Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LA103711
s PERMIT City of Lakeville Permit Type: Building 20195 Holyoke Ave Permit Number: LA103711 Lakeville, MN 55044 Date Issued: 10/29/2007 (952) 985-4440 www. ci.lakeville.mn.us Site Address: 16369 Elm Creek La Lot: 002 Block: 002 Addition: Fieldstone Creek 3rd Addition PID: 22-26702-020-02 Use: DEA Description: Sub Type: Single Family -All Inclusive Construction Type: V-B Work Type: New Description: CO Required Prior to Occupancy Census Code: 101- 1-Single Family Detach Occupancy: R-2 Zoning: RM-1 Square Feet: 0 Comments' 1----2" METER, PRV, AND MXU PER BUILDING HAS STREET DRAINTILE, FIREPLACE, FIRE SPRINKLER Fee Summary: Descri tp ion Amount Revenue Code Valuation: 120,000.00 1997 UBC Permit Fee $1,105.75 1000-4151 EL -Residential (New) $85.00 1000-4167 ME -Residential (New) $85.00 1000-4154 PL -Residential (New) $85.00 1000-4152 Plan Review $276.44 1000-4170 Res-Sewer Unit $722.00 5600-4570 Res-Water Unit $3,490.00 5500-4560 SAC -Single Family Home $1,675.00 1000-2128 Sewer & Water Install $85.00 1000-4153 Surcharge -Based on Valuation $60.00 1000-2127 Total: $7,669.19 Contractor: -Applicant - ~Wner: DR HORTON INC - MN DR Horton Inc MN 20860 KENBRIDGE CT 20860 Kenbridge Ct Ste 100 LAKEVILLE MN 55044 Lakeville MN 55044 (952) 985-7815 I HEREBY AGREE THAT THIS WORK WILL BE PERFORMED ACCORDING TO: (1) THE APPROVED PLANS & SPECIFICATIONS; (2) THE APPLICABLE CITY ORDINANCES & CODES; AND (3) THE MN STATE BUILDING CODE. A SEPARATE ELECTRICAL PERMIT IS REQUIRED Applicant/Permitee: Signature Issued By: Signature RESIDENTIAL BUILDING PERMIT Office Use only APPLICATION ~ ~ Permit Number f CITY OF LAKEVILLE ~.z BUILD 01915 HO CTIONS DEPARTMENT Received By LYOKE AVENUE c ,E , , LAKEVILLE, MN 55044 ,1i~ ~-~`l~`~1 ~ 952-985-4440 ~ ~ Date Received ~ www.ci.lakeville mn us ~ ~ v ~ i~ - ~ Permit Fee SITE ADDRESS: ~^v~, ~ ~~Y~~~ MAILING ADDRESS: CITY: 4 STATE: ~ y\.~ ZIp:~ ' JOB DESCRIPTION:_ t~="Y~~_~ ~t,~~~~--~~~r ;yes ESTIMATED VALUATION: ~ I ~~a PROPOSED START DATE: E D TE: (New Residential Only): LEGAL DES RIPTION: LOT BLOCK:. SUBDIVISION: `R - s.~t?-e NEW MODEL HOME: ? YES ? NO IF YES -ADMINISTRATIVE PERMIT REQUIRED ISD#: PLEASE FILL OUT THE FOLLOWING COMPLETELY RESIDENT OWNER NAME. HOME PHONE CELL PHONE: GENERAL CONTRACTOR CONTRACTOR: ~ , I~ LICENSE B f I ? Homeowner ? Contractor OFFICE PHONE CELL PHONE: ADDRESS:- CITY: ST: ZIP: ELECTRICAL WORK CONTRACTOR: ~ t LICENSE#: CA ? Homeowner * OFFI . ~ ' CE PHO ? Contractor NE ~ ~ ELL PHONE: * ? Single Meter on individual unit ? Meter Bank @ end of building (Requires licensed elegtreian.) PLUMBING WORK CONTRACTOR: ~'r_~,,_, LICENSE#; PM ? Homeowner ? Contractor OFFICE PHONE ~ R CELL PHONE: ADDRESS: CITY: ST: ZAP: MECHANICAL WORK ~ d CONTRACTOR: ~ ~,i^~..r ? Homeowner ? Contractor OFFICE PHONE ~ CELL PHONE: ADDRESS: CITY: ST: ZIP: SEWER/WATER CONTRACTOR CONTRACTOR: New Construction Only PHONE ~ - ~ , INTEREST EARNINGS ON THE ESCROW ~ ACCOUNTS, IF ANY, ARE RETAINED BY THE CITY TO OFFSET THE ADMNISTRATIVE COSTS ASSOCIATED WITH PROCESSING THE ESCROW APPLICATION AND REFUND. I HEREBY APPLY FOR A BUILDING PERMIT AND I ACKNOWLEDGE THAT THE INFORMATION ABOVE IS COMPLETE AND ACCURATE; THAT THE WORK WILL BE IN CONFORMANCE. WITH THE ORDINANCES AND CODES OF THE CITY AND WITH THE STATE BUILDING CODE, THAT I UNDERSTAND THIS IS NOT A PERMIT AND WORK IS NOT TO START WITHOUT A PERMIT AND THAT THE WORK WILL BE IN ACCORDANCE WITH THE APPROVED PLAN. NAME OF APPLICANT' (Please Print} ~~C~-= a APPLICANT'S SIGNAT i ~ DATE: r~~~~~T~ (Revised 02/22/2006) RESIDENTIAL BUILDING PERMIT APPLICATION PAGE 2 ' OFFICE USE ONLY BUILDING PERMIT TYPE REQUIRED INSPECTIONS SINGLE FAMILY DWELLING (10) BUILDING DUPLEX (20) ~OOTING (60) TOWNHOUSE UNITS (30) ? POURED WALL (86) DETACHED TOWNHOUSE UNITS (35) GARAGES (70) CONDO (40) _S~FOUNDATION (67) ACCESSORY BUILDING (71) F~~ _I~ G 62 ( ) REROOF (73} LATH (64) RESIDE (72) _~FIREPLACE (68) RES ADDN/REPAIR/RMDL (75) ~ _~INSULATION (63) DECK (76) DECK FOOTING (80) PORCH (77) PORCH FOOTING (81) LOWER LEVEL FINISH (78) ~^BUILDING FINAL 90 ( ) ADDITION (79) LOWER LEVEL FRAME (56) FOUNDATION ONLY (96) SITE (71) MISCELLANEOUS (98) OTHER (70) UNDEFINED (99) SEPTIC TANK REMOVAL(77) DEMO (95) MOVED 94 ( ) ELECTRICAL , O 00 n ~_ROUGH-IN 62) G ~ V TRENCH (64) CITY BUILDING VALUATION ? FINAL (65} BUILDING PERMIT FEES MEC CAL $ I / n ~ ~ PERMIT FEE ROUGH-IN 84 ( ) $ 276. PLAN CHECKts p!~ R TEST (69) $ 6 0 - SURCHARGE ~INAL (91) $ 7S~ - METRO SAC $ 9 O CITY WATER HOOKUP UNIT PLUMBING $ 7ZL CITY SEWER HOOKUP UNIT OUGH-IN (83) $ LANDSCAPE ESCROW ~~FINAI, (92) $ TREE ESCROW METER SIZE $ MISC ESCROWPRESSURE REDUCING VALVE $ S -ELECTRICAL $ ~ ~ PLUMBING S + WER AND WATER $ ' ° SEWER & WATER c FINAL (93) $ MECHANICAL STREET DRAINTILE (75) $ OTHER / 9 BUILDING INFORMATION S 7669 ~ TOTAL ~~TYPE OF CONSTRUCTION -Z OCCUPANCY GROUP APPROVED BY: .J~ZONING BUILDING INSPECTOR: DATE: ~O - 2 Z PLUMBING/MECHANICAL INSPECTOR: DATE: U COMMENTS: t _ ~re Sa r; H ~ r to Address ~ ~ ~ ~ ~~1~. i! / - rty ofZake~nIIe ~A~~ ~ ~~~~T ~ ~ ~ %O I95 Holyoke Ave _ ~ L.~keviIIe MN, SSO~i- TWO ~ ~ I3~G~~~ - tUCTIONS: This aiter-natrve may be wed far oue- and two-family dw~Ili.~~s ~1~ :CSI bory i requirements of sofa Rules; chapter 767Q Complete Parts A; B, and C_ CIearly ~¢ark plans. ~a=r. ~,-l:s:~% cu ~ ia~Les; window and skylight U- size and type of equipment; equipment controls; and.Ioc~on of vapor _~:.~:~e: ~s ys-:dwash barrzers_ More detai~Ied ataon can be found in the Minrzesotq F_ner-gy Code cTirrim~ry sheets available from ti:e'~~es~~ L`e~art~ent. of Commerce. . ~raposed envdope joint Sealing .option 3 : - Preseripave (calking>.gasbeLS, etc.} ~ Fe. ~~:r:ance (test per 7670_0470 Subp_ 7_C } " &ermal aaergy calculation cigtion used. ~ Q °Cool.-boot~" {cornplete wodsheet below)- tiinCner metfiod (anach repozt} . . Q .Performance (attach U-value:calculatiorZS} © Systems AaaIysis method. {attach anaIyszs} . - ' - MI2~Ih'v,UJM 12I;~TJIRr 1vIl;IVTS. ~okbook"~",GVo:rks~ee~. - : -_-_°:~fm~=~s;ao~IDOOI~ o sow ouI . - - Q Ceiling Insulation. . itiliuimurn R-38 with 7%" eneergy heel; ar - IrrsrRtrcrlOris - - 1V~tuimum R-44 witfi Iaw tI'[ISS heel; . or ~ . " . Check item(s) that deign meets on 3:firiiruQii.Requiremerrtr Iist NI-inzmum R-38 with R=5 sbeathzri2 when no aruc_ - to the right Must meet aII items to use."CookbooI~' option. ~ - 0 " Entry Doors Max U=~ralue of 030 or I3/"solid wood with storm Indicate proposed wail type on table below. _ C7 Rim Joist 7nsuIalion_ Ivfiniznum R-I 9 - Indicate Wmdow U-value and sources . " Q Floors over ~mconditioned aces Ivfnimurn R-24 Verify total window (inciudiag, area of aII foundation windows}. O Foundation Inszrlarion_ Mnimum R-I O and door areit is equal or Less thaw allowable percentage. . ' O Foundation window;- insulated glass, wood or vinyl frame . TAELE FQIt DE~7Cl?RMINING NIA;XIIVIiTM WIND4'W AND DO©R A-'RFA za Allowable TataL Window and Door Area as - ~ - " - - - - ~ ofEzposed WaII -""I2% ~ - 14% " " I6 % I8 % " 20 l 22 % 24 % " 26%" ~ 28 l _ ndan3 Framin Nfa~amum Average Wmdow IS-value (ex t foundation windows}- R I3 insulation. a R-7 sh~idiia~ OS~ 0.4Z O.4t 036 033- 034 027 0~ 023 R- h iusulation_ ti R-5 siirath~~ OSZ 0_45 039 -0_35 03I - 028 026 024 0?~ _ R- I9 insalaton_ < R-5 sheathing - 0.48 - 0.4I 036 032 - 029 026 024 022 02I 2 I9 iiLRrlafioq 21. R-5 sheatttin OS6 0_48 0.42 037 034 03I 02:i 026 024 EL-2i u~suiatioq <R-5 sfieathin OSI 0_43 038 Q34 - ~ 030 028. 02~ - 013. Q'?~.. 2-2I ins~Iauoq fl. R-5 sheaxhin~ OS8 OSO 0.44. :039 - 035 - 032 - 029 027 025 e (Advanced Framing . ~ Aila~amum ~lveta~e Window Il-value (ecc t foundation windows = t t9 insularioq <R-5 sbculun OS2 - 0_4S - 039 - 035' 031 028 026 024 0?~ I L-19 insulatiocL. t3 R-5 sheattun OS8 " OSO" O_44 " 039 = - 035 032 ~ 029 027. 0~ " '~i C-2I uuuIaaon_ <R-S slieathin - ~ OSS 0.47 0_4I - 036 ~033-~ - 030 -027 0?5 0?3 -?I irrv.LttingljR-5sheathut~ 0_60 0:52 O_46 0_4I- - 036. 033 -_030 028" 026.- Wmdow U-yalu~ Source: Q NFRC Q ASIIRAE I993 Handbook ! - 4 fl ~n^dadu ~n-~ aE~ ?.soss ticposed ~~.I arts.:. DESIGFI ALLOWABLE {from table above} e`a.9 ~ RI;'SL~ ~ ~4,TILD~C - A~I'I.~CAB~.E R~TLES rv ~ r „ins ~ ~sPF.~,Tgs ~ ~t-~--3t~ 7c7?- a= - ~ti 3 ~ ~~.~a~c, I- W~ct ~gr - s,.:I'~ S"T~~--~ }~~i! L~ .-x roZ;1~ 4°L"Z~S.~ a C~-' 7E77y ~_eT`O€'~' I" tr.^a~~'~1t~3to~ Y tit' ?'°SSZPI'u'.•3t-i0II :.I3d VC'?3C3~IyFIQP E..ti:3LT'•..YZY°:S ~s - ~.p~._.~ so~,.,?~o~ses sad ro~2a noses C~~<er7573 e:s°-`C~°~~ry I" cr `€~ate~as ~ provi-moo s l T.~;~~gs of 3 s~~~:s or gas C'n 75 i ~ ~r - eYa~= csi~nonri'~.-=°•*.ms o~ spas-C~se~:rs ~ LI~~=°r 767Ck -.r? eiL~ir "C:~e~ory I" er "C3ie~o; Y ~ravisa?-s Ili r€~~°~cy h::.ild-sus ase: 3 sta~~ Ir~~s~ Chapter 7a?5 - p ?~Iew Iti~ rise co=atlos or apartmea~s ~ ` - F - - _onuse ' . - ~1 ~ P a ? FueI l,tTr~m6 e~'mprent (complete~sc;~zdules below • - - - - _ ? No ~eI burnu~ Equiement 11tiS 1RLCIIONS - . - - ~ - Step I_ Complete e Corr..b~crtzorzE"quiF,z~entSe~edzcle below_ Only equipment ~~XHA~S~'IYL-~~+-~'IP-'A~RS~CI~D{7LE` - ~vitlZ a Y (Yes) may be selected wader the "C~e~ ust devices over 300 cfm Flow _ _ Dory I" a~eaate_ _ _ ~ ~ Step 2_ - Complete ~rizazcst/lYfake-zm ~1 a-<Sc~zedule on the right ii daect or power - - . ventezt or solid fizeI aanosp7seric sent space heatma equipient is seIecced_ ' ~ S~gN~(3PI1'~I`I'~' ;S~k1~17 (-check ail: tapes ro used} - . Spacelzea-~g-AOnsoiidfuel -Bealedcorribustion . ~ Y - He~~ - o ' - - A zzsoltd:friel - - - _ ©_Direct or otiver vezrted - Sealed combus~on ~ y.- . p y~ - Atm ~ hoc.. v - ~ ? Direct or ower.vented y Water hea~nv - eAted N ' ~ . ~ : Atazo ~ hericall Yezrted . nonsohd fuel ? Sealed combustion Y- - • S aee beaiin a -solid fuel ©~-tr~iosoherica.II vented y~ - ? Direct or over vented ' ~ Y _ _ ~z~fer heatznQ _ solid fuel • d A.tuio hericaII vented - = - : ~tm lierica: vented ~ - N~ . Head -°solid. fuel: - Y * If atmospherieaLly vented solicl~f¢~I oz direct or potive~~entedao~olid`.~ue? spacehe~ff - ~ ~ ~Atmo hericaIly vented y is re d far each>ndi~uzduaIeaust deice,which-exce°~ds~~3QfT`cubicfeet:. er~iuute: ~ uish.Iled, tlzez~.make-ap an-to match flow - ~ - ~`IT~.T~o~r QuArr-~Txy ~ ~ . - _(hZechanicai ventzgattan must be provided per the Iarger quantity calculated below) ~ extbic feet x 4_fl(?5$3 /~iunfe = cam. E . - ?olume of habitahle_rooms t x I5 cfru./bedx-uaza) -L IS cif = s cfttt - nwztber of edrooms . ' ~ y'ENfiIL.A.TIOY F~.lY ~~D~~ _ - Sheck methad{s) proposed p E,•~a„~ o~y ~ ~ ~ p 8~~~ ~e~ recovery vent~ator, air exchanger, etc-) an des ~ tion or Iocai~ou ~ ' ~8'NTII,ATION c-'4 v~~__ ~ v r_. .Intake ~ ~ TOT<4I,S 4S DESIGNED Exhaust c~ ~ cfm . . C.ai cfrt ~ L' efm c~ cfrn itatezuent of Compliance= The proposed buildiu~ deli - ~ . .pecifcations, and other cult 5 en represented in these documents is co~s-istent with the buu`dina plans tr7af;ons sabmitied tivith the perrn;t applicaQO~ The ro . osed buildin~- •equiremerrts of the Minnesota Enerw Codz_ p P_. ~ has heen designed to meet the ~pp?FCant_(prmt,~a~e) Si~-u' a , L{ i.~' ~ - t lC,ti" ~ ~ Dat., eiephofie aIIZnber . - . . ~ _ (Subzrtit Paa-z Cz upon camel-eizon of sys#ezn ver~ficatioir~ - r~ r . _ , ob Site Address: an descii~riou orloction Pe~tNumber • ~ASU~,D - ~ 1 4 Iutake c~ I ~ ~ TO TAI,S ERFOF~1~1 ~~i CE ~ I c~, T E~aust : c~ ~ I cfn Venula*_ian zate ~ - chi c'-,,u nzLSt be m°asured and ver~e3 women ~e e, orT~ cm c~ of joists iA tie b::iZdi~a conditioned en~elcpe 11;,m Pzr yF)_ ::ice optLon :s used is Iieu of the presci,;ptive cp~on forme se.~; 'cmplzanee Statesent_ L~ailed veni~I:~~eL svst=-; - - is m c o~pliance T~ztli ti~ i Enemy Code az?C is si=°d - ' - ~ - DDI:C'=-t ~jP~L II~~e~ ~'1~~P_u I i~a I ~ e~LQ1_c' - _ ~ ~ UUb/FIJI ~ELLfAN-T nmECZ~x;K1caL " HEAT LASS ~11~-I~JLi71DN 8sI>LDF~L- 17. !Z H~QR7a7it G2JSTQna HgnaEs 1Qa sr7 I2OOnm_ - II4AIN LE~/~ 'W1NOO-.- INF7LZ T7L3N ANQ ~ - - - NO: WQTf-f ~ f-tGT C1V1_ F'i' AREA . LO . _ - 4_D ZH_B 24.D , . 0 0 0.0 O.CI p D Qf1 ap - QD D.fJ HTG R-~ - a n D D CLC _ ~-Q iNF7LTRA QN-GdA C13EE 8TI3Fi COEf BTUI-f A12~Ji-.G ZU-g - 3~n _ _ gBp.B e.t1 78Q-Q f3OCR5 - ~'D SD.II 7ZOD_II 3fl.D 4720 2.D 3_Q T_Q .Ip-II 4Z4 - - iNF3L-TRA QN-0 t5~- ' : p,II ~ ~RtzEA _ _42D _ - 4Z_D - t9T41T @_5 - RS Z73 0 F.YF _ - _ 4Z-,p ~ij t4;tLt7 ~ H-D 25ZQ T WALL _ 39a-D NL-I''i?tP $EII 11SI - - 37H_D Q-3LtNG'. - - - a 5 ~ ~ 743T-Q -t-1 3a9-S T~OEJR O UN - - ~-II 25 ~g 7 Q - 713 5PACE an ss_n HAS WRLL z'9 D•¢ U_D - OQQ LD_ G - .Q:II 4.5 f7-R t3A5c`~t T WA(.L (J_ S_G„ D-d Q-II D-0 Q D 4.4 0.0 Q_D ~ VItALL B i_ - p II as 'LIMN qN. t? 2E S+]- h7". &420 3'.A QII QII _ 0_Q - MA>rt - PER ER ON Z-7 _ 73481 ¢II - a,o VENTILA QN" - ~ _ 98-II - ' `,79-a g7Z,0 O.Q _ 4 0 FCjJPLE. OA12 - - D-d ¢ II K2TCHQY: OWAN _ II_Q f ATENT Ogt1NG - 7Z[IA-Q NE4T L 5 ~ f~Atk ulatri - - 5585 . ~se_n _ a7aa_s WINCOV _ iNF71„ TtpN AN73 Req. LNL F'T' AREq 6.B ~ - 4-II _ _ _ - 78,D 6Q,1J - Q.d 0_Q . - D,0 O.0 . ' 4D Q-13 Q-0 Q_II _ a.a _ Q~ - tkII O_II n.n a_D NfG HTG CLG _ _ CLG - tNRLTRA q - U-D QD CDEF BTTiH Ct1EEi= 6NN TaD 35.D ~T3Cl.II g Q . ARE,4 - 6 S 4E8 0 DOORS C II6.A SQ_II 3DQD_B 39~ 22eU_t7 Z_d 3-II 70 4a.g q~ - - - - II-a ' ¢u - _ Il~SFILT}ZA ION-pO0 S. Rr'aEA -Q QRS az-D d7.II 7974.4 G_5 ' 273,D E:iPOSRGQ WALY, 42Q ~-II _ 1-f7iF_II . - 6Q - ~p ~ t'tET E-'KFt~tSL-~S WA - _ - - 2B8_II - . ~ . !CEILING 213x,6 iFLQOR d ER LiNCO O:PACE OIIO.O 23 7?D9.4. 1`D B3tJ_D` ~BASc. TWALL 245_D ?:3 718.7 6-a - - ' 13 LO_ A G_ Q-II DA _I~r II_II _ QII - BA&E3ttIE1<TWALL a H_C~. _ - - II-o Q-B 4_4~ Q-.Q D.Q 8A5 T WALL _ g.a BASFIt,I T FtQQR SQ f`T 3_s RII p p D_Q BaScitilEitiTPERI 4N a'ff 27 QQ 0.0 E 1.NZ - ~ _ O.iS - JEiyTIE.,a; D-0 7J_U D:D . p_p - (1.4 FLOPts UOAO - a~ 729_~J ~aTExar oOtlt~G - a~ ~EaTLG' a GA7lY U~~xE~ - ~ 7£ri7_Q iERT LO55 S GAIN y Aftd ~ iIF3~EFF ~ 789755'- _ - 84II7.6 Zfi171.S 71HS6_H . aLUANTnnECHaN1ca1` HEAT L033 CALCULATION BUILDER: O_ R. NORTON G115TOM HOLIES J09 57T>`" ROOM: MAIN LEVEL WINDOW - INF1L T10N RN0 REA NO. WDTH NGT _ _ WL FT AREA 20 3.0 5.6 34`6 ~-0 1.0 6.0 7.5 15.0 9.0 1.0 3.0 7.0 20.0 _ 21.6 o_a a.o _ _ - o.o as HTG rife cLG cLG 0.0 0.0 COEF BTUFt COEF eTuN 88.8 35.0 Za15.0 8.0 a-ta,0 1NFILTRn 10N-&LA - AREA - G S 01.6 50.0 3156.0 T 38.0 2384.0 DOORS - 3-0 3.L1 _ 7.D B1JA 53.0 _ 0.0 D.0 _ 1NFiLTRA ION-DOO` S ~ ~-0 ~17_D 2881.0 6.5 009.5 AREA - D ORS - - S3.D 35.6 2205.0 6.0 - 179.6 CXPOS WALL S86.D - NET EXP SED WA - 570.6 A_5 2565.0 t4 62'r_0 CEILING - ~ 178.0 23 468.4 - tD 17$_0 FLOOR O CR UNCO D SPACE II.0 Z9 0-0 0•D D-D BASEME WALL OOD LO. A_ _ 0.0 4.6 _ D_D D.D D-D 6AS1=ONE WaC1. L. . ti.G. D.0 4.4 D_D - 0.0 ^ D-D BaSL-1+nE WALL B_ _ 0_D 3.9 t1.0 - 0 0 0 6 885:0 21 1398,5 D.D o.0 MA1N L LONG DE Sta FT { _ Ma1N LG PERIM R ON G DE LNL - 67.6' '19.6 1853.8 0.0 oA vENTriAT ON - D n D.o D.0 PEOPLE D . - - 12648 KfTCHEN LLOWAN E - 1688.2 LATENT DUNG HEAT LO 5 ~ CAIN:=1srtnlN LEVE 16754.9 7290.7 ROONt_ UPPER LEVEL _ WINDOWS - INFJLT TION ANII REA NO. WBTH ~ HGT^~ LNL.FT. AREA 20 3,Q 4.0 2H.0 24A ~ • ; o_o D_D - - _ 0 D a-D HTG HTG CLG CLG ~O.D _ 4__0 COEF BTUH COEF BTUN INFILTRA lON-GLASS 80,0 ~ 35.0 2800.0 8A . Sao 0 AREA - G SS ea,o r. 60.0 3206.6 38.0 209^_0 DOORS 3.0 7.0 D.0 0-Q - _ _ - INFILTRA ON-000 S D_D 47.0 QD 8.3 r 0.0 AREA - O ORS D.o 35.0 0_D 6.0 0.0 CXPOSR WALL - 5120 Nt=f EXP SED WA 449_{) A_5 201&0 T_1 dIIZB CEIUNG - - 773.0 29 1777.9 _19 773.0 FLOOR O ER UNCO D SPACE 2920 Z9 956.5 09 D_0 SASEME WALL 000 LO_ A _ 0.0 ' 4.5 D:D D.0 D_0 6A5EME WALL L . B:G_ 0.0 4_a r _ 0_D 48 D:D. BASEME WALL 6.~- U_D 3_B D.D D_D (}-0 BASEMCNT FLOOR OFT D.a 2Y a,8 _ 0.0 0-D BASEMEN PER1M Eft ON GRA E LNL 40 19.0 0.8 0.0 8-8 YENTILA ON 1 427&:8 729.0 . 1266.0 PEOPLE DAL] _ - 0.0 r EQTCHEN LLOWAN E _ 1832.6 LATENT OUNG --7939.6 HEAT LO S & t;,AIN UPPER L ~1. 1497_7_Z . HEAT LO 3 & GAiN, AIN & UPP R LEVEL 11E9Z'f ~ 16218.5 J _ f