HomeMy WebLinkAboutItem 05c - Al Hadi AssociationCity of Lakeville
Community Development
Memorandum
To : Planning Commission
From: Kris Jenson, Planning Manager
Date: June 15, 2026
Subject: Packet Material for the June 25, 2026 Planning Commission
Meeting
Agenda Item: Al Hadi Association Conditional Use Permit for:
1. Religious institution in the RS-3, Single Family Residential District
2. Exceed 125% of the minimum parking spaces required by the
Zoning Ordinance.
Application Action Deadline: July 31, 2026
INTRODUCTION
Applications for a conditional use permit have been submitted by
representatives of Al Hadi Association for the construction of a nearly 3,700
square foot facility as well as a parking lot which will include more than 125%
of the minimum number of parking spaces required by the Zoning
Ordinance. The property is located at 17732 Junelle Path, south of 175th Street,
behind the Cub Foods in Argonne Village.
The Al Hadi Association plans have been distributed to Engineering and
Environmental Resources staff for review.
EXHIBITS
A. Aerial Location Map
B. Zoning Map
C. Existing Condition Survey
D. Site and Dimension Plan
E. Grading & Drainage Plan
F. Utility Plan
G. Tree Preservation Plan & Inventory (3 pages)
H. Landscape Plan
I. Building Elevations (4 pages)
J. Floor Plans
K. Trash Enclosure Detail
L. Color Elevations
PLANNING ANALYSIS
Conditional Use Permit. The conditional use permit is a quasi-judicial
decision – the City’s role is to determine the facts associated with the
request and weigh those facts against
the legal standards contained in the
City Code and State Statute. In general,
if the facts indicate the applicant
meets the relevant legal standards of
the code and will not compromise the
general welfare, the applicant is likely
entitled to approval. The City is,
however, able to add conditions to
approval to ensure that any impacts
on and around the subject property
are adequately addressed.
Existing Conditions. The site has a 1,230 square foot single family home
which was constructed in 1922. The site also includes a 490 square foot
detached garage with a 230 square foot leanto, a 530 square foot barn, and a
48 square foot shed. The home and garage will be removed as part of the
construction on site. The barn and shed, both of which are located further
east on the site, atop the hill on the east half of the property, are proposed to
remain at this time. A security must be submitted to guarantee the
demolition of the existing homestead and garage and the sealing and
abandonment of the well.
Adjacent Land Uses.
North: Single family home (RS-2 District)
South: Twinhomes (PUD District)
East: Undeveloped property (RS-2 District)
West: Argonne Hills senior housing (O-R District), Junelle Path, Cub
Foods/Argonne Village commercial center (PUD District)
Zoning. The subject property is zoned RS-2, Single Family Residential District
which allows religious institution uses by conditional use permit.
Setbacks. The proposed structure meets the RS-2 District setback
requirements, as follows:
Front and rear yards – 30 feet
Side Yards – 30 feet
Religious institutions are required to have double the side yard setback
requirements of the zoning district in which the property is located, so the
side yard setbacks is 30 feet, rather than the 15 feet required for a
residential dwelling.
Streets. The subject site abuts Junelle Path, which is a 38-foot-wide local
street within a 66-foot-wide right-of-way. Junelle Path is posted for no
parking.
Trails and Sidewalks. There is not a sidewalk along Junelle Path.
Grading, Drainage and Utility Plans. The grading, drainage and utility
plans were submitted to the Engineering Division for their review. The civil
plans are still under review and must be finalized prior to consideration by
the City Council. Please refer to the June 17, 2026 Engineering Division
report from Jon Nelson, Assistant City Engineer and McKenzie Cafferty,
Environmental Resources Manager, for more detailed review comments.
Tree Preservation. The City Forester reviewed the submitted tree
preservation plan, which identified trees on the west portion of the site,
where construction will take place. Based on the trees included in the
inventory, there are 813 significant tree diameter inches on site, and 509
inches proposed to be removed, which requires the replacement of 23
inches of require tree diameter to be planted on site. The plans indicate
that maple, white pine, and crabapple trees will be planted to meet the 23
inches of required tree planting. The City Forester will confirm the tree
removal calculations prior to the approval of the SIPA by the City Council.
CONDITIONAL USE PERMIT
Section 11-51-7.D allows religious institutions in the RS-2, Single Family
Residential District subject to approval of a conditional use permit. Section
11-19-13.J allows the number of parking spaces to exceed 125% of the
minimum number required by conditional use permit subject to the
following criteria:
A. The use and the site in question shall be served by a street of sufficient
capacity to accommodate the type and volume of traffic which would
be generated and adequate right of way shall be provided.
The site is served by Junelle Path, which is classified as a local street.
Junelle Path as constructed is 38 feet, measured from the back of curb
to back of curb and is wider than a typical local residential street,
which generally measures 32 feet from the back of curb to the back of
curb.
B. The site design for access and parking shall minimize internal as well as
external traffic conflicts and shall be in compliance with chapter 19 of
this title.
Access to the site will remain unchanged with the change in use for the
site.
C. If applicable, a pedestrian circulation system shall be clearly defined and
appropriate provisions made to protect such areas from encroachment
by parked or moving vehicles.
A sidewalk is provided along the front and side of the building,
adjacent to the parking lot.
D. Adequate off street parking and off street loading shall be provided in
compliance with chapters 19 and 20 of this title.
The site proposes 59 parking spaces. Parking for religious institutions is
calculated based on the design capacity of the main assembly, which
in this case has a capacity for 118 persons and requiring a minimum of
39 parking spaces. A conditional use permit is being processed because
the site is proposing in excess of 125% of the Zoning Ordinance
requirements, which is supported by staff.
The applicant has provided information about the activities to be
expected at the site. The mosque will operate daily from 1 pm to 9 pm,
during which 8-10 members are expected to stop by to perform prayers.
The main assembly time is on Friday between 12 noon and 2pm, when
it is expected that up to 70 members will attend services. During those
times, there is expected to be up to 10 staff members on site as well.
Some of the other activities that will take place on site are a monthly
youth program and a group study one night per week. The primary
factor in providing additional parking is that on-street parking is not
permitted on Junelle Path, so should additional spaces be needed
above the 39 required spaces, the site can accommodate those
vehicles.
E. Loading areas and drive-up facilities shall be positioned so as to
minimize internal site access problems and maneuvering conflicts, to
avoid visual or noise impacts on any "adjacent" residential use or district,
and provided in compliance with chapter 20 of this title.
Not applicable.
F. Whenever a nonresidential use "is adjacent to" a residential use or
district, a buffer area with screening and landscaping shall be provided
in compliance with chapter 21 of this title.
Landscaping is proposed in the southwest corner of the property and
north and east of the parking lot. In the southwest corner, there are five
trees proposed to be saved, which provide some buffering of the site
from Junelle Path and the homes to the south. Five Little Giant
arborvitae shrubs are proposed just inside the property line, to provide
additional screening. The applicant looked at adding trees or other
plantings amongst the existing trees in this area for buffering, but in
consultation with the City Forester it was recommended to not add
plantings in that area, out of concern for potential damage to the roots
of those trees and the ability for new plantings to survive give the heavy
tree canopy that exists. The Little Giant Arborvitae shrubs will also be
planted between the parking and the stormwater pond, for additional
screening of the parking lot.
Brandon Arborvitae shrubs are proposed along the parking spaces
south of the building and along 125 feet of the north side of the west
parking area. These plantings are intended to screen the parking lot
and minimize vehicle headlights from shining on adjacent parcels.
Finally, four white pine trees are proposed to be planted among the
existing trees just north of the parking area, which slopes up steeply
towards the east.
G. General site screening and landscaping shall be provided in compliance
with chapter 21 of this title.
The landscape plan includes proposed plantings around the south and
west sides of the building and within the parking lot. The City Forester
has reviewed and approved the landscape plan. Prior to any landscape
inspections on site, an as-planted landscape plan must be submitted
to Forestry staff.
H. All exterior lighting shall be so directed so as not to cast glare toward or
onto the public right of way or neighboring residential uses or districts,
and shall be in compliance with section 11-16-17 of this title.
The photometric plan indicates that all lighting on site will be on the
building; parking lot lighting is not proposed. All building mounted
lights must be facing downward onto the structure per Section 11-16-17.
The light levels indicated on the photometric plan are in compliance
with section 11-16-17 of the Zoning Ordinance.
I. Potential exterior noise generated by the use shall be identified and
mitigation measures as may be necessary shall be imposed to ensure
compliance with section 11-16-25 of this title.
There is not anticipated to be any exterior noise generated by the use
beyond the general day to day activity. The applicant has indicated
that there will not be a call to prayer broadcast outside of the mosque.
J. The site drainage system shall be subject to the review and approval of
the city engineer.
The stormwater system is still under review by Engineering staff. The
civil plans must be approved by the Engineering Division as well as a
Site Improvement Performance Agreement and Stormwater
Maintenance Agreement executed by the Developer and approved by
the City Council prior to any construction beginning on site.
K. The architectural appearance and functional design of the building and
site shall not be so dissimilar to the existing or potential buildings and
area so as to cause a blighting influence. All sides of the principal and
accessory structures are to have essentially the same or coordinated,
harmonious exterior finish materials and treatment.
The proposed building has a footprint of just under 3,700 square feet
and will primarily be clad in brick with windows on all four sides of the
building. These two materials total 70.4% of the exterior, in compliance
with Zoning Ordinance requirements. The remainder of the structure is
proposed to be stucco and architectural panels with a natural material
finish; these materials are grade B and grade C and account for 29.6%
of the exterior materials. The primary colors of the building are two
shades of cream, while the domed area at the front entrance includes
two darker shades of brown and dark green metal dome over the
entrance.
The proposed structure has an overall height to the peak of 31 feet,
10.75, which is less than the 35 foot maximum height allowed in the RS-
2 district. Building height for peaked roofs is typically measured from
grade level to the midpoint of the roof, which in this case is about 26
feet. The building also proposes a minaret which has an overall height
of 38 feet, 7 inches. The minaret is built as a part of the building and is
therefore exempt from the height requirements of the RS-2 District per
Section 11-17-74 D, which states that building height limits do not apply
to church spires and crosses or other symbols as an element of the
principal building.
L. Provisions shall be made for daily litter control, an interior location for
recycling, and trash handling and storage or an outdoor, enclosed
receptacle area shall be provided in compliance with section 11-18-11 of
this title.
A trash enclosure is proposed to be located just east of the main
entrance, in the corner of the parking lot. The exterior materials must
be compatible with the proposed structure and include a
maintenance-free gate.
M. All signs and informational or visual communication devices shall be in
compliance with chapter 23 of this title.
A sign has not been indicated on the plans at this time and the
applicant has indicated that a sign is not planned at this time. If a sign
is proposed for the site, it must be in compliance with Section 11-23-19
and a permit be issued prior to installation.
N. The use and site shall be in compliance with any federal, state or county
law or regulation that is applicable and any related permits shall be
obtained and documented to the city.
Not applicable
O. Any applicable business licenses mandated by this code are approved
and obtained.
Not applicable
P. The hours of operation may be restricted when there is judged to be an
incompatibility with a residential use or district.
The hours of mosque operation are not expected to be incompatible
with the area.
Q. The use complies with all applicable performance standards of the
zoning district in which it is located and where applicable.
The use complies with the performance standards of the RS-2 district.
RECOMMENDATION
Community Development staff have reviewed the plans for Al Hadi
Association and determined they meet the requirements of the Zoning
Ordinance and recommends approval of a conditional use permit, subject
to the following stipulations:
1. The stipulations and recommendations listed in the Engineering
Division memorandum dated June 17, 2026.
2. Civil plans must be approved by the Engineering Division prior to
construction beginning on the site.
3. A Site Improvement Performance Agreement (SIPA) and Stormwater
Maintenance Agreement (SMA) must be executed, approved by the
City Council, and recorded with Dakota County prior to construction
beginning on the site.
4. The building and site shall be developed consistent with the plans
approved by the City Council.
5. A landscape security shall be submitted with the SIPA.
6. An as-planted landscape plan must be submitted prior to a landscape
inspection of the site.
Findings of fact are attached for consideration.
Dakota County, Microsoft, Vantor
City of Lakeville
Location Map
Al Hadi Association
CUP
JUN
E
L
L
E
P
A
T
H
JUNELLE CT
Subject
Property
±
Cub
Foods
EXHIBIT A
City of Lakeville
Location Map
Al Hadi Association
CUP
JUN
E
L
L
E
P
A
T
H
JUNELLE CT
Subject
Property
±EXHIBIT A
SHEET NO. C2
No. TAG #SPECIES DIAMETER
(Inches)HEIGHT (Feet) CONDITION TYPE OF TREE
REMOVALS
TREE
YES/NOT
TOTAL
DIAMETER ON
SITE (Inches)
TOTAL
DIAMETER ON
REMOVED
(Inches)
1 103 CRABAPPLE 12 8 COMMON TREE NO
2 138 ASH 7 8 COMMON TREE YES
3 139 ASH 13 8 COMMON TREE YES
4 140 ASH 7 8 COMMON TREE YES
5 142 ASH 10 8 COMMON TREE NO
6 145 MAPLE 7 8 COMMON TREE NO
7 147 ASH 18 8 COMMON TREE NO
8 152 ASH 6 8 COMMON TREE YES
9 154 ASH 6 8 COMMON TREE YES
10 156 ASH 16 8 COMMON TREE YES
11 160 ASH 13 8 COMMON TREE YES
12 161 ASH 12 8 COMMON TREE YES
13 162 ASH 11 8 COMMON TREE YES
14 163 ASH 7 8 COMMON TREE YES
15 164 ASH 15 8 COMMON TREE YES
16 165 ASH 14 8 COMMON TREE YES
17 166 ASH 14 8 COMMON TREE YES
18 167 BUCKTHORN N/A 8 COMMON TREE YES
19 168 ASH 18 8 COMMON TREE YES
20 169 BUCKTHORN N/A 8 COMMON TREE NO
21 171 ASH 24 8 COMMON TREE NO
22 173 ASH 6 8 COMMON TREE NO
23 174 ASH 6 8 COMMON TREE NO
24 175 ASH 7 8 COMMON TREE NO
25 104 BOXELDER 8 8 COMMON TREE YES
26 111 CRABAPPLE 16 8 COMMON TREE YES
27 115 CATALPA 8 8 COMMON TREE YES
28 116 CRABAPPLE 8 8 COMMON TREE YES
29 117 COTTONWOOD 72 8 COMMON TREE YES
30 118 BUCKTHORN N/A 8 COMMON TREE YES
31 119 BUCKTHORN N/A 8 COMMON TREE YES
32 120 BUCKTHORN N/A 8 COMMON TREE YES
33 121 BUCKTHORN N/A 8 COMMON TREE YES
34 122 ASH N/A 8 COMMON TREE YES
35 123 BUCKTHORN N/A 8 COMMON TREE YES
36 124 ASH N/A 8 COMMON TREE YES
37 125 ASH N/A 8 COMMON TREE YES
38 126 BUCKTHORN N/A 8 COMMON TREE YES
39 129 BUCKTHORN N/A 8 COMMON TREE YES
40 131 ASH N/A 8 COMMON TREE YES
41 132 ASH N/A 8 COMMON TREE YES
42 135 BUCKTHORN N/A 8 COMMON TREE YES
43 136 ASH N/A 8 COMMON TREE YES
44 143 BUCKTHORN N/A 8 COMMON TREE YES
45 144 BUCKTHORN N/A 8 COMMON TREE YES 361 271
46 100 SPRUCE 12 8 CONIFEROUS TREE NO
47 112 SPRUCE 18 8 CONIFEROUS TREE NO
48 170 PINE 14 40 8 CONIFEROUS TREE NO
49 105 SPRUCE 8 8 CONIFEROUS TREE YES
50 106 SPRUCE 8 8 CONIFEROUS TREE YES
51 107 SPRUCE 8 8 CONIFEROUS TREE YES
52 108 SPRUCE 8 8 CONIFEROUS TREE YES
53 109 SPRUCE 8 8 CONIFEROUS TREE YES
54 110 SPRUCE 8 8 CONIFEROUS TREE YES 92 48
55 101 OAK 40 8 HARDWOOD DECIDUOUS TREE NO
56 102 OAK 20 8 HARDWOOD DECIDUOUS TREE NO
57 141 OAK 22 8 HARDWOOD DECIDUOUS TREE YES
58 148 OAK 14 8 HARDWOOD DECIDUOUS TREE YES
59 149 OAK 20 8 HARDWOOD DECIDUOUS TREE YES
60 151 OAK 12 8 HARDWOOD DECIDUOUS TREE YES
61 153 OAK 20 8 HARDWOOD DECIDUOUS TREE YES
62 155 OAK 18 8 HARDWOOD DECIDUOUS TREE YES
63 176 OAK 24 8 HARDWOOD DECIDUOUS TREE YES
64 157 OAK 18 8 HARDWOOD DECIDUOUS TREE YES
65 158 OAK 14 8 HARDWOOD DECIDUOUS TREE YES
66 159 OAK 24 8 HARDWOOD DECIDUOUS TREE YES
67 114 HONEY LOCUST 20 8 HARDWOOD DECIDUOUS TREE NO
68 128 OAK 10 8 HARDWOOD DECIDUOUS TREE YES
69 130 OAK 18 8 HARDWOOD DECIDUOUS TREE YES 294 190
70 113 OAK 36 8 HERITAGE TREE NO
71 172 OAK 30 8 HERITAGE TREE NO 66 0
72 127 ASH 18 D EAD YES
73 133 ASH 18 DEAD YES
74 134 ASH 24 DEAD YES
75 137 BUCKTHORN 7 DEAD YES
76 146 ASH 18 DEAD YES
77 150 ASH 8 DEAD YES 93 93
T OTAL TREES (COUNT)
TREES BEING
REMOVED
(COUNT)
TOTAL
DIAMETER ON
SITE (IN.)
TOTAL
DIAMETER OF
REMOVED
TREES (IN.)
45 36 361 271
9 6 92 48
15 12 294 190
2 0 66 0
71 54 813 509
325 TOTAL SIGNIFICANT X TREES X 40%SAVED 37.4%
REMOVED 62.6%509
BY DIAMETER (INCHES)
TREE CLASSIFICATION
TOTALS
COMMON TREES
CONIFEROUS TREE
HARDWOOD DECIDUOUS TREES
HERITAGE TREES
Table 1:
Tree classification Total significant tree
diameter inches on site
Total significant tree
diameter inches removed
Common 361 271
Coniferous 92 48
Hardwood deciduous 294 190
Heritage trees 66 0
TOTAL 813 509
Table 2:
Removal Threshold Allowable removal of
significant diameter inches
40% removal threshold 325
70% removal threshold 569
Determine the rate of
required tree replacement
With a 40% removal
threshold
With a 70% removal
threshold
Subtract total significant
common diameter inches
removed from threshold 54 298
Common inches that require
replacement 0 0
then subtract total significant
conifer diameter inches from
the above result
6 250
Conifer inches that require
replacement 0 0
hardwood deciduous diameter
inches from the above result
-184 250
Hardwood deciduous inches
that require replacement 183.8 0.0
Table 4:
Determine the rate of
required tree replacement
With a 40% removal
threshold
With a 70% removal
threshold
Tree replacement required for
common trees
(1/8 diameter inches)0.0 0.0
Tree replacement required for
conifer trees
(1/4 diameter inches)0.0 0.0
Tree replacement required for
hardwood deciduous
(1/2 diameter inches)91.9 0.0
Significant tree replacement
required for heritage trees
(100% diameter inches)0.0 0.0
replacement required
(diameter inches). Not
including credits.91.9 0.0
Table 5:
Total inches of heritage trees
preserved on site.66.0
Total preserved significant
inches located within an
(Not including inches from
heritage trees, as they are
already counted above)747.0
Determine required tree
replacement including
credits.
With a 40% removal
threshold
With a 70% removal
threshold
Credits from the larger of the
two above totals (diameter
inches)46.0 0.0
Remaining required tree
replacement in diameter
inches 46.0 0.0
two above totals (diameter
inches)23.0 0.0
Final required tree
replacement
(diameter inches)
23.0 0.0
Directions: Fill all cells highlighted in yellow with the numbers from your tree preservation plan.
Table 3: If at any point the calculation in this table goes below zero, all remaining significant
Table 6: The larger of the two totals shown in table 5 is computed into credit first. The smaller
PLANT SCHEDULE
1 EVERGREEN SHRUB QTY COMMON NAME BOTANICAL NAME CONT
BA 40 BRANDON ARBORVITAE THUJA OCCIDENTALIS "BRANDON" MIN. 6 FT. TALL
2 EVERGREEN SHRUB QTY COMMON NAME BOTANICAL NAME CONT
LGAA 4 LITTLE GIANT AMERICAN ARBORVITAE THUJA OCCIDENTALIS "LITTLE GIANT" 6 FT. TALL & WIDE
3 DECIDUOUS TREE QTY COMMON NAME BOTANICAL NAME CONT
MP 5 MAPLE ACER MIN. CALIPER 2.5 INCHES
4 CONIFEROUS TREE QTY COMMON NAME BOTANICAL NAME CONT
BHS 4 WHITE PINE PINUS STROBUS MIN. 6 FT. TALL
5 DECIDUOUS TREE QTY COMMON NAME BOTANICAL NAME CONT
CB 2 CRABAPPLE MALUS MIN. CALIPER 2 INCHES
6 DECIDUOUS SHRUB QTY COMMON NAME BOTANICAL NAME CONT
HP 2 HYDRANGEA "PANICULATA"PANICLE HYDRANGEA 2 GAL.
7
HV 6 HYDRANGEA "BLUE" HYDRAGEA MACROPHYLLA "NIKKO BLUE" 2 GAL.
8 PERENNIAL GRASS QTY COMMON NAME BOTANICAL NAME CONT
WPG 10 WHITE PAMPAS GRASS CORTADERIA SELLOANA 1 GAL.
9 SHRUB QTY COMMON NAME BOTANICAL NAME CONT
C 40 CORNUS GREY DOGWOOD 5 GAL. 6-9 FT. HEIGHT& WIDHT
10 PERENNIAL GRASS QTY COMMON NAME BOTANICAL NAME CONT
HV 4 HOSTA "VENTRICOSA" ASPARAGACEAEA 1 GAL.
TOTAL 117
38
'
-
6
7
/
8
"
SCALE: 1/4" = 1'-0"
FRONT/SOUTH ELEVATION1
5
1
/
4
"
10
'
-
0
"
9'
-
1
1
/
8
"
8'
-
0
"
6"
2'
-
0
3
/
4
"
8'
-
1
1
/
8
"
6'
-
8
"
5
1
/
4
"
10
'
-
0
"
9'
-
1
1
/
8
"
8'
-
0
"
6"
2'
-
0
3
/
4
"
8'
-
1
1
/
8
"
6'
-
8
"
31
'
-
1
0
3
/
4
"
R12'-0"
FRONT COLUMN
PER DETAIL
MINARET PER DETAIL
4" TRIM
PER SPEC.
GRADING AND/OR HANDICAP
ACCESSIBLE SIDEWALK BY
OTHERS AND/OR PER CIVIL
ENGINEER DESIGN
DOMED METAL ROOF
STONEWORK BEHIND
STUCCO
1. ICE AND WATER BARRIER @ BOTTOM 6' OF ALL ROOF LINES,
EXTEND BARRIER MIN. 3' ON EACH SIDE OF VALLEY, COVER
ENTIRE FACE OF ROOF SADDLES. VERIFY ADDITIONAL
LOCATIONS OF ICE AND WATER BARRIER AS NEEDED IN
FIELD.
2. PROVIDE ROOF AND SOFFIT VENTS PER CODE
REGULATIONS.
3. ALL FURNACE FLUES, PLUMBING VENTS, FIREPLACE VENTS,
AND OTHER PENETRATIONS THROUGH ROOF OR WALLS TO
EXTEND THROUGH REAR OF HOME WHENEVER POSSIBLE.
4. ALL PENETRATIONS THROUGH EXTERIOR WALLS OR
ROOFING MUST BE SEALED AND FLASHED PER
MANUFACTURE. SPECIFICATIONS AND CODE REGULATIONS.
5. SUPPLY AT LEAST 6" OF SPACE BETWEEN BOTTOMS OF
WINDOWS AND ROOFS.
6. ALL BEAMS HOLDING UP PORCH ROOFS ARE TO BE
DROPPED UNLESS OTHERWISE NOTED.
7. SUPPLY DRIPCAPS ON ALL WINDOWS AND DOORS.
8. ALL EXTERIOR TRIM TO BE FLASHED PER CODE
9. SUPPLY SEPARATION BETWEEN WOOD, COMPOSITE WOOD,
AND ANY OTHER WOOD MATERIAL PER SPECIFICATIONS.
-MATERIAL: STANDING
SEAM METAL.
-MATERIAL: FABRICATED
FIBERGLASS SHINGLES.
-MATERIAL:
ARCHITECTURAL
PANELS W/SIMULATED
NATURAL MATERIAL FINISH,
VERIFY W/SPEC.
-MATERIAL: STUCCO,
VERIFY W/ SPEC.
-MATERIAL:
BRICK, VERIFY
W/ SPEC.
3/4" = 1'-0"
COLUMN OVER STONE BASE DETAIL2
BASE
TOP
3" PRE-CAST CONCRETE
CAP EXTENDED 2" PAST
EDGES OF STONE BELOW
MIN. (1)#4 REBAR DOWEL
EXTENDED THROUGH BASE
18" CMU BLOCK, FILLED (OR)
POURED IN PLACE BASE
TO HEIGHT NOTED ON
EXTERIOR ELEVATIONS
EXTEND DOWEL 4" INTO FOUNDATION
OR SLAB BELOW (OR) ANCHOR
PER MASON DETAIL
BRICK FINISH AT SIDES
OF COLUMN PER EXTERIORS
CENTER POST, VERIFY
WITH PLAN.
19" COLUMN FINISH
MATERIAL PER SPEC.
METAL CONNECTOR
@ PRE-CAST BASE
SECTION
CENTER POST, VERIFY
WITH PLAN, MAY BE AT
CORNER.
19" COLUMN FINISH
MATERIAL PER SPEC.
@ ALL SIDES.
2X FRAMING AT MIDDLE
TO SUPPORT FINISHES.
CENTER POST, VERIFY
WITH PLAN, MAY BE AT
CORNER.
METAL CONNECTOR
@ TOP
2X FRAMING BEYOND AT MIDDLE
TO SUPPORT FINISHES.
CENTER POST, VERIFY
WITH PLAN.
18" CURVED GLULAM BEAM
TAPERED COLUMN FINISH
MATERIAL BEYOND. PROVIDE
2X FRAMING TO SUPPORT
EXTERIOR FINISHES ALONG
ARCHED OPENINGS
4'
-
6
3
/
4
"
BASE
3" PRE-CAST CONCRETE
CAP EXTENDED 2" PAST
EDGES OF STONE BELOW
MIN. (1)#4 REBAR DOWEL
EXTENDED THROUGH BASE
3'-0" CMU BLOCK, FILLED (OR)
POURED IN PLACE BASE
TO HEIGHT NOTED ON
EXTERIOR ELEVATIONS
EXTEND DOWEL 4" INTO FOUNDATION
OR SLAB BELOW (OR) ANCHOR
PER MASON DETAIL
BRICK FINISH AT SIDES
OF COLUMN PER EXTERIORS
2X6 TIMBERSTRAND
STUDS
MINARET FINISH
MATERIAL PER SPEC.
METAL CONNECTOR
@ PRE-CAST BASE
MINARET FINISH
MATERIAL PER SPEC.
2X FRAMING AT MIDDLE
TO SUPPORT FINISHES.
TAPER TO TOP OF MINARET.
2X6 TIMBERSTRAND
STUDS FRAMED AS SHOWN.
WIDER MINARET BASE
BELOW
2X FRAMING AT MINARET
TOP TO SUPPORT FINISHES.
TAPER TO TOP OF MINARET.
MINARET FINISH
MATERIAL PER SPEC.
2X FRAMING AT CENTER OF
MINARET TOP TO PROVIDE
SUPPORT FOR METAL
DECORATIVE CAP ABOVE.
2X6 TIMBERSTRAND
STUDS
METAL CONNECTOR
@ TOP
DECORATIVE METAL CRECENT MOON
MINARET CAP BY OTHERS.
METAL MINARET CAP
FASTENERS BY OTHERS
3/4" = 1'-0"
MINARET DETAIL3
10. HOLD STONE OFF GRADE MINIMUM OF 3" OR PER TRADE
SPECIFICATIONS.
11. REFER TO MANUFACTURE SPECIFICATIONS FOR STONE.
12. GRADE CONDITIONS MAY VARY ON SITE.
A.) 8" FASCIA PER SPEC.
B.) VENTILATED SOFFIT
AT OVERHANGS
C.) CLADDING PER PLAN
A.) 4" STUCCO TRIM
AROUND STUCCO
POINTED ARCH PER SPEC.
B.) WINDOW PER PLAN
VA
R
I
E
S
A.) 3" PRECAST CAP
PER SPEC.
B.) BRICK VENEER PER
PLAN
D.) GRADE
C.) MEASUREMENT FROM
TOP OF CAP TO GRADE
DRAWING TITLE:
5−27−26LOCATION:
PAGE PAGE DESCRIPTION:
L D
LITTFINDESIGN.COM
MLITTFIN @HOTMAIL.COM
320−224−7844
WINSTED, MN
CURRENT
DATE:
REVISION:REV. DATE:ALL PLANS & DESIGNS SHOWN
ARE THE PROPERTY OF LITTFIN
DESIGN. USE OF THESE PLANS
ON ANY OTHER PROJECT/LOT
OTHER THAN NOTED ON THIS
TITLEBLOCK WITHOUT THE
WRITTEN CONSENT OF LITTFIN
DESIGN IS PROHIBITED.
THIS PLAN PROVIDES BUILDING DETAILS FOR A PROJECT TO BE BUILT IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AS WELL AS ANY LOCAL CODES. CONTRACTOR, OWNER, AND/OR TRADES ARE RESPONSIBLE FOR ANY FINES, PENALTIES FOR CODE, ORDINANCE, REGULATION OR BUILDING PROCESS VIOLATIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR OMISSIONS OR ERRORS
MADE DURING DESIGN, BIDDING, OR CONSTRUCTION PHASES. ANY AND ALL SITE REVIEW IS TO BE PERFORMED BY OTHERS SUCH AS THE CONTRACTOR, OWNER, SURVEYOR, OR OTHER TRADES RESPONSIBLE FOR SITE CONDITIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR CONTRACTOR/TRADE ERRORS, UNKNOWN CODE ADJUSTMENTS AT THE TIME OF PLAN CREATION OR CONSTRUCTION.
STRUCTURAL NOTES ADDED 3-6-26
PAGES E1-E3 & BRICK VENEER DETAILS ADDED (D1)5-27-26 A1 FRONT
ELEVATION
SCALED PRINT @ 24X36
SCALE: 1/4" = 1'-0"
LEFT/WEST ELEVATION1
5
1
/
4
"
10
'
-
0
"
16
'
-
0
"
11
'
-
0
"
6"
3'
-
4
"
9'
-
1
1
/
8
"
8'
-
0
"
2'
-
0
3
/
4
"
8'
-
1
1
/
8
"
6'
-
8
"
R12'-0"
R5'-0"
FRONT COLUMN
PER DETAIL
MINARET PER DETAIL
6'
-
6
"
2'
-
6
"
5'
-
6
"
4'
-
6
3
/
4
"
4" TRIM
PER SPEC.
4'-0"
2'
-
6
"
4'-0"
2'
-
6
"
4'-0"
2'
-
6
"
4'-0"3'-0"
GRADING AND/OR HANDICAP
ACCESSIBLE SIDEWALK BY
OTHERS AND/OR PER CIVIL
ENGINEER DESIGN
GRADING AND/OR HANDICAP
ACCESSIBLE SIDEWALK BY
OTHERS AND/OR PER CIVIL
ENGINEER DESIGN
DOMED METAL ROOF
DOMED METAL ROOF
12
'
-
6
1
/
2
"
13
'
-
1
1
1
/
4
"
1. ICE AND WATER BARRIER @ BOTTOM 6' OF ALL ROOF LINES,
EXTEND BARRIER MIN. 3' ON EACH SIDE OF VALLEY, COVER
ENTIRE FACE OF ROOF SADDLES. VERIFY ADDITIONAL
LOCATIONS OF ICE AND WATER BARRIER AS NEEDED IN
FIELD.
2. PROVIDE ROOF AND SOFFIT VENTS PER CODE
REGULATIONS.
3. ALL FURNACE FLUES, PLUMBING VENTS, FIREPLACE VENTS,
AND OTHER PENETRATIONS THROUGH ROOF OR WALLS TO
EXTEND THROUGH REAR OF HOME WHENEVER POSSIBLE.
4. ALL PENETRATIONS THROUGH EXTERIOR WALLS OR
ROOFING MUST BE SEALED AND FLASHED PER
MANUFACTURE. SPECIFICATIONS AND CODE REGULATIONS.
5. SUPPLY AT LEAST 6" OF SPACE BETWEEN BOTTOMS OF
WINDOWS AND ROOFS.
6. ALL BEAMS HOLDING UP PORCH ROOFS ARE TO BE
DROPPED UNLESS OTHERWISE NOTED.
7. SUPPLY DRIPCAPS ON ALL WINDOWS AND DOORS.
8. ALL EXTERIOR TRIM TO BE FLASHED PER CODE
9. SUPPLY SEPARATION BETWEEN WOOD, COMPOSITE WOOD,
AND ANY OTHER WOOD MATERIAL PER SPECIFICATIONS.3/4" = 1'-0"
COLUMN OVER STONE BASE DETAIL2
BASE
TOP
3" PRE-CAST CONCRETE
CAP EXTENDED 2" PAST
EDGES OF STONE BELOW
MIN. (1)#4 REBAR DOWEL
EXTENDED THROUGH BASE
18" CMU BLOCK, FILLED (OR)
POURED IN PLACE BASE
TO HEIGHT NOTED ON
EXTERIOR ELEVATIONS
EXTEND DOWEL 4" INTO FOUNDATION
OR SLAB BELOW (OR) ANCHOR
PER MASON DETAIL
BRICK FINISH AT SIDES
OF COLUMN PER EXTERIORS
CENTER POST, VERIFY
WITH PLAN.
19" COLUMN FINISH
MATERIAL PER SPEC.
METAL CONNECTOR
@ PRE-CAST BASE
SECTION
CENTER POST, VERIFY
WITH PLAN, MAY BE AT
CORNER.
19" COLUMN FINISH
MATERIAL PER SPEC.
@ ALL SIDES.
2X FRAMING AT MIDDLE
TO SUPPORT FINISHES.
CENTER POST, VERIFY
WITH PLAN, MAY BE AT
CORNER.
METAL CONNECTOR
@ TOP
2X FRAMING BEYOND AT MIDDLE
TO SUPPORT FINISHES.
CENTER POST, VERIFY
WITH PLAN.
18" CURVED GLULAM BEAM
TAPERED COLUMN FINISH
MATERIAL BEYOND. PROVIDE
2X FRAMING TO SUPPORT
EXTERIOR FINISHES ALONG
ARCHED OPENINGS
4'
-
6
3
/
4
"
BASE
3" PRE-CAST CONCRETE
CAP EXTENDED 2" PAST
EDGES OF STONE BELOW
MIN. (1)#4 REBAR DOWEL
EXTENDED THROUGH BASE
3'-0" CMU BLOCK, FILLED (OR)
POURED IN PLACE BASE
TO HEIGHT NOTED ON
EXTERIOR ELEVATIONS
EXTEND DOWEL 4" INTO FOUNDATION
OR SLAB BELOW (OR) ANCHOR
PER MASON DETAIL
BRICK FINISH AT SIDES
OF COLUMN PER EXTERIORS
2X6 TIMBERSTRAND
STUDS
MINARET FINISH
MATERIAL PER SPEC.
METAL CONNECTOR
@ PRE-CAST BASE
MINARET FINISH
MATERIAL PER SPEC.
2X FRAMING AT MIDDLE
TO SUPPORT FINISHES.
TAPER TO TOP OF MINARET.
2X6 TIMBERSTRAND
STUDS FRAMED AS SHOWN.
WIDER MINARET BASE
BELOW
2X FRAMING AT MINARET
TOP TO SUPPORT FINISHES.
TAPER TO TOP OF MINARET.
MINARET FINISH
MATERIAL PER SPEC.
2X FRAMING AT CENTER OF
MINARET TOP TO PROVIDE
SUPPORT FOR METAL
DECORATIVE CAP ABOVE.
2X6 TIMBERSTRAND
STUDS
METAL CONNECTOR
@ TOP
DECORATIVE METAL CRECENT MOON
MINARET CAP BY OTHERS.
METAL MINARET CAP
FASTENERS BY OTHERS
3/4" = 1'-0"
MINARET DETAIL3
10. HOLD STONE OFF GRADE MINIMUM OF 3" OR PER TRADE
SPECIFICATIONS.
11. REFER TO MANUFACTURE SPECIFICATIONS FOR STONE.
12. GRADE CONDITIONS MAY VARY ON SITE.
A.) 8" FASCIA PER SPEC.
B.) VENTILATED SOFFIT
AT OVERHANGS
C.) CLADDING PER PLAN
A.) 4" STUCCO TRIM
AROUND STUCCO
POINTED ARCH PER SPEC.
B.) WINDOW PER PLAN
VA
R
I
E
S
A.) 3" PRECAST CAP
PER SPEC.
B.) BRICK VENEER PER
PLAN
D.) GRADE
C.) MEASUREMENT FROM
TOP OF CAP TO GRADE
-MATERIAL: STANDING
SEAM METAL.
-MATERIAL: FABRICATED
FIBERGLASS SHINGLES.
-MATERIAL:
ARCHITECTURAL
PANELS W/SIMULATED
NATURAL MATERIAL FINISH,
VERIFY W/SPEC.
-MATERIAL: STUCCO,
VERIFY W/ SPEC.
-MATERIAL:
BRICK, VERIFY
W/ SPEC.
DRAWING TITLE:
5−27−26LOCATION:
PAGE PAGE DESCRIPTION:
L D
LITTFINDESIGN.COM
MLITTFIN @HOTMAIL.COM
320−224−7844
WINSTED, MN
CURRENT
DATE:
REVISION:REV. DATE:ALL PLANS & DESIGNS SHOWN
ARE THE PROPERTY OF LITTFIN
DESIGN. USE OF THESE PLANS
ON ANY OTHER PROJECT/LOT
OTHER THAN NOTED ON THIS
TITLEBLOCK WITHOUT THE
WRITTEN CONSENT OF LITTFIN
DESIGN IS PROHIBITED.
THIS PLAN PROVIDES BUILDING DETAILS FOR A PROJECT TO BE BUILT IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AS WELL AS ANY LOCAL CODES. CONTRACTOR, OWNER, AND/OR TRADES ARE RESPONSIBLE FOR ANY FINES, PENALTIES FOR CODE, ORDINANCE, REGULATION OR BUILDING PROCESS VIOLATIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR OMISSIONS OR ERRORS
MADE DURING DESIGN, BIDDING, OR CONSTRUCTION PHASES. ANY AND ALL SITE REVIEW IS TO BE PERFORMED BY OTHERS SUCH AS THE CONTRACTOR, OWNER, SURVEYOR, OR OTHER TRADES RESPONSIBLE FOR SITE CONDITIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR CONTRACTOR/TRADE ERRORS, UNKNOWN CODE ADJUSTMENTS AT THE TIME OF PLAN CREATION OR CONSTRUCTION.
STRUCTURAL NOTES ADDED 3-6-26
PAGES E1-E3 & BRICK VENEER DETAILS ADDED (D1)5-27-26 A2 LEFT
ELEVATION
SCALED PRINT @ 24X36
SCALE: 1/4" = 1'-0"
REAR/NORTH ELEVATION1
5
1
/
4
"
10
'
-
0
"
16
'
-
0
"
11
'
-
0
"
6"5
1
/
4
"
10
'
-
0
"
16
'
-
0
"
11
'
-
0
"
6"
R5'-8"
MINARET PER DETAIL
DOMED METAL ROOF
17
'
-
1
1
1
/
4
"
12
'
-
6
1
/
2
"
1. ICE AND WATER BARRIER @ BOTTOM 6' OF ALL ROOF LINES,
EXTEND BARRIER MIN. 3' ON EACH SIDE OF VALLEY, COVER
ENTIRE FACE OF ROOF SADDLES. VERIFY ADDITIONAL
LOCATIONS OF ICE AND WATER BARRIER AS NEEDED IN
FIELD.
2. PROVIDE ROOF AND SOFFIT VENTS PER CODE
REGULATIONS.
3. ALL FURNACE FLUES, PLUMBING VENTS, FIREPLACE VENTS,
AND OTHER PENETRATIONS THROUGH ROOF OR WALLS TO
EXTEND THROUGH REAR OF HOME WHENEVER POSSIBLE.
4. ALL PENETRATIONS THROUGH EXTERIOR WALLS OR
ROOFING MUST BE SEALED AND FLASHED PER
MANUFACTURE. SPECIFICATIONS AND CODE REGULATIONS.
5. SUPPLY AT LEAST 6" OF SPACE BETWEEN BOTTOMS OF
WINDOWS AND ROOFS.
6. ALL BEAMS HOLDING UP PORCH ROOFS ARE TO BE
DROPPED UNLESS OTHERWISE NOTED.
7. SUPPLY DRIPCAPS ON ALL WINDOWS AND DOORS.
8. ALL EXTERIOR TRIM TO BE FLASHED PER CODE
9. SUPPLY SEPARATION BETWEEN WOOD, COMPOSITE WOOD,
AND ANY OTHER WOOD MATERIAL PER SPECIFICATIONS.
-MATERIAL: STANDING
SEAM METAL.
-MATERIAL: FABRICATED
FIBERGLASS SHINGLES.
-MATERIAL:
ARCHITECTURAL
PANELS W/SIMULATED
NATURAL MATERIAL FINISH,
VERIFY W/SPEC.
-MATERIAL: STUCCO,
VERIFY W/ SPEC.
-MATERIAL:
BRICK, VERIFY
W/ SPEC.
3/4" = 1'-0"
COLUMN OVER STONE BASE DETAIL2
BASE
TOP
3" PRE-CAST CONCRETE
CAP EXTENDED 2" PAST
EDGES OF STONE BELOW
MIN. (1)#4 REBAR DOWEL
EXTENDED THROUGH BASE
18" CMU BLOCK, FILLED (OR)
POURED IN PLACE BASE
TO HEIGHT NOTED ON
EXTERIOR ELEVATIONS
EXTEND DOWEL 4" INTO FOUNDATION
OR SLAB BELOW (OR) ANCHOR
PER MASON DETAIL
BRICK FINISH AT SIDES
OF COLUMN PER EXTERIORS
CENTER POST, VERIFY
WITH PLAN.
19" COLUMN FINISH
MATERIAL PER SPEC.
METAL CONNECTOR
@ PRE-CAST BASE
SECTION
CENTER POST, VERIFY
WITH PLAN, MAY BE AT
CORNER.
19" COLUMN FINISH
MATERIAL PER SPEC.
@ ALL SIDES.
2X FRAMING AT MIDDLE
TO SUPPORT FINISHES.
CENTER POST, VERIFY
WITH PLAN, MAY BE AT
CORNER.
METAL CONNECTOR
@ TOP
2X FRAMING BEYOND AT MIDDLE
TO SUPPORT FINISHES.
CENTER POST, VERIFY
WITH PLAN.
18" CURVED GLULAM BEAM
TAPERED COLUMN FINISH
MATERIAL BEYOND. PROVIDE
2X FRAMING TO SUPPORT
EXTERIOR FINISHES ALONG
ARCHED OPENINGS
4'
-
6
3
/
4
"
BASE
3" PRE-CAST CONCRETE
CAP EXTENDED 2" PAST
EDGES OF STONE BELOW
MIN. (1)#4 REBAR DOWEL
EXTENDED THROUGH BASE
3'-0" CMU BLOCK, FILLED (OR)
POURED IN PLACE BASE
TO HEIGHT NOTED ON
EXTERIOR ELEVATIONS
EXTEND DOWEL 4" INTO FOUNDATION
OR SLAB BELOW (OR) ANCHOR
PER MASON DETAIL
BRICK FINISH AT SIDES
OF COLUMN PER EXTERIORS
2X6 TIMBERSTRAND
STUDS
MINARET FINISH
MATERIAL PER SPEC.
METAL CONNECTOR
@ PRE-CAST BASE
MINARET FINISH
MATERIAL PER SPEC.
2X FRAMING AT MIDDLE
TO SUPPORT FINISHES.
TAPER TO TOP OF MINARET.
2X6 TIMBERSTRAND
STUDS FRAMED AS SHOWN.
WIDER MINARET BASE
BELOW
2X FRAMING AT MINARET
TOP TO SUPPORT FINISHES.
TAPER TO TOP OF MINARET.
MINARET FINISH
MATERIAL PER SPEC.
2X FRAMING AT CENTER OF
MINARET TOP TO PROVIDE
SUPPORT FOR METAL
DECORATIVE CAP ABOVE.
2X6 TIMBERSTRAND
STUDS
METAL CONNECTOR
@ TOP
DECORATIVE METAL CRECENT MOON
MINARET CAP BY OTHERS.
METAL MINARET CAP
FASTENERS BY OTHERS
3/4" = 1'-0"
MINARET DETAIL3
10. HOLD STONE OFF GRADE MINIMUM OF 3" OR PER TRADE
SPECIFICATIONS.
11. REFER TO MANUFACTURE SPECIFICATIONS FOR STONE.
12. GRADE CONDITIONS MAY VARY ON SITE.
A.) 8" FASCIA PER SPEC.
B.) VENTILATED SOFFIT
AT OVERHANGS
C.) CLADDING PER PLAN
A.) 4" STUCCO TRIM
AROUND STUCCO
POINTED ARCH PER SPEC.
B.) WINDOW PER PLAN
VA
R
I
E
S
A.) 3" PRECAST CAP
PER SPEC.
B.) BRICK VENEER PER
PLAN
D.) GRADE
C.) MEASUREMENT FROM
TOP OF CAP TO GRADE
DRAWING TITLE:
5−27−26LOCATION:
PAGE PAGE DESCRIPTION:
L D
LITTFINDESIGN.COM
MLITTFIN @HOTMAIL.COM
320−224−7844
WINSTED, MN
CURRENT
DATE:
REVISION:REV. DATE:ALL PLANS & DESIGNS SHOWN
ARE THE PROPERTY OF LITTFIN
DESIGN. USE OF THESE PLANS
ON ANY OTHER PROJECT/LOT
OTHER THAN NOTED ON THIS
TITLEBLOCK WITHOUT THE
WRITTEN CONSENT OF LITTFIN
DESIGN IS PROHIBITED.
THIS PLAN PROVIDES BUILDING DETAILS FOR A PROJECT TO BE BUILT IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AS WELL AS ANY LOCAL CODES. CONTRACTOR, OWNER, AND/OR TRADES ARE RESPONSIBLE FOR ANY FINES, PENALTIES FOR CODE, ORDINANCE, REGULATION OR BUILDING PROCESS VIOLATIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR OMISSIONS OR ERRORS
MADE DURING DESIGN, BIDDING, OR CONSTRUCTION PHASES. ANY AND ALL SITE REVIEW IS TO BE PERFORMED BY OTHERS SUCH AS THE CONTRACTOR, OWNER, SURVEYOR, OR OTHER TRADES RESPONSIBLE FOR SITE CONDITIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR CONTRACTOR/TRADE ERRORS, UNKNOWN CODE ADJUSTMENTS AT THE TIME OF PLAN CREATION OR CONSTRUCTION.
STRUCTURAL NOTES ADDED 3-6-26
PAGES E1-E3 & BRICK VENEER DETAILS ADDED (D1)5-27-26 A3 REAR
ELEVATION
SCALED PRINT @ 24X36
SCALE: 1/4" = 1'-0"
RIGHT/EAST ELEVATION1
5
1
/
4
"
10
'
-
0
"
16
'
-
0
"
11
'
-
0
"
6"
R5'-0"
R12'-0"
FRONT COLUMN
PER DETAIL
9'
-
1
1
/
8
"
8'
-
0
"
2'
-
0
3
/
4
"
8'
-
1
1
/
8
"
6'
-
8
"
3'
-
4
"
4'
-
6
3
/
4
"
15
'
-
1
1
1
/
4
"
4" TRIM
PER SPEC.
EXTEND RAILING
12" BEYOND TOP
AND BOTTOM OF
STAIRS PER CODE
EXTEND RAILING
12" BEYOND TOP
AND BOTTOM OF
STAIRS PER CODE
FOUNDATION/ MECHANICAL
ROOM EXTERIOR STAIRCASE
ACCESS
FLOOR DRAIN INSTALLED AT
BOTTOM OF STAIRWELL
GRADING AND/OR HANDICAP
ACCESSIBLE SIDEWALK BY
OTHERS AND/OR PER CIVIL
ENGINEER DESIGN
13
'
-
0
"
DOMED METAL ROOF
DOMED METAL ROOF
13
'
-
1
1
1
/
4
"
12
'
-
6
1
/
2
"
1. ICE AND WATER BARRIER @ BOTTOM 6' OF ALL ROOF LINES,
EXTEND BARRIER MIN. 3' ON EACH SIDE OF VALLEY, COVER
ENTIRE FACE OF ROOF SADDLES. VERIFY ADDITIONAL
LOCATIONS OF ICE AND WATER BARRIER AS NEEDED IN
FIELD.
2. PROVIDE ROOF AND SOFFIT VENTS PER CODE
REGULATIONS.
3. ALL FURNACE FLUES, PLUMBING VENTS, FIREPLACE VENTS,
AND OTHER PENETRATIONS THROUGH ROOF OR WALLS TO
EXTEND THROUGH REAR OF HOME WHENEVER POSSIBLE.
4. ALL PENETRATIONS THROUGH EXTERIOR WALLS OR
ROOFING MUST BE SEALED AND FLASHED PER
MANUFACTURE. SPECIFICATIONS AND CODE REGULATIONS.
5. SUPPLY AT LEAST 6" OF SPACE BETWEEN BOTTOMS OF
WINDOWS AND ROOFS.
6. ALL BEAMS HOLDING UP PORCH ROOFS ARE TO BE
DROPPED UNLESS OTHERWISE NOTED.
7. SUPPLY DRIPCAPS ON ALL WINDOWS AND DOORS.
8. ALL EXTERIOR TRIM TO BE FLASHED PER CODE
9. SUPPLY SEPARATION BETWEEN WOOD, COMPOSITE WOOD,
AND ANY OTHER WOOD MATERIAL PER SPECIFICATIONS.
-MATERIAL: STANDING
SEAM METAL.
-MATERIAL: FABRICATED
FIBERGLASS SHINGLES.
-MATERIAL:
ARCHITECTURAL
PANELS W/SIMULATED
NATURAL MATERIAL FINISH,
VERIFY W/SPEC.
-MATERIAL: STUCCO,
VERIFY W/ SPEC.
-MATERIAL:
BRICK, VERIFY
W/ SPEC.
3/4" = 1'-0"
COLUMN OVER STONE BASE DETAIL2
BASE
TOP
3" PRE-CAST CONCRETE
CAP EXTENDED 2" PAST
EDGES OF STONE BELOW
MIN. (1)#4 REBAR DOWEL
EXTENDED THROUGH BASE
18" CMU BLOCK, FILLED (OR)
POURED IN PLACE BASE
TO HEIGHT NOTED ON
EXTERIOR ELEVATIONS
EXTEND DOWEL 4" INTO FOUNDATION
OR SLAB BELOW (OR) ANCHOR
PER MASON DETAIL
BRICK FINISH AT SIDES
OF COLUMN PER EXTERIORS
CENTER POST, VERIFY
WITH PLAN.
19" COLUMN FINISH
MATERIAL PER SPEC.
METAL CONNECTOR
@ PRE-CAST BASE
SECTION
CENTER POST, VERIFY
WITH PLAN, MAY BE AT
CORNER.
19" COLUMN FINISH
MATERIAL PER SPEC.
@ ALL SIDES.
2X FRAMING AT MIDDLE
TO SUPPORT FINISHES.
CENTER POST, VERIFY
WITH PLAN, MAY BE AT
CORNER.
METAL CONNECTOR
@ TOP
2X FRAMING BEYOND AT MIDDLE
TO SUPPORT FINISHES.
CENTER POST, VERIFY
WITH PLAN.
18" CURVED GLULAM BEAM
TAPERED COLUMN FINISH
MATERIAL BEYOND. PROVIDE
2X FRAMING TO SUPPORT
EXTERIOR FINISHES ALONG
ARCHED OPENINGS
4'
-
6
3
/
4
"
BASE
3" PRE-CAST CONCRETE
CAP EXTENDED 2" PAST
EDGES OF STONE BELOW
MIN. (1)#4 REBAR DOWEL
EXTENDED THROUGH BASE
3'-0" CMU BLOCK, FILLED (OR)
POURED IN PLACE BASE
TO HEIGHT NOTED ON
EXTERIOR ELEVATIONS
EXTEND DOWEL 4" INTO FOUNDATION
OR SLAB BELOW (OR) ANCHOR
PER MASON DETAIL
BRICK FINISH AT SIDES
OF COLUMN PER EXTERIORS
2X6 TIMBERSTRAND
STUDS
MINARET FINISH
MATERIAL PER SPEC.
METAL CONNECTOR
@ PRE-CAST BASE
MINARET FINISH
MATERIAL PER SPEC.
2X FRAMING AT MIDDLE
TO SUPPORT FINISHES.
TAPER TO TOP OF MINARET.
2X6 TIMBERSTRAND
STUDS FRAMED AS SHOWN.
WIDER MINARET BASE
BELOW
2X FRAMING AT MINARET
TOP TO SUPPORT FINISHES.
TAPER TO TOP OF MINARET.
MINARET FINISH
MATERIAL PER SPEC.
2X FRAMING AT CENTER OF
MINARET TOP TO PROVIDE
SUPPORT FOR METAL
DECORATIVE CAP ABOVE.
2X6 TIMBERSTRAND
STUDS
METAL CONNECTOR
@ TOP
DECORATIVE METAL CRECENT MOON
MINARET CAP BY OTHERS.
METAL MINARET CAP
FASTENERS BY OTHERS
3/4" = 1'-0"
MINARET DETAIL3
10. HOLD STONE OFF GRADE MINIMUM OF 3" OR PER TRADE
SPECIFICATIONS.
11. REFER TO MANUFACTURE SPECIFICATIONS FOR STONE.
12. GRADE CONDITIONS MAY VARY ON SITE.
A.) 8" FASCIA PER SPEC.
B.) VENTILATED SOFFIT
AT OVERHANGS
C.) CLADDING PER PLAN
A.) 4" STUCCO TRIM
AROUND STUCCO
POINTED ARCH PER SPEC.
B.) WINDOW PER PLAN
VA
R
I
E
S
A.) 3" PRECAST CAP
PER SPEC.
B.) BRICK VENEER PER
PLAN
D.) GRADE
C.) MEASUREMENT FROM
TOP OF CAP TO GRADE
DRAWING TITLE:
5−27−26LOCATION:
PAGE PAGE DESCRIPTION:
L D
LITTFINDESIGN.COM
MLITTFIN @HOTMAIL.COM
320−224−7844
WINSTED, MN
CURRENT
DATE:
REVISION:REV. DATE:ALL PLANS & DESIGNS SHOWN
ARE THE PROPERTY OF LITTFIN
DESIGN. USE OF THESE PLANS
ON ANY OTHER PROJECT/LOT
OTHER THAN NOTED ON THIS
TITLEBLOCK WITHOUT THE
WRITTEN CONSENT OF LITTFIN
DESIGN IS PROHIBITED.
THIS PLAN PROVIDES BUILDING DETAILS FOR A PROJECT TO BE BUILT IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AS WELL AS ANY LOCAL CODES. CONTRACTOR, OWNER, AND/OR TRADES ARE RESPONSIBLE FOR ANY FINES, PENALTIES FOR CODE, ORDINANCE, REGULATION OR BUILDING PROCESS VIOLATIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR OMISSIONS OR ERRORS
MADE DURING DESIGN, BIDDING, OR CONSTRUCTION PHASES. ANY AND ALL SITE REVIEW IS TO BE PERFORMED BY OTHERS SUCH AS THE CONTRACTOR, OWNER, SURVEYOR, OR OTHER TRADES RESPONSIBLE FOR SITE CONDITIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR CONTRACTOR/TRADE ERRORS, UNKNOWN CODE ADJUSTMENTS AT THE TIME OF PLAN CREATION OR CONSTRUCTION.
STRUCTURAL NOTES ADDED 3-6-26
PAGES E1-E3 & BRICK VENEER DETAILS ADDED (D1)5-27-26 A4 RIGHT
ELEVATION
SCALED PRINT @ 24X36
Ø5'-0"
SCALE: 1/4" = 1'-0" 3571 FINISHED SQUARE FEET
FIRST FLOOR PLAN1
R5'-8"
R12'-0"
UP (18) EQ. R.
& 12" TREADS
DN (16) EQ. R.
& 12" TREADS
Ø5'-0"
8"
6"
6"
8"
6"
6"
6"
6"
6"
6"
6"
6"
6"
6"6"
6"
13'-7 1/4"7'-7 1/4"7'-7 1/4"7'-7 1/4"4'-8 3/4"
5 1/2"
6'-10 1/4"7'-1 3/4"5'-0"14'-4 1/2"2'-0"3'-6"
8'
-
2
1
/
4
"
8'
-
2
1
/
4
"
8'
-
2
1
/
4
"
8'
-
2
1
/
4
"
16
'
-
4
1
/
2
"
11
'
-
3
"
16
'
-
4
1
/
2
"
4'-6"9'-1 1/4"7'-7 1/4"7'-7 1/4"7'-7 1/4"4'-8 3/4"
5 1/2"
3'-6"2'-6"6'-2 1/2"6'-2 1/2"5'-11 1/4"13'-7 3/4"
4'
-
4
1
/
4
"
7'
-
7
3
/
4
"
7'
-
7
3
/
4
"
4'
-
4
1
/
4
"
41'-1 1/2"14'-0"19'-4 1/2"5'-6"
10
'
-
0
"
24
'
-
0
"
10
'
-
0
"
1'
-
7
1
/
4
"
8'
-
4
3
/
4
"
5
1
/
2
"
5
1
/
2
"
80'-0"4'-0"12'-0"5'-0"
101'-0"
45
'
-
0
"
1'
-
0
"
45
'
-
0
"
12
'
-
4
1
/
4
"
24
'
-
7
3
/
4
"
7'
-
0
"
41'-1 1/2"10 1/2"12'-5"19'-7"
12'-0"4'-0"32'-0"6'-0"42'-0"
5'-0"
5'-0"
101'-0"
10
'
-
0
3
/
4
"
2'
-
3
1
/
2
"
5'
-
1
0
1
/
2
"
2'
-
0
"
9'
-
1
0
3
/
4
"
8'
-
1
0
1
/
4
"
3'
-
6
"
5'
-
5
1
/
2
"
8'
-
1
0
1
/
4
"
5'
-
3
1
/
2
"
8'
-
4
3
/
4
"
7'-0"7'-0"7'-5 1/2"6'-6 1/2"3'-10 1/2"1'-6"
6'-10"4'-0"2'-0"7'-6"
5
1
/
2
"
4'
-
3
1
/
2
"
4'
-
0
"
12'-10 3/4"6'-4 3/4"7'-5 1/2"6'-6 1/2"5'-6 1/2"4'-0 1/2"
2'
-
0
3
/
4
"
3'
-
8
"
4'
-
4
"
4'
-
6
"
8'-0"3'-5 1/2"
TEMP.
TEMP.
4'
-
0
"
4'
-
0
"
1'
-
0
"
5'
-
0
1
/
2
"
5'
-
6
"
6'
-
1
0
1
/
4
"
6'
-
1
0
1
/
4
"
5
1
/
2
"
36" CODE RAILING
36" CODE RAILING 36" CODE RAILING
5 1/2"
1
D1
1
D3/D4
1
D2
1'-6 1/2"1'-6 1/2"
1'-4"
1'-4"
1'-6 1/2"1'-6 1/2"
D
D
A
B
CEC
CO
N
T
R
O
L
L
E
R
2
1
/
2
"
2 1/2"2
1
/
2
"
5 1/2"2 1/2"
TE
M
P
.
TE
M
P
.
8'
-
5
1
/
4
"
5'
-
5
1
/
2
"
5
1
/
2
"
5
1
/
2
"
8 9 10 11
12 13 14 15 16
7 6 5 4 4 3 2 1
11'-1 1/4"
9'-6"4'-0"3'-6"
INSTALL BEAM
POCKETS
2" WIDER &
2" DEEPER
THAN BEAM
1
D7
2
D7
3
D7
4
D7
5
D7
6
D7
7
D7
8
D7
6"
1'
-
0
"
1'
-
0
"
6
3
/
4
"
3'
-
0
"
4'
-
1
0
1
/
2
"
3'-11"
1'-7"
7'-1
0
"
1'-7"
7'
-
1
0
"
16
'
-
5
1
/
2
"
1'-7"
7'-1
0"
1'-7"
3'-11"
5.5"x18" CURVED
GLULAM BEAM
TO SUPPORT DOME
CURBLESS
CURBLESS
8"
HATCHED AREA INDICATES
SPECIAL FRAMING PER
NOTE #5 UNDER FLOOR
PLAN NOTES ON THIS PAGE.
HATCHED AREA INDICATES
SPECIAL FRAMING PER NOTE
#5 UNDER FLOOR PLAN
NOTES ON THIS PAGE.
HATCHED AREA INDICATES
SPECIAL FRAMING PER
NOTE #6 UNDER FLOOR
PLAN NOTES ON THIS PAGE.
HATCHED AREA INDICATES
SPECIAL FRAMING PER
NOTE #6 UNDER FLOOR
PLAN NOTES ON THIS PAGE.
HATCHED AREA INDICATES
SPECIAL FRAMING PER
NOTE #6 UNDER FLOOR
PLAN NOTES ON THIS PAGE.
HATCHED AREA INDICATES
SPECIAL FRAMING PER
NOTE #6 UNDER FLOOR
PLAN NOTES ON THIS PAGE.
BEAM BEARS ON TOP OF FOUND.
WALL, INSTALL (4)#4 VERTICAL
REBAR DOWELS FROM TOP TO
BOTTOM OF CORNER W/ #3 REBAR
HORIZONTAL CAGE BARS EVERY
6" O.C. TO REINFORCE CORNER
POURED FOUNDATION WALL
AT SIDES OF ELEVATOR
POURED FOUNDATION WALL
AT SIDES OF ELEVATOR
EXTEND RAILING
12" BEYOND TOP
AND BOTTOM OF
STAIRS PER CODE
FIRE EXIT
DIRECTIONAL SIGN ABV.
FIRE EXIT
DIRECTIONAL SIGN ABV.
FIRE EXIT
DIRECTIONAL SIGN ABV.
FI
R
E
E
X
I
T
DI
R
E
C
T
I
O
N
A
L
S
I
G
N
A
B
V
.
FIRE EXIT
DIRECTIONAL SIGN ABV.
SOAP DISPENSER
SOAP DISPENSER
PANIC/ EXIT
PUSH BARS
@ DOOR
PANIC/ EXIT
PUSH BARS
@ DOOR
PANIC/ EXIT
PUSH BARS
@ DOOR
PANIC/ EXIT
PUSH BARS
@ DOOR
PANIC/ EXIT
PUSH BARS
@ DOOR
U305 WALL
U305 WALL
U305 WALL
LOCKING
LEVER HANDLE
@ DOOR
FIRST FLOOR STAIRWELL
WALL EXTENDED TO
BOTTOM SIDE OF SECOND
FLOOR WALL
1-HOUR SHAFT
U305 WALL
U305 WALL
1. ALL HEADERS TO BE SUPPORTED BY A MINIMUM OF (1)
TRIMMER.
2. ALL HEADERS TO HAVE AT LEAST (1) KING STUD (UNLESS
NOTED).
3. BLOCKING @ ROOF & FLOOR PLAN PER TRUSS
MANUFACTURER.
4. POINT LOADS TO BE CARRIED THROUGH FLOOR AREAS
AND DOWN TO FOUNDATION FOR SUPPORT. USE SAME
MATERIAL AS COLUMN SUPPORTING MEMBER ABOVE.
5. ALL HANGERS & CONNECTORS PER TRUSS
MANUFACTURER, SUPPLIERS & CONTRACTOR.
6. ALL EXTERIOR SHEATHING TO BE 7/16" OSB OR
PLYWOOD SHEATHING & NAILED PER CODE (MAY BE
REFERRED TO AS 1/2" NOMINAL THICKNESS).
7. ROOF DECKING TO BE 1
2" NOMINAL (OR 15
32") OSB DECKING
W/ CLIPS, NAILED TO ROOF FRAMING W/ MIN. 8d COMMON
NAILS, 6" O.C. @ EDGES/12"O.C. @ FIELD.
8. FLOOR DECKING TO BE 3
4" PLYWOOD DECKING, NAILED
OR SCREWED TO FLOOR SYSTEM PER CODE W/
ADHESIVE PER SPEC. (OR) MIN. 6d COMMON NAILS 6" O.C.
@ EDGES/12" O.C. @ FIELD (CODE MINIMUM).
1. ALL NON-BEARING FRAMING IS TO BE 16" O.C.
UNLESS OTHERWISE NOTED.
2. ALL WALLS TO HAVE A DOUBLE TOP PLATE
UNLESS OTHERWISE NOTED.
3. ALL EXTERIOR WALLS ARE TO BE 2X6 WOOD
STUDS WITH 7/16" OSB SHEATHING, UNLESS
NOTED OTHERWISE.
4. ALL INTERIOR WALLS ARE TO BE 2X4 WOOD
STUDS UNLESS NOTED OTHERWISE.
5. ALL COLUMN SIZES ARE TO BE CONTINUED
THROUGH FLOOR TRUSS SPACES WHEN
SPANNING MORE THAN 1 FLOOR.
6. ALL WOOD MATERIALS ARE TO BE PROTECTED
PER CODE & MANUF. SPECIFICATIONS WHILE
BEING STORED ON SITE.
-SH3'X5' =SINGLE HUNG 3'0" BY 5'0"
-FX2'6"X2'6" = FIXED 2'6" BY 4'6"
-CASE3'X5' = CASEMENT 3'0" BY 5'0"
-2'8"X6'8" @ DOOR =2'8" WIDE BY 6'8" TALL
-2'8"X8'0" @ DOOR =2'8" WIDE BY 8'0" TALL
110V, INTERCONNECTED SMOKE
DETECTOR
110V, INTERCONNECTED SMOKE
DETECTOR / CARBON
MONOXIDE DETECTOR COMBO
EXHAUST FAN
1. FOR EASE OF UNDERSTANDING GRADE IS
CONSIDERED 0'0" ON THIS PLAN
2. ALL STAIRWAYS (INTERIOR AND EXTERIOR)
ARE TO BE ILLUMINATED AT EACH LANDING
PER CODE
3. SUPPLY CONTINUOUS HANDRAIL PER CODE
AT ALL STAIR LOCATIONS, CODE HANDRAIL IS
TO CONTINUE TO LANDINGS/ TOP & BOTTOM
OF STAIRS. EXTEND RAILING 12" BEYOND TOP
AND BOTTOM OF STAIRS PER CODE
CONTRACTOR & INSTALLER TO VERIFY IF
ADDITIONAL GRASPABLE HANDRAIL IS
INSTALLED OR IF DECORATIVE HANDRAIL
TO CONTINUE.
4.1
2" GYPSUM BOARD TO BE APPLIED TO
UNDERSIDE OF STAIRS PER CODE.
5. INDICATES INTERIOR
BEARING WALL, 16" O.C. STUDS
6. INDICATES EXTERIOR WALL
STUDS SPACED AT 12" O.C. 1.55E
TIMBERSTRAND MATERIAL OR BETTER (2-PLY
TIMBER-STRAND KING STUDS @ EACH SIDE OF
OPENINGS IN WALL).
7. INSTALL DRAFT STOPPING WITHIN FLOOR
SYSTEM PER CODE SECTION 302.12, MIN. 1
2"
GYPSUM BOARD (OR) 3
8" STRUCTURAL BOARD
ADEQUATELY SUPPORTED BY 2X4 MIN.
MATERIAL, PARALLEL WITH FLOOR FRAMING,
SEPARATING AREAS WITH MAXIMUM SPACE OF
1000 SQ.FT.-SEPARATE INTO EQUAL SPACES.
SD
SD
DOOR INFORMATION ::::
1. ALL DOORS TO BE SOLID CORE UNLESS NOTED
OTHERWISE.
2. EXTERIOR DOORS TO BE HOLLOW METAL OR
ALUMINUM DOORS AND FRAMES.
3. PROVIDE 60−MINUTE FIRE−RATED DOORS AT ALL STAIR
ENCLOSURES.
4. PROVIDE LEVER−TYPE HANDLES AT ALL DOORS.
5.
5.1. WASH SINK CLOSET
5.2. OFFICES (2)
6.
6.1. FRONT ENTRANCE DOORS
6.2. SIDE VESTIBULE DOOR
6.3. SIDE PRAYER HALL DOOR
6.4. FUTURE DOOR (VESTIBULE AREA)
6.5. BASEMENT EGRESS DOOR
SQUARE FOOTAGE CALCULATIONS
UNFINISHED SQ. FTG. 3341 SQ.FT.
FINISHED SQ. FTG.3571 SQ.FT.
FINISHED SQ. FTG. 1662 SQ.FT.
TOTAL FINISHED SQ. FTG:5233 SQ.FT.
GRAND TOTAL SQ. FTG: 8574 SQ.FT.
DRAWING TITLE:
5−27−26LOCATION:
PAGE PAGE DESCRIPTION:
L D
LITTFINDESIGN.COM
MLITTFIN @HOTMAIL.COM
320−224−7844
WINSTED, MN
CURRENT
DATE:
REVISION:REV. DATE:ALL PLANS & DESIGNS SHOWN
ARE THE PROPERTY OF LITTFIN
DESIGN. USE OF THESE PLANS
ON ANY OTHER PROJECT/LOT
OTHER THAN NOTED ON THIS
TITLEBLOCK WITHOUT THE
WRITTEN CONSENT OF LITTFIN
DESIGN IS PROHIBITED.
THIS PLAN PROVIDES BUILDING DETAILS FOR A PROJECT TO BE BUILT IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AS WELL AS ANY LOCAL CODES. CONTRACTOR, OWNER, AND/OR TRADES ARE RESPONSIBLE FOR ANY FINES, PENALTIES FOR CODE, ORDINANCE, REGULATION OR BUILDING PROCESS VIOLATIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR OMISSIONS OR ERRORS
MADE DURING DESIGN, BIDDING, OR CONSTRUCTION PHASES. ANY AND ALL SITE REVIEW IS TO BE PERFORMED BY OTHERS SUCH AS THE CONTRACTOR, OWNER, SURVEYOR, OR OTHER TRADES RESPONSIBLE FOR SITE CONDITIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR CONTRACTOR/TRADE ERRORS, UNKNOWN CODE ADJUSTMENTS AT THE TIME OF PLAN CREATION OR CONSTRUCTION.
STRUCTURAL NOTES ADDED 3-6-26
PAGES E1-E3 & BRICK VENEER DETAILS ADDED (D1)5-27-26 A7 FIRST FLOOR
PLAN
SCALED PRINT @ 24X36
SCALE: 1/4" = 1'-0" 1662 FINISHED SQUARE FEET
SECOND FLOOR PLAN1
DN (18) EQ. R.
& 12" TREADS
8"
6"
6"
8"6"
6"
6"
6"
6"
6"
6"
6"
6'-11 1/4"5'-4 1/4"6'-9 1/2"19'-10 1/2"
12
'
-
0
"
12
'
-
0
"
41'-0 1/2"12'-3 1/2"26'-8"
80'-0"4'-0"12'-0"
96'-0"
44
'
-
0
"
10
'
-
0
"
24
'
-
0
"
10
'
-
0
"
44
'
-
0
"
41'-0 1/2"12'-3 1/2"26'-8"
80'-0"4'-0"12'-0"
96'-0"
12
'
-
4
1
/
4
"
5'
-
1
0
1
/
2
"
8'
-
5
1
/
4
"
5'
-
3
1
/
2
"
12
'
-
0
3
/
4
"
10'-9 1/2"7'-6"4'-0"8'-3 1/2"5'-2"3'-3 1/2"4'-2 1/2"
2'
-
4
1
/
4
"
5'
-
5
1
/
2
"
8'
-
1
0
1
/
4
"
5'
-
3
1
/
2
"
2'
-
0
3
/
4
"
36" CODE RAILING
36
"
C
O
D
E
R
A
I
L
I
N
G
36" CODE RAILING
36" CODE RAILING
5
1
/
2
"
5
1
/
2
"
5 1/2"
5 1/2"
1
D3/D4
1
D1
1
D2
D
D
A
B
CEC
CO
N
T
R
O
L
L
E
R
2
1
/
2
"
2 1/2"2
1
/
2
"
R12'-0"
10 11
12 13 14 15 16 17 18
9 8 7 6 5 4 3 2
HATCHED AREA INDICATES
SPECIAL FRAMING PER
NOTE #6 UNDER FLOOR
PLAN NOTES ON THIS PAGE.
HATCHED AREA INDICATES
SPECIAL FRAMING PER
NOTE #6 UNDER FLOOR
PLAN NOTES ON THIS PAGE.
HATCHED AREA INDICATES
SPECIAL FRAMING PER
NOTE #6 UNDER FLOOR
PLAN NOTES ON THIS PAGE.
HATCHED AREA INDICATES
SPECIAL FRAMING PER
NOTE #6 UNDER FLOOR
PLAN NOTES ON THIS PAGE.
POURED FOUNDATION WALL
AT SIDES OF ELEVATOR
POURED FOUNDATION WALL
AT SIDES OF ELEVATOR
EXTEND RAILING
12" BEYOND TOP
AND BOTTOM OF
STAIRS PER CODE
U305 WALL
U305 WALL
U305 WALL
LOCKING
LEVER HANDLE
@ DOOR
LOCKING
LEVER HANDLE
@ DOOR
1-HOUR SHAFT
1. ALL HEADERS TO BE SUPPORTED BY A MINIMUM OF (1)
TRIMMER.
2. ALL HEADERS TO HAVE AT LEAST (1) KING STUD (UNLESS
NOTED).
3. BLOCKING @ ROOF & FLOOR PLAN PER TRUSS
MANUFACTURER.
4. POINT LOADS TO BE CARRIED THROUGH FLOOR AREAS
AND DOWN TO FOUNDATION FOR SUPPORT. USE SAME
MATERIAL AS COLUMN SUPPORTING MEMBER ABOVE.
5. ALL HANGERS & CONNECTORS PER TRUSS
MANUFACTURER, SUPPLIERS & CONTRACTOR.
6. ALL EXTERIOR SHEATHING TO BE 7/16" OSB OR
PLYWOOD SHEATHING & NAILED PER CODE (MAY BE
REFERRED TO AS 1/2" NOMINAL THICKNESS).
7. ROOF DECKING TO BE 1
2" NOMINAL (OR 15
32") OSB DECKING
W/ CLIPS, NAILED TO ROOF FRAMING W/ MIN. 8d COMMON
NAILS, 6" O.C. @ EDGES/12"O.C. @ FIELD.
8. FLOOR DECKING TO BE 3
4" PLYWOOD DECKING, NAILED
OR SCREWED TO FLOOR SYSTEM PER CODE W/
ADHESIVE PER SPEC. (OR) MIN. 6d COMMON NAILS 6" O.C.
@ EDGES/12" O.C. @ FIELD (CODE MINIMUM).
1. ALL NON-BEARING FRAMING IS TO BE 16" O.C.
UNLESS OTHERWISE NOTED.
2. ALL WALLS TO HAVE A DOUBLE TOP PLATE
UNLESS OTHERWISE NOTED.
3. ALL EXTERIOR WALLS ARE TO BE 2X6 WOOD
STUDS WITH 7/16" OSB SHEATHING, UNLESS
NOTED OTHERWISE.
4. ALL INTERIOR WALLS ARE TO BE 2X4 WOOD
STUDS UNLESS NOTED OTHERWISE.
5. ALL COLUMN SIZES ARE TO BE CONTINUED
THROUGH FLOOR TRUSS SPACES WHEN
SPANNING MORE THAN 1 FLOOR.
6. ALL WOOD MATERIALS ARE TO BE PROTECTED
PER CODE & MANUF. SPECIFICATIONS WHILE
BEING STORED ON SITE.
-SH3'X5' =SINGLE HUNG 3'0" BY 5'0"
-FX2'6"X2'6" = FIXED 2'6" BY 4'6"
-CASE3'X5' = CASEMENT 3'0" BY 5'0"
-2'8"X6'8" @ DOOR =2'8" WIDE BY 6'8" TALL
-2'8"X8'0" @ DOOR =2'8" WIDE BY 8'0" TALL
110V, INTERCONNECTED SMOKE
DETECTOR
110V, INTERCONNECTED SMOKE
DETECTOR / CARBON
MONOXIDE DETECTOR COMBO
EXHAUST FAN
1. FOR EASE OF UNDERSTANDING GRADE IS
CONSIDERED 0'0" ON THIS PLAN
2. ALL STAIRWAYS (INTERIOR AND EXTERIOR)
ARE TO BE ILLUMINATED AT EACH LANDING
PER CODE
3. SUPPLY CONTINUOUS HANDRAIL PER CODE
AT ALL STAIR LOCATIONS, CODE HANDRAIL IS
TO CONTINUE TO LANDINGS/ TOP & BOTTOM
OF STAIRS. EXTEND RAILING 12" BEYOND TOP
AND BOTTOM OF STAIRS PER CODE
CONTRACTOR & INSTALLER TO VERIFY IF
ADDITIONAL GRASPABLE HANDRAIL IS
INSTALLED OR IF DECORATIVE HANDRAIL
TO CONTINUE.
4.1
2" GYPSUM BOARD TO BE APPLIED TO
UNDERSIDE OF STAIRS PER CODE.
5. INDICATES INTERIOR
BEARING WALL, 16" O.C. STUDS
6. INDICATES EXTERIOR WALL
STUDS SPACED AT 12" O.C. 1.55E
TIMBERSTRAND MATERIAL OR BETTER (2-PLY
TIMBER-STRAND KING STUDS @ EACH SIDE OF
OPENINGS IN WALL).
7. INSTALL DRAFT STOPPING WITHIN FLOOR
SYSTEM PER CODE SECTION 302.12, MIN. 1
2"
GYPSUM BOARD (OR) 3
8" STRUCTURAL BOARD
ADEQUATELY SUPPORTED BY 2X4 MIN.
MATERIAL, PARALLEL WITH FLOOR FRAMING,
SEPARATING AREAS WITH MAXIMUM SPACE OF
1000 SQ.FT.-SEPARATE INTO EQUAL SPACES.
SD
SD
DOOR INFORMATION ::::
1. ALL DOORS TO BE SOLID CORE UNLESS NOTED
OTHERWISE.
2. EXTERIOR DOORS TO BE HOLLOW METAL OR
ALUMINUM DOORS AND FRAMES.
3. PROVIDE 60−MINUTE FIRE−RATED DOORS AT ALL STAIR
ENCLOSURES.
4. PROVIDE LEVER−TYPE HANDLES AT ALL DOORS.
5.
5.1. WASH SINK CLOSET
5.2. OFFICES (2)
6.
6.1. FRONT ENTRANCE DOORS
6.2. SIDE VESTIBULE DOOR
6.3. SIDE PRAYER HALL DOOR
6.4. FUTURE DOOR (VESTIBULE AREA)
6.5. BASEMENT EGRESS DOOR
SQUARE FOOTAGE CALCULATIONS
UNFINISHED SQ. FTG. 3341 SQ.FT.
FINISHED SQ. FTG.3571 SQ.FT.
FINISHED SQ. FTG. 1662 SQ.FT.
TOTAL FINISHED SQ. FTG:5233 SQ.FT.
GRAND TOTAL SQ. FTG: 8574 SQ.FT.
DRAWING TITLE:
5−27−26LOCATION:
PAGE PAGE DESCRIPTION:
L D
LITTFINDESIGN.COM
MLITTFIN @HOTMAIL.COM
320−224−7844
WINSTED, MN
CURRENT
DATE:
REVISION:REV. DATE:ALL PLANS & DESIGNS SHOWN
ARE THE PROPERTY OF LITTFIN
DESIGN. USE OF THESE PLANS
ON ANY OTHER PROJECT/LOT
OTHER THAN NOTED ON THIS
TITLEBLOCK WITHOUT THE
WRITTEN CONSENT OF LITTFIN
DESIGN IS PROHIBITED.
THIS PLAN PROVIDES BUILDING DETAILS FOR A PROJECT TO BE BUILT IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AS WELL AS ANY LOCAL CODES. CONTRACTOR, OWNER, AND/OR TRADES ARE RESPONSIBLE FOR ANY FINES, PENALTIES FOR CODE, ORDINANCE, REGULATION OR BUILDING PROCESS VIOLATIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR OMISSIONS OR ERRORS
MADE DURING DESIGN, BIDDING, OR CONSTRUCTION PHASES. ANY AND ALL SITE REVIEW IS TO BE PERFORMED BY OTHERS SUCH AS THE CONTRACTOR, OWNER, SURVEYOR, OR OTHER TRADES RESPONSIBLE FOR SITE CONDITIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR CONTRACTOR/TRADE ERRORS, UNKNOWN CODE ADJUSTMENTS AT THE TIME OF PLAN CREATION OR CONSTRUCTION.
STRUCTURAL NOTES ADDED 3-6-26
PAGES E1-E3 & BRICK VENEER DETAILS ADDED (D1)5-27-26 A8 SECOND
FLOOR
PLAN
SCALED PRINT @ 24X36
CLOSED TOP
EL. 106'-8"
T.O. BLK.
EL. 106'-8"
T.O. SLAB.
T.O. FTG.
8" R.F. CMU
2x BLOCKING
PREFINISHED
METAL CAP
FLASHING
20x8" CONC.
FOOTING
4x4 STEEL TUBE
W/ BASE PLATE
FINISH
3'
-
6
"
VERTICAL COMPOSITE
1
D8
T.O. BLK.
EL. 106'-8"
T.O. SLAB.
8" R.F. CMU
2x BLOCKING
METAL CAP
PREFINISHED
FLASHING
T.O. BLK.
8" R.F. CMU
T.O. SLAB.
2x BLOCKING
PREFINISHED
METAL CAP
FLASHING
1/2" = 1'-0"
ELEVATIONS - TRASH ENCLOSURE1
DUMPSTER ENCLOSURE
8'-8"8'-8"
8"8"
17'-4"
8"8"
8"8"
8'
-
0
"
8'
-
0
"
17'-4"
3/4" = 1'-0"
FLOOR PLAN - TRASH ENCLOSURE2
DRAWING TITLE:
5−27−26LOCATION:
PAGE PAGE DESCRIPTION:
L D
LITTFINDESIGN.COM
MLITTFIN @HOTMAIL.COM
320−224−7844
WINSTED, MN
CURRENT
DATE:
REVISION:REV. DATE:ALL PLANS & DESIGNS SHOWN
ARE THE PROPERTY OF LITTFIN
DESIGN. USE OF THESE PLANS
ON ANY OTHER PROJECT/LOT
OTHER THAN NOTED ON THIS
TITLEBLOCK WITHOUT THE
WRITTEN CONSENT OF LITTFIN
DESIGN IS PROHIBITED.
THIS PLAN PROVIDES BUILDING DETAILS FOR A PROJECT TO BE BUILT IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AS WELL AS ANY LOCAL CODES. CONTRACTOR, OWNER, AND/OR TRADES ARE RESPONSIBLE FOR ANY FINES, PENALTIES FOR CODE, ORDINANCE, REGULATION OR BUILDING PROCESS VIOLATIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR OMISSIONS OR ERRORS
MADE DURING DESIGN, BIDDING, OR CONSTRUCTION PHASES. ANY AND ALL SITE REVIEW IS TO BE PERFORMED BY OTHERS SUCH AS THE CONTRACTOR, OWNER, SURVEYOR, OR OTHER TRADES RESPONSIBLE FOR SITE CONDITIONS. LITTFIN DESIGN IS NOT RESPONSIBLE FOR CONTRACTOR/TRADE ERRORS, UNKNOWN CODE ADJUSTMENTS AT THE TIME OF PLAN CREATION OR CONSTRUCTION.
STRUCTURAL NOTES ADDED 3-6-26
PAGES E1-E3 & BRICK VENEER DETAILS ADDED (D1)5-27-26 D7 TRASH
ENCLOSURE
DETAILS
SCALED PRINT @ 24X36
1
CITY OF LAKEVILLE
DAKOTA COUNTY, MINNESOTA
CONDITIONAL USE PERMIT
FINDINGS OF FACT AND RECOMMENDATION
On June 25, 2026, the Lakeville Planning Commission met at it’s regularly scheduled meetings
to consider the application of Al Hadi Association for a conditional use permit to allow: 1) a
building expansion of a religious institution in the RS-3, Single Family Residential District,
and 2) to exceed 125% of the minimum parking stalls required by the Zoning Ordinance. The
Planning Commission conducted a public hearing on the application preceded by published
and mailed notice. The applicant was present and the Planning Commission heard testimony
from all interested persons wishing to speak.
1. The property is located in Comprehensive Planning District No. 2, the property is
guided for residential uses, which allows public and quasi-public uses.
2. The property is zoned RS-2, Single Family Residential District.
3. The legal description of the property is:
The South Half of Lot 25, Argonne Farms, Dakota County, Minnesota.
4. Section 11-4-3E of the City of Lakeville Zoning Ordinance provides that a conditional
use permit may not be issued unless certain criteria are satisfied. The criteria and our
findings regarding them are:
Finding: The proposed religious institution is consistent with uses allowed in
residential areas of the City. The building meets the height requirements of the
RS-2 District and the exterior materials requirements for institutional uses,
which is consistent with the policies and provisions of Planning District 2 of the
Comprehensive Land Use Plan.
.
2
Finding: A religious institution in the RS-2 District will be compatible with
existing and future land uses in the area provided compliance with the
stipulations outlined in the conditional use permit.
.
Finding: The proposed religious institution use in the RS-2 District conforms
to the performance standards set forth in the Zoning Ordinance required for a
conditional use permit for the religious institution and additional parking.
Finding: The proposed religious institution use will be served with existing
public services and will not overburden the City’s service capacity.
Finding: Traffic generation from the religious institution use can be
accommodated by Junelle Path.
5. The Planning Commission report dated June 15, 2026 prepared by Kris Jenson,
Planning Manager, is incorporated herein.
June 25, 2026
The Planning Commission recommends that the City Council approve the conditional use
permit conditioned upon compliance with the planning report by Kris Jenson, Planning
Manager, dated June 15, 2026.
LAKEVILLE PLANNING COMMISSION
BY: __________________________
Christine Zimmer, Chair
City of Lakeville
Public Works – Engineering Division
Memorandum
To: Kris Jenson, Planning Manager
Jon Nelson, Assistant City Engineer
McKenzie L. Cafferty, Environmental Resources Manager
Joe Masiarchin, Parks and Recreation Director
Zach Johnson, City Engineer
Tina Goodroad, Community Development Director
Julie Stahl, Finance Director
Dave Mathews, Building Official
June 17, 2026
Al Hadi Association CUP
• Site Plan Review
• Grading and Erosion Control Plan Review
• Utility Plan Review
Al Hadi Association has submitted a site plan application named Al Hadi Association – 17732
Junelle Path. The proposed site plan is located east of and adjacent to Junelle Path and south
of 175th Street. The parent parcel is the South Half of Lot 25, Argonne Farms and is zoned RS-2
(Single Family Residential).
The site plan proposes construction of one parking lot and building on 3.78 acres.
The proposed development will be completed by:
Developer: Al Hadi Association
Engineer/Surveyor: Engineering Design & Surveying
The site consists of an existing homestead, barn, garage, shed and gravel parking lot. The site
generally drains from the east to the west and is bisected by a highpoint on the east side.
Security of $50,000 will be held for the demolition of the existing homestead, garage, and
gravel parking lot and sealing and abandonment of the well.
AALL HHAADDII AASSSSOOCCIIAATTIIOONN CCUUPP SSIITTEE PPLLAANN
JJUUNNEE 1177,, 22002266
PPAAGGEE 22 OOFF 55
The site shall not disturb or remove access from the existing shared access driveway to 17700
Junelle Path.
Junelle Path
Junelle Path is identified as a local street in the City’s Transportation Plan. The site proposes
utilizing and improving one access from Junelle Path.
Private Parking Lot
Development includes the construction of privately owned and maintained parking lot.
Construction traffic access and egress for grading, utility and street construction will be from
Junelle Path.
The City’s Parks, Trails and Open Space Plan does not designate a park within this site.
Development does not include the construction of public trails and sidewalks.
The site is located within subdistricts OL-54300 of the Orchard Lake sanitary sewer district as
identified in the City’s Sanitary Sewer Comprehensive Plan.
No alterations to the existing sanitary sewer service are proposed with the site plan.
Development includes the extension of privately owned and maintained water service.
This site is located within subdistricts OL-045 and OL-045-A2 of the Orchard Lake stormwater
district as identified in the City’s Water and Natural Resources Management Plan.
Development includes the construction of one stormwater management basin, one
underground infiltration basin and one rain garden. Drainage will be directed to the basins to
collect and treat the stormwater runoff generated from the site. The basin will outlet to the
storm sewer system in Junelle Path. The Developer shall sign a stormwater maintenance
AALL HHAADDII AASSSSOOCCIIAATTIIOONN CCUUPP SSIITTEE PPLLAANN
JJUUNNEE 1177,, 22002266
PPAAGGEE 33 OOFF 55
agreement for the stormwater system prior to recording of the site improvement
performance agreement. The stormwater system shall provide water quality treatment,
volume reduction, and rate control of the stormwater runoff generated from the proposed
site improvements. This site shall comply with City Ordinance requirements prior to city
approval of the Site Improvement Performance Agreement (SIPA) and construction
commencing. A stormwater maintenance agreement (SMA) is required with the site.
This site contains greater than one acre of site disturbance and is considered a part of
common development greater than one acre. A National Pollution Discharge Elimination
System General Stormwater Permit for construction activity is required from the Minnesota
Pollution Control Agency for areas exceeding one acre being disturbed by grading.
The site includes the construction of privately owned and maintained storm sewer systems.
Storm sewer will be installed to collect and convey stormwater runoff generated from the lot
to drain off site.
Draintile construction is required in areas of non-granular soils for the parking lot sub-cuts.
Any additional draintile construction, including perimeter draintile required for building
footings, which is deemed necessary during construction shall be the developer’s
responsibility to install and finance.
The site is shown on the Flood Insurance Rate Map (Map No. 27037C0184E; Eff. Date
12/2/2011) as Zone X by the Federal Emergency Management Agency (FEMA). Based on this
designation, there are no areas in the site located within a Special Flood Hazard Area (SFHA),
as determined by FEMA.
A wetland delineation was completed for the site. The wetland delineation identified one
wetland on the site. Future review of the wetland was completed by the wetland delineator
and reviewed by the TEP. The Basin was determined to be incidentally created and was not
historically a wetland. It was determined that the wetland met the requirement for a No-Loss.
A tree preservation inventory was conducted on the west portion of the site and removals
calculated. Trees within the east portion of the site will be retained. Forestry staff must
confirm the final tree removal numbers prior to approval of the SIPA and construction
commencing.
All trees identified for preservation shall be protected with appropriate tree protection
fencing and measures installed prior to, and maintained throughout, construction. Any
preserved trees that are damaged or removed during construction will require replacement in
accordance with the Tree Preservation Ordinance.
AALL HHAADDII AASSSSOOCCIIAATTIIOONN CCUUPP SSIITTEE PPLLAANN
JJUUNNEE 1177,, 22002266
PPAAGGEE 44 OOFF 55
EERROOSSIIOONN CCOONNTTRROOLL
The Developer is responsible for obtaining an MPCA Construction Permit for the site prior to
construction. The permit requires that all erosion and sediment BMPS be clearly outlined in a
site’s SWPPP. No grading can take place on the site until an updated SWPPP is submitted and
approved by the city. Changes made throughout construction must be documented in the
SWPPP.
Additional erosion control measures may be required during construction as deemed
necessary by City staff. Any additional measures required shall be installed and maintained by
the developer.
The MS4 Administration Fee has not been collected on the parent parcel and is due with the
site plan. The developer shall provide construction cost estimates prior to City Council
consideration.
Al Hadi CUP Al Hadi CUP
The Developer shall provide a Letter of Credit as security for the Developer-installed
improvements relating to the site. Construction costs shall be provided by the developers
engineer prior to approval of the SIPA and construction commencing.
Storm Sewer Connection 5,000.00
The Developer shall submit the site plan and construction drawings in an electronic format.
The electronic format shall be in .pdf and either .dwg/.dxf or .shx format.
AALL HHAADDII AASSSSOOCCIIAATTIIOONN CCUUPP SSIITTEE PPLLAANN
JJUUNNEE 1177,, 22002266
PPAAGGEE 55 OOFF 55
The Developer shall also pay a cash fee for City Engineering Administration. The fee for City
Engineering Administration will be based on three percent (3.00%) of the estimated
construction cost, or $7,800.00.
Cash fees shall be collected with the SIPA for the site.
Engineering recommends approval of the site plan, grading and erosion control plan, and
utility plan for Al Hadi Association – 17732 Junelle Path Site Plan, subject to the requirements
and stipulations within this report.