC. PRELIMINARY WETLAND QUALITY LEVELS DETERMINED BY KJOLHAUG ENVIRONMENTAL. EXISTING CONDITIONS ARE BASED ON ALTA SURVEY PREPARED BY EGAN, FIELD AND NOWAK, INC., DATED DECEMBER 11, 2024. FEMA FLOODPLAIN I h e r e b y c e r t i f y t h a t t h i s s u r v e y , p l a n or r e p o r t w a s p r e p a r e d b y m e o r un d e r m y d i r e c t s u p e r v i s i o n a n d t h a t I am a d u l y L i c e n s e d L a n d S u r v e y o r un d e r t h e l a w s o f t h e S t a t e o f Mi n n e s o t a . G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP >> > > > > > >> > I I I I I I I I I I E E E E E E E E E E E E E E T T T T T T T T T T T T T T T II HWL HWL HWL HWL HWL HWL HWL HWL HWL HWL HW L HW L HW L HW L HWL HWL HWL HW L HW L HW L HWL HWL HWL HWL HWL HWL HWL HWL HWL HWL HW L HWL HW L HWL HWL HWL HW L HWL HW L HWL HW L HWL HWL HWL HW L HWL HWL HWL HWL HWL HWL HWL HW L HW L R20'R20' R15' R3' R3' R15' R3'R3' R12'R12' 55 ' TY P . 12' TYP. 20 ' TY P . 24 ' 20 ' TY P . 9' TYP. 24' F-F 9' TYP.20 ' TY P . 24 ' 20 ' TY P . 19 . 2 ' 20 ' TY P . 24 ' 20 ' TY P . R3' R3' R48 ' R24' R3' R3' R3' R3' R3' R24' R12' R20 ' R20 ' R3' R3' R15' R15' R3' R3' R48' R24 ' R3' R3' 13 0 ' 30 ' F- F 24 ' F- F 20' TYP.24' 20' TYP. 9' TY P . 20' TYP.24' 20' TYP. 9' TY P . 20 ' TY P . 24 ' 20 ' TY P . 9' TYP. 9' TYP. 20' TYP. 24' 20' TYP. 20' TYP. 24' 20' TYP. 9' TY P . 9' TY P . 600' 28 0 ' 580' 12 0 ' R48 ' R24' R3' R3' R3' R3' R3'R3' R15' R3'R3' R9' R48' R20 ' R20' R25 ' 20 ' TY P . 24 ' 20 ' TY P . 9' TYP. 9' TYP. 20 ' TY P . 24 ' 20 ' TY P . 9' TYP. 9' TYP. 20' TYP.24' 20' TYP. 9' TY P . 9' TY P . 13 0 ' 18 5 ' 40 ' 55 ' 12' TYP. 502' 21 2 ' 14 11 R24 . 2 ' R48' R24 ' R48 ' R2 0 ' R20' R15 ' R6' R3 ' R3' R3' R3' R15 ' R15' R3' R4 8 ' R3' R9' R9'R9'R3' R3' R2 4 ' R3' R15 ' R15'R15 ' R3' R15' R3' R3' R3' R45' R45 ' R3 ' R3' R3 ' R3' R25 ' R15' R24' R15' R3 ' R3' R1 5 ' R3' R3' R3' R9' R3' R9' R3' R9' R24' R3' R3 ' R24 ' R3' R3 ' R20' R24' R3 ' R3' R3' R3 ' R24' R3' R3 ' R24' R48' 20' TYP.24' 20' TYP. 9'TY P . 9'TY P . 20' TYP.24' 20' TYP. 24' F-F 60 'F-F 20' TYP.24' 20' TYP. 9'TY P . 20 ' TY P . 24 ' 20 'TY P . 9' TYP. 9' TYP. 20 'TY P . 24 ' 20 ' TY P . 9' TYP. 9' TYP. 55' 12 'TY P . 125' 650' 210 ' 13 0 ' 20 ' TY P . 24 ' 20 'TY P . 9' TYP. 9' TYP. 20 ' TY P . 24 ' 20 ' TY P . 9' TYP. 9' TYP. 20 'TY P . 24 ' 20 ' TY P . 9' TYP. 9' TYP. 952' 210 ' 20 0 ' 20' TYP.24' 20' TYP. 9'TY P . 9'TY P . 60 'F-F R3 ' R3' R3' R3 ' 20' TYP.24' 20' TYP. 9'TY P . 9'TY P . 952' 24' F-F 24' F-F 70' 26 0 ' 20' TYP.24' 20' TYP. 9'TY P . 9'TY P . 23.6' 125' 55' 70' 12 'TY P . 24 ' F-F R2 0 ' R24 ' R4 8 'R9' R3' R3 ' R3' R2 4 ' R3' R3' R3' R3' 28' F-F 24 'F-F 28' F-F 30 'F-F 24 'F-F 24' F-F 20 ' 24 ' 20 ' 9' TYP. 9' TYP. 20 'TY P . 24 ' 20 ' TY P . 9' TYP. 9' TYP. 20 'TY P . 24 ' 20 ' TY P . 20' TYP.24' 20' TYP. 9'TY P . 9'TY P . R3' R3'R3' R3' R20' R3' R3'R3' R3'R85' R3' R3' R3 ' 20 'TY P . 24 ' 20 ' TY P . 20 ' TY P . 24 ' 20 ' TY P . 9' TYP. 9' TYP. 30 'F-F 24 'F-F 210' 47 6 ' 55' 130'12 'TY P . 60' F-F 30 'F-F R25 ' R15'R9' R3' R15 ' R3' R3' R3'R3' R3' R3 'R15 ' R15' R3'R15 ' R3 ' R15'R3' R15' R30 6 . 5 ' R24 ' R10 ' R3' R3 ' 28 ' F- F 24' F-F 64.5' 55'175' 55'175' 20' TYP.24' 20' TYP. 9' TY P . 9' TY P . 20 ' TY P . 24 ' 20 ' TY P . 9' TYP. 9' TYP. 20 ' TY P . 24 ' 20 ' TY P . 55' 12 ' TY P . 12 ' TY P . 12 ' TY P . 55' 12 ' TY P . 20 ' TY P . 20 ' TY P . 9' TYP. 20 ' TY P . 9' TYP. 55' TYP. 12 ' TY P . 175' 55' TYP. 12 ' TY P . 10 7 . 5 ' 53 1131 11 11 12 26 34 53 53 26 32 36 38 30 30 52 80 52 26 36 30 36 38 52 118 52 72 71 35 27 27 27 58 58 30 30 67 67 30 3 19 27 64 35 30 0 ' 30 0 ' 11 0 ' 60 ' R48 ' R36' R64' R64' 30'24' 10 2 ' 262' 70' 55 0 ' 122' R15' R15' R15' R10' R10' R10' R10 ' PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PS L PS L PS L PS L PS L PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PS L PS L PS L PS L PS L PS L BS L BS L BS L BS L BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BS L BS L BS L BS L BS L BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PS L PS L PS L PS L PS L PS L PS L PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PS L PS L PS L PS L PS L PS L PSL PSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BS L BS L BS L BS L BS L BS L BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BS L BS L BS L BS L BS L BSL BSL PS L PS L PSL PSL PSL PSL PSL PS L PS L PS L PS L PS L PS L PS L PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L BSLBSL BSL BSL BSL BSL BS L BS L BS L BS L BS L BS L BS L BS L BS L BS L BSL BSL BSL BSL BSL BS L BS L BS L BS L BS L BS L BS L BSL BSL BSL PS L PS L PS L PS L PS L PS L PS L PSL PSL PSL PSL PSL PSL PSL PSL PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PSL PSL PSL PS L PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSLPSL PSL PSL PSL PSL PSL PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PSLPSLPSLPSLPSLPSLPSLPSL PSL PSL PSL PS L PS L PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL BS L BS L BS L BS L BS L BS L BS L BS L BSLBSLBSLBSLBSLBSLBSLBSL BSL BSL BS L BS L BS L BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL PSL PSL PSL PSL PSL PS L PS L PS L PS L PS L PS L PS L PS L PSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSL PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PSL PSL PSL PSL PSL PSL BSL BSL BSL BSL BSL BS L BS L BS L BS L BS L BS L BS L BSLBSLBSLBSLBSLBSLBSLBSLBSLBSLBSL BS L BS L BS L BS L BS L BS L BS L BS L BS L BS L BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BS L BS L BSL BSL BS L BS L BSL BS L BSL BSL BS L BS L BS L BSLBSLBSLBSLBSLBSLBSLBSLBSLBSLBSLBSL BS L BS L BS L BS L BS L BS L BS L BS L BS L BS L BS L BS L BS L BSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSL PSLPSL PSL PS L PSL PSL PSL PSL PSL PSL PSL PSL PSLPSL PSL PSL PSL PSL PSL PSL PSL PSL PS L PS L PS L PS L PS L PS L PS L BUILDING 2 168,000 SF TOTAL BUILDING 3 106,424 SF TOTAL BUILDING 8 93,824 SF TOTAL BUILDIN G 7 99,960 S F T O T A L BUILDIN G 6 247,520 S F T O T A L BUILDIN G 5 199,920 S F T O T A L BUILDIN G 4 136,500 S F T O T A L BUILDING 1 69,600 SF TOTAL 300' RIGHT TURN LANE180' TAPER 12 ' 12 ' 12 ' PROPOSED BITUMINOUS EXTENSION 4' 215TH STREET WEST (CR70) 217TH STREET WEST 215TH STREET WEST MAINTENANCE BUILDING 15,500 SF TRAILER STORAGE TRAILER STORAGE TRAILER STORAGE TRAILER STORAGE TRAILER STORAGE TRAILER STORAGE TRAILER STORAGE TRAILER STORAGE TRAILER STORAGE TRAILER STORAGE BSL BSL BSL BS L BS L BS L BS L BS L BS L BS L BS L BS L BS L BS L BS L BS L BS L BSL BSL BSL BSL BSL BSL BSL BSL BSL BS L BS L BS L BS L BS L BS L BS L BS L BS L BS L BS L BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL R15' R15 'R52 ' R76' R48 ' R10.5' R4 5 ' R6 0 ' R60' R84' R25' 13 0 ' 30' R90' R120' R90' R60' R15' R3 ' 30 ' R20' R10 ' BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSLBSL BSL BS L BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BSL BS L BS L BS L BS L BS L BS L BS L PSL PSL PSL PSL PSL PSL PSL PS L PS L PSL PSL PS L PSL PS L PSL PSL PS L PS L PS L PS L PSL PSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSL PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PS L PSL R15' R3 'R3' R3 . 5 ' R3. 5 ' R25' R25 ' R25' R25 ' R25 ' R25' R25'R25 ' R25' R2 5 ' R24' R25' R2 5 ' R25' R20' R25 ' R25' R326' R4 5 ' R4 5 ' R20 ' PROPOSED 10' BITUMINOUS TRAIL 10 ' 10 ' EXISTING CONTOUR923 LEGEND PROPOSED CONCRETE PROPOSED BITUMINOUS SURFACE PROPOSED SEDIMENT BASIN PROPOSED INFILTRATION BASIN PROPOSED WATERMAINII PROPOSED SANITARY SEWER PROPOSED STORM SEWER>> PROPOSED CURB & GUTTER PROPOSED SANITARY SERVICE PROPOSED WATER SERVICE > I > I OHP OHP X X X X G G G E E E UFO UFO UFO T T T EXISTING TELEPHONE PEDESTAL EXISTING TRANSFORMER EXISTING LIGHT POLE EXISTING TREELINE/TREES EXISTING STORM SEWER EXISTING SANITARY SEWER EXISTING WATERMAIN EXISTING OVERHEAD POWER LINE EXISTING CURB & GUTTER EXISTING FENCE EXISTING ASPHALT EXISTING CONCRETE EXISTING UNDERGROUND GAS EXISTING UNDERGROUND ELECTRIC EXISTING UNDERGROUND FIBER OPTIC EXISTING UNDERGROUND TELEPHONE EXISTING TV PEDESTAL EXISTING SOIL BORING LOCATION S TV T EXISTING MANHOLE (ELECTRIC) EXISTING SIGN EXISTING VAULT E V SB-1 PROPOSED CONTOUR923 EXISTING WETLAND EDGE EXISTING WETLAND SHORELAND ZONING OVERLAY PSL PSL PSL BSL BSL BSL BUILDING SETBACK PARKING SETBACK PROPOSED FILTRATION BASIN PROJECT NO. 24306 CAD FILE 11/14/25 DATE REVISIONS DRAWN BY Da t e : Re g . N o . 2026-01-20 CITY COMMENTS 29 9 9 W E S T C . R . 4 2 , S U I T E 1 0 0 BU R N S V I L L E , M N 5 5 3 0 6 PH O N E : 9 5 2 - 8 9 0 - 6 0 4 4 bb u s s e l m a n @m n h i l l . c o m ww w . m n h i l l . c o m I h e r e b y c e r t i f y t h a t t h i s p l a n , sp e c i f i c a t i o n o r r e p o r t w a s p r e p a r e d b y me o r u n d e r m y d i r e c t s u p e r v i s i o n a n d th a t I a m a d u l y L i c e n s e d P r o f e s s i o n a l En g i n e e r u n d e r t h e l a w s o f t h e S t a t e o f Mi n n e s o t a . PRE L I M I N A R Y LA K E V I L L E , M I N N E S O T A PR I M E 3 5 L A K E V I L L E OL A M H O L D I N G S 1 , L L C FO R 26 8 B U S H S T R E E T , # 4 9 , S A N F R A N C I S C O , C A 9 4 1 0 4 2026-02-10 CITY COMMENTS 24306SITE OV E R A L L S I T E & D I M E N S I O N A L P L A N Know what's below. before you dig.Call R SCALE IN FEET 0 100 200 VUN C600 F: \ _ C i v i l 3 D P r o j e c t s \ 2 4 3 0 6 \ P R E - P L A T P L A N S \ 2 4 3 0 6 S I T E . d w g - 2 / 0 9 / 2 0 2 6 0 4 : 0 4 P M DEVELOPMENT SUMMARY GROSS PROJECT AREA 145.21 AC R.O.W.8.50 AC C.S.A.H. NO. 70 (215TH STREET WEST)(1.61 AC) 215TH STREET WEST (0.94 AC) JAVELLIN AVENUE (0.74 AC) 217TH STREET WEST (5.21 AC) OUTLOTS 36.32 AC LOTS (8 TOTAL)100.39 AC TOTAL 145.21 AC MINIMUM BUILDING SETBACKS FRONT YARD 40 FEET INTERIOR SIDE YARD 10 FEET STREET SIDE YARD 30 FEET REAR YARD 30 FEET MINIMUM PARKINGS SETBACKS FRONT YARD 15 FEET INTERIOR SIDE YARD 5 FEET STREET SIDE YARD 15 FEET REAR YARD 5 FEET ZONING I-1, LIGHT INDUSTRIAL DISTRICT MAXIMUM BUILDING HEIGHT THE LESSER OF: FOUR (4) STORIES OR 50' FEET MAXIMUM IMPERVIOUS COVERAGE 75% (SHORELAND AREA ONLY) BUILDING GROSS FLOOR AREA (8 BUILDINGS)1,112,748 SF SITE PLAN NOTES 1.SEE GENERAL NOTES, SHEET C101, FOR ADDITIONAL RELEVANT INFORMATION. G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP >> > > > > > >> > I I I I I I I I I I E E E E E E E E E E E E E E T T T T T T T T T T T T T T T II HWL HWL HWL HWL HWL HWL HWL HWL HWL HWL HW L HW L HW L HW L HWL HWL HWL HW L HW L HW L HWL HWL HWL HWL HWL HWL HWL HWL HWL HWL HW L HWL HW L HWL HWL HWL HW L HWL HW L HWL HW L HWL HWL HWL HW L HWL HWL HWL HWL HWL HWL HWL HW L HW L > > > > > > > > >>>> > > >> > > > > >>> > > > > > > > > > > > > > > > > > > > > >> > > > > > > > > > > > > > > > > > > > > > > >>> > > > > > >> > > > > > >> >> > > > > > > >>>>>> IIIII I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I III II I I I I I I I I I I I I I I I I I I I I I I IIIIII I I I I I I I I I > > > > IIIIIIIIII I I IIIII I I I I IIII I I I I I I I I I I I I I I I I I I I I IIIIIII I I > > >>>>>>>>>>>>>>>>>>>>>> >> >> >> >> >>>> > >> > > > >>>>>>> > >> >> FFE=1041.00 BUILDING 1 FFE=1041.75 BUILDING 2 FFE=1047.00 BUILDING 3 FFE=1055.50 BUILDING 8 FFE=107 5 . 0 0BUILDIN G 7 FFE=107 5 . 0 0BUILDIN G 5 FFE=107 5 . 0 0BUILDIN G 6 FFE=106 4 . 5 0BUILDIN G 4 1040 1062 1066 1066 1060 1060 1070 1070 1072 106 8 10 7 0 107 2 1070 1040 10501060 1070 1068 1072 1050 105 0 1048 1046 1044 1050 1030 10401042 10361036 1036 1040 1070 1036 103 6103 6 1040 10 3 6 10 3 2 10 6 0 1020 1030 1038 1070 10501060 1040 1042 10 3 8 10 3 8 1024 1026 1028 1030 1032 1034 1036 1038 1040 104 2 1044 104 6 1048 1050 1052 1054 1056 1058 1060 1062 1064 1066 1068 1070 1072 1074 1076 10 2 2 10 2 4 10 2 6 10 2 8 103 0 10321034 1036 10 3 8 1040 104 4 104 2 104 0 103 8 1036 103 4 1032 1030 1028 1026 1026 1024 1022 1020 1018 1014 1018 10161020 1022 1018 1018 1018 102 0 10 3 0 10 2 2 10 2 4 10 2 6 10 2 8 10 3 2 10 4 0 10 5 0 10 6 0 10 4 2 10 4 4 10 4 6 10 4 8 10 5 2 10 5 4 10 5 6 10 5 8 1042 1044 1046 1048 1050 1052 1054 1056 1058 1060 1062 1064 10 5 0 10 6 0 10 7 0 1040 103 0 104 0 10 5 0 10 6 0 1028 103 0 103 2 103 4 103 6 10 3 8 10 4 0 105 0 1060 1068 1070 1072 1074 1076 1078 1080 1082 1084 1080 1080 1086 1078 1060 1050 1040 1034 1032 1030 1040 1038 1036 1034 1052 1054 1056 1058 1048 1046 1040 1050 1060 1070 1070 1080 1080 1034 1036 1038 1042 1044 1046 1048 1052 1054 1056 1058 1062 1064 1066 1066 106 8 1068 1072 1072 1074 1074 1076 1076 1078 1078 1082 1082 1084 1084 103 6 1038 104 0 1042 1042 1042 1040 1022 1028 10 2 4 10 2 0 103 0 104 0 10 5 0 10 4 8 1052 1054 1054 1020 1030 1018 1022 1024 1026 1028 1032103410361038 10 3 0 10 3 2 10 3 4 10 3 6 10 3 8 1038 1036 1034 1032 1032 1034 10 3 6 10 3 4 1032 10201022 1020 1048 1046 10401042 1038 2:1 2:1 2:1 1038 1028 103 0 103 2 COORDINATE WITH ADJACENT PROPERTY TO ALLEVIATE RETAINING WALL 1044 104010461042 1048 1040 1040 1030 1040 1050 1060 107 0 102810281026 1026 10 2 0 10 2 2 10 2 4 10 3 0 10 3 0 10 2 0 10 2 4 10 2 8 10 2 4 10 3 0 10 4 0 10 3 0 10 4 0 106 2 1064 1066 1064 INFILTRATION BASIN 7P BOTTOM=1026.00 OLE=1027.80 10 YEAR HWL=1027.92 100 YEAR HWL=1028.36 INFIL. CAPACITY=406,823 CF PRE-TREATMENT BASIN 3P NWL=1026.00 (BYPASS)OLE=1027.80 10 YEAR HWL=1028.00 100 YEAR HWL=1029.02 DEAD STORAGE=293,594 CF PRE-TREATMENT BASIN 4P NWL=1032.00 (BYPASS)OLE=1033.50 10 YEAR HWL=1034.02 100 YEAR HWL=1036.15 DEAD STORAGE=557,568 CF INFILTRATION BASIN 1Pi BOTTOM/NWL=1029.00 OLE=1030.50 10 YEAR HWL=1030.68 100 YEAR HWL=1032.03 INFIL. CAPACITY= 65,126 CF FILTRATION BASIN 6P BOTTOM=1018.50 OLE=1020.00 10 YEAR HWL=1020.01 100 YEAR HWL=1020.67 FILTRATION CAPACITY=15,704 CF 106 0 215TH STREET WEST (CR70) 217TH STREET WEST 215TH STREET WEST REQUIRED AVERAGE WETLAND BUFFER = 35' REQUIRED BUFFER AREA = 39,073 SF PROVIDED BUFFER AREA = 39,872 SF MIN BUFFER LENGTH PROVIDED = 25' EXISTING BUFFER AREA CULTIVATED PROPOSED VEGETATION TO MEET NATIVE BUFFER ERQUIREMENTS 100' WIDE CREEK BUFFER WEST BRA N C H S O U T H C R E E K 1050 10 6 0 1070 1068 10 8 0 10 7 0 107 0 1036 1036 1034 1032 1030 1028102610241022 1038 1036 1034 1032 1030 104 0 1030 1032 1034 10 4 8 1024 1026 1030 1040 1026 1040 1036 1034 1032 1030 1028 1026104210441046 10 2 0 10 2 2 10 2 4 217TH S T R E E T W E S T 10 3 0 10 4 0 10 5 0 106 0 105 8 PRETREATMENT BASIN 1P BOTTOM=1022.00 NWL=1029.00 OLE=1030.50 10 YEAR HWL=1031.00 100 YEAR HWL=1032.30 10 5 0 10 6 0 10 4 4 10 4 6 10 4 8 10 5 2 10 5 4 10 5 6 10 5 8 10 6 2 10 6 4 10 6 6 10 4 4 10 5 0 10 6 0 10 4 4 10 4 6 10 4 8 10 5 2 10 5 4 10 5 6 10 5 8 1042 1044 10461048 PROJECT NO. 24306 CAD FILE 11/14/25 DATE REVISIONS DRAWN BY Da t e : Re g . N o . 2026-01-20 CITY COMMENTS 29 9 9 W E S T C . R . 4 2 , S U I T E 1 0 0 BU R N S V I L L E , M N 5 5 3 0 6 PH O N E : 9 5 2 - 8 9 0 - 6 0 4 4 bb u s s e l m a n @m n h i l l . c o m ww w . m n h i l l . c o m I h e r e b y c e r t i f y t h a t t h i s p l a n , sp e c i f i c a t i o n o r r e p o r t w a s p r e p a r e d b y me o r u n d e r m y d i r e c t s u p e r v i s i o n a n d th a t I a m a d u l y L i c e n s e d P r o f e s s i o n a l En g i n e e r u n d e r t h e l a w s o f t h e S t a t e o f Mi n n e s o t a . PRE L I M I N A R Y LA K E V I L L E , M I N N E S O T A PR I M E 3 5 L A K E V I L L E OL A M H O L D I N G S 1 , L L C FO R 26 8 B U S H S T R E E T , # 4 9 , S A N F R A N C I S C O , C A 9 4 1 0 4 2026-02-10 CITY COMMENTS EXISTING CONTOUR923 24306G GR A D I N G & D R A I N A G E P L A N EPF LEGEND PROPOSED CONCRETE PROPOSED BITUMINOUS SURFACE PROPOSED SEDIMENT BASIN PROPOSED INFILTRATION BASIN PROPOSED WATERMAINII PROPOSED SANITARY SEWER PROPOSED STORM SEWER>> PROPOSED CURB & GUTTER PROPOSED SANITARY SERVICE PROPOSED WATER SERVICE > I > I OHP OHP X X X X G G G E E E UFO UFO UFO T T T EXISTING TELEPHONE PEDESTAL EXISTING TRANSFORMER EXISTING LIGHT POLE EXISTING TREELINE/TREES EXISTING STORM SEWER EXISTING SANITARY SEWER EXISTING WATERMAIN EXISTING OVERHEAD POWER LINE EXISTING CURB & GUTTER EXISTING FENCE EXISTING ASPHALT EXISTING CONCRETE EXISTING UNDERGROUND GAS EXISTING UNDERGROUND ELECTRIC EXISTING UNDERGROUND FIBER OPTIC EXISTING UNDERGROUND TELEPHONE EXISTING TV PEDESTAL EXISTING SOIL BORING LOCATION S TV T EXISTING MANHOLE (ELECTRIC) EXISTING SIGN EXISTING VAULT E V SB-1 Know what's below. before you dig.Call R SCALE IN FEET 0 100 200 C400 PROPOSED CONTOUR923 EXISTING WETLAND EDGE EXISTING WETLAND F: \ _ C i v i l 3 D P r o j e c t s \ 2 4 3 0 6 \ P R E - P L A T P L A N S \ 2 4 3 0 6 G . d w g - 2 / 0 9 / 2 0 2 6 0 4 : 0 3 P M PROPOSED FILTRATION BASIN 215TH STREET WEST OFF-PROPERTY PR O P E R T Y L I N E PR O P E R T Y L I N E MA T C H L I N E - S H E E T L 1 0 1 MA T C H L I N E - S H E E T L 1 0 2 MATCH LINE - SHEET L101 MATCH LINE - SHEET L103 MA T C H L I N E - S H E E T L 1 0 3 MA T C H L I N E - S H E E T L 1 0 4 MATCH LINE - SHEET L102 MATCH LINE - SHEET L104 PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E 215TH STREET WEST LANDSCAPE OVERVIEW PLAN: 1. See Civil Engineer's plans for site plan layout and dimensions. 2. Contractor to coordinate any work in the city right-of-way with City of Lakeville Public Works Department. 3. See Architect's plans for additional requirements regarding the site plan layout. 4. Place a minimum of 4" topsoil or slope dressing on all areas disturbed by construction, including right-of-way boulevards, unless specified otherwise. 5. See Civil Engineer's Plans for utility locations. 6. Irrigation plan to be design-build by landscape contractor. CITY OF LAKEVILLE LANDSCAPE REQUIREMENTS: GENERAL NOTES: DE S I G N G R O U P La n d s c a p e A r c h i t e c t u r e | P l a n n i n g 11-21-9: REQUIRED SCREENING AND LANDSCAPING: B: Landscaping: Required landscaping for new residential subdivisions and commercial, industrial or institutional uses shall include plantings at the property perimeter, off street parking perimeter landscaping and interior landscape plantings as well as required residential buffer yard or transitional buffer zone plantings. ZONING INFORMATION: I-2 - General Industrial District PARKING LOT SCREENING: Parking lots with more than 5 spaces require screening. Landscape screening shall be set back 2' from the parking stalls. Deciduous trees shall be planted no more than 40 apart. Evergreen trees shall be planted so that branches are touching at narrowest mature canopy width. Large deciduous shrubs shall be planted so that branches are touching at narrowest projected mature width. MINIMUM PLANTING SIZES: 2.5" Shade Tree 2" Ornamental Tree 8' Coniferous Tree IRRIGATION: e: Properties developed after May 17, 2010, with detached townhouse, two-family, townhouse or multiple-family dwelling units within the RST-2, RM or RH district and all commercial, industrial or institutional uses shall provide an exterior inground irrigation system within the property where necessary to ensure that all turf grass, ground cover of cultivated vegetation, garden, hedges, trees and shrubbery maintenance can be accomplished. L100 LA N D S C A P E O V E R V I E W P L A N * SEE SHEET L200 FOR DETAILS, NOTES AND SCHEDULES * ZONING: OFFICE PARK (OP) ZO N I N G : OF F I C E P A R K ( O P ) ZO N I N G : IN D U S T R I A L I - 1 ZO N I N G : I N D U S T R I A L I - 1 RU R A L A G R I C U L T U R A L O V E R L A Y D I S T R I C T ZO N I N G : I N D U S T R I A L I - 1 RU R A L A G R I C U L T U R A L O V E R L A Y D I S T R I C T ZO N I N G : IN D U S T R I A L I - 1 EUREKA TOWNSHIP: AGRICULTURALNEW MARKET TOWNSHIP: AGRICULTURAL PROPOSED BUILDING 1 PROPOSED BUILDING 2 PROPOSED BUILDING 3 PROPOSED BUILDING 4 PROPOSED BUILDING 5 PROPOSED BUILDING 6 PROPOSED BUILDING 7 PROPOSED BUILDING 8 LANDSCAPE PLAN 'A' NORTH-WEST SEE SHEET L101 LANDSCAPE PLAN 'B' NORTH-EAST SEE SHEET L102 LANDSCAPE PLAN 'C' SOUTH-WEST SEE SHEET L103 LANDSCAPE PLAN 'D' SOUTH-EAST SEE SHEET L104 TREE DIVERSITY MATRIX: Proposed Turf Sod, See Notes LANDSCAPE MATERIAL LEGEND: Proposed Landscape Edging, See Notes Proposed Native Seed, See Scehdule Proposed Rock Mulch Type 'A', See Notes Proposed Rock Mulch Type 'B', See Notes Existing Tree to Remain Proposed Wood Mulch, See Notes SCALE IN FEET 0 100 200 1 inch = 100 feet PR O P E R T Y L I N E PR O P E R T Y L I N E MA T C H L I N E - S H E E T L 1 0 1 MA T C H L I N E - S H E E T L 1 0 2 MATCH LINE - SHEET L101 MATCH LINE - SHEET L103 MA T C H L I N E - S H E E T L 1 0 3 MA T C H L I N E - S H E E T L 1 0 4 MATCH LINE - SHEET L102 MATCH LINE - SHEET L104 PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E TREE PRESERVATION PLAN: 1. See Civil Engineer's plans for site plan layout and dimensions. 2. Contractor to coordinate any work in the city right-of-way with City of Lakeville Public Works Department. 3. See Architect's plans for additional requirements regarding the site plan layout. 4. Place a minimum of 4" topsoil or slope dressing on all areas disturbed by construction, including right-of-way boulevards, unless specified otherwise. 5. See Civil Engineer's Plans for utility locations. 6. Irrigation plan to be design-build by landscape contractor. CITY OF LAKEVILLE LANDSCAPE TREE PRESERVATION REQUIREMENTS: GENERAL NOTES: DE S I G N G R O U P La n d s c a p e A r c h i t e c t u r e | P l a n n i n g L300 TR E E P R E S E R V A T I O N P L A N ZONING: OFFICE PARK (OP) ZO N I N G : OF F I C E P A R K ( O P ) ZO N I N G : IN D U S T R I A L I - 1 ZO N I N G : I N D U S T R I A L I - 1 RU R A L A G R I C U L T U R A L O V E R L A Y D I S T R I C T ZO N I N G : I N D U S T R I A L I - 1 RU R A L A G R I C U L T U R A L O V E R L A Y D I S T R I C T ZO N I N G : IN D U S T R I A L I - 1 EUREKA TOWNSHIP: AGRICULTURALNEW MARKET TOWNSHIP: AGRICULTURAL PROPOSED BUILDING 1 PROPOSED BUILDING 2 PROPOSED BUILDING 3 PROPOSED BUILDING 4 PROPOSED BUILDING 5 PROPOSED BUILDING 6 PROPOSED BUILDING 7 PROPOSED BUILDING 8 LANDSCAPE MATERIALS LEGEND: Existing Tree to Remain Existing Tree to Remove Tree Protection Fence TOTAL EXISTING SIGNIFICANT INCHES: 26,566 TOTAL SIGNIFICANT INCHES REMOVED: 19,301 SIGNIFICANT INCHES PRESERVED: 7,265 TOTAL MITIGATION INCHES REQUIRED: 497 Inches* COLUMNAR TREES PROPOSED: 56 (140") EVERGREEN TREES PROPOSED: 75 (225") ORNAMENTAL TREES PROPOSED: 32 (64") OVERSTORY TREES PROPOSED: 239 (597.5") TOTAL TREES PROPOSED: 402 (1,026.5 Inches) MITIGATION REQUIREMENTS SUMMARY: Zoning: Commercial, Industrial, and Special Districts Development in mixed use. commercial, industrial, and special districts may remove up to seventy percent (70%) of the total diameter inches of significant trees without replacement; any removal or disturbance of trees beyond this threshold shall require replacement tree planting or mitigation. Tree Replacement Requirements: a.Common Trees: Twelve and one-half percent (12.5%) of the diameter inches removed above the removal limits shall be replaced. b.Conifer Trees: (1) Twenty five percent (25%) of the diameter inches removed above the removal limit must be replaced. (2) Coniferous species shall be replaced with new trees, either coniferous or deciduous, at a rate of twenty five percent (25%) the diameter of inches removed. c.Hardwood Deciduous Trees: Fifty percent (50%) of the diameter inches removed above the removal limit shall be replaced with new deciduous or coniferous tree diameter inches. d.Heritage Trees: One hundred percent (100%) of diameter inches removed must be replaced. Heritage inches to be preserved on property may apply as credit towards this replacement. A credit in diameter inches will be applied at a ratio of two inches of replacement for one inch preserved (2:1) up to 50% of the required replacement diameter inches. Heritage Tree Replacement: 579 diameter inches identified on survey 415 diameter inches removed 415 diameter inches require replacement 164 diameter inches saved - Heritage tree preservation credit: 2-inch credit for each 1 inch - 164 inches preserved multiplied by 2 equals 328 inches, which is greater than 50% of the required replacement of 411 inches - 415 inches multiplied by 50% equals 207.5 diameter inch credit 207.5 diameter inches of heritage trees must be replaced. * Replacement tree species shall be limited to those identified on the City of Lakeville Building Permit Guidelines, except as otherwise approved by the City Forester, and the following: --Where ten (10) or more replacement trees are required, not more than twenty percent (20%) shall be of the same genus. --Ornamental tree species of a lesser size may comprise up to fifteen percent (15%) of the required replacement diameter inches provided that the required total replacement diameter inches is met. TREES TO REMAIN TREES TO REMOVE TREE PROTECTION FENCE, TYP. TREES TO REMOVE TREES TO REMOVE TREE TO REMOVE TREES TO REMOVE TREES TO REMOVE TREES TO REMAIN TREE PROTECTION FENCE, TYP. TREE TO REMAIN TREE PROTECTION FENCE, TYP.TREES TO REMAIN TREE PROTECTION FENCE, TYP. TREES TO REMAIN TREE PROTECTION FENCE, TYP. TREES TO REMOVE TREES TO REMAIN TREE PROTECTION FENCE, TYP. TREE PROTECTION FENCE, TYP. TREE PROTECTION FENCE, TYP. TREE PROTECTION FENCE, TYP. All trees scheduled to remain within the work limits shall have a forester limb them up, remove suckers & crossing branches, and ensure clearances for vehicles and trucks. Clear and grub any underbrush. TREES TO REMAIN IN THE WORK LIMITS NOTE: TREES TO REMOVE SCALE IN FEET 0 100 200 1 inch = 100 feet * REFER TO SHEET L305 FOR MITIGATION CALCULATIONS * Dakota County Surveyor’s Office Western Service Center ‚ 14955 Galaxie Avenue ‚ Apple Valley, MN 55124 952.891-7087 ‚ Fax 952.891-7127 ‚ www.co.dakota.mn.us January 29, 2026 City of Lakeville 20195 Holyoke Ave. Lakeville, MN 55044 Re: PRIME 35 LAKEVILLE The Dakota County Plat Commission met on January 28, 2026, to consider the preliminary plat of the above referenced plat. The plat is adjacent to CSAH 70 (215th St. W.) and is therefore subject to the Dakota County Contiguous Plat Ordinance. The site includes 8 commercial/industrial lots. The right-of-way guidelines along CSAH 70 as a 4-lane divided roadway are 75 feet of half right of way. The right-of-way needs have been met. Restricted access should be shown along all of CSAH 70. A quit claim deed to Dakota County for restricted access is required with the recording of the mylars. Access to the CSAH 70 is from Javellin Avenue via 217th Street West, and 215th Street West. As noted, the intersection at CSAH 70/215th Street West will be changed to a restricted access location in the future. Future access to the exception parcel (Anhalt property) will be from 215th Street West and/or potentially from 217th Street West. Also noted, the right turn lane for CSAH 70 at Javellin Avenue will need to be reviewed during the permitting process after approval of the final plat and offsets for sightlines may be required during the evaluation process. The Plat Commission has approved the preliminary plat provided that the described conditions are met. The Ordinance requires submittal of a final plat for review by the Plat Commission before a recommendation is made to the County Board of Commissioners. Traffic volumes on CSAH 70 are 13,300 ADT and are anticipated to be 16,800 ADT by the year 2040. No work shall commence in the County right of way until a permit is obtained from the County Transportation Department and no permit will be issued until the plat has been filed with the County Recorder’s Office. The Plat Commission does not review or approve the actual engineering design of proposed accesses or other improvements to be made in the right of way. Nothing herein is intended to restrict or limit Dakota County’s rights with regards to Dakota County rights of way or property. The Plat Commission highly recommends early contact with the Transportation Department to discuss the permitting process which reviews the design and may require construction of highway improvements, including, but not limited to, turn lanes, drainage features, limitations on intersecting street widths, medians, etc. Please contact TJ Bentley regarding permitting questions at (952) 891-7115 or Todd Tollefson regarding Plat Commission or Plat Ordinance questions at (952) 891-7070. Sincerely, Todd B. Tollefson Secretary, Plat Commission c: